LBHUB-RBLC-MIB

File: LBHUB-RBLC-MIB.mib (47403 bytes)

Imported modules

RFC1155-SMI SNMPv2-TC

Imported symbols

enterprises OBJECT-TYPE DisplayString
TimeTicks IpAddress Counter
Gauge mib-2 mgmt
DisplayString

Defined Types

AccessGroupEntry  
SEQUENCE    
  accessGroupAddr OCTET STRING Size(6)
  accessGroupInUse INTEGER
  accessGroupNon INTEGER
  accessGroupFree INTEGER
  accessGroupMgmt INTEGER
  accessGroupN1 INTEGER
  accessGroupN2 INTEGER
  accessGroupN3 INTEGER
  accessGroupN4 INTEGER
  accessGroupN5 INTEGER
  accessGroupN6 INTEGER
  accessGroupN7 INTEGER
  accessGroupN8 INTEGER
  accessGroupN9 INTEGER
  accessGroupN10 INTEGER
  accessGroupN11 INTEGER
  accessGroupN12 INTEGER
  accessGroupN13 INTEGER
  accessGroupN14 INTEGER
  accessGroupN15 INTEGER
  accessGroupN16 INTEGER
  accessGroupMembers INTEGER

AccessGroupNamedIdEntry  
SEQUENCE    
  accessGroupNamedIdIndex INTEGER
  accessGroupNamedIdIdentifier OCTET STRING Size(20)

PcolEntry  
SEQUENCE    
  pcolIndex INTEGER
  pcolInUse INTEGER
  pcolState INTEGER
  pcolIdentifier OCTET STRING Size(16)
  pcolOffset INTEGER
  pcolMask OCTET STRING Size(8)
  pcolMatch OCTET STRING Size(8)
  pcolDecision INTEGER
  pcolAction INTEGER

BrgMgmtEntry  
SEQUENCE    
  brgMgmtAddr IpAddress
  brgMgmtName OCTET STRING

DynEntry  
SEQUENCE    
  dynAddr OCTET STRING Size(6)
  dynHomePort INTEGER
  dynInUse INTEGER

TypeFltrEntry  
SEQUENCE    
  typeFltrFrom INTEGER
  typeFltrTo INTEGER
  typeFltrInUse INTEGER

SupportedEntry  
SEQUENCE    
  supportedIndex INTEGER
  supportedID OBJECT IDENTIFIER

UnSupportedEntry  
SEQUENCE    
  unSupportedIndex INTEGER
  unSupportedID OBJECT IDENTIFIER

TrapCountEntry  
SEQUENCE    
  trapCountIndex INTEGER
  trapCountType INTEGER
  trapCountCode INTEGER
  trapCountEnable INTEGER
  trapCountCount Counter
  trapCountTime TimeTicks
  trapCountDescr DisplayString

TrapDestsEntry  
SEQUENCE    
  trapDestsIpAddr IpAddress
  trapDestsSerialAddr IpAddress
  trapDestsPhoneNumber OCTET STRING
  trapDestsSendTo INTEGER
  trapDestsEnable INTEGER
  trapDestsCommunityName OCTET STRING
  trapDestsInUse INTEGER

SipNxtBootEntry  
SEQUENCE    
  sipNxtBootCurIp IpAddress
  sipNxtBootNxtIp IpAddress
  sipNxtBootBbdCast INTEGER
  sipNxtBootSubnetMask IpAddress

Defined Values

mib-2 1.3.6.1.2.1
OBJECT IDENTIFIER    

system 1.3.6.1.2.1.1
OBJECT IDENTIFIER    

interfaces 1.3.6.1.2.1.2
OBJECT IDENTIFIER    

at 1.3.6.1.2.1.3
OBJECT IDENTIFIER    

ip 1.3.6.1.2.1.4
OBJECT IDENTIFIER    

icmp 1.3.6.1.2.1.5
OBJECT IDENTIFIER    

tcp 1.3.6.1.2.1.6
OBJECT IDENTIFIER    

udp 1.3.6.1.2.1.7
OBJECT IDENTIFIER    

bicctech 1.3.6.1.4.1.170
OBJECT IDENTIFIER    

bdn 1.3.6.1.4.1.170.1
OBJECT IDENTIFIER    

bdnII 1.3.6.1.4.1.170.1.1
OBJECT IDENTIFIER    

spiderII 1.3.6.1.4.1.170.1.1.3
OBJECT IDENTIFIER    

spProduct 1.3.6.1.4.1.170.1.1.3.1
OBJECT IDENTIFIER    

spIndex 1.3.6.1.4.1.170.1.1.3.2
OBJECT IDENTIFIER    

spGeneral 1.3.6.1.4.1.170.1.1.3.3
OBJECT IDENTIFIER    

spSnmp 1.3.6.1.4.1.170.1.1.3.4
OBJECT IDENTIFIER    

spProtocols 1.3.6.1.4.1.170.1.1.3.6
OBJECT IDENTIFIER    

bridge 1.3.6.1.4.1.170.1.1.3.1.1
OBJECT IDENTIFIER    

bridgeID 1.3.6.1.4.1.170.1.1.3.1.1.1
OBJECT IDENTIFIER    

bridgeData 1.3.6.1.4.1.170.1.1.3.1.1.2
OBJECT IDENTIFIER    

r285 1.3.6.1.4.1.170.1.1.3.1.1.1.3
OBJECT IDENTIFIER    

r285FilterDbase 1.3.6.1.4.1.170.1.1.3.1.1.1.3.1
OBJECT IDENTIFIER    

broadcastFltr 1.3.6.1.4.1.170.1.1.3.1.1.1.3.1.1
The state of broadcast filtering. If this object is set to ON then the bridge will not forward frames with the ethernet broadcast address. The bridge itself will still be able to receive frames with the ethernet broadcast address, e.g. ARP requests.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

accessGroupChecking 1.3.6.1.4.1.170.1.1.3.1.1.1.3.1.2
The state of Access Group Checking. If this object is ON, then each frame is subject to Access Group Checking.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

accessGroupLearning 1.3.6.1.4.1.170.1.1.3.1.1.1.3.1.3
This object determines whether learned addresses belong to the Non Access Group or the Free Access Group. It is only valid when accessGroupChecking is set to ON.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER non(1), free(2)  

accessGroupDbase 1.3.6.1.4.1.170.1.1.3.1.1.1.3.1.4
OBJECT IDENTIFIER    

pcolFltr 1.3.6.1.4.1.170.1.1.3.1.1.1.3.1.6
OBJECT IDENTIFIER    

accessGroupTableMaxEntries 1.3.6.1.4.1.170.1.1.3.1.1.1.3.1.4.1
The maximum number of entries in the table accessGroupTable. In the RBLC this value is 2500.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

accessGroupTableCurEntries 1.3.6.1.4.1.170.1.1.3.1.1.1.3.1.4.2
The current number of entries in the table accessGroupTable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

accessGroupTable 1.3.6.1.4.1.170.1.1.3.1.1.1.3.1.4.3
A list of Access Group Entries. The number is given by accessGroupTableCurEntries.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AccessGroupEntry

accessGroupEntry 1.3.6.1.4.1.170.1.1.3.1.1.1.3.1.4.3.1
An Access Group Entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  AccessGroupEntry  

accessGroupAddr 1.3.6.1.4.1.170.1.1.3.1.1.1.3.1.4.3.1.1
The MAC address of this entry.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

accessGroupInUse 1.3.6.1.4.1.170.1.1.3.1.1.1.3.1.4.3.1.2
This object is ON for valid entries. The entry may be removed by setting this object to OFF.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notInUse(1), inUse(2)  

accessGroupNon 1.3.6.1.4.1.170.1.1.3.1.1.1.3.1.4.3.1.3
Dictates if this MAC address shall belong to the Non-Access group.Membership of this group is mutually exclusive from all other groups.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER inGroup(1), notInGroup(2)  

accessGroupFree 1.3.6.1.4.1.170.1.1.3.1.1.1.3.1.4.3.1.4
Dictates if this MAC address shall belong to the Free Access Group.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER inGroup(1), notInGroup(2)  

accessGroupMgmt 1.3.6.1.4.1.170.1.1.3.1.1.1.3.1.4.3.1.5
Dictates if this MAC address shall belong to the Management group.Membership of this group is mutually exclusive from all other groups.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER inGroup(1), notInGroup(2)  

accessGroupN1 1.3.6.1.4.1.170.1.1.3.1.1.1.3.1.4.3.1.6
Dictates if this MAC address shall belong to Named Access Group 1.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER inGroup(1), notInGroup(2)  

accessGroupN2 1.3.6.1.4.1.170.1.1.3.1.1.1.3.1.4.3.1.7
Dictates if this MAC address shall belong to Named Access Group 2.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER inGroup(1), notInGroup(2)  

accessGroupN3 1.3.6.1.4.1.170.1.1.3.1.1.1.3.1.4.3.1.8
Dictates if this MAC address shall belong to Named Access Group 3.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER inGroup(1), notInGroup(2)  

accessGroupN4 1.3.6.1.4.1.170.1.1.3.1.1.1.3.1.4.3.1.9
Dictates if this MAC address shall belong to Named Access Group 4.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER inGroup(1), notInGroup(2)  

accessGroupN5 1.3.6.1.4.1.170.1.1.3.1.1.1.3.1.4.3.1.10
Dictates if this MAC address shall belong to Named Access Group 5.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER inGroup(1), notInGroup(2)  

accessGroupN6 1.3.6.1.4.1.170.1.1.3.1.1.1.3.1.4.3.1.11
Dictates if this MAC address shall belong to Named Access Group 6.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER inGroup(1), notInGroup(2)  

accessGroupN7 1.3.6.1.4.1.170.1.1.3.1.1.1.3.1.4.3.1.12
Dictates if this MAC address shall belong to Named Access Group 7.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER inGroup(1), notInGroup(2)  

accessGroupN8 1.3.6.1.4.1.170.1.1.3.1.1.1.3.1.4.3.1.13
Dictates if this MAC address shall belong to Named Access Group 8.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER inGroup(1), notInGroup(2)  

accessGroupN9 1.3.6.1.4.1.170.1.1.3.1.1.1.3.1.4.3.1.14
Dictates if this MAC address shall belong to Named Access Group 9.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER inGroup(1), notInGroup(2)  

accessGroupN10 1.3.6.1.4.1.170.1.1.3.1.1.1.3.1.4.3.1.15
Dictates if this MAC address shall belong to Named Access Group 10.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER inGroup(1), notInGroup(2)  

accessGroupN11 1.3.6.1.4.1.170.1.1.3.1.1.1.3.1.4.3.1.16
Dictates if this MAC address shall belong to Named Access Group 11.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER inGroup(1), notInGroup(2)  

accessGroupN12 1.3.6.1.4.1.170.1.1.3.1.1.1.3.1.4.3.1.17
Dictates if this MAC address shall belong to Named Access Group 12.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER inGroup(1), notInGroup(2)  

accessGroupN13 1.3.6.1.4.1.170.1.1.3.1.1.1.3.1.4.3.1.18
Dictates if this MAC address shall belong to Named Access Group 13.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER inGroup(1), notInGroup(2)  

accessGroupN14 1.3.6.1.4.1.170.1.1.3.1.1.1.3.1.4.3.1.19
Dictates if this MAC address shall belong to Named Access Group 14.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER inGroup(1), notInGroup(2)  

accessGroupN15 1.3.6.1.4.1.170.1.1.3.1.1.1.3.1.4.3.1.20
Dictates if this MAC address shall belong to Named Access Group 15.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER inGroup(1), notInGroup(2)  

accessGroupN16 1.3.6.1.4.1.170.1.1.3.1.1.1.3.1.4.3.1.21
Dictates if this MAC address shall belong to Named Access Group 16.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER inGroup(1), notInGroup(2)  

accessGroupMembers 1.3.6.1.4.1.170.1.1.3.1.1.1.3.1.4.3.1.22
This is a bitmap, giving membership of the sixteen named access groups in a single integer. Bit 0 corresponds to group N1, and bit 15 to group N16. Management stations which can make use of integer bitmaps should obviously use this variable, as it is more compact in PDU bandwidth, and is considerably faster for the agent to generate.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

accessGroupNamedIdMaxEntries 1.3.6.1.4.1.170.1.1.3.1.1.1.3.1.4.4
The number Named Access Groups. In the RBLC this object has the value 16.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

accessGroupNamedIdTable 1.3.6.1.4.1.170.1.1.3.1.1.1.3.1.4.5
A list of Named Access Group identifiers. The number is given by accessGroupNamedIdMaxEntries.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AccessGroupNamedIdEntry

accessGroupNamedIdEntry 1.3.6.1.4.1.170.1.1.3.1.1.1.3.1.4.5.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  AccessGroupNamedIdEntry  

accessGroupNamedIdIndex 1.3.6.1.4.1.170.1.1.3.1.1.1.3.1.4.5.1.1
A unique value for each Named Access Group. Its value ranges between 1 and the value of accessGroupNamedNumber.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

accessGroupNamedIdIdentifier 1.3.6.1.4.1.170.1.1.3.1.1.1.3.1.4.5.1.2
A textual identifier for this Named Access Group.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

pcolOperation 1.3.6.1.4.1.170.1.1.3.1.1.1.3.1.6.1
The logical operation of the individual protocol filters.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER and(1), or(2)  

pcolNumber 1.3.6.1.4.1.170.1.1.3.1.1.1.3.1.6.2
The number of individual protocol filters. For the RBLC this value will be 8.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

pcolTable 1.3.6.1.4.1.170.1.1.3.1.1.1.3.1.6.3
A list of protocol filter entries. The number is given by pcolNumber. This size is fixed. No gaps are allowed in the table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PcolEntry

pcolEntry 1.3.6.1.4.1.170.1.1.3.1.1.1.3.1.6.3.1
A protocol filter entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PcolEntry  

pcolIndex 1.3.6.1.4.1.170.1.1.3.1.1.1.3.1.6.3.1.1
A unique value for each protocol filter. Its value ranges between 1 and the value of pcolNumber.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

pcolInUse 1.3.6.1.4.1.170.1.1.3.1.1.1.3.1.6.3.1.2
This object controls the appearance of valid protocol filter table entries, i.e. entries which contain a meaningful filter. Setting this field to 'notinuse' causes the row to be deleted
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notinuse(1), inuse(2)  

pcolState 1.3.6.1.4.1.170.1.1.3.1.1.1.3.1.6.3.1.3
This object is ON if the protocol filter in this entry is being used to filter frames. This object is only meaningful if pcolInUse is set to 'inuse'. This protocol filter is turned off by setting this object to OFF.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

pcolIdentifier 1.3.6.1.4.1.170.1.1.3.1.1.1.3.1.6.3.1.4
A string used to identify this protocol filter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

pcolOffset 1.3.6.1.4.1.170.1.1.3.1.1.1.3.1.6.3.1.5
Offset within the frame of the 4-byte field on which filtering is to be performed.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

pcolMask 1.3.6.1.4.1.170.1.1.3.1.1.1.3.1.6.3.1.6
This object is ANDed with the 4-byte field in the frame. The result is compared with pcolMatch.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

pcolMatch 1.3.6.1.4.1.170.1.1.3.1.1.1.3.1.6.3.1.7
This object is compared with the result of ANDing pcolMask with the 4-byte field.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

pcolDecision 1.3.6.1.4.1.170.1.1.3.1.1.1.3.1.6.3.1.8
Determines whether the comparison of pcolMatch and the masked data field will cause the action specified in pcolAction to be taken on a match, or not.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER nomatch(1), match(2)  

pcolAction 1.3.6.1.4.1.170.1.1.3.1.1.1.3.1.6.3.1.9
The action specified for this individual protocol filter.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER filter(1), lopriority(2), hipriority(3)  

bridgeMgmt 1.3.6.1.4.1.170.1.1.3.1.1.2.1
OBJECT IDENTIFIER    

filterDataBase 1.3.6.1.4.1.170.1.1.3.1.1.2.2
OBJECT IDENTIFIER    

bridgeRestart 1.3.6.1.4.1.170.1.1.3.1.1.2.3
OBJECT IDENTIFIER    

brgMgmtMyName 1.3.6.1.4.1.170.1.1.3.1.1.2.1.1
The name associated with this bridge for the purpose of remote management. It is this name which shall be used within multicast name PDU's
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

brgMgmtHelloTime 1.3.6.1.4.1.170.1.1.3.1.1.2.1.2
The time interval, in seconds, between the transmission of successive bridge management hello packets
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

brgMgmtManagerAddr 1.3.6.1.4.1.170.1.1.3.1.1.2.1.3
The IP Address of the remote station currently managing the bridge. This remote station can be another bridge, or any device supporting Telnet. Note, that this address is not the same as that of a possible SNMP client which is managing the bridge.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

brgMgmtTableMaxEntries 1.3.6.1.4.1.170.1.1.3.1.1.2.1.4
The maximum size of the Bridge Name Table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

brgMgmtTableCurEntries 1.3.6.1.4.1.170.1.1.3.1.1.2.1.5
The current number of known remote bridges in the Bridge Name Table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

brgMgmtTable 1.3.6.1.4.1.170.1.1.3.1.1.2.1.6
The table of known remote bridges which can be managed by this bridge.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    BrgMgmtEntry

brgMgmtEntry 1.3.6.1.4.1.170.1.1.3.1.1.2.1.6.1
An entry in the Remote Bridge Table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  BrgMgmtEntry  

brgMgmtAddr 1.3.6.1.4.1.170.1.1.3.1.1.2.1.6.1.1
The IP address of a remote bridge
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

brgMgmtName 1.3.6.1.4.1.170.1.1.3.1.1.2.1.6.1.2
The name of the bridge to use when trying to remotely administer it.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

dynDBase 1.3.6.1.4.1.170.1.1.3.1.1.2.2.1
OBJECT IDENTIFIER    

dynType 1.3.6.1.4.1.170.1.1.3.1.1.2.2.1.1
This object specifies how the dynamic filtering is implemented.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hardware(1), software(2)  

dynTableMaxEntries 1.3.6.1.4.1.170.1.1.3.1.1.2.2.1.2
The maximum number of entries in the dynamic filter table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

dynTableCurEntries 1.3.6.1.4.1.170.1.1.3.1.1.2.2.1.3
The current number of entries in the dynamic filter table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

dynTable 1.3.6.1.4.1.170.1.1.3.1.1.2.2.1.4
The dynamic filter table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DynEntry

dynEntry 1.3.6.1.4.1.170.1.1.3.1.1.2.2.1.4.1
A dynamic table entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  DynEntry  

dynAddr 1.3.6.1.4.1.170.1.1.3.1.1.2.2.1.4.1.1
The dynamically learned MAC source address.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

dynHomePort 1.3.6.1.4.1.170.1.1.3.1.1.2.2.1.4.1.2
The port number, sptreePortIndex, on which the dynamic source address was received.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

dynInUse 1.3.6.1.4.1.170.1.1.3.1.1.2.2.1.4.1.3
This object is INUSE for valid dynamic table entries. Entries may be removed by setting it to NOTINUSE.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notinuse(1), inuse(2)  

typeFltr 1.3.6.1.4.1.170.1.1.3.1.1.2.2.5
OBJECT IDENTIFIER    

typeFltrStt 1.3.6.1.4.1.170.1.1.3.1.1.2.2.5.1
State of type filtering.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), only(2), except(3)  

typeFltrMaxEntries 1.3.6.1.4.1.170.1.1.3.1.1.2.2.5.2
The maximum number of entries allowed in the static type filter table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

typeFltrCurEntries 1.3.6.1.4.1.170.1.1.3.1.1.2.2.5.3
The current number of entries in the static type filter table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

typeFltrTable 1.3.6.1.4.1.170.1.1.3.1.1.2.2.5.4
Static type filter table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TypeFltrEntry

typeFltrEntry 1.3.6.1.4.1.170.1.1.3.1.1.2.2.5.4.1
An entry in the static type filter table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  TypeFltrEntry  

typeFltrFrom 1.3.6.1.4.1.170.1.1.3.1.1.2.2.5.4.1.1
Type filter table 'from' type (inclusive).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

typeFltrTo 1.3.6.1.4.1.170.1.1.3.1.1.2.2.5.4.1.2
Type filter table 'to' type (inclusive).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

typeFltrInUse 1.3.6.1.4.1.170.1.1.3.1.1.2.2.5.4.1.3
Entries are removed by setting this object to NOTINUSE.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notinuse(1), inuse(2)  

bridgeBootCount 1.3.6.1.4.1.170.1.1.3.1.1.2.3.1
The number of times this system has been auto-booted. (This refers to auto-reboots only.)
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

bridgeRestartCause1 1.3.6.1.4.1.170.1.1.3.1.1.2.3.2
A code for a system error that causes a self-initiated restart. These codes are ordered from the earliest to the latest ie bridgeRestartCause1 is the earliest, and bridgeRestartCause4 is the latest. The code is expressed as an 8 digit hex number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

bridgeRestartCause2 1.3.6.1.4.1.170.1.1.3.1.1.2.3.3
A code for a system error that causes a self-initiated restart. These codes are ordered from the earliest to the latest ie bridgeRestartCause1 is the earliest, and bridgeRestartCause4 is the latest. The code is expressed as an 8 digit hex number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

bridgeRestartCause3 1.3.6.1.4.1.170.1.1.3.1.1.2.3.4
A code for a system error that causes a self-initiated restart. These codes are ordered from the earliest to the latest ie bridgeRestartCause1 is the earliest, and bridgeRestartCause4 is the latest. The code is expressed as a 8 digit hex number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

bridgeRestartCause4 1.3.6.1.4.1.170.1.1.3.1.1.2.3.5
A code for a system error that causes a self-initiated restart. These codes are ordered from the earliest to the latest ie bridgeRestartCause1 is the earliest, and bridgeRestartCause4 is the latest. The code is expressed as a 8 digit hex number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

supportedMaxEntries 1.3.6.1.4.1.170.1.1.3.2.1
Number of entries in the supported table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

supportedTable 1.3.6.1.4.1.170.1.1.3.2.2
A table of OBJECT IDENTIFIERs, pointing to MIB groups which are supported in this agent.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SupportedEntry

supportedEntry 1.3.6.1.4.1.170.1.1.3.2.2.1
The OBJECT IDENTIFIER for a portion of the MIB, showing which parts of the MIB are implemented by the product.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SupportedEntry  

supportedIndex 1.3.6.1.4.1.170.1.1.3.2.2.1.1
A simple numeric index into the supported table, to assist with indexing.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

supportedID 1.3.6.1.4.1.170.1.1.3.2.2.1.2
A pointer to a supported MIB sub-tree
Status: mandatory Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

unSupportedMaxEntries 1.3.6.1.4.1.170.1.1.3.2.3
Number of entries in the unsupported table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

unSupportedTable 1.3.6.1.4.1.170.1.1.3.2.4
A table of OBJECT IDENTIFIERs, pointing to MIB groups, tables OR variables which are NOT supported in this agent. The unsupported OBJECT IDENTIFIERs are always subtrees of the supported table (that is, they show the management station what elements of the supported groups are not implemented).
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    UnSupportedEntry

unSupportedEntry 1.3.6.1.4.1.170.1.1.3.2.4.1
The OBJECT IDENTIFIER for a portion of the MIB, showing which parts of the supported MIB are not implemented by the product.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  UnSupportedEntry  

unSupportedIndex 1.3.6.1.4.1.170.1.1.3.2.4.1.1
A simple numeric index into the unsupported table, to assist with indexing.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

unSupportedID 1.3.6.1.4.1.170.1.1.3.2.4.1.2
A pointer to an unsupported sub-tree of a supported MIB sub-tree
Status: mandatory Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

mibVersion 1.3.6.1.4.1.170.1.1.3.3.1
This is an object which is unique to a particular MIB in a particular product. It is read by the SpiderManager and is broken down into the following structure: ':', where 'product version' is a string of the type '2.3.1' (product-specific), and 'MIB version' identifies the particular flavour of SpiderMIB, such as '1:0'
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

admin 1.3.6.1.4.1.170.1.1.3.3.2
OBJECT IDENTIFIER    

admSessionStt 1.3.6.1.4.1.170.1.1.3.3.2.1
The state of the management session on the product. Management sessions can only be invoked if the value of this object is noManagementSession(1). Traps may be generated when this object changes (implementation specific).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noManagementSession(1), localManagementSession(2), telnetManagementSession(3), snmpManagementSession(4), remoteBridgeManagementSession(5), latManagementSession(6), tp4ManagementSession(7), vtpManagementSession(8)  

admManagerAddr 1.3.6.1.4.1.170.1.1.3.3.2.2
The IP address of the product initiating an SNMP or Telnet management session. This object is 0.0.0.0 when no management session is underway, and is set to this value automatically when a session closes, or is timed out.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

admLockDevice 1.3.6.1.4.1.170.1.1.3.3.2.3
The host sets this variable to prevent other hosts from being able to use SNMP SET requests. This is intended for use when a host needs to carry out a series of SET operations as effectively one atomic access. When this variable is set, the IP address of the host is copied into 'admManagerAddr', and the management session timer is started. If the session timer expires without any contact by the locking host, the session lock is cleared, and the IP address zeroed. The standard Spider session time limit is two minutes.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

admOverrideDevice 1.3.6.1.4.1.170.1.1.3.3.2.4
The host sets this variable to override the current lock owner. This has the effect of zeroing the 'admLockDevice' and 'admManagerAddr' variables, and cancelling the management session. A 'sessionAborted' trap is sent to the host which locked the previous management session.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

admPrompt 1.3.6.1.4.1.170.1.1.3.3.2.5
The string used for the command line prompt in a local or remote administration session.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

admPassword 1.3.6.1.4.1.170.1.1.3.3.2.6
The password required to start a management session to the administration mode of the product. It is intended that this be encrypted by a simple algorithm before it is sent onto the network.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

admSignOnMsg 1.3.6.1.4.1.170.1.1.3.3.2.7
The sign on message presented at the start of a local or remote administration session. This is typically the product type, name and version.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

admMgmtSessionTime 1.3.6.1.4.1.170.1.1.3.3.2.8
The timeout used for management session closure. If a management session is idle for this time it will close automatically and no configuration change will be made. The unit is seconds.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

admLastWriteAddr 1.3.6.1.4.1.170.1.1.3.3.2.9
The IP address of the source of the last received SNMP SET request.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

admRemManagerAddr 1.3.6.1.4.1.170.1.1.3.3.2.10
The address of the product initiating a management session corresponding to admSessionStt. This object is of zero length when no management session is underway, and is set to this value automatically when a session closes, or is timed out.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..64)  

resources 1.3.6.1.4.1.170.1.1.3.3.4
OBJECT IDENTIFIER    

resSmartGatewayAddr 1.3.6.1.4.1.170.1.1.3.3.4.3
The IP address of the default gateway for the product. A value of 0.0.0.0 is used if there is no default gateway.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

restart 1.3.6.1.4.1.170.1.1.3.3.5
OBJECT IDENTIFIER    

rstDoBoot 1.3.6.1.4.1.170.1.1.3.3.5.1
When set to doBoot(1) the product should send the getResponse message using the parameters rstBootFrom and rstBootfilename(if applicable), and then reboot. Reading this object always returns a value of noMeaning(2).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER doBoot(1), noMeaning(2)  

rstDoRestart 1.3.6.1.4.1.170.1.1.3.3.5.4
When set to doRestart(1) the product should restart after sending the getResponse message. Reading this object always returns a value of noMeaning(2).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER doRestart(1), noMeaning(2)  

rstNeedRestart 1.3.6.1.4.1.170.1.1.3.3.5.5
If the value of this object is needRestart(2) some configuration parameters have been changed which will not take effect until the product is restarted using rstDoRestart.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER dontNeedRestart(1), needRestart(2)  

rstDownLoadStt 1.3.6.1.4.1.170.1.1.3.3.5.6
If the value of this object is downLoading(2) a configuration download is in progress. The following rules apply: If a management session closes normally and rstDownLoadStt has the value downLoading(2) non-volatile storage is updated and the product restarts. If a management session closes for any other reason and rstDownLoadStt has the value downLoading(2) non-volatile storage is NOT updated and the product restarts. This ensures the original configuration is restored leaving the product in a consistent state.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notDownLoading(1), downLoading(2)  

rstNumberRestarts 1.3.6.1.4.1.170.1.1.3.3.5.7
A count of the number of restarts (this includes reboots) the product has undergone.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

rstLastConfigChngTime 1.3.6.1.4.1.170.1.1.3.3.5.8
The time at which the configuration of the agent was last changed. A configuration change is considered to have been made when non-volatile memory is updated and the value of this object is the value of sysUpTime when this occurs. Note that a configuration change can be made using any access method such as SNMP, a local terminal or a TELNET connection.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

trapCount 1.3.6.1.4.1.170.1.1.3.4.1
OBJECT IDENTIFIER    

trapCountClear 1.3.6.1.4.1.170.1.1.3.4.1.1
When set to clearCounts(1) the count of all traps in the trapCountTable is reset to zero. Reading this object always returns a value of noMeaning(2).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER clearCounts(1), noMeaning(2)  

trapCountMaxEntries 1.3.6.1.4.1.170.1.1.3.4.1.2
The maximum number of entries allowed in the trapCountTable. The actual number is the total of all of the types of generic and enterprise traps that the device can send.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

trapCountTable 1.3.6.1.4.1.170.1.1.3.4.1.3
A list of the numbers of traps of each type sent.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TrapCountEntry

trapCountEntry 1.3.6.1.4.1.170.1.1.3.4.1.3.1
An entry of trap counts for a particular trap type.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  TrapCountEntry  

trapCountIndex 1.3.6.1.4.1.170.1.1.3.4.1.3.1.1
A numeric index used to index the trapCountTable. Its value ranges between 1 and the value of trapCountMaxEntries.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

trapCountType 1.3.6.1.4.1.170.1.1.3.4.1.3.1.2
The type of trap, generic or enterprise.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER generic(1), enterprise(2)  

trapCountCode 1.3.6.1.4.1.170.1.1.3.4.1.3.1.3
The enumerated code for the trap, generic as specified in [3] or enterprise as specified in the management information document associated with the product.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

trapCountEnable 1.3.6.1.4.1.170.1.1.3.4.1.3.1.4
When the value is enableTrap(1) traps of this type are forwarded to all stations in the trapDestsTable, counted in the trapCountTable and stored in the allTrapTable(if this is supported by the product). When the value is disableTrap(2) traps of this type are not forwarded to all stations in the trapDestsTable. They are however counted in the trapCountTable and entered in the allTrapTable (if this is supported by the product).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER enableTrap(1), disableTrap(2)  

trapCountCount 1.3.6.1.4.1.170.1.1.3.4.1.3.1.5
A count of the number of traps sent of each type since the last reset of the product.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

trapCountTime 1.3.6.1.4.1.170.1.1.3.4.1.3.1.6
The time of the last occurrence of a particular trap type since the last reset of the product in one hundredths of a second.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

trapCountDescr 1.3.6.1.4.1.170.1.1.3.4.1.3.1.7
A description of the type of enterprise trap being transmitted.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

trapDests 1.3.6.1.4.1.170.1.1.3.4.3
OBJECT IDENTIFIER    

trapDestsCheckAddr 1.3.6.1.4.1.170.1.1.3.4.3.1
The trapDestsCheckAddr object selects whether the IP address of a station requesting a management session is validated for presence in the trapDests table. If validation is enabled and the address in the SNMP request is not present in the trapDests table the request is rejected. A trap may be sent if this occurs, the choice is product specific.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER validateAddresses(1), dontValidateAddresses(2)  

trapDestsMaxEntries 1.3.6.1.4.1.170.1.1.3.4.3.2
The maximum number of entries in the trapDestsTable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

trapDestsCurEntries 1.3.6.1.4.1.170.1.1.3.4.3.3
The number of traps in the trapDestsTable at any instant.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

trapDestsTable 1.3.6.1.4.1.170.1.1.3.4.3.4
A list of the destinations to which traps are sent.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TrapDestsEntry

trapDestsEntry 1.3.6.1.4.1.170.1.1.3.4.3.4.1
An entry for a station address to which traps are sent
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  TrapDestsEntry  

trapDestsIpAddr 1.3.6.1.4.1.170.1.1.3.4.3.4.1.1
The IP address of a station to which traps are sent.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

trapDestsSerialAddr 1.3.6.1.4.1.170.1.1.3.4.3.4.1.2
The serial IP address of a station to which traps are sent.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

trapDestsPhoneNumber 1.3.6.1.4.1.170.1.1.3.4.3.4.1.3
The telephone number of a modem connected to the product which can be dialed up to send traps.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

trapDestsSendTo 1.3.6.1.4.1.170.1.1.3.4.3.4.1.4
The interface to send traps to. This selects whether to send traps via the primary medium or the serial line.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER primaryMedium(1), serialLine(2)  

trapDestsEnable 1.3.6.1.4.1.170.1.1.3.4.3.4.1.5
When the value is sendTraps(1) traps are sent to this address and are counted in the trapCountTable and entered in the allTrapTable. When the value is dontSendTraps(2) traps are not sent to this address. They are however counted in the trapCountTable and are entered in the allTrapTable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER sendTraps(1), dontSendTraps(2)  

trapDestsCommunityName 1.3.6.1.4.1.170.1.1.3.4.3.4.1.6
The community name to use when sending traps to this address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

trapDestsInUse 1.3.6.1.4.1.170.1.1.3.4.3.4.1.7
Whether this entry is in use or not. This field is used to delete entries from this table.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notInUse(1), inUse(2)  

spantree 1.3.6.1.4.1.170.1.1.3.6.14
OBJECT IDENTIFIER    

sptreeGroupAddr 1.3.6.1.4.1.170.1.1.3.6.14.15
The multicast address used by BPDUs.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

sptreeStt 1.3.6.1.4.1.170.1.1.3.6.14.16
The Spanning Tree State of the bridge.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

sptreeInit 1.3.6.1.4.1.170.1.1.3.6.14.17
When set to INITIALISE the parameters and timers of the Spanning Tree algorithm and protocol are initialised.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noinitialise(1), initialise(2)  

spIp 1.3.6.1.4.1.170.1.1.3.6.16
OBJECT IDENTIFIER    

sipNxtBootTableMaxEntries 1.3.6.1.4.1.170.1.1.3.6.16.1
The maximum number of entries allowed in the NxtBootTable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

sipNxtBootTable 1.3.6.1.4.1.170.1.1.3.6.16.2
A table of IP interfaces, used to change the IP address, subnet mask and broadcast address, the next time the system is booted. The table indexed by the current IP address of the interface.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SipNxtBootEntry

sipNxtBootEntry 1.3.6.1.4.1.170.1.1.3.6.16.2.1
This table entry consists of the current IP address of this interface, followed by the new IP address, broadcast form and subnet masks. These will not take effect, until the system is rebooted.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SipNxtBootEntry  

sipNxtBootCurIp 1.3.6.1.4.1.170.1.1.3.6.16.2.1.1
This is the current IP address of the interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

sipNxtBootNxtIp 1.3.6.1.4.1.170.1.1.3.6.16.2.1.2
The desired IP address of this interface, once the system is rebooted. The subnetmask will be changed accordingly, to cover the default mask for that IP address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress  

sipNxtBootBbdCast 1.3.6.1.4.1.170.1.1.3.6.16.2.1.3
Sets the broadcast address to be all ones, or all zeroes.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER allones(1), allzeroes(2)  

sipNxtBootSubnetMask 1.3.6.1.4.1.170.1.1.3.6.16.2.1.4
The subnet mask associated with the IP address entry. If sipNxtBootNxtIp is specified, then the subnet mask automatically changes to the default mask for the network class of the new IP entry. If sipNxtBootSubnetMask is also changed, it must at least cover the default for the new IP address (also dependent upon its network class), or the current IP address if no new one specified. Also, if the new address is on a different network, and there are gateways on the current network, a badValue error will be returned.
Status: mandatory Access: read-write
OBJECT-TYPE    
  IpAddress