Fore-Funi-MIB

File: Fore-Funi-MIB.mib (14858 bytes)

Imported modules

SNMPv2-SMI Fore-Common-MIB SNMPv2-TC
IF-MIB

Imported symbols

Integer32 TimeTicks IpAddress
OBJECT-TYPE MODULE-IDENTITY frameInternetworking
RowStatus DisplayString ifIndex

Defined Types

FuniConnEntry  
SEQUENCE    
  funiConnFuniServiceIfIndex Integer32
  funiConnFuniVpi Integer32
  funiConnFuniVci Integer32
  funiConnFabricServiceIfIndex Integer32
  funiConnFabricVpi Integer32
  funiConnFabricVci Integer32
  funiConnRowStatus RowStatus
  funiConnName DisplayString
  funiConnAdminStatus INTEGER
  funiConnOperStatus INTEGER
  funiConnProfileEpdPpdIndex Integer32

FuniIfExtEntry  
SEQUENCE    
  funiIfExtProfileFuniIndex Integer32
  funiIfExtProfileServiceIndex Integer32
  funiIfExtStatsMonitor INTEGER
  funiIfExtNeighborIpAddress IpAddress
  funiIfExtStatsEnabledTimeStamp TimeTicks
  funiIfExtSigStatus INTEGER

Defined Values

funi 1.3.6.1.4.1.326.1.16.6
write something interesting here
MODULE-IDENTITY    

funiConnTable 1.3.6.1.4.1.326.1.16.6.1
Table of cross connections between FUNI and ATM connections
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FuniConnEntry

funiConnEntry 1.3.6.1.4.1.326.1.16.6.1.1
Entry in the FUNI/atm netmod crossconnect table
Status: current Access: not-accessible
OBJECT-TYPE    
  FuniConnEntry  

funiConnFuniServiceIfIndex 1.3.6.1.4.1.326.1.16.6.1.1.1
Interface index of the FUNI service this connection exists on
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

funiConnFuniVpi 1.3.6.1.4.1.326.1.16.6.1.1.2
VPI of this connection on the FUNI service
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

funiConnFuniVci 1.3.6.1.4.1.326.1.16.6.1.1.3
VCI of this connection on the FUNI service
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

funiConnFabricServiceIfIndex 1.3.6.1.4.1.326.1.16.6.1.1.4
This is the IfIndex associated with the pseudo atm service this connection is mapped to by the agent when this FUNI connection is created. This IfIndex can be converted to a BNP notation value through the IfIndexMapTable of the fore-switch MIB. This ifIndex will be stacked on top of the portIfIndex for a port. That BNP value can be used to establish a connection across the switching fabric by means of the FORE-switch MIB.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

funiConnFabricVpi 1.3.6.1.4.1.326.1.16.6.1.1.5
This is the Fabric VPI of the ATM connection this FUNI connection is mapped to by the agent when this row is created. This VPI will be used to establish a connection across the switching fabric by means of the FORE-switch MIB
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

funiConnFabricVci 1.3.6.1.4.1.326.1.16.6.1.1.6
This is the Fabric VCI of the ATM connection this FUNI connection is mapped to by the agent when this row is created. This VCI will be used to establish a connection across the switching fabric by means of the FORE-switch MIB
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

funiConnRowStatus 1.3.6.1.4.1.326.1.16.6.1.1.7
This object is used for dynamic creation of entries in this table. When the record is created, it is set to createAndWait, when the second hop of the connection is established across the fabric, this object's value is changed to go, which activates the IWF on the netmod
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

funiConnName 1.3.6.1.4.1.326.1.16.6.1.1.8
Symbolic name assigned to this connection by the operator
Status: current Access: read-create
OBJECT-TYPE    
  DisplayString  

funiConnAdminStatus 1.3.6.1.4.1.326.1.16.6.1.1.9
Indicates whether the particular virtual circuit is operational.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER up(1), down(2), testing(3)  

funiConnOperStatus 1.3.6.1.4.1.326.1.16.6.1.1.10
Indicates the current operational status of a virtual circuit.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER up(1), down(2)  

funiConnProfileEpdPpdIndex 1.3.6.1.4.1.326.1.16.6.1.1.11
The index of the EpdPpd Controller profile which contains: 1 ) Enable/disable the EPD for CLP=0 cells for a specific connection; 2 ) Enable/disable the EPD for CLP=1 cells for a specific connection; 3 ) Enable/disable the PPD for CLP=1 cells for a specific connection.
Status: current Access: read-create
OBJECT-TYPE    
  Integer32  

funiIfExtTable 1.3.6.1.4.1.326.1.16.6.2
This table incorporates the information pertinent to FUNI services, which is not part of the standard FUNI mib.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FuniIfExtEntry

funiIfExtEntry 1.3.6.1.4.1.326.1.16.6.2.1
Entry in the extended FUNI Interface table
Status: current Access: not-accessible
OBJECT-TYPE    
  FuniIfExtEntry  

funiIfExtProfileFuniIndex 1.3.6.1.4.1.326.1.16.6.2.1.1
This is index of the FUNI profile this service is supposed to be using. This index should be used as a key in profileFuniTable
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

funiIfExtProfileServiceIndex 1.3.6.1.4.1.326.1.16.6.2.1.2
This is index of the Generic Service profile this service is supposed to be using. This index should be used as a key in profileGenServiceTable
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

funiIfExtStatsMonitor 1.3.6.1.4.1.326.1.16.6.2.1.3
This object specifies whether statistics are to be counted at a service level, this includes service and connection statistics. When the state changes from enabled to disabled all the related statistics will be frozen at their current value. When the state changes from disabled to enabled then all related statistics will be reset (zeroised). Note that this Monitor is overriden by the netmod level nmFramStatsMonitor. Refer to fore-fram.mib for more details.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

funiIfExtNeighborIpAddress 1.3.6.1.4.1.326.1.16.6.2.1.4
The IP address of the neighbor system connected to the far end of this interface, to which a Network Management Station can send SNMP messages, as IP datagrams sent to UDP port 161, in order to access network management information concerning the operation of that system. Note that the value of this object may be obtained in different ways, e.g., by manual configuration, or through ILMI interaction with the neighbor system.This object is a mirror of atmInterfaceMyNeighborIpAddress from the ATM MIB
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

funiIfExtStatsEnabledTimeStamp 1.3.6.1.4.1.326.1.16.6.2.1.5
This object reflects the point in time, with reference to sysUpTime, either when funIfExtStatsMonitor is set to enabled or when nmFramStatsMonitor is set to enabled. The time will reflect the last StatsMonitor to be enabled. The timestamp provides a starting timestamp for the current statistics that are being counted.
Status: current Access: read-only
OBJECT-TYPE    
  TimeTicks  

funiIfExtSigStatus 1.3.6.1.4.1.326.1.16.6.2.1.6
This object indicates whether there exists a FUNI signalling instance associated with the FUNI service. The possible value for this object is summarized as follows: FUNI Signalling Support Possible Value of this object =============================================================== disabled nonexist(2) _______________________________________________________________ enabled exist(1) nonexist(2) _______________________________________________________________
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER exist(1), nonexist(2)