IBM-RXR-MIB
File:
IBM-RXR-MIB.mib (97154 bytes)
Imported modules
Imported symbols
Defined Types
Rxr1dBasePortEntry |
|
SEQUENCE |
|
|
|
|
rxr1dBasePort |
INTEGER |
|
|
rxr1dBasePortIfIndex |
INTEGER |
|
|
rxr1dBasePortCircuit |
OBJECT IDENTIFIER |
|
|
rxr1dBasePortDelayExceededDiscards |
Counter |
|
|
rxr1dBasePortMtuExceededDiscards |
Counter |
|
Rxr1dStpPortEntry |
|
SEQUENCE |
|
|
|
|
rxr1dStpPort |
INTEGER |
|
|
rxr1dStpPortPriority |
INTEGER |
|
|
rxr1dStpPortState |
INTEGER |
|
|
rxr1dStpPortEnable |
INTEGER |
|
|
rxr1dStpPortPathCost |
INTEGER |
|
|
rxr1dStpPortDesignatedRoot |
BridgeId |
|
|
rxr1dStpPortDesignatedCost |
INTEGER |
|
|
rxr1dStpPortDesignatedBridge |
BridgeId |
|
|
rxr1dStpPortDesignatedPort |
OCTET STRING |
|
|
rxr1dStpPortForwardTransitions |
Counter |
|
Rxr1dSrPortEntry |
|
SEQUENCE |
|
|
|
|
rxr1dSrPort |
INTEGER |
|
|
rxr1dSrPortHopCount |
INTEGER |
|
|
rxr1dSrPortLocalSegment |
INTEGER |
|
|
rxr1dSrPortBridgeNum |
INTEGER |
|
|
rxr1dSrPortTargetSegment |
INTEGER |
|
|
rxr1dSrPortLargestFrame |
INTEGER |
|
|
rxr1dSrPortSTESpanMode |
INTEGER |
|
|
rxr1dSrPortSpecInFrames |
Counter |
|
|
rxr1dSrPortSpecOutFrames |
Counter |
|
|
rxr1dSrPortApeInFrames |
Counter |
|
|
rxr1dSrPortApeOutFrames |
Counter |
|
|
rxr1dSrPortSteInFrames |
Counter |
|
|
rxr1dSrPortSteOutFrames |
Counter |
|
|
rxr1dSrPortSegmentMismatchDiscards |
Counter |
|
|
rxr1dSrPortDuplicateSegmentDiscards |
Counter |
|
|
rxr1dSrPortHopCountExceededDiscards |
Counter |
|
Rxr1dTpFdbEntry |
|
SEQUENCE |
|
|
|
|
rxr1dTpFdbAddress |
MacAddress |
|
|
rxr1dTpFdbPort |
INTEGER |
|
|
rxr1dTpFdbStatus |
INTEGER |
|
Rxr1dTpPortEntry |
|
SEQUENCE |
|
|
|
|
rxr1dTpPort |
INTEGER |
|
|
rxr1dTpPortMaxInfo |
INTEGER |
|
|
rxr1dTpPortInFrames |
Counter |
|
|
rxr1dTpPortOutFrames |
Counter |
|
|
rxr1dTpPortInDiscards |
Counter |
|
Rxr1dStaticEntry |
|
SEQUENCE |
|
|
|
|
rxr1dStaticAddress |
MacAddress |
|
|
rxr1dStaticReceivePort |
INTEGER |
|
|
rxr1dStaticAllowedToGoTo |
OCTET STRING |
|
|
rxr1dStaticStatus |
INTEGER |
|
IPXSysEntry |
|
SEQUENCE |
|
|
|
|
ipxSysInstance |
INTEGER |
|
|
ipxSysExistState |
INTEGER |
|
|
ipxSysIntNetNumExists |
INTEGER |
|
|
ipxSysIntNetNum |
NetNumber |
|
|
ipxSysName |
OCTET STRING |
|
|
ipxSysMaxPathSplits |
INTEGER |
|
|
ipxSysMaxHops |
INTEGER |
|
|
ipxSysVersionMajor |
INTEGER |
|
|
ipxSysVersionMinor |
INTEGER |
|
|
ipxSysInReceives |
Counter |
|
|
ipxSysInTooManyHops |
Counter |
|
|
ipxSysInHdrErrors |
Counter |
|
|
ipxSysInUnknownSockets |
Counter |
|
|
ipxSysInFiltered |
Counter |
|
|
ipxSysInCompressDiscards |
Counter |
|
|
ipxSysInDiscards |
Counter |
|
|
ipxSysInDelivers |
Counter |
|
|
ipxSysNETBIOSPackets |
Counter |
|
|
ipxSysForwPackets |
Counter |
|
|
ipxSysOutRequests |
Counter |
|
|
ipxSysOutNoRoutes |
Counter |
|
|
ipxSysOutFiltered |
Counter |
|
|
ipxSysOutCompressDiscards |
Counter |
|
|
ipxSysOutMalformedRequests |
Counter |
|
|
ipxSysOutDiscards |
Counter |
|
|
ipxSysOutPackets |
Counter |
|
|
ipxSysCircCount |
Counter |
|
|
ipxSysDestCount |
Counter |
|
|
ipxSysServCount |
Counter |
|
|
ipxSysResourceFailures |
Counter |
|
|
ipxSysConfigSockets |
Counter |
|
|
ipxSysMaxOpenSockets |
Counter |
|
|
ipxSysOpenSocketFails |
Counter |
|
IPXCircEntry |
|
SEQUENCE |
|
|
|
|
ipxCircSysInstance |
INTEGER |
|
|
ipxCircIndex |
INTEGER |
|
|
ipxCircExistState |
INTEGER |
|
|
ipxCircOperState |
INTEGER |
|
|
ipxCircIfIndex |
NetNumber |
|
|
ipxCircName |
OCTET STRING |
|
|
ipxCircInfo |
OCTET STRING |
|
|
ipxCircType |
INTEGER |
|
|
ipxCircLocalMaxPacketSize |
INTEGER |
|
|
ipxCircCompressState |
INTEGER |
|
|
ipxCircCompressSlots |
INTEGER |
|
|
ipxCircCompressedSent |
INTEGER |
|
|
ipxCircUncompressedSent |
INTEGER |
|
|
ipxCircMediaType |
INTEGER |
|
|
ipxCircNetNumber |
NetNumber |
|
|
ipxCircStateChanges |
Counter |
|
|
ipxCircInitFails |
Counter |
|
|
ipxCircDelay |
INTEGER |
|
|
ipxCircThroughput |
INTEGER |
|
IPXDestEntry |
|
SEQUENCE |
|
|
|
|
ipxDestSysInstance |
INTEGER |
|
|
ipxDestNetNum |
NetNumber |
|
|
ipxDestProtocol |
INTEGER |
|
|
ipxDestCost |
INTEGER |
|
|
ipxDestHopCount |
INTEGER |
|
|
ipxDestNextHopCircIndex |
INTEGER |
|
|
ipxDestNextHopNICAddress |
OCTET STRING |
|
|
ipxDestNextHopNetNum |
NetNumber |
|
|
ipxDestType |
INTEGER |
|
IPXServEntry |
|
SEQUENCE |
|
|
|
|
ipxServSysInstance |
INTEGER |
|
|
ipxServName |
OCTET STRING |
|
|
ipxServTypeValue |
OCTET STRING |
|
|
ipxServType |
INTEGER |
|
|
ipxServProtocol |
INTEGER |
|
|
ipxServNetNum |
NetNumber |
|
|
ipxServNode |
OCTET STRING |
|
|
ipxServSocket |
OCTET STRING |
|
IPXDestServEntry |
|
SEQUENCE |
|
|
|
|
ipxDestServSysInstance |
INTEGER |
|
|
ipxDestServNetNum |
NetNumber |
|
|
ipxDestServNode |
OCTET STRING |
|
|
ipxDestServSocket |
OCTET STRING |
|
|
ipxDestServName |
OCTET STRING |
|
|
ipxDestServTypeValue |
OCTET STRING |
|
|
ipxDestServType |
INTEGER |
|
|
ipxDestServProtocol |
INTEGER |
|
RIPSAPSysEntry |
|
SEQUENCE |
|
|
|
|
ripsapSysInstance |
INTEGER |
|
|
ripsapSysRIPState |
INTEGER |
|
|
ripsapSysRIPIncorrectPackets |
Counter |
|
|
ripsapSysSAPState |
INTEGER |
|
|
ripsapSysSAPIncorrectPackets |
Counter |
|
RIPSAPCircEntry |
|
SEQUENCE |
|
|
|
|
ripsapCircSysInstance |
INTEGER |
|
|
ripsapCircIndex |
INTEGER |
|
|
ripsapCircRIPState |
INTEGER |
|
|
ripsapCircRIPPace |
INTEGER |
|
|
ripsapCircRIPUpdate |
INTEGER |
|
|
ripsapCircRIPAgeMultiplier |
INTEGER |
|
|
ripsapCircRIPPacketSize |
INTEGER |
|
|
ripsapCircRIPOutPackets |
Counter |
|
|
ripsapCircRIPInPackets |
Counter |
|
|
ripsapCircSAPState |
INTEGER |
|
|
ripsapCircSAPPace |
INTEGER |
|
|
ripsapCircSAPUpdate |
INTEGER |
|
|
ripsapCircSAPAgeMultiplier |
INTEGER |
|
|
ripsapCircSAPGetNearestServerReply |
INTEGER |
|
|
ripsapCircSAPPacketSize |
INTEGER |
|
|
ripsapCircSAPOutPackets |
Counter |
|
|
ripsapCircSAPInPackets |
Counter |
|
Defined Values
ibm |
1.3.6.1.4.1.2 |
OBJECT IDENTIFIER |
|
|
|
ibmProd |
1.3.6.1.4.1.2.6 |
OBJECT IDENTIFIER |
|
|
|
rxr1dBase |
1.3.6.1.4.1.2.6.26.1.1 |
OBJECT IDENTIFIER |
|
|
|
rxr1dStp |
1.3.6.1.4.1.2.6.26.1.2 |
OBJECT IDENTIFIER |
|
|
|
rxr1dSr |
1.3.6.1.4.1.2.6.26.1.3 |
OBJECT IDENTIFIER |
|
|
|
rxr1dTp |
1.3.6.1.4.1.2.6.26.1.4 |
OBJECT IDENTIFIER |
|
|
|
rxr1dBaseBridgeAddress |
1.3.6.1.4.1.2.6.26.1.1.1 |
The MAC address used by this bridge when it must
be referred to in a unique fashion. It is
recommended that this be the numerically smallest
MAC address of all ports that belong to this
bridge. However it is only required to be unique.
When concatenated with rxr1dStpPriority a unique
BridgeIdentifier is formed which is used in the
Spanning Tree Protocol. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
MacAddress |
|
|
rxr1dBaseNumPorts |
1.3.6.1.4.1.2.6.26.1.1.2 |
The number of ports controlled by this bridging
entity. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
rxr1dBaseType |
1.3.6.1.4.1.2.6.26.1.1.3 |
Indicates what type of bridging this bridge can
perform. If a bridge is actually performing a
certain type of bridging this will be indicated by
entries in the port table for the given type. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
unknown(1), transparent-only(2), sourceroute-only(3), srt(4) |
|
rxr1dBasePortTable |
1.3.6.1.4.1.2.6.26.1.1.4 |
A table that contains generic information about
every port that is associated with this bridge.
Transparent, source-route, and srt ports are
included. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
Rxr1dBasePortEntry |
|
rxr1dBasePortEntry |
1.3.6.1.4.1.2.6.26.1.1.4.1 |
A list of information for each port of the
bridge. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Rxr1dBasePortEntry |
|
|
rxr1dBasePort |
1.3.6.1.4.1.2.6.26.1.1.4.1.1 |
The port number of the port for which this entry
contains bridge management information. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
rxr1dBasePortIfIndex |
1.3.6.1.4.1.2.6.26.1.1.4.1.2 |
The value of the instance of the ifIndex object,
defined in [4,6], for the interface corresponding
to this port. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
rxr1dBasePortCircuit |
1.3.6.1.4.1.2.6.26.1.1.4.1.3 |
For a port which (potentially) has the same value
of rxr1dBasePortIfIndex as another port on the
same bridge, this object contains the name of an
object instance unique to this port. For example,
in the case where multiple ports correspond one-
to-one with multiple X.25 virtual circuits, this
value might identify an (e.g., the first) object
instance associated with the X.25 virtual circuit
corresponding to this port.
For a port which has a unique value of
rxr1dBasePortIfIndex, this object can have the
value { 0 0 }. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OBJECT IDENTIFIER |
|
|
rxr1dBasePortDelayExceededDiscards |
1.3.6.1.4.1.2.6.26.1.1.4.1.4 |
The number of frames discarded by this port due
to excessive transit delay through the bridge. It
is incremented by both transparent and source
route bridges. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter |
|
|
rxr1dBasePortMtuExceededDiscards |
1.3.6.1.4.1.2.6.26.1.1.4.1.5 |
The number of frames discarded by this port due
to an excessive size. It is incremented by both
transparent and source route bridges. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter |
|
|
rxr1dStpProtocolSpecification |
1.3.6.1.4.1.2.6.26.1.2.1 |
An indication of what version of the Spanning
Tree Protocol is being run. The value
'decLb100(2)' indicates the DEC LANbridge 100
Spanning Tree protocol. IEEE 802.1d
implementations will return 'ieee8021d(3)'. If
future versions of the IEEE Spanning Tree Protocol
are released that are incompatible with the
current version a new value will be defined. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
unknown(1), decLb100(2), ieee8021d(3) |
|
rxr1dStpPriority |
1.3.6.1.4.1.2.6.26.1.2.2 |
The value of the write-able portion of the Bridge
ID, i.e., the first two octets of the (8 octet
long) Bridge ID. The other (last) 6 octets of the
Bridge ID are given by the value of
rxr1dBaseBridgeAddress. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65535 |
|
rxr1dStpTimeSinceTopologyChange |
1.3.6.1.4.1.2.6.26.1.2.3 |
The time (in hundredths of a second) since the
last time a topology change was detected by the
bridge entity. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
TimeTicks |
|
|
rxr1dStpTopChanges |
1.3.6.1.4.1.2.6.26.1.2.4 |
The total number of topology changes detected by
this bridge since the management entity was last
reset or initialized. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter |
|
|
rxr1dStpDesignatedRoot |
1.3.6.1.4.1.2.6.26.1.2.5 |
The bridge identifier of the root of the spanning
tree as determined by the Spanning Tree Protocol
as executed by this node. This value is used as
the Root Identifier parameter in all Configuration
Bridge PDUs originated by this node. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
BridgeId |
|
|
rxr1dStpRootCost |
1.3.6.1.4.1.2.6.26.1.2.6 |
The cost of the path to the root as seen from
this bridge. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
rxr1dStpRootPort |
1.3.6.1.4.1.2.6.26.1.2.7 |
The port number of the port which offers the
lowest cost path from this bridge to the root
bridge. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
rxr1dStpMaxAge |
1.3.6.1.4.1.2.6.26.1.2.8 |
The maximum age of Spanning Tree Protocol
information learned from the network on any port
before it is discarded, in units of hundredths of
a second. This is the actual value that this
bridge is currently using. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Timeout |
|
|
rxr1dStpHelloTime |
1.3.6.1.4.1.2.6.26.1.2.9 |
The amount of time between the transmission of
Configuration bridge PDUs by this node on any port
when it is the root of the spanning tree or trying
to become so, in units of hundredths of a second.
This is the actual value that this bridge is
currently using. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Timeout |
|
|
rxr1dStpHoldTime |
1.3.6.1.4.1.2.6.26.1.2.10 |
This time value determines the interval length
during which no more than two Configuration bridge
PDUs shall be transmitted by this node, in units
of hundredths of a second. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
rxr1dStpForwardDelay |
1.3.6.1.4.1.2.6.26.1.2.11 |
This time value, measured in units of hundredths
of a second, controls how fast a port changes its
spanning state when moving towards the Forwarding
state. The value determines how long the port
stays in a particular state before moving to the
next state. For example, how long a port stays in
the Listening state when moving from Blocking to
Learning. This value is also used, when a
topology change has been detected and is underway,
to age all dynamic entries in the Forwarding
Database. [Note that this value is the one that
this bridge is currently using, in contrast to
rxr1dStpBridgeForwardDelay which is the value that
this bridge and all others would start using
if/when this bridge were to become the root.] |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Timeout |
|
|
rxr1dStpBridgeMaxAge |
1.3.6.1.4.1.2.6.26.1.2.12 |
The value that all bridges use for MaxAge when
this bridge is acting as the root. Note that
802.1d/D9 specifies that the range for this
parameter is related to the value of
rxr1dStpBridgeHelloTime. The granularity of this
timer is specified by 802.1d/D9 to be 1 second.
An agent may return a badValue error if a set is
attempted to a value which is not a whole number
of seconds. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Timeout |
600..4000 |
|
rxr1dStpBridgeHelloTime |
1.3.6.1.4.1.2.6.26.1.2.13 |
The value that all bridges use for HelloTime when
this bridge is acting as the root. The
granularity of this timer is specified by
802.1d/D9 to be 1 second. An agent may return a
badValue error if a set is attempted to a value
which is not a whole number of seconds. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Timeout |
100..1000 |
|
rxr1dStpBridgeForwardDelay |
1.3.6.1.4.1.2.6.26.1.2.14 |
The value that all bridges use for ForwardDelay
when this bridge is acting as the root. Note that
802.1d/D9 specifies that the range for this
parameter is related to the value of
rxr1dStpBridgeMaxAge. The granularity of this
timer is specified by 802.1d/D9 to be 1 second.
An agent may return a badValue error if a set is
attempted to a value which is not a whole number
of seconds. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Timeout |
400..3000 |
|
rxr1dStpPortTable |
1.3.6.1.4.1.2.6.26.1.2.15 |
A table that contains port-specific information
for the Spanning Tree Protocol. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
Rxr1dStpPortEntry |
|
rxr1dStpPortEntry |
1.3.6.1.4.1.2.6.26.1.2.15.1 |
A list of information maintained by every port
about the Spanning Tree Protocol state for that
port. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Rxr1dStpPortEntry |
|
|
rxr1dStpPort |
1.3.6.1.4.1.2.6.26.1.2.15.1.1 |
The port number of the port for which this entry
contains Spanning Tree Protocol management
information. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
rxr1dStpPortPriority |
1.3.6.1.4.1.2.6.26.1.2.15.1.2 |
The value of the priority field which is
contained in the first (in network byte order)
octet of the (2 octet long) Port ID. The other
octet of the Port ID is given by the value of
rxr1dStpPort. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..255 |
|
rxr1dStpPortState |
1.3.6.1.4.1.2.6.26.1.2.15.1.3 |
The port's current state as defined by
application of the Spanning Tree Protocol. This
state controls what action a port takes on
reception of a frame. If the bridge has detected
a port that is malfunctioning it will place that
port into the broken(6) state. For ports which
are disabled (see rxr1dStpPortEnable), this object
will have a value of disabled(1). |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
disabled(1), blocking(2), listening(3), learning(4), forwarding(5), broken(6) |
|
rxr1dStpPortEnable |
1.3.6.1.4.1.2.6.26.1.2.15.1.4 |
The enabled/disabled status of the port. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
enabled(1), disabled(2) |
|
rxr1dStpPortPathCost |
1.3.6.1.4.1.2.6.26.1.2.15.1.5 |
The contribution of this port to the path cost of
paths towards the spanning tree root which include
this port. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
1..65535 |
|
rxr1dStpPortDesignatedRoot |
1.3.6.1.4.1.2.6.26.1.2.15.1.6 |
The unique Bridge Identifier of the Bridge
recorded as the Root in the Configuration BPDUs
transmitted by the Designated Bridge for the
segment to which the port is attached. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
BridgeId |
|
|
rxr1dStpPortDesignatedCost |
1.3.6.1.4.1.2.6.26.1.2.15.1.7 |
The path cost of the Designated Port of the
segment connected to this port. This value is
compared to the Root Path Cost field in received
bridge PDUs. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
rxr1dStpPortDesignatedBridge |
1.3.6.1.4.1.2.6.26.1.2.15.1.8 |
The Bridge Identifier of the bridge which this
port considers to be the Designated Bridge for
this port's segment. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
BridgeId |
|
|
rxr1dStpPortDesignatedPort |
1.3.6.1.4.1.2.6.26.1.2.15.1.9 |
The Port Identifier of the port on the Designated
Bridge for this port's segment. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(2) |
|
rxr1dStpPortForwardTransitions |
1.3.6.1.4.1.2.6.26.1.2.15.1.10 |
The number of times this port has transitioned
from the Learning state to the Forwarding state. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter |
|
|
rxr1dSrPortTable |
1.3.6.1.4.1.2.6.26.1.3.1 |
A table that contains information about every
port that is associated with this source route
bridge. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
Rxr1dSrPortEntry |
|
rxr1dSrPortEntry |
1.3.6.1.4.1.2.6.26.1.3.1.1 |
A list of information for each port of a source
route bridge. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Rxr1dSrPortEntry |
|
|
rxr1dSrPort |
1.3.6.1.4.1.2.6.26.1.3.1.1.1 |
The port number of the port for which this entry
contains Source Route management information. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
rxr1dSrPortHopCount |
1.3.6.1.4.1.2.6.26.1.3.1.1.2 |
The maximum number of routing descriptors allowed
in an All Paths or Spanning Tree Explorer frames. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
rxr1dSrPortLocalSegment |
1.3.6.1.4.1.2.6.26.1.3.1.1.3 |
The segment number that uniquely identifies the
segment to which this port is connected. Current
source routing protocols limit this value to the
range: 0 through 4095. A value of 65535 signifies
that no segment number is assigned to this port. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
rxr1dSrPortBridgeNum |
1.3.6.1.4.1.2.6.26.1.3.1.1.4 |
A bridge number uniquely identifies a bridge when
more than one bridge is used to span the same two
segments. Current source routing protocols limit
this value to the range: 0 through 15. A value of
65535 signifies that no bridge number is assigned
to this bridge. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
rxr1dSrPortTargetSegment |
1.3.6.1.4.1.2.6.26.1.3.1.1.5 |
The segment number that corresponds to the target
segment this port is considered to be connected to
by the bridge. Current source routing protocols
limit this value to the range: 0 through 4095. A
value of 65535 signifies that no target segment is
assigned to this port. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
rxr1dSrPortLargestFrame |
1.3.6.1.4.1.2.6.26.1.3.1.1.6 |
The maximum size of the INFO field (LLC and
above) that this port can send/receive. It does
not include any MAC level (framing) octets. The
value of this object is used by this bridge to
determine whether a modification of the
LargestFrame (LF, see [14]) field of the Routing
Control field of the Routing Information Field is
necessary. Valid values as defined by the 802.5
source routing bridging specification[14] are 516,
1500, 2052, 4472, 8144, 11407, 17800, and 65535
octets. Behavior of the port when an illegal
value is written is implementation specific. It
is recommended that a reasonable legal value be
chosen. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
rxr1dSrMtu516(516), rxr1dSrMtu1500(1500), rxr1dSrMtu2052(2052), rxr1dSrMtu4472(4472), rxr1dSrMtu8144(8144), rxr1dSrMtu11407(11407), rxr1dSrMtu17800(17800), rxr1dSrMtu65535(65535) |
|
rxr1dSrPortSTESpanMode |
1.3.6.1.4.1.2.6.26.1.3.1.1.7 |
Determines how this port behaves when presented
with a Spanning Tree Explorer frame. The value
'disabled(2)' indicates that the port will not
accept or send Spanning Tree Explorer packets; any
STE packets received will be silently discarded.
The value 'forced(3)' indicates the port will
always accept and propagate Spanning Tree Explorer
frames. This allows a manually configured
Spanning Tree for this class of packet to be
configured. Note that unlike transparent bridging
this is not catastrophic to the network if there
are loops. The value 'auto-span(1)' can only be
returned by a bridge that both implements the
Spanning Tree Protocol and has use of the protocol
enabled on this port. The behavior of the port for
Spanning Tree Explorer frames is determined by the
state of rxr1dStpPortState. If the port is in the
'forwarding' state, the frame will be accepted or
propagated. Otherwise it will be silently
discarded. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
auto-span(1), disabled(2), forced(3) |
|
rxr1dSrPortSpecInFrames |
1.3.6.1.4.1.2.6.26.1.3.1.1.8 |
The number of specifically routed frames that
have been received from this port's segment. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter |
|
|
rxr1dSrPortSpecOutFrames |
1.3.6.1.4.1.2.6.26.1.3.1.1.9 |
The number of specifically routed frames that
this port has transmitted on its segment. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter |
|
|
rxr1dSrPortApeInFrames |
1.3.6.1.4.1.2.6.26.1.3.1.1.10 |
The number of all paths explorer frames that have
been received by this port from its segment. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter |
|
|
rxr1dSrPortApeOutFrames |
1.3.6.1.4.1.2.6.26.1.3.1.1.11 |
The number of all paths explorer frames that have
been transmitted by this port on its segment. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter |
|
|
rxr1dSrPortSteInFrames |
1.3.6.1.4.1.2.6.26.1.3.1.1.12 |
The number of spanning tree explorer frames that
have been received by this port from its segment. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter |
|
|
rxr1dSrPortSteOutFrames |
1.3.6.1.4.1.2.6.26.1.3.1.1.13 |
The number of spanning tree explorer frames that
have been transmitted by this port on its
segment. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter |
|
|
rxr1dSrPortSegmentMismatchDiscards |
1.3.6.1.4.1.2.6.26.1.3.1.1.14 |
The number of explorer frames that have been
discarded by this port because the routing
descriptor field contained an invalid adjacent
segment value. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter |
|
|
rxr1dSrPortDuplicateSegmentDiscards |
1.3.6.1.4.1.2.6.26.1.3.1.1.15 |
The number of frames that have been discarded by
this port because the routing descriptor field
contained a duplicate segment identifier. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter |
|
|
rxr1dSrPortHopCountExceededDiscards |
1.3.6.1.4.1.2.6.26.1.3.1.1.16 |
The number of explorer frames that have been
discarded by this port because the Routing
Information Field has exceeded the maximum route
descriptor length. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter |
|
|
rxr1dTpLearnedEntryDiscards |
1.3.6.1.4.1.2.6.26.1.4.1 |
The total number of Forwarding Database entries,
which have been or would have been learnt, but
have been discarded due to a lack of space to
store them in the Forwarding Database. If this
counter is increasing, it indicates that the
Forwarding Database is regularly becoming full (a
condition which has unpleasant performance effects
on the subnetwork). If this counter has a
significant value but is not presently increasing,
it indicates that the problem has been occurring
but is not persistent. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter |
|
|
rxr1dTpAgingTime |
1.3.6.1.4.1.2.6.26.1.4.2 |
The timeout period in seconds for aging out
dynamically learned forwarding information. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
rxr1dTpFdbTable |
1.3.6.1.4.1.2.6.26.1.4.3 |
A table that contains information about unicast
entries for which the bridge has forwarding and/or
filtering information. This information is used
by the transparent bridging function in
determining how to propagate a received frame. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
Rxr1dTpFdbEntry |
|
rxr1dTpFdbEntry |
1.3.6.1.4.1.2.6.26.1.4.3.1 |
Information about a specific unicast MAC address
for which the bridge has some forwarding and/or
filtering information. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Rxr1dTpFdbEntry |
|
|
rxr1dTpFdbAddress |
1.3.6.1.4.1.2.6.26.1.4.3.1.1 |
A unicast MAC address for which the bridge has
forwarding and/or filtering information. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
MacAddress |
|
|
rxr1dTpFdbPort |
1.3.6.1.4.1.2.6.26.1.4.3.1.2 |
Either the value '0', or the port number of the
port on which a frame having a source address
equal to the value of the corresponding instance
of rxr1dTpFdbAddress has been seen. A value of
'0' indicates that the port number has not been
learned but that the bridge does have some
forwarding/filtering information about this
address (e.g. in the rxr1dStaticTable).
Implementors are encouraged to assign the port
value to this object whenever it is learned even
for addresses for which the corresponding value of
rxr1dTpFdbStatus is not learned(3). |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
rxr1dTpFdbStatus |
1.3.6.1.4.1.2.6.26.1.4.3.1.3 |
The status of this entry. The meanings of the
values are:
other(1) : none of the following. This would
include the case where some other
MIB object (not the corresponding
instance of rxr1dTpFdbPort, nor an
entry in the rxr1dStaticTable) is
being used to determine if and how
frames addressed to the value of
the corresponding instance of
rxr1dTpFdbAddress are being
forwarded.
invalid(2) : this entry is not longer valid
(e.g., it was learned but has since
aged-out), but has not yet been
flushed from the table.
learned(3) : the value of the corresponding
instance of rxr1dTpFdbPort was
learned, and is being used.
self(4) : the value of the corresponding
instance of rxr1dTpFdbAddress
represents one of the bridge's
addresses. The corresponding
instance of rxr1dTpFdbPort
indicates which of the bridge's
ports has this address.
mgmt(5) : the value of the corresponding
instance of rxr1dTpFdbAddress is
also the value of an existing
instance of rxr1dStaticAddress. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
other(1), invalid(2), learned(3), self(4), mgmt(5) |
|
rxr1dTpPortTable |
1.3.6.1.4.1.2.6.26.1.4.4 |
A table that contains information about every
port that is associated with this transparent
bridge. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
Rxr1dTpPortEntry |
|
rxr1dTpPortEntry |
1.3.6.1.4.1.2.6.26.1.4.4.1 |
A list of information for each port of a
transparent bridge. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Rxr1dTpPortEntry |
|
|
rxr1dTpPort |
1.3.6.1.4.1.2.6.26.1.4.4.1.1 |
The port number of the port for which this entry
contains Transparent bridging management
information. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
rxr1dTpPortMaxInfo |
1.3.6.1.4.1.2.6.26.1.4.4.1.2 |
The maximum size of the INFO (non-MAC) field that
this port will receive or transmit. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
rxr1dTpPortInFrames |
1.3.6.1.4.1.2.6.26.1.4.4.1.3 |
The number of frames that have been received by
this port from its segment. Note that a frame
received on the interface corresponding to this
port is only counted by this object if and only if
it is for a protocol being processed by the local
bridging function. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter |
|
|
rxr1dTpPortOutFrames |
1.3.6.1.4.1.2.6.26.1.4.4.1.4 |
The number of frames that have been transmitted
by this port to its segment. Note that a frame
transmitted on the interface corresponding to this
port is only counted by this object if and only if
it is for a protocol being processed by the local
bridging function. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter |
|
|
rxr1dTpPortInDiscards |
1.3.6.1.4.1.2.6.26.1.4.4.1.5 |
Count of valid frames received which were
discarded (i.e., filtered) by the Forwarding
Process. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter |
|
|
rxr1dStaticTable |
1.3.6.1.4.1.2.6.26.1.5.1 |
A table containing filtering information
configured into the bridge by (local or network)
management specifying the set of ports to which
frames received from specific ports and containing
specific destination addresses are allowed to be
forwarded. The value of zero in this table as the
port number from which frames with a specific
destination address are received, is used to
specify all ports for which there is no specific
entry in this table for that particular
destination address. Entries are valid for
unicast and for group/broadcast addresses. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
Rxr1dStaticEntry |
|
rxr1dStaticEntry |
1.3.6.1.4.1.2.6.26.1.5.1.1 |
Filtering information configured into the bridge
by (local or network) management specifying the
set of ports to which frames received from a
specific port and containing a specific
destination address are allowed to be forwarded. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
Rxr1dStaticEntry |
|
|
rxr1dStaticAddress |
1.3.6.1.4.1.2.6.26.1.5.1.1.1 |
The destination MAC address in a frame to which
this entry's filtering information applies. This
object can take the value of a unicast address, a
group address or the broadcast address. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
MacAddress |
|
|
rxr1dStaticReceivePort |
1.3.6.1.4.1.2.6.26.1.5.1.1.2 |
Either the value '0', or the port number of the
port from which a frame must be received in order
for this entry's filtering information to apply.
A value of zero indicates that this entry applies
on all ports of the bridge for which there is no
other applicable entry. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
rxr1dStaticAllowedToGoTo |
1.3.6.1.4.1.2.6.26.1.5.1.1.3 |
The set of ports to which frames received from a
specific port and destined for a specific MAC
address, are allowed to be forwarded. Each octet
within the value of this object specifies a set of
eight ports, with the first octet specifying ports
1 through 8, the second octet specifying ports 9
through 16, etc. Within each octet, the most
significant bit represents the lowest numbered
port, and the least significant bit represents the
highest numbered port. Thus, each port of the
bridge is represented by a single bit within the
value of this object. If that bit has a value of
'1' then that port is included in the set of
ports; the port is not included if its bit has a
value of '0'. (Note that the setting of the bit
corresponding to the port from which a frame is
received is irrelevant.) |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
rxr1dStaticStatus |
1.3.6.1.4.1.2.6.26.1.5.1.1.4 |
This object indicates the status of this entry.
other(1) - this entry is currently in use but
the conditions under which it will
remain so are different from each of the
following values.
invalid(2) - writing this value to the object
removes the corresponding entry.
permanent(3) - this entry is currently in use
and will remain so after the next reset
of the bridge.
deleteOnReset(4) - this entry is currently in
use and will remain so until the next
reset of the bridge.
deleteOnTimeout(5) - this entry is currently
in use and will remain so until it is
aged out. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
other(1), invalid(2), permanent(3), deleteOnReset(4), deleteOnTimeout(5) |
|
newRoot |
1 |
The newRoot trap indicates that the sending agent
has become the new root of the Spanning Tree; the
trap is sent by a bridge soon after its election
as the new root, e.g., upon expiration of the
Topology Change Timer immediately subsequent to
its election. |
TRAP-TYPE |
|
|
|
topologyChange |
2 |
A topologyChange trap is sent by a bridge when
any of its configured ports transitions from the
Learning state to the Forwarding state, or from
the Forwarding state to the Blocking state. The
trap is not sent if a newRoot trap is sent for the
same transition. |
TRAP-TYPE |
|
|
|
ipx |
1.3.6.1.4.1.2.6.26.2.1 |
OBJECT IDENTIFIER |
|
|
|
ipxSystem |
1.3.6.1.4.1.2.6.26.2.1.1 |
OBJECT IDENTIFIER |
|
|
|
ipxCircuit |
1.3.6.1.4.1.2.6.26.2.1.2 |
OBJECT IDENTIFIER |
|
|
|
ipxSysTable |
1.3.6.1.4.1.2.6.26.2.1.1.1 |
The IPX System table. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
IPXSysEntry |
|
ipxSysEntry |
1.3.6.1.4.1.2.6.26.2.1.1.1.1 |
Each entry corresponds to one instance of IPX running
on the system. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
IPXSysEntry |
|
|
ipxSysInstance |
1.3.6.1.4.1.2.6.26.2.1.1.1.1.1 |
The unique identifier of the instance of IPX to which this
row corresponds. This value may be written only when
creating a new entry in the table. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
ipxSysExistState |
1.3.6.1.4.1.2.6.26.2.1.1.1.1.2 |
The validity of this entry in the IPX system table.
Setting this field to off indicates that this entry may be
deleted from the system table at the IPX implemntation's
discretion. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
off(1), on(2) |
|
ipxSysIntNetNumExists |
1.3.6.1.4.1.2.6.26.2.1.1.1.1.3 |
Indicates whether this instance of IPX has an internal
network number. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
no(1), yes(2) |
|
ipxSysIntNetNum |
1.3.6.1.4.1.2.6.26.2.1.1.1.1.4 |
The IPX internal network number of this instance of IPX.
This value is undefined if the value of
ipxSysIntNetNumExists is no. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
NetNumber |
|
|
ipxSysName |
1.3.6.1.4.1.2.6.26.2.1.1.1.1.5 |
The readable name for this system. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(0..48) |
|
ipxSysMaxPathSplits |
1.3.6.1.4.1.2.6.26.2.1.1.1.1.6 |
The maximum number of paths with equal routing metric
value which this instance of IPX may split
between when forwarding packets. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
ipxSysMaxHops |
1.3.6.1.4.1.2.6.26.2.1.1.1.1.7 |
The maximum number of hops a packet may take. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
ipxSysVersionMajor |
1.3.6.1.4.1.2.6.26.2.1.1.1.1.8 |
The major version of IPX supported. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
ipxSysVersionMinor |
1.3.6.1.4.1.2.6.26.2.1.1.1.1.9 |
The minor version of IPX supported. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
ipxSysInReceives |
1.3.6.1.4.1.2.6.26.2.1.1.1.1.10 |
The total number of IPX packets received, including
those received in error. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter |
|
|
ipxSysInTooManyHops |
1.3.6.1.4.1.2.6.26.2.1.1.1.1.11 |
The number of IPX packets discarded due to exceeding the
maximum hop count. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter |
|
|
ipxSysInHdrErrors |
1.3.6.1.4.1.2.6.26.2.1.1.1.1.12 |
The number of IPX packets discarded due to errors in
their headers, including ant IPX packet with a size less
than the minimum of 30 bytes. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter |
|
|
ipxSysInUnknownSockets |
1.3.6.1.4.1.2.6.26.2.1.1.1.1.13 |
The number of IPX packets discarded because the
destination socket was not open. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter |
|
|
ipxSysInFiltered |
1.3.6.1.4.1.2.6.26.2.1.1.1.1.14 |
The number of incoming IPX packets discarded due to
filtering. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter |
|
|
ipxSysInCompressDiscards |
1.3.6.1.4.1.2.6.26.2.1.1.1.1.15 |
The number of incoming IPX packets discarded due to
decompression errors. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter |
|
|
ipxSysInDiscards |
1.3.6.1.4.1.2.6.26.2.1.1.1.1.16 |
The number of IPX packets received but discarded due to
processing decision. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter |
|
|
ipxSysInDelivers |
1.3.6.1.4.1.2.6.26.2.1.1.1.1.17 |
The total number of IPX packets delivered locally,
including packets from local applications. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter |
|
|
ipxSysNETBIOSPackets |
1.3.6.1.4.1.2.6.26.2.1.1.1.1.18 |
The total number of NetBIOS packets received. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter |
|
|
ipxSysForwPackets |
1.3.6.1.4.1.2.6.26.2.1.1.1.1.19 |
The number of IPX packets forwarded. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter |
|
|
ipxSysOutRequests |
1.3.6.1.4.1.2.6.26.2.1.1.1.1.20 |
The number of IPX packets supplied locally for
transmission, not including any packets counted in
ipxForwPackets. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter |
|
|
ipxSysOutNoRoutes |
1.3.6.1.4.1.2.6.26.2.1.1.1.1.21 |
The number of IPX packets discarded because no route was
found. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter |
|
|
ipxSysOutFiltered |
1.3.6.1.4.1.2.6.26.2.1.1.1.1.22 |
The number of outgoing IPX packets discarded due to
filtering. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter |
|
|
ipxSysOutCompressDiscards |
1.3.6.1.4.1.2.6.26.2.1.1.1.1.23 |
The number of outgoing IPX packets discarded due to
compression errors. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter |
|
|
ipxSysOutDiscards |
1.3.6.1.4.1.2.6.26.2.1.1.1.1.25 |
The number of outgoing IPX packets discarded due to
processing decision. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter |
|
|
ipxSysOutPackets |
1.3.6.1.4.1.2.6.26.2.1.1.1.1.26 |
The total number of IPX packets transmitted. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter |
|
|
ipxSysCircCount |
1.3.6.1.4.1.2.6.26.2.1.1.1.1.27 |
The number of circuits known to this instance of IPX. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter |
|
|
ipxSysDestCount |
1.3.6.1.4.1.2.6.26.2.1.1.1.1.28 |
The number of currently reachable destinations known to
this instance of IPX. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter |
|
|
ipxSysServCount |
1.3.6.1.4.1.2.6.26.2.1.1.1.1.29 |
The number of services known to this instance of IPX. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter |
|
|
ipxSysResourceFailures |
1.3.6.1.4.1.2.6.26.2.1.1.1.1.30 |
The number of times this instance of IPX has been
unable to obtain needed resources (memory, etc.). |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter |
|
|
ipxSysConfigSockets |
1.3.6.1.4.1.2.6.26.2.1.1.1.1.31 |
The configured maximum number of IPX sockets that may be
open at one time. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter |
|
|
ipxSysMaxOpenSockets |
1.3.6.1.4.1.2.6.26.2.1.1.1.1.32 |
The maximum number of IPX sockets actually open at one
time on this system. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter |
|
|
ipxSysOpenSocketFails |
1.3.6.1.4.1.2.6.26.2.1.1.1.1.33 |
The number of IPX socket open calls which failed. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter |
|
|
ipxCircTable |
1.3.6.1.4.1.2.6.26.2.1.2.1 |
The Circuit table. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
IPXCircEntry |
|
ipxCircEntry |
1.3.6.1.4.1.2.6.26.2.1.2.1.1 |
Each entry corresponds to one circuit known to the
system. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
IPXCircEntry |
|
|
ipxCircSysInstance |
1.3.6.1.4.1.2.6.26.2.1.2.1.1.1 |
The unique identifier of the instance of IPX
to which this entry corresponds. This value may be
written only when creating a new entry in the table. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
ipxCircIndex |
1.3.6.1.4.1.2.6.26.2.1.2.1.1.2 |
The identifier of this circuit, unique within the
instance of IPX. This value may be written
only when creating a new entry in the table. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
ipxCircExistState |
1.3.6.1.4.1.2.6.26.2.1.2.1.1.3 |
The validity of this circuit entry. A circuit with this
value set to off may be deleted from the table at the
IPX implementation's discretion. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
off(1), on(2) |
|
ipxCircOperState |
1.3.6.1.4.1.2.6.26.2.1.2.1.1.4 |
The operational state of the circuit. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
off(1), on(2) |
|
ipxCircIfIndex |
1.3.6.1.4.1.2.6.26.2.1.2.1.1.5 |
The value of ifIndex for the interface used by this
circuit. This value may be written only when creating
a new entry in the table. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
ipxCircName |
1.3.6.1.4.1.2.6.26.2.1.2.1.1.6 |
The readable name for the circuit. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(0..20) |
|
ipxCircInfo |
1.3.6.1.4.1.2.6.26.2.1.2.1.1.7 |
Additional readable information for the circuit. The
content of this field is implementation defined. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
ipxCircType |
1.3.6.1.4.1.2.6.26.2.1.2.1.1.8 |
The type of the circuit. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
other(1), broadcast(2), ptToPt(3), wanRIP(4), unnumberedRIP(5), dwnamic(6), wanWS(7) |
|
ipxCircLocalMaxPacketSize |
1.3.6.1.4.1.2.6.26.2.1.2.1.1.9 |
The maximum size (including header), in bytes, that the
system supports locally on this circuit. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
ipxCircCompressState |
1.3.6.1.4.1.2.6.26.2.1.2.1.1.10 |
The compression state on this circuit. This value may
be written only when creating a new entry in the table. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
off(1), on(2) |
|
ipxCircCompressSlots |
1.3.6.1.4.1.2.6.26.2.1.2.1.1.11 |
The number of compression slots available on this
circuit. This value may be written only when creating a
new entry in the table. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
ipxCircCompressedSent |
1.3.6.1.4.1.2.6.26.2.1.2.1.1.12 |
The number of compressed packets sent. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter |
|
|
ipxCircUncompressedSent |
1.3.6.1.4.1.2.6.26.2.1.2.1.1.13 |
The number of packets sent without being compressed
even though compression was turned on for this circuit. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter |
|
|
ipxCircNetNumber |
1.3.6.1.4.1.2.6.26.2.1.2.1.1.15 |
The IPX network number to which this circuit is bound. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
NetNumber |
|
|
ipxCircStateChanges |
1.3.6.1.4.1.2.6.26.2.1.2.1.1.16 |
The number of times the circuit has changed state. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter |
|
|
ipxCircInitFails |
1.3.6.1.4.1.2.6.26.2.1.2.1.1.17 |
The number of times that initialization of this
circuit has failed. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter |
|
|
ipxCircDelay |
1.3.6.1.4.1.2.6.26.2.1.2.1.1.18 |
The period of time, in milliseconds, that it takes to
transmit one byte of data, excluding protocol headers,
to a destination on the other end of the circuit, if
the circuit is free of other traffic. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
ipxCircThroughput |
1.3.6.1.4.1.2.6.26.2.1.2.1.1.19 |
The amounf of data, in bits per second, that may flow
through the circuit if there is no other traffic. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
ipxDestTable |
1.3.6.1.4.1.2.6.26.2.1.3.1 |
The Destination table contains information about all
known destinations. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
IPXDestEntry |
|
ipxDestEntry |
1.3.6.1.4.1.2.6.26.2.1.3.1.1 |
Each entry corresponds to one destination. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
IPXDestEntry |
|
|
ipxDestSysInstance |
1.3.6.1.4.1.2.6.26.2.1.3.1.1.1 |
The unique identifier of the instance of IPX
to which this row corresponds. This value may be written
only when creating a new entry with ipxDestProtocol
equal to static. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
ipxDestNetNum |
1.3.6.1.4.1.2.6.26.2.1.3.1.1.2 |
The IPX network number of the destination. This value
may be written only when creating a new entry with
ipxDestProtocol equal to static. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
NetNumber |
|
|
ipxDestProtocol |
1.3.6.1.4.1.2.6.26.2.1.3.1.1.3 |
The routing protocol from which knowledge of this
destination was obtained. This value may be written only
when creating a new entry with ipxDestProtocol equal
to static. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
other(1), local(2), rip(3), nlsp(4), static(5) |
|
ipxDestCost |
1.3.6.1.4.1.2.6.26.2.1.3.1.1.4 |
The cost to reach this destination. The meaning of the
cost value is dependent on the routing protocol (i. e.
Cost = delay in ticks for RIP, Cost = total path default
cost for NLSP, etc.). This value may be written only
when creating a new entry with ipxDestProtocol equal
to static. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
ipxDestHopCount |
1.3.6.1.4.1.2.6.26.2.1.3.1.1.5 |
The number of hops necessary to reach the destination.
This value may be written only when creating a new entry
with ipxDestProtocol equal to static. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
ipxDestNextHopCircIndex |
1.3.6.1.4.1.2.6.26.2.1.3.1.1.6 |
The unique identifier of the circuit used to reach the
next hop. This value may be written only when creating
a new entry with ipxDestProtocol equal to static. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
ipxDestNextHopNICAddress |
1.3.6.1.4.1.2.6.26.2.1.3.1.1.7 |
The NIC address of the next hop. This value may be
written only when creating a new entry with
ipxDestProtocol equal to static. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
ipxDestNextHopNetNum |
1.3.6.1.4.1.2.6.26.2.1.3.1.1.8 |
The IPX network number of the next hop. This value may
be written only when creating a new entry with
ipxDestProtocol equal to static. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
NetNumber |
|
|
ipxDestType |
1.3.6.1.4.1.2.6.26.2.1.3.1.1.9 |
Indicates whether the destination is a network or a
router. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
unknown(1), nlspLevel1Router(2), router(4), network(5) |
|
ipxServTable |
1.3.6.1.4.1.2.6.26.2.1.4.1 |
The table of services, indexed by name and type. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
IPXServEntry |
|
ipxServEntry |
1.3.6.1.4.1.2.6.26.2.1.4.1.1 |
Each entry corresponds to one service. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
IPXServEntry |
|
|
ipxServSysInstance |
1.3.6.1.4.1.2.6.26.2.1.4.1.1.1 |
The unique identifier of the instance of IPX
to which this entry corresponds. This value may be
written only when creating entries with the value of
ipxServProtocol equal to static. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
ipxServName |
1.3.6.1.4.1.2.6.26.2.1.4.1.1.2 |
The service name. This value may be written only when
creating entries with the value of ipxServProtocol
equal to static. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(0..48) |
|
ipxServTypeValue |
1.3.6.1.4.1.2.6.26.2.1.4.1.1.3 |
The service type's hexadecimal value. This value may be
written only when creating entries with the value of
ipxServProtocol equal to static. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(2) |
|
ipxServType |
1.3.6.1.4.1.2.6.26.2.1.4.1.1.4 |
The service type. This value may be written only when
creating entries with the value of ipxServProtocol
equal to static. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
unknown(1) |
|
ipxServProtocol |
1.3.6.1.4.1.2.6.26.2.1.4.1.1.5 |
The protocol from which knowledge of this service was
obtained. This value may be written only when the value
of ipxServProtocol is equal to static. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
other(1), local(2), nlsp(4), static(5), sap(6) |
|
ipxServNetNum |
1.3.6.1.4.1.2.6.26.2.1.4.1.1.6 |
The IPX network number portion of the IPX address of the
service. This value may be written only when creating
entries with the value of ipxServProtocol equal to
static. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
NetNumber |
|
|
ipxServNode |
1.3.6.1.4.1.2.6.26.2.1.4.1.1.7 |
The node portion of the IPX address of the service. This
value may be written only when creating entries with the
value of ipxServProtocol equal to static. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(6) |
|
ipxServSocket |
1.3.6.1.4.1.2.6.26.2.1.4.1.1.8 |
The socket portion of the IPX address of the service.
This value may be written only when creating entries with
the value of ipxServProtocol equal to static. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(2) |
|
ipxDestServTable |
1.3.6.1.4.1.2.6.26.2.1.4.2 |
The table of services, indexed by address, name,
and type. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
IPXDestServEntry |
|
ipxDestServEntry |
1.3.6.1.4.1.2.6.26.2.1.4.2.1 |
Each entry corresponds to one service. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
IPXDestServEntry |
|
|
ipxDestServSysInstance |
1.3.6.1.4.1.2.6.26.2.1.4.2.1.1 |
The unique identifier of the instance of IPX
to which this entry corresponds. This value may be
written only when creating entries with the value of
ipxDestServProtocol equal to static. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
ipxDestServNetNum |
1.3.6.1.4.1.2.6.26.2.1.4.2.1.2 |
The IPX network number portion of the IPX address of the
service. This value may be written only when creating
entries with the value of ipxDestServProtocol equal to
static. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
NetNumber |
|
|
ipxDestServNode |
1.3.6.1.4.1.2.6.26.2.1.4.2.1.3 |
The node portion of the IPX address of the service. This
value may be written only when creating entries with the
value of ipxDestServProtocol equal to static. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(6) |
|
ipxDestServSocket |
1.3.6.1.4.1.2.6.26.2.1.4.2.1.4 |
The socket portion of the IPX address of the service.
This value may be written only when creating entries with
the value of ipxDestServProtocol equal to static. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(2) |
|
ipxDestServName |
1.3.6.1.4.1.2.6.26.2.1.4.2.1.5 |
The service name. This value may be written only when
creating entries with the value of ipxDestServProtocol
equal to static. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(0..48) |
|
ipxDestServTypeValue |
1.3.6.1.4.1.2.6.26.2.1.4.2.1.6 |
The service type's hexadecimal value. This value may be
written only when creating entries with the value of
ipxDestServProtocol equal to static. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(2) |
|
ipxDestServType |
1.3.6.1.4.1.2.6.26.2.1.4.2.1.7 |
The service type. This value may be written only when
creating entries with the value of ipxDestServProtocol
equal to static. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
unknown(1) |
|
ipxDestServProtocol |
1.3.6.1.4.1.2.6.26.2.1.4.2.1.8 |
The protocol from which knowledge of this service was
obtained. This value may be written only when the value
of ipxDestServProtocol is equal to static. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
other(1), local(2), nlsp(4), static(5), sap(6) |
|
ripsap |
1.3.6.1.4.1.2.6.26.2.2 |
OBJECT IDENTIFIER |
|
|
|
ripsapSysTable |
1.3.6.1.4.1.2.6.26.2.2.1.1 |
The RIP/SAP system table. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
RIPSAPSysEntry |
|
ripsapSysEntry |
1.3.6.1.4.1.2.6.26.2.2.1.1.1 |
Each entry corresponds to one instance of RIP/SAP
running on the system. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
RIPSAPSysEntry |
|
|
ripsapSysInstance |
1.3.6.1.4.1.2.6.26.2.2.1.1.1.1 |
The unique identifier of the instance of RIP/SAP to
which this row corresponds. This value links the
instance of RIP/SAP to an instance of IPX running on the
system (i. e. the value of ripsapSysInstance should be the
same as a value of ipxSysInstance). This value may be
written only when creating a new entry in the table. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
ripsapSysRIPState |
1.3.6.1.4.1.2.6.26.2.2.1.1.1.2 |
Indicates the operational state of this instance of RIP. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
off(1), on(2) |
|
ripsapSysSAPState |
1.3.6.1.4.1.2.6.26.2.2.1.1.1.3 |
Indicates the operational state of this instance of SAP. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
off(1), on(2) |
|
ripsapSysRIPIncorrectPackets |
1.3.6.1.4.1.2.6.26.2.2.1.1.1.4 |
The number of times that an incorrectly formatted RIP
packet was received. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter |
|
|
ripsapSysSAPIncorrectPackets |
1.3.6.1.4.1.2.6.26.2.2.1.1.1.5 |
The number of times that an incorrectly formatted SAP
packet was received. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter |
|
|
ripsapCircEntry |
1.3.6.1.4.1.2.6.26.2.2.2.1.1 |
Each entry corresponds to one circuit known to the
system. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
RIPSAPCircEntry |
|
|
ripsapCircSysInstance |
1.3.6.1.4.1.2.6.26.2.2.2.1.1.1 |
The unique identifier of the instance of RIP/SAP and IPX
(via ipxSysInstance) to which this entry corresponds.
This value may be written only when creating a new entry in
the table. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
ripsapCircIndex |
1.3.6.1.4.1.2.6.26.2.2.2.1.1.2 |
The identifier of this circuit, unique within the
instance of RIP/SAP. This value corresponds to the circuit
identifier found in ipxCircIndex. This value may be
written only when creating a new entry in the table. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
ripsapCircRIPState |
1.3.6.1.4.1.2.6.26.2.2.2.1.1.3 |
Indicates whether RIP information may be sent/received
over this circuit. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
off(1), on(2) |
|
ripsapCircRIPPace |
1.3.6.1.4.1.2.6.26.2.2.2.1.1.4 |
The maximum pace, in packets per second, at which RIP
packets may be sent on this circuit. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
ripsapCircRIPUpdate |
1.3.6.1.4.1.2.6.26.2.2.2.1.1.5 |
The RIP periodic update interval, in seconds. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
ripsapCircRIPAgeMultiplier |
1.3.6.1.4.1.2.6.26.2.2.2.1.1.6 |
The holding multiplier for information received in RIP
periodic updates. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
ripsapCircRIPPacketSize |
1.3.6.1.4.1.2.6.26.2.2.2.1.1.7 |
The RIP packet size used on this circuit. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
ripsapCircRIPOutPackets |
1.3.6.1.4.1.2.6.26.2.2.2.1.1.8 |
The number of RIP packets sent on this circuit. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter |
|
|
ripsapCircRIPInPackets |
1.3.6.1.4.1.2.6.26.2.2.2.1.1.9 |
The number of RIP packets received on this circuit. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter |
|
|
ripsapCircSAPState |
1.3.6.1.4.1.2.6.26.2.2.2.1.1.10 |
Indicates whether SAP information may be sent/received
over this circuit. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
off(1), on(2) |
|
ripsapCircSAPPace |
1.3.6.1.4.1.2.6.26.2.2.2.1.1.11 |
The maximum pace, in packets per second, at which SAP
packets may be sent on this circuit. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
ripsapCircSAPUpdate |
1.3.6.1.4.1.2.6.26.2.2.2.1.1.12 |
The SAP periodic update interval, in seconds. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
ripsapCircSAPAgeMultiplier |
1.3.6.1.4.1.2.6.26.2.2.2.1.1.13 |
The holding multiplier for information received in SAP
periodic updates. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
ripsapCircSAPPacketSize |
1.3.6.1.4.1.2.6.26.2.2.2.1.1.14 |
The SAP packet size used on this circuit. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
ripsapCircSAPGetNearestServerReply |
1.3.6.1.4.1.2.6.26.2.2.2.1.1.15 |
Indicates whether to respond to SAP Get Nearest Server
requests received on this circuit. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
no(1), yes(2) |
|
ripsapCircSAPOutPackets |
1.3.6.1.4.1.2.6.26.2.2.2.1.1.16 |
The number of SAP packets sent on this circuit. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter |
|
|
ripsapCircSAPInPackets |
1.3.6.1.4.1.2.6.26.2.2.2.1.1.17 |
The number of SAP packets received on this circuit. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|