FSM7326-POWER-ETHERNET-MIB

File: FSM7326-POWER-ETHERNET-MIB.mib (4114 bytes)

Imported modules

SNMPv2-SMI FSM7326-REF-MIB POWER-ETHERNET-MIB

Imported symbols

MODULE-IDENTITY OBJECT-TYPE Gauge32
fsm7326 pethPsePortEntry

Defined Types

AgentPethPsePortEntry  
SEQUENCE    
  agentPethPowerLimit Gauge32
  agentPethOutputPower Gauge32
  agentPethOutputCurrent Gauge32
  agentPethOutputVolts Gauge32

Defined Values

fsm7326powerEthernetMIB 1.3.6.1.4.1.4526.1.9.15
This MIB Augments the POWER-ETHERNET-MIB created by the IETF Ethernet Interfaces and Hub MIB Working Group for managing Power Source Equipment (PSE). The objects in this MIB are intended to provide additional objects for reporting information available to the hardware on this platform which are not represented in the draft MIB.
MODULE-IDENTITY    

agentPethObjects 1.3.6.1.4.1.4526.1.9.15.1
OBJECT IDENTIFIER    

agentPethPsePortTable 1.3.6.1.4.1.4526.1.9.15.1.1
A table of per-port information and configuration objects relating to the power status of each port.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AgentPethPsePortEntry

agentPethPsePortEntry 1.3.6.1.4.1.4526.1.9.15.1.1.1
A collection of objects providing additional power information and control parameters for the specified port.
Status: current Access: not-accessible
OBJECT-TYPE    
  AgentPethPsePortEntry  

agentPethPowerLimit 1.3.6.1.4.1.4526.1.9.15.1.1.1.1
The configured maximum power this port can provide to an attached device measured in Watts.
Status: current Access: read-write
OBJECT-TYPE    
  Gauge32 3..16  

agentPethOutputPower 1.3.6.1.4.1.4526.1.9.15.1.1.1.2
The power this port is supplying to an attached device measured in Milliwatts.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

agentPethOutputCurrent 1.3.6.1.4.1.4526.1.9.15.1.1.1.3
The current this port is supplying to an attached device measured in Milliamps.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32  

agentPethOutputVolts 1.3.6.1.4.1.4526.1.9.15.1.1.1.4
The voltage this port is supplying to an attached device measured in Volts.
Status: current Access: read-only
OBJECT-TYPE    
  Gauge32