FRDTE-OPT-MIB

File: FRDTE-OPT-MIB.mib (68262 bytes)

Imported modules

RFC1155-SMI RFC-1212

Imported symbols

mgmt NetworkAddress IpAddress
Counter Gauge TimeTicks
enterprises OBJECT-TYPE

Defined Types

Counter16  
INTEGER 0..65535    

DisplayString  
OCTET STRING    

Cdx6500PCTFRDTEPortEntry  
SEQUENCE    
  cdx6500frdtepCfgPortNum INTEGER
  cdx6500frdtepConnectionType INTEGER
  cdx6500frdtepClockSource INTEGER
  cdx6500frdtepClockSpeed INTEGER
  cdx6500frdtepMaxStations INTEGER
  cdx6500frdtepFrameSeqCounting INTEGER
  cdx6500frdtepPktSeqCounting INTEGER
  cdx6500frdtepCtrlProtocol INTEGER
  cdx6500frdtepT391 INTEGER
  cdx6500frdtepT392 INTEGER
  cdx6500frdtepN391 INTEGER
  cdx6500frdtepN392 INTEGER
  cdx6500frdtepN393 INTEGER
  cdx6500frdtepNT1 INTEGER
  cdx6500frdtepNT2 INTEGER
  cdx6500frdtepNN1 INTEGER
  cdx6500frdtepNN2 INTEGER
  cdx6500frdtepNN3 INTEGER
  cdx6500frdtepHighPriorityStn INTEGER
  cdx6500frdtepMaxVoiceBWBitsPerSec INTEGER
  cdx6500frdtepSegSizeVoicePresent INTEGER
  cdx6500frdtepSegSizeVoiceNotPresent INTEGER
  cdx6500frdtepInvertTXClock INTEGER
  cdx6500frdtepControlProtocolOptions DisplayString
  cdx6500frdtepDiscardControlOptions INTEGER
  cdx6500frdtepElectricalInterfaceType INTEGER
  cdx6500frdtepV24ElectricalInterfaceOption INTEGER
  cdx6500frdtepHighSpeedElectricalInterfaceOption INTEGER

Cdx6500PPSTFRDTEPortEntry  
SEQUENCE    
  cdx6500frdtepStatsPortNum INTEGER
  cdx6500frdtepPortStatus INTEGER
  cdx6500frdtepPortSpeed INTEGER
  cdx6500frdtepUtilizationIn INTEGER
  cdx6500frdtepUtilizationOut INTEGER
  cdx6500frdtepCharInTotal Counter
  cdx6500frdtepCharOutTotal Counter
  cdx6500frdtepCharsInPerSec INTEGER
  cdx6500frdtepCharsOutPerSec INTEGER
  cdx6500frdtepFrameInTotal Counter
  cdx6500frdtepFrameOutTotal Counter
  cdx6500frdtepFramesInPerSec INTEGER
  cdx6500frdtepFramesOutPerSec INTEGER
  cdx6500frdtepOverrunErrors Counter16
  cdx6500frdtepUnderrunErrors Counter16
  cdx6500frdtepCRCErrors Counter16

Cdx6500SPCTFRDTEStationEntry  
SEQUENCE    
  cdx6500frdtesCfgPortNum INTEGER
  cdx6500frdtesCfgDLCI INTEGER
  cdx6500frdtesStationType INTEGER
  cdx6500frdtesCommInfoRate INTEGER
  cdx6500frdtesCommBurstSize INTEGER
  cdx6500frdtesTransDelay INTEGER
  cdx6500frdtesControlledMode INTEGER
  cdx6500frdtesLinkAddress INTEGER
  cdx6500frdtesPVCChannels INTEGER
  cdx6500frdtesStartingPVC INTEGER
  cdx6500frdtesSVCChannels INTEGER
  cdx6500frdtesStartingSVC INTEGER
  cdx6500frdtesInitialFrame INTEGER
  cdx6500frdtesRetryTimer INTEGER
  cdx6500frdtesPollTimer INTEGER
  cdx6500frdtesTries INTEGER
  cdx6500frdtesFrameWinSize INTEGER
  cdx6500frdtesPacketWinSize INTEGER
  cdx6500frdtesMaxPacketSize INTEGER
  cdx6500frdtesUpperQueue INTEGER
  cdx6500frdtesLowerQueue INTEGER
  cdx6500frdtesRestartTimer INTEGER
  cdx6500frdtesResetTimer INTEGER
  cdx6500frdtesCallTimer INTEGER
  cdx6500frdtesClearTimer INTEGER
  cdx6500frdtesX25Options INTEGER
  cdx6500frdtesRCDestination DisplayString
  cdx6500frdtesCUG DisplayString
  cdx6500frdtesBillingRecords INTEGER
  cdx6500frdtesCfgStationNum INTEGER
  cdx6500frdtesStnX25Options DisplayString
  cdx6500frdtesStnFrameSegmenter INTEGER
  cdx6500frdtesStnVoiceSVCChannels INTEGER
  cdx6500frdtesStnVoiceCongCtrlMode INTEGER
  cdx6500frdtesStnPeakUtilization INTEGER
  cdx6500frdtesStnMaxInboundQueue INTEGER
  cdx6500frdtesStnAnnexGRateReduction INTEGER

Cdx6500SPSTFRDTEStationEntry  
SEQUENCE    
  cdx6500frdtesStatsPortNum INTEGER
  cdx6500frdtesStatsDLCI INTEGER
  cdx6500frdtesUtilizationIn INTEGER
  cdx6500frdtesUtilizationOut INTEGER
  cdx6500frdtesMaxSVCCount INTEGER
  cdx6500frdtesCurrentSVCCount INTEGER
  cdx6500frdtesCharInTotal Counter
  cdx6500frdtesCharOutTotal Counter
  cdx6500frdtesCharsInPerSec INTEGER
  cdx6500frdtesCharsOutPerSec INTEGER
  cdx6500frdtesPktInTotal Counter
  cdx6500frdtesPktOutTotal Counter
  cdx6500frdtesPktsInPerSec INTEGER
  cdx6500frdtesPktsOutPerSec INTEGER
  cdx6500frdtesPacketsQueued INTEGER
  cdx6500frdtesFrameInTotal Counter
  cdx6500frdtesFrameOutTotal Counter
  cdx6500frdtesFramesInPerSec INTEGER
  cdx6500frdtesFramesOutPerSec INTEGER
  cdx6500frdtesInfoFramesIn Counter
  cdx6500frdtesInfoFramesOut Counter
  cdx6500frdtesRNRFramesIn Counter
  cdx6500frdtesRNRFramesOut Counter
  cdx6500frdtesRRFramesIn Counter
  cdx6500frdtesRRFramesOut Counter
  cdx6500frdtesREJFramesIn Counter
  cdx6500frdtesREJFramesOut Counter
  cdx6500frdtesDataPktsIn Counter
  cdx6500frdtesDataPktsOut Counter
  cdx6500frdtesResetStats INTEGER
  cdx6500frdtesBoot INTEGER
  cdx6500frdtesDisable INTEGER
  cdx6500frdtesEnable INTEGER
  cdx6500frdtesStatsStationNumber INTEGER

Defined Values

codex 1.3.6.1.4.1.449
OBJECT IDENTIFIER    

cdxProductSpecific 1.3.6.1.4.1.449.2
OBJECT IDENTIFIER    

cdx6500 1.3.6.1.4.1.449.2.1
OBJECT IDENTIFIER    

cdx6500Configuration 1.3.6.1.4.1.449.2.1.2
OBJECT IDENTIFIER    

cdx6500CfgProtocolGroup 1.3.6.1.4.1.449.2.1.2.1
OBJECT IDENTIFIER    

cdx6500PCTPortProtocolGroup 1.3.6.1.4.1.449.2.1.2.1.1
OBJECT IDENTIFIER    

cdx6500PCTStationProtocolGroup 1.3.6.1.4.1.449.2.1.2.1.3
OBJECT IDENTIFIER    

cdx6500Statistics 1.3.6.1.4.1.449.2.1.3
OBJECT IDENTIFIER    

cdx6500StatProtocolGroup 1.3.6.1.4.1.449.2.1.3.1
OBJECT IDENTIFIER    

cdx6500PSTPortProtocolGroup 1.3.6.1.4.1.449.2.1.3.1.1
OBJECT IDENTIFIER    

cdx6500PSTStationProtocolGroup 1.3.6.1.4.1.449.2.1.3.1.3
OBJECT IDENTIFIER    

cdx6500Controls 1.3.6.1.4.1.449.2.1.4
OBJECT IDENTIFIER    

cdx6500PCTFRDTEPortTable 1.3.6.1.4.1.449.2.1.2.1.1.5
All of the configuration parameters relevant to the Frame Relay DTE Port table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Cdx6500PCTFRDTEPortEntry

cdx6500PCTFRDTEPortEntry 1.3.6.1.4.1.449.2.1.2.1.1.5.1
A row of FRI Port configuration parameters.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Cdx6500PCTFRDTEPortEntry  

cdx6500frdtepCfgPortNum 1.3.6.1.4.1.449.2.1.2.1.1.5.1.1
Specifies the Port number for the Frame Relay Interface port you are selecting.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

cdx6500frdtepConnectionType 1.3.6.1.4.1.449.2.1.2.1.1.5.1.2
Specify the control signal handshake and clocking required for a connection to be made to this port: simp - simple, no control signals required dtr - dedicated, require the data terminal ready signal (DTR) simpb - simple, no control signals required for data transmission and reception. By default output leads will be low. nc - Skipped during configuration.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER simp(1), dtr(2), simpb(21), nc(100)  

cdx6500frdtepClockSource 1.3.6.1.4.1.449.2.1.2.1.1.5.1.3
int - internal clock source ext - external clock source extint - Internal receive and external transmit clock source (DCE only). extlp - external receive and loopback transmit clock source (DTE only). EXTLP must be configured in conjunction with EXTINT. nc - Skipped during configuration.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER int(1), ext(2), extint(3), extlp(4), nc(100)  

cdx6500frdtepClockSpeed 1.3.6.1.4.1.449.2.1.2.1.1.5.1.4
This is the speed of the port in bits per second, when using internal clocking. The highest available speed is dependent on the card type,and on the interface type.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1200..2048000  

cdx6500frdtepMaxStations 1.3.6.1.4.1.449.2.1.2.1.1.5.1.5
This is the highest station number to be configured on this FRI port. It is used to limit the configuration of stations.
Status: deprecated Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500frdtepFrameSeqCounting 1.3.6.1.4.1.449.2.1.2.1.1.5.1.6
Port uses normal or extended frame sequence numbering: normal - normal sequencing (modulo 8) ext - extended sequencing (modulo 128) nc - Skipped during configuration. All stations on this port will be set to this value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER normal(1), extended(2), nc(100)  

cdx6500frdtepPktSeqCounting 1.3.6.1.4.1.449.2.1.2.1.1.5.1.7
Port uses normal or extended packet level sequence numbers normal - normal sequencing (Modulo 8) ext - extended sequencing (Modulo 128) nc - Skipped during configuration. This parameter must be set to the same value at both this FRI port and the remote FRI port. All stations on this port will be set to this value.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER normal(1), extended(2), nc(100)  

cdx6500frdtepCtrlProtocol 1.3.6.1.4.1.449.2.1.2.1.1.5.1.8
Whether ANSI T1.617 Annex D or LMI Support is enabled none - None is enabled. annexD - Annex D is enabled lmi - LMI is enabled. annexA - Annex A is enabled. auto - Auto-learn the Network control protocol type nc - Skipped during configuration.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER annexD(1), none(2), lmi(3), annexA(4), auto(5), nc(100)  

cdx6500frdtepT391 1.3.6.1.4.1.449.2.1.2.1.1.5.1.9
This parameter is the Link Integrity Verification Timer polling period. The FRI port sends status enquiry messages to network every T391/nT1 seconds.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 5..30  

cdx6500frdtepT392 1.3.6.1.4.1.449.2.1.2.1.1.5.1.10
This parameter is the polling Cycle Verification Timer period. The FRI port expects status enquiry messages every T392/nT2 seconds. This parameter must be set to a value greater than N391/nT1, and applies only in bi-directional mode.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 5..30  

cdx6500frdtepN391 1.3.6.1.4.1.449.2.1.2.1.1.5.1.12
Full Status polling cycle. FRI port sends Full status enquiry messages to network every nN1 polls.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

cdx6500frdtepN392 1.3.6.1.4.1.449.2.1.2.1.1.5.1.13
Error inactivity threshold. Number of errors during NN3 events that cause the station to be declared inactive. Should be less than or equal to nN3.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500frdtepN393 1.3.6.1.4.1.449.2.1.2.1.1.5.1.14
Monitored events count for measuring nN3. nN2 errors during nN3 events will cause the station to be declared inactive. Should be greater than nN3.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

cdx6500frdtepNT1 1.3.6.1.4.1.449.2.1.2.1.1.5.1.15
This parameter is the Link Integrity Verification Timer polling period. The FRI port sends status enquiry messages to network every T391/nT1 seconds.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 5..30  

cdx6500frdtepNT2 1.3.6.1.4.1.449.2.1.2.1.1.5.1.16
This parameter is the polling Cycle Verification Timer period. The FRI port expects status enquiry messages every T392/nT2 seconds. This parameter must be set to a value greater than N391/nT1, and applies only in bi-directional mode.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 5..30  

cdx6500frdtepNN1 1.3.6.1.4.1.449.2.1.2.1.1.5.1.17
Full Status polling cycle. FRI port sends Full status enquiry messages to network every nN1 polls.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500frdtepNN2 1.3.6.1.4.1.449.2.1.2.1.1.5.1.18
Error inactivity threshold. Number of errors during NN3 events that cause the station to be declared inactive. Should be less than or equal to nN3.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

cdx6500frdtepNN3 1.3.6.1.4.1.449.2.1.2.1.1.5.1.19
Monitored events count for measuring nN3. nN2 errors during nN3 events will cause the station to be declared inactive. Should be greater than nN3.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500frdtepHighPriorityStn 1.3.6.1.4.1.449.2.1.2.1.1.5.1.20
This parameter specifies a station who's PVC status has priority over all other stations when FRI same port back up is enabled. When the network reports this DLCI inactive, an alternate connection over a backup link is attempted.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 1..254  

cdx6500frdtepMaxVoiceBWBitsPerSec 1.3.6.1.4.1.449.2.1.2.1.1.5.1.21
This parameter limits the bandwidth, in bits per sec (including overhead), for voice traffic passing through this frame relay port. A zero value disables any voice passing through this port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..2048000  

cdx6500frdtepSegSizeVoicePresent 1.3.6.1.4.1.449.2.1.2.1.1.5.1.22
Data packets to be segmented into this maximum frame size when voice is active on this port. segSize32 - 32 byte segments segSize64 - 64 byte segments segSize128 - 128 byte segments segSize256 - 256 byte segments segSize512 - 512 byte segments segSize1024 - 1024 byte segments nc - Skipped during configuration.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER segSize32(33), segSize64(65), segSize128(129), segSize256(257), segSize512(513), segSize1024(1025), nc(100)  

cdx6500frdtepSegSizeVoiceNotPresent 1.3.6.1.4.1.449.2.1.2.1.1.5.1.23
Data packets to be segmented into this maximum frame size when voice is not active on this port. segSize32 - 32 byte segments segSize64 - 64 byte segments segSize128 - 128 byte segments segSize256 - 256 byte segments segSize512 - 512 byte segments segSize1024 - 1024 byte segments segSize2048 - 2048 byte segments segSize4096 - 4096 byte segments disable - segment size is 32768 bytes nc - Skipped during configuration.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER segSize32(33), segSize64(65), segSize128(129), segSize256(257), segSize512(513), segSize1024(1025), segSize2048(2049), segSize4096(4097), disable(32000), nc(100)  

cdx6500frdtepInvertTXClock 1.3.6.1.4.1.449.2.1.2.1.1.5.1.24
This parameter specifies whether the phase of the transmit clock should be inverted. Note: This parameter is primarily for X.21 electrical interfaces. no - Don't invert. yes - Invert.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2), nc(100)  

cdx6500frdtepControlProtocolOptions 1.3.6.1.4.1.449.2.1.2.1.1.5.1.25
These options control the PVC management protocol none - No option selected async - The port will send/receive asynchronous A-bit if it is performing Network side protocol functionality nbit - The port will send and accept N-bit messages dbit - The port will send and accept D-bit messages This forces ASYNC to be specified (dbit+async)
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..16)  

cdx6500frdtepDiscardControlOptions 1.3.6.1.4.1.449.2.1.2.1.1.5.1.26
This parameter controls the discard frame options none - No option selected debit - DE marked frames are discarded before non-DE frames
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), debit(2)  

cdx6500frdtepElectricalInterfaceType 1.3.6.1.4.1.449.2.1.2.1.1.5.1.27
Specify the Electrical Interface Type: V.24 - V.24 Electrical Interface Type V.35 - V.35 Electrical Interface Type V.36 - V.36 Electrical Interface Type X.21 - X.21 Electrical Interface Type NONE - Electrically disabled
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER v24(1), v35(2), v36(3), x21(4), none(5)  

cdx6500frdtepV24ElectricalInterfaceOption 1.3.6.1.4.1.449.2.1.2.1.1.5.1.28
Specify the Pin 22 option: RI - V.24 uses Pin 22 for Ring Indicator output signal TM - V.24 uses Pin 22 for Test Mode input signal
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER ri(1), tm(2)  

cdx6500frdtepHighSpeedElectricalInterfaceOption 1.3.6.1.4.1.449.2.1.2.1.1.5.1.29
Specify the cable type: NONE - V.35/V.36/X.21 DCE with straight through cable XOVER - V.35/V.36/X.21 DCE with crossover adapter cable
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), xover(2)  

cdx6500PPSTFRDTEPortTable 1.3.6.1.4.1.449.2.1.3.1.1.5
All of the statistics parameters relevant to the Frame Relay DTE Port table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Cdx6500PPSTFRDTEPortEntry

cdx6500PPSTFRDTEPortEntry 1.3.6.1.4.1.449.2.1.3.1.1.5.1
A row of Frame Relay DTE Port statistics parameters.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Cdx6500PPSTFRDTEPortEntry  

cdx6500frdtepStatsPortNum 1.3.6.1.4.1.449.2.1.3.1.1.5.1.1
Specifies a specific port in the network diagram.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

cdx6500frdtepPortStatus 1.3.6.1.4.1.449.2.1.3.1.1.5.1.2
Specifies the current port status. disabled - Port has been disabled. enabled - Port is operational. busyOut - Port has been busied out. up - Port is operational. down - Port is down. na - Value not Available.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2), busyOut(3), up(4), down(5), na(100)  

cdx6500frdtepPortSpeed 1.3.6.1.4.1.449.2.1.3.1.1.5.1.3
Message transmition speed in bps.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500frdtepUtilizationIn 1.3.6.1.4.1.449.2.1.3.1.1.5.1.4
Factor determined by comparison of volume (characters per second) of data and clock rate for a specific port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

cdx6500frdtepUtilizationOut 1.3.6.1.4.1.449.2.1.3.1.1.5.1.5
Factor determined by comparison of volume (characters per second) of data and clock rate for a specific port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

cdx6500frdtepCharInTotal 1.3.6.1.4.1.449.2.1.3.1.1.5.1.6
Number of characters received since last boot or statistics reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500frdtepCharOutTotal 1.3.6.1.4.1.449.2.1.3.1.1.5.1.7
Number of characters transmitted since last boot or statistics reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500frdtepCharsInPerSec 1.3.6.1.4.1.449.2.1.3.1.1.5.1.8
Average number of characters received per second.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500frdtepCharsOutPerSec 1.3.6.1.4.1.449.2.1.3.1.1.5.1.9
Average number of characters transmitted per second.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500frdtepFrameInTotal 1.3.6.1.4.1.449.2.1.3.1.1.5.1.10
Number of frames received since last boot or statistics reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500frdtepFrameOutTotal 1.3.6.1.4.1.449.2.1.3.1.1.5.1.11
Number of frames transmitted since last boot or statistics reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500frdtepFramesInPerSec 1.3.6.1.4.1.449.2.1.3.1.1.5.1.12
Average number of frames received per second.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500frdtepFramesOutPerSec 1.3.6.1.4.1.449.2.1.3.1.1.5.1.13
Average number of frames transmitted per second.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500frdtepOverrunErrors 1.3.6.1.4.1.449.2.1.3.1.1.5.1.14
An input buffer overflowed and characters were discarded.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter16  

cdx6500frdtepUnderrunErrors 1.3.6.1.4.1.449.2.1.3.1.1.5.1.15
Number of errors detected since last node boot or reset of statistics.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter16  

cdx6500frdtepCRCErrors 1.3.6.1.4.1.449.2.1.3.1.1.5.1.16
Number of errors detected by Cyclic Redundancy Check since last node boot reset of statistics.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter16  

cdx6500SPCTFRDTEStationTable 1.3.6.1.4.1.449.2.1.2.1.3.2
All of the configuration parameters relevant to the Frame Relay DTE Station table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Cdx6500SPCTFRDTEStationEntry

cdx6500SPCTFRDTEStationEntry 1.3.6.1.4.1.449.2.1.2.1.3.2.1
A row of Frame Realy DTE station configuration parameters.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Cdx6500SPCTFRDTEStationEntry  

cdx6500frdtesCfgPortNum 1.3.6.1.4.1.449.2.1.2.1.3.2.1.1
FR DTE Port number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

cdx6500frdtesCfgDLCI 1.3.6.1.4.1.449.2.1.2.1.3.2.1.2
The Data Link Connection Identifier (dlci) is the unique identifier for the station on the FRI Port. Its valid range is 16 - 1007. It must match the DLCI configured on the FR Networking Node.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 16..1007  

cdx6500frdtesStationType 1.3.6.1.4.1.449.2.1.2.1.3.2.1.3
Identifies the type of station being configured. annexG - This station uses X.25 signaling for layer 3 bypass - This station type bypasses layer 3. There is no signaling for SVC's on this station. voiceRelay - Not used in the current version.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER annexG(1), bypass(2), voiceRelay(3)  

cdx6500frdtesCommInfoRate 1.3.6.1.4.1.449.2.1.2.1.3.2.1.4
This parameter (CIR) specifies the rate (in bits-per-second) that the Frame Relay network agrees to transfer information under congested conditions for the FRI Station. This value is used to throttle data on the FRI station for congestion control purposes. The CIR cannot be greater than the link speed.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

cdx6500frdtesCommBurstSize 1.3.6.1.4.1.449.2.1.2.1.3.2.1.5
This parameter (BC) specifies the maximum amount of data (in bits) that the Frame Relay network agrees to transfer over a time interval T = Committed Burst Size / Committed Information Rate. Must be > 1/20th of the Committed Information Rate. This is used for congestion control purposes.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

cdx6500frdtesTransDelay 1.3.6.1.4.1.449.2.1.2.1.3.2.1.6
This parameter is the expected one-way delay through the network. This is specified in milliseconds.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

cdx6500frdtesControlledMode 1.3.6.1.4.1.449.2.1.2.1.3.2.1.7
This parameter controls the method of congestion control: normal - congestion control is normal disable - never enter Congested State (CTRL) congested - never enter a Non-Congested State (UCTRL) limit - congestion control is normal but limits the data rate to no lower than CIR. nc - Skipped during configuration
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER normal(1), disable(2), congested(3), limit(4), nc(100)  

cdx6500frdtesLinkAddress 1.3.6.1.4.1.449.2.1.2.1.3.2.1.8
The logical link address must be set to complementary values in this FRI station and its corresponding remote FRI station: dte - station to have logical DTE address (A) dce - station to have logical DCE address (B) nc - Skipped during configuration.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER dte(1), dce(2), nc(100)  

cdx6500frdtesPVCChannels 1.3.6.1.4.1.449.2.1.2.1.3.2.1.9
Number of logical channels used for Permanent Virtual Circuits. The total number of PVC and SVC channels on a station (logical link) should be kept as small as possible and consistent with needs. PVC connections must be configured in the PVC Table.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

cdx6500frdtesStartingPVC 1.3.6.1.4.1.449.2.1.2.1.3.2.1.10
This is the starting logical channel number for the Permanent Virtual Circuits on this FRI station. Not used if the number of PVCs = 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

cdx6500frdtesSVCChannels 1.3.6.1.4.1.449.2.1.2.1.3.2.1.11
Number of logical channels used in Switched Virtual Circuits. The total number of PVC and SVC channels on a station (logical link) should be kept as small as possible and consistent with needs.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

cdx6500frdtesStartingSVC 1.3.6.1.4.1.449.2.1.2.1.3.2.1.12
This is the starting logical channel number for the Switched Virtual Circuits on this station (logical link). Not used if the number of SVCs = 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

cdx6500frdtesInitialFrame 1.3.6.1.4.1.449.2.1.2.1.3.2.1.13
Specify the initial frame required by other end for (logical) link startup: none - do nothing (other end initiates link-up) sabm - send SABM disc - send DISC, then SABM nc - Skipped during configuration
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER sabm(1), disc(2), none(3), nc(100)  

cdx6500frdtesRetryTimer 1.3.6.1.4.1.449.2.1.2.1.3.2.1.14
T1 link retry timer value in tenths of a second (e.g. 30 = 3.0 seconds).
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

cdx6500frdtesPollTimer 1.3.6.1.4.1.449.2.1.2.1.3.2.1.15
This sets the time an idle link is probed for assurance of connection to the remote FRI station. 0 - disable the timer X - X is in tenths of a second (e.g. 40 = 4.0 seconds) and must be set greater than T1.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

cdx6500frdtesTries 1.3.6.1.4.1.449.2.1.2.1.3.2.1.16
The maximum number of attempts allowed to complete a transmission.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

cdx6500frdtesFrameWinSize 1.3.6.1.4.1.449.2.1.2.1.3.2.1.17
Frame level window size must be set to the same value at both this FRI station and the remote FRI station.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

cdx6500frdtesPacketWinSize 1.3.6.1.4.1.449.2.1.2.1.3.2.1.18
Packet level window size must be set to the same value at both this FRI station and the remote FRI station.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

cdx6500frdtesMaxPacketSize 1.3.6.1.4.1.449.2.1.2.1.3.2.1.19
This is the maximum X.25 packet size used on the station (logical link). For proper operation, this must be set to the same value at both this FRI station and the remote FRI station. nc - Skipped during configuration.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER psize32(6), psize64(7), psize128(8), psize256(9), psize512(10), psize1024(11), nc(100)  

cdx6500frdtesUpperQueue 1.3.6.1.4.1.449.2.1.2.1.3.2.1.20
This is the maximum number of data packets a channel on this station (logical link) will queue for transmission before invoking flow control to the attached channel
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

cdx6500frdtesLowerQueue 1.3.6.1.4.1.449.2.1.2.1.3.2.1.21
This is the number of data packets a channel on this FRI station will have queued for transmission when it releases flow control to the attached channel
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

cdx6500frdtesRestartTimer 1.3.6.1.4.1.449.2.1.2.1.3.2.1.22
Restart-Request timeout timer in seconds. If timer expires on this FRI station, the Restart request is sent again.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

cdx6500frdtesResetTimer 1.3.6.1.4.1.449.2.1.2.1.3.2.1.23
Reset-Request timeout timer in seconds. If timer expires on this FRI station, the Reset request is sent again.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

cdx6500frdtesCallTimer 1.3.6.1.4.1.449.2.1.2.1.3.2.1.24
Call-Request timeout timer in seconds. If timer expires on this FRI station, the call is cleared.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

cdx6500frdtesClearTimer 1.3.6.1.4.1.449.2.1.2.1.3.2.1.25
Clear-Request timeout timer in seconds. If timer expires on this FRI station, the Clear request is sent again.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

cdx6500frdtesX25Options 1.3.6.1.4.1.449.2.1.2.1.3.2.1.26
Select X.25 options on this station (logical link) as follows: NONE - no option specified CUG - check closed user group; otherwise, CUG passes transparently CAUSE - pass cause, diagnostic, code in outbound packets HOLD - hold calls over link restart INL - inter-node link. Link goes to another 6500 device DELAY - Enable Delay and Path Trace on this link (link must be connected to Rel. 4.xx node) Any combination of above specified by summing (e.g. CUG+CAUSE+. . .). NOTE: Please use cdx6500frdtesStnX25Options, which has been added to replace this object.
Status: deprecated Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500frdtesRCDestination 1.3.6.1.4.1.449.2.1.2.1.3.2.1.27
All calls entering this station will be routed to the destination specified in this parameter, irrespective of route selection table entries. For example, to route all calls to X.25 port 3, use X25-3. To route calls to FRI port 2, station 4, use FRI-2S4. Blank this field to disable this function.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..255)  

cdx6500frdtesCUG 1.3.6.1.4.1.449.2.1.2.1.3.2.1.28
The station may be a member of up to 8 different Closed User Groups (CUGs). Each CUG membership must be a two digit number and separated by a comma. (e.g. 12,34,56,09,02,03 ). Two hyphens following each oher indicates no CUG Membership 00-99 - CUG Membership
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..23)  

cdx6500frdtesBillingRecords 1.3.6.1.4.1.449.2.1.2.1.3.2.1.29
This controls whether billing (accounting) records will be created for calls on this FRI station. off - Billing records will not be created. on - Billing records will be created. nc - Skipped during configuration.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2), nc(100)  

cdx6500frdtesCfgStationNum 1.3.6.1.4.1.449.2.1.2.1.3.2.1.30
The number of the logical link on the line. This is the value of Sxx for routing purposes.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500frdtesStnX25Options 1.3.6.1.4.1.449.2.1.2.1.3.2.1.31
Select X.25 options on this station (logical link) as follows: NONE - no option specified CUG - check closed user group; otherwise, CUG passes transparently CAUSE - pass cause, diagnostic, code in outbound packets HOLD - hold calls over link restart INL - inter-node link. Link goes to another 6500 device DELAY - Enable Delay and Path Trace on this link (link must be connected to Rel. 4.xx node) Any combination of above specified by summing (e.g. CUG+CAUSE+. . .). NOTE: This object has been added to replace cdx6500frdtesX25Options.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..24)  

cdx6500frdtesStnFrameSegmenter 1.3.6.1.4.1.449.2.1.2.1.3.2.1.32
Determine if this station will support the Frame Segmenter Header.The Frame Segmenter should be enabled if the frame relay port is configured to pass voice traffic. disabled - Frame Segmenter disabled. enabled - Frame Segmenter enabled. nc - Skipped during configuration.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2), nc(100)  

cdx6500frdtesStnVoiceSVCChannels 1.3.6.1.4.1.449.2.1.2.1.3.2.1.33
Number of logical voice channels used in Switched Virtual Circuits.The total number of voice and data channels on a station (logical link) should be kept as small as possible and consistent with needs.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..15  

cdx6500frdtesStnVoiceCongCtrlMode 1.3.6.1.4.1.449.2.1.2.1.3.2.1.34
This parameter controls the method of voice congestion control: enabled - Station is forced into congestion when voice calls are detected. disabled - Station operates normally Use this parameter in voice applications, when the frame relay network can have more than 140ms of data buffered. One typical application is asymmetrical speeds. When this parameter is enabled, and voice is detected, delta T is forced to 50 ms and the BC is forced to 1/20 CIR.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2), nc(100)  

cdx6500frdtesStnPeakUtilization 1.3.6.1.4.1.449.2.1.2.1.3.2.1.35
The monitoring interval size specifies the time period to use when monitoring peak data link/CIR (Committed Information Rate) utilization. 0 - Disables this monitoring feature. 1 to 240 - The number of 64 second increments to use for the monitoring interval time period. For example: a value of 30 specifies a time duration equal to 30 * 64 seconds = 1920 seconds or 32 minutes.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..240  

cdx6500frdtesStnMaxInboundQueue 1.3.6.1.4.1.449.2.1.2.1.3.2.1.36
This specifies the maximum number of frames from the network which may be queued in a BYPASS station. A smaller value may ve choosen for applications which experience objectable delays, if due to excessive growth of the BYPASS inbound queue.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 100..2500  

cdx6500frdtesStnAnnexGRateReduction 1.3.6.1.4.1.449.2.1.2.1.3.2.1.37
This parameter determines whether Annex G stations will invoke implicit congestion control when a link error is detected, reducing their transmitted information rate to 1/4 CIR. The rate will be gradually increased in the normal way as non-BECN frames are received.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER disabled(1), enabled(2), nc(100)  

cdx6500SPSTFRDTEStationTable 1.3.6.1.4.1.449.2.1.3.1.3.2
All of the statistics parameters relevant to the Frame Relay DTE Station (DLCI) table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Cdx6500SPSTFRDTEStationEntry

cdx6500SPSTFRDTEStationEntry 1.3.6.1.4.1.449.2.1.3.1.3.2.1
A row of Frame Relay DTE station (DLCI) Statistics parameters.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Cdx6500SPSTFRDTEStationEntry  

cdx6500frdtesStatsPortNum 1.3.6.1.4.1.449.2.1.3.1.3.2.1.1
Specifies a specific port in the network diagram.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

cdx6500frdtesStatsDLCI 1.3.6.1.4.1.449.2.1.3.1.3.2.1.2
Data Link Connection Identifier is the unique identifier for the station on the FRI port and must match the DLCI configured on the Frame Relay networking node.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 16..1007  

cdx6500frdtesUtilizationIn 1.3.6.1.4.1.449.2.1.3.1.3.2.1.3
Indicates the quantity of user bytes sent down the link expressed as a percentage of the maximum number of bytes that could have been sent.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

cdx6500frdtesUtilizationOut 1.3.6.1.4.1.449.2.1.3.1.3.2.1.4
Indicates the quantity of user bytes sent down the link expressed as a percentage of the maximum number of bytes that could have been sent.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

cdx6500frdtesMaxSVCCount 1.3.6.1.4.1.449.2.1.3.1.3.2.1.5
Maximum number of SVCs available in the network.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500frdtesCurrentSVCCount 1.3.6.1.4.1.449.2.1.3.1.3.2.1.6
Current number of SVCs currently in use.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500frdtesCharInTotal 1.3.6.1.4.1.449.2.1.3.1.3.2.1.7
Number of characters received since last node boot or statistics reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500frdtesCharOutTotal 1.3.6.1.4.1.449.2.1.3.1.3.2.1.8
Number of characters transmitted since last node boot or statistics reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500frdtesCharsInPerSec 1.3.6.1.4.1.449.2.1.3.1.3.2.1.9
Average number of characters received per second.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500frdtesCharsOutPerSec 1.3.6.1.4.1.449.2.1.3.1.3.2.1.10
Average number of characters transmitted per second.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500frdtesPktInTotal 1.3.6.1.4.1.449.2.1.3.1.3.2.1.11
Number of packets received since last node boot or statistics reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500frdtesPktOutTotal 1.3.6.1.4.1.449.2.1.3.1.3.2.1.12
Number of packets transmitted since last node boot or statistics reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500frdtesPktsInPerSec 1.3.6.1.4.1.449.2.1.3.1.3.2.1.13
Average number of packets received per second.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500frdtesPktsOutPerSec 1.3.6.1.4.1.449.2.1.3.1.3.2.1.14
Average number of packets transmitted per second.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500frdtesPacketsQueued 1.3.6.1.4.1.449.2.1.3.1.3.2.1.15
Current number of packets buffered since last node boot or statistics reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500frdtesFrameInTotal 1.3.6.1.4.1.449.2.1.3.1.3.2.1.16
Number of frames received since last node boot or statistics reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500frdtesFrameOutTotal 1.3.6.1.4.1.449.2.1.3.1.3.2.1.17
Number of frames transmitted since last node boot or statistics reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500frdtesFramesInPerSec 1.3.6.1.4.1.449.2.1.3.1.3.2.1.18
Average number of frames received per second.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500frdtesFramesOutPerSec 1.3.6.1.4.1.449.2.1.3.1.3.2.1.19
Average number of frames transmitted per second.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500frdtesInfoFramesIn 1.3.6.1.4.1.449.2.1.3.1.3.2.1.20
Data received since last node boot or statistics reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500frdtesInfoFramesOut 1.3.6.1.4.1.449.2.1.3.1.3.2.1.21
Data transmitted since last node boot or statistics reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500frdtesRNRFramesIn 1.3.6.1.4.1.449.2.1.3.1.3.2.1.22
Used by the DTE or the network to request that the data flow be stopped on a particular virtual circuit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500frdtesRNRFramesOut 1.3.6.1.4.1.449.2.1.3.1.3.2.1.23
Used by the DTE or the network to request that the data flow be stopped on a particular virtual circuit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500frdtesRRFramesIn 1.3.6.1.4.1.449.2.1.3.1.3.2.1.24
Used to clear the RNR request.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500frdtesRRFramesOut 1.3.6.1.4.1.449.2.1.3.1.3.2.1.25
Used to clear the RNR request.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500frdtesREJFramesIn 1.3.6.1.4.1.449.2.1.3.1.3.2.1.26
A REJ transmitted by a receiver requests retransmission of a frame, due to detection of a transmission or frame sequence error.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500frdtesREJFramesOut 1.3.6.1.4.1.449.2.1.3.1.3.2.1.27
A REJ transmitted by a receiver requests retransmission of a frame, due to detection of a transmission or frame sequence error.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500frdtesDataPktsIn 1.3.6.1.4.1.449.2.1.3.1.3.2.1.28
A packet containing user information.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500frdtesDataPktsOut 1.3.6.1.4.1.449.2.1.3.1.3.2.1.29
A packet containing user information.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500frdtesResetStats 1.3.6.1.4.1.449.2.1.3.1.3.2.1.30
Resets the specified Frame Relay station statistics. reset - Reset station statistics. noReset - Do not reset station statistics.
Status: mandatory Access: write-only
OBJECT-TYPE    
  INTEGER reset(1), noReset(2)  

cdx6500frdtesBoot 1.3.6.1.4.1.449.2.1.3.1.3.2.1.31
Boots the specified Frame Relay station. boot - Boot station. noBoot - Do not boot station.
Status: mandatory Access: write-only
OBJECT-TYPE    
  INTEGER boot(1), noBoot(2)  

cdx6500frdtesDisable 1.3.6.1.4.1.449.2.1.3.1.3.2.1.32
Disables the specified Frame Relay station. disable - Disable station. noDisable - Do not disable station.
Status: mandatory Access: write-only
OBJECT-TYPE    
  INTEGER disable(1), noDisable(2)  

cdx6500frdtesEnable 1.3.6.1.4.1.449.2.1.3.1.3.2.1.33
Enables the specified Frame Relay station. enable - Enable station. noEnable - Do not enable station.
Status: mandatory Access: write-only
OBJECT-TYPE    
  INTEGER enable(1), noEnable(2)  

cdx6500frdtesStatsStationNumber 1.3.6.1.4.1.449.2.1.3.1.3.2.1.34
The number of the FRI Station.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER