LANOPTICS-RING-MANAGER-MIB

File: LANOPTICS-RING-MANAGER-MIB.mib (29252 bytes)

Imported modules

RFC-1212 RFC1155-SMI RFC1213-MIB

Imported symbols

OBJECT-TYPE enterprises Counter
IpAddress DisplayString PhysAddress

Defined Types

BITMAP  
INTEGER    

RING-CONFIGURATION  
OCTET STRING    

RmRingEventEntry  
SEQUENCE    
  rmRingEvent OCTET STRING

RmDeviceEntry  
SEQUENCE    
  rmDeviceMacAddress PhysAddress
  rmDeviceUpstream PhysAddress
  rmDeviceAdminState INTEGER
  rmDeviceOperateState INTEGER
  rmDevicePhysLocation INTEGER
  rmDeviceGroupAddress INTEGER
  rmDeviceFunctionAddress INTEGER
  rmDeviceProductID OCTET STRING
  rmDeviceStationID INTEGER
  rmDeviceStationStatus OCTET STRING
  rmDeviceFunctionClass INTEGER
  rmDeviceAccessPriority INTEGER
  rmDeviceMicroLevel OCTET STRING
  rmDeviceMonitored INTEGER
  rmDeviceDaysAllowed INTEGER
  rmDeviceHoursAllowed INTEGER

Defined Values

lanOptics 1.3.6.1.4.1.224
OBJECT IDENTIFIER    

lanOpticsDot5Monitor 1.3.6.1.4.1.224.5
OBJECT IDENTIFIER    

rmServerReportingTo 1.3.6.1.4.1.224.5.1
This gives the IP address for the reporting manager.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

rmRingStatus 1.3.6.1.4.1.224.5.2
This variable indicates the curent ring status.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER beaconing(1), single-station(2), errors-increasing(3), excessive-errors(4)  

rmServerHealthText 1.3.6.1.4.1.224.5.3
This variable describes the status of the ring server in a textural manner.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

rmServerHealth 1.3.6.1.4.1.224.5.4
This variable will describe the status of the ring server.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER initial-State(1), not-Active(2)  

rmRingEventInLog 1.3.6.1.4.1.224.5.5
The number of events currently in the internal event log.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

rmRingEventTable 1.3.6.1.4.1.224.5.6
A table containing the last events. The detailed structure is TBD.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    RmRingEventEntry

rmRingEventEntry 1.3.6.1.4.1.224.5.6.1
An entry containing one event. The index into the table is the event number (32 bits int), where each byte represented by an index digit.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  RmRingEventEntry  

rmRingEvent 1.3.6.1.4.1.224.5.6.1.1
This variable will give the data structure describing a ring event in an internal format
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

rmRingBeaconingStatus 1.3.6.1.4.1.224.5.7
This variable will give the data structure describing the beaconing state of the ring.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

rmRingIsoErrorStatus 1.3.6.1.4.1.224.5.8
This variable will give the data structure describing the isolating error state of the ring.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

rmRingSingleStationStatus 1.3.6.1.4.1.224.5.9
This variable will give the data structure describing the single station state of the ring.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

rmRingFullConfiguration 1.3.6.1.4.1.224.5.10
This variable gives the ring configuration as known to the server. Each MAC address is represented by 6 bytes. The direction is up-stream.
Status: mandatory Access: read-only
OBJECT-TYPE    
  RING-CONFIGURATION  

rmRingConfigurationUpdate 1.3.6.1.4.1.224.5.11
This variable will give a sequence of changes in the ring configuration for the monitored ring.
Status: mandatory Access: read-only
OBJECT-TYPE    
  RING-CONFIGURATION  

rmServerInitProcess 1.3.6.1.4.1.224.5.12
This variable will initialize the server (reset the management module).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

rmServerAdminState 1.3.6.1.4.1.224.5.13
This variable will indicate administrative status of the server. IDLE - 0 The bit # (LSB = 0): REM - bit 0 on CRS - bit 1 on RPS - bit 2 on LBS - bit 3 on
Status: mandatory Access: read-write
OBJECT-TYPE    
  BITMAP  

rmServerOperatingState 1.3.6.1.4.1.224.5.14
This variable will indicate operating status of the server: IDLE - all 0 The bit # (LSB = 0): REM - bit 0 on CRS - bit 1 on RPS - bit 2 on LBS - bit 3 on
Status: mandatory Access: read-only
OBJECT-TYPE    
  BITMAP  

rmServerAdminParameters 1.3.6.1.4.1.224.5.15
The required bit per event disabled/enabled. The bit # (LSB = 0): Nullevent(0), Nodenoresponseevent(1), Pollprocessfailevent(2), Criticnodejoinedringevent(3), Noderemovedevent(4), Activemonitorerrorevent(5), Newactivemonitorevent(6), Naunchangeevent(7), Claimtokenevent(8), Ringpurgeevent(9), Activemonitorpresentevent(10), Standbymonitorpresentevent(11), Softerrorreportevent(12), Ringstatusevent(13), Congestthresholdexccededevent(14), Congestthresholdendedevent(15), Nonisolatingthresholdexccededevent(16), Impendthresholdexccededevent(17), Excessivethresholdexcededevent(18), Errorratedecayevent(19), Adaptererrorevent(20), Responseevent(21), Pollprocessevent(22), Beaconevent(23), Nodeleftringevent(24), Nodejoinedringevent(25), Criticnodeleftringevent(26)
Status: mandatory Access: read-write
OBJECT-TYPE    
  BITMAP  

rmServerOperatingParameters 1.3.6.1.4.1.224.5.16
The required bit per event disabled/enabled. The bit # (LSB = 0): Nullevent(0), Nodenoresponseevent(1), Pollprocessfailevent(2), Criticnodejoinedringevent(3), Noderemovedevent(4), Activemonitorerrorevent(5), Newactivemonitorevent(6), Naunchangeevent(7), Claimtokenevent(8), Ringpurgeevent(9), Activemonitorpresentevent(10), Standbymonitorpresentevent(11), Softerrorreportevent(12), Ringstatusevent(13), Congestthresholdexccededevent(14), Congestthresholdendedevent(15), Nonisolatingthresholdexccededevent(16), Impendthresholdexccededevent(17), Excessivethresholdexcededevent(18), Errorratedecayevent(19), Adaptererrorevent(20), Responseevent(21), Pollprocessevent(22), Beaconevent(23), Nodeleftringevent(24), Nodejoinedringevent(25), Criticnodeleftringevent(26)
Status: mandatory Access: read-only
OBJECT-TYPE    
  BITMAP  

rmDeviceStatusTable 1.3.6.1.4.1.224.5.17
A table containing device parameters and configuration.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    RmDeviceEntry

rmDeviceEntry 1.3.6.1.4.1.224.5.17.1
An entry containing device parameters and configuration. The index to the table is the MAC address of the device.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  RmDeviceEntry  

rmDeviceMacAddress 1.3.6.1.4.1.224.5.17.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  PhysAddress  

rmDeviceUpstream 1.3.6.1.4.1.224.5.17.1.2
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  PhysAddress  

rmDeviceAdminState 1.3.6.1.4.1.224.5.17.1.3
The required state of the adapter. - only removed is supported.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER removed(4)  

rmDeviceOperateState 1.3.6.1.4.1.224.5.17.1.4
The operating state of the adapter.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER open(1), closed(2), removed(4), neverInserted(8)  

rmDevicePhysLocation 1.3.6.1.4.1.224.5.17.1.5
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

rmDeviceGroupAddress 1.3.6.1.4.1.224.5.17.1.6
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

rmDeviceFunctionAddress 1.3.6.1.4.1.224.5.17.1.7
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

rmDeviceProductID 1.3.6.1.4.1.224.5.17.1.8
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

rmDeviceStationID 1.3.6.1.4.1.224.5.17.1.9
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

rmDeviceStationStatus 1.3.6.1.4.1.224.5.17.1.10
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

rmDeviceFunctionClass 1.3.6.1.4.1.224.5.17.1.11
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

rmDeviceAccessPriority 1.3.6.1.4.1.224.5.17.1.12
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

rmDeviceMicroLevel 1.3.6.1.4.1.224.5.17.1.13
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

rmDeviceMonitored 1.3.6.1.4.1.224.5.17.1.14
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

rmDeviceDaysAllowed 1.3.6.1.4.1.224.5.17.1.15
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

rmDeviceHoursAllowed 1.3.6.1.4.1.224.5.17.1.16
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

rmRingPollProcessStatus 1.3.6.1.4.1.224.5.18
This variable will give the data structure describing the poll process status of the ring.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

rmRingNumber 1.3.6.1.4.1.224.5.35
This variable will give the local ring number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

rmRingSoftErrorTimer 1.3.6.1.4.1.224.5.36
This variable will give the ring soft error timer (in units of 10 milliseconds).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

rmRingIsolatingTab 1.3.6.1.4.1.224.5.37
This variable will give the ring isolating table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

rmRingCongestTab 1.3.6.1.4.1.224.5.38
This variable will give the ring congestion table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

rmRingNonIsolatingTab 1.3.6.1.4.1.224.5.39
This variable will give the ring non isolating table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

rmRingAutoRemove 1.3.6.1.4.1.224.5.42
This variable will enable/disable auto removal of a node when the isolating threshold is exceeded or the congestion threshold is exceeded.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

rmRingAllowedDaysPartition1 1.3.6.1.4.1.224.5.43
This variable is the first partition in the days time exis. The partitions define ranges in units of days in which some device are allowed to enter the ring and some are not.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..7  

rmRingAllowedDaysPartition2 1.3.6.1.4.1.224.5.44
This variable is the second partition in the days time exis. The partitions define ranges in units of days in which some devices are allowed to enter the ring and some are not. The value should be higher than Partition1
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..7  

rmRingAllowedHoursPartition1 1.3.6.1.4.1.224.5.45
This variable is the first partition in the hours time exis. The partitions define ranges in units of hours (1-24 hours) in which some devices are allowed to enter the ring and some are not.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..24  

rmRingAllowedHoursPartition2 1.3.6.1.4.1.224.5.46
This variable is the second partition in the hours time exis. The partitions define ranges in units of hours (1-24 hours) in which some devices are allowed to enter the ring and some are not. The value should be higher than Partition1.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..24  

rmServerPowerOn 1.3.6.1.4.1.224.5.47
This variable indicates if the server is powered on since the last poll.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

rmTRLastErrorClass 1.3.6.1.4.1.224.5.48
This var contains the error class of the last Token-Ring error reported by the agent.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER adapter-error(1), beaconing(2), iso-increasing(3), iso-excessive(4), iso-decay(5), congestion(6)  

rmTRLastErrorType 1.3.6.1.4.1.224.5.49
This var contains the error type of the last Token-Ring error, depending on the error class
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

rmTRFaultDomainNode1 1.3.6.1.4.1.224.5.50
This var contains the MAC address of the first node in the last error fault domain.
Status: mandatory Access: read-only
OBJECT-TYPE    
  PhysAddress  

rmTRFaultDomainNode2 1.3.6.1.4.1.224.5.51
This var contains the MAC address of the second node in the last error fault domain.
Status: mandatory Access: read-only
OBJECT-TYPE    
  PhysAddress  

rmIsoTresholdExceededCount 1.3.6.1.4.1.224.5.52
This var counts the total number that Isloating Treshold has been exceeded (exessive error status of the ring) since the agent is up or reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

rmNonIsoTresholdExceededCount 1.3.6.1.4.1.224.5.53
This var counts the total number that Non Isloating Treshold has been exceeded since the agent is up.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

rmCongestionTresholdExceededCount 1.3.6.1.4.1.224.5.54
This var counts the total number that Congestion Treshold has been exceeded since the agent is up.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

rmBeaconCounter 1.3.6.1.4.1.224.5.55
This var counts the total number of Beacons for the whole ring since the agent is up.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

rmSpareCounter 1.3.6.1.4.1.224.5.56
Spare Counter for future use
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

rmPurgeCounter 1.3.6.1.4.1.224.5.57
This var counts the total number of ring Purges since the agent is up.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

rmClaimCounter 1.3.6.1.4.1.224.5.58
This var counts the total number of Token Claims since the agent is up.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

rmAdapterResetCounter 1.3.6.1.4.1.224.5.59
This var counts the total number of times the agent adapter has to reset itself since the agent is up.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

rmLostFramesCounter 1.3.6.1.4.1.224.5.60
This var counts the total number of Lost Frames events for the whole ring since the agent is up.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

rmCongestionCounter 1.3.6.1.4.1.224.5.61
This var counts the total number of Congestion events for the whole ring since the agent is up.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

rmFrameCopyCounter 1.3.6.1.4.1.224.5.62
This var counts the total number of Frame Copy events for the whole ring since the agent is up.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

rmFrequencyErrorCounter 1.3.6.1.4.1.224.5.63
This var counts the total number of Frequency Error events for the whole ring since the agent is up.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

rmTokenCounter 1.3.6.1.4.1.224.5.64
This var counts the total number of Token error events for the whole ring since the agent is up.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

rmLineCounter 1.3.6.1.4.1.224.5.65
This var counts the total number of Line error events for the whole ring since the agent is up.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

rmInternalCounter 1.3.6.1.4.1.224.5.66
This var counts the total number of Internal error events for the whole ring since the agent is up.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

rmBurstCounter 1.3.6.1.4.1.224.5.67
This var counts the total number of Burst error events for the whole ring since the agent is up.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

rmARIFCICounter 1.3.6.1.4.1.224.5.68
This var counts the total number of ARI/FCI events for the whole ring since the agent is up.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

rmAbortCounter 1.3.6.1.4.1.224.5.69
This var counts the total number of Abort events for the whole ring since the agent is up.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

rmPollFailCounter 1.3.6.1.4.1.224.5.70
This var counts the total number of Poll Failed events for the whole ring since the agent is up.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

rmNoResponseCounter 1.3.6.1.4.1.224.5.71
This var counts the total number of No Response events for the whole ring since the agent is up.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

rmWholeRingCounters 1.3.6.1.4.1.224.5.72
This var counts a list of all the above counters (52-71) for convenience. Each counter occupies 32 bits of this structure in the order of the related variables. For internal use only.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

rmResetOldDevicesSetup 1.3.6.1.4.1.224.5.73
This var resets existing agent setup for all devices, e.g: monitored, not-allowed, etc.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

rmResetErrorCounters 1.3.6.1.4.1.224.5.74
This var resets existing agent error counters.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

rmSetCurrentTime 1.3.6.1.4.1.224.5.75
This var sets the current time (for security settings). The time is the number of seconds elapsed since midnight, December 31, 1899.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

rmRingFirstSplitConfiguration 1.3.6.1.4.1.224.5.76
This variable will give the first part of the ring configuration upto 256 bytes including header (for agents with limited buffer for a single octet). Retrieving this variable and several 'nexts' enables to compose the whole ring configuration.
Status: mandatory Access: read-only
OBJECT-TYPE    
  RING-CONFIGURATION  

rmRingNextSplitConfiguration 1.3.6.1.4.1.224.5.77
This variable will give the next part of the ring configuration relating to rmRingFirstSplitConfiguration or previous variable of this type. Upto 256 bytes are given (for agents with limited buffer for a single octet). See previous variable for more details.
Status: mandatory Access: read-only
OBJECT-TYPE    
  RING-CONFIGURATION