FRDCE-OPT-MIB

File: FRDCE-OPT-MIB.mib (50993 bytes)

Imported modules

RFC1155-SMI RFC-1212

Imported symbols

mgmt NetworkAddress IpAddress
Counter Gauge TimeTicks
enterprises OBJECT-TYPE

Defined Types

Counter16  
INTEGER 0..65535    

DisplayString  
OCTET STRING    

PhysAddress  
OCTET STRING    

Cdx6500PCTFRDCEPortEntry  
SEQUENCE    
  cdx6500frdcepCfgPortNum INTEGER
  cdx6500frdcepConnectionType INTEGER
  cdx6500frdcepClockSource INTEGER
  cdx6500frdcepClockSpeed INTEGER
  cdx6500frdcepMaxStations INTEGER
  cdx6500frdcepCtrlProtocol INTEGER
  cdx6500frdcepT391 INTEGER
  cdx6500frdcepT392 INTEGER
  cdx6500frdcepN391 INTEGER
  cdx6500frdcepN392 INTEGER
  cdx6500frdcepN393 INTEGER
  cdx6500frdcepNT1 INTEGER
  cdx6500frdcepNT2 INTEGER
  cdx6500frdcepNN1 INTEGER
  cdx6500frdcepNN2 INTEGER
  cdx6500frdcepNN3 INTEGER
  cdx6500frdcepSubaddress DisplayString
  cdx6500frdcepBiDirAnnexD INTEGER
  cdx6500frdcepInvertTXClock INTEGER
  cdx6500frdcepControlProtocolOptions DisplayString
  cdx6500frdcepDiscardControlOptions INTEGER
  cdx6500frdcepElectricalInterfaceType INTEGER
  cdx6500frdcepV24ElectricalInterfaceOption INTEGER
  cdx6500frdcepHighSpeedElectricalInterfaceOption INTEGER

Cdx6500PPSTFRDCEPortEntry  
SEQUENCE    
  cdx6500frdcepStatsPortNum INTEGER
  cdx6500frdcepPortStatus INTEGER
  cdx6500frdcepPortSpeed INTEGER
  cdx6500frdcepUtilizationIn INTEGER
  cdx6500frdcepUtilizationOut INTEGER
  cdx6500frdcepCharInTotal Counter
  cdx6500frdcepCharOutTotal Counter
  cdx6500frdcepCharsInPerSec INTEGER
  cdx6500frdcepCharsOutPerSec INTEGER
  cdx6500frdcepFrameInTotal Counter
  cdx6500frdcepFrameOutTotal Counter
  cdx6500frdcepFramesInPerSec INTEGER
  cdx6500frdcepFramesOutPerSec INTEGER
  cdx6500frdcepOverrunErrors Counter16
  cdx6500frdcepUnderrunErrors Counter16
  cdx6500frdcepCRCErrors Counter16

Cdx6500SPCTFRDCEStationEntry  
SEQUENCE    
  cdx6500frdcesCfgPortNum INTEGER
  cdx6500frdcesCfgDLCI INTEGER
  cdx6500frdcesAutocallMnem DisplayString
  cdx6500frdcesAutocallTimeout INTEGER
  cdx6500frdcesMaxAutocalls INTEGER
  cdx6500frdcesRemoteConnID INTEGER
  cdx6500frdcesPriority INTEGER
  cdx6500frdcesBillingRecords INTEGER
  cdx6500frdcesStationNum INTEGER
  cdx6500frdcesMaxInboundQueue INTEGER

Cdx6500SPSTFRDCEStationEntry  
SEQUENCE    
  cdx6500frdcesStatsPortNum INTEGER
  cdx6500frdcesStatsDLCI INTEGER
  cdx6500frdcesUtilizationIn INTEGER
  cdx6500frdcesUtilizationOut INTEGER
  cdx6500frdcesMaxSVCCount INTEGER
  cdx6500frdcesCurrentSVCCount INTEGER
  cdx6500frdcesCharInTotal Counter
  cdx6500frdcesCharOutTotal Counter
  cdx6500frdcesCharsInPerSec INTEGER
  cdx6500frdcesCharsOutPerSec INTEGER
  cdx6500frdcesPktInTotal Counter
  cdx6500frdcesPktOutTotal Counter
  cdx6500frdcesPktsInPerSec INTEGER
  cdx6500frdcesPktsOutPerSec INTEGER
  cdx6500frdcesPacketsQueued INTEGER
  cdx6500frdcesFrameInTotal Counter
  cdx6500frdcesFrameOutTotal Counter
  cdx6500frdcesFramesInPerSec INTEGER
  cdx6500frdcesFramesOutPerSec INTEGER
  cdx6500frdcesInfoFramesIn Counter
  cdx6500frdcesInfoFramesOut Counter
  cdx6500frdcesRNRFramesIn Counter
  cdx6500frdcesRNRFramesOut Counter
  cdx6500frdcesRRFramesIn Counter
  cdx6500frdcesRRFramesOut Counter
  cdx6500frdcesREJFramesIn Counter
  cdx6500frdcesREJFramesOut Counter
  cdx6500frdcesDataPktsIn Counter
  cdx6500frdcesDataPktsOut Counter
  cdx6500frdcesResetStats INTEGER
  cdx6500frdcesBoot INTEGER
  cdx6500frdcesDisable INTEGER
  cdx6500frdcesEnable INTEGER

Cdx6500frdcepPContEntry  
SEQUENCE    
  cdx6500frdcepContPortNumber INTEGER
  cdx6500frdcepContPortControl INTEGER

Cdx6500frdcesSContEntry  
SEQUENCE    
  cdx6500frdcesStationPortNumber INTEGER
  cdx6500frdcesStationDLCI INTEGER
  cdx6500frdcesStationControl INTEGER

Defined Values

codex 1.3.6.1.4.1.449
OBJECT IDENTIFIER    

cdxProductSpecific 1.3.6.1.4.1.449.2
OBJECT IDENTIFIER    

cdx6500 1.3.6.1.4.1.449.2.1
OBJECT IDENTIFIER    

cdx6500Configuration 1.3.6.1.4.1.449.2.1.2
OBJECT IDENTIFIER    

cdx6500CfgProtocolGroup 1.3.6.1.4.1.449.2.1.2.1
OBJECT IDENTIFIER    

cdx6500PCTPortProtocolGroup 1.3.6.1.4.1.449.2.1.2.1.1
OBJECT IDENTIFIER    

cdx6500PCTStationProtocolGroup 1.3.6.1.4.1.449.2.1.2.1.3
OBJECT IDENTIFIER    

cdx6500Statistics 1.3.6.1.4.1.449.2.1.3
OBJECT IDENTIFIER    

cdx6500StatProtocolGroup 1.3.6.1.4.1.449.2.1.3.1
OBJECT IDENTIFIER    

cdx6500PSTPortProtocolGroup 1.3.6.1.4.1.449.2.1.3.1.1
OBJECT IDENTIFIER    

cdx6500PSTStationProtocolGroup 1.3.6.1.4.1.449.2.1.3.1.3
OBJECT IDENTIFIER    

cdx6500Controls 1.3.6.1.4.1.449.2.1.4
OBJECT IDENTIFIER    

cdx6500PCTFRDCEPortTable 1.3.6.1.4.1.449.2.1.2.1.1.6
All of the configuration parameters relevant to the Frame Relay DCE Port table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Cdx6500PCTFRDCEPortEntry

cdx6500PCTFRDCEPortEntry 1.3.6.1.4.1.449.2.1.2.1.1.6.1
A row of SDLC Port configuration parameters.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Cdx6500PCTFRDCEPortEntry  

cdx6500frdcepCfgPortNum 1.3.6.1.4.1.449.2.1.2.1.1.6.1.1
Port Number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..54  

cdx6500frdcepConnectionType 1.3.6.1.4.1.449.2.1.2.1.1.6.1.2
Specify the control signal handshake and clocking required for a connection to be made to this port: simp - simple, no control signals required. newvalSimp - same functionality as 'simp', new enumeration added for RFC1155 compatibility.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER simp(0), newvalSimp(50)  

cdx6500frdcepClockSource 1.3.6.1.4.1.449.2.1.2.1.1.6.1.3
int - internal clock source. ext - external clock source. extint - Internal receive and external transmit clock source (DCE only). extlp - external receive and loopback transmit clock source (DTE only). EXTLP must be configured in conjunction with EXTINT. newvalInt - same functionality as 'int', new enumeration added for RFC1155 compatibility.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER int(0), ext(1), extint(2), extlp(3), newvalInt(50)  

cdx6500frdcepClockSpeed 1.3.6.1.4.1.449.2.1.2.1.1.6.1.4
This is the speed of the port in bits per second, when using internal clocking. Note that the maximum port speed is dependent on the type of hardware installed. Consult the users manual for details.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1200..2048000  

cdx6500frdcepMaxStations 1.3.6.1.4.1.449.2.1.2.1.1.6.1.5
The highest station number to be configured on this FRA port. It is used to limit the configuration of stations.
Status: deprecated Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500frdcepCtrlProtocol 1.3.6.1.4.1.449.2.1.2.1.1.6.1.6
Whether ANSI T1.617 Annex D or LMI Support is enabled none - None is enabled. annexD - Annex D is enabled. lmi - LMI is enabled. annexA - Annex A is enabled. newvalAnnexD - same functionality as 'annexD', new enumeration added for RFC1155 compatibility.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER annexD(0), none(1), lmi(2), annexA(3), newvalAnnexD(50)  

cdx6500frdcepT391 1.3.6.1.4.1.449.2.1.2.1.1.6.1.7
This parameter is the Link Integrity Verification Timer polling period. When operating in bi-directional mode, FRA port sends status enquiry messages to network every T391/nT1 seconds.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500frdcepT392 1.3.6.1.4.1.449.2.1.2.1.1.6.1.8
This parameter is the Polling Cycle Verification Timer priod. The FRA port expects status enquiry messages every T392/nT2 seconds. This parameter must be set to a value greater than N391/nT1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500frdcepN391 1.3.6.1.4.1.449.2.1.2.1.1.6.1.9
This parameter is the Full Status Polling Cycle count. When operating in bi-directional mode, the FRA port sends Full status enquiry messages to network every N391/nN1 polls.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500frdcepN392 1.3.6.1.4.1.449.2.1.2.1.1.6.1.10
This parameter is the Error Inactivity Threshold. The data link is declared to be up after receiving N392/nN2 consecutive events without error. The data link is declared to be down when any N392/nN2 of the previous N393/nN3 events were received in error. This parameter must be set to a value less than or equal to N393/nN3.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500frdcepN393 1.3.6.1.4.1.449.2.1.2.1.1.6.1.11
This parameter is the Monitored Events Count for measuring N392. The data link is declared to be down when any N392/nN2 of the previous N393/nN3 events were received in error. This parameter must be set to a value greater than or equal to N392/nN2.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500frdcepNT1 1.3.6.1.4.1.449.2.1.2.1.1.6.1.12
This parameter is the Link Integrity Verification Timer polling period. When operating in bi-directional mode, FRA port sends status enquiry messages to network every T391/nT1 seconds.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500frdcepNT2 1.3.6.1.4.1.449.2.1.2.1.1.6.1.13
This parameter is the Polling Cycle Verification Timer priod. The FRA port expects status enquiry messages every T392/nT2 seconds. This parameter must be set to a value greater than N391/nT1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500frdcepNN1 1.3.6.1.4.1.449.2.1.2.1.1.6.1.14
This parameter is the Full Status Polling Cycle count. When operating in bi-directional mode, the FRA port sends Full status enquiry messages to network every N391/nN1 polls.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500frdcepNN2 1.3.6.1.4.1.449.2.1.2.1.1.6.1.15
This parameter is the Error Inactivity Threshold. The data link is declared to be up after receiving N392/nN2 consecutive events without error. The data link is declared to be down when any N392/nN2 of the previous N393/nN3 events were received in error. This parameter must be set to a value less than or equal to N393/nN3.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500frdcepNN3 1.3.6.1.4.1.449.2.1.2.1.1.6.1.16
This parameter is the Monitored Events Count for measuring N392. The data link is declared to be down when any N392/nN2 of the previous N393/nN3 events were received in error. This parameter must be set to a value greater than or equal to N392/nN2.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500frdcepSubaddress 1.3.6.1.4.1.449.2.1.2.1.1.6.1.17
Calls addressed to this node and with this subaddress will be routed to this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..3)  

cdx6500frdcepBiDirAnnexD 1.3.6.1.4.1.449.2.1.2.1.1.6.1.18
Whether ANSI T1.617 Annex D bi-directional procedures are enabled bi - Bi-directional procedures are enabled. uni - Uni-directional procedures are enabled. newvalBi - same functionality as 'bi', new enumeration added for RFC1155 compatibility.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER bi(0), uni(1), newvalBi(50)  

cdx6500frdcepInvertTXClock 1.3.6.1.4.1.449.2.1.2.1.1.6.1.19
This parameter specifies whether the phase of the transmit clock should be inverted. Note: This parameter is primarily for X.21 electrical interfaces. no - Don't invert. yes - Invert.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER no(1), yes(2), nc(100)  

cdx6500frdcepControlProtocolOptions 1.3.6.1.4.1.449.2.1.2.1.1.6.1.20
These options control the PVC management protocol none - No option selected async - The port will send/receive asynchronous A-bit if it is performing Network side protocol functionality nbit - The port will send and accept N-bit messages dbit - The port will send and accept D-bit messages This forces ASYNC to be specified (dbit+async)
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..16)  

cdx6500frdcepDiscardControlOptions 1.3.6.1.4.1.449.2.1.2.1.1.6.1.21
This parameter controls the discard frame options none - No option selected debit - DE marked frames are discarded before non-DE frames
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER none(1), debit(2)  

cdx6500frdcepElectricalInterfaceType 1.3.6.1.4.1.449.2.1.2.1.1.6.1.22
Specify the Electrical Interface Type: V.24 - V.24 Electrical Interface Type V.35 - V.35 Electrical Interface Type V.36 - V.36 Electrical Interface Type X.21 - X.21 Electrical Interface Type NONE - Electrically disabled
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER v24(1), v35(2), v36(3), x21(4), none(5)  

cdx6500frdcepV24ElectricalInterfaceOption 1.3.6.1.4.1.449.2.1.2.1.1.6.1.23
Specify the Pin 22 option: RI - V.24 uses Pin 22 for Ring Indicator output signal TM - V.24 uses Pin 22 for Test Mode input signal
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ri(1), tm(2)  

cdx6500frdcepHighSpeedElectricalInterfaceOption 1.3.6.1.4.1.449.2.1.2.1.1.6.1.24
Specify the cable type: NONE - V.35/V.36/X.21 DCE with straight through cable XOVER - V.35/V.36/X.21 DCE with crossover adapter cable
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER none(1), xover(2)  

cdx6500PPSTFRDCEPortTable 1.3.6.1.4.1.449.2.1.3.1.1.6
All of the statistics parameters relevant to the Frame Relay DCE Port table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Cdx6500PPSTFRDCEPortEntry

cdx6500PPSTFRDCEPortEntry 1.3.6.1.4.1.449.2.1.3.1.1.6.1
A row of Frame Relay DCE Port statistics parameters.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Cdx6500PPSTFRDCEPortEntry  

cdx6500frdcepStatsPortNum 1.3.6.1.4.1.449.2.1.3.1.1.6.1.1
Port Number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..54  

cdx6500frdcepPortStatus 1.3.6.1.4.1.449.2.1.3.1.1.6.1.2
Port Status indicates whether or not the port is switched on and is ready for operation. This value may be one of : up - Port is up and running. down - Port is down. disabled - Port has been disabled. enabled - port has been enabled, but is not yet Up. busyOut - port has been set to be disabled as soon as last active call is disestablished. No new calls will be established. newvalDisabled - same functionality as 'disabled', new enumeration added for RFC1155 compatibility.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1), busyOut(2), up(3), down(4), newvalDisabled(50)  

cdx6500frdcepPortSpeed 1.3.6.1.4.1.449.2.1.3.1.1.6.1.3
This is the speed of the port if clock is internal. If clock is external, this is the detected clock speed. If Port Speed is 0, clock is external, but clocking is not being received from attatched device.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500frdcepUtilizationIn 1.3.6.1.4.1.449.2.1.3.1.1.6.1.4
Pertcentage of Port input bandwidth in use.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

cdx6500frdcepUtilizationOut 1.3.6.1.4.1.449.2.1.3.1.1.6.1.5
Pertcentage of Port output bandwidth in use.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

cdx6500frdcepCharInTotal 1.3.6.1.4.1.449.2.1.3.1.1.6.1.6
Number of message received since last node, port, or statistics reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500frdcepCharOutTotal 1.3.6.1.4.1.449.2.1.3.1.1.6.1.7
Number of message sent since last node, port, or statistics reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500frdcepCharsInPerSec 1.3.6.1.4.1.449.2.1.3.1.1.6.1.8
Number of characters received per second.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500frdcepCharsOutPerSec 1.3.6.1.4.1.449.2.1.3.1.1.6.1.9
Number of characters received per second.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500frdcepFrameInTotal 1.3.6.1.4.1.449.2.1.3.1.1.6.1.10
Number of frames received since last node, port, or statistics reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500frdcepFrameOutTotal 1.3.6.1.4.1.449.2.1.3.1.1.6.1.11
Number of frames sent since last node, port, or statistics reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500frdcepFramesInPerSec 1.3.6.1.4.1.449.2.1.3.1.1.6.1.12
Average number of frames received per second during the previous minute
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500frdcepFramesOutPerSec 1.3.6.1.4.1.449.2.1.3.1.1.6.1.13
Average number of frames transmitted per second during the previous minute
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500frdcepOverrunErrors 1.3.6.1.4.1.449.2.1.3.1.1.6.1.14
Total number of overrun errors counted by the I/O driver.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter16  

cdx6500frdcepUnderrunErrors 1.3.6.1.4.1.449.2.1.3.1.1.6.1.15
Total number of underrun errors counted by the I/O driver.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter16  

cdx6500frdcepCRCErrors 1.3.6.1.4.1.449.2.1.3.1.1.6.1.16
Total number of CRC errors counted by the I/O driver.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter16  

cdx6500SPCTFRDCEStationTable 1.3.6.1.4.1.449.2.1.2.1.3.3
All of the configuration parameters relevant to the Frame Relay DCE Station table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Cdx6500SPCTFRDCEStationEntry

cdx6500SPCTFRDCEStationEntry 1.3.6.1.4.1.449.2.1.2.1.3.3.1
A row of Frame Relay DCE station configuration parameters.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Cdx6500SPCTFRDCEStationEntry  

cdx6500frdcesCfgPortNum 1.3.6.1.4.1.449.2.1.2.1.3.3.1.1
Station number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..54  

cdx6500frdcesCfgDLCI 1.3.6.1.4.1.449.2.1.2.1.3.3.1.2
The Data Link Connection Identifier (dlci) is the unique identifier for the station on the FRA Port. Its valid range is 16 - 1007. It must match the DLCI configured on the attached FRAD.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 16..1007  

cdx6500frdcesAutocallMnem 1.3.6.1.4.1.449.2.1.2.1.3.3.1.3
This is the mnemonic name used for auto calling. A blank indicates auto calling is disabled.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..8)  

cdx6500frdcesAutocallTimeout 1.3.6.1.4.1.449.2.1.2.1.3.3.1.4
This is the time interval in seconds between call attempts when auto calling.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500frdcesMaxAutocalls 1.3.6.1.4.1.449.2.1.2.1.3.3.1.5
This parameter is used to specify the number of times that this FRA station will attempt to call when auto calling is enabled. A value of zero will allow unlimited attempts.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500frdcesRemoteConnID 1.3.6.1.4.1.449.2.1.2.1.3.3.1.6
This parameter specifies the number of the remote LAN Connection or the number of the remote FRA station that this FRA station will attempt to connect to if configured for autocall.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500frdcesPriority 1.3.6.1.4.1.449.2.1.2.1.3.3.1.7
This parameter specifies the Traffic Priority of this FRA station. newvalLow - same functionality as 'low', new enumeration added for RFC1155 compatibility.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER low(0), medium(1), high(2), expedite(3), newvalLow(50)  

cdx6500frdcesBillingRecords 1.3.6.1.4.1.449.2.1.2.1.3.3.1.8
This controls whether billing (accounting) records will be created for calls on this FRA station. newvalDisabled : same functionality as 'disabled', new enumeration added for RFC1155 compliance.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1), newvalDisabled(50)  

cdx6500frdcesStationNum 1.3.6.1.4.1.449.2.1.2.1.3.3.1.9
The number of the logical link on the line. This is the value of Sxx for routing purposes.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500frdcesMaxInboundQueue 1.3.6.1.4.1.449.2.1.2.1.3.3.1.10
This specifies the maximum number of frames which may be queued in the station's inbound queue. A smaller value may be choosen for applications which experience objectionable delays, if due to excessive growth of the station's inbound queue.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 100..2500  

cdx6500SPSTFRDCEStationTable 1.3.6.1.4.1.449.2.1.3.1.3.3
All of the statistics parameters relevant to the Frame Relay DCE Station (DLCI) table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Cdx6500SPSTFRDCEStationEntry

cdx6500SPSTFRDCEStationEntry 1.3.6.1.4.1.449.2.1.3.1.3.3.1
A row of Frame Relay DCE station (DLCI) Statistics parameters.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Cdx6500SPSTFRDCEStationEntry  

cdx6500frdcesStatsPortNum 1.3.6.1.4.1.449.2.1.3.1.3.3.1.1
Port Number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..54  

cdx6500frdcesStatsDLCI 1.3.6.1.4.1.449.2.1.3.1.3.3.1.2
The Data Link Connection Identifier (dlci) is the unique identifier for the station on the FRA Port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 16..1007  

cdx6500frdcesUtilizationIn 1.3.6.1.4.1.449.2.1.3.1.3.3.1.3
The quantity of user bytes received on the line as a percentage of the maximum number of bytes that could have been received.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

cdx6500frdcesUtilizationOut 1.3.6.1.4.1.449.2.1.3.1.3.3.1.4
The quantity of user bytes sent on the line as a percentage of the maximum number of bytes that could have been received.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

cdx6500frdcesMaxSVCCount 1.3.6.1.4.1.449.2.1.3.1.3.3.1.5
Maximum number of SVCs available in the network.
Status: deprecated Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500frdcesCurrentSVCCount 1.3.6.1.4.1.449.2.1.3.1.3.3.1.6
Number of SVCs currently in use.
Status: deprecated Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500frdcesCharInTotal 1.3.6.1.4.1.449.2.1.3.1.3.3.1.7
Total number of characters received since last node, port, or station boot or statistics reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500frdcesCharOutTotal 1.3.6.1.4.1.449.2.1.3.1.3.3.1.8
Total number of characters sent since last node, port, or station boot or statistics reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500frdcesCharsInPerSec 1.3.6.1.4.1.449.2.1.3.1.3.3.1.9
Average number of characters received per second.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500frdcesCharsOutPerSec 1.3.6.1.4.1.449.2.1.3.1.3.3.1.10
Average number of characters transmitted per second.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500frdcesPktInTotal 1.3.6.1.4.1.449.2.1.3.1.3.3.1.11
Total number of Packets received since last node, port, or station boot or statistics reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500frdcesPktOutTotal 1.3.6.1.4.1.449.2.1.3.1.3.3.1.12
Total number of Packets sent since last node, port, or station boot or statistics reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500frdcesPktsInPerSec 1.3.6.1.4.1.449.2.1.3.1.3.3.1.13
Average number of Packets received per second.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500frdcesPktsOutPerSec 1.3.6.1.4.1.449.2.1.3.1.3.3.1.14
Average number of Packets transmitted per second.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500frdcesPacketsQueued 1.3.6.1.4.1.449.2.1.3.1.3.3.1.15
Current number of packets buffered since since last node, port, or station boot or statistics reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500frdcesFrameInTotal 1.3.6.1.4.1.449.2.1.3.1.3.3.1.16
Total number of frames received since last node, port, or station boot or statistics reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500frdcesFrameOutTotal 1.3.6.1.4.1.449.2.1.3.1.3.3.1.17
Total number of frames sent since last node, port, or station boot or statistics reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500frdcesFramesInPerSec 1.3.6.1.4.1.449.2.1.3.1.3.3.1.18
Average number of frames received per second.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500frdcesFramesOutPerSec 1.3.6.1.4.1.449.2.1.3.1.3.3.1.19
Average number of frames transmitted per second.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cdx6500frdcesInfoFramesIn 1.3.6.1.4.1.449.2.1.3.1.3.3.1.20
Number of data frames received since last node, port, or station boot or statistics reset.
Status: deprecated Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500frdcesInfoFramesOut 1.3.6.1.4.1.449.2.1.3.1.3.3.1.21
Number of data frames sent since last node, port, or station boot or statistics reset.
Status: deprecated Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500frdcesRNRFramesIn 1.3.6.1.4.1.449.2.1.3.1.3.3.1.22
Number of RNR frames received since last node, port, or station boot or statistics reset.
Status: deprecated Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500frdcesRNRFramesOut 1.3.6.1.4.1.449.2.1.3.1.3.3.1.23
Number of RNR frames sent since last node, port, or station boot or statistics reset.
Status: deprecated Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500frdcesRRFramesIn 1.3.6.1.4.1.449.2.1.3.1.3.3.1.24
Number of RR frames received since last node, port, or station boot or statistics reset.
Status: deprecated Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500frdcesRRFramesOut 1.3.6.1.4.1.449.2.1.3.1.3.3.1.25
Number of RR frames sent since last node, port, or station boot or statistics reset.
Status: deprecated Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500frdcesREJFramesIn 1.3.6.1.4.1.449.2.1.3.1.3.3.1.26
Number of REJ frames received since last node, port, or station boot or statistics reset.
Status: deprecated Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500frdcesREJFramesOut 1.3.6.1.4.1.449.2.1.3.1.3.3.1.27
Number of REJ frames sent since last node, port, or station boot or statistics reset.
Status: deprecated Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500frdcesDataPktsIn 1.3.6.1.4.1.449.2.1.3.1.3.3.1.28
Number of data packets received since last node, port, or station boot or statistics reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500frdcesDataPktsOut 1.3.6.1.4.1.449.2.1.3.1.3.3.1.29
Number of data packets sent since last node, port, or station boot or statistics reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cdx6500frdcesResetStats 1.3.6.1.4.1.449.2.1.3.1.3.3.1.30
reset : Resets the specified Frame Relay station statistics. noReset : Do not reset the specified Frame Relay station statistics.
Status: obsolete Access: write-only
OBJECT-TYPE    
  INTEGER reset(1), noReset(2)  

cdx6500frdcesBoot 1.3.6.1.4.1.449.2.1.3.1.3.3.1.31
boot : Boots the specified Frame Relay station. noBoot : Do not boot the specified Frame Relay station.
Status: obsolete Access: write-only
OBJECT-TYPE    
  INTEGER boot(1), noBoot(2)  

cdx6500frdcesDisable 1.3.6.1.4.1.449.2.1.3.1.3.3.1.32
disable : Disables the specified Frame Relay station. noDisable : Do not disable the specified Frame Relay station.
Status: obsolete Access: write-only
OBJECT-TYPE    
  INTEGER disable(1), noDisable(2)  

cdx6500frdcesEnable 1.3.6.1.4.1.449.2.1.3.1.3.3.1.33
enable : Enable the specified Frame Relay station. noEnable : Do not enable the specified Frame Relay station.
Status: obsolete Access: write-only
OBJECT-TYPE    
  INTEGER enable(1), noEnable(2)  

cdx6500ContFRATable 1.3.6.1.4.1.449.2.1.4.17
OBJECT IDENTIFIER    

cdx6500frdcepPContTable 1.3.6.1.4.1.449.2.1.4.17.1
Control parameters for FRA ports.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Cdx6500frdcepPContEntry

cdx6500frdcepPContEntry 1.3.6.1.4.1.449.2.1.4.17.1.1
A row of FRA port control.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Cdx6500frdcepPContEntry  

cdx6500frdcepContPortNumber 1.3.6.1.4.1.449.2.1.4.17.1.1.1
Port number of the FRA port.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..255  

cdx6500frdcepContPortControl 1.3.6.1.4.1.449.2.1.4.17.1.1.2
Control operations for the specified FRA port. boot - Boots the FRA port enable - Enables the FRA port disable - Disables the FRA port resetstats - Resets the FRA port statistics.
Status: mandatory Access: write-only
OBJECT-TYPE    
  INTEGER boot(1), enable(2), disable(3), resetstats(4)  

cdx6500frdcesSContTable 1.3.6.1.4.1.449.2.1.4.17.2
Control parameter for Fra stations
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    Cdx6500frdcesSContEntry

cdx6500frdcesSContEntry 1.3.6.1.4.1.449.2.1.4.17.2.1
A row of FRA Station control
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  Cdx6500frdcesSContEntry  

cdx6500frdcesStationPortNumber 1.3.6.1.4.1.449.2.1.4.17.2.1.1
Fra Station Port number
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..255  

cdx6500frdcesStationDLCI 1.3.6.1.4.1.449.2.1.4.17.2.1.2
Fra Station DLCI number
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  INTEGER 16..1007  

cdx6500frdcesStationControl 1.3.6.1.4.1.449.2.1.4.17.2.1.3
Control operations for the specified FRA station. boot - Boot the FRA station enable - Enables the FRA station disable - Disables the FRA station resetstats - Resets the FRA station statistics.
Status: mandatory Access: write-only
OBJECT-TYPE    