HP-ICF-TRANSCEIVER-MIB

File: HP-ICF-TRANSCEIVER-MIB.mib (58361 bytes)

Imported modules

SNMPv2-SMI SNMP-FRAMEWORK-MIB SNMPv2-CONF
SNMPv2-TC HP-ICF-OID IF-MIB

Imported symbols

OBJECT-TYPE MODULE-IDENTITY Integer32
Unsigned32 TimeTicks SnmpAdminString
MODULE-COMPLIANCE OBJECT-GROUP TruthValue
hpSwitch ifIndex

Defined Types

HpicfXcvrInfoEntry  
SEQUENCE    
  hpicfXcvrPortIndex Integer32
  hpicfXcvrPortDesc SnmpAdminString
  hpicfXcvrModel SnmpAdminString
  hpicfXcvrSerial SnmpAdminString
  hpicfXcvrType SnmpAdminString
  hpicfXcvrConnectorType SnmpAdminString
  hpicfXcvrWavelength SnmpAdminString
  hpicfXcvrTxDist SnmpAdminString
  hpicfXcvrDiagnostics INTEGER
  hpicfXcvrDiagnosticsUpdate TruthValue
  hpicfXcvrTemp Integer32
  hpicfXcvrVoltage Unsigned32
  hpicfXcvrBias Unsigned32
  hpicfXcvrTxPower Integer32
  hpicfXcvrRxPower Integer32
  hpicfXcvrAlarms BITS
  hpicfXcvrErrors BITS
  hpicfXcvrTempHiAlarm Integer32
  hpicfXcvrTempLoAlarm Integer32
  hpicfXcvrTempHiWarn Integer32
  hpicfXcvrTempLoWarn Integer32
  hpicfXcvrVccHiAlarm Unsigned32
  hpicfXcvrVccLoAlarm Unsigned32
  hpicfXcvrVccHiWarn Unsigned32
  hpicfXcvrVccLoWarn Unsigned32
  hpicfXcvrBiasHiAlarm Unsigned32
  hpicfXcvrBiasLoAlarm Unsigned32
  hpicfXcvrBiasHiWarn Unsigned32
  hpicfXcvrBiasLoWarn Unsigned32
  hpicfXcvrPwrOutHiAlarm Unsigned32
  hpicfXcvrPwrOutLoAlarm Unsigned32
  hpicfXcvrPwrOutHiWarn Unsigned32
  hpicfXcvrPwrOutLoWarn Unsigned32
  hpicfXcvrRcvPwrHiAlarm Unsigned32
  hpicfXcvrRcvPwrLoAlarm Unsigned32
  hpicfXcvrRcvPwrHiWarn Unsigned32
  hpicfXcvrRcvPwrLoWarn Unsigned32
  hpicfXcvrDiagnosticsTimeStamp SnmpAdminString
  hpicfXcvrPhyLinkStatus INTEGER
  hpicfXcvrPhySpeed Unsigned32
  hpicfXcvrPhyDuplex INTEGER
  hpicfXcvrMdiPairACableStatus INTEGER
  hpicfXcvrMdiPairACableLength Unsigned32
  hpicfXcvrMdiPairADistanceToFault Unsigned32
  hpicfXcvrMdiPairAPolaritySwap INTEGER
  hpicfXcvrMdiPairASkew Unsigned32
  hpicfXcvrMdiPairBCableStatus INTEGER
  hpicfXcvrMdiPairBCableLength Unsigned32
  hpicfXcvrMdiPairBDistanceToFault Unsigned32
  hpicfXcvrMdiPairBPolaritySwap INTEGER
  hpicfXcvrMdiPairBSkew Unsigned32
  hpicfXcvrMdiPairCCableStatus INTEGER
  hpicfXcvrMdiPairCCableLength Unsigned32
  hpicfXcvrMdiPairCDistanceToFault Unsigned32
  hpicfXcvrMdiPairCPolaritySwap INTEGER
  hpicfXcvrMdiPairCSkew Unsigned32
  hpicfXcvrMdiPairDCableStatus INTEGER
  hpicfXcvrMdiPairDCableLength Unsigned32
  hpicfXcvrMdiPairDDistanceToFault Unsigned32
  hpicfXcvrMdiPairDPolaritySwap INTEGER
  hpicfXcvrMdiPairDSkew Unsigned32
  hpicfXcvrMdiPairABSwap INTEGER
  hpicfXcvrMdiPairCDSwap INTEGER
  hpicfXcvrDiagnosticsTimeTicks TimeTicks

Defined Values

hpicfTransceiverMIB 1.3.6.1.4.1.11.2.14.11.5.1.82
This MIB module describes HP transceiver information.
MODULE-IDENTITY    

hpicfXcvrObjects 1.3.6.1.4.1.11.2.14.11.5.1.82.1
OBJECT IDENTIFIER    

hpicfXcvrInfo 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1
OBJECT IDENTIFIER    

hpicfXcvrInfoTable 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1
A table of objects that display transceiver characteristics.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    HpicfXcvrInfoEntry

hpicfXcvrInfoEntry 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1
A set of objects that displays information of a transceiver.
Status: current Access: not-accessible
OBJECT-TYPE    
  HpicfXcvrInfoEntry  

hpicfXcvrPortIndex 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.1
The interface number for this entry.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..2147483647  

hpicfXcvrPortDesc 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.2
A textual description of the interface.
Status: current Access: read-only
OBJECT-TYPE    
  SnmpAdminString Size(1..8)  

hpicfXcvrModel 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.3
A textual description of the transceiver model number.
Status: current Access: read-only
OBJECT-TYPE    
  SnmpAdminString Size(1..32)  

hpicfXcvrSerial 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.4
A textual description of the transceiver serial number.
Status: current Access: read-only
OBJECT-TYPE    
  SnmpAdminString Size(1..32)  

hpicfXcvrType 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.5
A textual description of the transceiver type.
Status: current Access: read-only
OBJECT-TYPE    
  SnmpAdminString Size(1..32)  

hpicfXcvrConnectorType 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.6
A textual description of the transceiver connector type.
Status: current Access: read-only
OBJECT-TYPE    
  SnmpAdminString Size(1..64)  

hpicfXcvrWavelength 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.7
A textual description of the central optical wavelength. n/a will be reported for copper transceivers.
Status: current Access: read-only
OBJECT-TYPE    
  SnmpAdminString Size(1..96)  

hpicfXcvrTxDist 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.8
A textual description of the link length supported by the transceiver.
Status: current Access: read-only
OBJECT-TYPE    
  SnmpAdminString Size(1..64)  

hpicfXcvrDiagnostics 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.9
This object indicates transceiver diagnostic support. May be one of Virtual Cable Test (VCT), Diagnostic Optical Monitoring (DOM), other or none.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(0), dom(1), vct(2), other(3)  

hpicfXcvrDiagnosticsUpdate 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.10
This object will cause specific actions depending on the diagnostic support of the transceiver. Transceiver Diagnostic support: None : No action taken. DOM : Will update diagnostic information for the transceiver. VCT : Will update diagnostic information for the transceiver. Other : Vendor specific. The value of the object will be reset after the completion of the update. Please note: VCT and other (cable-diagnostics) may cause a loss of link and take a few second to run for each interface.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

hpicfXcvrTemp 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.11
This is transceiver internal temperature in thousandths of degrees Celsius. As an example: 49120 is 49.120 degrees Celsius. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hpicfXcvrVoltage 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.12
This is transceiver supply voltage in hundreds of microvolts. As an example: 32928 is 3.2928 volts. Will be zero if the transceiver does not report this object. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..65535  

hpicfXcvrBias 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.13
This is Tx bias current in microamps. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..65535  

hpicfXcvrTxPower 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.14
This is transmit output power in thousandths of dBm. As an example: -5840 is -5.840dBm. -in dBm (0 microwatts) will be reported as -99999999. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hpicfXcvrRxPower 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.15
This is received optical power in thousandths of dBm. As an example: -5840 is -5.840dBm. -in dBm (0 microwatts) will be reported as -99999999. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hpicfXcvrAlarms 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.16
Bitmask indicating transceiver alarms, Rx power low warning(0) Rx power high warning(1) Tx power low warning(2) Tx power high warning(3) Tx bias low warning(4) Tx bias high warning(5) Vcc low warning(6) Vcc high warning(7) Temp low warning(8) Temp high warning(9) Rx power low alarm(10) Rx power high alarm(11) Tx power low alarm(12) Tx power high alarm(13) Tx bias low alarm(14) Tx bias high alarm(15) Vcc low alarm(16) Vcc high alarm(17) Temp low alarm(18) Temp high alarm(19) Unused(20-31) The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.
Status: current Access: read-only
OBJECT-TYPE    
  BITS rxPowerLowWarning(0), rxPowerHighWarning(1), txPowerLowWarning(2), txPowerHighWarning(3), txBiasLowWarning(4), txBiasHighWarning(5), vccLowWarning(6), vccHighWarning(7), tempLowWarning(8), tempHighWarning(9), rxPowerLowAlarm(10), rxPowerHighAlarm(11), txPowerLowAlarm(12), txPowerHighAlarm(13), txBiasLowAlarm(14), txBiasHighAlarm(15), vccLowAlarm(16), vccHighAlarm(17), tempLowAlarm(18), tempHighAlarm(19)  

hpicfXcvrErrors 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.17
Bitmask indicating transceiver errors. Transceiver information I/O error(0) Transceiver information checksum error(1) Transceiver type and port configuration mismatch(2) Transceiver type not supported by port hardware(3) WIS local fault(4) Receive optical power fault(5) PMA/PMD receiver local fault(6) PCS receive local fault(7) PHY XS receive local fault(8) Laser bias current fault(9) Laser temperature fault(10) Laser output power fault(11) TX fault(12) PMA/PMD transmitter local fault(13) PCS transmit local fault(14) PHY XS Transmit Local Fault(15) RX loss of signal(16) Unused(17-31) The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.
Status: current Access: read-only
OBJECT-TYPE    
  BITS xcvrIOError(0), xcvrChecksum(1), xcvrTypeAndPortConfigMismatch(2), xcvrTypeNotSupported(3), wisLocalFault(4), rcvOpticalPowerFault(5), pmapmdReceiverLocalFault(6), pcsReceiveLocalFault(7), phyXSReceiveLocalFault(8), laserBiasCurrentFault(9), laserTemperatureFault(10), laserOutputPowerFault(11), txFault(12), pmapmdTransmitterLocalFault(13), pcsTransmitLocalFault(14), phyXSTransmitLocalFault(15), rxLossOfSignal(16)  

hpicfXcvrTempHiAlarm 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.18
Transceiver temperature high alarm threshold limit in thousandths of degrees Celsius. As an example: 49120 is 49.120 degrees Celsius. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hpicfXcvrTempLoAlarm 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.19
Transceiver temperature low alarm threshold limit in thousandths of degrees Celsius. As an example: 49120 is 49.120 degrees Celsius. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hpicfXcvrTempHiWarn 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.20
Transceiver temperature high warning threshold limit in thousandths of degrees Celsius. As an example: 49120 is 49.120 degrees Celsius. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hpicfXcvrTempLoWarn 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.21
Transceiver temperature low warning threshold limit in thousandths of degrees Celsius. As an example: 49120 is 49.120 degrees Celsius. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hpicfXcvrVccHiAlarm 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.22
Transceiver VCC high alarm threshold limit in hundreds of microvolts. As an example: 32928 is 3.2928 volts. Returns zero if not supported on the transceiver. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..65535  

hpicfXcvrVccLoAlarm 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.23
Transceiver VCC low alarm threshold limit in hundreds of microvolts. As an example: 32928 is 3.2928 volts. Returns zero if not supported on the transceiver. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..65535  

hpicfXcvrVccHiWarn 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.24
Transceiver VCC high warning threshold limit in hundreds of microvolts. As an example: 32928 is 3.2928 volts. Returns zero if not supported on the transceiver. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..65535  

hpicfXcvrVccLoWarn 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.25
Transceiver VCC low warning threshold limit in hundreds of microvolts. As an example: 32928 is 3.2928 volts. Returns zero if not supported on the transceiver. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..65535  

hpicfXcvrBiasHiAlarm 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.26
Transceiver bias high alarm threshold limit in microamps. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..65535  

hpicfXcvrBiasLoAlarm 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.27
Transceiver bias low alarm threshold limit in microamps. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..65535  

hpicfXcvrBiasHiWarn 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.28
Transceiver bias high warning threshold limit in microamps. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..65535  

hpicfXcvrBiasLoWarn 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.29
Transceiver bias low warning threshold limit in microamps. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..65535  

hpicfXcvrPwrOutHiAlarm 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.30
Transceiver transmit power high alarm threshold limit in tenths of microwatts. As an example: 10000 is 1 milliwatt. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..65535  

hpicfXcvrPwrOutLoAlarm 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.31
Transceiver transmit power low alarm threshold limit in tenths of microwatts. As an example: 10000 is 1 milliwatt. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..65535  

hpicfXcvrPwrOutHiWarn 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.32
Transceiver transmit power high warning threshold limit in tenths of microwatts As an example: 10000 is 1 milliwatt. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..65535  

hpicfXcvrPwrOutLoWarn 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.33
Transceiver transmit power low warning threshold limit in tenths of microwatts. As an example: 10000 is 1 milliwatt. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..65535  

hpicfXcvrRcvPwrHiAlarm 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.34
Transceiver receive power high alarm threshold limit in tenths of microwatts. As an example: 10000 is 1 milliwatt. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..65535  

hpicfXcvrRcvPwrLoAlarm 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.35
Transceiver receive power low alarm threshold limit in tenths of microwatts. As an example: 10000 is 1 milliwatt. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..65535  

hpicfXcvrRcvPwrHiWarn 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.36
Transceiver receive power high warning threshold limit in tenths of microwatts. As an example: 10000 is 1 milliwatt. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..65535  

hpicfXcvrRcvPwrLoWarn 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.37
Transceiver receive power low warning threshold limit in tenths of microwatts. As an example: 10000 is 1 milliwatt. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is DOM.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..65535  

hpicfXcvrDiagnosticsTimeStamp 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.38
********* THIS OBJECT IS DEPRECATED ********* A textual description of the diagnostics information updated for the last time in the transceiver. This object has been deprecated. Its functionality has been replaced by hpicfXcvrDiagnosticsTimeticks.
Status: deprecated Access: read-only
OBJECT-TYPE    
  SnmpAdminString Size(1..64)  

hpicfXcvrPhyLinkStatus 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.39
This object indicates the link status as reported by the physical entity. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER down(0), up(1)  

hpicfXcvrPhySpeed 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.40
This object indicates the speed in Mbps as reported by the physical entity. Will be zero if speed and duplex are unresolved. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967295  

hpicfXcvrPhyDuplex 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.41
This object indicates the duplex as reported by the physical entity. Will be unspecified if speed and duplex are unresolved. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER half(0), full(1), unspecified(2)  

hpicfXcvrMdiPairACableStatus 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.42
This object indicates the diagnostics test status on the cable pair. Normal = No cable fault detected. Open = Lack of continuity between ends. Short = Short detected. Impedance mismatch = - Cable pair is not connected properly or - Cable pair is damaged or - Connector is faulty. Failed = TDR test failed on cable pair. Unspecified : This object is unavailable or not reported. As reported through cable diagnostics. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER normal(0), short(1), open(2), failed(3), impedanceMismatch(4), unspecified(5)  

hpicfXcvrMdiPairACableLength 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.43
This object indicates the cable pair length in meters as reported by cable diagnostics. A gigabit link must be present for this object to be non zero. Will be zero if not available or the transceiver does not report this object. Accuracy is +/- 10 meters. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967295  

hpicfXcvrMdiPairADistanceToFault 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.44
This object indicates the distance in meters to a fault in the cable pair as reported through cable diagnostics. Will be zero if no fault or the transceiver does not report this object. Accuracy is +/- 2 meters. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967295  

hpicfXcvrMdiPairAPolaritySwap 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.45
This object indicates if the cable pair connected to the phy is inverted as reported through cable diagnostics. Will be unspecified if the this object is unavailable or not reported. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER normal(0), reversed(1), unspecified(2)  

hpicfXcvrMdiPairASkew 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.46
This object indicates the delay skew in nanoseconds of this cable pair and the fastest cable pair as reported through cable diagnostics. Will be zero if the lowest of the pairs or if the transceiver does not report this object. Accuracy is +/- 8 ns. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967295  

hpicfXcvrMdiPairBCableStatus 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.47
This object indicates the cable diagnostics test status on the cable pair. Normal = No cable fault detected. Open = Lack of continuity between ends. Short = Short detected. Impedance mismatch = - Cable pair is not connected properly or - Cable pair is damaged or - Connector is faulty. Failed = TDR test failed on cable pair. Unspecified : This object is unavailable or not reported. As reported through cable diagnostics. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER normal(0), short(1), open(2), failed(3), impedanceMismatch(4), unspecified(5)  

hpicfXcvrMdiPairBCableLength 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.48
This object indicates the cable pair length in meters as reported by cable diagnostics. A gigabit link must be present for this object to be non zero. Will be zero if not available or the transceiver does not report this object. Accuracy is +/- 10 meters. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967295  

hpicfXcvrMdiPairBDistanceToFault 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.49
This object indicates the distance in meters to a fault in the cable pair as reported through cable diagnostics. Will be zero if no fault or the transceiver does not report this object. Accuracy is +/- 2 meters. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967295  

hpicfXcvrMdiPairBPolaritySwap 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.50
This object indicates if the cable pair connected to the phy were inverted as reported through cable diagnostics. Will be unspecified if the this object is unavailable or not reported. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER normal(0), reversed(1), unspecified(2)  

hpicfXcvrMdiPairBSkew 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.51
This object indicates the delay skew in nanoseconds of this cable pair and the fastest cable pair as reported through cable diagnostics. Will be zero if the lowest of the pairs or if the transceiver does not report this object. Accuracy is +/- 8 ns. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967295  

hpicfXcvrMdiPairCCableStatus 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.52
This object indicates the cable diagnostics test status on the cable pair. Normal = No cable fault detected. Open = Lack of continuity between ends. Short = Short detected. Impedance Mismatch = - Cable pair is not connected properly or - Cable pair is damaged or - Connector is faulty. Failed = TDR test failed on cable pair. Unspecified : This object is unavailable or not reported. As reported through cable diagnostics. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER normal(0), short(1), open(2), failed(3), impedanceMismatch(4), unspecified(5)  

hpicfXcvrMdiPairCCableLength 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.53
This object indicates the cable length in meters of the cable pair as reported through cable diagnostics. A gigabit link must be present for this object to be non zero. Will be zero if not available or the transceiver does not report this object. Accuracy is +/- 10 meters. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967295  

hpicfXcvrMdiPairCDistanceToFault 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.54
This object indicates the distance in meters to a fault in the cable pair as reported through cable diagnostics. Will be zero if there is no fault or the transceiver does not report this object. Accuracy is +/- 2 meters. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967295  

hpicfXcvrMdiPairCPolaritySwap 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.55
This object indicates if the cable pair connected to the phy were inverted as reported through cable diagnostics. Will be unspecified if the this object is unavailable or not reported. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER normal(0), reversed(1), unspecified(2)  

hpicfXcvrMdiPairCSkew 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.56
This object indicates the delay skew in nanoseconds of this cable pair and the fastest cable pair as reported through cable diagnostics. Will be zero if the lowest of the pairs or if the transceiver does not report this object. Accuracy is +/- 8 ns. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967295  

hpicfXcvrMdiPairDCableStatus 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.57
This object indicates the cable diagnostics test status on the cable pair. Normal = No cable fault detected. Open = Lack of continuity between ends. Short = Short detected. Impedance Mismatch = - Cable pair is not connected properly or - Cable pair is damaged or - Connector is faulty. Failed = TDR test failed on cable pair. Unspecified : This object is unavailable or not reported. As reported through cable diagnostics. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER normal(0), short(1), open(2), failed(3), impedanceMismatch(4), unspecified(5)  

hpicfXcvrMdiPairDCableLength 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.58
This object indicates the cable length in meters of the cable pair as reported through cable diagnostics. A gigabit link must be present for this object to be non zero. Will be zero if not available or the transceiver does not report this object. Accuracy is +/- 10 meters. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967295  

hpicfXcvrMdiPairDDistanceToFault 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.59
This object indicates the distance in meters to a fault in the cable pair as reported through cable diagnostics. Will be zero if no fault or the transceiver does not report this object. Accuracy is +/- 2 meters. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967295  

hpicfXcvrMdiPairDPolaritySwap 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.60
This object indicates if the cable pair connected to the phy were inverted as reported through cable diagnostics. Will be unspecified if the this object is unavailable or not reported. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER normal(0), reversed(1), unspecified(2)  

hpicfXcvrMdiPairDSkew 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.61
This object indicates the delay skew in nanoseconds of this cable pair and the fastest cable pair as reported through cable diagnostics. Will be zero if the lowest of the pairs or if the transceiver does not report this object. Accuracy is +/- 8 ns. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967295  

hpicfXcvrMdiPairABSwap 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.62
This object indicates the if the channels are swapped for channels A and B as reported through cable diagnostics. MDI : Channel A received on MDI[1], Channel B on MDI[0] MDIX : Channel A received on MDI[0], Channel B on MDI[1] Unspecified : This object is unavailable or not reported. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER mdi(0), mdix(1), unspecified(2)  

hpicfXcvrMdiPairCDSwap 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.63
This object indicates if the channels are swapped for channels C and D as reported through cable diagnostics. MDI : Channel C received on MDI[3], Channel D on MDI[2] MDIX : Channel C received on MDI[2], Channel D on MDI[3]. Unspecified : This object is unavailable or not reported. The value of this object is valid when the value of the hpicfXcvrDiagnostics object is VCT or other.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER mdi(0), mdix(1), unspecified(2)  

hpicfXcvrDiagnosticsTimeTicks 1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.64
The value of sysUpTime of when this diagnostic information was last updated. If this diagnostic information was never updated, then this object will contain a zero value.
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

hpicfXcvrConformance 1.3.6.1.4.1.11.2.14.11.5.1.82.2
OBJECT IDENTIFIER    

hpicfXcvrGroups 1.3.6.1.4.1.11.2.14.11.5.1.82.2.1
OBJECT IDENTIFIER    

hpicfXcvrInfoGroup 1.3.6.1.4.1.11.2.14.11.5.1.82.2.1.1
********* THIS GROUP IS DEPRECATED ********* A collection of objects representing transceiver information. This object has been deprecated and replaced with hpicfXcvrInfoGroup1.
Status: deprecated Access: read-only
OBJECT-GROUP    

hpicfXcvrInfoGroup1 1.3.6.1.4.1.11.2.14.11.5.1.82.2.1.2
A collection of objects representing transceiver information.
Status: current Access: read-only
OBJECT-GROUP    

hpicfXcvrCompliances 1.3.6.1.4.1.11.2.14.11.5.1.82.2.2
OBJECT IDENTIFIER    

hpicfXcvrCompliance 1.3.6.1.4.1.11.2.14.11.5.1.82.2.2.1
********* THIS COMPLIANCE IS DEPRECATED ********* Describes the requirements for conformance to the transceiver MIB. This compliance section has been deprecated and replaced with hpicfXcvrCompliance1.
Status: deprecated Access: read-only
MODULE-COMPLIANCE    

hpicfXcvrCompliance1 1.3.6.1.4.1.11.2.14.11.5.1.82.2.2.2
Describes the requirements for conformance to the transceiver MIB.
Status: current Access: read-only
MODULE-COMPLIANCE