IT-WATCHDOGS-MIB-V3

File: IT-WATCHDOGS-MIB-V3.mib (350359 bytes)

Imported modules

SNMPv2-TC SNMPv2-SMI

Imported symbols

DisplayString MODULE-IDENTITY OBJECT-TYPE
enterprises Gauge32 Integer32
NOTIFICATION-TYPE

Defined Types

ClimateEntry  
SEQUENCE    
  climateIndex INTEGER
  climateSerial DisplayString
  climateName DisplayString
  climateAvail Gauge32
  climateTempC INTEGER
  climateTempF INTEGER
  climateHumidity INTEGER
  climateLight INTEGER
  climateAirflow INTEGER
  climateSound INTEGER
  climateIO1 INTEGER
  climateIO2 INTEGER
  climateIO3 INTEGER
  climateDewPointC INTEGER
  climateDewPointF INTEGER

PowMonEntry  
SEQUENCE    
  powMonIndex INTEGER
  powMonSerial DisplayString
  powMonName DisplayString
  powMonAvail Gauge32
  powMonkWattHrs Gauge32
  powMonVolts Gauge32
  powMonVoltMax Gauge32
  powMonVoltMin Gauge32
  powMonVoltPeak Gauge32
  powMonDeciAmps Gauge32
  powMonRealPower Gauge32
  powMonApparentPower Gauge32
  powMonPowerFactor INTEGER
  powMonOutlet1 INTEGER
  powMonOutlet2 INTEGER
  powMonOutlet1StatusTime Gauge32
  powMonOutlet2StatusTime Gauge32

TempSensorEntry  
SEQUENCE    
  tempSensorIndex INTEGER
  tempSensorSerial DisplayString
  tempSensorName DisplayString
  tempSensorAvail Gauge32
  tempSensorTempC INTEGER
  tempSensorTempF INTEGER

AirFlowSensorEntry  
SEQUENCE    
  airFlowSensorIndex INTEGER
  airFlowSensorSerial DisplayString
  airFlowSensorName DisplayString
  airFlowSensorAvail Gauge32
  airFlowSensorTempC INTEGER
  airFlowSensorTempF INTEGER
  airFlowSensorFlow INTEGER
  airFlowSensorHumidity INTEGER
  airFlowSensorDewPointC INTEGER
  airFlowSensorDewPointF INTEGER

Ctrl3ChDELTAEntry  
SEQUENCE    
  ctrl3ChDELTAIndex INTEGER
  ctrl3ChDELTASerial DisplayString
  ctrl3ChDELTAName DisplayString
  ctrl3ChDELTAAvail Gauge32
  ctrl3ChDELTAPowerChCount INTEGER
  ctrl3ChDELTADeciAmpsA Gauge32
  ctrl3ChDELTADeciAmpsB Gauge32
  ctrl3ChDELTADeciAmpsC Gauge32
  ctrl3ChDELTAkWattHrsTotal Gauge32
  ctrl3ChDELTARealPowerTotal Gauge32
  ctrl3ChDELTAkWattHrsAB Gauge32
  ctrl3ChDELTAVoltsAB Gauge32
  ctrl3ChDELTAVoltPeakAB Gauge32
  ctrl3ChDELTARealPowerAB Gauge32
  ctrl3ChDELTAApparentPowerAB Gauge32
  ctrl3ChDELTAPowerFactorAB INTEGER
  ctrl3ChDELTAkWattHrsBC Gauge32
  ctrl3ChDELTAVoltsBC Gauge32
  ctrl3ChDELTAVoltPeakBC Gauge32
  ctrl3ChDELTARealPowerBC Gauge32
  ctrl3ChDELTAApparentPowerBC Gauge32
  ctrl3ChDELTAPowerFactorBC INTEGER
  ctrl3ChDELTAkWattHrsCA Gauge32
  ctrl3ChDELTAVoltsCA Gauge32
  ctrl3ChDELTAVoltPeakCA Gauge32
  ctrl3ChDELTARealPowerCA Gauge32
  ctrl3ChDELTAApparentPowerCA Gauge32
  ctrl3ChDELTAPowerFactorCA INTEGER

DoorSensorEntry  
SEQUENCE    
  doorSensorIndex INTEGER
  doorSensorSerial DisplayString
  doorSensorName DisplayString
  doorSensorAvail Gauge32
  doorSensorStatus INTEGER

WaterSensorEntry  
SEQUENCE    
  waterSensorIndex INTEGER
  waterSensorSerial DisplayString
  waterSensorName DisplayString
  waterSensorAvail Gauge32
  waterSensorDampness INTEGER

CurrentMonitorEntry  
SEQUENCE    
  currentMonitorIndex INTEGER
  currentMonitorSerial DisplayString
  currentMonitorName DisplayString
  currentMonitorAvail Gauge32
  currentMonitorDeciAmps INTEGER

MillivoltMonitorEntry  
SEQUENCE    
  millivoltMonitorIndex INTEGER
  millivoltMonitorSerial DisplayString
  millivoltMonitorName DisplayString
  millivoltMonitorAvail Gauge32
  millivoltMonitorMV INTEGER

Pow3ChEntry  
SEQUENCE    
  pow3ChIndex INTEGER
  pow3ChSerial DisplayString
  pow3ChName DisplayString
  pow3ChAvail Gauge32
  pow3ChkWattHrsA Gauge32
  pow3ChVoltsA Gauge32
  pow3ChVoltMaxA Gauge32
  pow3ChVoltMinA Gauge32
  pow3ChVoltPeakA Gauge32
  pow3ChDeciAmpsA Gauge32
  pow3ChRealPowerA Gauge32
  pow3ChApparentPowerA Gauge32
  pow3ChPowerFactorA INTEGER
  pow3ChkWattHrsB Gauge32
  pow3ChVoltsB Gauge32
  pow3ChVoltMaxB Gauge32
  pow3ChVoltMinB Gauge32
  pow3ChVoltPeakB Gauge32
  pow3ChDeciAmpsB Gauge32
  pow3ChRealPowerB Gauge32
  pow3ChApparentPowerB Gauge32
  pow3ChPowerFactorB INTEGER
  pow3ChkWattHrsC Gauge32
  pow3ChVoltsC Gauge32
  pow3ChVoltMaxC Gauge32
  pow3ChVoltMinC Gauge32
  pow3ChVoltPeakC Gauge32
  pow3ChDeciAmpsC Gauge32
  pow3ChRealPowerC Gauge32
  pow3ChApparentPowerC Gauge32
  pow3ChPowerFactorC INTEGER
  pow3ChkWattHrsTotal Gauge32
  pow3ChRealPowerTotal Gauge32

OutletEntry  
SEQUENCE    
  outletIndex INTEGER
  outletSerial DisplayString
  outletName DisplayString
  outletAvail Gauge32
  outlet1Status INTEGER
  outlet2Status INTEGER

VsfcEntry  
SEQUENCE    
  vsfcIndex INTEGER
  vsfcSerial DisplayString
  vsfcName DisplayString
  vsfcAvail Gauge32
  vsfcSetPointC INTEGER
  vsfcSetPointF INTEGER
  vsfcFanSpeed INTEGER
  vsfcIntTempC INTEGER
  vsfcIntTempF INTEGER
  vsfcExt1TempC INTEGER
  vsfcExt1TempF INTEGER
  vsfcExt2TempC INTEGER
  vsfcExt2TempF INTEGER
  vsfcExt3TempC INTEGER
  vsfcExt3TempF INTEGER
  vsfcExt4TempC INTEGER
  vsfcExt4TempF INTEGER

Ctrl3ChEntry  
SEQUENCE    
  ctrl3ChIndex INTEGER
  ctrl3ChSerial DisplayString
  ctrl3ChName DisplayString
  ctrl3ChAvail Gauge32
  ctrl3ChVoltsA Gauge32
  ctrl3ChVoltPeakA Gauge32
  ctrl3ChDeciAmpsA Gauge32
  ctrl3ChDeciAmpsPeakA Gauge32
  ctrl3ChRealPowerA Gauge32
  ctrl3ChApparentPowerA Gauge32
  ctrl3ChPowerFactorA INTEGER
  ctrl3ChVoltsB Gauge32
  ctrl3ChVoltPeakB Gauge32
  ctrl3ChDeciAmpsB Gauge32
  ctrl3ChDeciAmpsPeakB Gauge32
  ctrl3ChRealPowerB Gauge32
  ctrl3ChApparentPowerB Gauge32
  ctrl3ChPowerFactorB INTEGER
  ctrl3ChVoltsC Gauge32
  ctrl3ChVoltPeakC Gauge32
  ctrl3ChDeciAmpsC Gauge32
  ctrl3ChDeciAmpsPeakC Gauge32
  ctrl3ChRealPowerC Gauge32
  ctrl3ChApparentPowerC Gauge32
  ctrl3ChPowerFactorC INTEGER

CtrlGrpAmpsEntry  
SEQUENCE    
  ctrlGrpAmpsIndex INTEGER
  ctrlGrpAmpsSerial DisplayString
  ctrlGrpAmpsName DisplayString
  ctrlGrpAmpsAvail Gauge32
  ctrlGrpAmpsA Gauge32
  ctrlGrpAmpsB Gauge32
  ctrlGrpAmpsC Gauge32
  ctrlGrpAmpsD Gauge32
  ctrlGrpAmpsE Gauge32
  ctrlGrpAmpsF Gauge32
  ctrlGrpAmpsG Gauge32
  ctrlGrpAmpsH Gauge32
  ctrlGrpAmpsAVolts Gauge32
  ctrlGrpAmpsBVolts Gauge32
  ctrlGrpAmpsCVolts Gauge32
  ctrlGrpAmpsDVolts Gauge32
  ctrlGrpAmpsEVolts Gauge32
  ctrlGrpAmpsFVolts Gauge32
  ctrlGrpAmpsGVolts Gauge32
  ctrlGrpAmpsHVolts Gauge32
  ctrlGrpAmpsI Gauge32
  ctrlGrpAmpsJ Gauge32
  ctrlGrpAmpsK Gauge32
  ctrlGrpAmpsL Gauge32
  ctrlGrpAmpsM Gauge32
  ctrlGrpAmpsN Gauge32
  ctrlGrpAmpsO Gauge32
  ctrlGrpAmpsP Gauge32
  ctrlGrpAmpsIVolts Gauge32
  ctrlGrpAmpsJVolts Gauge32
  ctrlGrpAmpsKVolts Gauge32
  ctrlGrpAmpsLVolts Gauge32
  ctrlGrpAmpsMVolts Gauge32
  ctrlGrpAmpsNVolts Gauge32
  ctrlGrpAmpsOVolts Gauge32
  ctrlGrpAmpsPVolts Gauge32

CtrlOutletEntry  
SEQUENCE    
  ctrlOutletIndex INTEGER
  ctrlOutletName DisplayString
  ctrlOutletStatus Gauge32
  ctrlOutletFeedback Gauge32
  ctrlOutletPending Gauge32
  ctrlOutletDeciAmps Gauge32
  ctrlOutletGroup DisplayString
  ctrlOutletUpDelay Gauge32
  ctrlOutletDwnDelay Gauge32
  ctrlOutletRbtDuration Gauge32
  ctrlOutletURL DisplayString
  ctrlOutletPOAAction Gauge32
  ctrlOutletPOADelay Gauge32
  ctrlOutletkWattHrs Gauge32
  ctrlOutletPower Gauge32
  ctrlOutletRbtDelay Gauge32
  ctrlOutletStatusTime Gauge32

DewPointSensorEntry  
SEQUENCE    
  dewPointSensorIndex INTEGER
  dewPointSensorSerial DisplayString
  dewPointSensorName DisplayString
  dewPointSensorAvail Gauge32
  dewPointSensorTempC INTEGER
  dewPointSensorTempF INTEGER
  dewPointSensorHumidity INTEGER
  dewPointSensorDewPointC INTEGER
  dewPointSensorDewPointF INTEGER

DigitalSensorEntry  
SEQUENCE    
  digitalSensorIndex INTEGER
  digitalSensorSerial DisplayString
  digitalSensorName DisplayString
  digitalSensorAvail Gauge32
  digitalSensorDigital INTEGER

DstsEntry  
SEQUENCE    
  dstsIndex INTEGER
  dstsSerial DisplayString
  dstsName DisplayString
  dstsAvail Gauge32
  dstsVoltsA Gauge32
  dstsDeciAmpsA Gauge32
  dstsVoltsB Gauge32
  dstsDeciAmpsB Gauge32
  dstsSourceAActive Gauge32
  dstsSourceBActive Gauge32
  dstsPowerStatusA Gauge32
  dstsPowerStatusB Gauge32
  dstsSourceATempC INTEGER
  dstsSourceBTempC INTEGER

CpmSensorEntry  
SEQUENCE    
  cpmSensorIndex INTEGER
  cpmSensorSerial DisplayString
  cpmSensorName DisplayString
  cpmSensorAvail Gauge32
  cpmSensorStatus INTEGER

SmokeAlarmEntry  
SEQUENCE    
  smokeAlarmIndex INTEGER
  smokeAlarmSerial DisplayString
  smokeAlarmName DisplayString
  smokeAlarmAvail Gauge32
  smokeAlarmStatus INTEGER

Neg48VdcSensorEntry  
SEQUENCE    
  neg48VdcSensorIndex INTEGER
  neg48VdcSensorSerial DisplayString
  neg48VdcSensorName DisplayString
  neg48VdcSensorAvail Gauge32
  neg48VdcSensorVoltage INTEGER

Pos30VdcSensorEntry  
SEQUENCE    
  pos30VdcSensorIndex INTEGER
  pos30VdcSensorSerial DisplayString
  pos30VdcSensorName DisplayString
  pos30VdcSensorAvail Gauge32
  pos30VdcSensorVoltage INTEGER

AnalogSensorEntry  
SEQUENCE    
  analogSensorIndex INTEGER
  analogSensorSerial DisplayString
  analogSensorName DisplayString
  analogSensorAvail Gauge32
  analogSensorAnalog INTEGER

Ctrl3ChIECEntry  
SEQUENCE    
  ctrl3ChIECIndex INTEGER
  ctrl3ChIECSerial DisplayString
  ctrl3ChIECName DisplayString
  ctrl3ChIECAvail Gauge32
  ctrl3ChIECkWattHrsA Gauge32
  ctrl3ChIECVoltsA Gauge32
  ctrl3ChIECVoltPeakA Gauge32
  ctrl3ChIECDeciAmpsA Gauge32
  ctrl3ChIECDeciAmpsPeakA Gauge32
  ctrl3ChIECRealPowerA Gauge32
  ctrl3ChIECApparentPowerA Gauge32
  ctrl3ChIECPowerFactorA INTEGER
  ctrl3ChIECkWattHrsB Gauge32
  ctrl3ChIECVoltsB Gauge32
  ctrl3ChIECVoltPeakB Gauge32
  ctrl3ChIECDeciAmpsB Gauge32
  ctrl3ChIECDeciAmpsPeakB Gauge32
  ctrl3ChIECRealPowerB Gauge32
  ctrl3ChIECApparentPowerB Gauge32
  ctrl3ChIECPowerFactorB INTEGER
  ctrl3ChIECkWattHrsC Gauge32
  ctrl3ChIECVoltsC Gauge32
  ctrl3ChIECVoltPeakC Gauge32
  ctrl3ChIECDeciAmpsC Gauge32
  ctrl3ChIECDeciAmpsPeakC Gauge32
  ctrl3ChIECRealPowerC Gauge32
  ctrl3ChIECApparentPowerC Gauge32
  ctrl3ChIECPowerFactorC INTEGER
  ctrl3ChIECkWattHrsTotal Gauge32
  ctrl3ChIECRealPowerTotal Gauge32

ClimateRelayEntry  
SEQUENCE    
  climateRelayIndex INTEGER
  climateRelaySerial DisplayString
  climateRelayName DisplayString
  climateRelayAvail Gauge32
  climateRelayTempC INTEGER
  climateRelayTempF INTEGER
  climateRelayIO1 INTEGER
  climateRelayIO2 INTEGER
  climateRelayIO3 INTEGER
  climateRelayIO4 INTEGER
  climateRelayIO5 INTEGER
  climateRelayIO6 INTEGER

CtrlRelayEntry  
SEQUENCE    
  ctrlRelayIndex INTEGER
  ctrlRelayName DisplayString
  ctrlRelayState Gauge32
  ctrlRelayLatchingMode Gauge32
  ctrlRelayOverride Gauge32
  ctrlRelayAcknowledge Gauge32

AirSpeedSwitchSensorEntry  
SEQUENCE    
  airSpeedSwitchSensorIndex INTEGER
  airSpeedSwitchSensorSerial DisplayString
  airSpeedSwitchSensorName DisplayString
  airSpeedSwitchSensorAvail Gauge32
  airSpeedSwitchSensorAirSpeed INTEGER

PowerDMEntry  
SEQUENCE    
  powerDMIndex INTEGER
  powerDMSerial DisplayString
  powerDMName DisplayString
  powerDMAvail Gauge32
  powerDMUnitInfoTitle DisplayString
  powerDMUnitInfoVersion DisplayString
  powerDMUnitInfoMainCount INTEGER
  powerDMUnitInfoAuxCount INTEGER
  powerDMChannelName1 DisplayString
  powerDMChannelName2 DisplayString
  powerDMChannelName3 DisplayString
  powerDMChannelName4 DisplayString
  powerDMChannelName5 DisplayString
  powerDMChannelName6 DisplayString
  powerDMChannelName7 DisplayString
  powerDMChannelName8 DisplayString
  powerDMChannelName9 DisplayString
  powerDMChannelName10 DisplayString
  powerDMChannelName11 DisplayString
  powerDMChannelName12 DisplayString
  powerDMChannelName13 DisplayString
  powerDMChannelName14 DisplayString
  powerDMChannelName15 DisplayString
  powerDMChannelName16 DisplayString
  powerDMChannelName17 DisplayString
  powerDMChannelName18 DisplayString
  powerDMChannelName19 DisplayString
  powerDMChannelName20 DisplayString
  powerDMChannelName21 DisplayString
  powerDMChannelName22 DisplayString
  powerDMChannelName23 DisplayString
  powerDMChannelName24 DisplayString
  powerDMChannelName25 DisplayString
  powerDMChannelName26 DisplayString
  powerDMChannelName27 DisplayString
  powerDMChannelName28 DisplayString
  powerDMChannelName29 DisplayString
  powerDMChannelName30 DisplayString
  powerDMChannelName31 DisplayString
  powerDMChannelName32 DisplayString
  powerDMChannelName33 DisplayString
  powerDMChannelName34 DisplayString
  powerDMChannelName35 DisplayString
  powerDMChannelName36 DisplayString
  powerDMChannelName37 DisplayString
  powerDMChannelName38 DisplayString
  powerDMChannelName39 DisplayString
  powerDMChannelName40 DisplayString
  powerDMChannelName41 DisplayString
  powerDMChannelName42 DisplayString
  powerDMChannelName43 DisplayString
  powerDMChannelName44 DisplayString
  powerDMChannelName45 DisplayString
  powerDMChannelName46 DisplayString
  powerDMChannelName47 DisplayString
  powerDMChannelName48 DisplayString
  powerDMChannelFriendly1 DisplayString
  powerDMChannelFriendly2 DisplayString
  powerDMChannelFriendly3 DisplayString
  powerDMChannelFriendly4 DisplayString
  powerDMChannelFriendly5 DisplayString
  powerDMChannelFriendly6 DisplayString
  powerDMChannelFriendly7 DisplayString
  powerDMChannelFriendly8 DisplayString
  powerDMChannelFriendly9 DisplayString
  powerDMChannelFriendly10 DisplayString
  powerDMChannelFriendly11 DisplayString
  powerDMChannelFriendly12 DisplayString
  powerDMChannelFriendly13 DisplayString
  powerDMChannelFriendly14 DisplayString
  powerDMChannelFriendly15 DisplayString
  powerDMChannelFriendly16 DisplayString
  powerDMChannelFriendly17 DisplayString
  powerDMChannelFriendly18 DisplayString
  powerDMChannelFriendly19 DisplayString
  powerDMChannelFriendly20 DisplayString
  powerDMChannelFriendly21 DisplayString
  powerDMChannelFriendly22 DisplayString
  powerDMChannelFriendly23 DisplayString
  powerDMChannelFriendly24 DisplayString
  powerDMChannelFriendly25 DisplayString
  powerDMChannelFriendly26 DisplayString
  powerDMChannelFriendly27 DisplayString
  powerDMChannelFriendly28 DisplayString
  powerDMChannelFriendly29 DisplayString
  powerDMChannelFriendly30 DisplayString
  powerDMChannelFriendly31 DisplayString
  powerDMChannelFriendly32 DisplayString
  powerDMChannelFriendly33 DisplayString
  powerDMChannelFriendly34 DisplayString
  powerDMChannelFriendly35 DisplayString
  powerDMChannelFriendly36 DisplayString
  powerDMChannelFriendly37 DisplayString
  powerDMChannelFriendly38 DisplayString
  powerDMChannelFriendly39 DisplayString
  powerDMChannelFriendly40 DisplayString
  powerDMChannelFriendly41 DisplayString
  powerDMChannelFriendly42 DisplayString
  powerDMChannelFriendly43 DisplayString
  powerDMChannelFriendly44 DisplayString
  powerDMChannelFriendly45 DisplayString
  powerDMChannelFriendly46 DisplayString
  powerDMChannelFriendly47 DisplayString
  powerDMChannelFriendly48 DisplayString
  powerDMChannelGroup1 DisplayString
  powerDMChannelGroup2 DisplayString
  powerDMChannelGroup3 DisplayString
  powerDMChannelGroup4 DisplayString
  powerDMChannelGroup5 DisplayString
  powerDMChannelGroup6 DisplayString
  powerDMChannelGroup7 DisplayString
  powerDMChannelGroup8 DisplayString
  powerDMChannelGroup9 DisplayString
  powerDMChannelGroup10 DisplayString
  powerDMChannelGroup11 DisplayString
  powerDMChannelGroup12 DisplayString
  powerDMChannelGroup13 DisplayString
  powerDMChannelGroup14 DisplayString
  powerDMChannelGroup15 DisplayString
  powerDMChannelGroup16 DisplayString
  powerDMChannelGroup17 DisplayString
  powerDMChannelGroup18 DisplayString
  powerDMChannelGroup19 DisplayString
  powerDMChannelGroup20 DisplayString
  powerDMChannelGroup21 DisplayString
  powerDMChannelGroup22 DisplayString
  powerDMChannelGroup23 DisplayString
  powerDMChannelGroup24 DisplayString
  powerDMChannelGroup25 DisplayString
  powerDMChannelGroup26 DisplayString
  powerDMChannelGroup27 DisplayString
  powerDMChannelGroup28 DisplayString
  powerDMChannelGroup29 DisplayString
  powerDMChannelGroup30 DisplayString
  powerDMChannelGroup31 DisplayString
  powerDMChannelGroup32 DisplayString
  powerDMChannelGroup33 DisplayString
  powerDMChannelGroup34 DisplayString
  powerDMChannelGroup35 DisplayString
  powerDMChannelGroup36 DisplayString
  powerDMChannelGroup37 DisplayString
  powerDMChannelGroup38 DisplayString
  powerDMChannelGroup39 DisplayString
  powerDMChannelGroup40 DisplayString
  powerDMChannelGroup41 DisplayString
  powerDMChannelGroup42 DisplayString
  powerDMChannelGroup43 DisplayString
  powerDMChannelGroup44 DisplayString
  powerDMChannelGroup45 DisplayString
  powerDMChannelGroup46 DisplayString
  powerDMChannelGroup47 DisplayString
  powerDMChannelGroup48 DisplayString
  powerDMDeciAmps1 INTEGER
  powerDMDeciAmps2 INTEGER
  powerDMDeciAmps3 INTEGER
  powerDMDeciAmps4 INTEGER
  powerDMDeciAmps5 INTEGER
  powerDMDeciAmps6 INTEGER
  powerDMDeciAmps7 INTEGER
  powerDMDeciAmps8 INTEGER
  powerDMDeciAmps9 INTEGER
  powerDMDeciAmps10 INTEGER
  powerDMDeciAmps11 INTEGER
  powerDMDeciAmps12 INTEGER
  powerDMDeciAmps13 INTEGER
  powerDMDeciAmps14 INTEGER
  powerDMDeciAmps15 INTEGER
  powerDMDeciAmps16 INTEGER
  powerDMDeciAmps17 INTEGER
  powerDMDeciAmps18 INTEGER
  powerDMDeciAmps19 INTEGER
  powerDMDeciAmps20 INTEGER
  powerDMDeciAmps21 INTEGER
  powerDMDeciAmps22 INTEGER
  powerDMDeciAmps23 INTEGER
  powerDMDeciAmps24 INTEGER
  powerDMDeciAmps25 INTEGER
  powerDMDeciAmps26 INTEGER
  powerDMDeciAmps27 INTEGER
  powerDMDeciAmps28 INTEGER
  powerDMDeciAmps29 INTEGER
  powerDMDeciAmps30 INTEGER
  powerDMDeciAmps31 INTEGER
  powerDMDeciAmps32 INTEGER
  powerDMDeciAmps33 INTEGER
  powerDMDeciAmps34 INTEGER
  powerDMDeciAmps35 INTEGER
  powerDMDeciAmps36 INTEGER
  powerDMDeciAmps37 INTEGER
  powerDMDeciAmps38 INTEGER
  powerDMDeciAmps39 INTEGER
  powerDMDeciAmps40 INTEGER
  powerDMDeciAmps41 INTEGER
  powerDMDeciAmps42 INTEGER
  powerDMDeciAmps43 INTEGER
  powerDMDeciAmps44 INTEGER
  powerDMDeciAmps45 INTEGER
  powerDMDeciAmps46 INTEGER
  powerDMDeciAmps47 INTEGER
  powerDMDeciAmps48 INTEGER

IoExpanderEntry  
SEQUENCE    
  ioExpanderIndex INTEGER
  ioExpanderSerial DisplayString
  ioExpanderName DisplayString
  ioExpanderAvail Gauge32
  ioExpanderFriendlyName1 DisplayString
  ioExpanderFriendlyName2 DisplayString
  ioExpanderFriendlyName3 DisplayString
  ioExpanderFriendlyName4 DisplayString
  ioExpanderFriendlyName5 DisplayString
  ioExpanderFriendlyName6 DisplayString
  ioExpanderFriendlyName7 DisplayString
  ioExpanderFriendlyName8 DisplayString
  ioExpanderFriendlyName9 DisplayString
  ioExpanderFriendlyName10 DisplayString
  ioExpanderFriendlyName11 DisplayString
  ioExpanderFriendlyName12 DisplayString
  ioExpanderFriendlyName13 DisplayString
  ioExpanderFriendlyName14 DisplayString
  ioExpanderFriendlyName15 DisplayString
  ioExpanderFriendlyName16 DisplayString
  ioExpanderFriendlyName17 DisplayString
  ioExpanderFriendlyName18 DisplayString
  ioExpanderFriendlyName19 DisplayString
  ioExpanderFriendlyName20 DisplayString
  ioExpanderFriendlyName21 DisplayString
  ioExpanderFriendlyName22 DisplayString
  ioExpanderFriendlyName23 DisplayString
  ioExpanderFriendlyName24 DisplayString
  ioExpanderFriendlyName25 DisplayString
  ioExpanderFriendlyName26 DisplayString
  ioExpanderFriendlyName27 DisplayString
  ioExpanderFriendlyName28 DisplayString
  ioExpanderFriendlyName29 DisplayString
  ioExpanderFriendlyName30 DisplayString
  ioExpanderFriendlyName31 DisplayString
  ioExpanderFriendlyName32 DisplayString
  ioExpanderIO1 INTEGER
  ioExpanderIO2 INTEGER
  ioExpanderIO3 INTEGER
  ioExpanderIO4 INTEGER
  ioExpanderIO5 INTEGER
  ioExpanderIO6 INTEGER
  ioExpanderIO7 INTEGER
  ioExpanderIO8 INTEGER
  ioExpanderIO9 INTEGER
  ioExpanderIO10 INTEGER
  ioExpanderIO11 INTEGER
  ioExpanderIO12 INTEGER
  ioExpanderIO13 INTEGER
  ioExpanderIO14 INTEGER
  ioExpanderIO15 INTEGER
  ioExpanderIO16 INTEGER
  ioExpanderIO17 INTEGER
  ioExpanderIO18 INTEGER
  ioExpanderIO19 INTEGER
  ioExpanderIO20 INTEGER
  ioExpanderIO21 INTEGER
  ioExpanderIO22 INTEGER
  ioExpanderIO23 INTEGER
  ioExpanderIO24 INTEGER
  ioExpanderIO25 INTEGER
  ioExpanderIO26 INTEGER
  ioExpanderIO27 INTEGER
  ioExpanderIO28 INTEGER
  ioExpanderIO29 INTEGER
  ioExpanderIO30 INTEGER
  ioExpanderIO31 INTEGER
  ioExpanderIO32 INTEGER
  ioExpanderRelayName1 DisplayString
  ioExpanderRelayState1 Gauge32
  ioExpanderRelayLatchingMode1 Gauge32
  ioExpanderRelayOverride1 Gauge32
  ioExpanderRelayAcknowledge1 Gauge32
  ioExpanderRelayName2 DisplayString
  ioExpanderRelayState2 Gauge32
  ioExpanderRelayLatchingMode2 Gauge32
  ioExpanderRelayOverride2 Gauge32
  ioExpanderRelayAcknowledge2 Gauge32
  ioExpanderRelayName3 DisplayString
  ioExpanderRelayState3 Gauge32
  ioExpanderRelayLatchingMode3 Gauge32
  ioExpanderRelayOverride3 Gauge32
  ioExpanderRelayAcknowledge3 Gauge32

T3hdSensorEntry  
SEQUENCE    
  t3hdSensorIndex INTEGER
  t3hdSensorSerial DisplayString
  t3hdSensorName DisplayString
  t3hdSensorAvail Gauge32
  t3hdSensorIntName DisplayString
  t3hdSensorIntTempC INTEGER
  t3hdSensorIntTempF INTEGER
  t3hdSensorIntHumidity INTEGER
  t3hdSensorIntDewPointC INTEGER
  t3hdSensorIntDewPointF INTEGER
  t3hdSensorExt1Avail Gauge32
  t3hdSensorExt1Name DisplayString
  t3hdSensorExt1TempC INTEGER
  t3hdSensorExt1TempF INTEGER
  t3hdSensorExt2Avail Gauge32
  t3hdSensorExt2Name DisplayString
  t3hdSensorExt2TempC INTEGER
  t3hdSensorExt2TempF INTEGER

ThdSensorEntry  
SEQUENCE    
  thdSensorIndex INTEGER
  thdSensorSerial DisplayString
  thdSensorName DisplayString
  thdSensorAvail Gauge32
  thdSensorTempC INTEGER
  thdSensorTempF INTEGER
  thdSensorHumidity INTEGER
  thdSensorDewPointC INTEGER
  thdSensorDewPointF INTEGER

Pos60VdcSensorEntry  
SEQUENCE    
  pos60VdcSensorIndex INTEGER
  pos60VdcSensorSerial DisplayString
  pos60VdcSensorName DisplayString
  pos60VdcSensorAvail Gauge32
  pos60VdcSensorVoltage INTEGER

Ctrl2CirTotEntry  
SEQUENCE    
  ctrl2CirTotIndex INTEGER
  ctrl2CirTotSerial DisplayString
  ctrl2CirTotName DisplayString
  ctrl2CirTotAvail Gauge32
  ctrl2CirTotkWattHrsTot Gauge32
  ctrl2CirTotVoltsTot Gauge32
  ctrl2CirTotVoltPeakTot Gauge32
  ctrl2CirTotDeciAmpsTot Gauge32
  ctrl2CirTotDeciAmpsPeakTot Gauge32
  ctrl2CirTotRealPowerTot Gauge32
  ctrl2CirTotApparentPowerTot Gauge32
  ctrl2CirTotPowerFactorTot INTEGER
  ctrl2CirTotkWattHrsA Gauge32
  ctrl2CirTotVoltsA Gauge32
  ctrl2CirTotVoltPeakA Gauge32
  ctrl2CirTotDeciAmpsA Gauge32
  ctrl2CirTotDeciAmpsPeakA Gauge32
  ctrl2CirTotRealPowerA Gauge32
  ctrl2CirTotApparentPowerA Gauge32
  ctrl2CirTotPowerFactorA INTEGER
  ctrl2CirTotkWattHrsB Gauge32
  ctrl2CirTotVoltsB Gauge32
  ctrl2CirTotVoltPeakB Gauge32
  ctrl2CirTotDeciAmpsB Gauge32
  ctrl2CirTotDeciAmpsPeakB Gauge32
  ctrl2CirTotRealPowerB Gauge32
  ctrl2CirTotApparentPowerB Gauge32
  ctrl2CirTotPowerFactorB INTEGER

Sc10Entry  
SEQUENCE    
  sc10Index INTEGER
  sc10Serial DisplayString
  sc10Name DisplayString
  sc10Avail Gauge32
  sc10ControlMode INTEGER
  sc10SetpointC INTEGER
  sc10SetpointF INTEGER
  sc10TempC INTEGER
  sc10TempF INTEGER
  sc10Capacity INTEGER

AlarmCfgEntry  
SEQUENCE    
  alarmCfgIndex INTEGER
  alarmCfgReadingID OBJECT IDENTIFIER
  alarmCfgThreshold Integer32
  alarmCfgTripSelect INTEGER

Defined Values

itwatchdogs 1.3.6.1.4.1.17373
The MIB for I.T. Watchdogs Products
MODULE-IDENTITY    

itwatchdogs 1.3.6.1.4.1.17373
OBJECT IDENTIFIER    

owl 1.3.6.1.4.1.17373.3
OBJECT IDENTIFIER    

deviceInfo 1.3.6.1.4.1.17373.3.1
OBJECT IDENTIFIER    

productTitle 1.3.6.1.4.1.17373.3.1.1
Product name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

productVersion 1.3.6.1.4.1.17373.3.1.2
Product version
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

productFriendlyName 1.3.6.1.4.1.17373.3.1.3
User-assigned name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

productMacAddress 1.3.6.1.4.1.17373.3.1.4
Product's unique MAC address
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

productUrl 1.3.6.1.4.1.17373.3.1.5
Product's main URL access point
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

alarmTripType 1.3.6.1.4.1.17373.3.1.6
Type of alarm trip. 0 = None, 1 = Low, 2 = High, 3 = Unplugged
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(0), low(1), high(2), unplugged(3)  

productHardware 1.3.6.1.4.1.17373.3.1.7
Product's hardware type
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

temperaturePrecision 1.3.6.1.4.1.17373.3.1.9
Temperature Precision: 0 = degree: whole degree (value X 1) 1 = deci-degree: tenths of a degree (value X 10) ex. 550 = 55.0 degrees
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER degree(0), deciDegree(1)  

alarmTrigger 1.3.6.1.4.1.17373.3.1.11
Used in a trap var-bind to indicate what triggered the alarm. The alarmTrigger will remain consistent for both trip and clear traps. Possible values include: 'Low' = Low-trip trigger 'High' = High-trip trigger 'Unplugged' = Unplugged device trigger
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

alarmInstance 1.3.6.1.4.1.17373.3.1.12
Provides the row index (instance number) for the alarm that generated a trap. This value is only available when included in the var-binds of an associated trap.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  INTEGER 1..200  

sensorCountsBase 1.3.6.1.4.1.17373.3.1.8
OBJECT IDENTIFIER    

sensorCounts 1.3.6.1.4.1.17373.3.1.8.1
OBJECT IDENTIFIER    

climateCount 1.3.6.1.4.1.17373.3.1.8.1.2
Number of climate monitors currently plugged in
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..16  

powerMonitorCount 1.3.6.1.4.1.17373.3.1.8.1.3
Number of power monitors currently plugged in
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..16  

tempSensorCount 1.3.6.1.4.1.17373.3.1.8.1.4
Number of temperature sensors currently plugged in
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..16  

airflowSensorCount 1.3.6.1.4.1.17373.3.1.8.1.5
Number of airflow sensors currently plugged in
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..16  

ctrl3ChDELTACount 1.3.6.1.4.1.17373.3.1.8.1.6
Number of DELTA 3 channel controllers currently plugged in
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..16  

doorSensorCount 1.3.6.1.4.1.17373.3.1.8.1.7
Number of door sensors currently plugged in
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..16  

waterSensorCount 1.3.6.1.4.1.17373.3.1.8.1.8
Number of water sensors currently plugged in
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..16  

currentSensorCount 1.3.6.1.4.1.17373.3.1.8.1.9
Number of current sensors currently plugged in
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..16  

millivoltSensorCount 1.3.6.1.4.1.17373.3.1.8.1.10
Number of millivolt sensors currently plugged in
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..16  

power3ChSensorCount 1.3.6.1.4.1.17373.3.1.8.1.11
Number of 3 channel power monitors currently plugged in
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..16  

outletCount 1.3.6.1.4.1.17373.3.1.8.1.12
Number of outlets currently plugged in
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..16  

vsfcCount 1.3.6.1.4.1.17373.3.1.8.1.13
Number of fan controller monitors currently plugged in
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..16  

ctrl3ChCount 1.3.6.1.4.1.17373.3.1.8.1.14
Number of 3 channel controllers currently plugged in
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..16  

ctrlGrpAmpsCount 1.3.6.1.4.1.17373.3.1.8.1.15
Number of amperage controllers currently plugged in
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..16  

ctrlOutletCount 1.3.6.1.4.1.17373.3.1.8.1.16
Number of monitored or switched outlets
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..16  

dewpointSensorCount 1.3.6.1.4.1.17373.3.1.8.1.17
Number of dewpoint sensors currently plugged in
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..16  

digitalSensorCount 1.3.6.1.4.1.17373.3.1.8.1.18
Number of digital sensors currently plugged in
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..16  

dstsSensorCount 1.3.6.1.4.1.17373.3.1.8.1.19
Number of DSTS controllers currently plugged in
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..16  

cpmSensorCount 1.3.6.1.4.1.17373.3.1.8.1.20
Number of city power sensors currently plugged in
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..16  

smokeAlarmSensorCount 1.3.6.1.4.1.17373.3.1.8.1.21
Number of smoke alarm sensors currently plugged in
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..16  

neg48VdcSensorCount 1.3.6.1.4.1.17373.3.1.8.1.22
Number of -48Vdc sensors currently plugged in
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..16  

pos30VdcSensorCount 1.3.6.1.4.1.17373.3.1.8.1.23
Number of 30Vdc sensors currently plugged in
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..16  

analogSensorCount 1.3.6.1.4.1.17373.3.1.8.1.24
Number of remote analog inputs currently plugged in
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..16  

ctrl3ChIECCount 1.3.6.1.4.1.17373.3.1.8.1.25
Number of IEC 3 channel controllers currently plugged in
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..16  

climateRelayCount 1.3.6.1.4.1.17373.3.1.8.1.26
Number of climate relay monitors currently plugged in
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..16  

ctrlRelayCount 1.3.6.1.4.1.17373.3.1.8.1.27
Number of relay controllers currently plugged in
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..16  

airSpeedSwitchSensorCount 1.3.6.1.4.1.17373.3.1.8.1.28
Number of air speed switch sensors currently plugged in
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..16  

powerDMCount 1.3.6.1.4.1.17373.3.1.8.1.29
Number of DM48 current sensors currently plugged in
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..16  

ioExpanderCount 1.3.6.1.4.1.17373.3.1.8.1.30
Number of IO expander devices currently plugged in
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..16  

t3hdSensorCount 1.3.6.1.4.1.17373.3.1.8.1.31
Number of T3HD sensors currently plugged in
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..16  

thdSensorCount 1.3.6.1.4.1.17373.3.1.8.1.32
Number of THD sensors currently plugged in
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..16  

pos60VdcSensorCount 1.3.6.1.4.1.17373.3.1.8.1.33
Number of 60Vdc sensors currently plugged in
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..16  

ctrl2CirTotCount 1.3.6.1.4.1.17373.3.1.8.1.34
Number of IEC 3 channel controllers currently plugged in
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..16  

sc10Count 1.3.6.1.4.1.17373.3.1.8.1.35
Number of fan controller monitors currently plugged in
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..16  

climateTable 1.3.6.1.4.1.17373.3.2
Climate sensors (internal sensors for climate units)
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ClimateEntry

powMonTable 1.3.6.1.4.1.17373.3.3
A table of Power Monitors
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PowMonEntry

tempSensorTable 1.3.6.1.4.1.17373.3.4
A table of temperature sensors
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TempSensorEntry

airFlowSensorTable 1.3.6.1.4.1.17373.3.5
A table of airflow sensors
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AirFlowSensorEntry

ctrl3ChDELTATable 1.3.6.1.4.1.17373.3.6
A table of a 3 phase outlet control (DELTA)
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ctrl3ChDELTAEntry

doorSensorTable 1.3.6.1.4.1.17373.3.7
A table of door sensors
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DoorSensorEntry

waterSensorTable 1.3.6.1.4.1.17373.3.8
A table of water sensors
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    WaterSensorEntry

currentMonitorTable 1.3.6.1.4.1.17373.3.9
A table of current monitors
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CurrentMonitorEntry

millivoltMonitorTable 1.3.6.1.4.1.17373.3.10
A table of millivolt monitors
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MillivoltMonitorEntry

pow3ChTable 1.3.6.1.4.1.17373.3.11
A table of Power Monitor 3 Channel
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Pow3ChEntry

outletTable 1.3.6.1.4.1.17373.3.12
A table of outlets
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OutletEntry

vsfcTable 1.3.6.1.4.1.17373.3.13
VSFC sensors (internal sensors for VSFC units)
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    VsfcEntry

ctrl3ChTable 1.3.6.1.4.1.17373.3.14
A table of a 3 phase outlet control
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ctrl3ChEntry

ctrlGrpAmpsTable 1.3.6.1.4.1.17373.3.15
A table of Control Group Amp readings
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CtrlGrpAmpsEntry

ctrlOutletTable 1.3.6.1.4.1.17373.3.16
A table of outlet information
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CtrlOutletEntry

dewPointSensorTable 1.3.6.1.4.1.17373.3.17
A table of dew point sensors
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DewPointSensorEntry

digitalSensorTable 1.3.6.1.4.1.17373.3.18
A table of digital sensors
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DigitalSensorEntry

dstsTable 1.3.6.1.4.1.17373.3.19
Digital Static Transfer Switch status
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DstsEntry

cpmSensorTable 1.3.6.1.4.1.17373.3.20
A table of city power sensors
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CpmSensorEntry

smokeAlarmTable 1.3.6.1.4.1.17373.3.21
A table of smoke alarm sensors
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SmokeAlarmEntry

neg48VdcSensorTable 1.3.6.1.4.1.17373.3.22
A table of -48Vdc sensors
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Neg48VdcSensorEntry

pos30VdcSensorTable 1.3.6.1.4.1.17373.3.23
A table of 30Vdc sensors
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Pos30VdcSensorEntry

analogSensorTable 1.3.6.1.4.1.17373.3.24
A table of analog sensors
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AnalogSensorEntry

ctrl3ChIECTable 1.3.6.1.4.1.17373.3.25
A table of a 3 phase outlet control (IEC)
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ctrl3ChIECEntry

climateRelayTable 1.3.6.1.4.1.17373.3.26
Climate Relay sensors (internal sensors for climate relay units)
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ClimateRelayEntry

ctrlRelayTable 1.3.6.1.4.1.17373.3.27
A table of relay information
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CtrlRelayEntry

airSpeedSwitchSensorTable 1.3.6.1.4.1.17373.3.28
A table of air speed switch sensors
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AirSpeedSwitchSensorEntry

powerDMTable 1.3.6.1.4.1.17373.3.29
A table of DM48 current monitors
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PowerDMEntry

ioExpanderTable 1.3.6.1.4.1.17373.3.30
IO Expander device with relay capability
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    IoExpanderEntry

t3hdSensorTable 1.3.6.1.4.1.17373.3.31
A table of T3HD sensors
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    T3hdSensorEntry

thdSensorTable 1.3.6.1.4.1.17373.3.32
A table of THD sensors
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ThdSensorEntry

pos60VdcSensorTable 1.3.6.1.4.1.17373.3.33
A table of 60Vdc sensors
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Pos60VdcSensorEntry

ctrl2CirTotTable 1.3.6.1.4.1.17373.3.34
A table of a 3 phase outlet control (IEC)
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ctrl2CirTotEntry

sc10Table 1.3.6.1.4.1.17373.3.35
SC10 sensors (internal measurements for SC10 units)
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Sc10Entry

climateEntry 1.3.6.1.4.1.17373.3.2.1
Entry in the climate table: each entry contains an index (climateIndex) and other details
Status: current Access: not-accessible
OBJECT-TYPE    
  ClimateEntry  

climateIndex 1.3.6.1.4.1.17373.3.2.1.1
Table entry index value
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..1  

climateSerial 1.3.6.1.4.1.17373.3.2.1.2
Serial Number
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

climateName 1.3.6.1.4.1.17373.3.2.1.3
Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

climateAvail 1.3.6.1.4.1.17373.3.2.1.4
Is device currently plugged in?
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

climateTempC 1.3.6.1.4.1.17373.3.2.1.5
Current reading for Temperature (C)
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER -50..100  

climateTempF 1.3.6.1.4.1.17373.3.2.1.6
Current reading for Temperature (F)
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER -58..212  

climateHumidity 1.3.6.1.4.1.17373.3.2.1.7
Current reading for Humidity
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

climateLight 1.3.6.1.4.1.17373.3.2.1.8
Current reading for Ambient Light
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

climateAirflow 1.3.6.1.4.1.17373.3.2.1.9
Current reading for Airflow
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

climateSound 1.3.6.1.4.1.17373.3.2.1.10
Current reading for Sound
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

climateIO1 1.3.6.1.4.1.17373.3.2.1.11
Current reading for Analog Input 1
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

climateIO2 1.3.6.1.4.1.17373.3.2.1.12
Current reading for Analog Input 2
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

climateIO3 1.3.6.1.4.1.17373.3.2.1.13
Current reading for Analog Input 3
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

climateDewPointC 1.3.6.1.4.1.17373.3.2.1.14
Current reading for Dew Point (C)
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER -50..100  

climateDewPointF 1.3.6.1.4.1.17373.3.2.1.15
Current reading for Dew Point (F)
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER -58..212  

powMonEntry 1.3.6.1.4.1.17373.3.3.1
Entry in the power monitor table: each entry contains an index (powMonIndex) and other power monitoring details
Status: current Access: not-accessible
OBJECT-TYPE    
  PowMonEntry  

powMonIndex 1.3.6.1.4.1.17373.3.3.1.1
Table entry index value
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..100  

powMonSerial 1.3.6.1.4.1.17373.3.3.1.2
Serial Number
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powMonName 1.3.6.1.4.1.17373.3.3.1.3
Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powMonAvail 1.3.6.1.4.1.17373.3.3.1.4
Is device currently plugged in?
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

powMonkWattHrs 1.3.6.1.4.1.17373.3.3.1.5
Current reading for kWatt-Hours
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

powMonVolts 1.3.6.1.4.1.17373.3.3.1.6
Current reading for Volts
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

powMonVoltMax 1.3.6.1.4.1.17373.3.3.1.7
Current reading for Volts (Max)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

powMonVoltMin 1.3.6.1.4.1.17373.3.3.1.8
Current reading for Volts (Min)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

powMonVoltPeak 1.3.6.1.4.1.17373.3.3.1.9
Current reading for Volts (Peak)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

powMonDeciAmps 1.3.6.1.4.1.17373.3.3.1.10
Current reading for DeciAmps
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

powMonRealPower 1.3.6.1.4.1.17373.3.3.1.11
Current reading for Real Power
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

powMonApparentPower 1.3.6.1.4.1.17373.3.3.1.12
Current reading for Apparent Power
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

powMonPowerFactor 1.3.6.1.4.1.17373.3.3.1.13
Current reading for Power Factor
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

powMonOutlet1 1.3.6.1.4.1.17373.3.3.1.14
Outlet 1 Trap
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

powMonOutlet2 1.3.6.1.4.1.17373.3.3.1.15
Outlet 2 Trap
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

powMonOutlet1StatusTime 1.3.6.1.4.1.17373.3.3.1.16
Seconds Since Outlet 1 Last Changed Its Status
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

powMonOutlet2StatusTime 1.3.6.1.4.1.17373.3.3.1.17
Seconds Since Outlet 2 Last Changed Its Status
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

tempSensorEntry 1.3.6.1.4.1.17373.3.4.1
Entry in the temperature sensor table: each entry contains an index (tempIndex) and other sensor details
Status: current Access: not-accessible
OBJECT-TYPE    
  TempSensorEntry  

tempSensorIndex 1.3.6.1.4.1.17373.3.4.1.1
Table entry index value
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..100  

tempSensorSerial 1.3.6.1.4.1.17373.3.4.1.2
Serial Number
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

tempSensorName 1.3.6.1.4.1.17373.3.4.1.3
Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

tempSensorAvail 1.3.6.1.4.1.17373.3.4.1.4
Is device currently plugged in?
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

tempSensorTempC 1.3.6.1.4.1.17373.3.4.1.5
Temperature in Celsius
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER -50..100  

tempSensorTempF 1.3.6.1.4.1.17373.3.4.1.6
Temperature in Fahrenheit
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER -58..212  

airFlowSensorEntry 1.3.6.1.4.1.17373.3.5.1
Entry in the air flow sensor table: each entry contains an index (airFlowSensorIndex) and other sensor details
Status: current Access: not-accessible
OBJECT-TYPE    
  AirFlowSensorEntry  

airFlowSensorIndex 1.3.6.1.4.1.17373.3.5.1.1
Table entry index value
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..100  

airFlowSensorSerial 1.3.6.1.4.1.17373.3.5.1.2
Serial Number
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

airFlowSensorName 1.3.6.1.4.1.17373.3.5.1.3
Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

airFlowSensorAvail 1.3.6.1.4.1.17373.3.5.1.4
Is device currently plugged in?
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

airFlowSensorTempC 1.3.6.1.4.1.17373.3.5.1.5
Temperature reading in C
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER -50..100  

airFlowSensorTempF 1.3.6.1.4.1.17373.3.5.1.6
Temperature reading in F
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER -58..212  

airFlowSensorFlow 1.3.6.1.4.1.17373.3.5.1.7
Air flow reading
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

airFlowSensorHumidity 1.3.6.1.4.1.17373.3.5.1.8
Humidity reading
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

airFlowSensorDewPointC 1.3.6.1.4.1.17373.3.5.1.9
Current reading for Dew Point (C)
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER -50..100  

airFlowSensorDewPointF 1.3.6.1.4.1.17373.3.5.1.10
Current reading for Dew Point (F)
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER -58..212  

ctrl3ChDELTAEntry 1.3.6.1.4.1.17373.3.6.1
Entry in the 3 phase delta outlet control table: each entry contains an index (ctrl3ChDELTAIndex) and other outlet control monitoring details
Status: current Access: not-accessible
OBJECT-TYPE    
  Ctrl3ChDELTAEntry  

ctrl3ChDELTAIndex 1.3.6.1.4.1.17373.3.6.1.1
Table entry index value
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..100  

ctrl3ChDELTASerial 1.3.6.1.4.1.17373.3.6.1.2
Serial Number
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

ctrl3ChDELTAName 1.3.6.1.4.1.17373.3.6.1.3
Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

ctrl3ChDELTAAvail 1.3.6.1.4.1.17373.3.6.1.4
Is device currently plugged in?
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl3ChDELTAPowerChCount 1.3.6.1.4.1.17373.3.6.1.5
Number of active power channels
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..3  

ctrl3ChDELTADeciAmpsA 1.3.6.1.4.1.17373.3.6.1.6
Current reading for DeciAmps (Line A)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl3ChDELTADeciAmpsB 1.3.6.1.4.1.17373.3.6.1.7
Current reading for DeciAmps (Line B)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl3ChDELTADeciAmpsC 1.3.6.1.4.1.17373.3.6.1.8
Current reading for DeciAmps (Line C)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl3ChDELTAkWattHrsTotal 1.3.6.1.4.1.17373.3.6.1.9
Current Reading for kWatt-Hours (Total)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl3ChDELTARealPowerTotal 1.3.6.1.4.1.17373.3.6.1.10
Current reading for Watts (Total)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl3ChDELTAkWattHrsAB 1.3.6.1.4.1.17373.3.6.1.11
Current Reading for kWatt-Hours (Phase AB)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl3ChDELTAVoltsAB 1.3.6.1.4.1.17373.3.6.1.12
Current reading for Volts (Phase AB)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl3ChDELTAVoltPeakAB 1.3.6.1.4.1.17373.3.6.1.13
Current reading for Peak-Volts (Phase AB)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl3ChDELTARealPowerAB 1.3.6.1.4.1.17373.3.6.1.14
Current reading for Real Power (Phase AB)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl3ChDELTAApparentPowerAB 1.3.6.1.4.1.17373.3.6.1.15
Current reading for VoltAmps (Phase AB)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl3ChDELTAPowerFactorAB 1.3.6.1.4.1.17373.3.6.1.16
Current reading for Power Factor (Phase AB)
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

ctrl3ChDELTAkWattHrsBC 1.3.6.1.4.1.17373.3.6.1.17
Current Reading for kWatt-Hours (Phase BC)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl3ChDELTAVoltsBC 1.3.6.1.4.1.17373.3.6.1.18
Current reading for Volts (Phase BC)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl3ChDELTAVoltPeakBC 1.3.6.1.4.1.17373.3.6.1.19
Current reading for Peak-Volts (Phase BC)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl3ChDELTARealPowerBC 1.3.6.1.4.1.17373.3.6.1.20
Current reading for Real Power (Phase BC)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl3ChDELTAApparentPowerBC 1.3.6.1.4.1.17373.3.6.1.21
Current reading for VoltAmps (Phase BC)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl3ChDELTAPowerFactorBC 1.3.6.1.4.1.17373.3.6.1.22
Current reading for Power Factor (Phase BC)
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

ctrl3ChDELTAkWattHrsCA 1.3.6.1.4.1.17373.3.6.1.23
Current Reading for kWatt-Hours (Phase CA)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl3ChDELTAVoltsCA 1.3.6.1.4.1.17373.3.6.1.24
Current reading for Volts (Phase CA)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl3ChDELTAVoltPeakCA 1.3.6.1.4.1.17373.3.6.1.25
Current reading for Peak-Volts (Phase CA)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl3ChDELTARealPowerCA 1.3.6.1.4.1.17373.3.6.1.26
Current reading for Real Power (Phase CA)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl3ChDELTAApparentPowerCA 1.3.6.1.4.1.17373.3.6.1.27
Current reading for VoltAmps (Phase CA)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl3ChDELTAPowerFactorCA 1.3.6.1.4.1.17373.3.6.1.28
Current reading for Power Factor (Phase CA)
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

doorSensorEntry 1.3.6.1.4.1.17373.3.7.1
Entry in the door sensor table: each entry contains an index (doorSensorIndex) and other sensor details
Status: current Access: not-accessible
OBJECT-TYPE    
  DoorSensorEntry  

doorSensorIndex 1.3.6.1.4.1.17373.3.7.1.1
Table entry index value
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..100  

doorSensorSerial 1.3.6.1.4.1.17373.3.7.1.2
Serial Number
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

doorSensorName 1.3.6.1.4.1.17373.3.7.1.3
Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

doorSensorAvail 1.3.6.1.4.1.17373.3.7.1.4
Is device currently plugged in?
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

doorSensorStatus 1.3.6.1.4.1.17373.3.7.1.5
Door sensor status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

waterSensorEntry 1.3.6.1.4.1.17373.3.8.1
Entry in the water sensor table: each entry contains an index (waterSensorIndex) and other sensor details
Status: current Access: not-accessible
OBJECT-TYPE    
  WaterSensorEntry  

waterSensorIndex 1.3.6.1.4.1.17373.3.8.1.1
Table entry index value
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..100  

waterSensorSerial 1.3.6.1.4.1.17373.3.8.1.2
Serial Number
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

waterSensorName 1.3.6.1.4.1.17373.3.8.1.3
Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

waterSensorAvail 1.3.6.1.4.1.17373.3.8.1.4
Is device currently plugged in?
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

waterSensorDampness 1.3.6.1.4.1.17373.3.8.1.5
Dampness of the water sensor
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

currentMonitorEntry 1.3.6.1.4.1.17373.3.9.1
Entry in the current monitor table: each entry contains an index (currentMonitorIndex) and other sensor details
Status: current Access: not-accessible
OBJECT-TYPE    
  CurrentMonitorEntry  

currentMonitorIndex 1.3.6.1.4.1.17373.3.9.1.1
Table entry index value
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..100  

currentMonitorSerial 1.3.6.1.4.1.17373.3.9.1.2
Serial Number
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

currentMonitorName 1.3.6.1.4.1.17373.3.9.1.3
Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

currentMonitorAvail 1.3.6.1.4.1.17373.3.9.1.4
Is device currently plugged in?
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

currentMonitorDeciAmps 1.3.6.1.4.1.17373.3.9.1.5
Current in deciamps
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..30  

millivoltMonitorEntry 1.3.6.1.4.1.17373.3.10.1
Entry in the millivolt monitor table: each entry contains an index (millivoltMonitorIndex) and other sensor details
Status: current Access: not-accessible
OBJECT-TYPE    
  MillivoltMonitorEntry  

millivoltMonitorIndex 1.3.6.1.4.1.17373.3.10.1.1
Table entry index value
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..100  

millivoltMonitorSerial 1.3.6.1.4.1.17373.3.10.1.2
Serial Number
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

millivoltMonitorName 1.3.6.1.4.1.17373.3.10.1.3
Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

millivoltMonitorAvail 1.3.6.1.4.1.17373.3.10.1.4
Is device currently plugged in?
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

millivoltMonitorMV 1.3.6.1.4.1.17373.3.10.1.5
millivolts
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..5000  

pow3ChEntry 1.3.6.1.4.1.17373.3.11.1
Entry in the power monitor 3 channel table: each entry contains an index (pow3ChIndex) and other power monitoring details
Status: current Access: not-accessible
OBJECT-TYPE    
  Pow3ChEntry  

pow3ChIndex 1.3.6.1.4.1.17373.3.11.1.1
Table entry index value
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..100  

pow3ChSerial 1.3.6.1.4.1.17373.3.11.1.2
Serial Number
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

pow3ChName 1.3.6.1.4.1.17373.3.11.1.3
Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

pow3ChAvail 1.3.6.1.4.1.17373.3.11.1.4
Is device currently plugged in?
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

pow3ChkWattHrsA 1.3.6.1.4.1.17373.3.11.1.5
Current reading for kWatt-Hours (Phase A)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

pow3ChVoltsA 1.3.6.1.4.1.17373.3.11.1.6
Current reading for Volts (Phase A)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

pow3ChVoltMaxA 1.3.6.1.4.1.17373.3.11.1.7
Current reading for Max-Volts (Phase A)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

pow3ChVoltMinA 1.3.6.1.4.1.17373.3.11.1.8
Current reading for Min-Volts (Phase A)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

pow3ChVoltPeakA 1.3.6.1.4.1.17373.3.11.1.9
Current reading for Peak-Volts (Phase A)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

pow3ChDeciAmpsA 1.3.6.1.4.1.17373.3.11.1.10
Current reading for DeciAmps (Phase A)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

pow3ChRealPowerA 1.3.6.1.4.1.17373.3.11.1.11
Current reading for Real Power (Phase A)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

pow3ChApparentPowerA 1.3.6.1.4.1.17373.3.11.1.12
Current reading for Apparent Power (Phase A)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

pow3ChPowerFactorA 1.3.6.1.4.1.17373.3.11.1.13
Current reading for Power Factor (Phase A)
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

pow3ChkWattHrsB 1.3.6.1.4.1.17373.3.11.1.14
Current reading for kWatt-Hours (Phase B)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

pow3ChVoltsB 1.3.6.1.4.1.17373.3.11.1.15
Current reading for Volts (Phase B)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

pow3ChVoltMaxB 1.3.6.1.4.1.17373.3.11.1.16
Current reading for Max-Volts (Phase B)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

pow3ChVoltMinB 1.3.6.1.4.1.17373.3.11.1.17
Current reading for Min-Volts (Phase B)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

pow3ChVoltPeakB 1.3.6.1.4.1.17373.3.11.1.18
Current reading for Peak-Volts (Phase B)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

pow3ChDeciAmpsB 1.3.6.1.4.1.17373.3.11.1.19
Current reading for DeciAmps (Phase B)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

pow3ChRealPowerB 1.3.6.1.4.1.17373.3.11.1.20
Current reading for Real Power (Phase B)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

pow3ChApparentPowerB 1.3.6.1.4.1.17373.3.11.1.21
Current reading for Apparent Power (Phase B)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

pow3ChPowerFactorB 1.3.6.1.4.1.17373.3.11.1.22
Current reading for Power Factor (Phase B)
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

pow3ChkWattHrsC 1.3.6.1.4.1.17373.3.11.1.23
Current reading for kWatt-Hours (Phase C)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

pow3ChVoltsC 1.3.6.1.4.1.17373.3.11.1.24
Current reading for Volts (Phase C)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

pow3ChVoltMaxC 1.3.6.1.4.1.17373.3.11.1.25
Current reading for Max-Volts (Phase C)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

pow3ChVoltMinC 1.3.6.1.4.1.17373.3.11.1.26
Current reading for Min-Volts (Phase C)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

pow3ChVoltPeakC 1.3.6.1.4.1.17373.3.11.1.27
Current reading for Peak-Volts (Phase C)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

pow3ChDeciAmpsC 1.3.6.1.4.1.17373.3.11.1.28
Current reading for DeciAmps (Phase C)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

pow3ChRealPowerC 1.3.6.1.4.1.17373.3.11.1.29
Current reading for Real Power (Phase C)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

pow3ChApparentPowerC 1.3.6.1.4.1.17373.3.11.1.30
Current reading for Apparent Power (Phase C)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

pow3ChPowerFactorC 1.3.6.1.4.1.17373.3.11.1.31
Current reading for Power Factor (Phase C)
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

pow3ChkWattHrsTotal 1.3.6.1.4.1.17373.3.11.1.32
Current reading for kWatt-Hours (Total)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

pow3ChRealPowerTotal 1.3.6.1.4.1.17373.3.11.1.33
Current reading for Real Power (Total)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

outletEntry 1.3.6.1.4.1.17373.3.12.1
Entry in the outlet table: each entry contains an index (outletIndex) and other sensor details
Status: current Access: not-accessible
OBJECT-TYPE    
  OutletEntry  

outletIndex 1.3.6.1.4.1.17373.3.12.1.1
Table entry index value
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..100  

outletSerial 1.3.6.1.4.1.17373.3.12.1.2
Serial Number
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

outletName 1.3.6.1.4.1.17373.3.12.1.3
Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

outletAvail 1.3.6.1.4.1.17373.3.12.1.4
Is device currently plugged in?
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

outlet1Status 1.3.6.1.4.1.17373.3.12.1.5
Outlet 1 status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

outlet2Status 1.3.6.1.4.1.17373.3.12.1.6
Outlet 2 status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

vsfcEntry 1.3.6.1.4.1.17373.3.13.1
Entry in the vsfc table: each entry contains an index (vsfcIndex) and other details
Status: current Access: not-accessible
OBJECT-TYPE    
  VsfcEntry  

vsfcIndex 1.3.6.1.4.1.17373.3.13.1.1
Table entry index value
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..1  

vsfcSerial 1.3.6.1.4.1.17373.3.13.1.2
Serial Number
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

vsfcName 1.3.6.1.4.1.17373.3.13.1.3
Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

vsfcAvail 1.3.6.1.4.1.17373.3.13.1.4
Is device currently plugged in?
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

vsfcSetPointC 1.3.6.1.4.1.17373.3.13.1.5
Current temperature set point in C
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 18..38  

vsfcSetPointF 1.3.6.1.4.1.17373.3.13.1.6
Current temperature set point in F
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 65..100  

vsfcFanSpeed 1.3.6.1.4.1.17373.3.13.1.7
Current reading for Fan Speed
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

vsfcIntTempC 1.3.6.1.4.1.17373.3.13.1.8
Current internal temperature reading in C
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER -20..50  

vsfcIntTempF 1.3.6.1.4.1.17373.3.13.1.9
Current internal temperature reading in F
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER -4..122  

vsfcExt1TempC 1.3.6.1.4.1.17373.3.13.1.10
Current reading for external temp 1 in C
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER -20..50  

vsfcExt1TempF 1.3.6.1.4.1.17373.3.13.1.11
Current reading for external temp 1 in F
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER -20..122  

vsfcExt2TempC 1.3.6.1.4.1.17373.3.13.1.12
Current reading for external temp 2 in C
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER -20..50  

vsfcExt2TempF 1.3.6.1.4.1.17373.3.13.1.13
Current reading for external temp 1 in F
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER -20..122  

vsfcExt3TempC 1.3.6.1.4.1.17373.3.13.1.14
Current reading for external temp 3 in C
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER -20..50  

vsfcExt3TempF 1.3.6.1.4.1.17373.3.13.1.15
Current reading for external temp 1 in F
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER -20..122  

vsfcExt4TempC 1.3.6.1.4.1.17373.3.13.1.16
Current reading for external temp 4 in C
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER -20..50  

vsfcExt4TempF 1.3.6.1.4.1.17373.3.13.1.17
Current reading for external temp 1 in F
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER -20..122  

ctrl3ChEntry 1.3.6.1.4.1.17373.3.14.1
Entry in the 3 phase outlet control table: each entry contains an index (ctrl3ChIndex) and other outlet control monitoring details
Status: current Access: not-accessible
OBJECT-TYPE    
  Ctrl3ChEntry  

ctrl3ChIndex 1.3.6.1.4.1.17373.3.14.1.1
Table entry index value
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..1  

ctrl3ChSerial 1.3.6.1.4.1.17373.3.14.1.2
Serial Number
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

ctrl3ChName 1.3.6.1.4.1.17373.3.14.1.3
Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

ctrl3ChAvail 1.3.6.1.4.1.17373.3.14.1.4
Is device currently plugged in?
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl3ChVoltsA 1.3.6.1.4.1.17373.3.14.1.5
Current reading for Volts (Phase A)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl3ChVoltPeakA 1.3.6.1.4.1.17373.3.14.1.6
Current reading for Peak-Volts (Phase A)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl3ChDeciAmpsA 1.3.6.1.4.1.17373.3.14.1.7
Current reading for DeciAmps (Phase A)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl3ChDeciAmpsPeakA 1.3.6.1.4.1.17373.3.14.1.8
Current reading for Peak-DeciAmps (Phase A)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl3ChRealPowerA 1.3.6.1.4.1.17373.3.14.1.9
Current reading for Real Power (Phase A)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl3ChApparentPowerA 1.3.6.1.4.1.17373.3.14.1.10
Current reading for Apparent Power (Phase A)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl3ChPowerFactorA 1.3.6.1.4.1.17373.3.14.1.11
Current reading for Power Factor (Phase A)
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

ctrl3ChVoltsB 1.3.6.1.4.1.17373.3.14.1.12
Current reading for Volts (Phase B)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl3ChVoltPeakB 1.3.6.1.4.1.17373.3.14.1.13
Current reading for Peak-Volts (Phase B)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl3ChDeciAmpsB 1.3.6.1.4.1.17373.3.14.1.14
Current reading for DeciAmps (Phase B)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl3ChDeciAmpsPeakB 1.3.6.1.4.1.17373.3.14.1.15
Current reading for Peak-DeciAmps (Phase B)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl3ChRealPowerB 1.3.6.1.4.1.17373.3.14.1.16
Current reading for Real Power (Phase B)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl3ChApparentPowerB 1.3.6.1.4.1.17373.3.14.1.17
Current reading for Apparent Power (Phase B)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl3ChPowerFactorB 1.3.6.1.4.1.17373.3.14.1.18
Current reading for Power Factor (Phase B)
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

ctrl3ChVoltsC 1.3.6.1.4.1.17373.3.14.1.19
Current reading for Volts (Phase C)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl3ChVoltPeakC 1.3.6.1.4.1.17373.3.14.1.20
Current reading for Peak-Volts (Phase C)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl3ChDeciAmpsC 1.3.6.1.4.1.17373.3.14.1.21
Current reading for DeciAmps (Phase C)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl3ChDeciAmpsPeakC 1.3.6.1.4.1.17373.3.14.1.22
Current reading for Peak-DeciAmps (Phase C)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl3ChRealPowerC 1.3.6.1.4.1.17373.3.14.1.23
Current reading for Real Power (Phase C)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl3ChApparentPowerC 1.3.6.1.4.1.17373.3.14.1.24
Current reading for Apparent Power (Phase C)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl3ChPowerFactorC 1.3.6.1.4.1.17373.3.14.1.25
Current reading for Power Factor (Phase C)
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

ctrlGrpAmpsEntry 1.3.6.1.4.1.17373.3.15.1
Entry in the Control Group Amps table: each entry contains an index (ctrlGrpAmpsIndex) and other sensor details
Status: current Access: not-accessible
OBJECT-TYPE    
  CtrlGrpAmpsEntry  

ctrlGrpAmpsIndex 1.3.6.1.4.1.17373.3.15.1.1
Table entry index value
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..1  

ctrlGrpAmpsSerial 1.3.6.1.4.1.17373.3.15.1.2
Serial Number
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

ctrlGrpAmpsName 1.3.6.1.4.1.17373.3.15.1.3
Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

ctrlGrpAmpsAvail 1.3.6.1.4.1.17373.3.15.1.4
Is device currently plugged in?
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrlGrpAmpsA 1.3.6.1.4.1.17373.3.15.1.5
DeciAmps Group A
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrlGrpAmpsB 1.3.6.1.4.1.17373.3.15.1.6
DeciAmps Group B
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrlGrpAmpsC 1.3.6.1.4.1.17373.3.15.1.7
DeciAmps Group C
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrlGrpAmpsD 1.3.6.1.4.1.17373.3.15.1.8
DeciAmps Group D
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrlGrpAmpsE 1.3.6.1.4.1.17373.3.15.1.9
DeciAmps Group E
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrlGrpAmpsF 1.3.6.1.4.1.17373.3.15.1.10
DeciAmps Group F
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrlGrpAmpsG 1.3.6.1.4.1.17373.3.15.1.11
DeciAmps Group G
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrlGrpAmpsH 1.3.6.1.4.1.17373.3.15.1.12
DeciAmps Group H
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrlGrpAmpsAVolts 1.3.6.1.4.1.17373.3.15.1.13
Volts Group A
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrlGrpAmpsBVolts 1.3.6.1.4.1.17373.3.15.1.14
Volts Group B
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrlGrpAmpsCVolts 1.3.6.1.4.1.17373.3.15.1.15
Volts Group C
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrlGrpAmpsDVolts 1.3.6.1.4.1.17373.3.15.1.16
Volts Group D
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrlGrpAmpsEVolts 1.3.6.1.4.1.17373.3.15.1.17
Volts Group E
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrlGrpAmpsFVolts 1.3.6.1.4.1.17373.3.15.1.18
Volts Group F
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrlGrpAmpsGVolts 1.3.6.1.4.1.17373.3.15.1.19
Volts Group G
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrlGrpAmpsHVolts 1.3.6.1.4.1.17373.3.15.1.20
Volts Group H
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrlGrpAmpsI 1.3.6.1.4.1.17373.3.15.1.21
DeciAmps Group I
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrlGrpAmpsJ 1.3.6.1.4.1.17373.3.15.1.22
DeciAmps Group J
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrlGrpAmpsK 1.3.6.1.4.1.17373.3.15.1.23
DeciAmps Group K
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrlGrpAmpsL 1.3.6.1.4.1.17373.3.15.1.24
DeciAmps Group L
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrlGrpAmpsM 1.3.6.1.4.1.17373.3.15.1.25
DeciAmps Group M
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrlGrpAmpsN 1.3.6.1.4.1.17373.3.15.1.26
DeciAmps Group N
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrlGrpAmpsO 1.3.6.1.4.1.17373.3.15.1.27
DeciAmps Group O
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrlGrpAmpsP 1.3.6.1.4.1.17373.3.15.1.28
DeciAmps Group P
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrlGrpAmpsIVolts 1.3.6.1.4.1.17373.3.15.1.29
Volts Group I
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrlGrpAmpsJVolts 1.3.6.1.4.1.17373.3.15.1.30
Volts Group J
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrlGrpAmpsKVolts 1.3.6.1.4.1.17373.3.15.1.31
Volts Group K
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrlGrpAmpsLVolts 1.3.6.1.4.1.17373.3.15.1.32
Volts Group L
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrlGrpAmpsMVolts 1.3.6.1.4.1.17373.3.15.1.33
Volts Group M
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrlGrpAmpsNVolts 1.3.6.1.4.1.17373.3.15.1.34
Volts Group N
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrlGrpAmpsOVolts 1.3.6.1.4.1.17373.3.15.1.35
Volts Group O
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrlGrpAmpsPVolts 1.3.6.1.4.1.17373.3.15.1.36
Volts Group P
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrlOutletEntry 1.3.6.1.4.1.17373.3.16.1
Entry in the control outlet table: each entry contains an index (ctrlOutletIndex) and other sensor details
Status: current Access: not-accessible
OBJECT-TYPE    
  CtrlOutletEntry  

ctrlOutletIndex 1.3.6.1.4.1.17373.3.16.1.1
Outlet Number
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..100  

ctrlOutletName 1.3.6.1.4.1.17373.3.16.1.2
Outlet Friendly Name
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

ctrlOutletStatus 1.3.6.1.4.1.17373.3.16.1.3
Current Outlet Status: 0 = Off, 1 = On | Outlet Action Write: 0 = Cancel Pending, 1 = On, 2 = On Delayed, 3 = Off Immediate, 4 = Off Delayed, 5 = Reboot, 6 = Reboot Delayed, 7 = Clear kWh (POA units only)
Status: current Access: read-write
OBJECT-TYPE    
  Gauge32  

ctrlOutletFeedback 1.3.6.1.4.1.17373.3.16.1.4
Outlet Feedback Value, should be equal to status
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrlOutletPending 1.3.6.1.4.1.17373.3.16.1.5
Outlet Status Read to change to: 0 = Off, 1 = On | Outlet Action Write: 0 = Cancel Pending, 1 = On, 2 = On Delayed, 3 = Off Immediate, 4 = Off Delayed, 5 = Reboot, 6 = Reboot Delayed, 7 = Clear kWh (POA units only)
Status: current Access: read-write
OBJECT-TYPE    
  Gauge32  

ctrlOutletDeciAmps 1.3.6.1.4.1.17373.3.16.1.6
Outlet DeciAmps reading
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrlOutletGroup 1.3.6.1.4.1.17373.3.16.1.7
Outlet Group (A to G)
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

ctrlOutletUpDelay 1.3.6.1.4.1.17373.3.16.1.8
Outlet Power Up Delay
Status: current Access: read-write
OBJECT-TYPE    
  Gauge32  

ctrlOutletDwnDelay 1.3.6.1.4.1.17373.3.16.1.9
Outlet Power Down Delay
Status: current Access: read-write
OBJECT-TYPE    
  Gauge32  

ctrlOutletRbtDuration 1.3.6.1.4.1.17373.3.16.1.10
Outlet Reboot Duration
Status: current Access: read-write
OBJECT-TYPE    
  Gauge32  

ctrlOutletURL 1.3.6.1.4.1.17373.3.16.1.11
Outlet URL
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

ctrlOutletPOAAction 1.3.6.1.4.1.17373.3.16.1.12
POA Action: 1 = Off, 2 = On, 3 = Last, 0 = POA not supported on this unit type
Status: current Access: read-write
OBJECT-TYPE    
  Gauge32  

ctrlOutletPOADelay 1.3.6.1.4.1.17373.3.16.1.13
POA Delay
Status: current Access: read-write
OBJECT-TYPE    
  Gauge32  

ctrlOutletkWattHrs 1.3.6.1.4.1.17373.3.16.1.14
Current Reading for kWatt-Hours
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrlOutletPower 1.3.6.1.4.1.17373.3.16.1.15
Current reading for Power
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrlOutletRbtDelay 1.3.6.1.4.1.17373.3.16.1.16
Outlet Reboot Delay
Status: current Access: read-write
OBJECT-TYPE    
  Gauge32  

ctrlOutletStatusTime 1.3.6.1.4.1.17373.3.16.1.17
Seconds Since Outlet Last Changed Its Status
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

dewPointSensorEntry 1.3.6.1.4.1.17373.3.17.1
Entry in the dew point sensor table: each entry contains an index (dewPointSensorIndex) and other sensor details
Status: current Access: not-accessible
OBJECT-TYPE    
  DewPointSensorEntry  

dewPointSensorIndex 1.3.6.1.4.1.17373.3.17.1.1
Table entry index value
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..100  

dewPointSensorSerial 1.3.6.1.4.1.17373.3.17.1.2
Serial Number
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

dewPointSensorName 1.3.6.1.4.1.17373.3.17.1.3
Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

dewPointSensorAvail 1.3.6.1.4.1.17373.3.17.1.4
Is device currently plugged in?
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

dewPointSensorTempC 1.3.6.1.4.1.17373.3.17.1.5
Temperature reading in C
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER -50..100  

dewPointSensorTempF 1.3.6.1.4.1.17373.3.17.1.6
Temperature reading in F
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER -58..212  

dewPointSensorHumidity 1.3.6.1.4.1.17373.3.17.1.7
Humidity reading
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

dewPointSensorDewPointC 1.3.6.1.4.1.17373.3.17.1.8
Dew point reading in C
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER -50..100  

dewPointSensorDewPointF 1.3.6.1.4.1.17373.3.17.1.9
Dew point reading in F
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER -58..212  

digitalSensorEntry 1.3.6.1.4.1.17373.3.18.1
Entry in the digital sensor table: each entry contains an index (digitalSensorIndex) and other sensor details
Status: current Access: not-accessible
OBJECT-TYPE    
  DigitalSensorEntry  

digitalSensorIndex 1.3.6.1.4.1.17373.3.18.1.1
Table entry index value
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..100  

digitalSensorSerial 1.3.6.1.4.1.17373.3.18.1.2
Serial Number
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

digitalSensorName 1.3.6.1.4.1.17373.3.18.1.3
Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

digitalSensorAvail 1.3.6.1.4.1.17373.3.18.1.4
Is device currently plugged in?
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

digitalSensorDigital 1.3.6.1.4.1.17373.3.18.1.5
Digital sensor status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

dstsEntry 1.3.6.1.4.1.17373.3.19.1
Entry in the DSTS table: each entry contains an index (dstsIndex) and other details
Status: current Access: not-accessible
OBJECT-TYPE    
  DstsEntry  

dstsIndex 1.3.6.1.4.1.17373.3.19.1.1
Table entry index value
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..1  

dstsSerial 1.3.6.1.4.1.17373.3.19.1.2
Serial Number
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

dstsName 1.3.6.1.4.1.17373.3.19.1.3
Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

dstsAvail 1.3.6.1.4.1.17373.3.19.1.4
Is device currently plugged in?
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

dstsVoltsA 1.3.6.1.4.1.17373.3.19.1.5
RMS Voltage of Side A
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

dstsDeciAmpsA 1.3.6.1.4.1.17373.3.19.1.6
RMS Current of Side A in deciamps
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

dstsVoltsB 1.3.6.1.4.1.17373.3.19.1.7
RMS Voltage of Side B
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

dstsDeciAmpsB 1.3.6.1.4.1.17373.3.19.1.8
RMS Current of Side B in deciamps
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

dstsSourceAActive 1.3.6.1.4.1.17373.3.19.1.9
If 99, source A active
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

dstsSourceBActive 1.3.6.1.4.1.17373.3.19.1.10
If 99, source B active
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

dstsPowerStatusA 1.3.6.1.4.1.17373.3.19.1.11
Power Quality of source A
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

dstsPowerStatusB 1.3.6.1.4.1.17373.3.19.1.12
Power Quality of Source B
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

dstsSourceATempC 1.3.6.1.4.1.17373.3.19.1.13
Current reading for Source A temp in C
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER -20..50  

dstsSourceBTempC 1.3.6.1.4.1.17373.3.19.1.14
Current reading for Source B temp in C
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER -20..50  

cpmSensorEntry 1.3.6.1.4.1.17373.3.20.1
Entry in the city power sensor table: each entry contains an index (cpmSensorIndex) and other sensor details
Status: current Access: not-accessible
OBJECT-TYPE    
  CpmSensorEntry  

cpmSensorIndex 1.3.6.1.4.1.17373.3.20.1.1
Table entry index value
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..100  

cpmSensorSerial 1.3.6.1.4.1.17373.3.20.1.2
Serial Number
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

cpmSensorName 1.3.6.1.4.1.17373.3.20.1.3
Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

cpmSensorAvail 1.3.6.1.4.1.17373.3.20.1.4
Is device currently plugged in?
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

cpmSensorStatus 1.3.6.1.4.1.17373.3.20.1.5
City Power sensor status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

smokeAlarmEntry 1.3.6.1.4.1.17373.3.21.1
Entry in the smoke alarm sensor table: each entry contains an index (smokeAlarmIndex) and other sensor details
Status: current Access: not-accessible
OBJECT-TYPE    
  SmokeAlarmEntry  

smokeAlarmIndex 1.3.6.1.4.1.17373.3.21.1.1
Table entry index value
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..100  

smokeAlarmSerial 1.3.6.1.4.1.17373.3.21.1.2
Serial Number
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

smokeAlarmName 1.3.6.1.4.1.17373.3.21.1.3
Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

smokeAlarmAvail 1.3.6.1.4.1.17373.3.21.1.4
Is device currently plugged in?
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

smokeAlarmStatus 1.3.6.1.4.1.17373.3.21.1.5
Smoke alarm status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

neg48VdcSensorEntry 1.3.6.1.4.1.17373.3.22.1
Entry in the -48Vdc sensor table: each entry contains an index (neg48VdcSensorIndex) and other sensor details
Status: current Access: not-accessible
OBJECT-TYPE    
  Neg48VdcSensorEntry  

neg48VdcSensorIndex 1.3.6.1.4.1.17373.3.22.1.1
Table entry index value
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..100  

neg48VdcSensorSerial 1.3.6.1.4.1.17373.3.22.1.2
Serial Number
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

neg48VdcSensorName 1.3.6.1.4.1.17373.3.22.1.3
Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

neg48VdcSensorAvail 1.3.6.1.4.1.17373.3.22.1.4
Is device currently plugged in?
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

neg48VdcSensorVoltage 1.3.6.1.4.1.17373.3.22.1.5
-48Vdc Sensor value
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER -100..10  

pos30VdcSensorEntry 1.3.6.1.4.1.17373.3.23.1
Entry in the 30Vdc sensor table: each entry contains an index (pos30VdcSensorIndex) and other sensor details
Status: current Access: not-accessible
OBJECT-TYPE    
  Pos30VdcSensorEntry  

pos30VdcSensorIndex 1.3.6.1.4.1.17373.3.23.1.1
Table entry index value
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..100  

pos30VdcSensorSerial 1.3.6.1.4.1.17373.3.23.1.2
Serial Number
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

pos30VdcSensorName 1.3.6.1.4.1.17373.3.23.1.3
Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

pos30VdcSensorAvail 1.3.6.1.4.1.17373.3.23.1.4
Is device currently plugged in?
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

pos30VdcSensorVoltage 1.3.6.1.4.1.17373.3.23.1.5
30Vdc Sensor value
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER -10..100  

analogSensorEntry 1.3.6.1.4.1.17373.3.24.1
Entry in the analog input table: each entry contains an index (analogSensorIndex) and other sensor details
Status: current Access: not-accessible
OBJECT-TYPE    
  AnalogSensorEntry  

analogSensorIndex 1.3.6.1.4.1.17373.3.24.1.1
Table entry index value
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..100  

analogSensorSerial 1.3.6.1.4.1.17373.3.24.1.2
Serial Number
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

analogSensorName 1.3.6.1.4.1.17373.3.24.1.3
Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

analogSensorAvail 1.3.6.1.4.1.17373.3.24.1.4
Is device currently plugged in?
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

analogSensorAnalog 1.3.6.1.4.1.17373.3.24.1.5
Analog Sensor Value
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

ctrl3ChIECEntry 1.3.6.1.4.1.17373.3.25.1
Entry in the 3 phase outlet control table: each entry contains an index (ctrl3ChIECIndex) and other outlet control monitoring details
Status: current Access: not-accessible
OBJECT-TYPE    
  Ctrl3ChIECEntry  

ctrl3ChIECIndex 1.3.6.1.4.1.17373.3.25.1.1
Table entry index value
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..100  

ctrl3ChIECSerial 1.3.6.1.4.1.17373.3.25.1.2
Serial Number
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

ctrl3ChIECName 1.3.6.1.4.1.17373.3.25.1.3
Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

ctrl3ChIECAvail 1.3.6.1.4.1.17373.3.25.1.4
Is device currently plugged in?
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl3ChIECkWattHrsA 1.3.6.1.4.1.17373.3.25.1.5
Current Reading for kWatt-Hours (Phase A)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl3ChIECVoltsA 1.3.6.1.4.1.17373.3.25.1.6
Current reading for Volts (Phase A)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl3ChIECVoltPeakA 1.3.6.1.4.1.17373.3.25.1.7
Current reading for Peak-Volts (Phase A)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl3ChIECDeciAmpsA 1.3.6.1.4.1.17373.3.25.1.8
Current reading for DeciAmps (Phase A)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl3ChIECDeciAmpsPeakA 1.3.6.1.4.1.17373.3.25.1.9
Current reading for Peak-DeciAmps (Phase A)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl3ChIECRealPowerA 1.3.6.1.4.1.17373.3.25.1.10
Current reading for Real Power (Phase A)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl3ChIECApparentPowerA 1.3.6.1.4.1.17373.3.25.1.11
Current reading for Apparent Power (Phase A)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl3ChIECPowerFactorA 1.3.6.1.4.1.17373.3.25.1.12
Current reading for Power Factor (Phase A)
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

ctrl3ChIECkWattHrsB 1.3.6.1.4.1.17373.3.25.1.13
Current Reading for kWatt-Hours (Phase B)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl3ChIECVoltsB 1.3.6.1.4.1.17373.3.25.1.14
Current reading for Volts (Phase B)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl3ChIECVoltPeakB 1.3.6.1.4.1.17373.3.25.1.15
Current reading for Peak-Volts (Phase B)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl3ChIECDeciAmpsB 1.3.6.1.4.1.17373.3.25.1.16
Current reading for DeciAmps (Phase B)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl3ChIECDeciAmpsPeakB 1.3.6.1.4.1.17373.3.25.1.17
Current reading for Peak-DeciAmps (Phase B)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl3ChIECRealPowerB 1.3.6.1.4.1.17373.3.25.1.18
Current reading for Real Power (Phase B)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl3ChIECApparentPowerB 1.3.6.1.4.1.17373.3.25.1.19
Current reading for Apparent Power (Phase B)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl3ChIECPowerFactorB 1.3.6.1.4.1.17373.3.25.1.20
Current reading for Power Factor (Phase B)
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

ctrl3ChIECkWattHrsC 1.3.6.1.4.1.17373.3.25.1.21
Current Reading for kWatt-Hours (Phase C)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl3ChIECVoltsC 1.3.6.1.4.1.17373.3.25.1.22
Current reading for Volts (Phase C)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl3ChIECVoltPeakC 1.3.6.1.4.1.17373.3.25.1.23
Current reading for Peak-Volts (Phase C)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl3ChIECDeciAmpsC 1.3.6.1.4.1.17373.3.25.1.24
Current reading for DeciAmps (Phase C)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl3ChIECDeciAmpsPeakC 1.3.6.1.4.1.17373.3.25.1.25
Current reading for Peak-DeciAmps (Phase C)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl3ChIECRealPowerC 1.3.6.1.4.1.17373.3.25.1.26
Current reading for Real Power (Phase C)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl3ChIECApparentPowerC 1.3.6.1.4.1.17373.3.25.1.27
Current reading for Apparent Power (Phase C)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl3ChIECPowerFactorC 1.3.6.1.4.1.17373.3.25.1.28
Current reading for Power Factor (Phase C)
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

ctrl3ChIECkWattHrsTotal 1.3.6.1.4.1.17373.3.25.1.29
Current Reading for kWatt-Hours (Total)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl3ChIECRealPowerTotal 1.3.6.1.4.1.17373.3.25.1.30
Current reading for Watts (Total)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

climateRelayEntry 1.3.6.1.4.1.17373.3.26.1
Entry in the climate table: each entry contains an index (climateRelayIndex) and other details
Status: current Access: not-accessible
OBJECT-TYPE    
  ClimateRelayEntry  

climateRelayIndex 1.3.6.1.4.1.17373.3.26.1.1
Table entry index value
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..1  

climateRelaySerial 1.3.6.1.4.1.17373.3.26.1.2
Serial Number
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

climateRelayName 1.3.6.1.4.1.17373.3.26.1.3
Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

climateRelayAvail 1.3.6.1.4.1.17373.3.26.1.4
Is device currently plugged in?
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

climateRelayTempC 1.3.6.1.4.1.17373.3.26.1.5
Current reading for Temperature (C)
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER -50..100  

climateRelayTempF 1.3.6.1.4.1.17373.3.26.1.6
Current reading for Temperature (F)
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER -58..212  

climateRelayIO1 1.3.6.1.4.1.17373.3.26.1.7
Current reading for Analog Input 1
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

climateRelayIO2 1.3.6.1.4.1.17373.3.26.1.8
Current reading for Analog Input 2
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

climateRelayIO3 1.3.6.1.4.1.17373.3.26.1.9
Current reading for Analog Input 3
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

climateRelayIO4 1.3.6.1.4.1.17373.3.26.1.10
Current reading for Analog Input 4
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

climateRelayIO5 1.3.6.1.4.1.17373.3.26.1.11
Current reading for Analog Input 5
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

climateRelayIO6 1.3.6.1.4.1.17373.3.26.1.12
Current reading for Analog Input 6
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

ctrlRelayEntry 1.3.6.1.4.1.17373.3.27.1
Entry in the control relay table: each entry contains an index (ctrlRelayIndex) and other sensor details
Status: current Access: not-accessible
OBJECT-TYPE    
  CtrlRelayEntry  

ctrlRelayIndex 1.3.6.1.4.1.17373.3.27.1.1
Relay Number
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..100  

ctrlRelayName 1.3.6.1.4.1.17373.3.27.1.2
Relay Friendly Name
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

ctrlRelayState 1.3.6.1.4.1.17373.3.27.1.3
Current Relay Status: 0 = Off, 1 = On
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrlRelayLatchingMode 1.3.6.1.4.1.17373.3.27.1.4
Relay latching mode: 0 = Non-latching, 1 = Latching
Status: current Access: read-write
OBJECT-TYPE    
  Gauge32  

ctrlRelayOverride 1.3.6.1.4.1.17373.3.27.1.5
Relay Override Mode: 0 - None, 1 - On, 2 - Off
Status: current Access: read-write
OBJECT-TYPE    
  Gauge32  

ctrlRelayAcknowledge 1.3.6.1.4.1.17373.3.27.1.6
Acknowledge write a 1, always reads back 0
Status: current Access: read-write
OBJECT-TYPE    
  Gauge32  

airSpeedSwitchSensorEntry 1.3.6.1.4.1.17373.3.28.1
Entry in the air speed switch sensor table: each entry contains an index (airSpeedSwitchIndex) and other sensor details
Status: current Access: not-accessible
OBJECT-TYPE    
  AirSpeedSwitchSensorEntry  

airSpeedSwitchSensorIndex 1.3.6.1.4.1.17373.3.28.1.1
Table entry index value
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..100  

airSpeedSwitchSensorSerial 1.3.6.1.4.1.17373.3.28.1.2
Serial Number
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

airSpeedSwitchSensorName 1.3.6.1.4.1.17373.3.28.1.3
Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

airSpeedSwitchSensorAvail 1.3.6.1.4.1.17373.3.28.1.4
Is device currently plugged in?
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

airSpeedSwitchSensorAirSpeed 1.3.6.1.4.1.17373.3.28.1.5
Air Speed Switch Status
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

powerDMEntry 1.3.6.1.4.1.17373.3.29.1
Entry in the DM48 current monitor table: each entry contains an index (powerDMIndex) and other sensor details
Status: current Access: not-accessible
OBJECT-TYPE    
  PowerDMEntry  

powerDMIndex 1.3.6.1.4.1.17373.3.29.1.1
Table entry index value
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..100  

powerDMSerial 1.3.6.1.4.1.17373.3.29.1.2
Serial Number
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMName 1.3.6.1.4.1.17373.3.29.1.3
Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMAvail 1.3.6.1.4.1.17373.3.29.1.4
Is device currently plugged in?
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

powerDMUnitInfoTitle 1.3.6.1.4.1.17373.3.29.1.5
Type of Unit
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMUnitInfoVersion 1.3.6.1.4.1.17373.3.29.1.6
Unit Version Number
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMUnitInfoMainCount 1.3.6.1.4.1.17373.3.29.1.7
Number of Main (Total Amps) Channels on the Unit
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..16  

powerDMUnitInfoAuxCount 1.3.6.1.4.1.17373.3.29.1.8
Number of Auxiliary (Outlet) Channels on the Unit
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..48  

powerDMChannelName1 1.3.6.1.4.1.17373.3.29.1.9
Channel 1 Factory Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelName2 1.3.6.1.4.1.17373.3.29.1.10
Channel 2 Factory Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelName3 1.3.6.1.4.1.17373.3.29.1.11
Channel 3 Factory Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelName4 1.3.6.1.4.1.17373.3.29.1.12
Channel 4 Factory Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelName5 1.3.6.1.4.1.17373.3.29.1.13
Channel 5 Factory Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelName6 1.3.6.1.4.1.17373.3.29.1.14
Channel 6 Factory Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelName7 1.3.6.1.4.1.17373.3.29.1.15
Channel 7 Factory Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelName8 1.3.6.1.4.1.17373.3.29.1.16
Channel 8 Factory Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelName9 1.3.6.1.4.1.17373.3.29.1.17
Channel 9 Factory Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelName10 1.3.6.1.4.1.17373.3.29.1.18
Channel 10 Factory Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelName11 1.3.6.1.4.1.17373.3.29.1.19
Channel 11 Factory Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelName12 1.3.6.1.4.1.17373.3.29.1.20
Channel 12 Factory Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelName13 1.3.6.1.4.1.17373.3.29.1.21
Channel 13 Factory Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelName14 1.3.6.1.4.1.17373.3.29.1.22
Channel 14 Factory Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelName15 1.3.6.1.4.1.17373.3.29.1.23
Channel 15 Factory Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelName16 1.3.6.1.4.1.17373.3.29.1.24
Channel 16 Factory Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelName17 1.3.6.1.4.1.17373.3.29.1.25
Channel 17 Factory Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelName18 1.3.6.1.4.1.17373.3.29.1.26
Channel 18 Factory Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelName19 1.3.6.1.4.1.17373.3.29.1.27
Channel 19 Factory Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelName20 1.3.6.1.4.1.17373.3.29.1.28
Channel 20 Factory Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelName21 1.3.6.1.4.1.17373.3.29.1.29
Channel 21 Factory Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelName22 1.3.6.1.4.1.17373.3.29.1.30
Channel 22 Factory Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelName23 1.3.6.1.4.1.17373.3.29.1.31
Channel 23 Factory Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelName24 1.3.6.1.4.1.17373.3.29.1.32
Channel 24 Factory Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelName25 1.3.6.1.4.1.17373.3.29.1.33
Channel 25 Factory Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelName26 1.3.6.1.4.1.17373.3.29.1.34
Channel 26 Factory Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelName27 1.3.6.1.4.1.17373.3.29.1.35
Channel 27 Factory Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelName28 1.3.6.1.4.1.17373.3.29.1.36
Channel 28 Factory Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelName29 1.3.6.1.4.1.17373.3.29.1.37
Channel 29 Factory Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelName30 1.3.6.1.4.1.17373.3.29.1.38
Channel 30 Factory Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelName31 1.3.6.1.4.1.17373.3.29.1.39
Channel 31 Factory Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelName32 1.3.6.1.4.1.17373.3.29.1.40
Channel 32 Factory Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelName33 1.3.6.1.4.1.17373.3.29.1.41
Channel 33 Factory Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelName34 1.3.6.1.4.1.17373.3.29.1.42
Channel 34 Factory Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelName35 1.3.6.1.4.1.17373.3.29.1.43
Channel 35 Factory Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelName36 1.3.6.1.4.1.17373.3.29.1.44
Channel 36 Factory Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelName37 1.3.6.1.4.1.17373.3.29.1.45
Channel 37 Factory Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelName38 1.3.6.1.4.1.17373.3.29.1.46
Channel 38 Factory Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelName39 1.3.6.1.4.1.17373.3.29.1.47
Channel 39 Factory Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelName40 1.3.6.1.4.1.17373.3.29.1.48
Channel 40 Factory Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelName41 1.3.6.1.4.1.17373.3.29.1.49
Channel 41 Factory Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelName42 1.3.6.1.4.1.17373.3.29.1.50
Channel 42 Factory Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelName43 1.3.6.1.4.1.17373.3.29.1.51
Channel 43 Factory Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelName44 1.3.6.1.4.1.17373.3.29.1.52
Channel 44 Factory Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelName45 1.3.6.1.4.1.17373.3.29.1.53
Channel 45 Factory Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelName46 1.3.6.1.4.1.17373.3.29.1.54
Channel 46 Factory Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelName47 1.3.6.1.4.1.17373.3.29.1.55
Channel 47 Factory Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelName48 1.3.6.1.4.1.17373.3.29.1.56
Channel 48 Factory Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelFriendly1 1.3.6.1.4.1.17373.3.29.1.57
Channel 1 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelFriendly2 1.3.6.1.4.1.17373.3.29.1.58
Channel 2 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelFriendly3 1.3.6.1.4.1.17373.3.29.1.59
Channel 3 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelFriendly4 1.3.6.1.4.1.17373.3.29.1.60
Channel 4 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelFriendly5 1.3.6.1.4.1.17373.3.29.1.61
Channel 5 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelFriendly6 1.3.6.1.4.1.17373.3.29.1.62
Channel 6 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelFriendly7 1.3.6.1.4.1.17373.3.29.1.63
Channel 7 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelFriendly8 1.3.6.1.4.1.17373.3.29.1.64
Channel 8 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelFriendly9 1.3.6.1.4.1.17373.3.29.1.65
Channel 9 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelFriendly10 1.3.6.1.4.1.17373.3.29.1.66
Channel 10 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelFriendly11 1.3.6.1.4.1.17373.3.29.1.67
Channel 11 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelFriendly12 1.3.6.1.4.1.17373.3.29.1.68
Channel 12 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelFriendly13 1.3.6.1.4.1.17373.3.29.1.69
Channel 13 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelFriendly14 1.3.6.1.4.1.17373.3.29.1.70
Channel 14 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelFriendly15 1.3.6.1.4.1.17373.3.29.1.71
Channel 15 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelFriendly16 1.3.6.1.4.1.17373.3.29.1.72
Channel 16 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelFriendly17 1.3.6.1.4.1.17373.3.29.1.73
Channel 17 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelFriendly18 1.3.6.1.4.1.17373.3.29.1.74
Channel 18 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelFriendly19 1.3.6.1.4.1.17373.3.29.1.75
Channel 19 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelFriendly20 1.3.6.1.4.1.17373.3.29.1.76
Channel 20 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelFriendly21 1.3.6.1.4.1.17373.3.29.1.77
Channel 21 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelFriendly22 1.3.6.1.4.1.17373.3.29.1.78
Channel 22 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelFriendly23 1.3.6.1.4.1.17373.3.29.1.79
Channel 23 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelFriendly24 1.3.6.1.4.1.17373.3.29.1.80
Channel 24 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelFriendly25 1.3.6.1.4.1.17373.3.29.1.81
Channel 25 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelFriendly26 1.3.6.1.4.1.17373.3.29.1.82
Channel 26 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelFriendly27 1.3.6.1.4.1.17373.3.29.1.83
Channel 27 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelFriendly28 1.3.6.1.4.1.17373.3.29.1.84
Channel 28 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelFriendly29 1.3.6.1.4.1.17373.3.29.1.85
Channel 29 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelFriendly30 1.3.6.1.4.1.17373.3.29.1.86
Channel 30 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelFriendly31 1.3.6.1.4.1.17373.3.29.1.87
Channel 31 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelFriendly32 1.3.6.1.4.1.17373.3.29.1.88
Channel 32 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelFriendly33 1.3.6.1.4.1.17373.3.29.1.89
Channel 33 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelFriendly34 1.3.6.1.4.1.17373.3.29.1.90
Channel 34 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelFriendly35 1.3.6.1.4.1.17373.3.29.1.91
Channel 35 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelFriendly36 1.3.6.1.4.1.17373.3.29.1.92
Channel 36 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelFriendly37 1.3.6.1.4.1.17373.3.29.1.93
Channel 37 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelFriendly38 1.3.6.1.4.1.17373.3.29.1.94
Channel 38 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelFriendly39 1.3.6.1.4.1.17373.3.29.1.95
Channel 39 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelFriendly40 1.3.6.1.4.1.17373.3.29.1.96
Channel 40 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelFriendly41 1.3.6.1.4.1.17373.3.29.1.97
Channel 41 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelFriendly42 1.3.6.1.4.1.17373.3.29.1.98
Channel 42 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelFriendly43 1.3.6.1.4.1.17373.3.29.1.99
Channel 43 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelFriendly44 1.3.6.1.4.1.17373.3.29.1.100
Channel 44 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelFriendly45 1.3.6.1.4.1.17373.3.29.1.101
Channel 45 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelFriendly46 1.3.6.1.4.1.17373.3.29.1.102
Channel 46 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelFriendly47 1.3.6.1.4.1.17373.3.29.1.103
Channel 47 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelFriendly48 1.3.6.1.4.1.17373.3.29.1.104
Channel 48 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelGroup1 1.3.6.1.4.1.17373.3.29.1.105
Channel 1 Group
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelGroup2 1.3.6.1.4.1.17373.3.29.1.106
Channel 2 Group
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelGroup3 1.3.6.1.4.1.17373.3.29.1.107
Channel 3 Group
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelGroup4 1.3.6.1.4.1.17373.3.29.1.108
Channel 4 Group
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelGroup5 1.3.6.1.4.1.17373.3.29.1.109
Channel 5 Group
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelGroup6 1.3.6.1.4.1.17373.3.29.1.110
Channel 6 Group
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelGroup7 1.3.6.1.4.1.17373.3.29.1.111
Channel 7 Group
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelGroup8 1.3.6.1.4.1.17373.3.29.1.112
Channel 8 Group
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelGroup9 1.3.6.1.4.1.17373.3.29.1.113
Channel 9 Group
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelGroup10 1.3.6.1.4.1.17373.3.29.1.114
Channel 10 Group
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelGroup11 1.3.6.1.4.1.17373.3.29.1.115
Channel 11 Group
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelGroup12 1.3.6.1.4.1.17373.3.29.1.116
Channel 12 Group
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelGroup13 1.3.6.1.4.1.17373.3.29.1.117
Channel 13 Group
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelGroup14 1.3.6.1.4.1.17373.3.29.1.118
Channel 14 Group
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelGroup15 1.3.6.1.4.1.17373.3.29.1.119
Channel 15 Group
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelGroup16 1.3.6.1.4.1.17373.3.29.1.120
Channel 16 Group
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelGroup17 1.3.6.1.4.1.17373.3.29.1.121
Channel 17 Group
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelGroup18 1.3.6.1.4.1.17373.3.29.1.122
Channel 18 Group
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelGroup19 1.3.6.1.4.1.17373.3.29.1.123
Channel 19 Group
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelGroup20 1.3.6.1.4.1.17373.3.29.1.124
Channel 20 Group
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelGroup21 1.3.6.1.4.1.17373.3.29.1.125
Channel 21 Group
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelGroup22 1.3.6.1.4.1.17373.3.29.1.126
Channel 22 Group
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelGroup23 1.3.6.1.4.1.17373.3.29.1.127
Channel 23 Group
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelGroup24 1.3.6.1.4.1.17373.3.29.1.128
Channel 24 Group
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelGroup25 1.3.6.1.4.1.17373.3.29.1.129
Channel 25 Group
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelGroup26 1.3.6.1.4.1.17373.3.29.1.130
Channel 26 Group
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelGroup27 1.3.6.1.4.1.17373.3.29.1.131
Channel 27 Group
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelGroup28 1.3.6.1.4.1.17373.3.29.1.132
Channel 28 Group
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelGroup29 1.3.6.1.4.1.17373.3.29.1.133
Channel 29 Group
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelGroup30 1.3.6.1.4.1.17373.3.29.1.134
Channel 30 Group
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelGroup31 1.3.6.1.4.1.17373.3.29.1.135
Channel 31 Group
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelGroup32 1.3.6.1.4.1.17373.3.29.1.136
Channel 32 Group
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelGroup33 1.3.6.1.4.1.17373.3.29.1.137
Channel 33 Group
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelGroup34 1.3.6.1.4.1.17373.3.29.1.138
Channel 34 Group
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelGroup35 1.3.6.1.4.1.17373.3.29.1.139
Channel 35 Group
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelGroup36 1.3.6.1.4.1.17373.3.29.1.140
Channel 36 Group
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelGroup37 1.3.6.1.4.1.17373.3.29.1.141
Channel 37 Group
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelGroup38 1.3.6.1.4.1.17373.3.29.1.142
Channel 38 Group
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelGroup39 1.3.6.1.4.1.17373.3.29.1.143
Channel 39 Group
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelGroup40 1.3.6.1.4.1.17373.3.29.1.144
Channel 40 Group
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelGroup41 1.3.6.1.4.1.17373.3.29.1.145
Channel 41 Group
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelGroup42 1.3.6.1.4.1.17373.3.29.1.146
Channel 42 Group
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelGroup43 1.3.6.1.4.1.17373.3.29.1.147
Channel 43 Group
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelGroup44 1.3.6.1.4.1.17373.3.29.1.148
Channel 44 Group
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelGroup45 1.3.6.1.4.1.17373.3.29.1.149
Channel 45 Group
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelGroup46 1.3.6.1.4.1.17373.3.29.1.150
Channel 46 Group
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelGroup47 1.3.6.1.4.1.17373.3.29.1.151
Channel 47 Group
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMChannelGroup48 1.3.6.1.4.1.17373.3.29.1.152
Channel 48 Group
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

powerDMDeciAmps1 1.3.6.1.4.1.17373.3.29.1.153
Current in deciamps
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..1209  

powerDMDeciAmps2 1.3.6.1.4.1.17373.3.29.1.154
Current in deciamps
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..1209  

powerDMDeciAmps3 1.3.6.1.4.1.17373.3.29.1.155
Current in deciamps
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..1209  

powerDMDeciAmps4 1.3.6.1.4.1.17373.3.29.1.156
Current in deciamps
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..1209  

powerDMDeciAmps5 1.3.6.1.4.1.17373.3.29.1.157
Current in deciamps
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..1209  

powerDMDeciAmps6 1.3.6.1.4.1.17373.3.29.1.158
Current in deciamps
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..1209  

powerDMDeciAmps7 1.3.6.1.4.1.17373.3.29.1.159
Current in deciamps
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..1209  

powerDMDeciAmps8 1.3.6.1.4.1.17373.3.29.1.160
Current in deciamps
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..1209  

powerDMDeciAmps9 1.3.6.1.4.1.17373.3.29.1.161
Current in deciamps
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..1209  

powerDMDeciAmps10 1.3.6.1.4.1.17373.3.29.1.162
Current in deciamps
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..1209  

powerDMDeciAmps11 1.3.6.1.4.1.17373.3.29.1.163
Current in deciamps
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..1209  

powerDMDeciAmps12 1.3.6.1.4.1.17373.3.29.1.164
Current in deciamps
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..1209  

powerDMDeciAmps13 1.3.6.1.4.1.17373.3.29.1.165
Current in deciamps
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..1209  

powerDMDeciAmps14 1.3.6.1.4.1.17373.3.29.1.166
Current in deciamps
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..1209  

powerDMDeciAmps15 1.3.6.1.4.1.17373.3.29.1.167
Current in deciamps
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..1209  

powerDMDeciAmps16 1.3.6.1.4.1.17373.3.29.1.168
Current in deciamps
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..1209  

powerDMDeciAmps17 1.3.6.1.4.1.17373.3.29.1.169
Current in deciamps
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..1209  

powerDMDeciAmps18 1.3.6.1.4.1.17373.3.29.1.170
Current in deciamps
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..1209  

powerDMDeciAmps19 1.3.6.1.4.1.17373.3.29.1.171
Current in deciamps
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..1209  

powerDMDeciAmps20 1.3.6.1.4.1.17373.3.29.1.172
Current in deciamps
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..1209  

powerDMDeciAmps21 1.3.6.1.4.1.17373.3.29.1.173
Current in deciamps
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..1209  

powerDMDeciAmps22 1.3.6.1.4.1.17373.3.29.1.174
Current in deciamps
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..1209  

powerDMDeciAmps23 1.3.6.1.4.1.17373.3.29.1.175
Current in deciamps
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..1209  

powerDMDeciAmps24 1.3.6.1.4.1.17373.3.29.1.176
Current in deciamps
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..1209  

powerDMDeciAmps25 1.3.6.1.4.1.17373.3.29.1.177
Current in deciamps
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..1209  

powerDMDeciAmps26 1.3.6.1.4.1.17373.3.29.1.178
Current in deciamps
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..1209  

powerDMDeciAmps27 1.3.6.1.4.1.17373.3.29.1.179
Current in deciamps
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..1209  

powerDMDeciAmps28 1.3.6.1.4.1.17373.3.29.1.180
Current in deciamps
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..1209  

powerDMDeciAmps29 1.3.6.1.4.1.17373.3.29.1.181
Current in deciamps
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..1209  

powerDMDeciAmps30 1.3.6.1.4.1.17373.3.29.1.182
Current in deciamps
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..1209  

powerDMDeciAmps31 1.3.6.1.4.1.17373.3.29.1.183
Current in deciamps
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..1209  

powerDMDeciAmps32 1.3.6.1.4.1.17373.3.29.1.184
Current in deciamps
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..1209  

powerDMDeciAmps33 1.3.6.1.4.1.17373.3.29.1.185
Current in deciamps
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..1209  

powerDMDeciAmps34 1.3.6.1.4.1.17373.3.29.1.186
Current in deciamps
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..1209  

powerDMDeciAmps35 1.3.6.1.4.1.17373.3.29.1.187
Current in deciamps
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..1209  

powerDMDeciAmps36 1.3.6.1.4.1.17373.3.29.1.188
Current in deciamps
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..1209  

powerDMDeciAmps37 1.3.6.1.4.1.17373.3.29.1.189
Current in deciamps
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..1209  

powerDMDeciAmps38 1.3.6.1.4.1.17373.3.29.1.190
Current in deciamps
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..1209  

powerDMDeciAmps39 1.3.6.1.4.1.17373.3.29.1.191
Current in deciamps
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..1209  

powerDMDeciAmps40 1.3.6.1.4.1.17373.3.29.1.192
Current in deciamps
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..1209  

powerDMDeciAmps41 1.3.6.1.4.1.17373.3.29.1.193
Current in deciamps
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..1209  

powerDMDeciAmps42 1.3.6.1.4.1.17373.3.29.1.194
Current in deciamps
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..1209  

powerDMDeciAmps43 1.3.6.1.4.1.17373.3.29.1.195
Current in deciamps
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..1209  

powerDMDeciAmps44 1.3.6.1.4.1.17373.3.29.1.196
Current in deciamps
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..1209  

powerDMDeciAmps45 1.3.6.1.4.1.17373.3.29.1.197
Current in deciamps
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..1209  

powerDMDeciAmps46 1.3.6.1.4.1.17373.3.29.1.198
Current in deciamps
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..1209  

powerDMDeciAmps47 1.3.6.1.4.1.17373.3.29.1.199
Current in deciamps
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..1209  

powerDMDeciAmps48 1.3.6.1.4.1.17373.3.29.1.200
Current in deciamps
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..1209  

ioExpanderEntry 1.3.6.1.4.1.17373.3.30.1
Entry in the IO Expander table: each entry contains an index (ioExpanderIndex) and other details
Status: current Access: not-accessible
OBJECT-TYPE    
  IoExpanderEntry  

ioExpanderIndex 1.3.6.1.4.1.17373.3.30.1.1
Table entry index value
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..1  

ioExpanderSerial 1.3.6.1.4.1.17373.3.30.1.2
Serial Number
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

ioExpanderName 1.3.6.1.4.1.17373.3.30.1.3
Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

ioExpanderAvail 1.3.6.1.4.1.17373.3.30.1.4
Is device currently plugged in?
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ioExpanderFriendlyName1 1.3.6.1.4.1.17373.3.30.1.5
IO 1 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

ioExpanderFriendlyName2 1.3.6.1.4.1.17373.3.30.1.6
IO 2 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

ioExpanderFriendlyName3 1.3.6.1.4.1.17373.3.30.1.7
IO 3 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

ioExpanderFriendlyName4 1.3.6.1.4.1.17373.3.30.1.8
IO 4 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

ioExpanderFriendlyName5 1.3.6.1.4.1.17373.3.30.1.9
IO 5 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

ioExpanderFriendlyName6 1.3.6.1.4.1.17373.3.30.1.10
IO 6 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

ioExpanderFriendlyName7 1.3.6.1.4.1.17373.3.30.1.11
IO 7 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

ioExpanderFriendlyName8 1.3.6.1.4.1.17373.3.30.1.12
IO 8 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

ioExpanderFriendlyName9 1.3.6.1.4.1.17373.3.30.1.13
IO 9 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

ioExpanderFriendlyName10 1.3.6.1.4.1.17373.3.30.1.14
IO 10 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

ioExpanderFriendlyName11 1.3.6.1.4.1.17373.3.30.1.15
IO 11 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

ioExpanderFriendlyName12 1.3.6.1.4.1.17373.3.30.1.16
IO 12 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

ioExpanderFriendlyName13 1.3.6.1.4.1.17373.3.30.1.17
IO 13 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

ioExpanderFriendlyName14 1.3.6.1.4.1.17373.3.30.1.18
IO 14 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

ioExpanderFriendlyName15 1.3.6.1.4.1.17373.3.30.1.19
IO 15 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

ioExpanderFriendlyName16 1.3.6.1.4.1.17373.3.30.1.20
IO 16 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

ioExpanderFriendlyName17 1.3.6.1.4.1.17373.3.30.1.21
IO 17 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

ioExpanderFriendlyName18 1.3.6.1.4.1.17373.3.30.1.22
IO 18 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

ioExpanderFriendlyName19 1.3.6.1.4.1.17373.3.30.1.23
IO 19 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

ioExpanderFriendlyName20 1.3.6.1.4.1.17373.3.30.1.24
IO 20 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

ioExpanderFriendlyName21 1.3.6.1.4.1.17373.3.30.1.25
IO 21 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

ioExpanderFriendlyName22 1.3.6.1.4.1.17373.3.30.1.26
IO 22 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

ioExpanderFriendlyName23 1.3.6.1.4.1.17373.3.30.1.27
IO 23 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

ioExpanderFriendlyName24 1.3.6.1.4.1.17373.3.30.1.28
IO 24 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

ioExpanderFriendlyName25 1.3.6.1.4.1.17373.3.30.1.29
IO 25 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

ioExpanderFriendlyName26 1.3.6.1.4.1.17373.3.30.1.30
IO 26 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

ioExpanderFriendlyName27 1.3.6.1.4.1.17373.3.30.1.31
IO 27 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

ioExpanderFriendlyName28 1.3.6.1.4.1.17373.3.30.1.32
IO 28 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

ioExpanderFriendlyName29 1.3.6.1.4.1.17373.3.30.1.33
IO 29 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

ioExpanderFriendlyName30 1.3.6.1.4.1.17373.3.30.1.34
IO 30 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

ioExpanderFriendlyName31 1.3.6.1.4.1.17373.3.30.1.35
IO 31 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

ioExpanderFriendlyName32 1.3.6.1.4.1.17373.3.30.1.36
IO 32 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

ioExpanderIO1 1.3.6.1.4.1.17373.3.30.1.37
Current reading for Analog Input 1
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

ioExpanderIO2 1.3.6.1.4.1.17373.3.30.1.38
Current reading for Analog Input 2
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

ioExpanderIO3 1.3.6.1.4.1.17373.3.30.1.39
Current reading for Analog Input 3
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

ioExpanderIO4 1.3.6.1.4.1.17373.3.30.1.40
Current reading for Analog Input 4
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

ioExpanderIO5 1.3.6.1.4.1.17373.3.30.1.41
Current reading for Analog Input 5
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

ioExpanderIO6 1.3.6.1.4.1.17373.3.30.1.42
Current reading for Analog Input 6
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

ioExpanderIO7 1.3.6.1.4.1.17373.3.30.1.43
Current reading for Analog Input 7
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

ioExpanderIO8 1.3.6.1.4.1.17373.3.30.1.44
Current reading for Analog Input 8
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

ioExpanderIO9 1.3.6.1.4.1.17373.3.30.1.45
Current reading for Analog Input 9
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

ioExpanderIO10 1.3.6.1.4.1.17373.3.30.1.46
Current reading for Analog Input 10
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

ioExpanderIO11 1.3.6.1.4.1.17373.3.30.1.47
Current reading for Analog Input 11
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

ioExpanderIO12 1.3.6.1.4.1.17373.3.30.1.48
Current reading for Analog Input 12
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

ioExpanderIO13 1.3.6.1.4.1.17373.3.30.1.49
Current reading for Analog Input 13
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

ioExpanderIO14 1.3.6.1.4.1.17373.3.30.1.50
Current reading for Analog Input 14
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

ioExpanderIO15 1.3.6.1.4.1.17373.3.30.1.51
Current reading for Analog Input 15
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

ioExpanderIO16 1.3.6.1.4.1.17373.3.30.1.52
Current reading for Analog Input 16
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

ioExpanderIO17 1.3.6.1.4.1.17373.3.30.1.53
Current reading for Analog Input 17
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

ioExpanderIO18 1.3.6.1.4.1.17373.3.30.1.54
Current reading for Analog Input 18
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

ioExpanderIO19 1.3.6.1.4.1.17373.3.30.1.55
Current reading for Analog Input 19
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

ioExpanderIO20 1.3.6.1.4.1.17373.3.30.1.56
Current reading for Analog Input 20
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

ioExpanderIO21 1.3.6.1.4.1.17373.3.30.1.57
Current reading for Analog Input 21
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

ioExpanderIO22 1.3.6.1.4.1.17373.3.30.1.58
Current reading for Analog Input 22
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

ioExpanderIO23 1.3.6.1.4.1.17373.3.30.1.59
Current reading for Analog Input 23
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

ioExpanderIO24 1.3.6.1.4.1.17373.3.30.1.60
Current reading for Analog Input 24
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

ioExpanderIO25 1.3.6.1.4.1.17373.3.30.1.61
Current reading for Analog Input 25
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

ioExpanderIO26 1.3.6.1.4.1.17373.3.30.1.62
Current reading for Analog Input 26
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

ioExpanderIO27 1.3.6.1.4.1.17373.3.30.1.63
Current reading for Analog Input 27
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

ioExpanderIO28 1.3.6.1.4.1.17373.3.30.1.64
Current reading for Analog Input 28
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

ioExpanderIO29 1.3.6.1.4.1.17373.3.30.1.65
Current reading for Analog Input 29
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

ioExpanderIO30 1.3.6.1.4.1.17373.3.30.1.66
Current reading for Analog Input 30
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

ioExpanderIO31 1.3.6.1.4.1.17373.3.30.1.67
Current reading for Analog Input 31
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

ioExpanderIO32 1.3.6.1.4.1.17373.3.30.1.68
Current reading for Analog Input 32
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

ioExpanderRelayName1 1.3.6.1.4.1.17373.3.30.1.69
Relay1 Friendly Name
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

ioExpanderRelayState1 1.3.6.1.4.1.17373.3.30.1.70
Relay1 Current Status: 0 = Off, 1 = On
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ioExpanderRelayLatchingMode1 1.3.6.1.4.1.17373.3.30.1.71
Relay1 Latching mode: 0 = Non-latching, 1 = Latching
Status: current Access: read-write
OBJECT-TYPE    
  Gauge32  

ioExpanderRelayOverride1 1.3.6.1.4.1.17373.3.30.1.72
Relay1 Override Mode: 0 - None, 1 - On, 2 - Off
Status: current Access: read-write
OBJECT-TYPE    
  Gauge32  

ioExpanderRelayAcknowledge1 1.3.6.1.4.1.17373.3.30.1.73
Relay1 Acknowledge write a 1, always reads back 0
Status: current Access: read-write
OBJECT-TYPE    
  Gauge32  

ioExpanderRelayName2 1.3.6.1.4.1.17373.3.30.1.74
Relay2 Friendly Name
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

ioExpanderRelayState2 1.3.6.1.4.1.17373.3.30.1.75
Relay2 Current Status: 0 = Off, 1 = On
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ioExpanderRelayLatchingMode2 1.3.6.1.4.1.17373.3.30.1.76
Relay2 Latching mode: 0 = Non-latching, 1 = Latching
Status: current Access: read-write
OBJECT-TYPE    
  Gauge32  

ioExpanderRelayOverride2 1.3.6.1.4.1.17373.3.30.1.77
Relay2 Override Mode: 0 - None, 1 - On, 2 - Off
Status: current Access: read-write
OBJECT-TYPE    
  Gauge32  

ioExpanderRelayAcknowledge2 1.3.6.1.4.1.17373.3.30.1.78
Relay2 Acknowledge write a 1, always reads back 0
Status: current Access: read-write
OBJECT-TYPE    
  Gauge32  

ioExpanderRelayName3 1.3.6.1.4.1.17373.3.30.1.79
Relay3 Friendly Name
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

ioExpanderRelayState3 1.3.6.1.4.1.17373.3.30.1.80
Relay3 Current Status: 0 = Off, 1 = On
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ioExpanderRelayLatchingMode3 1.3.6.1.4.1.17373.3.30.1.81
Relay3 Latching mode: 0 = Non-latching, 1 = Latching
Status: current Access: read-write
OBJECT-TYPE    
  Gauge32  

ioExpanderRelayOverride3 1.3.6.1.4.1.17373.3.30.1.82
Relay3 Override Mode: 0 - None, 1 - On, 2 - Off
Status: current Access: read-write
OBJECT-TYPE    
  Gauge32  

ioExpanderRelayAcknowledge3 1.3.6.1.4.1.17373.3.30.1.83
Relay3 Acknowledge write a 1, always reads back 0
Status: current Access: read-write
OBJECT-TYPE    
  Gauge32  

t3hdSensorEntry 1.3.6.1.4.1.17373.3.31.1
Entry in the T3HD sensor table: each entry contains an index (t3hdIndex) and other sensor details
Status: current Access: not-accessible
OBJECT-TYPE    
  T3hdSensorEntry  

t3hdSensorIndex 1.3.6.1.4.1.17373.3.31.1.1
Table entry index value
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..100  

t3hdSensorSerial 1.3.6.1.4.1.17373.3.31.1.2
Serial Number
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

t3hdSensorName 1.3.6.1.4.1.17373.3.31.1.3
Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

t3hdSensorAvail 1.3.6.1.4.1.17373.3.31.1.4
Is device currently plugged in?
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

t3hdSensorIntName 1.3.6.1.4.1.17373.3.31.1.5
Internal Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

t3hdSensorIntTempC 1.3.6.1.4.1.17373.3.31.1.6
Internal Temperature reading in C
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER -50..100  

t3hdSensorIntTempF 1.3.6.1.4.1.17373.3.31.1.7
Internal Temperature reading in F
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER -58..212  

t3hdSensorIntHumidity 1.3.6.1.4.1.17373.3.31.1.8
Internal Humidity reading
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

t3hdSensorIntDewPointC 1.3.6.1.4.1.17373.3.31.1.9
Internal Dew Point reading in C
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER -50..100  

t3hdSensorIntDewPointF 1.3.6.1.4.1.17373.3.31.1.10
Internal Dew Point reading in F
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER -58..212  

t3hdSensorExt1Avail 1.3.6.1.4.1.17373.3.31.1.11
External 1 status: 0 = unplugged, 1 = normal operation, 2 = device error
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

t3hdSensorExt1Name 1.3.6.1.4.1.17373.3.31.1.12
External 1 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

t3hdSensorExt1TempC 1.3.6.1.4.1.17373.3.31.1.13
External 1 Temperature reading in C
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER -50..100  

t3hdSensorExt1TempF 1.3.6.1.4.1.17373.3.31.1.14
External 1 Temperature reading in F
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER -58..212  

t3hdSensorExt2Avail 1.3.6.1.4.1.17373.3.31.1.15
External 2 status: 0 = unplugged, 1 = normal operation, 2 = device error
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

t3hdSensorExt2Name 1.3.6.1.4.1.17373.3.31.1.16
External 2 Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

t3hdSensorExt2TempC 1.3.6.1.4.1.17373.3.31.1.17
External 2 Temperature reading in C
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER -50..100  

t3hdSensorExt2TempF 1.3.6.1.4.1.17373.3.31.1.18
External 2 Temperature reading in F
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER -58..212  

thdSensorEntry 1.3.6.1.4.1.17373.3.32.1
Entry in the THD sensor table: each entry contains an index (thdIndex) and other sensor details
Status: current Access: not-accessible
OBJECT-TYPE    
  ThdSensorEntry  

thdSensorIndex 1.3.6.1.4.1.17373.3.32.1.1
Table entry index value
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..100  

thdSensorSerial 1.3.6.1.4.1.17373.3.32.1.2
Serial Number
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

thdSensorName 1.3.6.1.4.1.17373.3.32.1.3
Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

thdSensorAvail 1.3.6.1.4.1.17373.3.32.1.4
Is device currently plugged in?
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

thdSensorTempC 1.3.6.1.4.1.17373.3.32.1.5
Temperature reading in C
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER -50..100  

thdSensorTempF 1.3.6.1.4.1.17373.3.32.1.6
Temperature reading in F
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER -58..212  

thdSensorHumidity 1.3.6.1.4.1.17373.3.32.1.7
Humidity reading
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

thdSensorDewPointC 1.3.6.1.4.1.17373.3.32.1.8
Dew Point reading in C
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER -50..100  

thdSensorDewPointF 1.3.6.1.4.1.17373.3.32.1.9
Dew Point reading in F
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER -58..212  

pos60VdcSensorEntry 1.3.6.1.4.1.17373.3.33.1
Entry in the 60Vdc sensor table: each entry contains an index (pos60VdcSensorIndex) and other sensor details
Status: current Access: not-accessible
OBJECT-TYPE    
  Pos60VdcSensorEntry  

pos60VdcSensorIndex 1.3.6.1.4.1.17373.3.33.1.1
Table entry index value
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..100  

pos60VdcSensorSerial 1.3.6.1.4.1.17373.3.33.1.2
Serial Number
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

pos60VdcSensorName 1.3.6.1.4.1.17373.3.33.1.3
Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

pos60VdcSensorAvail 1.3.6.1.4.1.17373.3.33.1.4
Is device currently plugged in?
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

pos60VdcSensorVoltage 1.3.6.1.4.1.17373.3.33.1.5
60Vdc Sensor value
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER -10..100  

ctrl2CirTotEntry 1.3.6.1.4.1.17373.3.34.1
Entry in the 3 phase outlet control table: each entry contains an index (ctrl2CirTotIndex) and other outlet control monitoring details
Status: current Access: not-accessible
OBJECT-TYPE    
  Ctrl2CirTotEntry  

ctrl2CirTotIndex 1.3.6.1.4.1.17373.3.34.1.1
Table entry index value
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..100  

ctrl2CirTotSerial 1.3.6.1.4.1.17373.3.34.1.2
Serial Number
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

ctrl2CirTotName 1.3.6.1.4.1.17373.3.34.1.3
Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

ctrl2CirTotAvail 1.3.6.1.4.1.17373.3.34.1.4
Is device currently plugged in?
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl2CirTotkWattHrsTot 1.3.6.1.4.1.17373.3.34.1.5
Current Reading for kWatt-Hours (Total)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl2CirTotVoltsTot 1.3.6.1.4.1.17373.3.34.1.6
Current reading for Volts (Total)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl2CirTotVoltPeakTot 1.3.6.1.4.1.17373.3.34.1.7
Current reading for Peak-Volts (Total)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl2CirTotDeciAmpsTot 1.3.6.1.4.1.17373.3.34.1.8
Current reading for DeciAmps (Total)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl2CirTotDeciAmpsPeakTot 1.3.6.1.4.1.17373.3.34.1.9
Current reading for Peak-DeciAmps (Total)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl2CirTotRealPowerTot 1.3.6.1.4.1.17373.3.34.1.10
Current reading for Real Power (Total)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl2CirTotApparentPowerTot 1.3.6.1.4.1.17373.3.34.1.11
Current reading for Apparent Power (Total)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl2CirTotPowerFactorTot 1.3.6.1.4.1.17373.3.34.1.12
Current reading for Power Factor (Total)
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

ctrl2CirTotkWattHrsA 1.3.6.1.4.1.17373.3.34.1.13
Current Reading for kWatt-Hours (Phase A)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl2CirTotVoltsA 1.3.6.1.4.1.17373.3.34.1.14
Current reading for Volts (Phase A)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl2CirTotVoltPeakA 1.3.6.1.4.1.17373.3.34.1.15
Current reading for Peak-Volts (Phase A)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl2CirTotDeciAmpsA 1.3.6.1.4.1.17373.3.34.1.16
Current reading for DeciAmps (Phase A)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl2CirTotDeciAmpsPeakA 1.3.6.1.4.1.17373.3.34.1.17
Current reading for Peak-DeciAmps (Phase A)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl2CirTotRealPowerA 1.3.6.1.4.1.17373.3.34.1.18
Current reading for Real Power (Phase A)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl2CirTotApparentPowerA 1.3.6.1.4.1.17373.3.34.1.19
Current reading for Apparent Power (Phase A)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl2CirTotPowerFactorA 1.3.6.1.4.1.17373.3.34.1.20
Current reading for Power Factor (Phase A)
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

ctrl2CirTotkWattHrsB 1.3.6.1.4.1.17373.3.34.1.21
Current Reading for kWatt-Hours (Phase B)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl2CirTotVoltsB 1.3.6.1.4.1.17373.3.34.1.22
Current reading for Volts (Phase B)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl2CirTotVoltPeakB 1.3.6.1.4.1.17373.3.34.1.23
Current reading for Peak-Volts (Phase B)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl2CirTotDeciAmpsB 1.3.6.1.4.1.17373.3.34.1.24
Current reading for DeciAmps (Phase B)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl2CirTotDeciAmpsPeakB 1.3.6.1.4.1.17373.3.34.1.25
Current reading for Peak-DeciAmps (Phase B)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl2CirTotRealPowerB 1.3.6.1.4.1.17373.3.34.1.26
Current reading for Real Power (Phase B)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl2CirTotApparentPowerB 1.3.6.1.4.1.17373.3.34.1.27
Current reading for Apparent Power (Phase B)
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

ctrl2CirTotPowerFactorB 1.3.6.1.4.1.17373.3.34.1.28
Current reading for Power Factor (Phase B)
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

sc10Entry 1.3.6.1.4.1.17373.3.35.1
Entry in the sc10 table: each entry contains an index (sc10Index) and other details
Status: current Access: not-accessible
OBJECT-TYPE    
  Sc10Entry  

sc10Index 1.3.6.1.4.1.17373.3.35.1.1
Table entry index value
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..1  

sc10Serial 1.3.6.1.4.1.17373.3.35.1.2
Serial Number
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

sc10Name 1.3.6.1.4.1.17373.3.35.1.3
Friendly Name
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

sc10Avail 1.3.6.1.4.1.17373.3.35.1.4
Is device currently plugged in?
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

sc10ControlMode 1.3.6.1.4.1.17373.3.35.1.5
Control Mode setting indicator
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER setpoint(0), capacity(1)  

sc10SetpointC 1.3.6.1.4.1.17373.3.35.1.6
Current temperature set point in C
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

sc10SetpointF 1.3.6.1.4.1.17373.3.35.1.7
Current temperature set point in F
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 32..212  

sc10TempC 1.3.6.1.4.1.17373.3.35.1.8
Current internal temperature reading in C
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

sc10TempF 1.3.6.1.4.1.17373.3.35.1.9
Current internal temperature reading in F
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 32..212  

sc10Capacity 1.3.6.1.4.1.17373.3.35.1.10
Current capacity for Fan Speed
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

alarmSystem 1.3.6.1.4.1.17373.3.101
OBJECT IDENTIFIER    

alarmCfgTable 1.3.6.1.4.1.17373.3.101.1
Provides access for alarm configuration. Each row represents an alarm.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AlarmCfgEntry

alarmCfgEntry 1.3.6.1.4.1.17373.3.101.1.1
Entry in the alarm cfg table: each entry contains an index (alarmCfgIndex) and other details
Status: current Access: not-accessible
OBJECT-TYPE    
  AlarmCfgEntry  

alarmCfgIndex 1.3.6.1.4.1.17373.3.101.1.1.1
Table entry index value. Provides unique ID for alarm, numbered from 1 to 200
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..200  

alarmCfgReadingID 1.3.6.1.4.1.17373.3.101.1.1.2
OID of a particular measurement to monitor. This object is also used to create or delete a row. To create a new row, set the Sensor ID on a row that doesn't exist. Set the ReadingID to 0.0 to destroy a row.
Status: current Access: read-create
OBJECT-TYPE    
  OBJECT IDENTIFIER  

alarmCfgThreshold 1.3.6.1.4.1.17373.3.101.1.1.3
Depending on TripSelect this value acts as an upper or lower boundary for the sensor value. The value is in units of tenths. SNMP Threshold = Actual Value * 10 Example: 45 Threshold = 4.5 Amps
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

alarmCfgTripSelect 1.3.6.1.4.1.17373.3.101.1.1.4
Tells if alarm trips above or below the threshold value
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER tripBelow(0), tripAbove(1)  

cmTrap 1.3.6.1.4.1.17373.3.32767
OBJECT IDENTIFIER    

cmTrapPrefix 1.3.6.1.4.1.17373.3.32767.0
OBJECT IDENTIFIER    

cmTestNOTIFY 1.3.6.1.4.1.17373.3.32767.0.10101
Test SNMP Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmClimateTempCNOTIFY 1.3.6.1.4.1.17373.3.32767.0.10205
Climate Temperature Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmClimateTempFNOTIFY 1.3.6.1.4.1.17373.3.32767.0.10206
Climate Temperature Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmClimateHumidityNOTIFY 1.3.6.1.4.1.17373.3.32767.0.10207
Climate Humidity Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmClimateLightNOTIFY 1.3.6.1.4.1.17373.3.32767.0.10208
Climate Light Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmClimateAirflowNOTIFY 1.3.6.1.4.1.17373.3.32767.0.10209
Climate Air Flow Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmClimateSoundNOTIFY 1.3.6.1.4.1.17373.3.32767.0.10210
Climate Sound Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmClimateIO1NOTIFY 1.3.6.1.4.1.17373.3.32767.0.10211
Climate IO1 Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmClimateIO2NOTIFY 1.3.6.1.4.1.17373.3.32767.0.10212
Climate IO2 Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmClimateIO3NOTIFY 1.3.6.1.4.1.17373.3.32767.0.10213
Climate IO3 Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmClimateDewPointCNOTIFY 1.3.6.1.4.1.17373.3.32767.0.10214
Climate Dew Point Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmClimateDewPointFNOTIFY 1.3.6.1.4.1.17373.3.32767.0.10215
Climate Dew Point Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowMonkWattHrsNOTIFY 1.3.6.1.4.1.17373.3.32767.0.10305
Kilo Watt Hours Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowMonVoltsNOTIFY 1.3.6.1.4.1.17373.3.32767.0.10306
Volts Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowMonVoltMaxNOTIFY 1.3.6.1.4.1.17373.3.32767.0.10307
Volts Max Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowMonVoltMinNOTIFY 1.3.6.1.4.1.17373.3.32767.0.10308
Volts Min Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowMonVoltPeakNOTIFY 1.3.6.1.4.1.17373.3.32767.0.10309
Volt Peak Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowMonDeciAmpsNOTIFY 1.3.6.1.4.1.17373.3.32767.0.10310
DeciAmps Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowMonRealPowerNOTIFY 1.3.6.1.4.1.17373.3.32767.0.10311
Real Power Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowMonApparentPowerNOTIFY 1.3.6.1.4.1.17373.3.32767.0.10312
Apparent Power Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowMonPowerFactorNOTIFY 1.3.6.1.4.1.17373.3.32767.0.10313
Power Factor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowMonOutlet1NOTIFY 1.3.6.1.4.1.17373.3.32767.0.10314
Outlet 1 Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowMonOutlet2NOTIFY 1.3.6.1.4.1.17373.3.32767.0.10315
Outlet 2 Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowMonOutlet1StatusTimeNOTIFY 1.3.6.1.4.1.17373.3.32767.0.10316
Outlet1StatusTime Trip Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowMonOutlet2StatusTimeNOTIFY 1.3.6.1.4.1.17373.3.32767.0.10317
Outlet2StatusTime Trip Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmTempSensorTempCNOTIFY 1.3.6.1.4.1.17373.3.32767.0.10405
Remote Temp Sensor - Temperature Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmTempSensorTempFNOTIFY 1.3.6.1.4.1.17373.3.32767.0.10406
Remote Temp Sensor - Temperature Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmAirFlowSensorTempCNOTIFY 1.3.6.1.4.1.17373.3.32767.0.10505
Remote Air Flow Sensor - Temperature Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmAirFlowSensorTempFNOTIFY 1.3.6.1.4.1.17373.3.32767.0.10506
Remote Air Flow Sensor - Temperature Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmAirFlowSensorFlowNOTIFY 1.3.6.1.4.1.17373.3.32767.0.10507
Remote Air Flow Sensor - Air Flow Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmAirFlowSensorHumidityNOTIFY 1.3.6.1.4.1.17373.3.32767.0.10508
Remote Air Flow Sensor - Humidity
Status: current Access: read-create
NOTIFICATION-TYPE    

cmAirFlowSensorDewPointCNOTIFY 1.3.6.1.4.1.17373.3.32767.0.10509
Remote Air Flow Sensor - Dew Point Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmAirFlowSensorDewPointFNOTIFY 1.3.6.1.4.1.17373.3.32767.0.10510
Remote Air Flow Sensor - Dew Point Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChDELTADeciAmpsANOTIFY 1.3.6.1.4.1.17373.3.32767.0.10606
Deciamps A Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChDELTADeciAmpsBNOTIFY 1.3.6.1.4.1.17373.3.32767.0.10607
Deciamps B Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChDELTADeciAmpsCNOTIFY 1.3.6.1.4.1.17373.3.32767.0.10608
Deciamps C Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChDELTAkWattHrsTotalNOTIFY 1.3.6.1.4.1.17373.3.32767.0.10609
Kilo Watt Hours Total Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChDELTARealPowerTotalNOTIFY 1.3.6.1.4.1.17373.3.32767.0.10610
Watts Total Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChDELTAkWattHrsABNOTIFY 1.3.6.1.4.1.17373.3.32767.0.10611
Kilo Watt Hours A Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChDELTAVoltsABNOTIFY 1.3.6.1.4.1.17373.3.32767.0.10612
Volts AB Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChDELTAVoltPeakABNOTIFY 1.3.6.1.4.1.17373.3.32767.0.10613
Volts Peak AB Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChDELTARealPowerABNOTIFY 1.3.6.1.4.1.17373.3.32767.0.10614
Real Power AB Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChDELTAApparentPowerABNOTIFY 1.3.6.1.4.1.17373.3.32767.0.10615
VoltAmps AB Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChDELTAPowerFactorABNOTIFY 1.3.6.1.4.1.17373.3.32767.0.10616
Power Factor AB Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChDELTAkWattHrsBCNOTIFY 1.3.6.1.4.1.17373.3.32767.0.10617
Kilo Watt Hours BC Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChDELTAVoltsBCNOTIFY 1.3.6.1.4.1.17373.3.32767.0.10618
Volts BC Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChDELTAVoltPeakBCNOTIFY 1.3.6.1.4.1.17373.3.32767.0.10619
Volts Peak BC Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChDELTARealPowerBCNOTIFY 1.3.6.1.4.1.17373.3.32767.0.10620
Real Power BC Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChDELTAApparentPowerBCNOTIFY 1.3.6.1.4.1.17373.3.32767.0.10621
VoltAmps BC Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChDELTAPowerFactorBCNOTIFY 1.3.6.1.4.1.17373.3.32767.0.10622
Power Factor BC Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChDELTAkWattHrsCANOTIFY 1.3.6.1.4.1.17373.3.32767.0.10623
Kilo Watt Hours CA Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChDELTAVoltsCANOTIFY 1.3.6.1.4.1.17373.3.32767.0.10624
Volts CA Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChDELTAVoltPeakCANOTIFY 1.3.6.1.4.1.17373.3.32767.0.10625
Volts Peak CA Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChDELTARealPowerCANOTIFY 1.3.6.1.4.1.17373.3.32767.0.10626
Real Power CA Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChDELTAApparentPowerCANOTIFY 1.3.6.1.4.1.17373.3.32767.0.10627
VoltAmps CA Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChDELTAPowerFactorCANOTIFY 1.3.6.1.4.1.17373.3.32767.0.10628
Power Factor CA Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmDoorSensorStatusNOTIFY 1.3.6.1.4.1.17373.3.32767.0.10705
Door sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmWaterSensorDampnessNOTIFY 1.3.6.1.4.1.17373.3.32767.0.10805
Water sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCurrentMonitorDeciAmpsNOTIFY 1.3.6.1.4.1.17373.3.32767.0.10905
Current Monitor Amps Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmMillivoltMonitorMVNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11005
Millivolt Monitor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPow3ChkWattHrsANOTIFY 1.3.6.1.4.1.17373.3.32767.0.11105
Kilo Watt Hours A Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPow3ChVoltsANOTIFY 1.3.6.1.4.1.17373.3.32767.0.11106
Volts A Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPow3ChVoltMaxANOTIFY 1.3.6.1.4.1.17373.3.32767.0.11107
Volts Max A Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPow3ChVoltMinANOTIFY 1.3.6.1.4.1.17373.3.32767.0.11108
Volts Min A Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPow3ChVoltPeakANOTIFY 1.3.6.1.4.1.17373.3.32767.0.11109
Volt Peak A Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPow3ChDeciAmpsANOTIFY 1.3.6.1.4.1.17373.3.32767.0.11110
Deciamps A Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPow3ChRealPowerANOTIFY 1.3.6.1.4.1.17373.3.32767.0.11111
Real Power A Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPow3ChApparentPowerANOTIFY 1.3.6.1.4.1.17373.3.32767.0.11112
Apparent Power A Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPow3ChPowerFactorANOTIFY 1.3.6.1.4.1.17373.3.32767.0.11113
Power Factor A Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPow3ChkWattHrsBNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11114
Kilo Watt Hours B Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPow3ChVoltsBNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11115
Volts B Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPow3ChVoltMaxBNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11116
Volts Max B Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPow3ChVoltMinBNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11117
Volts Min B Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPow3ChVoltPeakBNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11118
Volt Peak B Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPow3ChDeciAmpsBNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11119
Deciamps B Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPow3ChRealPowerBNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11120
Real Power B Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPow3ChApparentPowerBNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11121
Apparent Power B Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPow3ChPowerFactorBNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11122
Power Factor B Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPow3ChkWattHrsCNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11123
Kilo Watt Hours C Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPow3ChVoltsCNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11124
Volts C Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPow3ChVoltMaxCNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11125
Volts Max C Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPow3ChVoltMinCNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11126
Volts Min C Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPow3ChVoltPeakCNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11127
Volt Peak C Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPow3ChDeciAmpsCNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11128
Deciamps C Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPow3ChRealPowerCNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11129
Real Power C Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPow3ChApparentPowerCNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11130
Apparent Power C Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPow3ChPowerFactorCNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11131
Power Factor C Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPow3ChkWattHrsTotalNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11132
Kilo Watt Hours Total Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPow3ChRealPowerTotalNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11133
Real Power Total Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmOutlet1StatusNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11205
Outlet 1 Status Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmOutlet2StatusNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11206
Outlet 2 Status Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmVsfcSetPointCNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11305
Vsfc Temp Set Point Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmVsfcSetPointFNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11306
Vsfc Temp Set Point Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmVsfcFanSpeedNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11307
Vsfc Fan Speed Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmVsfcIntTempCNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11308
Vsfc Internal Temp Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmVsfcIntTempFNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11309
Vsfc Internal Temp Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmVsfcExt1TempCNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11310
Vsfc External Temp 1 Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmVsfcExt1TempFNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11311
Vsfc External Temp 1 Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmVsfcExt2TempCNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11312
Vsfc External Temp 2 Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmVsfcExt2TempFNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11313
Vsfc External Temp 1 Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmVsfcExt3TempCNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11314
Vsfc External Temp 3 Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmVsfcExt3TempFNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11315
Vsfc External Temp 1 Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmVsfcExt4TempCNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11316
Vsfc External Temp 4 Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmVsfcExt4TempFNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11317
Vsfc External Temp 1 Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChVoltsANOTIFY 1.3.6.1.4.1.17373.3.32767.0.11405
Volts A Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChVoltPeakANOTIFY 1.3.6.1.4.1.17373.3.32767.0.11406
Volts Peak A Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChDeciAmpsANOTIFY 1.3.6.1.4.1.17373.3.32767.0.11407
Deciamps A Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChDeciAmpsPeakANOTIFY 1.3.6.1.4.1.17373.3.32767.0.11408
Deciamps Peak A Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChRealPowerANOTIFY 1.3.6.1.4.1.17373.3.32767.0.11409
Real Power A Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChApparentPowerANOTIFY 1.3.6.1.4.1.17373.3.32767.0.11410
Apparent Power A Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChPowerFactorANOTIFY 1.3.6.1.4.1.17373.3.32767.0.11411
Power Factor A Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChVoltsBNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11412
Volts B Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChVoltPeakBNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11413
Volts Peak B Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChDeciAmpsBNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11414
Deciamps B Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChDeciAmpsPeakBNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11415
Deciamps Peak B Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChRealPowerBNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11416
Real Power B Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChApparentPowerBNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11417
Apparent Power B Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChPowerFactorBNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11418
Power Factor B Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChVoltsCNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11419
Volts C Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChVoltPeakCNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11420
Volts Peak C Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChDeciAmpsCNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11421
Deciamps C Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChDeciAmpsPeakCNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11422
Deciamps Peak C Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChRealPowerCNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11423
Real Power C Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChApparentPowerCNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11424
Apparent Power C Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChPowerFactorCNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11425
Power Factor C Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlGrpAmpsANOTIFY 1.3.6.1.4.1.17373.3.32767.0.11505
Group A DeciAmps Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlGrpAmpsBNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11506
Group B DeciAmps Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlGrpAmpsCNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11507
Group C DeciAmps Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlGrpAmpsDNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11508
Group D DeciAmps Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlGrpAmpsENOTIFY 1.3.6.1.4.1.17373.3.32767.0.11509
Group E DeciAmps Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlGrpAmpsFNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11510
Group F DeciAmps Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlGrpAmpsGNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11511
Group G DeciAmps Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlGrpAmpsHNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11512
Group H DeciAmps Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlGrpAmpsAVoltsNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11513
AVolts Trip Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlGrpAmpsBVoltsNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11514
BVolts Trip Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlGrpAmpsCVoltsNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11515
CVolts Trip Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlGrpAmpsDVoltsNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11516
DVolts Trip Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlGrpAmpsEVoltsNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11517
EVolts Trip Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlGrpAmpsFVoltsNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11518
FVolts Trip Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlGrpAmpsGVoltsNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11519
GVolts Trip Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlGrpAmpsHVoltsNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11520
HVolts Trip Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlGrpAmpsINOTIFY 1.3.6.1.4.1.17373.3.32767.0.11521
Group I DeciAmps Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlGrpAmpsJNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11522
Group J DeciAmps Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlGrpAmpsKNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11523
Group K DeciAmps Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlGrpAmpsLNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11524
Group L DeciAmps Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlGrpAmpsMNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11525
Group M DeciAmps Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlGrpAmpsNNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11526
Group N DeciAmps Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlGrpAmpsONOTIFY 1.3.6.1.4.1.17373.3.32767.0.11527
Group O DeciAmps Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlGrpAmpsPNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11528
Group P DeciAmps Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlGrpAmpsIVoltsNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11529
IVolts Trip Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlGrpAmpsJVoltsNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11530
JVolts Trip Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlGrpAmpsKVoltsNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11531
KVolts Trip Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlGrpAmpsLVoltsNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11532
LVolts Trip Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlGrpAmpsMVoltsNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11533
MVolts Trip Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlGrpAmpsNVoltsNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11534
NVolts Trip Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlGrpAmpsOVoltsNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11535
OVolts Trip Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlGrpAmpsPVoltsNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11536
PVolts Trip Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlOutletPendingNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11605
Pending Trip Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlOutletDeciAmpsNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11606
Outlet DeciAmps Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlOutletGroupNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11607
Group Trip Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlOutletUpDelayNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11608
UpDelay Trip Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlOutletDwnDelayNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11609
DwnDelay Trip Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlOutletRbtDurationNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11610
RbtDuration Trip Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlOutletURLNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11611
URL Trip Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlOutletPOAActionNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11612
POAAction Trip Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlOutletPOADelayNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11613
POADelay Trip Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlOutletkWattHrsNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11614
kWattHrs Trip Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlOutletPowerNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11615
Power Trip Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlOutletRbtDelayNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11616
RbtDelay Trip Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlOutletStatusTimeNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11617
StatusTime Trip Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmDewPointSensorTempCNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11705
Remote Dew Point Sensor - Temperature Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmDewPointSensorTempFNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11706
Remote Dew Point Sensor - Temperature Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmDewPointSensorHumidityNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11707
Remote Dew Point Sensor - Humidity
Status: current Access: read-create
NOTIFICATION-TYPE    

cmDewPointSensorDewPointCNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11708
Remote Dew Point Sensor - Dew Point Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmDewPointSensorDewPointFNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11709
Remote Dew Point Sensor - Dew Point Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmDigitalSensorDigitalNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11805
Digital sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmDstsVoltsANOTIFY 1.3.6.1.4.1.17373.3.32767.0.11905
RMS Voltage of Side A Set Point Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmDstsDeciAmpsANOTIFY 1.3.6.1.4.1.17373.3.32767.0.11906
RMS Current of Side A Set Point Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmDstsVoltsBNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11907
RMS Voltage of Side B Set Point Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmDstsDeciAmpsBNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11908
RMS Current of Side B Set Point Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmDstsSourceAActiveNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11909
Source A Active Set Point Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmDstsSourceBActiveNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11910
Source B Active Set Point Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmDstsPowerStatusANOTIFY 1.3.6.1.4.1.17373.3.32767.0.11911
Source A Power Qualilty Active Set Point Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmDstsPowerStatusBNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11912
Source B Power Qualilty Active Set Point Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmDstsSourceATempCNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11913
Source A Temp Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmDstsSourceBTempCNOTIFY 1.3.6.1.4.1.17373.3.32767.0.11914
Source B Temp Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCpmSensorStatusNOTIFY 1.3.6.1.4.1.17373.3.32767.0.12005
City Power sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmSmokeAlarmStatusNOTIFY 1.3.6.1.4.1.17373.3.32767.0.12105
Smoke alarm Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmNeg48VdcSensorVoltageNOTIFY 1.3.6.1.4.1.17373.3.32767.0.12205
-48Vdc Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPos30VdcSensorVoltageNOTIFY 1.3.6.1.4.1.17373.3.32767.0.12305
30Vdc Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmAnalogSensorAnalogNOTIFY 1.3.6.1.4.1.17373.3.32767.0.12405
Analog Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChIECkWattHrsANOTIFY 1.3.6.1.4.1.17373.3.32767.0.12505
Kilo Watt Hours A Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChIECVoltsANOTIFY 1.3.6.1.4.1.17373.3.32767.0.12506
Volts A Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChIECVoltPeakANOTIFY 1.3.6.1.4.1.17373.3.32767.0.12507
Volts Peak A Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChIECDeciAmpsANOTIFY 1.3.6.1.4.1.17373.3.32767.0.12508
Deciamps A Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChIECDeciAmpsPeakANOTIFY 1.3.6.1.4.1.17373.3.32767.0.12509
Deciamps Peak A Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChIECRealPowerANOTIFY 1.3.6.1.4.1.17373.3.32767.0.12510
Real Power A Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChIECApparentPowerANOTIFY 1.3.6.1.4.1.17373.3.32767.0.12511
Apparent Power A Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChIECPowerFactorANOTIFY 1.3.6.1.4.1.17373.3.32767.0.12512
Power Factor A Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChIECkWattHrsBNOTIFY 1.3.6.1.4.1.17373.3.32767.0.12513
Kilo Watt Hours B Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChIECVoltsBNOTIFY 1.3.6.1.4.1.17373.3.32767.0.12514
Volts B Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChIECVoltPeakBNOTIFY 1.3.6.1.4.1.17373.3.32767.0.12515
Volts Peak B Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChIECDeciAmpsBNOTIFY 1.3.6.1.4.1.17373.3.32767.0.12516
Deciamps B Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChIECDeciAmpsPeakBNOTIFY 1.3.6.1.4.1.17373.3.32767.0.12517
Deciamps Peak B Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChIECRealPowerBNOTIFY 1.3.6.1.4.1.17373.3.32767.0.12518
Real Power B Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChIECApparentPowerBNOTIFY 1.3.6.1.4.1.17373.3.32767.0.12519
Apparent Power B Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChIECPowerFactorBNOTIFY 1.3.6.1.4.1.17373.3.32767.0.12520
Power Factor B Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChIECkWattHrsCNOTIFY 1.3.6.1.4.1.17373.3.32767.0.12521
Kilo Watt Hours C Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChIECVoltsCNOTIFY 1.3.6.1.4.1.17373.3.32767.0.12522
Volts C Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChIECVoltPeakCNOTIFY 1.3.6.1.4.1.17373.3.32767.0.12523
Volts Peak C Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChIECDeciAmpsCNOTIFY 1.3.6.1.4.1.17373.3.32767.0.12524
Deciamps C Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChIECDeciAmpsPeakCNOTIFY 1.3.6.1.4.1.17373.3.32767.0.12525
Deciamps Peak C Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChIECRealPowerCNOTIFY 1.3.6.1.4.1.17373.3.32767.0.12526
Real Power C Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChIECApparentPowerCNOTIFY 1.3.6.1.4.1.17373.3.32767.0.12527
Apparent Power C Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChIECPowerFactorCNOTIFY 1.3.6.1.4.1.17373.3.32767.0.12528
Power Factor C Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChIECkWattHrsTotalNOTIFY 1.3.6.1.4.1.17373.3.32767.0.12529
Kilo Watt Hours Total Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChIECRealPowerTotalNOTIFY 1.3.6.1.4.1.17373.3.32767.0.12530
Watts Total Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmClimateRelayTempCNOTIFY 1.3.6.1.4.1.17373.3.32767.0.12605
Climate Relay Temperature Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmClimateRelayTempFNOTIFY 1.3.6.1.4.1.17373.3.32767.0.12606
Climate Relay Temperature Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmClimateRelayIO1NOTIFY 1.3.6.1.4.1.17373.3.32767.0.12607
Climate Relay IO1 Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmClimateRelayIO2NOTIFY 1.3.6.1.4.1.17373.3.32767.0.12608
Climate Relay IO2 Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmClimateRelayIO3NOTIFY 1.3.6.1.4.1.17373.3.32767.0.12609
Climate Relay IO3 Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmClimateRelayIO4NOTIFY 1.3.6.1.4.1.17373.3.32767.0.12610
Climate Relay IO4 Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmClimateRelayIO5NOTIFY 1.3.6.1.4.1.17373.3.32767.0.12611
Climate Relay IO5 Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmClimateRelayIO6NOTIFY 1.3.6.1.4.1.17373.3.32767.0.12612
Climate Relay IO6 Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmAirSpeedSwitchSensorAirSpeedNOTIFY 1.3.6.1.4.1.17373.3.32767.0.12805
Air Speed Switch Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps1NOTIFY 1.3.6.1.4.1.17373.3.32767.0.129153
DM48 Current Monitor Amps Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps2NOTIFY 1.3.6.1.4.1.17373.3.32767.0.129154
DM48 Current Monitor Amps Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps3NOTIFY 1.3.6.1.4.1.17373.3.32767.0.129155
DM48 Current Monitor Amps Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps4NOTIFY 1.3.6.1.4.1.17373.3.32767.0.129156
DM48 Current Monitor Amps Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps5NOTIFY 1.3.6.1.4.1.17373.3.32767.0.129157
DM48 Current Monitor Amps Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps6NOTIFY 1.3.6.1.4.1.17373.3.32767.0.129158
DM48 Current Monitor Amps Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps7NOTIFY 1.3.6.1.4.1.17373.3.32767.0.129159
DM48 Current Monitor Amps Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps8NOTIFY 1.3.6.1.4.1.17373.3.32767.0.129160
DM48 Current Monitor Amps Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps9NOTIFY 1.3.6.1.4.1.17373.3.32767.0.129161
DM48 Current Monitor Amps Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps10NOTIFY 1.3.6.1.4.1.17373.3.32767.0.129162
DM48 Current Monitor Amps Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps11NOTIFY 1.3.6.1.4.1.17373.3.32767.0.129163
DM48 Current Monitor Amps Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps12NOTIFY 1.3.6.1.4.1.17373.3.32767.0.129164
DM48 Current Monitor Amps Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps13NOTIFY 1.3.6.1.4.1.17373.3.32767.0.129165
DM48 Current Monitor Amps Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps14NOTIFY 1.3.6.1.4.1.17373.3.32767.0.129166
DM48 Current Monitor Amps Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps15NOTIFY 1.3.6.1.4.1.17373.3.32767.0.129167
DM48 Current Monitor Amps Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps16NOTIFY 1.3.6.1.4.1.17373.3.32767.0.129168
DM48 Current Monitor Amps Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps17NOTIFY 1.3.6.1.4.1.17373.3.32767.0.129169
DM48 Current Monitor Amps Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps18NOTIFY 1.3.6.1.4.1.17373.3.32767.0.129170
DM48 Current Monitor Amps Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps19NOTIFY 1.3.6.1.4.1.17373.3.32767.0.129171
DM48 Current Monitor Amps Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps20NOTIFY 1.3.6.1.4.1.17373.3.32767.0.129172
DM48 Current Monitor Amps Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps21NOTIFY 1.3.6.1.4.1.17373.3.32767.0.129173
DM48 Current Monitor Amps Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps22NOTIFY 1.3.6.1.4.1.17373.3.32767.0.129174
DM48 Current Monitor Amps Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps23NOTIFY 1.3.6.1.4.1.17373.3.32767.0.129175
DM48 Current Monitor Amps Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps24NOTIFY 1.3.6.1.4.1.17373.3.32767.0.129176
DM48 Current Monitor Amps Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps25NOTIFY 1.3.6.1.4.1.17373.3.32767.0.129177
DM48 Current Monitor Amps Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps26NOTIFY 1.3.6.1.4.1.17373.3.32767.0.129178
DM48 Current Monitor Amps Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps27NOTIFY 1.3.6.1.4.1.17373.3.32767.0.129179
DM48 Current Monitor Amps Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps28NOTIFY 1.3.6.1.4.1.17373.3.32767.0.129180
DM48 Current Monitor Amps Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps29NOTIFY 1.3.6.1.4.1.17373.3.32767.0.129181
DM48 Current Monitor Amps Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps30NOTIFY 1.3.6.1.4.1.17373.3.32767.0.129182
DM48 Current Monitor Amps Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps31NOTIFY 1.3.6.1.4.1.17373.3.32767.0.129183
DM48 Current Monitor Amps Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps32NOTIFY 1.3.6.1.4.1.17373.3.32767.0.129184
DM48 Current Monitor Amps Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps33NOTIFY 1.3.6.1.4.1.17373.3.32767.0.129185
DM48 Current Monitor Amps Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps34NOTIFY 1.3.6.1.4.1.17373.3.32767.0.129186
DM48 Current Monitor Amps Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps35NOTIFY 1.3.6.1.4.1.17373.3.32767.0.129187
DM48 Current Monitor Amps Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps36NOTIFY 1.3.6.1.4.1.17373.3.32767.0.129188
DM48 Current Monitor Amps Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps37NOTIFY 1.3.6.1.4.1.17373.3.32767.0.129189
DM48 Current Monitor Amps Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps38NOTIFY 1.3.6.1.4.1.17373.3.32767.0.129190
DM48 Current Monitor Amps Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps39NOTIFY 1.3.6.1.4.1.17373.3.32767.0.129191
DM48 Current Monitor Amps Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps40NOTIFY 1.3.6.1.4.1.17373.3.32767.0.129192
DM48 Current Monitor Amps Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps41NOTIFY 1.3.6.1.4.1.17373.3.32767.0.129193
DM48 Current Monitor Amps Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps42NOTIFY 1.3.6.1.4.1.17373.3.32767.0.129194
DM48 Current Monitor Amps Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps43NOTIFY 1.3.6.1.4.1.17373.3.32767.0.129195
DM48 Current Monitor Amps Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps44NOTIFY 1.3.6.1.4.1.17373.3.32767.0.129196
DM48 Current Monitor Amps Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps45NOTIFY 1.3.6.1.4.1.17373.3.32767.0.129197
DM48 Current Monitor Amps Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps46NOTIFY 1.3.6.1.4.1.17373.3.32767.0.129198
DM48 Current Monitor Amps Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps47NOTIFY 1.3.6.1.4.1.17373.3.32767.0.129199
DM48 Current Monitor Amps Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps48NOTIFY 1.3.6.1.4.1.17373.3.32767.0.129200
DM48 Current Monitor Amps Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmIoExpanderIO1NOTIFY 1.3.6.1.4.1.17373.3.32767.0.13037
Climate Relay IO1 Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmIoExpanderIO2NOTIFY 1.3.6.1.4.1.17373.3.32767.0.13038
Climate Relay IO2 Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmIoExpanderIO3NOTIFY 1.3.6.1.4.1.17373.3.32767.0.13039
Climate Relay IO3 Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmIoExpanderIO4NOTIFY 1.3.6.1.4.1.17373.3.32767.0.13040
Climate Relay IO4 Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmIoExpanderIO5NOTIFY 1.3.6.1.4.1.17373.3.32767.0.13041
Climate Relay IO5 Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmIoExpanderIO6NOTIFY 1.3.6.1.4.1.17373.3.32767.0.13042
Climate Relay IO6 Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmIoExpanderIO7NOTIFY 1.3.6.1.4.1.17373.3.32767.0.13043
Climate Relay IO7 Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmIoExpanderIO8NOTIFY 1.3.6.1.4.1.17373.3.32767.0.13044
Climate Relay IO8 Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmIoExpanderIO9NOTIFY 1.3.6.1.4.1.17373.3.32767.0.13045
Climate Relay IO9 Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmIoExpanderIO10NOTIFY 1.3.6.1.4.1.17373.3.32767.0.13046
Climate Relay IO10 Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmIoExpanderIO11NOTIFY 1.3.6.1.4.1.17373.3.32767.0.13047
Climate Relay IO11 Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmIoExpanderIO12NOTIFY 1.3.6.1.4.1.17373.3.32767.0.13048
Climate Relay IO12 Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmIoExpanderIO13NOTIFY 1.3.6.1.4.1.17373.3.32767.0.13049
Climate Relay IO13 Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmIoExpanderIO14NOTIFY 1.3.6.1.4.1.17373.3.32767.0.13050
Climate Relay IO14 Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmIoExpanderIO15NOTIFY 1.3.6.1.4.1.17373.3.32767.0.13051
Climate Relay IO15 Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmIoExpanderIO16NOTIFY 1.3.6.1.4.1.17373.3.32767.0.13052
Climate Relay IO16 Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmIoExpanderIO17NOTIFY 1.3.6.1.4.1.17373.3.32767.0.13053
Climate Relay IO17 Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmIoExpanderIO18NOTIFY 1.3.6.1.4.1.17373.3.32767.0.13054
Climate Relay IO18 Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmIoExpanderIO19NOTIFY 1.3.6.1.4.1.17373.3.32767.0.13055
Climate Relay IO19 Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmIoExpanderIO20NOTIFY 1.3.6.1.4.1.17373.3.32767.0.13056
Climate Relay IO20 Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmIoExpanderIO21NOTIFY 1.3.6.1.4.1.17373.3.32767.0.13057
Climate Relay IO21 Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmIoExpanderIO22NOTIFY 1.3.6.1.4.1.17373.3.32767.0.13058
Climate Relay IO22 Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmIoExpanderIO23NOTIFY 1.3.6.1.4.1.17373.3.32767.0.13059
Climate Relay IO23 Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmIoExpanderIO24NOTIFY 1.3.6.1.4.1.17373.3.32767.0.13060
Climate Relay IO24 Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmIoExpanderIO25NOTIFY 1.3.6.1.4.1.17373.3.32767.0.13061
Climate Relay IO25 Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmIoExpanderIO26NOTIFY 1.3.6.1.4.1.17373.3.32767.0.13062
Climate Relay IO26 Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmIoExpanderIO27NOTIFY 1.3.6.1.4.1.17373.3.32767.0.13063
Climate Relay IO27 Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmIoExpanderIO28NOTIFY 1.3.6.1.4.1.17373.3.32767.0.13064
Climate Relay IO28 Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmIoExpanderIO29NOTIFY 1.3.6.1.4.1.17373.3.32767.0.13065
Climate Relay IO29 Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmIoExpanderIO30NOTIFY 1.3.6.1.4.1.17373.3.32767.0.13066
Climate Relay IO30 Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmIoExpanderIO31NOTIFY 1.3.6.1.4.1.17373.3.32767.0.13067
Climate Relay IO31 Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmIoExpanderIO32NOTIFY 1.3.6.1.4.1.17373.3.32767.0.13068
Climate Relay IO32 Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmT3hdSensorIntTempCNOTIFY 1.3.6.1.4.1.17373.3.32767.0.13106
T3HD - Internal Temperature C Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmT3hdSensorIntTempFNOTIFY 1.3.6.1.4.1.17373.3.32767.0.13107
T3HD - Internal Temperature F Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmT3hdSensorIntHumidityNOTIFY 1.3.6.1.4.1.17373.3.32767.0.13108
T3HD - Internal Humidity Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmT3hdSensorIntDewPointCNOTIFY 1.3.6.1.4.1.17373.3.32767.0.13109
T3HD - Internal Dew Point C Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmT3hdSensorIntDewPointFNOTIFY 1.3.6.1.4.1.17373.3.32767.0.13110
T3HD - Internal Dew Point F Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmT3hdSensorExt1TempCNOTIFY 1.3.6.1.4.1.17373.3.32767.0.13113
T3HD - External 1 Temperature C Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmT3hdSensorExt1TempFNOTIFY 1.3.6.1.4.1.17373.3.32767.0.13114
T3HD - External 1 Temperature F Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmT3hdSensorExt2TempCNOTIFY 1.3.6.1.4.1.17373.3.32767.0.13117
T3HD - External 2 Temperature C Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmT3hdSensorExt2TempFNOTIFY 1.3.6.1.4.1.17373.3.32767.0.13118
T3HD - External 2 Temperature F Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmThdSensorTempCNOTIFY 1.3.6.1.4.1.17373.3.32767.0.13205
THD - Temperature C Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmThdSensorTempFNOTIFY 1.3.6.1.4.1.17373.3.32767.0.13206
THD - Temperature F Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmThdSensorHumidityNOTIFY 1.3.6.1.4.1.17373.3.32767.0.13207
THD - Humidity Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmThdSensorDewPointCNOTIFY 1.3.6.1.4.1.17373.3.32767.0.13208
THD - Dew Point C Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmThdSensorDewPointFNOTIFY 1.3.6.1.4.1.17373.3.32767.0.13209
THD - Dew Point F Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPos60VdcSensorVoltageNOTIFY 1.3.6.1.4.1.17373.3.32767.0.13305
60Vdc Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl2CirTotkWattHrsTotNOTIFY 1.3.6.1.4.1.17373.3.32767.0.13405
Kilo Watt Hours Total Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl2CirTotVoltsTotNOTIFY 1.3.6.1.4.1.17373.3.32767.0.13406
Volts A Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl2CirTotVoltPeakTotNOTIFY 1.3.6.1.4.1.17373.3.32767.0.13407
Volts Peak Total Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl2CirTotDeciAmpsTotNOTIFY 1.3.6.1.4.1.17373.3.32767.0.13408
Deciamps Total Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl2CirTotDeciAmpsPeakTotNOTIFY 1.3.6.1.4.1.17373.3.32767.0.13409
Deciamps Peak Total Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl2CirTotRealPowerTotNOTIFY 1.3.6.1.4.1.17373.3.32767.0.13410
Real Power Total Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl2CirTotApparentPowerTotNOTIFY 1.3.6.1.4.1.17373.3.32767.0.13411
Apparent Power Total Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl2CirTotPowerFactorTotNOTIFY 1.3.6.1.4.1.17373.3.32767.0.13412
Power Factor Total Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl2CirTotkWattHrsANOTIFY 1.3.6.1.4.1.17373.3.32767.0.13413
Kilo Watt Hours A Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl2CirTotVoltsANOTIFY 1.3.6.1.4.1.17373.3.32767.0.13414
Volts A Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl2CirTotVoltPeakANOTIFY 1.3.6.1.4.1.17373.3.32767.0.13415
Volts Peak A Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl2CirTotDeciAmpsANOTIFY 1.3.6.1.4.1.17373.3.32767.0.13416
Deciamps A Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl2CirTotDeciAmpsPeakANOTIFY 1.3.6.1.4.1.17373.3.32767.0.13417
Deciamps Peak A Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl2CirTotRealPowerANOTIFY 1.3.6.1.4.1.17373.3.32767.0.13418
Real Power A Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl2CirTotApparentPowerANOTIFY 1.3.6.1.4.1.17373.3.32767.0.13419
Apparent Power A Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl2CirTotPowerFactorANOTIFY 1.3.6.1.4.1.17373.3.32767.0.13420
Power Factor A Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl2CirTotkWattHrsBNOTIFY 1.3.6.1.4.1.17373.3.32767.0.13421
Kilo Watt Hours B Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl2CirTotVoltsBNOTIFY 1.3.6.1.4.1.17373.3.32767.0.13422
Volts B Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl2CirTotVoltPeakBNOTIFY 1.3.6.1.4.1.17373.3.32767.0.13423
Volts Peak B Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl2CirTotDeciAmpsBNOTIFY 1.3.6.1.4.1.17373.3.32767.0.13424
Deciamps B Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl2CirTotDeciAmpsPeakBNOTIFY 1.3.6.1.4.1.17373.3.32767.0.13425
Deciamps Peak B Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl2CirTotRealPowerBNOTIFY 1.3.6.1.4.1.17373.3.32767.0.13426
Real Power B Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl2CirTotApparentPowerBNOTIFY 1.3.6.1.4.1.17373.3.32767.0.13427
Apparent Power B Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl2CirTotPowerFactorBNOTIFY 1.3.6.1.4.1.17373.3.32767.0.13428
Power Factor B Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmSc10ControlModeNOTIFY 1.3.6.1.4.1.17373.3.32767.0.13505
SC10 Control Mode Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmSc10SetpointCNOTIFY 1.3.6.1.4.1.17373.3.32767.0.13506
SC10 Temp Set Point Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmSc10SetpointFNOTIFY 1.3.6.1.4.1.17373.3.32767.0.13507
SC10 Temp Set Point Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmSc10TempCNOTIFY 1.3.6.1.4.1.17373.3.32767.0.13508
SC10 Internal Temp Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmSc10TempFNOTIFY 1.3.6.1.4.1.17373.3.32767.0.13509
SC10 Internal Temp Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmSc10CapacityNOTIFY 1.3.6.1.4.1.17373.3.32767.0.13510
SC10 Fan Speed Sensor Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmClimateTempCCLEAR 1.3.6.1.4.1.17373.3.32767.0.20205
Climate Temperature Sensor Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmClimateTempFCLEAR 1.3.6.1.4.1.17373.3.32767.0.20206
Climate Temperature Sensor Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmClimateHumidityCLEAR 1.3.6.1.4.1.17373.3.32767.0.20207
Climate Humidity Sensor Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmClimateLightCLEAR 1.3.6.1.4.1.17373.3.32767.0.20208
Climate Light Sensor Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmClimateAirflowCLEAR 1.3.6.1.4.1.17373.3.32767.0.20209
Climate Air Flow Sensor Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmClimateSoundCLEAR 1.3.6.1.4.1.17373.3.32767.0.20210
Climate Sound Sensor Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmClimateIO1CLEAR 1.3.6.1.4.1.17373.3.32767.0.20211
Climate IO1 Sensor Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmClimateIO2CLEAR 1.3.6.1.4.1.17373.3.32767.0.20212
Climate IO2 Sensor Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmClimateIO3CLEAR 1.3.6.1.4.1.17373.3.32767.0.20213
Climate IO3 Sensor Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmClimateDewPointCCLEAR 1.3.6.1.4.1.17373.3.32767.0.20214
Climate Dew Point Sensor Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmClimateDewPointFCLEAR 1.3.6.1.4.1.17373.3.32767.0.20215
Climate Dew Point Sensor Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowMonkWattHrsCLEAR 1.3.6.1.4.1.17373.3.32767.0.20305
Kilo Watt Hours Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowMonVoltsCLEAR 1.3.6.1.4.1.17373.3.32767.0.20306
Volts Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowMonVoltMaxCLEAR 1.3.6.1.4.1.17373.3.32767.0.20307
Volts Max Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowMonVoltMinCLEAR 1.3.6.1.4.1.17373.3.32767.0.20308
Volts Min Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowMonVoltPeakCLEAR 1.3.6.1.4.1.17373.3.32767.0.20309
Volt Peak Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowMonDeciAmpsCLEAR 1.3.6.1.4.1.17373.3.32767.0.20310
DeciAmps Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowMonRealPowerCLEAR 1.3.6.1.4.1.17373.3.32767.0.20311
Real Power Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowMonApparentPowerCLEAR 1.3.6.1.4.1.17373.3.32767.0.20312
Apparent Power Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowMonPowerFactorCLEAR 1.3.6.1.4.1.17373.3.32767.0.20313
Power Factor Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowMonOutlet1CLEAR 1.3.6.1.4.1.17373.3.32767.0.20314
Outlet1 Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowMonOutlet2CLEAR 1.3.6.1.4.1.17373.3.32767.0.20315
Outlet2 Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowMonOutlet1StatusTimeCLEAR 1.3.6.1.4.1.17373.3.32767.0.20316
Outlet1StatusTime Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowMonOutlet2StatusTimeCLEAR 1.3.6.1.4.1.17373.3.32767.0.20317
Outlet2StatusTime Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmTempSensorTempCCLEAR 1.3.6.1.4.1.17373.3.32767.0.20405
Remote Temp Sensor - Temperature Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmTempSensorTempFCLEAR 1.3.6.1.4.1.17373.3.32767.0.20406
Remote Temp Sensor - Temperature Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmAirFlowSensorTempCCLEAR 1.3.6.1.4.1.17373.3.32767.0.20505
Remote Air Flow Sensor - Temperature Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmAirFlowSensorTempFCLEAR 1.3.6.1.4.1.17373.3.32767.0.20506
Remote Air Flow Sensor - Temperature Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmAirFlowSensorFlowCLEAR 1.3.6.1.4.1.17373.3.32767.0.20507
Remote Air Flow Sensor - Air Flow Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmAirFlowSensorHumidityCLEAR 1.3.6.1.4.1.17373.3.32767.0.20508
Remote Air Flow Sensor - Humidity Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmAirFlowSensorDewPointCCLEAR 1.3.6.1.4.1.17373.3.32767.0.20509
Remote Air Flow Sensor - Dew Point Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmAirFlowSensorDewPointFCLEAR 1.3.6.1.4.1.17373.3.32767.0.20510
Remote Air Flow Sensor - Dew Point Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChDELTADeciAmpsACLEAR 1.3.6.1.4.1.17373.3.32767.0.20606
Deciamps A Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChDELTADeciAmpsBCLEAR 1.3.6.1.4.1.17373.3.32767.0.20607
Deciamps B Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChDELTADeciAmpsCCLEAR 1.3.6.1.4.1.17373.3.32767.0.20608
Deciamps C Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChDELTAkWattHrsTotalCLEAR 1.3.6.1.4.1.17373.3.32767.0.20609
Kilo Watt Hours Total Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChDELTARealPowerTotalCLEAR 1.3.6.1.4.1.17373.3.32767.0.20610
Watts Total Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChDELTAkWattHrsABCLEAR 1.3.6.1.4.1.17373.3.32767.0.20611
Kilo Watt Hours A Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChDELTAVoltsABCLEAR 1.3.6.1.4.1.17373.3.32767.0.20612
Volts AB Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChDELTAVoltPeakABCLEAR 1.3.6.1.4.1.17373.3.32767.0.20613
Volts Peak AB Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChDELTARealPowerABCLEAR 1.3.6.1.4.1.17373.3.32767.0.20614
Real Power AB Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChDELTAApparentPowerABCLEAR 1.3.6.1.4.1.17373.3.32767.0.20615
VoltAmps AB Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChDELTAPowerFactorABCLEAR 1.3.6.1.4.1.17373.3.32767.0.20616
Power Factor AB Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChDELTAkWattHrsBCCLEAR 1.3.6.1.4.1.17373.3.32767.0.20617
Kilo Watt Hours BC Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChDELTAVoltsBCCLEAR 1.3.6.1.4.1.17373.3.32767.0.20618
Volts BC Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChDELTAVoltPeakBCCLEAR 1.3.6.1.4.1.17373.3.32767.0.20619
Volts Peak BC Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChDELTARealPowerBCCLEAR 1.3.6.1.4.1.17373.3.32767.0.20620
Real Power BC Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChDELTAApparentPowerBCCLEAR 1.3.6.1.4.1.17373.3.32767.0.20621
VoltAmps BC Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChDELTAPowerFactorBCCLEAR 1.3.6.1.4.1.17373.3.32767.0.20622
Power Factor BC Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChDELTAkWattHrsCACLEAR 1.3.6.1.4.1.17373.3.32767.0.20623
Kilo Watt Hours CA Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChDELTAVoltsCACLEAR 1.3.6.1.4.1.17373.3.32767.0.20624
Volts CA Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChDELTAVoltPeakCACLEAR 1.3.6.1.4.1.17373.3.32767.0.20625
Volts Peak CA Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChDELTARealPowerCACLEAR 1.3.6.1.4.1.17373.3.32767.0.20626
Real Power CA Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChDELTAApparentPowerCACLEAR 1.3.6.1.4.1.17373.3.32767.0.20627
VoltAmps CA Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChDELTAPowerFactorCACLEAR 1.3.6.1.4.1.17373.3.32767.0.20628
Power Factor CA Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmDoorSensorStatusCLEAR 1.3.6.1.4.1.17373.3.32767.0.20705
Door sensor Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmWaterSensorDampnessCLEAR 1.3.6.1.4.1.17373.3.32767.0.20805
Water sensor Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCurrentMonitorDeciAmpsCLEAR 1.3.6.1.4.1.17373.3.32767.0.20905
Current Monitor Amps Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmMillivoltMonitorMVCLEAR 1.3.6.1.4.1.17373.3.32767.0.21005
Millivolt Monitor Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPow3ChkWattHrsACLEAR 1.3.6.1.4.1.17373.3.32767.0.21105
Kilo Watt Hours A Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPow3ChVoltsACLEAR 1.3.6.1.4.1.17373.3.32767.0.21106
Volts A Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPow3ChVoltMaxACLEAR 1.3.6.1.4.1.17373.3.32767.0.21107
Volts Max A Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPow3ChVoltMinACLEAR 1.3.6.1.4.1.17373.3.32767.0.21108
Volts Min A Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPow3ChVoltPeakACLEAR 1.3.6.1.4.1.17373.3.32767.0.21109
Volt Peak A Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPow3ChDeciAmpsACLEAR 1.3.6.1.4.1.17373.3.32767.0.21110
Deciamps A Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPow3ChRealPowerACLEAR 1.3.6.1.4.1.17373.3.32767.0.21111
Real Power A Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPow3ChApparentPowerACLEAR 1.3.6.1.4.1.17373.3.32767.0.21112
Apparent Power A Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPow3ChPowerFactorACLEAR 1.3.6.1.4.1.17373.3.32767.0.21113
Power Factor A Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPow3ChkWattHrsBCLEAR 1.3.6.1.4.1.17373.3.32767.0.21114
Kilo Watt Hours B Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPow3ChVoltsBCLEAR 1.3.6.1.4.1.17373.3.32767.0.21115
Volts B Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPow3ChVoltMaxBCLEAR 1.3.6.1.4.1.17373.3.32767.0.21116
Volts Max B Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPow3ChVoltMinBCLEAR 1.3.6.1.4.1.17373.3.32767.0.21117
Volts Min B Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPow3ChVoltPeakBCLEAR 1.3.6.1.4.1.17373.3.32767.0.21118
Volt Peak B Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPow3ChDeciAmpsBCLEAR 1.3.6.1.4.1.17373.3.32767.0.21119
Deciamps B Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPow3ChRealPowerBCLEAR 1.3.6.1.4.1.17373.3.32767.0.21120
Real Power B Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPow3ChApparentPowerBCLEAR 1.3.6.1.4.1.17373.3.32767.0.21121
Apparent Power B Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPow3ChPowerFactorBCLEAR 1.3.6.1.4.1.17373.3.32767.0.21122
Power Factor B Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPow3ChkWattHrsCCLEAR 1.3.6.1.4.1.17373.3.32767.0.21123
Kilo Watt Hours C Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPow3ChVoltsCCLEAR 1.3.6.1.4.1.17373.3.32767.0.21124
Volts C Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPow3ChVoltMaxCCLEAR 1.3.6.1.4.1.17373.3.32767.0.21125
Volts Max C Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPow3ChVoltMinCCLEAR 1.3.6.1.4.1.17373.3.32767.0.21126
Volts Min C Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPow3ChVoltPeakCCLEAR 1.3.6.1.4.1.17373.3.32767.0.21127
Volt Peak C Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPow3ChDeciAmpsCCLEAR 1.3.6.1.4.1.17373.3.32767.0.21128
Deciamps C Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPow3ChRealPowerCCLEAR 1.3.6.1.4.1.17373.3.32767.0.21129
Real Power C Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPow3ChApparentPowerCCLEAR 1.3.6.1.4.1.17373.3.32767.0.21130
Apparent Power C Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPow3ChPowerFactorCCLEAR 1.3.6.1.4.1.17373.3.32767.0.21131
Power Factor C Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPow3ChkWattHrsTotalCLEAR 1.3.6.1.4.1.17373.3.32767.0.21132
Kilo Watt Hours Total Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPow3ChRealPowerTotalCLEAR 1.3.6.1.4.1.17373.3.32767.0.21133
Real Power Total Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmOutlet1StatusCLEAR 1.3.6.1.4.1.17373.3.32767.0.21205
Outlet 1 Status Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmOutlet2StatusCLEAR 1.3.6.1.4.1.17373.3.32767.0.21206
Outlet 2 Status Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmVsfcSetPointCCLEAR 1.3.6.1.4.1.17373.3.32767.0.21305
Vsfc Temp Set Point Sensor Clear
Status: current Access: read-create
NOTIFICATION-TYPE    

cmVsfcSetPointFCLEAR 1.3.6.1.4.1.17373.3.32767.0.21306
Vsfc Temp Set Point Sensor Clear
Status: current Access: read-create
NOTIFICATION-TYPE    

cmVsfcFanSpeedCLEAR 1.3.6.1.4.1.17373.3.32767.0.21307
Vsfc Fan Speed Sensor Clear
Status: current Access: read-create
NOTIFICATION-TYPE    

cmVsfcIntTempCCLEAR 1.3.6.1.4.1.17373.3.32767.0.21308
Vsfc Internal Temp Sensor Clear
Status: current Access: read-create
NOTIFICATION-TYPE    

cmVsfcIntTempFCLEAR 1.3.6.1.4.1.17373.3.32767.0.21309
Vsfc Internal Temp Sensor Clear
Status: current Access: read-create
NOTIFICATION-TYPE    

cmVsfcExt1TempCCLEAR 1.3.6.1.4.1.17373.3.32767.0.21310
Vsfc External Temp 1 Sensor Clear
Status: current Access: read-create
NOTIFICATION-TYPE    

cmVsfcExt1TempFCLEAR 1.3.6.1.4.1.17373.3.32767.0.21311
Vsfc External Temp 1 Sensor Clear
Status: current Access: read-create
NOTIFICATION-TYPE    

cmVsfcExt2TempCCLEAR 1.3.6.1.4.1.17373.3.32767.0.21312
Vsfc External Temp 2 Sensor Clear
Status: current Access: read-create
NOTIFICATION-TYPE    

cmVsfcExt2TempFCLEAR 1.3.6.1.4.1.17373.3.32767.0.21313
Vsfc External Temp 1 Sensor Clear
Status: current Access: read-create
NOTIFICATION-TYPE    

cmVsfcExt3TempCCLEAR 1.3.6.1.4.1.17373.3.32767.0.21314
Vsfc External Temp 3 Sensor Clear
Status: current Access: read-create
NOTIFICATION-TYPE    

cmVsfcExt3TempFCLEAR 1.3.6.1.4.1.17373.3.32767.0.21315
Vsfc External Temp 1 Sensor Clear
Status: current Access: read-create
NOTIFICATION-TYPE    

cmVsfcExt4TempCCLEAR 1.3.6.1.4.1.17373.3.32767.0.21316
Vsfc External Temp 4 Sensor Clear
Status: current Access: read-create
NOTIFICATION-TYPE    

cmVsfcExt4TempFCLEAR 1.3.6.1.4.1.17373.3.32767.0.21317
Vsfc External Temp 1 Sensor Clear
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChVoltsACLEAR 1.3.6.1.4.1.17373.3.32767.0.21405
Volts A Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChVoltPeakACLEAR 1.3.6.1.4.1.17373.3.32767.0.21406
Volts Peak A Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChDeciAmpsACLEAR 1.3.6.1.4.1.17373.3.32767.0.21407
Deciamps A Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChDeciAmpsPeakACLEAR 1.3.6.1.4.1.17373.3.32767.0.21408
Deciamps Peak A Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChRealPowerACLEAR 1.3.6.1.4.1.17373.3.32767.0.21409
Real Power A Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChApparentPowerACLEAR 1.3.6.1.4.1.17373.3.32767.0.21410
Apparent Power A Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChPowerFactorACLEAR 1.3.6.1.4.1.17373.3.32767.0.21411
Power Factor A Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChVoltsBCLEAR 1.3.6.1.4.1.17373.3.32767.0.21412
Volts B Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChVoltPeakBCLEAR 1.3.6.1.4.1.17373.3.32767.0.21413
Volts Peak B Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChDeciAmpsBCLEAR 1.3.6.1.4.1.17373.3.32767.0.21414
Deciamps B Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChDeciAmpsPeakBCLEAR 1.3.6.1.4.1.17373.3.32767.0.21415
Deciamps Peak B Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChRealPowerBCLEAR 1.3.6.1.4.1.17373.3.32767.0.21416
Real Power B Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChApparentPowerBCLEAR 1.3.6.1.4.1.17373.3.32767.0.21417
Apparent Power B Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChPowerFactorBCLEAR 1.3.6.1.4.1.17373.3.32767.0.21418
Power Factor B Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChVoltsCCLEAR 1.3.6.1.4.1.17373.3.32767.0.21419
Volts C Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChVoltPeakCCLEAR 1.3.6.1.4.1.17373.3.32767.0.21420
Volts Peak C Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChDeciAmpsCCLEAR 1.3.6.1.4.1.17373.3.32767.0.21421
Deciamps C Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChDeciAmpsPeakCCLEAR 1.3.6.1.4.1.17373.3.32767.0.21422
Deciamps Peak C Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChRealPowerCCLEAR 1.3.6.1.4.1.17373.3.32767.0.21423
Real Power C Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChApparentPowerCCLEAR 1.3.6.1.4.1.17373.3.32767.0.21424
Apparent Power C Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChPowerFactorCCLEAR 1.3.6.1.4.1.17373.3.32767.0.21425
Power Factor C Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlGrpAmpsACLEAR 1.3.6.1.4.1.17373.3.32767.0.21505
Group A DeciAmps Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlGrpAmpsBCLEAR 1.3.6.1.4.1.17373.3.32767.0.21506
Group B DeciAmps Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlGrpAmpsCCLEAR 1.3.6.1.4.1.17373.3.32767.0.21507
Group C DeciAmps Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlGrpAmpsDCLEAR 1.3.6.1.4.1.17373.3.32767.0.21508
Group D DeciAmps Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlGrpAmpsECLEAR 1.3.6.1.4.1.17373.3.32767.0.21509
Group E DeciAmps Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlGrpAmpsFCLEAR 1.3.6.1.4.1.17373.3.32767.0.21510
Group F DeciAmps Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlGrpAmpsGCLEAR 1.3.6.1.4.1.17373.3.32767.0.21511
Group G DeciAmps Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlGrpAmpsHCLEAR 1.3.6.1.4.1.17373.3.32767.0.21512
Group H DeciAmps Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlGrpAmpsAVoltsCLEAR 1.3.6.1.4.1.17373.3.32767.0.21513
AVolts Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlGrpAmpsBVoltsCLEAR 1.3.6.1.4.1.17373.3.32767.0.21514
BVolts Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlGrpAmpsCVoltsCLEAR 1.3.6.1.4.1.17373.3.32767.0.21515
CVolts Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlGrpAmpsDVoltsCLEAR 1.3.6.1.4.1.17373.3.32767.0.21516
DVolts Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlGrpAmpsEVoltsCLEAR 1.3.6.1.4.1.17373.3.32767.0.21517
EVolts Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlGrpAmpsFVoltsCLEAR 1.3.6.1.4.1.17373.3.32767.0.21518
FVolts Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlGrpAmpsGVoltsCLEAR 1.3.6.1.4.1.17373.3.32767.0.21519
GVolts Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlGrpAmpsHVoltsCLEAR 1.3.6.1.4.1.17373.3.32767.0.21520
HVolts Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlGrpAmpsICLEAR 1.3.6.1.4.1.17373.3.32767.0.21521
Group I DeciAmps Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlGrpAmpsJCLEAR 1.3.6.1.4.1.17373.3.32767.0.21522
Group J DeciAmps Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlGrpAmpsKCLEAR 1.3.6.1.4.1.17373.3.32767.0.21523
Group K DeciAmps Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlGrpAmpsLCLEAR 1.3.6.1.4.1.17373.3.32767.0.21524
Group L DeciAmps Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlGrpAmpsMCLEAR 1.3.6.1.4.1.17373.3.32767.0.21525
Group M DeciAmps Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlGrpAmpsNCLEAR 1.3.6.1.4.1.17373.3.32767.0.21526
Group N DeciAmps Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlGrpAmpsOCLEAR 1.3.6.1.4.1.17373.3.32767.0.21527
Group O DeciAmps Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlGrpAmpsPCLEAR 1.3.6.1.4.1.17373.3.32767.0.21528
Group P DeciAmps Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlGrpAmpsIVoltsCLEAR 1.3.6.1.4.1.17373.3.32767.0.21529
IVolts Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlGrpAmpsJVoltsCLEAR 1.3.6.1.4.1.17373.3.32767.0.21530
JVolts Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlGrpAmpsKVoltsCLEAR 1.3.6.1.4.1.17373.3.32767.0.21531
KVolts Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlGrpAmpsLVoltsCLEAR 1.3.6.1.4.1.17373.3.32767.0.21532
LVolts Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlGrpAmpsMVoltsCLEAR 1.3.6.1.4.1.17373.3.32767.0.21533
MVolts Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlGrpAmpsNVoltsCLEAR 1.3.6.1.4.1.17373.3.32767.0.21534
NVolts Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlGrpAmpsOVoltsCLEAR 1.3.6.1.4.1.17373.3.32767.0.21535
OVolts Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlGrpAmpsPVoltsCLEAR 1.3.6.1.4.1.17373.3.32767.0.21536
PVolts Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlOutletPendingCLEAR 1.3.6.1.4.1.17373.3.32767.0.21605
Pending Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlOutletDeciAmpsCLEAR 1.3.6.1.4.1.17373.3.32767.0.21606
Outlet DeciAmps Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlOutletGroupCLEAR 1.3.6.1.4.1.17373.3.32767.0.21607
Group Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlOutletUpDelayCLEAR 1.3.6.1.4.1.17373.3.32767.0.21608
UpDelay Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlOutletDwnDelayCLEAR 1.3.6.1.4.1.17373.3.32767.0.21609
DwnDelay Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlOutletRbtDurationCLEAR 1.3.6.1.4.1.17373.3.32767.0.21610
RbtDuration Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlOutletURLCLEAR 1.3.6.1.4.1.17373.3.32767.0.21611
URL Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlOutletPOAActionCLEAR 1.3.6.1.4.1.17373.3.32767.0.21612
POAAction Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlOutletPOADelayCLEAR 1.3.6.1.4.1.17373.3.32767.0.21613
POADelay Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlOutletkWattHrsCLEAR 1.3.6.1.4.1.17373.3.32767.0.21614
kWattHrs Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlOutletPowerCLEAR 1.3.6.1.4.1.17373.3.32767.0.21615
Power Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlOutletRbtDelayCLEAR 1.3.6.1.4.1.17373.3.32767.0.21616
RbtDelay Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrlOutletStatusTimeCLEAR 1.3.6.1.4.1.17373.3.32767.0.21617
StatusTime Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmDewPointSensorTempCCLEAR 1.3.6.1.4.1.17373.3.32767.0.21705
Remote Dew Point Sensor - Temperature Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmDewPointSensorTempFCLEAR 1.3.6.1.4.1.17373.3.32767.0.21706
Remote Dew Point Sensor - Temperature Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmDewPointSensorHumidityCLEAR 1.3.6.1.4.1.17373.3.32767.0.21707
Remote Dew Point Sensor - Humidity Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmDewPointSensorDewPointCCLEAR 1.3.6.1.4.1.17373.3.32767.0.21708
Remote Dew Point Sensor - Dew Point Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmDewPointSensorDewPointFCLEAR 1.3.6.1.4.1.17373.3.32767.0.21709
Remote Dew Point Sensor - Dew Point Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmDigitalSensorDigitalCLEAR 1.3.6.1.4.1.17373.3.32767.0.21805
Digital sensor Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmDstsVoltsACLEAR 1.3.6.1.4.1.17373.3.32767.0.21905
RMS Voltage of Side A Set Point Sensor Clear
Status: current Access: read-create
NOTIFICATION-TYPE    

cmDstsDeciAmpsACLEAR 1.3.6.1.4.1.17373.3.32767.0.21906
RMS Current of Side A Set Point Sensor Clear
Status: current Access: read-create
NOTIFICATION-TYPE    

cmDstsVoltsBCLEAR 1.3.6.1.4.1.17373.3.32767.0.21907
RMS Voltage of Side B Set Point Sensor Clear
Status: current Access: read-create
NOTIFICATION-TYPE    

cmDstsDeciAmpsBCLEAR 1.3.6.1.4.1.17373.3.32767.0.21908
RMS Current of Side B Set Point Sensor Clear
Status: current Access: read-create
NOTIFICATION-TYPE    

cmDstsSourceAActiveCLEAR 1.3.6.1.4.1.17373.3.32767.0.21909
Source A Active Set Point Sensor Clear
Status: current Access: read-create
NOTIFICATION-TYPE    

cmDstsSourceBActiveCLEAR 1.3.6.1.4.1.17373.3.32767.0.21910
Source B Active Set Point Sensor Clear
Status: current Access: read-create
NOTIFICATION-TYPE    

cmDstsPowerStatusACLEAR 1.3.6.1.4.1.17373.3.32767.0.21911
Source A Power Qualilty Active Set Point Sensor Clear
Status: current Access: read-create
NOTIFICATION-TYPE    

cmDstsPowerStatusBCLEAR 1.3.6.1.4.1.17373.3.32767.0.21912
Source B Power Qualilty Active Set Point Sensor Clear
Status: current Access: read-create
NOTIFICATION-TYPE    

cmDstsSourceATempCCLEAR 1.3.6.1.4.1.17373.3.32767.0.21913
Source A Temp Sensor Clear
Status: current Access: read-create
NOTIFICATION-TYPE    

cmDstsSourceBTempCCLEAR 1.3.6.1.4.1.17373.3.32767.0.21914
Source B Temp Sensor Clear
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCpmSensorStatusCLEAR 1.3.6.1.4.1.17373.3.32767.0.22005
City Power sensor Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmSmokeAlarmStatusCLEAR 1.3.6.1.4.1.17373.3.32767.0.22105
Smoke alarm Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmNeg48VdcSensorVoltageCLEAR 1.3.6.1.4.1.17373.3.32767.0.22205
-48Vdc Sensor Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPos30VdcSensorVoltageCLEAR 1.3.6.1.4.1.17373.3.32767.0.22305
30Vdc Sensor Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmAnalogSensorAnalogCLEAR 1.3.6.1.4.1.17373.3.32767.0.22405
Analog Sensor Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChIECkWattHrsACLEAR 1.3.6.1.4.1.17373.3.32767.0.22505
Kilo Watt Hours A Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChIECVoltsACLEAR 1.3.6.1.4.1.17373.3.32767.0.22506
Volts A Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChIECVoltPeakACLEAR 1.3.6.1.4.1.17373.3.32767.0.22507
Volts Peak A Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChIECDeciAmpsACLEAR 1.3.6.1.4.1.17373.3.32767.0.22508
Deciamps A Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChIECDeciAmpsPeakACLEAR 1.3.6.1.4.1.17373.3.32767.0.22509
Deciamps Peak A Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChIECRealPowerACLEAR 1.3.6.1.4.1.17373.3.32767.0.22510
Real Power A Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChIECApparentPowerACLEAR 1.3.6.1.4.1.17373.3.32767.0.22511
Apparent Power A Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChIECPowerFactorACLEAR 1.3.6.1.4.1.17373.3.32767.0.22512
Power Factor A Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChIECkWattHrsBCLEAR 1.3.6.1.4.1.17373.3.32767.0.22513
Kilo Watt Hours B Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChIECVoltsBCLEAR 1.3.6.1.4.1.17373.3.32767.0.22514
Volts B Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChIECVoltPeakBCLEAR 1.3.6.1.4.1.17373.3.32767.0.22515
Volts Peak B Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChIECDeciAmpsBCLEAR 1.3.6.1.4.1.17373.3.32767.0.22516
Deciamps B Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChIECDeciAmpsPeakBCLEAR 1.3.6.1.4.1.17373.3.32767.0.22517
Deciamps Peak B Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChIECRealPowerBCLEAR 1.3.6.1.4.1.17373.3.32767.0.22518
Real Power B Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChIECApparentPowerBCLEAR 1.3.6.1.4.1.17373.3.32767.0.22519
Apparent Power B Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChIECPowerFactorBCLEAR 1.3.6.1.4.1.17373.3.32767.0.22520
Power Factor B Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChIECkWattHrsCCLEAR 1.3.6.1.4.1.17373.3.32767.0.22521
Kilo Watt Hours C Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChIECVoltsCCLEAR 1.3.6.1.4.1.17373.3.32767.0.22522
Volts C Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChIECVoltPeakCCLEAR 1.3.6.1.4.1.17373.3.32767.0.22523
Volts Peak C Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChIECDeciAmpsCCLEAR 1.3.6.1.4.1.17373.3.32767.0.22524
Deciamps C Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChIECDeciAmpsPeakCCLEAR 1.3.6.1.4.1.17373.3.32767.0.22525
Deciamps Peak C Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChIECRealPowerCCLEAR 1.3.6.1.4.1.17373.3.32767.0.22526
Real Power C Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChIECApparentPowerCCLEAR 1.3.6.1.4.1.17373.3.32767.0.22527
Apparent Power C Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChIECPowerFactorCCLEAR 1.3.6.1.4.1.17373.3.32767.0.22528
Power Factor C Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChIECkWattHrsTotalCLEAR 1.3.6.1.4.1.17373.3.32767.0.22529
Kilo Watt Hours Total Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl3ChIECRealPowerTotalCLEAR 1.3.6.1.4.1.17373.3.32767.0.22530
Watts Total Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmClimateRelayTempCCLEAR 1.3.6.1.4.1.17373.3.32767.0.22605
Climate Relay Temperature Sensor Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmClimateRelayTempFCLEAR 1.3.6.1.4.1.17373.3.32767.0.22606
Climate Relay Temperature Sensor Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmClimateRelayIO1CLEAR 1.3.6.1.4.1.17373.3.32767.0.22607
Climate Relay IO1 Sensor Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmClimateRelayIO2CLEAR 1.3.6.1.4.1.17373.3.32767.0.22608
Climate Relay IO2 Sensor Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmClimateRelayIO3CLEAR 1.3.6.1.4.1.17373.3.32767.0.22609
Climate Relay IO3 Sensor Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmClimateRelayIO4CLEAR 1.3.6.1.4.1.17373.3.32767.0.22610
Climate Relay IO4 Sensor Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmClimateRelayIO5CLEAR 1.3.6.1.4.1.17373.3.32767.0.22611
Climate Relay IO5 Sensor Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmClimateRelayIO6CLEAR 1.3.6.1.4.1.17373.3.32767.0.22612
Climate Relay IO6 Sensor Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmAirSpeedSwitchSensorAirSpeedCLEAR 1.3.6.1.4.1.17373.3.32767.0.22805
Air Speed Switch Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps1CLEAR 1.3.6.1.4.1.17373.3.32767.0.139153
DM48 Current Monitor Amps Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps2CLEAR 1.3.6.1.4.1.17373.3.32767.0.139154
DM48 Current Monitor Amps Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps3CLEAR 1.3.6.1.4.1.17373.3.32767.0.139155
DM48 Current Monitor Amps Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps4CLEAR 1.3.6.1.4.1.17373.3.32767.0.139156
DM48 Current Monitor Amps Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps5CLEAR 1.3.6.1.4.1.17373.3.32767.0.139157
DM48 Current Monitor Amps Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps6CLEAR 1.3.6.1.4.1.17373.3.32767.0.139158
DM48 Current Monitor Amps Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps7CLEAR 1.3.6.1.4.1.17373.3.32767.0.139159
DM48 Current Monitor Amps Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps8CLEAR 1.3.6.1.4.1.17373.3.32767.0.139160
DM48 Current Monitor Amps Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps9CLEAR 1.3.6.1.4.1.17373.3.32767.0.139161
DM48 Current Monitor Amps Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps10CLEAR 1.3.6.1.4.1.17373.3.32767.0.139162
DM48 Current Monitor Amps Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps11CLEAR 1.3.6.1.4.1.17373.3.32767.0.139163
DM48 Current Monitor Amps Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps12CLEAR 1.3.6.1.4.1.17373.3.32767.0.139164
DM48 Current Monitor Amps Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps13CLEAR 1.3.6.1.4.1.17373.3.32767.0.139165
DM48 Current Monitor Amps Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps14CLEAR 1.3.6.1.4.1.17373.3.32767.0.139166
DM48 Current Monitor Amps Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps15CLEAR 1.3.6.1.4.1.17373.3.32767.0.139167
DM48 Current Monitor Amps Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps16CLEAR 1.3.6.1.4.1.17373.3.32767.0.139168
DM48 Current Monitor Amps Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps17CLEAR 1.3.6.1.4.1.17373.3.32767.0.139169
DM48 Current Monitor Amps Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps18CLEAR 1.3.6.1.4.1.17373.3.32767.0.139170
DM48 Current Monitor Amps Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps19CLEAR 1.3.6.1.4.1.17373.3.32767.0.139171
DM48 Current Monitor Amps Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps20CLEAR 1.3.6.1.4.1.17373.3.32767.0.139172
DM48 Current Monitor Amps Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps21CLEAR 1.3.6.1.4.1.17373.3.32767.0.139173
DM48 Current Monitor Amps Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps22CLEAR 1.3.6.1.4.1.17373.3.32767.0.139174
DM48 Current Monitor Amps Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps23CLEAR 1.3.6.1.4.1.17373.3.32767.0.139175
DM48 Current Monitor Amps Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps24CLEAR 1.3.6.1.4.1.17373.3.32767.0.139176
DM48 Current Monitor Amps Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps25CLEAR 1.3.6.1.4.1.17373.3.32767.0.139177
DM48 Current Monitor Amps Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps26CLEAR 1.3.6.1.4.1.17373.3.32767.0.139178
DM48 Current Monitor Amps Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps27CLEAR 1.3.6.1.4.1.17373.3.32767.0.139179
DM48 Current Monitor Amps Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps28CLEAR 1.3.6.1.4.1.17373.3.32767.0.139180
DM48 Current Monitor Amps Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps29CLEAR 1.3.6.1.4.1.17373.3.32767.0.139181
DM48 Current Monitor Amps Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps30CLEAR 1.3.6.1.4.1.17373.3.32767.0.139182
DM48 Current Monitor Amps Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps31CLEAR 1.3.6.1.4.1.17373.3.32767.0.139183
DM48 Current Monitor Amps Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps32CLEAR 1.3.6.1.4.1.17373.3.32767.0.139184
DM48 Current Monitor Amps Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps33CLEAR 1.3.6.1.4.1.17373.3.32767.0.139185
DM48 Current Monitor Amps Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps34CLEAR 1.3.6.1.4.1.17373.3.32767.0.139186
DM48 Current Monitor Amps Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps35CLEAR 1.3.6.1.4.1.17373.3.32767.0.139187
DM48 Current Monitor Amps Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps36CLEAR 1.3.6.1.4.1.17373.3.32767.0.139188
DM48 Current Monitor Amps Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps37CLEAR 1.3.6.1.4.1.17373.3.32767.0.139189
DM48 Current Monitor Amps Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps38CLEAR 1.3.6.1.4.1.17373.3.32767.0.139190
DM48 Current Monitor Amps Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps39CLEAR 1.3.6.1.4.1.17373.3.32767.0.139191
DM48 Current Monitor Amps Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps40CLEAR 1.3.6.1.4.1.17373.3.32767.0.139192
DM48 Current Monitor Amps Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps41CLEAR 1.3.6.1.4.1.17373.3.32767.0.139193
DM48 Current Monitor Amps Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps42CLEAR 1.3.6.1.4.1.17373.3.32767.0.139194
DM48 Current Monitor Amps Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps43CLEAR 1.3.6.1.4.1.17373.3.32767.0.139195
DM48 Current Monitor Amps Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps44CLEAR 1.3.6.1.4.1.17373.3.32767.0.139196
DM48 Current Monitor Amps Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps45CLEAR 1.3.6.1.4.1.17373.3.32767.0.139197
DM48 Current Monitor Amps Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps46CLEAR 1.3.6.1.4.1.17373.3.32767.0.139198
DM48 Current Monitor Amps Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps47CLEAR 1.3.6.1.4.1.17373.3.32767.0.139199
DM48 Current Monitor Amps Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPowerDMDeciAmps48CLEAR 1.3.6.1.4.1.17373.3.32767.0.139200
DM48 Current Monitor Amps Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmIoExpanderIO1CLEAR 1.3.6.1.4.1.17373.3.32767.0.23037
Climate Relay IO1 Sensor Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmIoExpanderIO2CLEAR 1.3.6.1.4.1.17373.3.32767.0.23038
Climate Relay IO2 Sensor Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmIoExpanderIO3CLEAR 1.3.6.1.4.1.17373.3.32767.0.23039
Climate Relay IO3 Sensor Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmIoExpanderIO4CLEAR 1.3.6.1.4.1.17373.3.32767.0.23040
Climate Relay IO4 Sensor Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmIoExpanderIO5CLEAR 1.3.6.1.4.1.17373.3.32767.0.23041
Climate Relay IO5 Sensor Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmIoExpanderIO6CLEAR 1.3.6.1.4.1.17373.3.32767.0.23042
Climate Relay IO6 Sensor Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmIoExpanderIO7CLEAR 1.3.6.1.4.1.17373.3.32767.0.23043
Climate Relay IO7 Sensor Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmIoExpanderIO8CLEAR 1.3.6.1.4.1.17373.3.32767.0.23044
Climate Relay IO8 Sensor Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmIoExpanderIO9CLEAR 1.3.6.1.4.1.17373.3.32767.0.23045
Climate Relay IO9 Sensor Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmIoExpanderIO10CLEAR 1.3.6.1.4.1.17373.3.32767.0.23046
Climate Relay IO10 Sensor Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmIoExpanderIO11CLEAR 1.3.6.1.4.1.17373.3.32767.0.23047
Climate Relay IO11 Sensor Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmIoExpanderIO12CLEAR 1.3.6.1.4.1.17373.3.32767.0.23048
Climate Relay IO12 Sensor Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmIoExpanderIO13CLEAR 1.3.6.1.4.1.17373.3.32767.0.23049
Climate Relay IO13 Sensor Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmIoExpanderIO14CLEAR 1.3.6.1.4.1.17373.3.32767.0.23050
Climate Relay IO14 Sensor Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmIoExpanderIO15CLEAR 1.3.6.1.4.1.17373.3.32767.0.23051
Climate Relay IO15 Sensor Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmIoExpanderIO16CLEAR 1.3.6.1.4.1.17373.3.32767.0.23052
Climate Relay IO16 Sensor Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmIoExpanderIO17CLEAR 1.3.6.1.4.1.17373.3.32767.0.23053
Climate Relay IO17 Sensor Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmIoExpanderIO18CLEAR 1.3.6.1.4.1.17373.3.32767.0.23054
Climate Relay IO18 Sensor Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmIoExpanderIO19CLEAR 1.3.6.1.4.1.17373.3.32767.0.23055
Climate Relay IO19 Sensor Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmIoExpanderIO20CLEAR 1.3.6.1.4.1.17373.3.32767.0.23056
Climate Relay IO20 Sensor Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmIoExpanderIO21CLEAR 1.3.6.1.4.1.17373.3.32767.0.23057
Climate Relay IO21 Sensor Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmIoExpanderIO22CLEAR 1.3.6.1.4.1.17373.3.32767.0.23058
Climate Relay IO22 Sensor Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmIoExpanderIO23CLEAR 1.3.6.1.4.1.17373.3.32767.0.23059
Climate Relay IO23 Sensor Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmIoExpanderIO24CLEAR 1.3.6.1.4.1.17373.3.32767.0.23060
Climate Relay IO24 Sensor Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmIoExpanderIO25CLEAR 1.3.6.1.4.1.17373.3.32767.0.23061
Climate Relay IO25 Sensor Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmIoExpanderIO26CLEAR 1.3.6.1.4.1.17373.3.32767.0.23062
Climate Relay IO26 Sensor Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmIoExpanderIO27CLEAR 1.3.6.1.4.1.17373.3.32767.0.23063
Climate Relay IO27 Sensor Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmIoExpanderIO28CLEAR 1.3.6.1.4.1.17373.3.32767.0.23064
Climate Relay IO28 Sensor Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmIoExpanderIO29CLEAR 1.3.6.1.4.1.17373.3.32767.0.23065
Climate Relay IO29 Sensor Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmIoExpanderIO30CLEAR 1.3.6.1.4.1.17373.3.32767.0.23066
Climate Relay IO30 Sensor Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmIoExpanderIO31CLEAR 1.3.6.1.4.1.17373.3.32767.0.23067
Climate Relay IO31 Sensor Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmIoExpanderIO32CLEAR 1.3.6.1.4.1.17373.3.32767.0.23068
Climate Relay IO32 Sensor Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmT3hdSensorIntTempCCLEAR 1.3.6.1.4.1.17373.3.32767.0.23106
T3HD - Internal Temperature C Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmT3hdSensorIntTempFCLEAR 1.3.6.1.4.1.17373.3.32767.0.23107
T3HD - Internal Temperature F Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmT3hdSensorIntHumidityCLEAR 1.3.6.1.4.1.17373.3.32767.0.23108
T3HD - Internal Humidity Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmT3hdSensorIntDewPointCCLEAR 1.3.6.1.4.1.17373.3.32767.0.23109
T3HD - Internal Dew Point C Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmT3hdSensorIntDewPointFCLEAR 1.3.6.1.4.1.17373.3.32767.0.23110
T3HD - Internal Dew Point F Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmT3hdSensorExt1TempCCLEAR 1.3.6.1.4.1.17373.3.32767.0.23113
T3HD - External 1 Temperature C Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmT3hdSensorExt1TempFCLEAR 1.3.6.1.4.1.17373.3.32767.0.23114
T3HD - External 1 Temperature F Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmT3hdSensorExt2TempCCLEAR 1.3.6.1.4.1.17373.3.32767.0.23117
T3HD - External 2 Temperature C Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmT3hdSensorExt2TempFCLEAR 1.3.6.1.4.1.17373.3.32767.0.23118
T3HD - External 2 Temperature F Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmThdSensorTempCCLEAR 1.3.6.1.4.1.17373.3.32767.0.23205
THD - Temperature C Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmThdSensorTempFCLEAR 1.3.6.1.4.1.17373.3.32767.0.23206
THD - Temperature F Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmThdSensorHumidityCLEAR 1.3.6.1.4.1.17373.3.32767.0.23207
THD - Humidity Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmThdSensorDewPointCCLEAR 1.3.6.1.4.1.17373.3.32767.0.23208
THD - Dew Point C Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmThdSensorDewPointFCLEAR 1.3.6.1.4.1.17373.3.32767.0.23209
THD - Dew Point F Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmPos60VdcSensorVoltageCLEAR 1.3.6.1.4.1.17373.3.32767.0.23305
60Vdc Sensor Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl2CirTotkWattHrsTotCLEAR 1.3.6.1.4.1.17373.3.32767.0.23405
Kilo Watt Hours Total Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl2CirTotVoltsTotCLEAR 1.3.6.1.4.1.17373.3.32767.0.23406
Volts Total Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl2CirTotVoltPeakTotCLEAR 1.3.6.1.4.1.17373.3.32767.0.23407
Volts Peak Total Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl2CirTotDeciAmpsTotCLEAR 1.3.6.1.4.1.17373.3.32767.0.23408
Deciamps Total Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl2CirTotDeciAmpsPeakTotCLEAR 1.3.6.1.4.1.17373.3.32767.0.23409
Deciamps Peak Total Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl2CirTotRealPowerTotCLEAR 1.3.6.1.4.1.17373.3.32767.0.23410
Real Power Total Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl2CirTotApparentPowerTotCLEAR 1.3.6.1.4.1.17373.3.32767.0.23411
Apparent Power Total Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl2CirTotPowerFactorTotCLEAR 1.3.6.1.4.1.17373.3.32767.0.23412
Power Factor Total Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl2CirTotkWattHrsACLEAR 1.3.6.1.4.1.17373.3.32767.0.23413
Kilo Watt Hours A Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl2CirTotVoltsACLEAR 1.3.6.1.4.1.17373.3.32767.0.23414
Volts A Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl2CirTotVoltPeakACLEAR 1.3.6.1.4.1.17373.3.32767.0.23415
Volts Peak A Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl2CirTotDeciAmpsACLEAR 1.3.6.1.4.1.17373.3.32767.0.23416
Deciamps A Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl2CirTotDeciAmpsPeakACLEAR 1.3.6.1.4.1.17373.3.32767.0.23417
Deciamps Peak A Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl2CirTotRealPowerACLEAR 1.3.6.1.4.1.17373.3.32767.0.23418
Real Power A Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl2CirTotApparentPowerACLEAR 1.3.6.1.4.1.17373.3.32767.0.23419
Apparent Power A Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl2CirTotPowerFactorACLEAR 1.3.6.1.4.1.17373.3.32767.0.23420
Power Factor A Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl2CirTotkWattHrsBCLEAR 1.3.6.1.4.1.17373.3.32767.0.23421
Kilo Watt Hours B Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl2CirTotVoltsBCLEAR 1.3.6.1.4.1.17373.3.32767.0.23422
Volts B Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl2CirTotVoltPeakBCLEAR 1.3.6.1.4.1.17373.3.32767.0.23423
Volts Peak B Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl2CirTotDeciAmpsBCLEAR 1.3.6.1.4.1.17373.3.32767.0.23424
Deciamps B Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl2CirTotDeciAmpsPeakBCLEAR 1.3.6.1.4.1.17373.3.32767.0.23425
Deciamps Peak B Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl2CirTotRealPowerBCLEAR 1.3.6.1.4.1.17373.3.32767.0.23426
Real Power B Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl2CirTotApparentPowerBCLEAR 1.3.6.1.4.1.17373.3.32767.0.23427
Apparent Power B Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmCtrl2CirTotPowerFactorBCLEAR 1.3.6.1.4.1.17373.3.32767.0.23428
Power Factor B Clear Trap
Status: current Access: read-create
NOTIFICATION-TYPE    

cmSc10ControlModeCLEAR 1.3.6.1.4.1.17373.3.32767.0.23505
SC10 Control Mode Sensor Clear
Status: current Access: read-create
NOTIFICATION-TYPE    

cmSc10SetpointCCLEAR 1.3.6.1.4.1.17373.3.32767.0.23506
SC10 Temp Set Point Sensor Clear
Status: current Access: read-create
NOTIFICATION-TYPE    

cmSc10SetpointFCLEAR 1.3.6.1.4.1.17373.3.32767.0.23507
SC10 Temp Set Point Sensor Clear
Status: current Access: read-create
NOTIFICATION-TYPE    

cmSc10TempCCLEAR 1.3.6.1.4.1.17373.3.32767.0.23508
SC10 Internal Temp Sensor Clear
Status: current Access: read-create
NOTIFICATION-TYPE    

cmSc10TempFCLEAR 1.3.6.1.4.1.17373.3.32767.0.23509
SC10 Internal Temp Sensor Clear
Status: current Access: read-create
NOTIFICATION-TYPE    

cmSc10CapacityCLEAR 1.3.6.1.4.1.17373.3.32767.0.23510
SC10 Fan Speed Sensor Clear
Status: current Access: read-create
NOTIFICATION-TYPE