LANOPTICS-HUB-MIB
File:
LANOPTICS-HUB-MIB.mib (13879 bytes)
Imported modules
Imported symbols
Defined Types
SnSlotsEntry |
|
SEQUENCE |
|
|
|
|
snCardName |
DisplayString |
|
|
snCardDescr |
DisplayString |
|
|
snLLHwRevision |
INTEGER |
|
|
snLLSwRevision |
INTEGER |
|
|
snLLControl0 |
BITMAP |
|
|
snLLControl1 |
BITMAP |
|
|
snPollInf |
OCTET STRING |
|
|
snResetSlot |
INTEGER |
|
|
snPollInfCode |
OCTET STRING |
|
|
snAssCode |
OCTET STRING |
|
SnHubSplitEntry |
|
SEQUENCE |
|
|
|
|
snHubSplitStatus |
INTEGER |
|
SnHubPSEntry |
|
SEQUENCE |
|
|
|
|
snHubPSStatus |
INTEGER |
|
SnHubFanEntry |
|
SEQUENCE |
|
|
|
|
snHubFanStatus |
INTEGER |
|
SnHubSlotsEntry |
|
SEQUENCE |
|
|
|
|
snHubSlotConnected |
INTEGER |
|
|
snHubSlotFreqError |
INTEGER |
|
|
snHubSlotRevChanged |
INTEGER |
|
SnGenPortsEntry |
|
SEQUENCE |
|
|
|
|
snPortValue |
BITMAP |
|
Defined Values
snMaxSlots |
1.3.6.1.4.1.224.1.1 |
The limit on the total number of slots that the
Hub chassis has. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
1..16 |
|
snSlotsNum |
1.3.6.1.4.1.224.1.2 |
The actual number of slots occupied by the Hub modules . |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
snConfig |
1.3.6.1.4.1.224.1.3 |
A list of all modules occupying slots in Hub
in accordance with snSlotsNum. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
snLLActiveNMS |
1.3.6.1.4.1.224.1.4 |
States whether the NMS-431X is active (1) or
inactive (0). For internal use only.
Should not be modified. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
active(1) |
|
snReset |
1.3.6.1.4.1.224.1.5 |
Resets the management module of the Hub. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
snInternalID |
1.3.6.1.4.1.224.1.6 |
The internal address of the management module (NMS-431X). |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
snDirtyBit |
1.3.6.1.4.1.224.1.7 |
Low level description in bits for changes made
in the system. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
BITMAP |
|
|
snSlotsTable |
1.3.6.1.4.1.224.1.8 |
A list of slots entries. The number of entries
is given by the value of snSlotsNum. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
SnSlotsEntry |
|
snSlotsEntry |
1.3.6.1.4.1.224.1.8.1 |
A slot entry containing a high and low
level description of the module in the slot. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SnSlotsEntry |
|
|
snCardName |
1.3.6.1.4.1.224.1.8.1.1 |
Description of the card (module) name and type
(IOM,LBM,BKM,NMS). It is set by Management entity .
If not set by the Management entity - will response with HW,SW Rev. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
snCardDescr |
1.3.6.1.4.1.224.1.8.1.2 |
Description of the card media, connectors and
hardware.- not accesible in Low Level. In High Level will be set
by the Management entity (for agents above v5.0) |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
snLLHwRevision |
1.3.6.1.4.1.224.1.8.1.9 |
Low level description of the module's hardware
revision (module type). For internal use only! |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
snLLSwRevision |
1.3.6.1.4.1.224.1.8.1.10 |
Low level description of the module's software
revision (module revision). For internal use only! |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
snLLControl0 |
1.3.6.1.4.1.224.1.8.1.14 |
Low level description of control actions on the
module. Bit per port. For internal use only! |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
BITMAP |
|
|
snLLControl1 |
1.3.6.1.4.1.224.1.8.1.15 |
Low level description of control actions on the
module. Bit per port. For internal use only!. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
BITMAP |
|
|
snPollInf |
1.3.6.1.4.1.224.1.8.1.29 |
Low level status description of this module
represented by an internal structure. For internal use only. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
snResetSlot |
1.3.6.1.4.1.224.1.8.1.38 |
Reset this slot (e.g. LBM module, NMS module). If this slot
is the one the Agent occupies, reset the agent (same effect
as snReset variable).
If this is a special slot (0xF), reset the device mapped
to this slot (e.g. the router ). |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
snPollInfCode |
1.3.6.1.4.1.224.1.8.1.41 |
This variable is set with assembly code for pollInf structure (per slot) |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
snAssCode |
1.3.6.1.4.1.224.1.8.1.42 |
This variable is set with assembly code that should be perform immediatly (per slot) |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
snPairAddress |
1.3.6.1.4.1.224.1.9 |
Low level port address. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
snPairData |
1.3.6.1.4.1.224.1.10 |
Low level port data. The value of this variable is read/written
from/to the I/O address in snPairAddress variable. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
snHubSplitEntry |
1.3.6.1.4.1.224.1.11.1 |
Tok_String |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SnHubSplitEntry |
|
|
snHubSplitStatus |
1.3.6.1.4.1.224.1.11.1.1 |
This variable describes the status of this split module. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
splitted(1), missing(2) |
|
snHubPSTable |
1.3.6.1.4.1.224.1.12 |
Status of each Power supply. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
SnHubPSEntry |
|
snHubPSEntry |
1.3.6.1.4.1.224.1.12.1 |
Tok_String |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SnHubPSEntry |
|
|
snHubPSStatus |
1.3.6.1.4.1.224.1.12.1.1 |
This variable describes the status of this Power Supply. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
malfunctioning(1), missing(2) |
|
snHubFanTable |
1.3.6.1.4.1.224.1.13 |
Status of each Fan. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
SnHubFanEntry |
|
snHubFanEntry |
1.3.6.1.4.1.224.1.13.1 |
Tok_String |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SnHubFanEntry |
|
|
snHubFanStatus |
1.3.6.1.4.1.224.1.13.1.1 |
This variable describes the status of this Fan. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
malfunctioning(1), missing(2) |
|
snHubSlotsTable |
1.3.6.1.4.1.224.1.14 |
Hub's alerts related information per slot |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
SnHubSlotsEntry |
|
snHubSlotsEntry |
1.3.6.1.4.1.224.1.14.1 |
Tok_String |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SnHubSlotsEntry |
|
|
snHubSlotConnected |
1.3.6.1.4.1.224.1.14.1.1 |
This variable signifies that this entire slot
was disconnected or reconnected by a management entity. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
disconnected(1) |
|
snHubSlotFreqError |
1.3.6.1.4.1.224.1.14.1.2 |
This variable signifies that this slot frequency
differs from the back-plane's. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
slot-4M(4), slot-16M(16) |
|
snHubSlotRevChanged |
1.3.6.1.4.1.224.1.14.1.3 |
This variable signifies that this slot SW revision
has changed. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
unchanged(1) |
|
snCompanionHW |
1.3.6.1.4.1.224.1.15 |
Gives the value of the Hardware and software revision
that is sharing the (PC) bus with the agent, e.g,
a Cisco Router PC-Card. If no hardware exists, the value
should be 0xFF. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
snCompanionReset |
1.3.6.1.4.1.224.1.16 |
Send Reset to the companion hardware(cisco router) |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
snCompanionStatus |
1.3.6.1.4.1.224.1.17 |
Gives the companion status.
For cisco router: Bit0 - Lan Active led(1-on,0-off)
Bit2 - ISDN present bit
Bit3 - O.k. Led(1-on,0-off) |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
BITMAP |
|
|
snGenPortsTable |
1.3.6.1.4.1.224.1.18 |
A table of all possible I/O ports in address range is 0xC000 - 0xFFFF |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
SnGenPortsEntry |
|
snGenPortsEntry |
1.3.6.1.4.1.224.1.18.1 |
An I/O port entry. Each byte of the I/O address is represented
by one index digit; e.g, instance 255.12 is I/O address (port) 0xFF0C. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SnGenPortsEntry |
|
|
snPortValue |
1.3.6.1.4.1.224.1.18.1.1 |
The I/O port value. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
BITMAP |
|
|