Fore-frs-MIB

File: Fore-frs-MIB.mib (37357 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC Fore-Common-MIB
IF-MIB

Imported symbols

Integer32 TimeTicks Counter32
Gauge32 OBJECT-TYPE MODULE-IDENTITY
DisplayString frameInternetworking InterfaceIndex

Defined Types

FrextDlcmiEntry  
SEQUENCE    
  frextDlcmiServiceIfIndex InterfaceIndex
  frextDlcmiProfileLmiIndex Integer32
  frextDlcmiProfileServiceIndex Integer32
  frextDlcmiStatsMonitor INTEGER
  frextDlcmiStatsEnabledTimeStamp TimeTicks
  frextDlcmiLmiDlci Integer32
  frextDlcmiLmiFlowControl INTEGER
  frextDlcmiRAControl INTEGER
  frextDlcmiLmiBandwidthControl INTEGER
  frextDlcmiRxAbortedFrames Counter32
  frextDlcmiRcvCrcErrors Counter32
  frextDlcmiRcvShortFrames Counter32
  frextDlcmiRcvLongFrames Counter32
  frextDlcmiRcvInvalidDLCI Counter32
  frextDlcmiRcvUnknownErrs Counter32
  frextDlcmiLmiTxStatusResponses Counter32
  frextDlcmiLmiTxFullStatusResponses Counter32
  frextDlcmiLmiTxStatusEnquiries Counter32
  frextDlcmiLmiTxFullStatusEnquiries Counter32
  frextDlcmiLmiRxStatusResponses Counter32
  frextDlcmiLmiRxFullStatusResponses Counter32
  frextDlcmiLmiRxStatusEnquiries Counter32
  frextDlcmiLmiRxFullStatusEnquiries Counter32
  frextDlcmiLmiUnknownMessagesRcvd Counter32
  frextDlcmiLmiStatusLostSequences Counter32
  frextDlcmiLmiStatusEnqLostSequences Counter32
  frextDlcmiLmiMissingStatEnquiries Counter32
  frextDlcmiLmiUnexpectedPVCStatMsg Counter32
  frextDlcmiLmiUnexpectedDLCI Counter32
  frextDlcmiLmiStatEnqRatePlus Counter32
  frextDlcmiLmiInvInfoFrame Counter32
  frextDlcmiLmiInvFrameHdr Counter32
  frextDlcmiLmiNoIERepType Counter32
  frextDlcmiLmiNoIEKeepAlive Counter32
  frextDlcmiLmiMissingResponses Counter32
  frextDlcmiLmiUnsuppIERcvd Counter32
  frextDlcmiPvccs Gauge32

FrextCircuitEntry  
SEQUENCE    
  frextCircuitServiceIfIndex InterfaceIndex
  frextCircuitDlci Integer32
  frextCircuitName DisplayString
  frextCircuitProfileFrRateIndex Integer32
  frextCircuitREMonitor INTEGER
  frextCircuitRateFallbacks Counter32
  frextCircuitRateFallforwards Counter32
  frextCircuitEgFramesDroppedQueueFull Counter32
  frextCircuitNormalSentFrames Counter32
  frextCircuitNormalSentOctets Counter32
  frextCircuitExcessSentOctets Counter32
  frextCircuitHeldBuffers Counter32
  frextCircuitOctetsOnQueue Counter32
  frextCircuitBuffersOnQueue Counter32
  frextCircuitRxMonNormalFrames Counter32
  frextCircuitRxMonNormalOctets Counter32
  frextCircuitRxMonExcessOctets Counter32
  frextCircuitRxMonDroppedOctets Counter32
  frextCircuitRxMonDroppedDEFrames Counter32
  frextCircuitRxMonDroppedDEOctets Counter32
  frextCircuitRxMonDEOctets Counter32
  frextCircuitRxMonSetDEFrames Counter32
  frextCircuitRxMonSetDEOctets Counter32
  frextCircuitRecvdBECNS Counter32
  frextCircuitRecvdFECNS Counter32

FrsOamF5Entry  
SEQUENCE    
  frsOamF5AtmIf Integer32
  frsOamF5AtmVpi Integer32
  frsOamF5AtmVci Integer32
  frsOamF5AISRxCounter Counter32
  frsOamF5AISTxCounter Counter32
  frsOamF5RDIRxCounter Counter32
  frsOamF5RDITxCounter Counter32

Defined Values

foreFrameRelayModule 1.3.6.1.4.1.326.1.16.1
This MIB is considered as being required in addition to the standard mibs RFC1604 and RFC1315. It provides configuration and statistics information at frame relay service and connection level.
MODULE-IDENTITY    

frextDlcmiTable 1.3.6.1.4.1.326.1.16.1.1
The Parameters for the Data Link Connection Management Interface corresponding to any given ifEntry. These parameters are logical extensions to those in contained within the object frDlcmiTable in RFC1315.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FrextDlcmiEntry

frextDlcmiEntry 1.3.6.1.4.1.326.1.16.1.1.1
The Parameters for the Data Link Connection Management Interface.
Status: current Access: not-accessible
OBJECT-TYPE    
  FrextDlcmiEntry  

frextDlcmiServiceIfIndex 1.3.6.1.4.1.326.1.16.1.1.1.1
The Service/FR-UNI identifier ifIndex value of the corresponding ifEntry.
Status: current Access: read-only
OBJECT-TYPE    
  InterfaceIndex  

frextDlcmiProfileLmiIndex 1.3.6.1.4.1.326.1.16.1.1.1.2
Index for the LMI profile for this FR service.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

frextDlcmiProfileServiceIndex 1.3.6.1.4.1.326.1.16.1.1.1.3
Index of the Service profile for this FR service.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

frextDlcmiStatsMonitor 1.3.6.1.4.1.326.1.16.1.1.1.4
This object specifies whether statistics are to be counted at a service level, this includes service and connection statistics. When the state changes from enabled to disabled all the related statistics will be frozen at their current value. When the state changes from disabled to enabled then all related statistics will be reset (zeroised). Note that this Monitor is overriden by the netmod level nmFramStatsMonitor. Refer to fore-fram.mib for more details.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

frextDlcmiStatsEnabledTimeStamp 1.3.6.1.4.1.326.1.16.1.1.1.5
This object reflects the point in time, with reference to sysUpTime, either when frextDlcmiStatsMonitor is set to enabled or when nmFramStatsMonitor is set to enabled. The time will reflect the last StatsMonitor to be enabled. The timestamp provides a starting timestamp for the current statistics that are being counted.
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

frextDlcmiLmiDlci 1.3.6.1.4.1.326.1.16.1.1.1.6
the dlci upon which LMI traffic will be broadcast. If Q933-AnnexA=0, otherwise STRATACOM=1023.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frextDlcmiLmiFlowControl 1.3.6.1.4.1.326.1.16.1.1.1.7
Specifies whether STRATACOM LMI based (R-bit) notification performs flow control for the Circuits on this interface.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

frextDlcmiRAControl 1.3.6.1.4.1.326.1.16.1.1.1.8
Specifies whether Rate Adaptation-RA performs flow control for the Circuits on this interface.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

frextDlcmiLmiBandwidthControl 1.3.6.1.4.1.326.1.16.1.1.1.9
Specifies whether STRATACOM LMI based CIR notification affects the CIR flow control parameters for the connections on this interface.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

frextDlcmiRxAbortedFrames 1.3.6.1.4.1.326.1.16.1.1.1.10
The number of aborted frames received on this Frame Relay logical interface.A frame is considered aborted after receiving 7 or more continuous ones.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

frextDlcmiRcvCrcErrors 1.3.6.1.4.1.326.1.16.1.1.1.11
Specifies the number of frames receive with CRC errors on this interface.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

frextDlcmiRcvShortFrames 1.3.6.1.4.1.326.1.16.1.1.1.12
The number of frames containing less than 5 octets received on this interface.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

frextDlcmiRcvLongFrames 1.3.6.1.4.1.326.1.16.1.1.1.13
The number of frames containing greater than 8191 octets received on this interface.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

frextDlcmiRcvInvalidDLCI 1.3.6.1.4.1.326.1.16.1.1.1.14
The number of frames with an invalid DLCI received on this interface.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

frextDlcmiRcvUnknownErrs 1.3.6.1.4.1.326.1.16.1.1.1.15
The number of frames with other errors received on this interface.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

frextDlcmiLmiTxStatusResponses 1.3.6.1.4.1.326.1.16.1.1.1.16
Number of STATUS messages transmited on this interface.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

frextDlcmiLmiTxFullStatusResponses 1.3.6.1.4.1.326.1.16.1.1.1.17
Number of STATUS messages with full status IE transmited on this interface.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

frextDlcmiLmiTxStatusEnquiries 1.3.6.1.4.1.326.1.16.1.1.1.18
Number of STATUS ENQUIRY messages transmited on this interface.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

frextDlcmiLmiTxFullStatusEnquiries 1.3.6.1.4.1.326.1.16.1.1.1.19
Number of STATUS ENQUIRY messages with full status IE transmited on this interface.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

frextDlcmiLmiRxStatusResponses 1.3.6.1.4.1.326.1.16.1.1.1.20
Number of STATUS messages received on this interface.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

frextDlcmiLmiRxFullStatusResponses 1.3.6.1.4.1.326.1.16.1.1.1.21
Number of STATUS messages with full status IE received on this interface.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

frextDlcmiLmiRxStatusEnquiries 1.3.6.1.4.1.326.1.16.1.1.1.22
Number of STATUS messages received on this interface.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

frextDlcmiLmiRxFullStatusEnquiries 1.3.6.1.4.1.326.1.16.1.1.1.23
Number of STATUS ENQUIRY messages with full status IE (Information Element) receive on this interface.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

frextDlcmiLmiUnknownMessagesRcvd 1.3.6.1.4.1.326.1.16.1.1.1.24
Number of Unknown LMI messages received on this interface.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

frextDlcmiLmiStatusLostSequences 1.3.6.1.4.1.326.1.16.1.1.1.25
The total number of times a loss of sequencing in received STATUS messages was detected on this interface.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

frextDlcmiLmiStatusEnqLostSequences 1.3.6.1.4.1.326.1.16.1.1.1.26
The total number of times a loss of sequencing in received STATUS ENQUIRY messages was detected on this interface.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

frextDlcmiLmiMissingStatEnquiries 1.3.6.1.4.1.326.1.16.1.1.1.27
The number of times an expected STATUS ENQUIRY message was not received within the expected time on this interface.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

frextDlcmiLmiUnexpectedPVCStatMsg 1.3.6.1.4.1.326.1.16.1.1.1.28
The number of LMI messages that were received with unexpected PVC STATUS IE on this interface.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

frextDlcmiLmiUnexpectedDLCI 1.3.6.1.4.1.326.1.16.1.1.1.29
The number of STATUS messages received with unconfigured DLCI
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

frextDlcmiLmiStatEnqRatePlus 1.3.6.1.4.1.326.1.16.1.1.1.30
The number of times the STATUS ENQUIRY message was received more frequently than expected. For STRATACOM only
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

frextDlcmiLmiInvInfoFrame 1.3.6.1.4.1.326.1.16.1.1.1.31
The number of times an LMI message was received with information type not equal to unnumbered information type.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

frextDlcmiLmiInvFrameHdr 1.3.6.1.4.1.326.1.16.1.1.1.32
The number of LMI frames received with error in the header bits.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

frextDlcmiLmiNoIERepType 1.3.6.1.4.1.326.1.16.1.1.1.33
The number of times an LMI frame was received with missing Report Type IE
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

frextDlcmiLmiNoIEKeepAlive 1.3.6.1.4.1.326.1.16.1.1.1.34
The number of times an LMI frame was received with missing Link Integrity Verification IE.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

frextDlcmiLmiMissingResponses 1.3.6.1.4.1.326.1.16.1.1.1.35
The total number of times a timeout occurred without receiving a response to an LMI request by this interface.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

frextDlcmiLmiUnsuppIERcvd 1.3.6.1.4.1.326.1.16.1.1.1.36
The number of LMI messages received with unknown Information Element.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

frextDlcmiPvccs 1.3.6.1.4.1.326.1.16.1.1.1.37
The number of permanent VCCs established on this Frame Relay logical interface
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

frextCircuitTable 1.3.6.1.4.1.326.1.16.1.2
A table containing information about specific Data Link Connection Identifiers and corresponding connections.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FrextCircuitEntry

frextCircuitEntry 1.3.6.1.4.1.326.1.16.1.2.1
The information regarding a single Data Link Connection Identifier.
Status: current Access: not-accessible
OBJECT-TYPE    
  FrextCircuitEntry  

frextCircuitServiceIfIndex 1.3.6.1.4.1.326.1.16.1.2.1.1
IfIndex of the Frame Relay Interface,UNI, to which data received from ATM is forwarded.The index generated by the agent for Frame Relay service identification. This index is volatile over power down
Status: current Access: read-only
OBJECT-TYPE    
  InterfaceIndex  

frextCircuitDlci 1.3.6.1.4.1.326.1.16.1.2.1.2
The connections' Frame Relay DLCI.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frextCircuitName 1.3.6.1.4.1.326.1.16.1.2.1.3
The user-defined name for the connection.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

frextCircuitProfileFrRateIndex 1.3.6.1.4.1.326.1.16.1.2.1.4
Index of the ProfileFRRateTable (rate enforcement/rate adaptation configuration for this FR/ATM interworking connection
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

frextCircuitREMonitor 1.3.6.1.4.1.326.1.16.1.2.1.5
This object enables or disables the monitoring of Bc, Be and CIR on the Rx side of the connection, called Rate Enforcement.If set to none, no monitoring will be performed. If set to standard, Rx monitoring will drop any frames received in excess of Be, and will tag frames received in between Bc and Be
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), standard(2)  

frextCircuitRateFallbacks 1.3.6.1.4.1.326.1.16.1.2.1.6
The number of times that the insertion rate was lowered (due to network congestion reports) since the connection was created.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

frextCircuitRateFallforwards 1.3.6.1.4.1.326.1.16.1.2.1.7
The number of times that the insertion rate was increased (due to lack of network congestion reports) since the connection was created.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

frextCircuitEgFramesDroppedQueueFull 1.3.6.1.4.1.326.1.16.1.2.1.8
Number of frames which were dropped on this connection because the hold queue was full.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

frextCircuitNormalSentFrames 1.3.6.1.4.1.326.1.16.1.2.1.9
Number of frames sent on this connection within the Commited Information Rate since the connection was created.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

frextCircuitNormalSentOctets 1.3.6.1.4.1.326.1.16.1.2.1.10
Number of octets sent on this connection within the Commited Information Rate since the connection was created.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

frextCircuitExcessSentOctets 1.3.6.1.4.1.326.1.16.1.2.1.11
Number of octets sent on this connection above the Commited Information Rate, but below the Excess Information Rate since the connection was created.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

frextCircuitHeldBuffers 1.3.6.1.4.1.326.1.16.1.2.1.12
Number of buffers which were used by the connection for enqueueing frames in preference to exceeding the allowed burst rate on this connection since the connection was created.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

frextCircuitOctetsOnQueue 1.3.6.1.4.1.326.1.16.1.2.1.13
Number of octets currently being used for enqueueing frames in order to be transmited.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

frextCircuitBuffersOnQueue 1.3.6.1.4.1.326.1.16.1.2.1.14
Number of buffers currently being used for enqueueing frames in order to be transmited.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

frextCircuitRxMonNormalFrames 1.3.6.1.4.1.326.1.16.1.2.1.15
The number of frames received on the connection within the committed burst (Bc).
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

frextCircuitRxMonNormalOctets 1.3.6.1.4.1.326.1.16.1.2.1.16
The number of octets received on the connection within the committed burst (Bc).
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

frextCircuitRxMonExcessOctets 1.3.6.1.4.1.326.1.16.1.2.1.17
The number of octets received on the connection within the excess burst (Be).
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

frextCircuitRxMonDroppedOctets 1.3.6.1.4.1.326.1.16.1.2.1.18
The number of octets received on the connection that were dropped because they were in excess Bc+Be.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

frextCircuitRxMonDroppedDEFrames 1.3.6.1.4.1.326.1.16.1.2.1.19
The number of frames with the DE bit set received on the connection that were dropped.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

frextCircuitRxMonDroppedDEOctets 1.3.6.1.4.1.326.1.16.1.2.1.20
The number of octets in frames with the DE bit set received on the connection that were dropped.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

frextCircuitRxMonDEOctets 1.3.6.1.4.1.326.1.16.1.2.1.21
The number of octets with the DE bit set that were received on the connection.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

frextCircuitRxMonSetDEFrames 1.3.6.1.4.1.326.1.16.1.2.1.22
The number of frames received on the connection in which the Rx monitor set the DE bit.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

frextCircuitRxMonSetDEOctets 1.3.6.1.4.1.326.1.16.1.2.1.23
The number of octets in frames received on the connection in which the Rx monitor set the DE bit.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

frextCircuitRecvdBECNS 1.3.6.1.4.1.326.1.16.1.2.1.24
Number of frames received from the network in- dicating forward congestion since the connection was created. This object is defined in this table to provide the same object as defined in RFC 1315, while the interface is defined as a DCE.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

frextCircuitRecvdFECNS 1.3.6.1.4.1.326.1.16.1.2.1.25
Number of frames received from the network in- dicating backward congestion since the connection was created.This object is defined in this table to provide the same object as defined in RFC 1315, while the interface is defined as a DCE.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

frsOamF5Table 1.3.6.1.4.1.326.1.16.1.3
The OAM statistics table on a VCC basis
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FrsOamF5Entry

frsOamF5Entry 1.3.6.1.4.1.326.1.16.1.3.1
An Entry in the OAM F5 statistics table on a VCC basis
Status: current Access: not-accessible
OBJECT-TYPE    
  FrsOamF5Entry  

frsOamF5AtmIf 1.3.6.1.4.1.326.1.16.1.3.1.1
The Atm interface index corresponds to the port. This is also the index of the portTable.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frsOamF5AtmVpi 1.3.6.1.4.1.326.1.16.1.3.1.2
VPI of the ATM VCC on which FR DLCI maps onto
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frsOamF5AtmVci 1.3.6.1.4.1.326.1.16.1.3.1.3
VCI of the ATM VCC on which FR DLCI maps onto
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

frsOamF5AISRxCounter 1.3.6.1.4.1.326.1.16.1.3.1.4
Number of VC-AIS cells received since the PVC was brought into service.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

frsOamF5AISTxCounter 1.3.6.1.4.1.326.1.16.1.3.1.5
Number of VC-AIS cells transmited since the PVC was brought into service.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

frsOamF5RDIRxCounter 1.3.6.1.4.1.326.1.16.1.3.1.6
Number of VC-RDI cells received since the PVC was brought into service.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

frsOamF5RDITxCounter 1.3.6.1.4.1.326.1.16.1.3.1.7
Number of VC-RDI cells transmited since the PVC was brought into service.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32