GDC-SC800T3-MIB

File: GDC-SC800T3-MIB.mib (88791 bytes)

Imported modules

RFC-1212 RFC1213-MIB GDCCMN-MIB
GDCMACRO-MIB

Imported symbols

OBJECT-TYPE DisplayString gdc
SCinstance

Defined Types

Sc800t3VersionEntry  
SEQUENCE    
  sc800t3VersionIndex SCinstance
  sc800t3ActiveFirmwareRev DisplayString
  sc800t3StandbyFirmwareRev DisplayString
  sc800t3StoredFirmwareStatus INTEGER
  sc800t3SwitchActiveFirmware INTEGER
  sc800t3DownloadingMode INTEGER
  sc800t3EraseFlash INTEGER

Sc800t3ChannelConfigEntry  
SEQUENCE    
  sc800t3ChannelConfigIndex SCinstance
  sc800t3ForcedDCE INTEGER
  sc800t3ChannelDTEtest INTEGER
  sc800t3DTELoopTimeout INTEGER

Sc800t3NetworkConfigEntry  
SEQUENCE    
  sc800t3NetworkConfigIndex SCinstance
  sc800t3NetworkFrameType INTEGER
  sc800t3NetworkTransmitClockSource INTEGER
  sc800t3NetworkAISLoopdown INTEGER
  sc800t3NetworkLineType INTEGER
  sc800t3NetworkIdleStatus INTEGER
  sc800t3NetworkTransmitIdleStatus INTEGER
  sc800t3NetworkSesBERThreshold INTEGER
  sc800t3InbandLoopback INTEGER

Sc800t3DiagEntry  
SEQUENCE    
  sc800t3DiagIndex SCinstance
  sc800t3DiagTestDuration INTEGER
  sc800t3InsertBitError INTEGER
  sc800t3DiagT3Test INTEGER
  sc800t3DiagTestResults OCTET STRING
  sc800t3DiagResetTestResults INTEGER

Sc800t3MaintenanceEntry  
SEQUENCE    
  sc800t3MaintenanceIndex SCinstance
  sc800t3LedStatus OCTET STRING
  sc800t3SoftReset INTEGER
  sc800t3DefaultInit INTEGER
  sc800t3ValidNearEndIntervals INTEGER
  sc800t3ValidFarEndIntervals INTEGER
  sc800t3ShelfType INTEGER
  sc800t3TwinPackPowerSupply INTEGER
  sc800t3TestAllLeds INTEGER
  sc800t3NearEndResetStats INTEGER
  sc800t3FarEndResetStats INTEGER
  sc800t3NearEndStatLastInitial INTEGER
  sc800t3FarEndStatLastInitial INTEGER

Sc800t3AlarmConfigEntry  
SEQUENCE    
  sc800t3AlarmConfigIndex SCinstance
  sc800t3AlarmConfigIdentifier OBJECT IDENTIFIER
  sc800t3AlarmCountWindow INTEGER
  sc800t3AlarmCountThreshold INTEGER

Sc800t3CurrentNearEndEntry  
SEQUENCE    
  sc800t3CurrentNearEndIndex SCinstance
  sc800t3CurrentNearEndStat OCTET STRING

Sc800t3CurrentFarEndEntry  
SEQUENCE    
  sc800t3CurrentFarEndIndex SCinstance
  sc800t3CurrentFarEndStat OCTET STRING

Sc800t3CurrentDayNearEndEntry  
SEQUENCE    
  sc800t3CurrentDayNearEndIndex SCinstance
  sc800t3CurrentDayNearEndStat OCTET STRING

Sc800t3CurrentDayFarEndEntry  
SEQUENCE    
  sc800t3CurrentDayFarEndIndex SCinstance
  sc800t3CurrentDayFarEndStat OCTET STRING

Sc800t3PreviousDayNearEndEntry  
SEQUENCE    
  sc800t3PreviousDayNearEndIndex SCinstance
  sc800t3PreviousDayNearEndStat OCTET STRING

Sc800t3PreviousDayFarEndEntry  
SEQUENCE    
  sc800t3PreviousDayFarEndIndex SCinstance
  sc800t3PreviousDayFarEndStat OCTET STRING

Sc800t3NearEndIntervalEntry  
SEQUENCE    
  sc800t3NearEndIntervalIndex SCinstance
  sc800t3NearEndIntervalNumber INTEGER
  sc800t3NearEndIntervalStats OCTET STRING

Sc800t3FarEndIntervalEntry  
SEQUENCE    
  sc800t3FarEndIntervalIndex SCinstance
  sc800t3FarEndIntervalNumber INTEGER
  sc800t3FarEndIntervalStats OCTET STRING

Sc800t3PreviousNearEndEntry  
SEQUENCE    
  sc800t3PreviousNearEndIndex SCinstance
  sc800t3PreviousNearEndStat OCTET STRING

Sc800t3PreviousFarEndEntry  
SEQUENCE    
  sc800t3PreviousFarEndIndex SCinstance
  sc800t3PreviousFarEndStat OCTET STRING

Sc800t3LocalAlarmConfigEntry  
SEQUENCE    
  sc800t3LocalAlarmConfigIndex SCinstance
  sc800t3OOF INTEGER
  sc800t3AISLOCAL INTEGER
  sc800t3TIMLOS INTEGER
  sc800t3TXDLOS INTEGER
  sc800t3RXDLOS INTEGER
  sc800t3LOS INTEGER
  sc800t3TPSFAIL INTEGER
  sc800t3BPSFAIL INTEGER
  sc800t3DTECLKLOS INTEGER
  sc800t3DTERDYLOS INTEGER
  sc800t3RAILOCAL INTEGER
  sc800t3THRESHESL INTEGER
  sc800t3THRESHES INTEGER
  sc800t3THRESHSES INTEGER
  sc800t3THRESHSAS INTEGER
  sc800t3THRESHUAS INTEGER
  sc800t3THRESHCV INTEGER

Defined Values

ds3 1.3.6.1.4.1.498.19
OBJECT IDENTIFIER    

sc800t3 1.3.6.1.4.1.498.19.1
OBJECT IDENTIFIER    

sc800t3Version 1.3.6.1.4.1.498.19.1.1
OBJECT IDENTIFIER    

sc800t3Configuration 1.3.6.1.4.1.498.19.1.2
OBJECT IDENTIFIER    

sc800t3Diagnostics 1.3.6.1.4.1.498.19.1.3
OBJECT IDENTIFIER    

sc800t3Maintenance 1.3.6.1.4.1.498.19.1.4
OBJECT IDENTIFIER    

sc800t3Alarms 1.3.6.1.4.1.498.19.1.5
OBJECT IDENTIFIER    

sc800t3Performance 1.3.6.1.4.1.498.19.1.6
OBJECT IDENTIFIER    

sc800t3AlarmConfig 1.3.6.1.4.1.498.19.1.7
OBJECT IDENTIFIER    

sc800t3LocalAlarms 1.3.6.1.4.1.498.19.1.8
OBJECT IDENTIFIER    

sc800t3MIBversion 1.3.6.1.4.1.498.19.1.1.1
Identifies the version of the MIB. The format of the version is x.yzT, where 'x' identifies the major revision number, 'y' identifies the minor revision number, 'z' identifies the typographical revision, and T identifies the test revision. Upon formal release, no designation for the test revision will be present. Acceptable values for the individual revision components are as follows: x: 1 - 9, y: 0 - 9, z: 0 - 9, T: A - Z
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(5)  

sc800t3VersionTable 1.3.6.1.4.1.498.19.1.1.2
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Sc800t3VersionEntry

sc800t3VersionEntry 1.3.6.1.4.1.498.19.1.1.2.1
An entry in the GDC SC800T3 Version Table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Sc800t3VersionEntry  

sc800t3VersionIndex 1.3.6.1.4.1.498.19.1.1.2.1.1
Integer value which uniquely identifies the SC800T3 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf slot location (01-32) L (byte value) - line number (01) D (byte value) - drop number (00) i (byte value) - interface number (00)
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

sc800t3ActiveFirmwareRev 1.3.6.1.4.1.498.19.1.1.2.1.2
The version number of the firmware currently executing. The format is MM.NN.BB where: MM: Major Revision (0-99) NN: Minor Revision (0-99) BB: Bug Fix Revision (0-99)
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(8)  

sc800t3StandbyFirmwareRev 1.3.6.1.4.1.498.19.1.1.2.1.3
The version number of the firmware stored (in a compressed format) but not currently executing. MM: Major Revision (0-99) NN: Minor Revision (0-99) BB: Bug Fix Revision (0-99)
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(8)  

sc800t3StoredFirmwareStatus 1.3.6.1.4.1.498.19.1.1.2.1.4
This object represents the state of the Non-Active or Stored firmware: statBlank(1) Factory Default statDownLoading(2) In process of downloading firmware statOK(3) Zipped version checksum succesful (OK to switch) (can set sc800t3SwitchActive to switchActive(2)) statCheckSumBad(4) Failed checksum after download statUnZipping(5) In process of uncompressing into active area statBadUnZip(6) Failed last uncompress statDownloadAborted(7) Download aborted by user
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER statBlank(1), statDownLoading(2), statOK(3), statCheckSumBad(4), statUnZipping(5), statBadUnZip(6), statDownloadAborted(7)  

sc800t3SwitchActiveFirmware 1.3.6.1.4.1.498.19.1.1.2.1.5
This object is used to switch the active executing firmware from the version in sc800t3ActiveRev to the version in sc800t3StoredRev. When a switchActive(2) is set (write only) the element will: 1) reboot 2) uncompress stored code into active area 3) perform checksum on active area 4) Set sc800t3StoredStatus object to indicate results 5) If succesfull: update sc800t3ActiveFirmwareRev and sc800t3StoredFirmwareRev and begin executing If failed: replace active area with previous revision The switchNorm(1) enumeration will always be read. Setting switchActive(2) when the sc800t3StoredStatus is not statOK(3) will result in an error.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER switchNorm(1), switchActive(2)  

sc800t3DownloadingMode 1.3.6.1.4.1.498.19.1.1.2.1.6
This object is used to configure the download mode: disableAll(1) Prevents any firmware downloading to SC800T3 enableAndWait(2) Allows downloading zipped code to be stored only! enableAndSwitch(3) Allows downloading and then unzips and begins executing the new code
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disableAll(1), enableAndWait(2), enableAndSwitch(3)  

sc800t3EraseFlash 1.3.6.1.4.1.498.19.1.1.2.1.7
A set of this object to erase(2) will erase the application stored in flash. After setting this object, there should be a delay of at least 2 minutes before downloading the unit.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER normal(1), erase(2)  

sc800t3ChannelConfigTable 1.3.6.1.4.1.498.19.1.2.1
The GDC SC800T3 Channel Configuration table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Sc800t3ChannelConfigEntry

sc800t3ChannelConfigEntry 1.3.6.1.4.1.498.19.1.2.1.1
The sc800t3 Channel Configuration table entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Sc800t3ChannelConfigEntry  

sc800t3ChannelConfigIndex 1.3.6.1.4.1.498.19.1.2.1.1.1
Integer value which uniquely identifies the SC800T3 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf slot location (01-32) L (byte value) - line number (01) D (byte value) - drop number (00) i (byte value) - interface number (00)
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

sc800t3ForcedDCE 1.3.6.1.4.1.498.19.1.2.1.1.2
Controls the operation of Data Communications Equipment (DCE) signal. The value followsDte(1) indicates that the channel's DCE follows Data Terminal Equipment (DTE) ready. The value forcedOn(2) indicates that DCE is forced on.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER followsDte(1), forcedOn(2)  

sc800t3ChannelDTEtest 1.3.6.1.4.1.498.19.1.2.1.1.3
DTE interface supporting loop A and loop B tests. See ANSI TIA/EIA-613-1993 specification for details on encoding of inter changes.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

sc800t3DTELoopTimeout 1.3.6.1.4.1.498.19.1.2.1.1.4
Enables/disables DTE loop time out.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

sc800t3NetworkConfigTable 1.3.6.1.4.1.498.19.1.2.2
The GDC SC800T3 Network Configuration table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Sc800t3NetworkConfigEntry

sc800t3NetworkConfigEntry 1.3.6.1.4.1.498.19.1.2.2.1
The sc800t3 Network Configuration table entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Sc800t3NetworkConfigEntry  

sc800t3NetworkConfigIndex 1.3.6.1.4.1.498.19.1.2.2.1.1
Integer value which uniquely identifies the SC800T3 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf slot location (01-32) L (byte value) - line number (01) D (byte value) - drop number (00) i (byte value) - interface number (00)
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

sc800t3NetworkFrameType 1.3.6.1.4.1.498.19.1.2.2.1.2
Is the framing type of the network interface. Setting the value of the object to m13(1) configures the network interface to M-13 framing. Setting the value of this object to cbitParity configures the network interface 20 C-bit parity framing
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER m13(1), cbitParity(2)  

sc800t3NetworkTransmitClockSource 1.3.6.1.4.1.498.19.1.2.2.1.3
The DSU transmit clock source option. This is the selection for the transmitter timing clock source.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER internal(1), receive(2)  

sc800t3NetworkAISLoopdown 1.3.6.1.4.1.498.19.1.2.2.1.4
The time in seconds when receiving a continuous AIS signal before a remotely initiated loopback is terminated. When this object has the value 4, then there is no time limit and the loop must be terminated by remotely issued in-band loopdown codes. When the object has a value between 5 and 60, then this is time in seconds of continuous AIS signal before the loopback is terminated.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 4..60  

sc800t3NetworkLineType 1.3.6.1.4.1.498.19.1.2.2.1.5
The operating mode of the interface. Setting the value of this object to longCable(1) configures the interface as standard DS-3. Setting the value of this object to shortCable(2) configures the interface to operate as a standard cross-connect DSX-3.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER longCable(1), shortCable(2)  

sc800t3NetworkIdleStatus 1.3.6.1.4.1.498.19.1.2.2.1.6
Returns a value of received(2) when the sc800t3 receives a DS3 idle from the network.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notReceived(1), received(2)  

sc800t3NetworkTransmitIdleStatus 1.3.6.1.4.1.498.19.1.2.2.1.7
When set to active(2), the sc800t3 will transmit a DS3 idle signal to the network.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER inactive(1), active(2)  

sc800t3NetworkSesBERThreshold 1.3.6.1.4.1.498.19.1.2.2.1.8
When set to thresone(1), the SES BER threshold will be set to 1X10^-6 and when it is set to thresseven(2), it will be set to 7.5X10^-5.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER thresone(1), thresseven(2)  

sc800t3InbandLoopback 1.3.6.1.4.1.498.19.1.2.2.1.9
Enables/disables the inband loop back.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2)  

sc800t3DiagTable 1.3.6.1.4.1.498.19.1.3.1
The SC800T3 Diagnostics table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Sc800t3DiagEntry

sc800t3DiagEntry 1.3.6.1.4.1.498.19.1.3.1.1
The SNMPSC800T3 Diagnostics table entry.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Sc800t3DiagEntry  

sc800t3DiagIndex 1.3.6.1.4.1.498.19.1.3.1.1.1
Integer value which uniquely identifies the SC800T3 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf slot location (01-32) L (byte value) - line number (01) D (byte value) - drop number (00) i (byte value) - interface number (00)
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

sc800t3DiagTestDuration 1.3.6.1.4.1.498.19.1.3.1.1.2
Selects the duration to run a diagnostic test.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER testTime30Secs(1), testTime1Min(2), testTime2Mins(3), testTime3Mins(4), testTime4Mins(5), testTime5Mins(6), testTime6Mins(7), testTime7Mins(8), testTime8Mins(9), testTime9Mins(10), testTime10Mins(11), testTime15Mins(12), testTime20Mins(13), testTime25Mins(14), testTime30Mins(15), testTimeInfinite(16)  

sc800t3InsertBitError 1.3.6.1.4.1.498.19.1.3.1.1.3
A set of 2 will insert one bit error for test. Management may only write a 2. A 1 will always be read.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER insertBitErrorNorm(1), insertOneBitError(2)  

sc800t3DiagT3Test 1.3.6.1.4.1.498.19.1.3.1.1.4
A set of 2-11 starts the specified test and a set of t3NoTest(1) stops the current running test. A get returns the current active test.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER t3NoTest(1), t3LineLoopback(2), t3PayLoadLoopback(3), t3LocalLoopback(4), t3LocalLoopbackST(5), t3DTELoopback(6), t3RemoteLineLoopback(7), t3RemoteLineLoopbackST(8), t3RemotePayload(9), t3RemotePayloadST(10), t3EndToEndST(11)  

sc800t3DiagTestResults 1.3.6.1.4.1.498.19.1.3.1.1.5
Returns a the folowing bytes. Octet 1 bit 7 - F/U bit 6 - 1: Test complete bit 5 - 1: Test aborted bit 4 - F/U bit 3 - remote status 0: inactive 1: active bit 2 - 1: Bit errors over range bit 1 - Bit Errors bit 0 - Bit Errors Octet 2 bit 7 - F/U bit 6 - 2^13 bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 Bit Error Count bit 1 - 2^8 bit 0 - 2^7 Octet 3 bit 7 - F/U bit 6 - 2^6 bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(3)  

sc800t3DiagResetTestResults 1.3.6.1.4.1.498.19.1.3.1.1.6
This object will clear the results register while running any test except for Network Delay. Starting a new test will automatically zero out the register. A normal(1) will always be read. Management will set a resetTestResult(2) to reset the test results.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER normal(1), resetTestResult(2)  

sc800t3MaintenanceTable 1.3.6.1.4.1.498.19.1.4.1
The table describes the maintenance functions for the sc800t3.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Sc800t3MaintenanceEntry

sc800t3MaintenanceEntry 1.3.6.1.4.1.498.19.1.4.1.1
An entry in the GDC maintenance Table
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Sc800t3MaintenanceEntry  

sc800t3MaintenanceIndex 1.3.6.1.4.1.498.19.1.4.1.1.1
Integer value which uniquely identifies the SC800T3 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf slot location (01-32) L (byte value) - line number (01) D (byte value) - drop number (00) i (byte value) - interface number (00)
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

sc800t3LedStatus 1.3.6.1.4.1.498.19.1.4.1.1.2
Returns a bitwise snapshot of the front panel LED state and front panel switches. Octet 1 bit 7 - f/u bit 6 - NTWK 0:LED off 1:LED on bit 5 - TM 0:LED off 1:LED on bit 4 - ALM 0:LED off 1:LED on bit 3 - f/u bit 2 - f/u bit 1 - f/u bit 0 - f/u Octet 2 bit 7 - f/u bit 6 - f/u bit 5 - f/u bit 4 - f/u bit 3 - f/u bit 2 - f/u bit 1 - f/u bit 0 - f/u Octet 3 bit 7 - f/u bit 6 - f/u bit 5 - f/u bit 4 - f/u bit 3 - f/u bit 2 - f/u bit 1 - f/u bit 0 - f/u
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(3)  

sc800t3SoftReset 1.3.6.1.4.1.498.19.1.4.1.1.3
Supports the action of soft resetting the unit. When this object is set to reset(1), then the unit performs a soft reset. The value norm will be returned when the reset is complete. The value of norm can not be set by management.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER norm(1), reset(2)  

sc800t3DefaultInit 1.3.6.1.4.1.498.19.1.4.1.1.4
This is used to allow the NonVolatile Configuration to be set to a factory default state. When this value is set to factoryDefault, the unit will reset to the default configuration. The value of normal will be returned when the initialization is complete. The value normal can not be set by management.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER normal(1), factoryDefault(2)  

sc800t3ValidNearEndIntervals 1.3.6.1.4.1.498.19.1.4.1.1.5
The number of previous near end intervals for which valid data was collected. The value will be 31 unless the interface was brought on-line within the last 7.75 hours, in which case the value will be the number of complete 15 minute intervals since the interface has been online.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..31  

sc800t3ValidFarEndIntervals 1.3.6.1.4.1.498.19.1.4.1.1.6
The number of previous far end intervals for which valid data was collected. The value will be 31 unless the interface was brought on-line within the last 7.75 hours, in which case the value will be the number of complete 15 minute intervals since the interface has been online.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..31  

sc800t3ShelfType 1.3.6.1.4.1.498.19.1.4.1.1.7
Type of shelf the sc800t3 is located in.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER spectracomm(1), twinPack(2)  

sc800t3TwinPackPowerSupply 1.3.6.1.4.1.498.19.1.4.1.1.8
Power supplies currently installed in Twin Pack. When the sc800t3 is located in a Spectracomm shelf none(1) will always be returned.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER none(1), bottomOnly(2), topOnly(3), both(4)  

sc800t3TestAllLeds 1.3.6.1.4.1.498.19.1.4.1.1.9
This variable is used to test the front panel leds and individual segments of the display. A one (1) will turn all leds and display segments on. They will remain on until a two (2) is set or the card is rebooted
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER allLedsON(1), allLedsOFF(2)  

sc800t3NearEndResetStats 1.3.6.1.4.1.498.19.1.4.1.1.10
Supports the action of soft resetting the sc800t3ValidNearEndIntervals object. When this object is set to reset(2), then the unit will reset the sc800t3ValidNearEndIntervals object to zero. The value of norm(1) can not be set by management.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER norm(1), reset(2)  

sc800t3FarEndResetStats 1.3.6.1.4.1.498.19.1.4.1.1.11
Supports the action of soft resetting the sc800t3ValidFarEndIntervals object. When this object is set to reset(2), then the unit will reset the sc800t3ValidFarEndIntervals object to zero. The value of norm(1) can not be set by management.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER norm(1), reset(2)  

sc800t3NearEndStatLastInitial 1.3.6.1.4.1.498.19.1.4.1.1.12
Number of seconds from midnight Dec 31 1969 up until sc800t3ValidNearEndIntervals was last initialized to zero.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2147483647  

sc800t3FarEndStatLastInitial 1.3.6.1.4.1.498.19.1.4.1.1.13
Number of seconds from midnight Dec 31 1969 up until sc800t3ValidFarEndIntervals was last initialized to zero.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2147483647  

sc800t3NoResponse 1.3.6.1.4.1.498.19.1.5.1
OBJECT IDENTIFIER    

sc800t3DiagRxErrAlm 1.3.6.1.4.1.498.19.1.5.2
OBJECT IDENTIFIER    

sc800t3PowerUpAlm 1.3.6.1.4.1.498.19.1.5.3
OBJECT IDENTIFIER    

sc800t3POSTFail 1.3.6.1.4.1.498.19.1.5.4
OBJECT IDENTIFIER    

sc800t3UnsolicitedTest 1.3.6.1.4.1.498.19.1.5.5
OBJECT IDENTIFIER    

sc800t3ConfigChange 1.3.6.1.4.1.498.19.1.5.6
OBJECT IDENTIFIER    

sc800t3TimingLoss 1.3.6.1.4.1.498.19.1.5.7
OBJECT IDENTIFIER    

sc800t3LossOfSignal 1.3.6.1.4.1.498.19.1.5.8
OBJECT IDENTIFIER    

sc800t3OutOfFrame 1.3.6.1.4.1.498.19.1.5.9
OBJECT IDENTIFIER    

sc800t3AIS 1.3.6.1.4.1.498.19.1.5.10
OBJECT IDENTIFIER    

sc800t3DTEReadyLoss 1.3.6.1.4.1.498.19.1.5.11
OBJECT IDENTIFIER    

sc800t3DTETXCLKLoss 1.3.6.1.4.1.498.19.1.5.12
OBJECT IDENTIFIER    

sc800t3RXDNoTrans 1.3.6.1.4.1.498.19.1.5.13
OBJECT IDENTIFIER    

sc800t3TXDNoTrans 1.3.6.1.4.1.498.19.1.5.14
OBJECT IDENTIFIER    

sc800t3RemoteNotResponding 1.3.6.1.4.1.498.19.1.5.15
OBJECT IDENTIFIER    

sc800t3TopPowerSupplyFail 1.3.6.1.4.1.498.19.1.5.16
OBJECT IDENTIFIER    

sc800t3BottomPowerSupplyFail 1.3.6.1.4.1.498.19.1.5.17
OBJECT IDENTIFIER    

sc800t3DTETest 1.3.6.1.4.1.498.19.1.5.18
OBJECT IDENTIFIER    

sc800t3RAI 1.3.6.1.4.1.498.19.1.5.19
OBJECT IDENTIFIER    

sc800t3ES 1.3.6.1.4.1.498.19.1.5.20
OBJECT IDENTIFIER    

sc800t3SES 1.3.6.1.4.1.498.19.1.5.21
OBJECT IDENTIFIER    

sc800t3SAS 1.3.6.1.4.1.498.19.1.5.22
OBJECT IDENTIFIER    

sc800t3UAS 1.3.6.1.4.1.498.19.1.5.23
OBJECT IDENTIFIER    

sc800t3CodeViolations 1.3.6.1.4.1.498.19.1.5.24
OBJECT IDENTIFIER    

sc800t3ESline 1.3.6.1.4.1.498.19.1.5.25
OBJECT IDENTIFIER    

sc800t3AlarmConfigTable 1.3.6.1.4.1.498.19.1.7.1
The sc800t3AlarmConfigTable contains entries that configure alarm reporting. The structure of the table is such that alarm configuration is supported on a unit and interface basis, and then on an alarm type basis within the interface. For simplicity sake alarms, be they unit or interface related, are represented in one table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Sc800t3AlarmConfigEntry

sc800t3AlarmConfigEntry 1.3.6.1.4.1.498.19.1.7.1.1
An entry in the GDC Alarm Configuration table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Sc800t3AlarmConfigEntry  

sc800t3AlarmConfigIndex 1.3.6.1.4.1.498.19.1.7.1.1.1
Integer value which uniquely identifies the SC800T3 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf slot location (01-32) L (byte value) - line number (01) D (byte value) - drop number (00) i (byte value) - interface number (00)
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

sc800t3AlarmConfigIdentifier 1.3.6.1.4.1.498.19.1.7.1.1.2
format: iso.org.dod.internet.private.enterprises.gdc. ds3.sc800t3.sc800t3Alarms.ALM example: 1.3.6.1.4.1.498.19.1.5.ALM where ALM = 1 for sc800t3NoResponse alarm, 2 for sc800t3DiagRxErr alarm, etc., as specified in the Alarm Definitions above.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

sc800t3AlarmCountWindow 1.3.6.1.4.1.498.19.1.7.1.1.3
This variable sets/reads the alarm window. This window is used with the alarm threshold to determine how long the alarm should be active before reporting.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER reportAll(1), last1sec(2), last1min(3), last1hr(4), reportWhen(5)  

sc800t3AlarmCountThreshold 1.3.6.1.4.1.498.19.1.7.1.1.4
This function sets/reads the alarm threshold criteria. This threshold is used along with the the alarm window to determine the number of instances in a given time frame for an alarm to occur before the alarm is considered active.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER thresGT10(1), thresGT100(2), thresGT1000(3), thresGT10000(4), thresGT100000(5), thresGT1000000(6)  

sc800t3CurrentNearEndTable 1.3.6.1.4.1.498.19.1.6.1
Gives the statistic count for the current 15 minute interval.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Sc800t3CurrentNearEndEntry

sc800t3CurrentNearEndEntry 1.3.6.1.4.1.498.19.1.6.1.1
An entry in the sc800t3 CurrentNearEnd table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Sc800t3CurrentNearEndEntry  

sc800t3CurrentNearEndIndex 1.3.6.1.4.1.498.19.1.6.1.1.1
Integer value which uniquely identifies the SC800T3 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf slot location (01-32) L (byte value) - line number (01) D (byte value) - drop number (00) i (byte value) - interface number (00)
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

sc800t3CurrentNearEndStat 1.3.6.1.4.1.498.19.1.6.1.1.2
Returns a bitwise snapshot of the statistics. Octet 1 bit 7 - parity bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - n/a bit 3 - n/a bit 2 - 2^9 Errored Seconds (ES) bit 1 - 2^8 bit 0 - 2^7 Octet 2 bit 7 - parity bit 6 - 2^6 Errored Seconds (ES) bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 3 bit 7 - parity Severely Errored Seconds (SES) bit 6 - Invalid Data Flag bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 4 bit 7 - parity Severely Errored Frames (SAS) bit 6 - Invalid Data Flag bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 5 bit 7 - parity Unavailable Seconds (UAS) bit 6 - Invalid Data Flag bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 6 bit 7 - parity Code Violations (CV) bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - n/a bit 3 - n/a bit 2 - n/a bit 1 - n/a bit 0 - n/a Octet 7 bit 7 - parity bit 6 - 2^13 Code Violations (CV) bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 8 bit 7 - parity bit 6 - 2^6 Code Violations (CV) bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 9 bit 7 - parity bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - n/a bit 3 - n/a bit 2 - 2^9 Errored Seconds Line (ESl) bit 1 - 2^8 bit 0 - 2^7 Octet 10 bit 7 - parity bit 6 - 2^6 Errored Seconds Line (ESl) bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 11 bit 7 - parity bit 6 - 2^6 Percent Complete bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(11)  

sc800t3CurrentFarEndTable 1.3.6.1.4.1.498.19.1.6.3
Gives the statistic count for the current 15 minute interval.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Sc800t3CurrentFarEndEntry

sc800t3CurrentFarEndEntry 1.3.6.1.4.1.498.19.1.6.3.1
An entry in the sc800t3 CurrentFarEnd table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Sc800t3CurrentFarEndEntry  

sc800t3CurrentFarEndIndex 1.3.6.1.4.1.498.19.1.6.3.1.1
Integer value which uniquely identifies the SC800T3 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf slot location (01-32) L (byte value) - line number (01) D (byte value) - drop number (00) i (byte value) - interface number (00)
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

sc800t3CurrentFarEndStat 1.3.6.1.4.1.498.19.1.6.3.1.2
Returns a bitwise snapshot of the statistics. Octet 1 bit 7 - parity bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - n/a bit 3 - n/a bit 2 - 2^9 Errored Seconds (ES) bit 1 - 2^8 bit 0 - 2^7 Octet 2 bit 7 - parity bit 6 - 2^6 Errored Seconds (ES) bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 3 bit 7 - parity Severely Errored Seconds (SES) bit 6 - Invalid Data Flag bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 4 bit 7 - parity Severely Errored Frames (SAS) bit 6 - Invalid Data Flag bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 5 bit 7 - parity Unavailable Seconds (UAS) bit 6 - Invalid Data Flag bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 6 bit 7 - parity Code Violations (CV) bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - n/a bit 3 - n/a bit 2 - n/a bit 1 - n/a bit 0 - n/a Octet 7 bit 7 - parity bit 6 - 2^13 Code Violations (CV) bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 8 bit 7 - parity bit 6 - 2^6 Code Violations (CV) bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 9 bit 7 - parity bit 6 - 2^6 Percent Complete bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(9)  

sc800t3CurrentDayNearEndTable 1.3.6.1.4.1.498.19.1.6.4
Gives totals for the current day of all the near end statistics.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Sc800t3CurrentDayNearEndEntry

sc800t3CurrentDayNearEndEntry 1.3.6.1.4.1.498.19.1.6.4.1
An entry in the sc800t3 CurrentDayNearEndTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Sc800t3CurrentDayNearEndEntry  

sc800t3CurrentDayNearEndIndex 1.3.6.1.4.1.498.19.1.6.4.1.1
Integer value which uniquely identifies the SC800T3 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf slot location (01-32) L (byte value) - line number (01) D (byte value) - drop number (00) i (byte value) - interface number (00)
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

sc800t3CurrentDayNearEndStat 1.3.6.1.4.1.498.19.1.6.4.1.2
Returns a bitwise snapshot of the statistics. Octet 1 bit 7 - parity bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - n/a bit 3 - n/a bit 2 - n/a bit 1 - 2^15 Errored Seconds (ES) bit 0 - 2^14 Octet 2 bit 7 - parity bit 6 - 2^13 Errored Seconds (ES) bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 3 bit 7 - parity bit 6 - 2^6 Errored Seconds (ES) bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 4 bit 7 - parity Severely Errored Seconds (SES) bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 5 bit 7 - parity bit 6 - 2^6 Severely Errored Seconds (SES) bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 6 bit 7 - parity Severely Errored Frame (SAS) bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 7 bit 7 - parity bit 6 - 2^6 Severely Errored Frame (SAS) bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 8 bit 7 - parity Unavailable Seconds (UAS) bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 9 bit 7 - parity bit 6 - 2^6 Unavailable Seconds (UAS) bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 10 bit 7 - parity Code Violations (CV) bit 6 - Invalid Data Flag bit 5 - 2^19 bit 4 - 2^18 bit 3 - 2^17 bit 2 - 2^16 bit 1 - 2^15 bit 0 - 2^14 Octet 11 bit 7 - parity bit 6 - 2^13 Code Violations (CV) bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 12 bit 7 - parity bit 6 - 2^6 Code Violations (CV) bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 13 bit 7 - parity bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - n/a bit 3 - n/a bit 2 - n/a bit 1 - 2^15 Errored Seconds Line (ESl) bit 0 - 2^14 Octet 14 bit 7 - parity bit 6 - 2^13 Errored Seconds Line (ESl) bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 15 bit 7 - parity bit 6 - 2^6 Errored Seconds Line (ESl) bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 16 bit 7 - parity bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - n/a bit 3 - n/a bit 2 - n/a bit 1 - 2^15 FC-P Path Failure Events bit 0 - 2^14 Octet 17 bit 7 - parity bit 6 - 2^13 FC-P Path Failure Events bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 18 bit 7 - parity bit 6 - 2^6 FC-P Path Failure Events bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(18)  

sc800t3CurrentDayFarEndTable 1.3.6.1.4.1.498.19.1.6.6
Gives totals for the current day of all the Far End statistics.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Sc800t3CurrentDayFarEndEntry

sc800t3CurrentDayFarEndEntry 1.3.6.1.4.1.498.19.1.6.6.1
An entry in the sc800t3CurrentDayFarEndTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Sc800t3CurrentDayFarEndEntry  

sc800t3CurrentDayFarEndIndex 1.3.6.1.4.1.498.19.1.6.6.1.1
Integer value which uniquely identifies the SC800T3 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf slot location (01-32) L (byte value) - line number (01) D (byte value) - drop number (00) i (byte value) - interface number (00)
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

sc800t3CurrentDayFarEndStat 1.3.6.1.4.1.498.19.1.6.6.1.2
Returns a bitwise snapshot of the statistics. Octet 1 bit 7 - parity bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - n/a bit 3 - n/a bit 2 - n/a bit 1 - 2^15 Errored Seconds (ES) bit 0 - 2^14 Octet 2 bit 7 - parity bit 6 - 2^13 Errored Seconds (ES) bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 3 bit 7 - parity bit 6 - 2^6 Errored Seconds (ES) bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 4 bit 7 - parity Severely Errored Seconds (SES) bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 5 bit 7 - parity bit 6 - 2^6 Severely Errored Seconds (SES) bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 6 bit 7 - parity Severely Errored Frame (SAS) bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 7 bit 7 - parity bit 6 - 2^6 Severely Errored Frame (SAS) bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 8 bit 7 - parity Unavailable Seconds (UAS) bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 9 bit 7 - parity bit 6 - 2^6 Unavailable Seconds (UAS) bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 10 bit 7 - parity Code Violations (CV) bit 6 - Invalid Data Flag bit 5 - 2^19 bit 4 - 2^18 bit 3 - 2^17 bit 2 - 2^16 bit 1 - 2^15 bit 0 - 2^14 Octet 11 bit 7 - parity bit 6 - 2^13 Code Violations (CV) bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 12 bit 7 - parity bit 6 - 2^6 Code Violations (CV) bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 13 bit 7 - parity FCCP-PFE Path Failure Events bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - n/a bit 3 - n/a bit 2 - n/a bit 1 - 2^15 bit 0 - 2^14 Octet 14 bit 7 - parity bit 6 - 2^13 FCCP-PFE Path Failure Events bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 15 bit 7 - parity bit 6 - 2^6 FCCP-PFE Path Failure Events bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(15)  

sc800t3PreviousDayNearEndTable 1.3.6.1.4.1.498.19.1.6.2
Gives totals for the previous day of all the near end statistics.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Sc800t3PreviousDayNearEndEntry

sc800t3PreviousDayNearEndEntry 1.3.6.1.4.1.498.19.1.6.2.1
An entry in the sc800t3 PreviousDayNearEndTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Sc800t3PreviousDayNearEndEntry  

sc800t3PreviousDayNearEndIndex 1.3.6.1.4.1.498.19.1.6.2.1.1
Integer value which uniquely identifies the SC800T3 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf slot location (01-32) L (byte value) - line number (01) D (byte value) - drop number (00) i (byte value) - interface number (00)
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

sc800t3PreviousDayNearEndStat 1.3.6.1.4.1.498.19.1.6.2.1.2
Returns a bitwise snapshot of the statistics. Octet 1 bit 7 - parity bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - n/a bit 3 - n/a bit 2 - n/a bit 1 - 2^15 Errored Seconds (ES) bit 0 - 2^14 Octet 2 bit 7 - parity bit 6 - 2^13 Errored Seconds (ES) bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 3 bit 7 - parity bit 6 - 2^6 Errored Seconds (ES) bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 4 bit 7 - parity Severely Errored Seconds (SES) bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 5 bit 7 - parity bit 6 - 2^6 Severely Errored Seconds (SES) bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 6 bit 7 - parity Severely Errored Frame (SAS) bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 7 bit 7 - parity bit 6 - 2^6 Severely Errored Frame (SAS) bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 8 bit 7 - parity Unavailable Seconds (UAS) bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 9 bit 7 - parity bit 6 - 2^6 Unavailable Seconds (UAS) bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 10 bit 7 - parity Code Violations (CV) bit 6 - Invalid Data Flag bit 5 - 2^19 bit 4 - 2^18 bit 3 - 2^17 bit 2 - 2^16 bit 1 - 2^15 bit 0 - 2^14 Octet 11 bit 7 - parity bit 6 - 2^13 Code Violations (CV) bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 12 bit 7 - parity bit 6 - 2^6 Code Violations (CV) bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 13 bit 7 - parity bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - n/a bit 3 - n/a bit 2 - n/a bit 1 - 2^15 Errored Seconds Line (ESl) bit 0 - 2^14 Octet 14 bit 7 - parity bit 6 - 2^13 Errored Seconds Line (ESl) bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 15 bit 7 - parity bit 6 - 2^6 Errored Seconds Line (ESl) bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 16 bit 7 - parity bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - n/a bit 3 - n/a bit 2 - n/a bit 1 - 2^15 FC-P Path Failure Events bit 0 - 2^14 Octet 17 bit 7 - parity bit 6 - 2^13 FC-P Path Failure Events bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 18 bit 7 - parity bit 6 - 2^6 FC-P Path Failure Events bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(18)  

sc800t3PreviousDayFarEndTable 1.3.6.1.4.1.498.19.1.6.5
Gives totals for the previous day of all the Far End statistics.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Sc800t3PreviousDayFarEndEntry

sc800t3PreviousDayFarEndEntry 1.3.6.1.4.1.498.19.1.6.5.1
An entry in the sc800t3PreviousDayFarEndTable.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Sc800t3PreviousDayFarEndEntry  

sc800t3PreviousDayFarEndIndex 1.3.6.1.4.1.498.19.1.6.5.1.1
Integer value which uniquely identifies the SC800T3 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf slot location (01-32) L (byte value) - line number (01) D (byte value) - drop number (00) i (byte value) - interface number (00)
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

sc800t3PreviousDayFarEndStat 1.3.6.1.4.1.498.19.1.6.5.1.2
Returns a bitwise snapshot of the statistics. Octet 1 bit 7 - parity bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - n/a bit 3 - n/a bit 2 - n/a bit 1 - 2^15 Errored Seconds (ES) bit 0 - 2^14 Octet 2 bit 7 - parity bit 6 - 2^13 Errored Seconds (ES) bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 3 bit 7 - parity bit 6 - 2^6 Errored Seconds (ES) bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 4 bit 7 - parity Severely Errored Seconds (SES) bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 5 bit 7 - parity bit 6 - 2^6 Severely Errored Seconds (SES) bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 6 bit 7 - parity Severely Errored Frame (SAS) bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 7 bit 7 - parity bit 6 - 2^6 Severely Errored Frame (SAS) bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 8 bit 7 - parity Unavailable Seconds (UAS) bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 9 bit 7 - parity bit 6 - 2^6 Unavailable Seconds (UAS) bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 10 bit 7 - parity Code Violations (CV) bit 6 - Invalid Data Flag bit 5 - 2^19 bit 4 - 2^18 bit 3 - 2^17 bit 2 - 2^16 bit 1 - 2^15 bit 0 - 2^14 Octet 11 bit 7 - parity bit 6 - 2^13 Code Violations (CV) bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 12 bit 7 - parity bit 6 - 2^6 Code Violations (CV) bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 13 bit 7 - parity FCCP-PFE Path Failure Events bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - n/a bit 3 - n/a bit 2 - n/a bit 1 - 2^15 bit 0 - 2^14 Octet 14 bit 7 - parity bit 6 - 2^13 FCCP-PFE Path Failure Events bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 15 bit 7 - parity bit 6 - 2^6 FCCP-PFE Path Failure Events bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(15)  

sc800t3NearEndIntervalTable 1.3.6.1.4.1.498.19.1.6.7
The sc800t3 Near End Interval table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Sc800t3NearEndIntervalEntry

sc800t3NearEndIntervalEntry 1.3.6.1.4.1.498.19.1.6.7.1
An entry in the Interval table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Sc800t3NearEndIntervalEntry  

sc800t3NearEndIntervalIndex 1.3.6.1.4.1.498.19.1.6.7.1.1
Integer value which uniquely identifies the SC800T3 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf slot location (01-32) L (byte value) - line number (01) D (byte value) - drop number (00) i (byte value) - interface number (00)
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

sc800t3NearEndIntervalNumber 1.3.6.1.4.1.498.19.1.6.7.1.2
A number between 1 and 31, where 1 is the most recently completed minute interval and 31 is the least recently completed 15 minutes interval (assuming that all 31 intervals are valid).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..31  

sc800t3NearEndIntervalStats 1.3.6.1.4.1.498.19.1.6.7.1.3
Returns a bitwise snapshot of the statistics. Octet 1 bit 7 - parity bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - n/a bit 3 - n/a bit 2 - 2^9 Errored Seconds (ES) bit 1 - 2^8 bit 0 - 2^7 Octet 2 bit 7 - parity bit 6 - 2^6 Errored Seconds (ES) bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 3 bit 7 - parity Severely Errored Seconds (SES) bit 6 - Invalid Data Flag bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 4 bit 7 - parity Severely Errored Frames (SAS) bit 6 - Invalid Data Flag bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 5 bit 7 - parity Unavailable Seconds (UAS) bit 6 - Invalid Data Flag bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 6 bit 7 - parity Code Violations (CV) bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - n/a bit 3 - n/a bit 2 - n/a bit 1 - n/a bit 0 - n/a Octet 7 bit 7 - parity bit 6 - 2^13 Code Violations (CV) bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 8 bit 7 - parity bit 6 - 2^6 Code Violations (CV) bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 9 bit 7 - parity bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - n/a bit 3 - n/a bit 2 - 2^9 Errored Seconds Line (ESl) bit 1 - 2^8 bit 0 - 2^7 Octet 10 bit 7 - parity bit 6 - 2^6 Errored Seconds Line (ESl) bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 11 bit 7 - parity bit 6 - n/a Interval (1-31) bit 5 - n/a bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(11)  

sc800t3FarEndIntervalTable 1.3.6.1.4.1.498.19.1.6.9
The sc800t3 Far End Interval table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Sc800t3FarEndIntervalEntry

sc800t3FarEndIntervalEntry 1.3.6.1.4.1.498.19.1.6.9.1
An entry in the Interval table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Sc800t3FarEndIntervalEntry  

sc800t3FarEndIntervalIndex 1.3.6.1.4.1.498.19.1.6.9.1.1
Integer value which uniquely identifies the SC800T3 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf slot location (01-32) L (byte value) - line number (01) D (byte value) - drop number (00) i (byte value) - interface number (00)
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

sc800t3FarEndIntervalNumber 1.3.6.1.4.1.498.19.1.6.9.1.2
A number between 1 and 31, where 1 is the most recently completed minute interval and 31 is the least recently completed 15 minutes interval (assuming that all 31 intervals are valid).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..31  

sc800t3FarEndIntervalStats 1.3.6.1.4.1.498.19.1.6.9.1.3
Returns a bitwise snapshot of the statistics. Octet 1 bit 7 - parity bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - n/a bit 3 - n/a bit 2 - 2^9 Errored Seconds (ES) bit 1 - 2^8 bit 0 - 2^7 Octet 2 bit 7 - parity bit 6 - 2^6 Errored Seconds (ES) bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 3 bit 7 - parity Severely Errored Seconds (SES) bit 6 - Invalid Data Flag bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 4 bit 7 - parity Severely Errored Frames (SAS) bit 6 - Invalid Data Flag bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 5 bit 7 - parity Unavailable Seconds (UAS) bit 6 - Invalid Data Flag bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 6 bit 7 - parity Code Violations (CV) bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - n/a bit 3 - n/a bit 2 - n/a bit 1 - n/a bit 0 - n/a Octet 7 bit 7 - parity bit 6 - 2^13 Code Violations (CV) bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 8 bit 7 - parity bit 6 - 2^6 Code Violations (CV) bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 9 bit 7 - parity bit 6 - n/a Interval (1-31) bit 5 - n/a bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(9)  

sc800t3PreviousNearEndTable 1.3.6.1.4.1.498.19.1.6.10
Gives the statistic count for the previous 15 minute interval.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Sc800t3PreviousNearEndEntry

sc800t3PreviousNearEndEntry 1.3.6.1.4.1.498.19.1.6.10.1
An entry in the sc800t3 PreviousNearEnd table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Sc800t3PreviousNearEndEntry  

sc800t3PreviousNearEndIndex 1.3.6.1.4.1.498.19.1.6.10.1.1
Integer value which uniquely identifies the SC800T3 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf slot location (01-32) L (byte value) - line number (01) D (byte value) - drop number (00) i (byte value) - interface number (00)
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

sc800t3PreviousNearEndStat 1.3.6.1.4.1.498.19.1.6.10.1.2
Returns a bitwise snapshot of the statistics. Octet 1 bit 7 - f/u bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - n/a bit 3 - n/a bit 2 - 2^9 Errored Seconds (ES) bit 1 - 2^8 bit 0 - 2^7 Octet 2 bit 7 - f/u bit 6 - 2^6 Errored Seconds (ES) bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 3 bit 7 - f/u Severely Errored Seconds (SES) bit 6 - Invalid Data Flag bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 4 bit 7 - f/u Severely Errored Frames (SAS) bit 6 - Invalid Data Flag bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 5 bit 7 - f/u Unavailable Seconds (UAS) bit 6 - Invalid Data Flag bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 6 bit 7 - f/u Code Violations (CV) bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - n/a bit 3 - n/a bit 2 - n/a bit 1 - n/a bit 0 - n/a Octet 7 bit 7 - f/u bit 6 - 2^13 Code Violations (CV) bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 8 bit 7 - f/u bit 6 - 2^6 Code Violations (CV) bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 9 bit 7 - fu bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - n/a bit 3 - n/a bit 2 - 2^9 Errored Seconds Line (ESl) bit 1 - 2^8 bit 0 - 2^7 Octet 10 bit 7 - f/u bit 6 - 2^6 Errored Seconds Line (ESl) bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 11 bit 7 - f/u bit 6 - 2^6 Percent Complete bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(11)  

sc800t3PreviousFarEndTable 1.3.6.1.4.1.498.19.1.6.11
Gives the statistic count for the previous 15 minute interval.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Sc800t3PreviousFarEndEntry

sc800t3PreviousFarEndEntry 1.3.6.1.4.1.498.19.1.6.11.1
An entry in the sc800t3 PreviousFarEnd table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Sc800t3PreviousFarEndEntry  

sc800t3PreviousFarEndIndex 1.3.6.1.4.1.498.19.1.6.11.1.1
Integer value which uniquely identifies the SC800T3 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf slot location (01-32) L (byte value) - line number (01) D (byte value) - drop number (00) i (byte value) - interface number (00)
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

sc800t3PreviousFarEndStat 1.3.6.1.4.1.498.19.1.6.11.1.2
Returns a bitwise snapshot of the statistics. Octet 1 bit 7 - f/u bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - n/a bit 3 - n/a bit 2 - 2^9 Errored Seconds (ES) bit 1 - 2^8 bit 0 - 2^7 Octet 2 bit 7 - f/u bit 6 - 2^6 Errored Seconds (ES) bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 3 bit 7 - f/u Severely Errored Seconds (SES) bit 6 - Invalid Data Flag bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 4 bit 7 - f/u Severely Errored Frames (SAS) bit 6 - Invalid Data Flag bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 5 bit 7 - f/u Unavailable Seconds (UAS) bit 6 - Invalid Data Flag bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0 Octet 6 bit 7 - f/u Code Violations (CV) bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - n/a bit 3 - n/a bit 2 - n/a bit 1 - n/a bit 0 - n/a Octet 7 bit 7 - f/u bit 6 - 2^13 Code Violations (CV) bit 5 - 2^12 bit 4 - 2^11 bit 3 - 2^10 bit 2 - 2^9 bit 1 - 2^8 bit 0 - 2^7 Octet 8 bit 7 - f/u bit 6 - 2^6 Code Violations (CV) bit 5 - 2^5 bit 4 - 2^4 bit 3 - 2^3 bit 2 - 2^2 bit 1 - 2^1 bit 0 - 2^0
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

sc800t3LocalAlarmConfigTable 1.3.6.1.4.1.498.19.1.8.1
The sc800t3LocalAlarmConfigTable contains entries that configure alarm reporting. The structure of the table is such that alarm configuration is supported on a unit and interface basis, and then on an alarm type basis within the interface. For simplicity sake alarms, be they unit or interface related, are represented in one table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Sc800t3LocalAlarmConfigEntry

sc800t3LocalAlarmConfigEntry 1.3.6.1.4.1.498.19.1.8.1.1
An entry in the GDC Local Alarm Configuration table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Sc800t3LocalAlarmConfigEntry  

sc800t3LocalAlarmConfigIndex 1.3.6.1.4.1.498.19.1.8.1.1.1
The index value which uniquely identifies the interface to which this entry is applicable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  SCinstance  

sc800t3OOF 1.3.6.1.4.1.498.19.1.8.1.1.2
Disables or enables the alarm on the Major buss or Minor buss.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabledMajor(2), enabledMinor(3)  

sc800t3AISLOCAL 1.3.6.1.4.1.498.19.1.8.1.1.3
Disables or enables the alarm on the Major buss or Minor buss.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabledMajor(2), enabledMinor(3)  

sc800t3TIMLOS 1.3.6.1.4.1.498.19.1.8.1.1.4
Disables or enables the alarm on the Major buss or Minor buss.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabledMajor(2), enabledMinor(3)  

sc800t3TXDLOS 1.3.6.1.4.1.498.19.1.8.1.1.5
Disables or enables the alarm on the Major buss or Minor buss.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabledMajor(2), enabledMinor(3)  

sc800t3RXDLOS 1.3.6.1.4.1.498.19.1.8.1.1.6
Disables or enables the alarm on the Major buss or Minor buss.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabledMajor(2), enabledMinor(3)  

sc800t3LOS 1.3.6.1.4.1.498.19.1.8.1.1.7
Disables or enables the alarm on the Major buss or Minor buss.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabledMajor(2), enabledMinor(3)  

sc800t3TPSFAIL 1.3.6.1.4.1.498.19.1.8.1.1.8
Disables or enables the alarm on the Major buss or Minor buss.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabledMajor(2), enabledMinor(3)  

sc800t3BPSFAIL 1.3.6.1.4.1.498.19.1.8.1.1.9
Disables or enables the alarm on the Major buss or Minor buss.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabledMajor(2), enabledMinor(3)  

sc800t3DTECLKLOS 1.3.6.1.4.1.498.19.1.8.1.1.10
Disables or enables the alarm on the Major buss or Minor buss.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabledMajor(2), enabledMinor(3)  

sc800t3DTERDYLOS 1.3.6.1.4.1.498.19.1.8.1.1.11
Disables or enables the alarm on the Major buss or Minor buss.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabledMajor(2), enabledMinor(3)  

sc800t3RAILOCAL 1.3.6.1.4.1.498.19.1.8.1.1.12
Disables or enables the alarm on the Major buss or Minor buss.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabledMajor(2), enabledMinor(3)  

sc800t3THRESHESL 1.3.6.1.4.1.498.19.1.8.1.1.13
Disables or enables the alarm on the Major buss or Minor buss.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabledMajor(2), enabledMinor(3)  

sc800t3THRESHES 1.3.6.1.4.1.498.19.1.8.1.1.14
Disables or enables the alarm on the Major buss or Minor buss.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabledMajor(2), enabledMinor(3)  

sc800t3THRESHSES 1.3.6.1.4.1.498.19.1.8.1.1.15
Disables or enables the alarm on the Major buss or Minor buss.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabledMajor(2), enabledMinor(3)  

sc800t3THRESHSAS 1.3.6.1.4.1.498.19.1.8.1.1.16
Disables or enables the alarm on the Major buss or Minor buss.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabledMajor(2), enabledMinor(3)  

sc800t3THRESHUAS 1.3.6.1.4.1.498.19.1.8.1.1.17
Disables or enables the alarm on the Major buss or Minor buss.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabledMajor(2), enabledMinor(3)  

sc800t3THRESHCV 1.3.6.1.4.1.498.19.1.8.1.1.18
Disables or enables the alarm on the Major buss or Minor buss.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabledMajor(2), enabledMinor(3)