HUAWEI-SNMP-EXT-MIB

File: HUAWEI-SNMP-EXT-MIB.mib (11497 bytes)

Imported modules

HUAWEI-MIB RFC1213-MIB SNMPv2-TC
SNMPv2-CONF P-BRIDGE-MIB SNMPv2-SMI
INET-ADDRESS-MIB

Imported symbols

hwDatacomm ifIndex ifDescr
DisplayString TruthValue OBJECT-GROUP
MODULE-COMPLIANCE NOTIFICATION-GROUP EnabledStatus
OBJECT-TYPE OBJECT-IDENTITY MODULE-IDENTITY
NOTIFICATION-TYPE Integer32 InetAddressType
InetAddress

Defined Values

hwSnmpExtMIB 1.3.6.1.4.1.2011.5.25.164
Some attribute of SNMP extended content.
MODULE-IDENTITY    

hwSnmpExtMIBObjects 1.3.6.1.4.1.2011.5.25.164.1
OBJECT IDENTIFIER    

hwSnmpExtErrorCodeEnable 1.3.6.1.4.1.2011.5.25.164.1.1
Enabled or disabled SNMP extended error status. The default value is disabled.
Status: current Access: read-write
OBJECT-TYPE    
  EnabledStatus  

hwSnmpRemoteIpAddressType 1.3.6.1.4.1.2011.5.25.164.1.2
The type of the remote netmanager IP address.
Status: current Access: not-accessible
OBJECT-TYPE    
  InetAddressType  

hwSnmpRemoteIpAddress 1.3.6.1.4.1.2011.5.25.164.1.3
The Ip address of the remote netmanager.
Status: current Access: not-accessible
OBJECT-TYPE    
  InetAddress Size(0|4|8|16|20)  

hwSnmpGlobalObjects 1.3.6.1.4.1.2011.5.25.164.1.4
OBJECT IDENTIFIER    

hwSnmpListenPort 1.3.6.1.4.1.2011.5.25.164.1.4.1
The listening UDP port of SNMP.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 161 | 1025..65535  

hwSnmpRaisingThreshold 1.3.6.1.4.1.2011.5.25.164.1.4.2
The raising threshold of the lock queue.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

hwSnmpFallingThreshold 1.3.6.1.4.1.2011.5.25.164.1.4.3
The falling threshold of the lock queue.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32  

hwSnmpFrameworkAdmin 1.3.6.1.4.1.2011.5.25.164.1.5
OBJECT IDENTIFIER    

hwSnmpAuthProtocols 1.3.6.1.4.1.2011.5.25.164.1.5.1
Registration point for authentication protocols used in Huawei extended SNMP MIB. Definitions of Object Identities needed for the use of AES by SNMP's User-based Security Model
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

hwUsmHMACSHA256AuthProtocol 1.3.6.1.4.1.2011.5.25.164.1.5.1.1
The HMAC SHA2 256 Digest Authentication Protocol.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

hwSnmpPrivProtocols 1.3.6.1.4.1.2011.5.25.164.1.5.2
Registration point for privacy protocols used in Huawei extended SNMP MIB. Definitions of Object Identities needed for the use of AES by SNMP's User-based Security Model
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

hwUsm3DESEDEPrivProtocol 1.3.6.1.4.1.2011.5.25.164.1.5.2.1
The 3DES-EDE Symmetric Encryption Protocol.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

hwUsmAESCfb192PrivProtocol 1.3.6.1.4.1.2011.5.25.164.1.5.2.2
The CFB128-AES-192 Privacy Protocol.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

hwUsmAESCfb256PrivProtocol 1.3.6.1.4.1.2011.5.25.164.1.5.2.3
The CFB128-AES-256 Privacy Protocol.
Status: current Access: accessible-for-notify
OBJECT-IDENTITY    

hwSnmpNotification 1.3.6.1.4.1.2011.5.25.164.1.6
OBJECT IDENTIFIER    

hwNmsPingTrap 1.3.6.1.4.1.2011.5.25.164.1.6.1
SNMP Test trap.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

hwNmsHeartBeatTrap 1.3.6.1.4.1.2011.5.25.164.1.6.2
SNMP Test trap.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

hwSnmpExtConformance 1.3.6.1.4.1.2011.5.25.164.2
OBJECT IDENTIFIER    

hwSnmpExtGroups 1.3.6.1.4.1.2011.5.25.164.2.1
OBJECT IDENTIFIER    

hwSnmpExtRuleGroup 1.3.6.1.4.1.2011.5.25.164.2.1.1
Collection of objects needed for SNMP extended configuration.
Status: current Access: accessible-for-notify
OBJECT-GROUP    

hwSnmpExtTrapGroup 1.3.6.1.4.1.2011.5.25.164.2.1.2
SNMP extend trap nodes.
Status: current Access: accessible-for-notify
NOTIFICATION-GROUP    

hwSnmpExtCompliances 1.3.6.1.4.1.2011.5.25.164.2.2
OBJECT IDENTIFIER    

hwSnmpExtCompliance 1.3.6.1.4.1.2011.5.25.164.2.2.1
The compliance statement for implementing the Huawei extended SNMP MIB.
Status: current Access: accessible-for-notify
MODULE-COMPLIANCE    

hwSnmpAlarmGroups 1.3.6.1.4.1.2011.5.25.164.1.6.3
OBJECT IDENTIFIER    

hwSnmpAlarmGroup 1.3.6.1.4.1.2011.5.25.164.1.6.3.1
Alarm trap nodes.
Status: current Access: accessible-for-notify
NOTIFICATION-GROUP    

hwSnmpExtNotifications 1.3.6.1.4.1.2011.5.25.164.3
OBJECT IDENTIFIER    

hwSNMPLockThreshold 1.3.6.1.4.1.2011.5.25.164.3.1
The trap will be triggered when the number of unauthorized users reaches the upper threshold of the lock queue.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

hwSNMPLockThresholdResume 1.3.6.1.4.1.2011.5.25.164.3.2
The trap will be triggered when the number of unauthorized users falls back to the lower threshold of the lock queue.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE