Fore-Funi-MIB
File:
Fore-Funi-MIB.mib (14858 bytes)
Imported modules
Imported symbols
Defined Types
FuniConnEntry |
|
SEQUENCE |
|
|
|
|
funiConnFuniServiceIfIndex |
Integer32 |
|
|
funiConnFuniVpi |
Integer32 |
|
|
funiConnFuniVci |
Integer32 |
|
|
funiConnFabricServiceIfIndex |
Integer32 |
|
|
funiConnFabricVpi |
Integer32 |
|
|
funiConnFabricVci |
Integer32 |
|
|
funiConnRowStatus |
RowStatus |
|
|
funiConnName |
DisplayString |
|
|
funiConnAdminStatus |
INTEGER |
|
|
funiConnOperStatus |
INTEGER |
|
|
funiConnProfileEpdPpdIndex |
Integer32 |
|
FuniIfExtEntry |
|
SEQUENCE |
|
|
|
|
funiIfExtProfileFuniIndex |
Integer32 |
|
|
funiIfExtProfileServiceIndex |
Integer32 |
|
|
funiIfExtStatsMonitor |
INTEGER |
|
|
funiIfExtNeighborIpAddress |
IpAddress |
|
|
funiIfExtStatsEnabledTimeStamp |
TimeTicks |
|
|
funiIfExtSigStatus |
INTEGER |
|
Defined Values
funi |
1.3.6.1.4.1.326.1.16.6 |
write something interesting here |
MODULE-IDENTITY |
|
|
|
funiConnTable |
1.3.6.1.4.1.326.1.16.6.1 |
Table of cross connections between FUNI and ATM connections |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
FuniConnEntry |
|
funiConnEntry |
1.3.6.1.4.1.326.1.16.6.1.1 |
Entry in the FUNI/atm netmod crossconnect table |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
FuniConnEntry |
|
|
funiConnFuniVpi |
1.3.6.1.4.1.326.1.16.6.1.1.2 |
VPI of this connection on the FUNI service |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
funiConnFuniVci |
1.3.6.1.4.1.326.1.16.6.1.1.3 |
VCI of this connection on the FUNI service |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
funiConnFabricServiceIfIndex |
1.3.6.1.4.1.326.1.16.6.1.1.4 |
This is the IfIndex associated with the pseudo atm service
this connection is mapped to by the agent when this FUNI
connection is created. This IfIndex can be converted to
a BNP notation value through the IfIndexMapTable of the
fore-switch MIB. This ifIndex will be stacked on top of
the portIfIndex for a port. That BNP value can be used to
establish a connection across the switching fabric by means
of the FORE-switch MIB. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
funiConnFabricVpi |
1.3.6.1.4.1.326.1.16.6.1.1.5 |
This is the Fabric VPI of the ATM connection this FUNI
connection is mapped to by the agent when this row is
created. This VPI will be used to establish a connection
across the switching fabric by means of the FORE-switch MIB |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
funiConnFabricVci |
1.3.6.1.4.1.326.1.16.6.1.1.6 |
This is the Fabric VCI of the ATM connection this FUNI
connection is mapped to by the agent when this row is
created. This VCI will be used to establish a connection
across the switching fabric by means of the FORE-switch MIB |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
funiConnRowStatus |
1.3.6.1.4.1.326.1.16.6.1.1.7 |
This object is used for dynamic creation of entries in this
table. When the record is created, it is set to createAndWait,
when the second hop of the connection is established across
the fabric, this object's value is changed to go, which
activates the IWF on the netmod |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
RowStatus |
|
|
funiConnName |
1.3.6.1.4.1.326.1.16.6.1.1.8 |
Symbolic name assigned to this connection by the operator |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
funiConnAdminStatus |
1.3.6.1.4.1.326.1.16.6.1.1.9 |
Indicates whether the particular virtual circuit is operational. |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
INTEGER |
up(1), down(2), testing(3) |
|
funiConnOperStatus |
1.3.6.1.4.1.326.1.16.6.1.1.10 |
Indicates the current operational status of a virtual circuit. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
up(1), down(2) |
|
funiConnProfileEpdPpdIndex |
1.3.6.1.4.1.326.1.16.6.1.1.11 |
The index of the EpdPpd Controller profile which contains:
1 ) Enable/disable the EPD for CLP=0 cells for a specific connection;
2 ) Enable/disable the EPD for CLP=1 cells for a specific connection;
3 ) Enable/disable the PPD for CLP=1 cells for a specific connection. |
Status: current |
Access: read-create |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
funiIfExtTable |
1.3.6.1.4.1.326.1.16.6.2 |
This table incorporates the information pertinent to FUNI
services, which is not part of the standard FUNI mib. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
FuniIfExtEntry |
|
funiIfExtEntry |
1.3.6.1.4.1.326.1.16.6.2.1 |
Entry in the extended FUNI Interface table |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
FuniIfExtEntry |
|
|
funiIfExtProfileFuniIndex |
1.3.6.1.4.1.326.1.16.6.2.1.1 |
This is index of the FUNI profile this service is
supposed to be using. This index should be used as a key
in profileFuniTable |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
funiIfExtProfileServiceIndex |
1.3.6.1.4.1.326.1.16.6.2.1.2 |
This is index of the Generic Service profile this service is
supposed to be using. This index should be used as a key
in profileGenServiceTable |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
funiIfExtStatsMonitor |
1.3.6.1.4.1.326.1.16.6.2.1.3 |
This object specifies whether statistics are to be counted at
a service level, this includes service and connection statistics.
When the state changes from enabled to disabled all the related
statistics will be frozen at their current value. When the state
changes from disabled to enabled then all related statistics will
be reset (zeroised). Note that this Monitor is overriden by the
netmod level nmFramStatsMonitor. Refer to fore-fram.mib for more
details. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
enabled(1), disabled(2) |
|
funiIfExtNeighborIpAddress |
1.3.6.1.4.1.326.1.16.6.2.1.4 |
The IP address of the neighbor system connected to the
far end of this interface, to which a Network Management
Station can send SNMP messages, as IP datagrams sent to
UDP port 161, in order to access network management
information concerning the operation of that system. Note
that the value of this object may be obtained in different
ways, e.g., by manual configuration, or through ILMI
interaction with the neighbor system.This object is a
mirror of atmInterfaceMyNeighborIpAddress from the ATM MIB |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
IpAddress |
|
|
funiIfExtStatsEnabledTimeStamp |
1.3.6.1.4.1.326.1.16.6.2.1.5 |
This object reflects the point in time, with reference to sysUpTime,
either when funIfExtStatsMonitor is set to enabled or when
nmFramStatsMonitor is set to enabled. The time will reflect the last
StatsMonitor to be enabled. The timestamp provides a starting
timestamp for the current statistics that are being counted. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
TimeTicks |
|
|
funiIfExtSigStatus |
1.3.6.1.4.1.326.1.16.6.2.1.6 |
This object indicates whether there exists a FUNI signalling instance
associated with the FUNI service. The possible value for this object
is summarized as follows:
FUNI Signalling Support Possible Value of this object
===============================================================
disabled nonexist(2)
_______________________________________________________________
enabled exist(1)
nonexist(2)
_______________________________________________________________
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
exist(1), nonexist(2) |
|