HH3C-POWER-ETH-EXT-MIB

File: HH3C-POWER-ETH-EXT-MIB.mib (63899 bytes)

Imported modules

HH3C-OID-MIB POWER-ETHERNET-MIB SNMPv2-CONF
SNMPv2-SMI SNMPv2-TC

Imported symbols

hh3cCommon pethPsePortGroupIndex pethPsePortIndex
pethMainPseGroupIndex pethPsePortDetectionStatus OBJECT-GROUP
MODULE-COMPLIANCE Integer32 OBJECT-TYPE
MODULE-IDENTITY NOTIFICATION-TYPE DisplayString
RowStatus

Defined Types

Hh3cPsePortEntry  
SEQUENCE    
  hh3cPsePortFaultDescription DisplayString
  hh3cPsePortPeakPower Integer32
  hh3cPsePortAveragePower Integer32
  hh3cPsePortCurrentPower Integer32
  hh3cPsePortPowerLimit Integer32
  hh3cPsePortProfileIndex Integer32

Hh3cMainPseEntry  
SEQUENCE    
  hh3cMainGuaranteedPowerRemaining Integer32
  hh3cMainPsePeakPower Integer32
  hh3cMainPseAveragePower Integer32
  hh3cMainPsePowerLimit Integer32
  hh3cMainPsePriorityMode INTEGER
  hh3cMainPseLegacy INTEGER
  hh3cMainPsePowerPriority INTEGER

Hh3cPseProfilesEntry  
SEQUENCE    
  hh3cPseProfileIndex Integer32
  hh3cPseProfileName DisplayString
  hh3cPseProfilePowerMode INTEGER
  hh3cPseProfilePowerLimit Integer32
  hh3cPseProfilePriority INTEGER
  hh3cPseProfilePairs INTEGER
  hh3cPseProfileApplyNum Integer32
  hh3cPseProfileRowStatus RowStatus

ACAlarmState  
INTEGER normal(1), underLimit(2), aboveLimit(3), lackPhrase(4), fuseBroken(5), switchOff(6), otherError(7)    

DCAlarmState  
INTEGER normal(1), underLimit(2), aboveLimit(3), fuseBroken(4), switchOff(5), otherError(6)    

SwitchState  
INTEGER on(1), off(2), highVoltInput(3), lowVoltInput(4)    

ModuleAlarmState  
INTEGER normal(1), alarm(2)    

Hh3cPOEModuleInfoEntry  
SEQUENCE    
  hh3cPOEModuleIndex Integer32
  hh3cPOEModuleID Integer32
  hh3cPOEModuleInfoPower Integer32
  hh3cPOEModuleHardVerInfo OCTET STRING

Hh3cPOEDCOutStateEntry  
SEQUENCE    
  hh3cPOEDCOutStateIndex Integer32
  hh3cPOEDCOutDCVolAlarm DCAlarmState

Hh3cPOEDCOutInfoEntry  
SEQUENCE    
  hh3cPOEDCOutInfoIndex Integer32
  hh3cPOEDCOutVol OCTET STRING
  hh3cPOEDCOutInfoLoadCur OCTET STRING

Hh3cPOEACSwitchStateEntry  
SEQUENCE    
  hh3cPOEACSwitchStateIndex Integer32
  hh3cPOEACSwitchState SwitchState

Hh3cPOESwitchStateVolExEntry  
SEQUENCE    
  hh3cPOESwitchStateVolExIndex Integer32
  hh3cPOESwitchStateInVolAB ACAlarmState
  hh3cPOESwitchStateInVolBC ACAlarmState
  hh3cPOESwitchStateInVolCA ACAlarmState

Hh3cPOEAlarmStateInfoEntry  
SEQUENCE    
  hh3cPOEAlarmModuleInfoIndex Integer32
  hh3cPOEModuleDisconnect ModuleAlarmState
  hh3cPOEModuleInputError ModuleAlarmState
  hh3cPOEModuleOutputError ModuleAlarmState
  hh3cPOEModuleOverVoltage ModuleAlarmState
  hh3cPOEModuleOverTemp ModuleAlarmState
  hh3cPOEModuleFanError ModuleAlarmState
  hh3cPOEModuleShutdown ModuleAlarmState
  hh3cPOEModuleCurRestricted ModuleAlarmState

Defined Values

hh3cPowerEthernetExt 1.3.6.1.4.1.25506.2.14
Description.
MODULE-IDENTITY    

hh3cPsePortTable 1.3.6.1.4.1.25506.2.14.1
The indexing scheme is taken form that used by the IETF Power MIB. The same indexing scheme is used to give continuity in behaviour between that standard and this extensions definitioin.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Hh3cPsePortEntry

hh3cPsePortEntry 1.3.6.1.4.1.25506.2.14.1.1
The pethPsePortGroupIndex is imported from the IETF Power MIB and uniquely identifies the group containing the port to which power ethernet PSE is connected. Group means (box in the stack, module in a rack). The pethPsePortPowerIndex is imported from the IETF Power MIB and uniquely identifies the power ethernet PSE port within group pethPseGroupIndex to which the power Ethernet PSE entry is connected. This value will match the local port number on a switch.
Status: current Access: not-accessible
OBJECT-TYPE    
  Hh3cPsePortEntry  

hh3cPsePortFaultDescription 1.3.6.1.4.1.25506.2.14.1.1.2
The object supports the fault category of the IETF Power MIB [1] pethPsePortDetectionStatus object. A textual description containing more information about the nature of this fault is provided by this object. Typically this will detail the precise PoE hardware state which is causing the pethPsePortDetectionStatus object to be in the 'fault' state. It is a DisplayString of up to 255 characters.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

hh3cPsePortPeakPower 1.3.6.1.4.1.25506.2.14.1.1.3
The object specifies the peak power which has been consumed by the port. It is defined as the highest measured value of power in milliWatts that has been consumed by the port. Its value is only reset when link is lost, the port is PoE disabled or when it is manually reset by the user asspecified below. It is a read/write integer value with units of milliWatts. Writing a value of zero to this object resets its value to zero. Writing any other value to this object has no effect on its value and an error is returned.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

hh3cPsePortAveragePower 1.3.6.1.4.1.25506.2.14.1.1.4
The object specifies the average power which has been consumed by the port. This object is a read/write integer value with units of milliWatts. Writing a value of zero to this object resets its value to zero. Writing any other value to this object has no effect on its value and an error is returned.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

hh3cPsePortCurrentPower 1.3.6.1.4.1.25506.2.14.1.1.5
The object specifies the power currently being consumed by the port. It is a read only integer value with units of milliWatts.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hh3cPsePortPowerLimit 1.3.6.1.4.1.25506.2.14.1.1.6
The object specifies the power limit set for this port. The PSE will not supply more than this level of power to the specified port. It is a read/write integer value with units of milliWatts.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

hh3cPsePortProfileIndex 1.3.6.1.4.1.25506.2.14.1.1.7
Indicates the power profile which is currently associated with this port. This object references the corresponding hh3cPseProfileIndex object in the power profiles table. A value of zero is a special case and indicates that no power profile is currently associated with this port. When hh3cPseProfileIndex is set to an index of existent profile, pethPsePortPowerPairs, pethPsePortPowerPriority, pethPsePortAdminEnable and hh3cPsePortPowerLimit will be set to the same as corresponding value. PethPsePortPowerPairs, pethPsePortPowerPriority and pethPsePortAdminEnable are objects of rfc3621-Power-Ethernet.mib.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0..100  

hh3cMainPseTable 1.3.6.1.4.1.25506.2.14.2
Description.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Hh3cMainPseEntry

hh3cMainPseEntry 1.3.6.1.4.1.25506.2.14.2.1
The pethMainPseGroupIndex is imported from the IETF Power MIB and uniquely identifies the group containing the port to which power ethernet PSE is connected. Group means (box in the stack, module in a rack) and the value 1 MUST be used for non-modular devices.
Status: current Access: not-accessible
OBJECT-TYPE    
  Hh3cMainPseEntry  

hh3cMainPsePowerLimit 1.3.6.1.4.1.25506.2.14.2.1.1
The object specifies the power limit set for the unit as a whole. The PoE unit will already have a nominal power defined by the IETF Power MIB [1] pethMainPsePower object. This OPTIONAL object specifies a further limit to this nominal power value. This may be useful to control the thermals of the unit, or for internal testing purposes. One possible use for this object may be to lower the power consumption of the unit if one or more of the internal fans have broken. It is a read/write integer value with units of Watts (note - Watts is chosen instead of milliWatts here since the IETF Power MIB [1] measures unit based parameters, such as the pethMainPsePower object, in units of Watts).
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

hh3cMainPseAveragePower 1.3.6.1.4.1.25506.2.14.2.1.2
The object specifies the average power which has been consumed by the port. It is a read/write integer value with units of Watts (note - Watts is chosen instead of milliWatts here since the IETF Power MIB [1] measures unit based parameters, such as the pethMainPsePower object, in units of Watts). Writing a value of zero to this object resets its value to zero. Writing any other value to this object has no effect on its value and an error is returned.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

hh3cMainPsePeakPower 1.3.6.1.4.1.25506.2.14.2.1.3
The object specifies the peak power which has been consumed for PoE. It is defined as the highest measured value of power in milliWatts that has been consumed at any one point in time by the sum of the PoE ports. Its value is only reset when the unit is powered on or when it is manually reset by the user as specifiedbelow. It is a read/write integer value with units of Watts (note - Watts is chosen instead of milliWatts here since the IETF Power MIB [1] measures unit based parameters, such as the pethMainPsePower object, in units of Watts). Writing a value of zero to this object resets its value to zero. Writing any other value to this object has noeffect on its value and an error is returned.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

hh3cMainGuaranteedPowerRemaining 1.3.6.1.4.1.25506.2.14.2.1.4
The object specifies the amount of power remaining in the guaranteed power pool. Each time a port is placed into guaranteed mode it reserves a set amount of power out of the total guaranteed power pool for the system. This intention of this object is to give the client of this MIB (whether that be the CLI or the Web interface or the end user) an indication of how many ports can still be placed into guaranteed mode. It is a read only integer value with units of Watts(note - Watts is chosen instead of milliWatts here since the IETF Power MIB [1] measures unit based parameters,such as the pethMainPsePower object, in units of Watts).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hh3cMainPsePriorityMode 1.3.6.1.4.1.25506.2.14.2.1.5
Describes or controls the priority mode on slot which must be enabled firstly. When a new board is inserted, and the power is over-load, a value of disconnection(0) means that the power will stop supply to the low priority slot ; A value of non-disconnection(1) means that the slot still supply when a new board is inserted, and the power is over-load too.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disconnection(0), non-disconnection(1)  

hh3cMainPseLegacy 1.3.6.1.4.1.25506.2.14.2.1.6
Describes or controls the legacy mode on slot which must be enabled firstly. Legacy mode: standard or nonstandard PD detection mode.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enable(0), disable(1)  

hh3cMainPsePowerPriority 1.3.6.1.4.1.25506.2.14.2.1.7
Describes or controls the priority of the PSE. The priority will be used by the PSE policy to prevent from power overloading. If the priority of PSE is set to critical, the PSE will turn into guaranteed mode. The priority could be used by a control mechanism that prevents power overloading by disconnecting PSEs with lower power priority. PSEs that connect devices critical to the application should be set to higher priority.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER critical(1), high(2), low(3)  

hh3cPseProfilesTable 1.3.6.1.4.1.25506.2.14.7
A table of objects representing a set of power profiles. Power profiles can be applied to PoE ports, which have the effect of automatically setting the priority, power limit and PoE enable MIB objects to the values specified in the power profile.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Hh3cPseProfilesEntry

hh3cPseProfilesEntry 1.3.6.1.4.1.25506.2.14.7.1
A set of objects that display and control the Main power of a PSE.
Status: current Access: not-accessible
OBJECT-TYPE    
  Hh3cPseProfilesEntry  

hh3cPseProfileIndex 1.3.6.1.4.1.25506.2.14.7.1.1
The index of the profile. This uniquely allow the profile to be identified.
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..100  

hh3cPseProfileName 1.3.6.1.4.1.25506.2.14.7.1.2
Assigns the profile a name with which the settings can be assiciated with. For example, 'NBX Phone'.
Status: current Access: read-create
OBJECT-TYPE    
  DisplayString Size(1..15)  

hh3cPseProfilePowerMode 1.3.6.1.4.1.25506.2.14.7.1.3
The power mode associated with this power profile. There are two possible power modes as follows: powerDisabled, powerEnabled. When a power profile is applied to a PSE port, this value dictates the settings of the ports pethPsePortPowerPriority and pethPsePortAdminEnable objects.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER powerDisabled(1), powerEnabled(2)  

hh3cPseProfilePowerLimit 1.3.6.1.4.1.25506.2.14.7.1.4
The power limit to be applied to the ports hh3cPsePortPowerLimit object when the profile is applied to the PSE port. Expressed in milliWatts.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32 0..15400  

hh3cPseProfilePriority 1.3.6.1.4.1.25506.2.14.7.1.5
This object controls the priority of the port from the point of view of a power management algorithm. The priority that is set by this variable could be used by a control mechanism that prevents over current situations by disconnecting first ports with lower power priority. Ports that connect devices critical to the operation of the network - like the E911 telephones ports - should be set to higher priority.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER critical(1), high(2), low(3)  

hh3cPseProfilePairs 1.3.6.1.4.1.25506.2.14.7.1.6
Describes or controls the pairs in use. If the value of pethPsePortPowerPairsControl is true, this object is writable. A value of signal(1) means that the signal pairs only are in use. A value of spare(2) means that the spare pairs only are in use.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER signal(1), spare(2)  

hh3cPseProfileApplyNum 1.3.6.1.4.1.25506.2.14.7.1.7
The number of this profile which has been applied. If hh3cPseProfileApplyNum is not zero, user can't change the current line.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hh3cPseProfileRowStatus 1.3.6.1.4.1.25506.2.14.7.1.8
The status of this classifier. If hh3cPseProfileApplyNum is not zero, user can't delete the current line.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

hh3cPseAutoDetectActive 1.3.6.1.4.1.25506.2.14.3
The object specifies whether the device auto-detection feature is active. If this object is set to Active, and a known powered device is detected, then the port will automatically switch to Auto-Guaranteed mode. This is a stackwide object (ie. it is not referenced by group index).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER notSupported(1), disabled(2), enabled(3)  

hh3cPsePowerMaxValue 1.3.6.1.4.1.25506.2.14.5
The object specifies the max poe power for lanswitch. The value should between the power currently and the max power.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

hh3cPsePolicyMode 1.3.6.1.4.1.25506.2.14.9
The PSE policy only applies to the situation that when a new board (PSE) is inserted, and the power is overload. A value of priority(2) means that the power will stop supplying to the low priority PSE. About PSE priority, please refer to hh3cMainPsePowerPriority. A value of disabled(1) means that the power will stop supplying to the new inserted PSE. The default value of this object is disabled(1).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), priority(2)  

hh3cPDPolicyMode 1.3.6.1.4.1.25506.2.14.10
The PD policy only applies to the situation that when a new PD is inserted, and the power of PSE is overload. A value of priority(2) means that the power will stop supplying to the low priority port PD. About port priority, please refer to pethPsePortPowerPriority. A value of disabled(1) means that the slot stop supplying to the new inserted PD. The default value of this object is disabled(1).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), priority(2)  

hh3cpseportNotification 1.3.6.1.4.1.25506.2.14.6
OBJECT IDENTIFIER    

hh3cpsePDChangeNotification 1.3.6.1.4.1.25506.2.14.6.1
This notification indicates if PD has been inserted or pulled out.
Status: current Access: read-write
NOTIFICATION-TYPE    

hh3cPOEDisconnectNotification 1.3.6.1.4.1.25506.2.14.6.2
This notification indicates the POE power module does not disconnect.
Status: current Access: read-write
NOTIFICATION-TYPE    

hh3cPOEInputErrorNotification 1.3.6.1.4.1.25506.2.14.6.3
This notification indicates the POE power module input error.
Status: current Access: read-write
NOTIFICATION-TYPE    

hh3cPOEOutputErrorNotification 1.3.6.1.4.1.25506.2.14.6.4
This notification indicates the POE power module output error.
Status: current Access: read-write
NOTIFICATION-TYPE    

hh3cPOEOverVoltageNotification 1.3.6.1.4.1.25506.2.14.6.5
This notification indicates the POE power module overruns the voltage limit.
Status: current Access: read-write
NOTIFICATION-TYPE    

hh3cPOEOverTempNotification 1.3.6.1.4.1.25506.2.14.6.6
This notification indicates the POE power module overruns the temperature limit.
Status: current Access: read-write
NOTIFICATION-TYPE    

hh3cPOEFanErrorNotification 1.3.6.1.4.1.25506.2.14.6.7
This notification indicates the POE power module fan error.
Status: current Access: read-write
NOTIFICATION-TYPE    

hh3cPOEModuleShutdownNotification 1.3.6.1.4.1.25506.2.14.6.8
This notification indicates the POE power module is closed.
Status: current Access: read-write
NOTIFICATION-TYPE    

hh3cPOECurRestrictedNotification 1.3.6.1.4.1.25506.2.14.6.9
This notification indicates the POE power module current is restricted.
Status: current Access: read-write
NOTIFICATION-TYPE    

hh3cPOEACSwitchNotification 1.3.6.1.4.1.25506.2.14.6.10
This notification indicates the AC input switch alarm of this POE power.
Status: current Access: read-write
NOTIFICATION-TYPE    

hh3cPOEACInCurANotification 1.3.6.1.4.1.25506.2.14.6.11
This notification indicates the AC input current A alarm state of this POE power.
Status: current Access: read-write
NOTIFICATION-TYPE    

hh3cPOEACInCurBNotification 1.3.6.1.4.1.25506.2.14.6.12
This notification indicates the AC input current B alarm state of this POE power.
Status: current Access: read-write
NOTIFICATION-TYPE    

hh3cPOEACInCurCNotification 1.3.6.1.4.1.25506.2.14.6.13
This notification indicates the AC input current C alarm state of this POE power.
Status: current Access: read-write
NOTIFICATION-TYPE    

hh3cPOEACSwitchVolABNotification 1.3.6.1.4.1.25506.2.14.6.14
This notification indicates the AC input voltage AB alarm state of this POE power.
Status: current Access: read-write
NOTIFICATION-TYPE    

hh3cPOEACSwitchVolBCNotification 1.3.6.1.4.1.25506.2.14.6.15
This notification indicates the AC input voltage BC alarm state of this POE power.
Status: current Access: read-write
NOTIFICATION-TYPE    

hh3cPOEACSwitchVolCANotification 1.3.6.1.4.1.25506.2.14.6.16
This notification indicates the AC input voltage CA alarm state of this POE power.
Status: current Access: read-write
NOTIFICATION-TYPE    

hh3cPOEDCOutVolNotification 1.3.6.1.4.1.25506.2.14.6.17
This notification indicates the DC output alarm of this POE power.
Status: current Access: read-write
NOTIFICATION-TYPE    

hh3cPOEShutdownNotification 1.3.6.1.4.1.25506.2.14.6.18
This notification indicates the whole POE power has been shutdown.
Status: current Access: read-write
NOTIFICATION-TYPE    

hh3cPseComformance 1.3.6.1.4.1.25506.2.14.4
OBJECT IDENTIFIER    

hh3cPseCompliances 1.3.6.1.4.1.25506.2.14.4.1
OBJECT IDENTIFIER    

hh3cPseCompliance 1.3.6.1.4.1.25506.2.14.4.1.1
Description.
Status: current Access: read-write
MODULE-COMPLIANCE    

hh3cPseGroup 1.3.6.1.4.1.25506.2.14.4.2
OBJECT IDENTIFIER    

hh3cPsePortGroup 1.3.6.1.4.1.25506.2.14.4.2.1
A collection of objects should be supported at the same time.
Status: current Access: read-write
OBJECT-GROUP    

hh3cMainPseGroup 1.3.6.1.4.1.25506.2.14.4.2.2
A collection of objects should be supported at the same time.
Status: current Access: read-write
OBJECT-GROUP    

hh3cPseScalarGroup 1.3.6.1.4.1.25506.2.14.4.2.3
A collection of scalar objects supported.
Status: current Access: read-write
OBJECT-GROUP    

hh3cPsePDNotificationGroup 1.3.6.1.4.1.25506.2.14.4.2.4
PD Change Notification.
Status: current Access: read-write
OBJECT-GROUP    

hh3cPseProfilesGroup 1.3.6.1.4.1.25506.2.14.4.2.5
A collection of objects should be supported at the same time.
Status: current Access: read-write
OBJECT-GROUP    

hh3cPOEPowerThresholdLimitGroup 1.3.6.1.4.1.25506.2.14.4.2.6
Power threshold limits group.
Status: current Access: read-write
OBJECT-GROUP    

hh3cPOEPowerSupInfoGroup 1.3.6.1.4.1.25506.2.14.4.2.7
The basic Power information group.
Status: current Access: read-write
OBJECT-GROUP    

hh3cPOEPowerDCOutStateGroup 1.3.6.1.4.1.25506.2.14.4.2.8
The DC out power state group.
Status: current Access: read-write
OBJECT-GROUP    

hh3cPOEPowerDCOutInfoGroup 1.3.6.1.4.1.25506.2.14.4.2.9
The power AC input switch information group
Status: current Access: read-write
OBJECT-GROUP    

hh3cPOEPowerACSwitchStateModuleGroup 1.3.6.1.4.1.25506.2.14.4.2.10
PD Change Notification.
Status: current Access: read-write
OBJECT-GROUP    

hh3cPOEPowerInCurStateGroup 1.3.6.1.4.1.25506.2.14.4.2.11
PD Change Notification.
Status: current Access: read-write
OBJECT-GROUP    

hh3cPOEPowerAlarmStateGroup 1.3.6.1.4.1.25506.2.14.4.2.12
PD Change Notification.
Status: current Access: read-write
OBJECT-GROUP    

hh3cPOEPowerObjects 1.3.6.1.4.1.25506.2.14.8
OBJECT IDENTIFIER    

hh3cPOEThresholdLimitObjs 1.3.6.1.4.1.25506.2.14.8.1
OBJECT IDENTIFIER    

hh3cPOEThresholdACMimimum 1.3.6.1.4.1.25506.2.14.8.1.1
Input threshold AC minimum. It is a read-write node. The value of this node is 'OCTET STRING', it is used to describe a float value. So this string should fit the following rule: 1. This string should be terminated by ''; 2. Every characters should be number or radix point; 3. The radix point should occur only once, and it should not be the first or the last character of the string. The value of this node should be smaller than 264.0V and larger than 90.0V. And it should be smaller than the hh3cPOEThresholdACMaximum.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1..10)  

hh3cPOEThresholdACMaximum 1.3.6.1.4.1.25506.2.14.8.1.2
Input threshold AC maximum. It is a read-write node. The value of this node is 'OCTET STRING', it is used to describe a float value. So this string should fit the following rule: 1. This string should be terminated by ''; 2. Every characters should be number or radix point; 3. The radix point should occur only once, and it should not be the first or the last character of the string. It should be smaller than 264.0V and larger than 90.0V. And it should be larger than the hh3cPOEThresholdACMinimum.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1..10)  

hh3cPOEThresholdDCMinimum 1.3.6.1.4.1.25506.2.14.8.1.3
Input threshold DC minimum. It is a read-write node. The value of this node is 'OCTET STRING', it is used to describe a float value. So this string should fit the following rule: 1. This string should be terminated by ''; 2. Every characters should be number or radix point; 3. The radix point should occur only once, and it should not be the first or the last character of the string. It should be smaller than 47.0V and larger than 45.0V.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1..10)  

hh3cPOEThresholdDCMaximum 1.3.6.1.4.1.25506.2.14.8.1.4
Input threshold DC maximum. It is a read-write node. The value of this node is 'OCTET STRING', it is used to describe a float value. So this string should fit the following rule: 1. This string should be terminated by ''; 2. Every characters should be number or radix point; 3. The radix point should occur only once, and it should not be the first or the last character of the string. It should be smaller than 57.0V and larger than 55.0V.
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(1..10)  

hh3cPOESupModuleInfoObjs 1.3.6.1.4.1.25506.2.14.8.2
OBJECT IDENTIFIER    

hh3cPOEPowerType 1.3.6.1.4.1.25506.2.14.8.2.1
The type of the power.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(1..127)  

hh3cPOEPowerModuleNum 1.3.6.1.4.1.25506.2.14.8.2.2
The number of the power modules.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hh3cPOESupervisionModuleName 1.3.6.1.4.1.25506.2.14.8.2.3
The object specifies the Supervision Module name on this POE power.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(1..127)  

hh3cPOESMMajorVersion 1.3.6.1.4.1.25506.2.14.8.2.4
The object specifies the high byte of the monitor module version.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hh3cPOESMMinorVersion 1.3.6.1.4.1.25506.2.14.8.2.5
The object specifies the low byte of the monitor module version.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hh3cPOESMFactorName 1.3.6.1.4.1.25506.2.14.8.2.6
The object specifies the name of the manufactor.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(1..127)  

hh3cPOEModuleInfoTable 1.3.6.1.4.1.25506.2.14.8.2.7
The table of the module information on this POE power.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Hh3cPOEModuleInfoEntry

hh3cPOEModuleInfoEntry 1.3.6.1.4.1.25506.2.14.8.2.7.1
The entry of the module information on this POE power.
Status: current Access: not-accessible
OBJECT-TYPE    
  Hh3cPOEModuleInfoEntry  

hh3cPOEModuleIndex 1.3.6.1.4.1.25506.2.14.8.2.7.1.1
The index of the current module on this POE power. It is also the index of hh3cPOEModuleInfoTable. The range of this node is from 1 to hh3cPOEPowerModuleNum.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32 1..2147483647  

hh3cPOEModuleID 1.3.6.1.4.1.25506.2.14.8.2.7.1.2
The ID of the current module on this POE power.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hh3cPOEModuleInfoPower 1.3.6.1.4.1.25506.2.14.8.2.7.1.3
The power of the current module on this POE power.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hh3cPOEModuleHardVerInfo 1.3.6.1.4.1.25506.2.14.8.2.7.1.4
The hardware version information of the current module on this POE power.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(1..127)  

hh3cPOEDCOutStateObjects 1.3.6.1.4.1.25506.2.14.8.3
OBJECT IDENTIFIER    

hh3cPOEDCOutStateModuleNum 1.3.6.1.4.1.25506.2.14.8.3.1
The module number on this POE power. It is the maximum of the hh3cPOEDCOutStateIndex.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hh3cPOEDCOutStateTable 1.3.6.1.4.1.25506.2.14.8.3.2
The table of DC output power state on this POE power.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Hh3cPOEDCOutStateEntry

hh3cPOEDCOutStateEntry 1.3.6.1.4.1.25506.2.14.8.3.2.1
The entry of the DC output power state on this POE power.
Status: current Access: not-accessible
OBJECT-TYPE    
  Hh3cPOEDCOutStateEntry  

hh3cPOEDCOutStateIndex 1.3.6.1.4.1.25506.2.14.8.3.2.1.1
The index of the DC output power state on this POE power. The range of this node is from 1 to hh3cPOEDCOutStateModuleNum.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32 1..2147483647  

hh3cPOEDCOutDCVolAlarm 1.3.6.1.4.1.25506.2.14.8.3.2.1.2
The DC output alarm of the DC output power state on this POE power. The value of this node will be the following values: normal (1), underLimit (2), aboveLimit (3), fuseBroken (4), switchOff (5), otherError (6).
Status: current Access: read-only
OBJECT-TYPE    
  DCAlarmState  

hh3cPOEDCOutInfoObjects 1.3.6.1.4.1.25506.2.14.8.4
OBJECT IDENTIFIER    

hh3cPOEDCOutCurNum 1.3.6.1.4.1.25506.2.14.8.4.1
The number of DC output current on this POE power. It is the maximum of hh3cPOEDCOutInfoIndex.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hh3cPOEDCOutInfoTable 1.3.6.1.4.1.25506.2.14.8.4.2
The table of the DC output information on this POE power.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Hh3cPOEDCOutInfoEntry

hh3cPOEDCOutInfoEntry 1.3.6.1.4.1.25506.2.14.8.4.2.1
The entry of the DC output information on this POE power.
Status: current Access: not-accessible
OBJECT-TYPE    
  Hh3cPOEDCOutInfoEntry  

hh3cPOEDCOutInfoIndex 1.3.6.1.4.1.25506.2.14.8.4.2.1.1
The index of the DC output information on this POE POWER. The range of this node is from 1 to hh3cPOEDCOutCurNum.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32 1..2147483647  

hh3cPOEDCOutVol 1.3.6.1.4.1.25506.2.14.8.4.2.1.2
The DC output voltage of the current DC output on this POE power.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(1..10)  

hh3cPOEDCOutInfoLoadCur 1.3.6.1.4.1.25506.2.14.8.4.2.1.3
The total load current of the current DC output on this POE power.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(1..10)  

hh3cPOEACSwitchStateModuleObjs 1.3.6.1.4.1.25506.2.14.8.5
OBJECT IDENTIFIER    

hh3cPOEACSwitchStateModuleNum 1.3.6.1.4.1.25506.2.14.8.5.1
The number of the AC swtich state module on this POE power. It is the maximum of hh3cPOEACSwitchStateIndex.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hh3cPOEACSwitchStateTable 1.3.6.1.4.1.25506.2.14.8.5.2
The table of the AC switch state on this POE power.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Hh3cPOEACSwitchStateEntry

hh3cPOEACSwitchStateEntry 1.3.6.1.4.1.25506.2.14.8.5.2.1
The entry of the AC switch state on this POE power.
Status: current Access: not-accessible
OBJECT-TYPE    
  Hh3cPOEACSwitchStateEntry  

hh3cPOEACSwitchStateIndex 1.3.6.1.4.1.25506.2.14.8.5.2.1.1
The index of the AC switch state on this POE power. The range of this node is from 1 to hh3cPOEACSwitchStateModuleNum.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32 1..2147483647  

hh3cPOEACSwitchState 1.3.6.1.4.1.25506.2.14.8.5.2.1.2
The AC switch state on this POE power. The value of this node will be one of the following values: on (1), off (2), highVoltInput (3), lowVoltInput (4)
Status: current Access: read-only
OBJECT-TYPE    
  SwitchState  

hh3cPOEInCurStateObjects 1.3.6.1.4.1.25506.2.14.8.6
OBJECT IDENTIFIER    

hh3cPOEInCurStateModuleNum 1.3.6.1.4.1.25506.2.14.8.6.1
The DC input current state of the module on this POE power. It is the maximum of the hh3cPOESwitchStateVolExIndex.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hh3cPOEInCurAState 1.3.6.1.4.1.25506.2.14.8.6.2
The current A state in the DC input on this POE power. normal (1), underLimit (2), aboveLimit (3), lackPhrase (4), fuseBroken (5), switchOff (6), otherError (7).
Status: current Access: read-only
OBJECT-TYPE    
  ACAlarmState  

hh3cPOEInCurBState 1.3.6.1.4.1.25506.2.14.8.6.3
The current B state in the DC input on this POE power. The value of this node will be one of the following values: normal (1), underLimit (2), aboveLimit (3), lackPhrase (4), fuseBroken (5), switchOff (6), otherError (7).
Status: current Access: read-only
OBJECT-TYPE    
  ACAlarmState  

hh3cPOEInCurCState 1.3.6.1.4.1.25506.2.14.8.6.4
The current C state in the DC input on this POE power. The value of this node will be one of the following values: normal (1), underLimit (2), aboveLimit (3), lackPhrase (4), fuseBroken (5), switchOff (6), otherError (7).
Status: current Access: read-only
OBJECT-TYPE    
  ACAlarmState  

hh3cPOESwitchStateVolExTable 1.3.6.1.4.1.25506.2.14.8.6.5
All alarm status of the VOL status. The value of this node will be one of the following values: normal (1), underLimit (2), aboveLimit (3), lackPhrase (4), fuseBroken (5), switchOff (6), otherError (7).
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Hh3cPOESwitchStateVolExEntry

hh3cPOESwitchStateVolExEntry 1.3.6.1.4.1.25506.2.14.8.6.5.1
The hh3cPOESwitchStateVolExIndex will match the number of the VOL status.
Status: current Access: not-accessible
OBJECT-TYPE    
  Hh3cPOESwitchStateVolExEntry  

hh3cPOESwitchStateVolExIndex 1.3.6.1.4.1.25506.2.14.8.6.5.1.1
The object species the index of the VOL status. The range of this node is from 1 to hh3cPOEInCurStateModuleNum.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32 1..2147483647  

hh3cPOESwitchStateInVolAB 1.3.6.1.4.1.25506.2.14.8.6.5.1.2
The object specifies the VOL AB alarm in each VOL status. The value of this node will be one of the following values: normal (1), underLimit (2), aboveLimit (3), lackPhrase (4), fuseBroken (5), switchOff (6), otherError (7).
Status: current Access: read-only
OBJECT-TYPE    
  ACAlarmState  

hh3cPOESwitchStateInVolBC 1.3.6.1.4.1.25506.2.14.8.6.5.1.3
The object specifies the VOL BC alarm in each VOL status. The value of this node will be one of the following values: normal (1), underLimit (2), aboveLimit (3), lackPhrase (4), fuseBroken (5), switchOff (6), otherError (7).
Status: current Access: read-only
OBJECT-TYPE    
  ACAlarmState  

hh3cPOESwitchStateInVolCA 1.3.6.1.4.1.25506.2.14.8.6.5.1.4
The object specifies the VOL CA alarm in each VOL status. The value of this node will be one of the following values: normal (1), underLimit (2), aboveLimit (3), lackPhrase (4), fuseBroken (5), switchOff (6), otherError (7).
Status: current Access: read-only
OBJECT-TYPE    
  ACAlarmState  

hh3cPOEAlarmStateObjects 1.3.6.1.4.1.25506.2.14.8.7
OBJECT IDENTIFIER    

hh3cPOEAlarmStateModuleNum 1.3.6.1.4.1.25506.2.14.8.7.1
The object specifies the number of the power modules in alarm state.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

hh3cPOEAlarmStateInfoTable 1.3.6.1.4.1.25506.2.14.8.7.2
All alarm states in the POE power modules.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Hh3cPOEAlarmStateInfoEntry

hh3cPOEAlarmStateInfoEntry 1.3.6.1.4.1.25506.2.14.8.7.2.1
The hh3cPOEAlarmModuleInfoIndex will match the number of the power module.
Status: current Access: not-accessible
OBJECT-TYPE    
  Hh3cPOEAlarmStateInfoEntry  

hh3cPOEAlarmModuleInfoIndex 1.3.6.1.4.1.25506.2.14.8.7.2.1.1
The index specifies the index of the Hh3cPOEAlarmStateInfoEntry table. The range of this node is from 1 to hh3cPOEAlarmStateModuleNum.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  Integer32 1..2147483647  

hh3cPOEModuleDisconnect 1.3.6.1.4.1.25506.2.14.8.7.2.1.2
The node specifies the alarm state: The module does not link. The value of this node is one of the following values: normal (1), alarm (2).
Status: current Access: read-only
OBJECT-TYPE    
  ModuleAlarmState  

hh3cPOEModuleInputError 1.3.6.1.4.1.25506.2.14.8.7.2.1.3
The node specifies the alarm state: Input error. The value of this node is one of the following values: normal (1), alarm (2).
Status: current Access: read-only
OBJECT-TYPE    
  ModuleAlarmState  

hh3cPOEModuleOutputError 1.3.6.1.4.1.25506.2.14.8.7.2.1.4
The node specifies the alarm state: Output error. The value of this node is one of the following values: normal (1), alarm (2).
Status: current Access: read-only
OBJECT-TYPE    
  ModuleAlarmState  

hh3cPOEModuleOverVoltage 1.3.6.1.4.1.25506.2.14.8.7.2.1.5
The node specifies the alarm state: The voltage is too high. The value of this node is one of the following values: normal (1), alarm (2).
Status: current Access: read-only
OBJECT-TYPE    
  ModuleAlarmState  

hh3cPOEModuleOverTemp 1.3.6.1.4.1.25506.2.14.8.7.2.1.6
The node specifies the alarm state: The temperature is too high. The value of this node is one of the following values: normal (1), alarm (2).
Status: current Access: read-only
OBJECT-TYPE    
  ModuleAlarmState  

hh3cPOEModuleFanError 1.3.6.1.4.1.25506.2.14.8.7.2.1.7
The node specifies the alarm state: The fan error. The value of this node is one of the following values: normal (1), alarm (2).
Status: current Access: read-only
OBJECT-TYPE    
  ModuleAlarmState  

hh3cPOEModuleShutdown 1.3.6.1.4.1.25506.2.14.8.7.2.1.8
The node specifies the alarm state: The module is shutdown. The value of this node is one of the following values: normal (1), alarm (2).
Status: current Access: read-only
OBJECT-TYPE    
  ModuleAlarmState  

hh3cPOEModuleCurRestricted 1.3.6.1.4.1.25506.2.14.8.7.2.1.9
The node specifies the alarm state: The module limit the current. The value of this node is one of the following values: normal (1), alarm (2).
Status: current Access: read-only
OBJECT-TYPE    
  ModuleAlarmState