Juniper-DS3-MIB

File: Juniper-DS3-MIB.mib (28780 bytes)

Imported modules

SNMPv2-SMI SNMPv2-CONF IF-MIB
SNMPv2-TC Juniper-TC Juniper-MIBs
PerfHist-TC-MIB DS3-MIB

Imported symbols

MODULE-IDENTITY OBJECT-TYPE Integer32
MODULE-COMPLIANCE OBJECT-GROUP ifIndex
InterfaceIndexOrZero TruthValue RowStatus
DisplayString JuniNextIfIndex juniMibs
PerfCurrentCount PerfIntervalCount PerfTotalCount
dsx3FarEndCurrentEntry dsx3FarEndIntervalEntry dsx3FarEndTotalEntry
dsx3FarEndConfigEntry

Defined Types

JuniDsx3ConfigEntry  
SEQUENCE    
  juniDsx3LineLength Integer32
  juniDsx3LineType INTEGER
  juniDsx3CellScramblerConfig INTEGER
  juniDsx3Channelization TruthValue
  juniDsx3InterfaceType INTEGER
  juniDsx3Application INTEGER
  juniDsx3Ds3Channel INTEGER
  juniDsx3LowerIfIndex InterfaceIndexOrZero
  juniDsx3RowStatus RowStatus
  juniDsx3Ds3DsuMode INTEGER
  juniDsx3Ds3BandwidthLimit INTEGER
  juniDsx3Ds3DsuScrambleMode INTEGER
  juniDsx3MdlCarrier INTEGER
  juniDsx3MdlTransmit INTEGER
  juniDsx3MdlEic DisplayString
  juniDsx3MdlLic DisplayString
  juniDsx3MdlFic DisplayString
  juniDsx3MdlUnit DisplayString
  juniDsx3MdlPfi DisplayString
  juniDsx3MdlPort DisplayString
  juniDsx3MdlGenerator DisplayString

JuniDsx3FarEndCurrentEntry  
SEQUENCE    
  juniDsx3FarEndCurrentInvalidSeconds PerfCurrentCount

JuniDsx3FarEndIntervalEntry  
SEQUENCE    
  juniDsx3FarEndIntervalInvalidSeconds PerfIntervalCount

JuniDsx3FarEndTotalEntry  
SEQUENCE    
  juniDsx3FarEndTotalInvalidSeconds PerfTotalCount

JuniDsx3FarEndConfigEntry  
SEQUENCE    
  juniDsx3FarEndPortNumber DisplayString
  juniDsx3FarEndGeneratorNumber DisplayString
  juniDsx3FarEndCarrier INTEGER

Defined Values

juniDs3MIB 1.3.6.1.4.1.4874.2.2.4
The DS3 MIB for the Juniper Networks enterprise. This MIB contains managed objects for DS3/E3 interfaces. Management objects are provided to supplement those found in the standard DS3-MIB (RFC 2496).
MODULE-IDENTITY    

juniDs3Objects 1.3.6.1.4.1.4874.2.2.4.1
OBJECT IDENTIFIER    

juniDsx3ConfigTable 1.3.6.1.4.1.4874.2.2.4.1.1
This table contains entries for DS3/E3 interfaces present in the system.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    JuniDsx3ConfigEntry

juniDsx3ConfigEntry 1.3.6.1.4.1.4874.2.2.4.1.1.1
Each entry describes the characteristics of an DS3/E3 interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  JuniDsx3ConfigEntry  

juniDsx3LineLength 1.3.6.1.4.1.4874.2.2.4.1.1.1.1
The length of the DS3/E3 line in meters. This objects provides information for line build out circuitry. This object is only useful if the interface has configurable line build out circuitry.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 0..137  

juniDsx3LineType 1.3.6.1.4.1.4874.2.2.4.1.1.1.2
This variable indicates the variety of DS3 C-bit or E3 application implementing this interface. The type of interface affects the interpretation of the usage and error statistics. The rate of DS3 is 44.736 Mbps and E3 is 34.368 Mbps. The dsx3ClearChannel value means that the C-bits are not used except for sending/receiving AIS. Note that this object represents the actual line type when the corresponding value of dsx3LineType is dsx3other(1). The values, in sequence, describe: TITLE: SPECIFICATION: dsx3M23 ANSI T1.107-1988 dsx3SYNTRAN ANSI T1.107-1988 dsx3CbitParity ANSI T1.107a-1989 dsx3ClearChannel ANSI T1.102-1987 e3G832 ITU-T G.832 e3Framed ITU-T G.751 e3Plcp ETSI T/NA(91)18. dsx3M23Plcp ATM Forum af-phy-0054.000 dsx3CbitParityPlcp ATM Forum af-phy-0054.000
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER juniDsx3other(1), juniDsx3M23(2), juniDsx3SYNTRAN(3), juniDsx3CbitParity(4), juniDsx3ClearChannel(5), juniE3G832(6), juniE3Framed(7), juniE3Plcp(8), juniDsx3M23Plcp(18), juniDsx3CbitParityPlcp(20)  

juniDsx3CellScramblerConfig 1.3.6.1.4.1.4874.2.2.4.1.1.1.3
This variable indicates the state of the ATM cell scrambler for interfaces which support ATM over DS3 or E3. For interfaces which do not support ATM, this object returns the value notSupported(3).
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER scramblerOn(1), scramblerOff(2), notSupported(3)  

juniDsx3Channelization 1.3.6.1.4.1.4874.2.2.4.1.1.1.4
The channelization setting for this DS3 interface; true(1) indicates channelization, false(2) indicates no channelization.
Status: current Access: read-create
OBJECT-TYPE    
  TruthValue  

juniDsx3InterfaceType 1.3.6.1.4.1.4874.2.2.4.1.1.1.5
The DS3 interface type setting.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER ds3T3(0), ds3E3(1)  

juniDsx3Application 1.3.6.1.4.1.4874.2.2.4.1.1.1.6
The interface application setting.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER ds3FrameOverDs3(0), ds3AtmOverDs3(1)  

juniDsx3Ds3Channel 1.3.6.1.4.1.4874.2.2.4.1.1.1.7
The DS3 channel setting. The range of channel settings depends on the line rate of the underlying interface.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 1..28  

juniDsx3LowerIfIndex 1.3.6.1.4.1.4874.2.2.4.1.1.1.8
The ifIndex of the interface over which this DS3 interface is to be layered. A value of zero indicates no layering. An implementation may choose to require that a nonzero value be configured at entry creation.
Status: current Access: read-create
OBJECT-TYPE    
  InterfaceIndexOrZero  

juniDsx3RowStatus 1.3.6.1.4.1.4874.2.2.4.1.1.1.9
Controls creation/deletion of entries in this table according to the RowStatus textual convention, constrained to support setting the following values only: createAndGo destroy To create an entry in this table, the following entry objects MUST be explicitly configured: juniDsx3RowStatus juniDsx3LowerIfIndex In addition, when creating an entry the following conditions must hold: A value for ifIndex must have been determined previously, by reading juniDsx3NextIfIndex. The interface identified by juniDsx3LowerIfIndex must exist. A corresponding entry in ifTable/ifXTable/juniIfTable is created/ destroyed as a result of creating/destroying an entry in this table.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

juniDsx3Ds3DsuMode 1.3.6.1.4.1.4874.2.2.4.1.1.1.10
The DSU configuration setting for this entry.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER ds3DsuModeNone(0), ds3DsuLarsCom(2), ds3DsuDigitalLink(4)  

juniDsx3Ds3BandwidthLimit 1.3.6.1.4.1.4874.2.2.4.1.1.1.11
The DSU bandwidth configuration for this entry.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..44210  

juniDsx3Ds3DsuScrambleMode 1.3.6.1.4.1.4874.2.2.4.1.1.1.12
The DSU scramble mode setting for this entry.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER ds3DsuScrambleDisabled(0), ds3DsuScrambleEnable(1)  

juniDsx3MdlCarrier 1.3.6.1.4.1.4874.2.2.4.1.1.1.13
Specifies the interface is used in carrier environment.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

juniDsx3MdlTransmit 1.3.6.1.4.1.4874.2.2.4.1.1.1.14
Specifies transmission enabling.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER path(1), idlesignal(2), pathIdlesignal(3), testsignal(4), pathTestsignal(5), idlesignalTestsignal(6), pathIdlesignalTestsignal(7), none(8)  

juniDsx3MdlEic 1.3.6.1.4.1.4874.2.2.4.1.1.1.15
This is the equipment identification code.
Status: current Access: read-create
OBJECT-TYPE    
  DisplayString Size(0..10)  

juniDsx3MdlLic 1.3.6.1.4.1.4874.2.2.4.1.1.1.16
This is the location identification code.
Status: current Access: read-create
OBJECT-TYPE    
  DisplayString Size(0..11)  

juniDsx3MdlFic 1.3.6.1.4.1.4874.2.2.4.1.1.1.17
This is the frame identification code.
Status: current Access: read-create
OBJECT-TYPE    
  DisplayString Size(0..10)  

juniDsx3MdlUnit 1.3.6.1.4.1.4874.2.2.4.1.1.1.18
This is the unit identification code.
Status: current Access: read-create
OBJECT-TYPE    
  DisplayString Size(0..6)  

juniDsx3MdlPfi 1.3.6.1.4.1.4874.2.2.4.1.1.1.19
This is the facility identification code to send in the MDL path message.
Status: current Access: read-create
OBJECT-TYPE    
  DisplayString Size(0..38)  

juniDsx3MdlPort 1.3.6.1.4.1.4874.2.2.4.1.1.1.20
This is the equipment port number to send in the MDL idle signal message.
Status: current Access: read-create
OBJECT-TYPE    
  DisplayString Size(0..38)  

juniDsx3MdlGenerator 1.3.6.1.4.1.4874.2.2.4.1.1.1.21
This is the generator number to send in the MDL test signal message.
Status: current Access: read-create
OBJECT-TYPE    
  DisplayString Size(0..38)  

juniDs3NextIfIndex 1.3.6.1.4.1.4874.2.2.4.1.2
Coordinate ifIndex value allocation for entries in juniDsx3ConfigTable. A GET of this object returns the next available ifIndex value to be used to create an entry in the associated interface table; or zero, if no valid ifIndex value is available. This object also returns a value of zero when it is the lexicographic successor of a varbind presented in an SNMP GETNEXT or GETBULK request, for which circumstance it is assumed that ifIndex allocation is unintended. Successive GETs will typically return different values, thus avoiding collisions among cooperating management clients seeking to create table entries simultaneously.
Status: current Access: read-only
OBJECT-TYPE    
  JuniNextIfIndex  

juniDsx3FarEndCurrentTable 1.3.6.1.4.1.4874.2.2.4.1.3
This table contains entries for DS3/E3 interfaces present in the system.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    JuniDsx3FarEndCurrentEntry

juniDsx3FarEndCurrentEntry 1.3.6.1.4.1.4874.2.2.4.1.3.1
Each entry describes the characteristics of an DS3/E3 interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  JuniDsx3FarEndCurrentEntry  

juniDsx3FarEndCurrentInvalidSeconds 1.3.6.1.4.1.4874.2.2.4.1.3.1.1
The counter associated with the number of Invalid Seconds encountered by a DS3/E3 interface in the current 15 minute interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfCurrentCount  

juniDsx3FarEndIntervalTable 1.3.6.1.4.1.4874.2.2.4.1.4
This table contains entries for DS3/E3 interfaces present in the system.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    JuniDsx3FarEndIntervalEntry

juniDsx3FarEndIntervalEntry 1.3.6.1.4.1.4874.2.2.4.1.4.1
Each entry describes the characteristics of an DS3/E3 interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  JuniDsx3FarEndIntervalEntry  

juniDsx3FarEndIntervalInvalidSeconds 1.3.6.1.4.1.4874.2.2.4.1.4.1.1
The counter associated with the number of Invalid Seconds encountered by a DS3/E3 interface in one of the previous 96 individual 15 minute intervals.
Status: current Access: read-only
OBJECT-TYPE    
  PerfIntervalCount  

juniDsx3FarEndTotalTable 1.3.6.1.4.1.4874.2.2.4.1.5
This table contains entries for DS3/E3 interfaces present in the system.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    JuniDsx3FarEndTotalEntry

juniDsx3FarEndTotalEntry 1.3.6.1.4.1.4874.2.2.4.1.5.1
Each entry describes the characteristics of an DS3/E3 interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  JuniDsx3FarEndTotalEntry  

juniDsx3FarEndTotalInvalidSeconds 1.3.6.1.4.1.4874.2.2.4.1.5.1.1
The counter associated with the number of Invalid Seconds encountered by a DS3/E3 interface in the previous 24 hour interval.
Status: current Access: read-only
OBJECT-TYPE    
  PerfTotalCount  

juniDsx3FarEndConfigTable 1.3.6.1.4.1.4874.2.2.4.1.6
This table contains entries for DS3/E3 interfaces present in the system.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    JuniDsx3FarEndConfigEntry

juniDsx3FarEndConfigEntry 1.3.6.1.4.1.4874.2.2.4.1.6.1
Each entry describes the far end configuration characteristics of an DS3/E3 interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  JuniDsx3FarEndConfigEntry  

juniDsx3FarEndPortNumber 1.3.6.1.4.1.4874.2.2.4.1.6.1.1
This code identifies the port number of the Far End DS3. It is sent within the Idle Signal Message.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..38)  

juniDsx3FarEndGeneratorNumber 1.3.6.1.4.1.4874.2.2.4.1.6.1.2
This code identifies the Far End DS3 Generator Number. It is sent within the Test Signal Message.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..38)  

juniDsx3FarEndCarrier 1.3.6.1.4.1.4874.2.2.4.1.6.1.3
Specifies the interface is used in carrier environment. It is sent with MDL messages.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

juniDs3Conformance 1.3.6.1.4.1.4874.2.2.4.4
OBJECT IDENTIFIER    

juniDs3Compliances 1.3.6.1.4.1.4874.2.2.4.4.1
OBJECT IDENTIFIER    

juniDs3Groups 1.3.6.1.4.1.4874.2.2.4.4.2
OBJECT IDENTIFIER    

juniDs3Compliance 1.3.6.1.4.1.4874.2.2.4.4.1.1
Obsolete compliance statement for entities which implement the Juniper DS3/E3 MIB. This statement became obsolete when support was added for line type and cell scrambler objects.
Status: obsolete Access: read-write
MODULE-COMPLIANCE    

juniDs3Compliance2 1.3.6.1.4.1.4874.2.2.4.4.1.2
Obsolete compliance statement for entities which implement the Juniper DS3/E3 MIB. This statement became obsolete when support was added for DSU objects.
Status: obsolete Access: read-write
MODULE-COMPLIANCE    

juniDs3Compliance3 1.3.6.1.4.1.4874.2.2.4.4.1.3
Obsolete compliance statement for entities which implement the Juniper DS3/E3 MIB. This statement became obsolete when support was added for dynamic DS3 interface objects.
Status: obsolete Access: read-write
MODULE-COMPLIANCE    

juniDs3Compliance4 1.3.6.1.4.1.4874.2.2.4.4.1.4
Obsolete compliance statement for entities which implement the Juniper DS3/E3 MIB. This statement became obsolete when far end invalid seconds objects and more configuration objects were added.
Status: obsolete Access: read-write
MODULE-COMPLIANCE    

juniDs3Compliance5 1.3.6.1.4.1.4874.2.2.4.4.1.5
Obsolete compliance statement for entities which implement the Juniper DS3/E3 MIB. This statement became obsolete when support was added for far end generator number, port number and carrier.
Status: obsolete Access: read-write
MODULE-COMPLIANCE    

juniDs3Compliance6 1.3.6.1.4.1.4874.2.2.4.4.1.6
The compliance statement for entities which implement the Juniper DS3/E3 MIB.
Status: current Access: read-write
MODULE-COMPLIANCE    

juniDs3Group 1.3.6.1.4.1.4874.2.2.4.4.2.1
Obsolete collection of objects providing management of DS3/E3 interfaces in a Juniper product. This group became obsolete when support was added for line type and cell scrambler objects.
Status: obsolete Access: read-write
OBJECT-GROUP    

juniDs3Group2 1.3.6.1.4.1.4874.2.2.4.4.2.2
Obsolete collection of objects providing management of DS3/E3 interfaces in a Juniper product. This group became obsolete when support was added for DSU configuration objects.
Status: obsolete Access: read-write
OBJECT-GROUP    

juniDs3Group3 1.3.6.1.4.1.4874.2.2.4.4.2.3
Obsolete collection of objects providing management of DS3/E3 interfaces in a Juniper product. This group became obsolete when support was added for dynamic DS3 interface objects.
Status: obsolete Access: read-write
OBJECT-GROUP    

juniDs3Group4 1.3.6.1.4.1.4874.2.2.4.4.2.4
Obsolete collection of objects providing management of DS3/E3 interfaces in a Juniper product. This group became obsolete when more configuration objects were added.
Status: obsolete Access: read-write
OBJECT-GROUP    

juniDs3Group5 1.3.6.1.4.1.4874.2.2.4.4.2.5
A collection of objects providing management of DS3/E3 interfaces in a Juniper product.
Status: current Access: read-write
OBJECT-GROUP    

juniDs3FarEndGroup 1.3.6.1.4.1.4874.2.2.4.4.2.6
Obsolete collection of objects providing remote statistics information applicable to DS3 interfaces in a Juniper product. This group became obsolete when remote port number, generator number and carrier objects were added.
Status: obsolete Access: read-write
OBJECT-GROUP    

juniDs3FarEndGroup2 1.3.6.1.4.1.4874.2.2.4.4.2.7
A collection of objects providing remote statistics information applicable to DS3 interfaces in a Juniper product.
Status: current Access: read-write
OBJECT-GROUP