IEEE8021-PFC-MIB

File: IEEE8021-PFC-MIB.mib (5889 bytes)

Imported modules

SNMPv2-SMI IEEE8021-TC-MIB SNMPv2-CONF
IF-MIB SNMPv2-MIB

Imported symbols

MODULE-IDENTITY OBJECT-TYPE Counter32
Unsigned32 ieee802dot1mibs MODULE-COMPLIANCE
OBJECT-GROUP ifEntry ifGeneralInformationGroup
systemGroup

Defined Types

Ieee8021PfcIfEntry  
SEQUENCE    
  ieee8021PfcLinkDelayAllowance Unsigned32
  ieee8021PfcRequests Counter32
  ieee8021PfcIndications Counter32

Defined Values

ieee8021PFCMib 1.3.111.2.802.1.1.21
Priority-based Flow Control module for IEEE 802.1Q. Unless otherwise indicated, the references in this MIB module are to IEEE Std 802.1Q-2014. Copyright (C) IEEE (2014). This version of this MIB module is part of IEEE802.1Q; see the draft itself for full legal notices.
MODULE-IDENTITY    

ieee8021PfcMIBObjects 1.3.111.2.802.1.1.21.1
OBJECT IDENTIFIER    

ieee8021PfcConformance 1.3.111.2.802.1.1.21.2
OBJECT IDENTIFIER    

ieee8021PfcIfTable 1.3.111.2.802.1.1.21.1.1
A table of PFC information for all interfaces of a system.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Ieee8021PfcIfEntry

ieee8021PfcIfEntry 1.3.111.2.802.1.1.21.1.1.1
Each entry contains information about the PFC function on a single interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  Ieee8021PfcIfEntry  

ieee8021PfcLinkDelayAllowance 1.3.111.2.802.1.1.21.1.1.1.1
The allowance made for round-trip propagation delay of the link in bits. The value of this object MUST be retained across reinitializations of the management system.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

ieee8021PfcRequests 1.3.111.2.802.1.1.21.1.1.1.2
A count of the invoked PFC M_CONTROL.request primitives. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ieee8021PfcIndications 1.3.111.2.802.1.1.21.1.1.1.3
A count of the received PFC M_CONTROL.indication primitives. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

ieee8021PfcCompliances 1.3.111.2.802.1.1.21.2.1
OBJECT IDENTIFIER    

ieee8021PfcGroups 1.3.111.2.802.1.1.21.2.2
OBJECT IDENTIFIER    

ieee8021PfcGlobalReqdGroup 1.3.111.2.802.1.1.21.2.2.1
Objects in the global required group.
Status: current Access: read-only
OBJECT-GROUP    

ieee8021PfcCompliance 1.3.111.2.802.1.1.21.2.1.1
The compliance statement for support by a system of the IEEE8021-PFC-MIB module.
Status: current Access: read-only
MODULE-COMPLIANCE