LANOPTICS-HUB-MIB

File: LANOPTICS-HUB-MIB.mib (13879 bytes)

Imported modules

RFC-1212 RFC1155-SMI RFC1213-MIB

Imported symbols

OBJECT-TYPE enterprises DisplayString

Defined Types

BITMAP  
INTEGER    

SnSlotsEntry  
SEQUENCE    
  snCardName DisplayString
  snCardDescr DisplayString
  snLLHwRevision INTEGER
  snLLSwRevision INTEGER
  snLLControl0 BITMAP
  snLLControl1 BITMAP
  snPollInf OCTET STRING
  snResetSlot INTEGER
  snPollInfCode OCTET STRING
  snAssCode OCTET STRING

SnHubSplitEntry  
SEQUENCE    
  snHubSplitStatus INTEGER

SnHubPSEntry  
SEQUENCE    
  snHubPSStatus INTEGER

SnHubFanEntry  
SEQUENCE    
  snHubFanStatus INTEGER

SnHubSlotsEntry  
SEQUENCE    
  snHubSlotConnected INTEGER
  snHubSlotFreqError INTEGER
  snHubSlotRevChanged INTEGER

SnGenPortsEntry  
SEQUENCE    
  snPortValue BITMAP

Defined Values

lanOptics 1.3.6.1.4.1.224
OBJECT IDENTIFIER    

lanOpticsHub 1.3.6.1.4.1.224.1
OBJECT IDENTIFIER    

snMaxSlots 1.3.6.1.4.1.224.1.1
The limit on the total number of slots that the Hub chassis has.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..16  

snSlotsNum 1.3.6.1.4.1.224.1.2
The actual number of slots occupied by the Hub modules .
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

snConfig 1.3.6.1.4.1.224.1.3
A list of all modules occupying slots in Hub in accordance with snSlotsNum.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

snLLActiveNMS 1.3.6.1.4.1.224.1.4
States whether the NMS-431X is active (1) or inactive (0). For internal use only. Should not be modified.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER active(1)  

snReset 1.3.6.1.4.1.224.1.5
Resets the management module of the Hub.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

snInternalID 1.3.6.1.4.1.224.1.6
The internal address of the management module (NMS-431X).
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

snDirtyBit 1.3.6.1.4.1.224.1.7
Low level description in bits for changes made in the system.
Status: mandatory Access: read-only
OBJECT-TYPE    
  BITMAP  

snSlotsTable 1.3.6.1.4.1.224.1.8
A list of slots entries. The number of entries is given by the value of snSlotsNum.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SnSlotsEntry

snSlotsEntry 1.3.6.1.4.1.224.1.8.1
A slot entry containing a high and low level description of the module in the slot.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SnSlotsEntry  

snCardName 1.3.6.1.4.1.224.1.8.1.1
Description of the card (module) name and type (IOM,LBM,BKM,NMS). It is set by Management entity . If not set by the Management entity - will response with HW,SW Rev.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

snCardDescr 1.3.6.1.4.1.224.1.8.1.2
Description of the card media, connectors and hardware.- not accesible in Low Level. In High Level will be set by the Management entity (for agents above v5.0)
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

snLLHwRevision 1.3.6.1.4.1.224.1.8.1.9
Low level description of the module's hardware revision (module type). For internal use only!
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

snLLSwRevision 1.3.6.1.4.1.224.1.8.1.10
Low level description of the module's software revision (module revision). For internal use only!
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

snLLControl0 1.3.6.1.4.1.224.1.8.1.14
Low level description of control actions on the module. Bit per port. For internal use only!
Status: mandatory Access: read-write
OBJECT-TYPE    
  BITMAP  

snLLControl1 1.3.6.1.4.1.224.1.8.1.15
Low level description of control actions on the module. Bit per port. For internal use only!.
Status: mandatory Access: read-write
OBJECT-TYPE    
  BITMAP  

snPollInf 1.3.6.1.4.1.224.1.8.1.29
Low level status description of this module represented by an internal structure. For internal use only.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING  

snResetSlot 1.3.6.1.4.1.224.1.8.1.38
Reset this slot (e.g. LBM module, NMS module). If this slot is the one the Agent occupies, reset the agent (same effect as snReset variable). If this is a special slot (0xF), reset the device mapped to this slot (e.g. the router ).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

snPollInfCode 1.3.6.1.4.1.224.1.8.1.41
This variable is set with assembly code for pollInf structure (per slot)
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

snAssCode 1.3.6.1.4.1.224.1.8.1.42
This variable is set with assembly code that should be perform immediatly (per slot)
Status: mandatory Access: read-write
OBJECT-TYPE    
  OCTET STRING  

snPairAddress 1.3.6.1.4.1.224.1.9
Low level port address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

snPairData 1.3.6.1.4.1.224.1.10
Low level port data. The value of this variable is read/written from/to the I/O address in snPairAddress variable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

snHubSplitTable 1.3.6.1.4.1.224.1.11
Status of each split card.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SnHubSplitEntry

snHubSplitEntry 1.3.6.1.4.1.224.1.11.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SnHubSplitEntry  

snHubSplitStatus 1.3.6.1.4.1.224.1.11.1.1
This variable describes the status of this split module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER splitted(1), missing(2)  

snHubPSTable 1.3.6.1.4.1.224.1.12
Status of each Power supply.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SnHubPSEntry

snHubPSEntry 1.3.6.1.4.1.224.1.12.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SnHubPSEntry  

snHubPSStatus 1.3.6.1.4.1.224.1.12.1.1
This variable describes the status of this Power Supply.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER malfunctioning(1), missing(2)  

snHubFanTable 1.3.6.1.4.1.224.1.13
Status of each Fan.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SnHubFanEntry

snHubFanEntry 1.3.6.1.4.1.224.1.13.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SnHubFanEntry  

snHubFanStatus 1.3.6.1.4.1.224.1.13.1.1
This variable describes the status of this Fan.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER malfunctioning(1), missing(2)  

snHubSlotsTable 1.3.6.1.4.1.224.1.14
Hub's alerts related information per slot
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SnHubSlotsEntry

snHubSlotsEntry 1.3.6.1.4.1.224.1.14.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SnHubSlotsEntry  

snHubSlotConnected 1.3.6.1.4.1.224.1.14.1.1
This variable signifies that this entire slot was disconnected or reconnected by a management entity.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER disconnected(1)  

snHubSlotFreqError 1.3.6.1.4.1.224.1.14.1.2
This variable signifies that this slot frequency differs from the back-plane's.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER slot-4M(4), slot-16M(16)  

snHubSlotRevChanged 1.3.6.1.4.1.224.1.14.1.3
This variable signifies that this slot SW revision has changed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unchanged(1)  

snCompanionHW 1.3.6.1.4.1.224.1.15
Gives the value of the Hardware and software revision that is sharing the (PC) bus with the agent, e.g, a Cisco Router PC-Card. If no hardware exists, the value should be 0xFF.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

snCompanionReset 1.3.6.1.4.1.224.1.16
Send Reset to the companion hardware(cisco router)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

snCompanionStatus 1.3.6.1.4.1.224.1.17
Gives the companion status. For cisco router: Bit0 - Lan Active led(1-on,0-off) Bit2 - ISDN present bit Bit3 - O.k. Led(1-on,0-off)
Status: mandatory Access: read-only
OBJECT-TYPE    
  BITMAP  

snGenPortsTable 1.3.6.1.4.1.224.1.18
A table of all possible I/O ports in address range is 0xC000 - 0xFFFF
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SnGenPortsEntry

snGenPortsEntry 1.3.6.1.4.1.224.1.18.1
An I/O port entry. Each byte of the I/O address is represented by one index digit; e.g, instance 255.12 is I/O address (port) 0xFF0C.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SnGenPortsEntry  

snPortValue 1.3.6.1.4.1.224.1.18.1.1
The I/O port value.
Status: mandatory Access: read-write
OBJECT-TYPE    
  BITMAP