LC-PHYSICAL-ENTITIES-MIB

File: LC-PHYSICAL-ENTITIES-MIB.mib (58061 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC LANCAST-MIB

Imported symbols

MODULE-IDENTITY OBJECT-TYPE NOTIFICATION-TYPE
Integer32 DisplayString lancastMibModulesA
lancastTraps

Defined Types

ChassisTableEntry  
SEQUENCE    
  chassisEntityIndex Integer32
  chassisDescription DisplayString
  chassisPartNumber DisplayString
  chassisNumSlots Integer32
  chassisCurrentTemp Integer32
  chassisMaxTemp Integer32
  chassisReset INTEGER
  lastEntityResetReason INTEGER
  lastEntityResetIndex Integer32
  lastEntityResetTime DisplayString
  lastEntityResetType INTEGER

BackPlaneTableEntry  
SEQUENCE    
  backPlaneEntityIndex Integer32
  backPlaneDescription DisplayString
  backPlanePartNumber DisplayString
  backPlaneSerialNumber DisplayString
  backPlaneManufactureDate DisplayString
  backPlaneHWRevisionNumber DisplayString

PowerSupplyTableEntry  
SEQUENCE    
  powerSupplyEntityIndex Integer32
  powerSupplyStatus INTEGER
  powerSupplyType INTEGER
  powerSupply5vCurrent Integer32
  powerSupply5vMin Integer32
  powerSupply5vMax Integer32
  powerSupplyUnitIdentifier INTEGER

ModuleTableEntry  
SEQUENCE    
  modEntityIndex Integer32
  modAdminState INTEGER
  modOperStatus INTEGER
  modType INTEGER
  modDescription DisplayString
  modName DisplayString
  modPartNumber DisplayString
  modSerialNumber DisplayString
  modManufactureDate DisplayString
  modDiagnosticTestStatus DisplayString
  modHWRevisionNumber DisplayString
  modNumPorts Integer32
  modFirstSlot Integer32
  modNumSlotsOccupied Integer32
  modReset INTEGER

MgmntTableEntry  
SEQUENCE    
  mgmntEntityIndex Integer32
  mgmntBootImageName DisplayString
  mgmntBootImageVersion DisplayString
  mgmntCoreImageName DisplayString
  mgmntCoreImageVersion DisplayString
  mgmntAppImageName DisplayString
  mgmntAppImageVersion DisplayString
  mgmntRamMemorySize Integer32
  mgmntFlashMemorySize Integer32
  mgmntNVRamMemorySize Integer32
  mgmnt5vCurrent Integer32
  mgmnt5vMin Integer32
  mgmnt5vMax Integer32
  mgmnt3pt3vCurrent Integer32
  mgmnt3pt3vMin Integer32
  mgmnt3pt3vMax Integer32
  mgmntDiagnosticBootError INTEGER

SingleTwisterTableEntry  
SEQUENCE    
  stwEntityIndex Integer32
  stwLinkLossCarryForward INTEGER

DualTwisterTableEntry  
SEQUENCE    
  dtwEntityIndex Integer32
  dtwLinkLossCarryForward INTEGER

RedundantTwisterTableEntry  
SEQUENCE    
  rtwEntityIndex Integer32
  rtwAutoRestorePrimary INTEGER
  rtwLinkLossCarryForward INTEGER
  rtwActivePort INTEGER
  rtwRedundantTransmission INTEGER
  rtwSecondarySwitchOver INTEGER
  rtwLinkPulseControl INTEGER
  rtwModeControl INTEGER
  rtwABSelect INTEGER

EPortTableEntry  
SEQUENCE    
  ePortEntityIndex Integer32
  ePortIfIndex Integer32
  ePortType INTEGER
  ePortDescription DisplayString
  ePortName DisplayString
  ePortLinkStatus INTEGER
  ePortAdminState INTEGER
  ePortOperStatus INTEGER
  ePortDuplexAdmin INTEGER
  ePortDuplexOper INTEGER
  ePortSpeedAdmin INTEGER
  ePortSpeedOper INTEGER
  ePortAutoNegotiationAdmin INTEGER
  ePortAutoNegotiationOper INTEGER
  ePortReset INTEGER
  ePortActivity INTEGER
  ePortConnector INTEGER
  ePortParentRelPos Integer32

SerialPortTableEntry  
SEQUENCE    
  serialPortEntityIndex Integer32
  serialPortDescription DisplayString
  serialPortName DisplayString
  serialPortSpeed INTEGER
  serialPortDataBits INTEGER
  serialPortParity INTEGER
  serialPortStopBits INTEGER
  serialPortFlowControl INTEGER
  serialPortConnector INTEGER

Defined Values

physicalEntities 1.3.6.1.4.1.2745.1.2
This is the enterprise MIB definition file for the Physical Entities of Lancast Managed products. Copyright 1999 Lancast Inc.
MODULE-IDENTITY    

chassisGroup 1.3.6.1.4.1.2745.1.2.2
OBJECT IDENTIFIER    

backPlaneGroup 1.3.6.1.4.1.2745.1.2.3
OBJECT IDENTIFIER    

powerSupplyGroup 1.3.6.1.4.1.2745.1.2.4
OBJECT IDENTIFIER    

modulesGroup 1.3.6.1.4.1.2745.1.2.5
OBJECT IDENTIFIER    

ePortGroup 1.3.6.1.4.1.2745.1.2.6
OBJECT IDENTIFIER    

serialPortGroup 1.3.6.1.4.1.2745.1.2.7
OBJECT IDENTIFIER    

chassisTable 1.3.6.1.4.1.2745.1.2.2.1
A table of relevent information pertaining to each chassis contained within this system.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ChassisTableEntry

chassisTableEntry 1.3.6.1.4.1.2745.1.2.2.1.1
An entry in the table, containing relevant information about a specific chassis contained within this system.
Status: current Access: not-accessible
OBJECT-TYPE    
  ChassisTableEntry  

chassisEntityIndex 1.3.6.1.4.1.2745.1.2.2.1.1.1
A unique value, the entPhysicalIndex from the entity MIB, which identifies this chassis.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

chassisDescription 1.3.6.1.4.1.2745.1.2.2.1.1.2
A textual string describing a chassis contained within this system.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..64)  

chassisPartNumber 1.3.6.1.4.1.2745.1.2.2.1.1.3
A textual string of the part number assigned to this chassis.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..64)  

chassisNumSlots 1.3.6.1.4.1.2745.1.2.2.1.1.4
The number of I/O slots that this chassis supports.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

chassisCurrentTemp 1.3.6.1.4.1.2745.1.2.2.1.1.5
The temperature of this chassis measured in Celcius degrees. This object will be contained in the tempStatusChange trap,
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

chassisMaxTemp 1.3.6.1.4.1.2745.1.2.2.1.1.6
The maximum temperature for this chassis. If this temperature is exceeded failures may result. This object will be contained in the tempStatusChange Trap,
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

chassisReset 1.3.6.1.4.1.2745.1.2.2.1.1.7
The trigger to reset this chassis. If the design of this chassis does not include this feature then this object will default to not-resetable and no sets to this object will be allowed. If the design does permit a reset then the only valid state that a user can set this object to is is reset. A read of this object will return either resetable or not-resetable.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER reset(1), resetable(2), not-resetable(3)  

lastEntityResetReason 1.3.6.1.4.1.2745.1.2.2.1.1.8
This object specifies the reason the last reset was applied. This object is included in the entityResetTrap pdu.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER cold-start(1), nms-sw-reset(2), download-reset(3), watch-dog-timeout(4)  

lastEntityResetIndex 1.3.6.1.4.1.2745.1.2.2.1.1.9
This object specifies the physical entity index, entPhysicalIndex from the entity MIB, of the last entity that was reset. This object is included in the entityResetTrap pdu.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

lastEntityResetTime 1.3.6.1.4.1.2745.1.2.2.1.1.10
This object specifies the time the last reset was applied to an entity. This object is included in the entityResetTrap pdu.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..64)  

lastEntityResetType 1.3.6.1.4.1.2745.1.2.2.1.1.11
This object specifies the type of entity that was last reset. The values are are a subset from the entity mib entPhysicalClass object.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER chassis(3), module(9), port(10)  

backPlaneTable 1.3.6.1.4.1.2745.1.2.3.1
A table of relevent information pertaining to a backplane contained within this system.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    BackPlaneTableEntry

backPlaneTableEntry 1.3.6.1.4.1.2745.1.2.3.1.1
An entry in the table, containing relevant information about a specific backplane contained within this system.
Status: current Access: not-accessible
OBJECT-TYPE    
  BackPlaneTableEntry  

backPlaneEntityIndex 1.3.6.1.4.1.2745.1.2.3.1.1.1
A unique value, the entPhysicalIndex from the entity MIB, that identifies a back plane for which this entry contains information.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

backPlaneDescription 1.3.6.1.4.1.2745.1.2.3.1.1.2
A textual string describing a backPlane contained within this system.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..64)  

backPlanePartNumber 1.3.6.1.4.1.2745.1.2.3.1.1.3
A textual string of the part number of this back plane.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..64)  

backPlaneSerialNumber 1.3.6.1.4.1.2745.1.2.3.1.1.4
A textual string of the serial number of this back plane.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..64)  

backPlaneManufactureDate 1.3.6.1.4.1.2745.1.2.3.1.1.5
A textual string of the manufacture date of this back plane.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..64)  

backPlaneHWRevisionNumber 1.3.6.1.4.1.2745.1.2.3.1.1.6
A textual string of the hardware revision date of this back plane.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..64)  

powerSupplyTable 1.3.6.1.4.1.2745.1.2.4.1
A table of relevent information pertaining to a backplane contained within this system.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PowerSupplyTableEntry

powerSupplyTableEntry 1.3.6.1.4.1.2745.1.2.4.1.1
An entry in the table, containing relevant information about a specific backplane contained within this system.
Status: current Access: not-accessible
OBJECT-TYPE    
  PowerSupplyTableEntry  

powerSupplyEntityIndex 1.3.6.1.4.1.2745.1.2.4.1.1.1
A unique value, the entPhysicalIndex from the entity MIB, that identifies a power supply for which this entry contains information.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

powerSupplyStatus 1.3.6.1.4.1.2745.1.2.4.1.1.2
The on off state of this power supply.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2)  

powerSupplyType 1.3.6.1.4.1.2745.1.2.4.1.1.3
The type of this power supply.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER ac(1), dc(2), universal(3)  

powerSupply5vCurrent 1.3.6.1.4.1.2745.1.2.4.1.1.4
The actual voltage level of this 5 volt supply as measured in millivolts.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

powerSupply5vMin 1.3.6.1.4.1.2745.1.2.4.1.1.5
The minimum operating voltage level of this 5 volt supply, measured in millivolts.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

powerSupply5vMax 1.3.6.1.4.1.2745.1.2.4.1.1.6
The maximum operating voltage level of this 5 volt supply, measured in millivolts.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

powerSupplyUnitIdentifier 1.3.6.1.4.1.2745.1.2.4.1.1.7
The identifier of this supply.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER ps-A(1), ps-B(2)  

moduleTable 1.3.6.1.4.1.2745.1.2.5.1
A table of common information relevent to modules within this system.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ModuleTableEntry

moduleTableEntry 1.3.6.1.4.1.2745.1.2.5.1.1
An entry in the common module information table.
Status: current Access: not-accessible
OBJECT-TYPE    
  ModuleTableEntry  

modEntityIndex 1.3.6.1.4.1.2745.1.2.5.1.1.1
A unique value, entPhysicalIndex from the entity MIB, that identifies a module for which this entry contains information.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

modAdminState 1.3.6.1.4.1.2745.1.2.5.1.1.2
The desired state of up or down of this module. If the design of this module does not include the abiltiy to control this module then this object will default to not-applicable and no sets to this object will be allowed. If the design does permit control then up and down are the valid states that a user can set this object to.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER not-applicable(0), up(1), down(2)  

modOperStatus 1.3.6.1.4.1.2745.1.2.5.1.1.3
The current operational (up/down) state of this module.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER up(1), down(2)  

modType 1.3.6.1.4.1.2745.1.2.5.1.1.4
The type of module resident in this system.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), reserved(2), mgmnt(3), singleTwister(4), dualTwister(5), redundantTwister(6), displayModule(7), singleTwister2(8), fixedPort(9), rateAdapter(10), gigabitTwister(11)  

modDescription 1.3.6.1.4.1.2745.1.2.5.1.1.5
A textual description of this type of module.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..64)  

modName 1.3.6.1.4.1.2745.1.2.5.1.1.6
A user defined name for this module.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..64)  

modPartNumber 1.3.6.1.4.1.2745.1.2.5.1.1.7
A textual string identifying the part number of this module.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..64)  

modSerialNumber 1.3.6.1.4.1.2745.1.2.5.1.1.8
A textual string identifying the serieal number of this module.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..64)  

modManufactureDate 1.3.6.1.4.1.2745.1.2.5.1.1.9
A textual string identifying the date that this module was manufactured.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..64)  

modDiagnosticTestStatus 1.3.6.1.4.1.2745.1.2.5.1.1.10
A textual string indicating the status of the last diagnostic test performed on this module including the date and time.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..64)  

modHWRevisionNumber 1.3.6.1.4.1.2745.1.2.5.1.1.11
A textual string identifying the hardware revision number of this module.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..64)  

modNumPorts 1.3.6.1.4.1.2745.1.2.5.1.1.12
The number of ports conntained within this module.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

modFirstSlot 1.3.6.1.4.1.2745.1.2.5.1.1.13
The first slot which is the leftmost slot that this module physically resides in.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

modNumSlotsOccupied 1.3.6.1.4.1.2745.1.2.5.1.1.14
The total number of slots that this module physically occupies.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

modReset 1.3.6.1.4.1.2745.1.2.5.1.1.15
The trigger to reset this module. If the design of this module does not include this feature then this object will default to not-resetable and no sets to this object will be allowed. If the design does permit a reset then the only valid state that a user can set this object to is is reset. A read of this object will return either resetable or not-resetable.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER reset(1), resetable(2), not-resetable(3)  

mgmntTable 1.3.6.1.4.1.2745.1.2.5.2
A table of information common to management modules within this system.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MgmntTableEntry

mgmntTableEntry 1.3.6.1.4.1.2745.1.2.5.2.1
An entry in the managment module information table.
Status: current Access: not-accessible
OBJECT-TYPE    
  MgmntTableEntry  

mgmntEntityIndex 1.3.6.1.4.1.2745.1.2.5.2.1.1
A unique value, the entPhysicalIndex from the entity MIB, that identifies a managemnt module for which this entry contains information.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

mgmntBootImageName 1.3.6.1.4.1.2745.1.2.5.2.1.2
A textual description of the name of the Boot image.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..64)  

mgmntBootImageVersion 1.3.6.1.4.1.2745.1.2.5.2.1.3
A textual description of the version of the Boot image The vesion will include the time and date of the build.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..64)  

mgmntCoreImageName 1.3.6.1.4.1.2745.1.2.5.2.1.4
A textual description of the name of the Core image.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..64)  

mgmntCoreImageVersion 1.3.6.1.4.1.2745.1.2.5.2.1.5
A textual description of the version of the Core image The vesion will include the time and date of the build.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..64)  

mgmntAppImageName 1.3.6.1.4.1.2745.1.2.5.2.1.6
A textual description of the name of the Application (personality) image.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..64)  

mgmntAppImageVersion 1.3.6.1.4.1.2745.1.2.5.2.1.7
A textual description of the version of the Application (personality) image. The vesion will include the time and date of the build.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..64)  

mgmntRamMemorySize 1.3.6.1.4.1.2745.1.2.5.2.1.8
The size of RAM memory measured in number of bytes.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

mgmntFlashMemorySize 1.3.6.1.4.1.2745.1.2.5.2.1.9
The size of Flash memory measured in number of bytes.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

mgmntNVRamMemorySize 1.3.6.1.4.1.2745.1.2.5.2.1.10
The size of Non Volatile Ram memory measured in number of bytes.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

mgmnt5vCurrent 1.3.6.1.4.1.2745.1.2.5.2.1.11
The actual voltage level of this 3.3 volt input as measured in millivolts.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

mgmnt5vMin 1.3.6.1.4.1.2745.1.2.5.2.1.12
The minimum operating voltage level of this 5 volt input, measured in millivolts.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

mgmnt5vMax 1.3.6.1.4.1.2745.1.2.5.2.1.13
The maximum operating voltage level of this 5 volt input, measured in millivolts.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

mgmnt3pt3vCurrent 1.3.6.1.4.1.2745.1.2.5.2.1.14
The actual voltage level of this 3.3 volt input as measured in millivolts.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

mgmnt3pt3vMin 1.3.6.1.4.1.2745.1.2.5.2.1.15
The minimum operating voltage level of this 3.3 volt input, measured in millivolts.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

mgmnt3pt3vMax 1.3.6.1.4.1.2745.1.2.5.2.1.16
The maximum operating voltage level of this 3.3 volt input, measured in millivolts.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

mgmntDiagnosticBootError 1.3.6.1.4.1.2745.1.2.5.2.1.17
This object indicates the status of the diagnostic boot tests. An error is indicated by turning the error indicator on the management module is on.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER on(1), off(2)  

singleTwisterTable 1.3.6.1.4.1.2745.1.2.5.3
A table of information common to single twister modules.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SingleTwisterTableEntry

singleTwisterTableEntry 1.3.6.1.4.1.2745.1.2.5.3.1
An entry in the single Twister table of information.
Status: current Access: not-accessible
OBJECT-TYPE    
  SingleTwisterTableEntry  

stwEntityIndex 1.3.6.1.4.1.2745.1.2.5.3.1.1
A unique value, the entPhysicalIndex from the entity MIB, that identifies a single twister module for which this entry contains information.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

stwLinkLossCarryForward 1.3.6.1.4.1.2745.1.2.5.3.1.2
The ability of an input port to forward the link test pulse to its output port. If disabled the output port will always generate link pulses, regardless of input port link status.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

dualTwisterTable 1.3.6.1.4.1.2745.1.2.5.4
A table of information common to dual twister modules.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DualTwisterTableEntry

dualTwisterTableEntry 1.3.6.1.4.1.2745.1.2.5.4.1
An entry in the dual Twister table of information.
Status: current Access: not-accessible
OBJECT-TYPE    
  DualTwisterTableEntry  

dtwEntityIndex 1.3.6.1.4.1.2745.1.2.5.4.1.1
A unique value, the entPhysicalIndex from the entity MIB, that identifies a dual twister module for which this entry contains information.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

dtwLinkLossCarryForward 1.3.6.1.4.1.2745.1.2.5.4.1.2
The ability of an input port to forward the link test pulse to its output port. If disabled the output port will always generate link pulses, regardless of input port link status.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

redundantTwisterTable 1.3.6.1.4.1.2745.1.2.5.5
A table of information common to redundant twister modules.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    RedundantTwisterTableEntry

redundantTwisterTableEntry 1.3.6.1.4.1.2745.1.2.5.5.1
An entry in the table containing redundant twister information.
Status: current Access: not-accessible
OBJECT-TYPE    
  RedundantTwisterTableEntry  

rtwEntityIndex 1.3.6.1.4.1.2745.1.2.5.5.1.1
A unique value, the entPhysicalIndex from the entity MIB, that identifies a redundant twister module for which this entry contains information.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

rtwAutoRestorePrimary 1.3.6.1.4.1.2745.1.2.5.5.1.2
This object controls the ability to perform auto restoration back to the primary circuit if a secondary switchover had previously occurred. When rtwModeControl is selectAB then this object is not selectable and a read of this value will always return not selectable.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2), not-selectable(3)  

rtwLinkLossCarryForward 1.3.6.1.4.1.2745.1.2.5.5.1.3
The ability of an input port to forward the link test pulse to its output port. If disabled the output port will always generate link pulses, regardless of input port link status.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

rtwActivePort 1.3.6.1.4.1.2745.1.2.5.5.1.4
This object reflects the port that is both receiving and transmitting packets. If the active port is the secondary then the secondary led indicator will be turned on.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER primary(1), secondary(2)  

rtwRedundantTransmission 1.3.6.1.4.1.2745.1.2.5.5.1.5
The ability of the primary and secondary output ports to transmit the received main input signal simultaneously. When rtwModeControl is selectAB then this object is not selectable and a read of this value will always return not-applicable.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER not-applicable(0), enable(1), disable(2)  

rtwSecondarySwitchOver 1.3.6.1.4.1.2745.1.2.5.5.1.6
This object reflects whether an automatic switch from the primary port to the secondary port has taken place.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

rtwLinkPulseControl 1.3.6.1.4.1.2745.1.2.5.5.1.7
This object controls the forwarding of the link test pulse to both the primary and secondary ports or the slected port in rtwActivePort. When rtwModeControl is selectAB then this object is not selectable and a read of this value will always return not-applicable.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER not-applicable(0), both-ports(1), active-port(2)  

rtwModeControl 1.3.6.1.4.1.2745.1.2.5.5.1.8
This objects selects the operational mode. Redundant mode provides automatic switchover for port failure redundancy while ABSelect provides a basic A/B port selector.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER redundant(1), selectAB(2)  

rtwABSelect 1.3.6.1.4.1.2745.1.2.5.5.1.9
This object selects the output port that will send and receive packets. If the design of this module does not include the abiltiy to select the mode, then this object will default to not-selectable and no sets to this object will be allowed.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER selectA(1), selectB(2), not-selectable(3)  

ePortTable 1.3.6.1.4.1.2745.1.2.6.1
A table of relevant information about the ports(s) contained within a module.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    EPortTableEntry

ePortTableEntry 1.3.6.1.4.1.2745.1.2.6.1.1
An entry in the table containing port related information within a module.
Status: current Access: not-accessible
OBJECT-TYPE    
  EPortTableEntry  

ePortEntityIndex 1.3.6.1.4.1.2745.1.2.6.1.1.1
A unique value, the entPhysicalIndex from the entity MIB, that identifies a port for which this entry contains information.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ePortIfIndex 1.3.6.1.4.1.2745.1.2.6.1.1.2
A unique identifier indicating the MIB-II interface number of this port. NOTE: ports on media translators DO NOT conform to MIB-II definition of an interface.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

ePortType 1.3.6.1.4.1.2745.1.2.6.1.1.3
A unique value that identifies the type of port. Included in the port type is the maximum speed at which this port may operate at and the cable type.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER other(1), e10BaseT(2), e10BaseFL-MM(3), e10BaseFL-SM(4), e100BaseTX(5), e100BaseFX-MM(6), e100BaseFX-SM(7), e10-100Base-TX(8), e1000Base-LX(9), e1000Base-SX(10), e1000Base-FX(11), e10Base-SX(12), e100Base-SX(13)  

ePortDescription 1.3.6.1.4.1.2745.1.2.6.1.1.4
A textual description of this type of port.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..64)  

ePortName 1.3.6.1.4.1.2745.1.2.6.1.1.5
The user defined name of this port.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..64)  

ePortLinkStatus 1.3.6.1.4.1.2745.1.2.6.1.1.6
The link status of this port. This status indicates the reception of link test pulse signals generated from an attached device. This object is used in the ePortLinkStatusChangeTrap.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER link-detected(1), no-link(2)  

ePortAdminState 1.3.6.1.4.1.2745.1.2.6.1.1.7
The desired state of this port. If the design of this module does not include the abiltiy to control this port then this object will default to not-applicable and no sets to this object will be allowed. If the design does permit control then enable and disable are the only valid states that a user can set this object to. This object is used in the PortControlTrap.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER not-applicable(0), enable(1), disable(2)  

ePortOperStatus 1.3.6.1.4.1.2745.1.2.6.1.1.8
This object indicates the current operational state of this port.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

ePortDuplexAdmin 1.3.6.1.4.1.2745.1.2.6.1.1.9
This object specifies the desired state of half or full duplex mode for this port. If the design of this module does not include the ability to select duplex, then this object will default to not-applicable and no sets to this object will be allowed. If the design does permit duplex selection then half and full are the valid states that a user can set this object to.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER not-applicable(0), half(1), full(2)  

ePortDuplexOper 1.3.6.1.4.1.2745.1.2.6.1.1.10
This object indicates the current duplex mode of this port.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER half(1), full(2)  

ePortSpeedAdmin 1.3.6.1.4.1.2745.1.2.6.1.1.11
This object indicates the current speed that this port is operating at. If the design of this module does not include the abiltiy to control the speed of this then this object will default to not-applicable and no sets to this object will be allowed. If the design does permit control then all but not-applicable are valid states that a user can set this object to.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER not-applicable(0), tenMbit(1), onehundredMbit(2), gigabit(3)  

ePortSpeedOper 1.3.6.1.4.1.2745.1.2.6.1.1.12
This object specifies the desired speed that this port is operating at.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER tenMbit(1), onehundredMbit(2), gigabit(3)  

ePortAutoNegotiationAdmin 1.3.6.1.4.1.2745.1.2.6.1.1.13
This object indicates the current state of auto negotiation for this port. If the design of this module does not include the ability to select auto negotiation, then this object will default to not-applicable and no sets to this object will be allowed. If the design does permit auto negotiation selection then all but not-applicable are valid states that a user can set this object to.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER not-applicable(0), enable(1), disable(2)  

ePortAutoNegotiationOper 1.3.6.1.4.1.2745.1.2.6.1.1.14
This object specifices the desired state of auto negotiation selection. If enabled, this port is capable of auto negotiating full/half duplex and port speed selection.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER enable(1), disable(2)  

ePortReset 1.3.6.1.4.1.2745.1.2.6.1.1.15
The trigger to reset this port. If the design of this module does not include this feature then this object will default to not-resetable and no sets to this object will be allowed. If the design does permit a reset then the only valid state that a user can set this object to is is reset. A read of this object will return either resetable or not-resetable.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER reset(1), resetable(2), not-resetable(3)  

ePortActivity 1.3.6.1.4.1.2745.1.2.6.1.1.16
This object indicates data reception and transmision activity on the active port(s).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER inactive(1), active(2)  

ePortConnector 1.3.6.1.4.1.2745.1.2.6.1.1.17
This object indicates the connector type that this port supports.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER other(1), rj11(2), rj21(3), rj45(4), bnc(5), sc(6), st(7), sma(8), mt-rj(9), vf-45(10)  

ePortParentRelPos 1.3.6.1.4.1.2745.1.2.6.1.1.18
This object indicates this ports relative position in the module to which it is member of.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

serialPortTable 1.3.6.1.4.1.2745.1.2.7.1
A table of relevent information pertaining to each serial port contained within this system.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SerialPortTableEntry

serialPortTableEntry 1.3.6.1.4.1.2745.1.2.7.1.1
An entry in the table, containing relevant information about a specific serial port contained within this system.
Status: current Access: not-accessible
OBJECT-TYPE    
  SerialPortTableEntry  

serialPortEntityIndex 1.3.6.1.4.1.2745.1.2.7.1.1.1
A unique value, the entPhysicalIndex from the entity MIB, which identifies this serial port.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

serialPortDescription 1.3.6.1.4.1.2745.1.2.7.1.1.2
A textual description of this type of port.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(1..64)  

serialPortName 1.3.6.1.4.1.2745.1.2.7.1.1.3
The user defined name of this port.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..64)  

serialPortSpeed 1.3.6.1.4.1.2745.1.2.7.1.1.4
The speed that this port transmits and receives at.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER baud-9600(9600), baud-19200(19200), baud-38400(38400)  

serialPortDataBits 1.3.6.1.4.1.2745.1.2.7.1.1.5
The number of bits in a character.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER five(5), six(6), seven(7), eight(8)  

serialPortParity 1.3.6.1.4.1.2745.1.2.7.1.1.6
The port's sense of a character parity bit.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(1), even(2), odd(3), mark(4), space(5)  

serialPortStopBits 1.3.6.1.4.1.2745.1.2.7.1.1.7
The number of stop bits for this port.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER one(1), one-five(2), two(3)  

serialPortFlowControl 1.3.6.1.4.1.2745.1.2.7.1.1.8
The type of flow control for this port.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(1), xon-xoff(2), hardware(3)  

serialPortConnector 1.3.6.1.4.1.2745.1.2.7.1.1.9
This object indicates the connector type that this port supports.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER db9(1), db25(2), rj45(3)  

tempStatusChange 1.3.6.1.4.1.2745.1.0.11
This trap will be sent when the temperature falls outside of the exceptable range. The values of chassisEntityIndex, chassisCurrentTemp and chassisMaxTemp will be included in this traps varBind list.
Status: current Access: read-only
NOTIFICATION-TYPE    

backPlaneFailure 1.3.6.1.4.1.2745.1.0.12
This trap will be sent when there is a backplane failure. The value of modFirstSlot will be included in this traps varBind list.
Status: current Access: read-only
NOTIFICATION-TYPE    

powerSupply5vChange 1.3.6.1.4.1.2745.1.0.13
This trap will be sent when the voltage from the 5 volt power supply falls outside of the exceptable range. The values of powerSupplyEntityIndex, powerSupply5vCurrent, powerSupplyMin, powerSupply5vMax and powerSupplyUnitIdentifier will be included in this traps varBind list.
Status: current Access: read-only
NOTIFICATION-TYPE    

powerSupplyStatusChange 1.3.6.1.4.1.2745.1.0.14
This trap will be sent when a power supply is either turned on or off. The values of powerSupplyEntityIndex, powerSupplyStatus and powerSupplyUnitIdentifier will be included in this traps varBind list.
Status: current Access: read-only
NOTIFICATION-TYPE    

powerSupplyInsertion 1.3.6.1.4.1.2745.1.0.15
This trap will be sent when a power supply is inserted. The values of powerSupplyEntityIndex, powerSupplyType and powerSupplyUnitIdentifier will be included in this traps varBind list.
Status: current Access: read-only
NOTIFICATION-TYPE    

powerSupplyRemoval 1.3.6.1.4.1.2745.1.0.16
This trap will be sent when a power supply is removed. The values of powerSupplyEntityIndex, powerSupplyType and powerSupplyUnitIdentifier will be included in this traps varBind list.
Status: current Access: read-only
NOTIFICATION-TYPE    

chassisEntityReset 1.3.6.1.4.1.2745.1.0.17
This trap is sent when a chassis is reset. The values of lastEntityResetIndex, lastEntityResetReason, and lastEntityResetTime will be included in this traps varBind list.
Status: current Access: read-only
NOTIFICATION-TYPE    

moduleEntityReset 1.3.6.1.4.1.2745.1.0.18
This trap is sent when a module is reset. The values of lastEntityResetIndex, lastEntityResetReason, and lastEntityResetTime, modType, modFirstSlot and modNumSlotsOccupied will be included in this traps varBind list.
Status: current Access: read-only
NOTIFICATION-TYPE    

eportEntityReset 1.3.6.1.4.1.2745.1.0.19
This trap is sent when a port is reset. The values of lastEntityResetIndex, lastEntityResetReason, and lastEntityResetTime, modType, modFirstSlot, modNumSlotsOccupied, and ePortParentRelPos will be included in this traps varBind list.
Status: current Access: read-only
NOTIFICATION-TYPE    

moduleInsertion 1.3.6.1.4.1.2745.1.0.20
This trap is sent when a module is inserted to a slot. The values of modEntityIndex, modFirstSlot, modType, modNumSlotsOccupied will be included in this traps varBind list.
Status: current Access: read-only
NOTIFICATION-TYPE    

moduleRemoval 1.3.6.1.4.1.2745.1.0.21
This trap is sent when a module is removed from a slot. The values of modEntityIndex, modFirstSlot, modType, modNumSlotsOccupied will be included in this traps varBind list.
Status: current Access: read-only
NOTIFICATION-TYPE    

unknownModule 1.3.6.1.4.1.2745.1.0.22
This trap is sent when a module is inserted and it's type cannot be determined. The values of modEntityIndex, modType, modFirstSlot, modNumSlotsOccupied will be included in this traps varBind list.
Status: current Access: read-only
NOTIFICATION-TYPE    

moduleFailure 1.3.6.1.4.1.2745.1.0.23
This trap is sent when a module fails and thus is inaccessible. The value of modFirtSlot will be included in this traps varBind list.
Status: current Access: read-only
NOTIFICATION-TYPE    

ePortLinkStatusChange 1.3.6.1.4.1.2745.1.0.24
This trap is sent when there is a change in the link state of a port. The values of ePortLinkStatus, ePortIndex, modType, modFirstSlot, and modNumSlotsOccupied will be included in this traps varBind list.
Status: current Access: read-only
NOTIFICATION-TYPE    

ePortAdminChange 1.3.6.1.4.1.2745.1.0.25
This trap is sent when a user changes the admin state of a port from enable to disable or vice versa. The values of ePortAdminState ePortEntityIndex, modType, modFirstSlot, modNumSlotsOccupied, will be included in this traps varBind list.
Status: current Access: read-only
NOTIFICATION-TYPE    

rtwSwitchOverChange 1.3.6.1.4.1.2745.1.0.26
This trap is sent when a switchover from the primary to the secondary port and vice versa has occured. The values of rtwEntityIndex, rtwActivePort, modFirstSlot, modNumSlotsOccupied will be included in this traps varBind list.
Status: current Access: read-only
NOTIFICATION-TYPE