huawei |
1.3.6.1.4.1.2011 |
OBJECT IDENTIFIER |
|
|
|
products |
1.3.6.1.4.1.2011.2 |
OBJECT IDENTIFIER |
|
|
|
hwNmAgent |
1.3.6.1.4.1.2011.2.15.1 |
OBJECT IDENTIFIER |
|
|
|
hwNmFault |
1.3.6.1.4.1.2011.2.15.1.3 |
OBJECT IDENTIFIER |
|
|
|
thirdNMSFaultFilter |
1.3.6.1.4.1.2011.2.15.1.3.5 |
This is to add the filter condition by the upper NMS
the syntax is IP:Port:Alarm Level
Example : 127.0.0.1:161:0011
In this IP is 127.0.0.1
Port is 161
Alarm Level - Minor and warning should not be sent
as the bit is set for them |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(14..32) |
|
hwNmNorthboundNEName |
1.3.6.1.4.1.2011.2.15.1.7.1.1 |
The name of network element,string (255) |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(1..255) |
|
hwNmNorthboundNEType |
1.3.6.1.4.1.2011.2.15.1.7.1.2 |
Device type of element,string(64) |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(0..64) |
|
hwNmNorthboundObjectInstance |
1.3.6.1.4.1.2011.2.15.1.7.1.3 |
Instance of element,such as number of Rack, Frame, Slot, Subslot, Port and so on,string(255) |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(0..255) |
|
hwNmNorthboundEventType |
1.3.6.1.4.1.2011.2.15.1.7.1.4 |
Event type of Network management,string(64) |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(0..64) |
|
hwNmNorthboundEventTime |
1.3.6.1.4.1.2011.2.15.1.7.1.5 |
Alarm generate time,string(64),format: 2003/03/14 00:00:00 |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(0..64) |
|
hwNmNorthboundProbableCause |
1.3.6.1.4.1.2011.2.15.1.7.1.6 |
Reason of Probable caused alarm, string(64) |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(0..64) |
|
hwNmNorthboundSeverity |
1.3.6.1.4.1.2011.2.15.1.7.1.7 |
Level of Alarm, string(64) |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(0..64) |
|
hwNmNorthboundEventDetail |
1.3.6.1.4.1.2011.2.15.1.7.1.8 |
Alarm ID and detail information, format: ID+detail infomation, string(255) |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(0..255) |
|
hwNmNorthboundAdditionalInfo |
1.3.6.1.4.1.2011.2.15.1.7.1.9 |
Additional infomation of device, such as Country, City and so on, string(255) |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(0..255) |
|
hwNmNorthboundFaultFlag |
1.3.6.1.4.1.2011.2.15.1.7.1.10 |
The flag of the fault.Show whether the alarm is an event ,a fault alarm or a recovery alarm. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(0..64) |
|
hwNmNorthboundFaultFunction |
1.3.6.1.4.1.2011.2.15.1.7.1.11 |
The function type of the alarm.It can be one of these values:'Power','Environment','Signal','Relay','Hardware','Software','Run','Communication','Service','Processerror','UNKNOWN_FUC_TYPE' |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(0..64) |
|
hwNmNorthboundSerialNo |
1.3.6.1.4.1.2011.2.15.1.7.1.13 |
The serial number of alarm. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
hwNmNorthboundProbableRepair |
1.3.6.1.4.1.2011.2.15.1.7.1.14 |
The probable repair advice of the alarm. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(0..64) |
|
hwNmNorthboundResourceIDs |
1.3.6.1.4.1.2011.2.15.1.7.1.15 |
The ID of the resource. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(1..255) |
|
hwNmNorthboundsAdditionalVB1 |
1.3.6.1.4.1.2011.2.15.1.7.1.16 |
Addtional information of the alarm |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(1..255) |
|
hwNmNorthboundsAdditionalVB2 |
1.3.6.1.4.1.2011.2.15.1.7.1.17 |
Addtional information of the alarm |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(1..255) |
|
hwNmNorthboundsAdditionalVB3 |
1.3.6.1.4.1.2011.2.15.1.7.1.18 |
Addtional information of the alarm |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(1..255) |
|
hwNmNorthboundsAdditionalVB4 |
1.3.6.1.4.1.2011.2.15.1.7.1.19 |
Addtional information of the alarm |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(1..255) |
|
hwNmNorthboundsAdditionalVB5 |
1.3.6.1.4.1.2011.2.15.1.7.1.20 |
Addtional information of the alarm |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(1..255) |
|
hwNmNorthboundsAdditionalVB6 |
1.3.6.1.4.1.2011.2.15.1.7.1.21 |
Addtional information of the alarm |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(1..255) |
|
hwNmNorthboundsAdditionalVB7 |
1.3.6.1.4.1.2011.2.15.1.7.1.22 |
Addtional information of the alarm |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(1..255) |
|
hwNmNorthboundsAdditionalVB8 |
1.3.6.1.4.1.2011.2.15.1.7.1.23 |
Addtional information of the alarm |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(1..255) |
|
hwNmNorthboundEventName |
1.3.6.1.4.1.2011.2.15.1.7.1.24 |
The name of event,string (255) |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(1..255) |
|
hwNmNorthboundEventSynchronizationEndStatus |
1.3.6.1.4.1.2011.2.15.1.7.7.3.1 |
It shows the result of alarm synchronization.
1 means the alarm synchronization successfully ended.
2 means the alarm synchronization is stopped by the NMS's command.
3 means some error occured during the alarm synchronization. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
normalEnd(1), stopped(2), error(3) |
|
hwNmNorthboundEventSynchronizationCommandStart |
1.3.6.1.4.1.2011.2.15.1.7.7.4 |
This node is to be set to start the alarm synchronization.
It should be set as 'NMS's IP:port',and the agent will send alarm synchronization result to the IP and port specified.
If there is already an running alarm synchronization for that IP and port,it will return a commit fail error. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
hwNmNorthboundEventSynchronizationCommandStop |
1.3.6.1.4.1.2011.2.15.1.7.7.5 |
This node is to be set to stop the alarm synchronization.
It should be set as 'NMS's IP:port',and the agent will stop alarm synchronization for the IP and port specified.
If there is no such an running alarm synchronization for that IP and port,it will return a commit fail error. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|