FCMGMT-MIB

File: FCMGMT-MIB.mib (113401 bytes)

Imported modules

RFC1155-SMI RFC-1212 RFC1213-MIB
RFC-1215

Imported symbols

IpAddress TimeTicks experimental
OBJECT-TYPE DisplayString TRAP-TYPE

Defined Types

FcNameId  
OCTET STRING Size(8)    

FcGlobalId  
OCTET STRING Size(16)    

FcAddressId  
OCTET STRING Size(3)    

FcEventSeverity  
INTEGER unknown(1), emergency(2), alert(3), critical(4), error(5), warning(6), notify(7), info(8), debug(9), mark(10)    

FcUnitType  
INTEGER unknown(1), other(2), hub(3), switch(4), gateway(5), converter(6), hba(7), proxy-agent(8), storage-device(9), host(10), storage-subsystem(11), module(12), swdriver(13), storage-access-device(14), wdm(15), ups(16)    

ConnUnitEntry  
SEQUENCE    
  connUnitId FcGlobalId
  connUnitGlobalId FcGlobalId
  connUnitType FcUnitType
  connUnitNumports INTEGER
  connUnitState INTEGER
  connUnitStatus INTEGER
  connUnitProduct DisplayString
  connUnitSn DisplayString
  connUnitUpTime TimeTicks
  connUnitUrl DisplayString
  connUnitDomainId OCTET STRING
  connUnitProxyMaster INTEGER
  connUnitPrincipal INTEGER
  connUnitNumSensors INTEGER
  connUnitStatusChangeTime TimeTicks
  connUnitConfigurationChangeTime TimeTicks
  connUnitNumRevs INTEGER
  connUnitNumZones INTEGER
  connUnitModuleId FcGlobalId
  connUnitName DisplayString
  connUnitInfo DisplayString
  connUnitControl INTEGER
  connUnitContact DisplayString
  connUnitLocation DisplayString
  connUnitEventFilter FcEventSeverity
  connUnitNumEvents INTEGER
  connUnitMaxEvents INTEGER
  connUnitEventCurrID INTEGER

ConnUnitRevsEntry  
SEQUENCE    
  connUnitRevsUnitId FcGlobalId
  connUnitRevsIndex INTEGER
  connUnitRevsRevId DisplayString
  connUnitRevsDescription DisplayString

ConnUnitSensorEntry  
SEQUENCE    
  connUnitSensorUnitId FcGlobalId
  connUnitSensorIndex INTEGER 1..2147483647
  connUnitSensorName DisplayString
  connUnitSensorStatus INTEGER
  connUnitSensorInfo DisplayString
  connUnitSensorMessage DisplayString
  connUnitSensorType INTEGER
  connUnitSensorCharacteristic INTEGER

ConnUnitPortEntry  
SEQUENCE    
  connUnitPortUnitId FcGlobalId
  connUnitPortIndex INTEGER
  connUnitPortType INTEGER
  connUnitPortFCClassCap OCTET STRING
  connUnitPortFCClassOp OCTET STRING
  connUnitPortState INTEGER
  connUnitPortStatus INTEGER
  connUnitPortTransmitterType INTEGER
  connUnitPortModuleType INTEGER
  connUnitPortWwn FcNameId
  connUnitPortFCId FcAddressId
  connUnitPortSn DisplayString
  connUnitPortRevision DisplayString
  connUnitPortVendor DisplayString
  connUnitPortSpeed INTEGER
  connUnitPortControl INTEGER
  connUnitPortName DisplayString
  connUnitPortPhysicalNumber INTEGER
  connUnitPortStatObject OBJECT IDENTIFIER
  connUnitPortProtocolCap OCTET STRING
  connUnitPortProtocolOp OCTET STRING
  connUnitPortNodeWwn FcNameId
  connUnitPortHWState INTEGER

ConnUnitEventEntry  
SEQUENCE    
  connUnitEventUnitId FcGlobalId
  connUnitEventIndex INTEGER 1..2147483647
  connUnitEventId INTEGER
  connUnitREventTime DisplayString
  connUnitSEventTime TimeTicks
  connUnitEventSeverity FcEventSeverity
  connUnitEventType INTEGER
  connUnitEventObject OBJECT IDENTIFIER
  connUnitEventDescr DisplayString

ConnUnitLinkEntry  
SEQUENCE    
  connUnitLinkUnitId FcGlobalId
  connUnitLinkIndex INTEGER
  connUnitLinkNodeIdX OCTET STRING
  connUnitLinkPortNumberX INTEGER
  connUnitLinkPortWwnX FcGlobalId
  connUnitLinkNodeIdY OCTET STRING
  connUnitLinkPortNumberY INTEGER
  connUnitLinkPortWwnY FcGlobalId
  connUnitLinkAgentAddressY OCTET STRING
  connUnitLinkAgentAddressTypeY INTEGER
  connUnitLinkAgentPortY INTEGER
  connUnitLinkUnitTypeY FcUnitType
  connUnitLinkConnIdY OCTET STRING
  connUnitLinkCurrIndex INTEGER

ConnUnitPortStatEntry  
SEQUENCE    
  connUnitPortStatUnitId FcGlobalId
  connUnitPortStatIndex INTEGER
  connUnitPortStatCountError OCTET STRING
  connUnitPortStatCountTxObjects OCTET STRING
  connUnitPortStatCountRxObjects OCTET STRING
  connUnitPortStatCountTxElements OCTET STRING
  connUnitPortStatCountRxElements OCTET STRING
  connUnitPortStatCountBBCreditZero OCTET STRING
  connUnitPortStatCountInputBuffersFull OCTET STRING
  connUnitPortStatCountFBSYFrames OCTET STRING
  connUnitPortStatCountPBSYFrames OCTET STRING
  connUnitPortStatCountFRJTFrames OCTET STRING
  connUnitPortStatCountPRJTFrames OCTET STRING
  connUnitPortStatCountClass1RxFrames OCTET STRING
  connUnitPortStatCountClass1TxFrames OCTET STRING
  connUnitPortStatCountClass1FBSYFrames OCTET STRING
  connUnitPortStatCountClass1PBSYFrames OCTET STRING
  connUnitPortStatCountClass1FRJTFrames OCTET STRING
  connUnitPortStatCountClass1PRJTFrames OCTET STRING
  connUnitPortStatCountClass2RxFrames OCTET STRING
  connUnitPortStatCountClass2TxFrames OCTET STRING
  connUnitPortStatCountClass2FBSYFrames OCTET STRING
  connUnitPortStatCountClass2PBSYFrames OCTET STRING
  connUnitPortStatCountClass2FRJTFrames OCTET STRING
  connUnitPortStatCountClass2PRJTFrames OCTET STRING
  connUnitPortStatCountClass3RxFrames OCTET STRING
  connUnitPortStatCountClass3TxFrames OCTET STRING
  connUnitPortStatCountClass3Discards OCTET STRING
  connUnitPortStatCountRxMulticastObjects OCTET STRING
  connUnitPortStatCountTxMulticastObjects OCTET STRING
  connUnitPortStatCountRxBroadcastObjects OCTET STRING
  connUnitPortStatCountTxBroadcastObjects OCTET STRING
  connUnitPortStatCountRxLinkResets OCTET STRING
  connUnitPortStatCountTxLinkResets OCTET STRING
  connUnitPortStatCountNumberLinkResets OCTET STRING
  connUnitPortStatCountRxOfflineSequences OCTET STRING
  connUnitPortStatCountTxOfflineSequences OCTET STRING
  connUnitPortStatCountNumberOfflineSequences OCTET STRING
  connUnitPortStatCountLinkFailures OCTET STRING
  connUnitPortStatCountInvalidCRC OCTET STRING
  connUnitPortStatCountInvalidTxWords OCTET STRING
  connUnitPortStatCountPrimitiveSequenceProtocolErrors OCTET STRING
  connUnitPortStatCountLossofSignal OCTET STRING
  connUnitPortStatCountLossofSynchronization OCTET STRING
  connUnitPortStatCountInvalidOrderedSets OCTET STRING
  connUnitPortStatCountFramesTooLong OCTET STRING
  connUnitPortStatCountFramesTruncated OCTET STRING
  connUnitPortStatCountAddressErrors OCTET STRING
  connUnitPortStatCountDelimiterErrors OCTET STRING
  connUnitPortStatCountEncodingDisparityErrors OCTET STRING

ConnUnitSnsEntry  
SEQUENCE    
  connUnitSnsId OCTET STRING
  connUnitSnsPortIndex INTEGER
  connUnitSnsPortIdentifier FcAddressId
  connUnitSnsPortName FcNameId
  connUnitSnsNodeName FcNameId
  connUnitSnsClassOfSvc OCTET STRING
  connUnitSnsNodeIPAddress OCTET STRING
  connUnitSnsProcAssoc OCTET STRING
  connUnitSnsFC4Type OCTET STRING
  connUnitSnsPortType OCTET STRING
  connUnitSnsPortIPAddress OCTET STRING
  connUnitSnsFabricPortName FcNameId
  connUnitSnsHardAddress FcAddressId
  connUnitSnsSymbolicPortName DisplayString
  connUnitSnsSymbolicNodeName DisplayString

TrapRegEntry  
SEQUENCE    
  trapRegIpAddress IpAddress
  trapRegPort INTEGER 1..2147483647
  trapRegFilter FcEventSeverity
  trapRegRowState INTEGER

Defined Values

fcmgmt 1.3.6.1.3.94
OBJECT IDENTIFIER    

connSet 1.3.6.1.3.94.1
OBJECT IDENTIFIER    

trapReg 1.3.6.1.3.94.2
OBJECT IDENTIFIER    

statSet 1.3.6.1.3.94.4
OBJECT IDENTIFIER    

connUnitServiceSet 1.3.6.1.3.94.5
OBJECT IDENTIFIER    

connUnitServiceScalars 1.3.6.1.3.94.5.1
OBJECT IDENTIFIER    

connUnitServiceTables 1.3.6.1.3.94.5.2
OBJECT IDENTIFIER    

revisionNumber 1.3.6.1.3.94.3
This is the revision number for this MIB. The format of the revision value is as follows (0) = high order major revision number (1) = low order major revision number (2) = high order minor revision number (3) = low order minor revision number The value will be stored as an ASCII value. The following is the current value of this object. (0) = '0' (1) = '3' (2) = '0' (3) = '0' This defines a revision of 03.00
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(4)  

uNumber 1.3.6.1.3.94.1.1
The number of connectivity units present on this system (represented by this agent). May be a count of the boards in a chassis or the number of full boxes in a rack.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

systemURL 1.3.6.1.3.94.1.2
The top-level URL of the system. If it does not exist the value is empty string. The URL format is implementation dependant and can have keywords embedded that are preceeded by a percent sign (eg, %USER). The following are the defined keywords that will be recognized and replaced with data during a launch. USER - replace with username PASSWORD - replace with password GLOBALID - replace with globalid SERIALNO - replace with serial number If write is not supported, then return invalid. This value will be retained across boots.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

statusChangeTime 1.3.6.1.3.94.1.3
The sysuptime timestamp in centiseconds at which the last status change occurred for any members of the set.
Status: obsolete Access: read-only
OBJECT-TYPE    
  TimeTicks  

configurationChangeTime 1.3.6.1.3.94.1.4
The sysuptime timestamp in centiseconds at which the last configuration change occurred for any members of the set. This represents a union of change information for connUnitConfigurationChangeTime.
Status: obsolete Access: read-only
OBJECT-TYPE    
  TimeTicks  

connUnitTableChangeTime 1.3.6.1.3.94.1.5
The sysuptime timestamp in centiseconds at which the connUnitTable was updated (an entry was either added or deleted.
Status: obsolete Access: read-only
OBJECT-TYPE    
  TimeTicks  

connUnitTable 1.3.6.1.3.94.1.6
A list of units under a single SNMP agent. The number of entries is given by the value of uNumber. It is 1 for stand-alone system.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ConnUnitEntry

connUnitEntry 1.3.6.1.3.94.1.6.1
A connectivity unit entry containing objects for a particular unit.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  ConnUnitEntry  

connUnitId 1.3.6.1.3.94.1.6.1.1
The unique identification for this connectivity unit among those within this proxy domain. The value MUST be unique within the proxy domain because it is the index variable for connUnitTable. The value assigned to a given conectivity unit SHOULD be persistent across agent and unit resets. It SHOULD be the same as connUnitGlobalId if connUnitGlobalId is known and stable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  FcGlobalId  

connUnitGlobalId 1.3.6.1.3.94.1.6.1.2
An optional global-scope identifier for this connectivity unit. It MUST be a WWN for this connectivity unit or 16 octets of value zero. WWN formats requiring fewer than 16 octets MUST be extended to 16 octets with trailing zero octets, Left justified, zero filled, If a WWN is used for connUnitId, the same WWN MUST be used for connUnitGlobalId. When a non-zero value is provided, it SHOULD be persistent across agent and unit resets. It SHOULD be globally unique. It SHOULD be one of these FC-PH/PH3 formats: IEEE (NAA=1) IEEE Extended (NAA=2) IEEE Registered (NAA=5). IEEE Registered extended (NAA=6). Use of the IEEE formats allows any IEEE-registered vendor to assure global uniqueness independently. The following are some references on IEEE WWN formats: http://standards.ieee.org/regauth/oui/tutorials/fibreformat.html http://standards.ieee.org/regauth/oui/tutorials/fibrecomp_id.html If one or more WWNs are associated with the connUnit via other management methods, one of them SHOULD be used for connUnitGlobalId. If there is not a WWN assigned specifically to the connUnit, there is some merit, though not a requirement, to using a WWN assigned to (one of) its permanently attached FC/LAN interface(s). This can not risk uniqueness, though. As a counterexample, if your agent runs in a host and the host has an HBA, it is quite possible that agent, host, and HBA will all be distinct connUnits, so the host and agent can not use the WWN of the HBA. Another example: If your hub has a built-in Ethernet port, it might be reasonable for the hub to use its MAC address (prefixed with the appropriate NAA) as its connUnitId. But if the Ethernet were a replaceable PCCard, the hub should have an independent ID.
Status: mandatory Access: read-only
OBJECT-TYPE    
  FcGlobalId  

connUnitType 1.3.6.1.3.94.1.6.1.3
The type of this connectivity unit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  FcUnitType  

connUnitNumports 1.3.6.1.3.94.1.6.1.4
Number of physical ports in the connectivity unit (internal/embedded, external).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

connUnitState 1.3.6.1.3.94.1.6.1.5
Overall state of the connectivity unit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), online(2), offline(3)  

connUnitStatus 1.3.6.1.3.94.1.6.1.6
Overall status of the connectivity unit. The goal of this object is to be the single poll point to check the status of the connunit. If there is any other component that has warning, then this should be set to warning, etc.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), unused(2), ok(3), warning(4), failed(5)  

connUnitProduct 1.3.6.1.3.94.1.6.1.7
The connectivity unit vendor's product model name.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..79)  

connUnitSn 1.3.6.1.3.94.1.6.1.8
The serial number for this connectivity unit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..79)  

connUnitUpTime 1.3.6.1.3.94.1.6.1.9
The number of centiseconds since the last unit initialization.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

connUnitUrl 1.3.6.1.3.94.1.6.1.10
URL to launch a management application, if applicable. Otherwise empty string. In a standalone unit, this would be the same as the top-level URL. This has the same definition as systemURL for keywords. If write is not supported, then return invalid. This value will be retained across boots.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

connUnitDomainId 1.3.6.1.3.94.1.6.1.11
24 bit Fibre Channel address ID of this connectivity unit, right justified with leading zero's if required. This should be set to the Fibre Channel address ID or if it is a switch it would be set to the Domain Controller address. If this value is not applicable, return all bits set to one.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(3)  

connUnitProxyMaster 1.3.6.1.3.94.1.6.1.12
A value of 'yes' means this is the proxy master unit for a set of managed units. For example, this could be the only unit with a management card in it for a set of units. A standalone unit should return 'yes' for this object.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), no(2), yes(3)  

connUnitPrincipal 1.3.6.1.3.94.1.6.1.13
Whether this connectivity unit is the principal unit within the group of fabric elements. If this value is not applicable, return unknown.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), no(2), yes(3)  

connUnitNumSensors 1.3.6.1.3.94.1.6.1.14
Number of sensors in the connUnitSensorTable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

connUnitStatusChangeTime 1.3.6.1.3.94.1.6.1.15
The sysuptime timestamp in centiseconds at which the last status change occurred.
Status: obsolete Access: read-only
OBJECT-TYPE    
  TimeTicks  

connUnitConfigurationChangeTime 1.3.6.1.3.94.1.6.1.16
The sysuptime timestamp in centiseconds at which the last configuration change occurred.
Status: obsolete Access: read-only
OBJECT-TYPE    
  TimeTicks  

connUnitNumRevs 1.3.6.1.3.94.1.6.1.17
The number of revisions in the connUnitRevsTable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

connUnitNumZones 1.3.6.1.3.94.1.6.1.18
Number of zones defined in connUnitZoneTable.
Status: obsolete Access: read-only
OBJECT-TYPE    
  INTEGER  

connUnitModuleId 1.3.6.1.3.94.1.6.1.19
This is a unique id, persistent between boots, that can be used to group a set of connUnits together into a module. The intended use would be to create a connUnit with a connUnitType of 'module' to represent a physical or logical group of connectivity units. Then the value of the group would be set to the value of connUnitId for this 'container' connUnit. connUnitModuleId should be zeros if this connUnit is not part of a module.
Status: mandatory Access: read-only
OBJECT-TYPE    
  FcGlobalId  

connUnitName 1.3.6.1.3.94.1.6.1.20
A display string containing a name for this connectivity unit. This object value should be persistent between boots.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..79)  

connUnitInfo 1.3.6.1.3.94.1.6.1.21
A display string containing information about this connectivity unit. This object value should be persistent between boots.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

connUnitControl 1.3.6.1.3.94.1.6.1.22
This object is used to control the addressed connUnit. NOTE: 'Cold Start' and 'Warm Start' are as defined in MIB II and are not meant to be a factory reset. resetConnUnitColdStart: the addressed unit performs a 'Cold Start' reset. resetConnUnitWarmStart: the addressed unit performs a 'Warm Start' reset. offlineConnUnit: the addressed unit puts itself into an implementation dependant 'offline' state. In general,if a unit is in an offline state, it cannot be used to perform meaningful Fibre Channel work. onlineConnUnit: the addressed unit puts itself into an implementation dependant 'online' state. In general, if a unit is in an online state, it is capable of performing meaningful Fibre Channel work. NOTE: Each implementation may chose not to allow any or all of these values on a SET.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), invalid(2), resetConnUnitColdStart(3), resetConnUnitWarmStart(4), offlineConnUnit(5), onlineConnUnit(6)  

connUnitContact 1.3.6.1.3.94.1.6.1.23
Contact information for this connectivity unit. Persistent across boots.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..79)  

connUnitLocation 1.3.6.1.3.94.1.6.1.24
Location information for this connectivity unit.Persistent across boots.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..79)  

connUnitEventFilter 1.3.6.1.3.94.1.6.1.25
This value defines the event severity that will be logged by this connectivity unit. All events of severity less than or equal to connUnitEventFilter are logged in connUnitEventTable. Persistent across boots.
Status: mandatory Access: read-write
OBJECT-TYPE    
  FcEventSeverity  

connUnitNumEvents 1.3.6.1.3.94.1.6.1.26
Number of events currently in the connUnitEventTable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

connUnitMaxEvents 1.3.6.1.3.94.1.6.1.27
Max number of events that can be defined in connUnitEventTable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

connUnitEventCurrID 1.3.6.1.3.94.1.6.1.28
The last used event id (connUnitEventIndex).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

connUnitRevsTable 1.3.6.1.3.94.1.7
Table of the revisions supported by connectivity units managed by this agent.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ConnUnitRevsEntry

connUnitRevsEntry 1.3.6.1.3.94.1.7.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  ConnUnitRevsEntry  

connUnitRevsUnitId 1.3.6.1.3.94.1.7.1.1
The connUnitId of the connectivity unit that contains this revision table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  FcGlobalId  

connUnitRevsIndex 1.3.6.1.3.94.1.7.1.2
A unique value among all connUnitRevsEntrys with the same value of connUnitRevsUnitId, in the range between 1 and connUnitNumRevs[connUnitRevsUnitId].
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2147483647  

connUnitRevsRevId 1.3.6.1.3.94.1.7.1.3
A vendor-specific string identifying a revision of a component of the connUnit indexed by connUnitRevsUnitId.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

connUnitRevsDescription 1.3.6.1.3.94.1.7.1.4
Description of a component to which the revision corresponds.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

connUnitSensorTable 1.3.6.1.3.94.1.8
Table of the sensors supported by each connectivity unit managed by this agent.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ConnUnitSensorEntry

connUnitSensorEntry 1.3.6.1.3.94.1.8.1
Each entry contains the information for a specific sensor.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  ConnUnitSensorEntry  

connUnitSensorUnitId 1.3.6.1.3.94.1.8.1.1
The connUnitId of the connectivity unit that contains this sensor table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  FcGlobalId  

connUnitSensorIndex 1.3.6.1.3.94.1.8.1.2
A unique value among all connUnitSensorEntrys with the same value of connUnitSensorUnitId, in the range between 1 and connUnitNumSensor[connUnitSensorUnitId].
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2147483647  

connUnitSensorName 1.3.6.1.3.94.1.8.1.3
A textual identification of the sensor intended primarily for operator use.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

connUnitSensorStatus 1.3.6.1.3.94.1.8.1.4
The status indicated by the sensor.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), other(2), ok(3), warning(4), failed(5)  

connUnitSensorInfo 1.3.6.1.3.94.1.8.1.5
Miscellaneous static info about the sensor such as its serial number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

connUnitSensorMessage 1.3.6.1.3.94.1.8.1.6
This describes the status of the sensor as a message. It may also provide more resolution on the sensor indication, for example 'Cover temperature 1503K, above nominal operating range'
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

connUnitSensorType 1.3.6.1.3.94.1.8.1.7
The type of component being monitored by this sensor.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), other(2), battery(3), fan(4), power-supply(5), transmitter(6), enclosure(7), board(8), receiver(9)  

connUnitSensorCharacteristic 1.3.6.1.3.94.1.8.1.8
The characteristics being monitored by this sensor.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), other(2), temperature(3), pressure(4), emf(5), currentValue(6), airflow(7), frequency(8), power(9), door(10)  

connUnitPortTable 1.3.6.1.3.94.1.10
Generic information on ports for a specific connUnit.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ConnUnitPortEntry

connUnitPortEntry 1.3.6.1.3.94.1.10.1
Each entry contains the information for a specific port.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  ConnUnitPortEntry  

connUnitPortUnitId 1.3.6.1.3.94.1.10.1.1
The connUnitId of the connectivity unit that contains this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  FcGlobalId  

connUnitPortIndex 1.3.6.1.3.94.1.10.1.2
A unique value among all connUnitPortEntrys on this connectivity unit, between 1 and connUnitNumPort[connUnitPortUnitId].
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2147483647  

connUnitPortType 1.3.6.1.3.94.1.10.1.3
The port type.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), other(2), not-present(3), hub-port(4), n-port(5), nl-port(6), fl-port(7), f-port(8), e-port(9), g-port(10), domain-ctl(11), hub-controller(12), scsi(13), escon(14), lan(15), wan(16), ac(17), dc(18), ssa(19)  

connUnitPortFCClassCap 1.3.6.1.3.94.1.10.1.4
Bit mask that specifies the classes of service capability of this port. If this is not applicable, return all bits set to zero. The bits have the following definition: unknown - 0 class-f - 1 class-one - 2 class-two - 4 class-three - 8 class-four - 16 class-five - 32 class-six - 64
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(2)  

connUnitPortFCClassOp 1.3.6.1.3.94.1.10.1.5
Bit mask that specifies the classes of service that are currently operational. If this is not applicable, return all bits set to zero. This object has the same definition as connUnitPortFCClassCap
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(2)  

connUnitPortState 1.3.6.1.3.94.1.10.1.6
The user selected state of the port hardware.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), online(2), offline(3), bypassed(4), diagnostics(5)  

connUnitPortStatus 1.3.6.1.3.94.1.10.1.7
An overall protocol status for the port. This value of connUnitPortState is not online, then this is reported Unknown.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), unused(2), ready(3), warning(4), failure(5), notparticipating(6), initializing(7), bypass(8), ols(9)  

connUnitPortTransmitterType 1.3.6.1.3.94.1.10.1.8
The technology of the port transceiver.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), other(2), unused(3), shortwave(4), longwave(5), copper(6), scsi(7), longwaveNoOFC(8), shortwaveNoOFC(9), longwaveLED(10), ssa(11)  

connUnitPortModuleType 1.3.6.1.3.94.1.10.1.9
The module type of the port connector.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), other(2), gbic(3), embedded(4), glm(5), gbicSerialId(6), gbicNoSerialId(7), gbicNotInstalled(8), smallFormFactor(9)  

connUnitPortWwn 1.3.6.1.3.94.1.10.1.10
The World Wide Name of the port if applicable, otherwise all zeros.
Status: mandatory Access: read-only
OBJECT-TYPE    
  FcNameId  

connUnitPortFCId 1.3.6.1.3.94.1.10.1.11
This is the assigned Fibre Channel ID of this port. This value is expected to be a Big Endian value of 24 bits. If this is loop, then it is the ALPA that is connected. If this is an eport, then it will only contain the domain ID left justified, zero filled. If this port does not have a Fibre Channel address, return all bits set to 1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  FcAddressId  

connUnitPortSn 1.3.6.1.3.94.1.10.1.12
The serial number of the unit (e.g., for a GBIC). If this is not applicable, return empty string.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..79)  

connUnitPortRevision 1.3.6.1.3.94.1.10.1.13
The port revision (e.g., for a GBIC).
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..79)  

connUnitPortVendor 1.3.6.1.3.94.1.10.1.14
The port vendor (e.g., for a GBIC).
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..79)  

connUnitPortSpeed 1.3.6.1.3.94.1.10.1.15
The speed of the port in kilobytes per second.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

connUnitPortControl 1.3.6.1.3.94.1.10.1.16
This object is used to control the addressed connUnit's port. Valid commands are: resetConnUnitPort: If the addressed connUnit allows this operation to be performed to this port, the addressed port performs a vendor-specific 'reset' operation. Examples of these operations are: the Link Reset protocol, the Loop Initialization protocol, or a resynchronization occurring between the transceiver in the addressed port to the transceiver that the port is connected to. bypassConnUnitPort: If the addressed connUnit allows this operation to be performed to this port, the addressed port performs a vendor-specific 'bypass' operation. Examples of these operations are: transitioning from online to offline, a request(NON-PARTICIPATING) command to the Loop Port state machine, or removal of the port from an arbitrated loop by a hub. unbypassConnUnitPort: If the addressed connUnit allows this operation to be performed to this port, the addressed port performs a vendor-specific 'unbypass' operation. Examples of these operations are: the Link Failure protocol, a request(PARTICIPATING) command to the Loop Port state machine, or addition of the port to an arbitrated loop by a hub. offlineConnUnitPort: If the addressed connUnit allows this operation to be performed to this port, the addressed port performs a vendor-specific 'offline' operation. Examples of these operations are: disabling a port's transceiver, the Link Failure protocol, request(NON-PARTICIPATING) command to the Loop Port state machine, or removal of the port from an arbitrated loop by a hub. onlineConnUnitPort: If the addressed connUnit allows this operation to be performed to this port, the addressed port performs a vendor-specific 'online' operation. Examples of these operations are: enabling a port's transceiver, the Link Failure protocol, request(PARTICIPATING) command to the Loop Port state machine, or addition of the port from an arbitrated loop by a hub. resetConnUnitPortCounters: If the addressed connUnit allows this operation to be performed to this port, the addressed port statistics table counters will be set to zero. NOTE: Each implementation may chose not to allow any or all of these values on a SET. On a read, if you do not support write, then return invalid. Otherwise return the last control operation attempted.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), invalid(2), resetConnUnitPort(3), bypassConnUnitPort(4), unbypassConnUnitPort(5), offlineConnUnitPort(6), onlineConnUnitPort(7), resetConnUnitPortCounters(8)  

connUnitPortName 1.3.6.1.3.94.1.10.1.17
A user-defined name for this port. This means that up to DisplayString characters may be supported. If less than, then the name will be truncated in the connunit.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

connUnitPortPhysicalNumber 1.3.6.1.3.94.1.10.1.18
This is the internal port number this port is known by. In many implementations, this should be the same as connUnitPortIndex. Some implementations may have an internal port representation not compatible with the rules for table indeces. In that case, provide the internal representation of this port in this object. This value may also be used in the connUnitLinkPortNumberX or connUnitLinkPortNumberY objects of the connUnitLinkTable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

connUnitPortStatObject 1.3.6.1.3.94.1.10.1.19
This contains the OID of the first object of the table that contains the statistics for this particular port. If this has a value of zero, then there are no statistics available for this port. The port type information will help identify the statistics objects that will be found in the table.
Status: deprecated Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

connUnitPortProtocolCap 1.3.6.1.3.94.1.10.1.20
Bit mask that specifies the driver level protocol capability of this port. If this is not applicable, return all bits set to zero. The bits have the following definition: unknown - 0 Loop - 1 Fabric - 2 SCSI - 4 TCP/IP - 8 VI - 16 FICON - 32
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(2)  

connUnitPortProtocolOp 1.3.6.1.3.94.1.10.1.21
Bit mask that specifies the driver level protocol(s) that are currently operational. If this is not applicable, return all bits set to zero. This object has the same definition as connUnitPortProtocolCap
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(2)  

connUnitPortNodeWwn 1.3.6.1.3.94.1.10.1.22
The Node World Wide Name of the port if applicable, otherwise all zeros. This should have the same value for a group of related ports. The container is defined as the largest physical entity. For example, all ports on HBAs on a host will have the same Node WWN. All ports on the same storage subsystem will have the same Node WWN.
Status: mandatory Access: read-only
OBJECT-TYPE    
  FcNameId  

connUnitPortHWState 1.3.6.1.3.94.1.10.1.23
The hardware detected state of the port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), failed(2), bypassed(3), active(4), loopback(5), txfault(6), noMedia(7), linkDown(8)  

connUnitEventTable 1.3.6.1.3.94.1.11
The table of connectivity unit events. Errors, warnings, and information should be reported in this table.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ConnUnitEventEntry

connUnitEventEntry 1.3.6.1.3.94.1.11.1
Each entry contains information on a specific event for the given connectivity unit.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  ConnUnitEventEntry  

connUnitEventUnitId 1.3.6.1.3.94.1.11.1.1
The connUnitId of the connectivity unit that contains this event table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  FcGlobalId  

connUnitEventIndex 1.3.6.1.3.94.1.11.1.2
Each connectivity unit has its own event buffer. As it wraps, it may write over previous events. This object is an index into the buffer. It is recommended that this table be read using 'getNext's to retrieve the initial table. The management application should read the event table at periodic intervals and then determine if any new entries were added by comparing the last known index value with the current highest index value. The management application should then update its copy of the event table. If the read interval is too long, it is possible that there may be events that may not be contained in the agent's internal event buffer. For example, an agent may read events 50-75. At the next read interval, connUnitEventCurrID is 189. If the management app tries to read event index 76, and the agent's internal buffer is 100 entries max, event index 76 will no longer be available. The index value is an incrementing integer starting from one every time there is a table reset. On table reset, all contents are emptied and all indeces are set to zero. When an event is added to the table, the event is assigned the next higher integer value than the last item entered into the table. If the index value reaches its maximum value, the next item entered will cause the index value to roll over and start at one again.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2147483647  

connUnitEventId 1.3.6.1.3.94.1.11.1.3
The internal event Id. Incremented for each event, ranging between 1 and connUnitMaxEvents. Not used as table index to simplify the agent implementation. When this reaches the end of the range specified by connUnitMaxEvents, the Id will roll over to start at one. This value will be set back to one at reset. The relationship of this value to the index is that internal event id may represent a smaller number than a 32 bit integer (eg max 100 entries) and would only have a value range up to connUnitMaxEvents.
Status: deprecated Access: read-only
OBJECT-TYPE    
  INTEGER  

connUnitREventTime 1.3.6.1.3.94.1.11.1.4
This is the real time when the event occurred. It has the following format. DDMMYYYY HHMMSS DD=day number MM=month number YYYY=year number HH=hour number MM=minute number SS=seconds number If not applicable, return either a NULL string or '00000000 000000'.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..15)  

connUnitSEventTime 1.3.6.1.3.94.1.11.1.5
This is the sysuptime timestamp when the event occurred.
Status: mandatory Access: read-only
OBJECT-TYPE    
  TimeTicks  

connUnitEventSeverity 1.3.6.1.3.94.1.11.1.6
The event severity level.
Status: mandatory Access: read-only
OBJECT-TYPE    
  FcEventSeverity  

connUnitEventType 1.3.6.1.3.94.1.11.1.7
The type of this event.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), other(2), status(3), configuration(4), topology(5)  

connUnitEventObject 1.3.6.1.3.94.1.11.1.8
This is used with the connUnitEventType to identify which object the event refers to. Examples are connUnitPortStatus.connUnitId.connUnitPortIndex, connUnitStatus.connUnitId, etc.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

connUnitEventDescr 1.3.6.1.3.94.1.11.1.9
The description of the event.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

connUnitLinkTable 1.3.6.1.3.94.1.12
A list of links know to this agent from this connectivity unit to other connectivity units.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ConnUnitLinkEntry

connUnitLinkEntry 1.3.6.1.3.94.1.12.1
An entry describing a particular link to another.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  ConnUnitLinkEntry  

connUnitLinkUnitId 1.3.6.1.3.94.1.12.1.1
The connUnitId of the connectivity unit that contains this link table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  FcGlobalId  

connUnitLinkIndex 1.3.6.1.3.94.1.12.1.2
This index is used to create a unique value for each entry in the link table with the same connUnitLinkUnitId. The value can only be reused if it is not currently in use and the value is the next candidate to be used. This value wraps at the highest value represented by the size of INTEGER. This value is reset to zero when the system is reset and the first value to be used is one.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2147483647  

connUnitLinkNodeIdX 1.3.6.1.3.94.1.12.1.3
The node WWN of the unit at one end of the link. If the node WWN is unknown and the node is a connUnit in the responding agent then the value of this object MUST BE equal to its connUnitID.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(16)  

connUnitLinkPortNumberX 1.3.6.1.3.94.1.12.1.4
The port number on the unit specified by connUnitLinkNodeIdX if known, otherwise -1. If the value is nonnegative then it will be equal to connUnitPortPhysicalNumber.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

connUnitLinkPortWwnX 1.3.6.1.3.94.1.12.1.5
The port WWN of the unit specified by connUnitLinkNodeIdX if known, otherwise 16 octets of binary 0
Status: mandatory Access: read-only
OBJECT-TYPE    
  FcGlobalId  

connUnitLinkNodeIdY 1.3.6.1.3.94.1.12.1.6
The node WWN of the unit at the other end of the link. If the node WWN is unknown and the node is a connUnit in the responding SNMP agency then the value of this object MUST BE equal to its connUnitID.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(16)  

connUnitLinkPortNumberY 1.3.6.1.3.94.1.12.1.7
The port number on the unit specified by connUnitLinkNodeIdY if known, otherwise -1. If the value is nonnegative then it will be equal to connUnitPortPhysicalNumber.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

connUnitLinkPortWwnY 1.3.6.1.3.94.1.12.1.8
The port WWN on the unit specified by connUnitLinkNodeIdY if known, otherwise 16 octets of binary 0
Status: mandatory Access: read-only
OBJECT-TYPE    
  FcGlobalId  

connUnitLinkAgentAddressY 1.3.6.1.3.94.1.12.1.9
The address of an FCMGMT MIB agent for the node identified by connUnitLinkNodeIdY, if known; otherwise 16 octets of binary 0
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(16)  

connUnitLinkAgentAddressTypeY 1.3.6.1.3.94.1.12.1.10
If connUnitLinkAgentAddressY is nonzero, it is a protocol address. ConnUnitLinkAgentAddressTypeY is the the 'address family number' assigned by IANA to identify the address format. (eg, 1 is Ipv4, 2 is Ipv6). If connUnitLinkAgentAddressY is all zeros, then this value is ignored.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

connUnitLinkAgentPortY 1.3.6.1.3.94.1.12.1.11
The IP port number for the agent. This is provided in case the agent is at a non-standard SNMP port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

connUnitLinkUnitTypeY 1.3.6.1.3.94.1.12.1.12
Type of the FC connectivity unit as defined in connUnitType.
Status: mandatory Access: read-only
OBJECT-TYPE    
  FcUnitType  

connUnitLinkConnIdY 1.3.6.1.3.94.1.12.1.13
This is the Fibre Channel ID of this port. If the connectivity unit is a switch, this is expected to be a Big Endian value of 24 bits. If this is loop, then it is the ALPA that is connected. If this is an eport, then it will only contain the domain ID. If not any of those, unknown or cascaded loop, return all bits set to 1.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(3)  

connUnitLinkCurrIndex 1.3.6.1.3.94.1.12.1.14
The last used link index.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

connUnitPortStatTable 1.3.6.1.3.94.4.5
A list of statistics for the fabric port types.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ConnUnitPortStatEntry

connUnitPortStatEntry 1.3.6.1.3.94.4.5.1
An entry describing port statistics.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  ConnUnitPortStatEntry  

connUnitPortStatUnitId 1.3.6.1.3.94.4.5.1.1
The connUnitId of the connectivity unit that contains this port stat table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  FcGlobalId  

connUnitPortStatIndex 1.3.6.1.3.94.4.5.1.2
A unique value among all entrys in this table, between 0 and connUnitNumPort[connUnitPortUnitId].
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..2147483647  

connUnitPortStatCountError 1.3.6.1.3.94.4.5.1.3
A count of the errors that have occured on this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

connUnitPortStatCountTxObjects 1.3.6.1.3.94.4.5.1.4
The number of frames/packets/IOs/etc that have been transmitted by this port. Note: A Fibre Channel frame starts with SOF and ends with EOF. FC loop devices should not count frames passed through. This value represents the sum total for all other Tx objects.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

connUnitPortStatCountRxObjects 1.3.6.1.3.94.4.5.1.5
The number of frames/packets/IOs/etc that have been received by this port. Note: A Fibre Channel frame starts with SOF and ends with EOF. FC loop devices should not count frames passed through. This value represents the sum total for all other Rx objects.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

connUnitPortStatCountTxElements 1.3.6.1.3.94.4.5.1.6
The number of octets or bytes that have been transmitted by this port. One second periodic polling of the port. This value is saved and compared with the next polled value to compute net throughput. Note, for Fibre Channel, ordered sets are not included in the count.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

connUnitPortStatCountRxElements 1.3.6.1.3.94.4.5.1.7
The number of octets or bytes that have been received. by this port. One second periodic polling of the port. This value is saved and compared with the next polled value to compute net throughput. Note, for Fibre Channel, ordered sets are not included in the count.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

connUnitPortStatCountBBCreditZero 1.3.6.1.3.94.4.5.1.8
Count of transitions in/out of BBcredit zero state. The other side is not providing any credit. Note, this is a Fibre Channel stat only.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

connUnitPortStatCountInputBuffersFull 1.3.6.1.3.94.4.5.1.9
Count of occurrences when all input buffers of a port were full and outbound buffer-to-buffer credit transitioned to zero. There is no credit to provide to other side. Note, this is a Fibre Channel stat only.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

connUnitPortStatCountFBSYFrames 1.3.6.1.3.94.4.5.1.10
Count of times that FBSY was returned to this port as a result of a frame that could not be delivered to the other end of the link. This occurs if either the Fabric or the destination port is temporarily busy. Port can only occur on SOFc1 frames (the frames that establish a connection). Note, this is a Fibre Channel only stat. This is the sum of all classes. If you cannot keep the by class counters, then keep the sum counters.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

connUnitPortStatCountPBSYFrames 1.3.6.1.3.94.4.5.1.11
Count of times that PBSY was returned to this port as a result of a frame that could not be delivered to the other end of the link. This occurs if the destination port is temporarily busy. PBSY can only occur on SOFc1 frames (the frames that establish a connection). Note, this is a Fibre Channel only stat.This is the sum of all classes. If you cannot keep the by class counters, then keep the sum counters.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

connUnitPortStatCountFRJTFrames 1.3.6.1.3.94.4.5.1.12
Count of times that FRJT was returned to this port as a result of a Frame that was rejected by the fabric. Note, This is the total for all classes and is a Fibre Channel only stat.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

connUnitPortStatCountPRJTFrames 1.3.6.1.3.94.4.5.1.13
Count of times that FRJT was returned to this port as a result of a Frame that was rejected at the destination N_Port. Note, This is the total for all classes and is a Fibre Channel only stat.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

connUnitPortStatCountClass1RxFrames 1.3.6.1.3.94.4.5.1.14
Count of Class 1 Frames received at this port. Note, this is a Fibre Channel only stat.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

connUnitPortStatCountClass1TxFrames 1.3.6.1.3.94.4.5.1.15
Count of Class 1 Frames transmitted out this port. Note, this is a Fibre Channel only stat.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

connUnitPortStatCountClass1FBSYFrames 1.3.6.1.3.94.4.5.1.16
Count of times that FBSY was returned to this port as a result of a Class 1 Frame that could not be delivered to the other end of the link. This occurs if either the Fabric or the destination port is temporarily busy. FBSY can only occur on SOFc1 frames (the frames that establish a connection). Note, this is a Fibre Channel only stat.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

connUnitPortStatCountClass1PBSYFrames 1.3.6.1.3.94.4.5.1.17
Count of times that PBSY was returned to this port as a result of a Class 1 Frame that could not be delivered to the other end of the link. This occurs if the destination N_Port is temporarily busy. PBSY can only occur on SOFc1 frames (the frames that establish a connection). Note, this is a Fibre Channel only stat.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

connUnitPortStatCountClass1FRJTFrames 1.3.6.1.3.94.4.5.1.18
Count of times that FRJT was returned to this port as a result of a Class 1 Frame that was rejected by the fabric. Note, this is a Fibre Channel only stat.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

connUnitPortStatCountClass1PRJTFrames 1.3.6.1.3.94.4.5.1.19
Count of times that FRJT was returned to this port as a result of a Class 1 Frame that was rejected at the destination N_Port. Note, this is a Fibre Channel only stat.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

connUnitPortStatCountClass2RxFrames 1.3.6.1.3.94.4.5.1.20
Count of Class 2 Frames received at this port. Note, this is a Fibre Channel only stat.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

connUnitPortStatCountClass2TxFrames 1.3.6.1.3.94.4.5.1.21
Count of Class 2 Frames transmitted out this port. Note, this is a Fibre Channel only stat.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

connUnitPortStatCountClass2FBSYFrames 1.3.6.1.3.94.4.5.1.22
Count of times that FBSY was returned to this port as a result of a Class 2 Frame that could not be delivered to the other end of the link. This occurs if either the Fabric or the destination port is temporarily busy. FBSY can only occur on SOFc1 frames (the frames that establish a connection). Note, this is a Fibre Channel only stat.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

connUnitPortStatCountClass2PBSYFrames 1.3.6.1.3.94.4.5.1.23
Count of times that PBSY was returned to this port as a result of a Class 2 Frame that could not be delivered to the other end of the link. This occurs if the destination N_Port is temporarily busy. PBSY can only occur on SOFc1 frames (the frames that establish a connection). Note, this is a Fibre Channel only stat.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

connUnitPortStatCountClass2FRJTFrames 1.3.6.1.3.94.4.5.1.24
Count of times that FRJT was returned to this port as a result of a Class 2 Frame that was rejected by the fabric. Note, this is a Fibre Channel only stat.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

connUnitPortStatCountClass2PRJTFrames 1.3.6.1.3.94.4.5.1.25
Count of times that FRJT was returned to this port as a result of a Class 2 Frame that was rejected at the destination N_Port. Note, this is a Fibre Channel only stat.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

connUnitPortStatCountClass3RxFrames 1.3.6.1.3.94.4.5.1.26
Count of Class 3 Frames received at this port. Note, this is a Fibre Channel only stat.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

connUnitPortStatCountClass3TxFrames 1.3.6.1.3.94.4.5.1.27
Count of Class 3 Frames transmitted out this port. Note, this is a Fibre Channel only stat.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

connUnitPortStatCountClass3Discards 1.3.6.1.3.94.4.5.1.28
Count of Class 3 Frames that were discarded upon reception at this port. There is no FBSY or FRJT generated for Class 3 Frames. They are simply discarded if they cannot be delivered. Note, this is a Fibre Channel only stat.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

connUnitPortStatCountRxMulticastObjects 1.3.6.1.3.94.4.5.1.29
Count of Multicast Frames or Packets received at this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

connUnitPortStatCountTxMulticastObjects 1.3.6.1.3.94.4.5.1.30
Count of Multicast Frames or Packets transmitted out this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

connUnitPortStatCountRxBroadcastObjects 1.3.6.1.3.94.4.5.1.31
Count of Broadcast Frames or Packets received at this port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

connUnitPortStatCountTxBroadcastObjects 1.3.6.1.3.94.4.5.1.32
Count of Broadcast Frames or Packets transmitted out this port. On a Fibre Channel loop, count only OPNr frames generated.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

connUnitPortStatCountRxLinkResets 1.3.6.1.3.94.4.5.1.33
Count of Link resets. This is the number of LRs received. Note, this is a Fibre Channel only stat.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

connUnitPortStatCountTxLinkResets 1.3.6.1.3.94.4.5.1.34
Count of Link resets. This is the number LRs transmitted. Note, this is a Fibre Channel only stat.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

connUnitPortStatCountNumberLinkResets 1.3.6.1.3.94.4.5.1.35
Count of Link resets and LIPs detected at this port. The number times the reset link protocol is initiated. These are the count of the logical resets, a count of the number of primatives. Note, this is a Fibre Channel only stat.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

connUnitPortStatCountRxOfflineSequences 1.3.6.1.3.94.4.5.1.36
Count of Offline Primitive OLS received at this port. Note, this is a Fibre Channel only stat.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

connUnitPortStatCountTxOfflineSequences 1.3.6.1.3.94.4.5.1.37
Count of Offline Primitive OLS transmitted by this port. Note, this is a Fibre Channel only stat.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

connUnitPortStatCountNumberOfflineSequences 1.3.6.1.3.94.4.5.1.38
Count of Offline Primitive sequence received at this port. Note, this is a Fibre Channel only stat.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

connUnitPortStatCountLinkFailures 1.3.6.1.3.94.4.5.1.39
Count of link failures. This count is part of the Link Error Status Block (LESB). (FC-PH 29.8). Note, this is a Fibre Channel only stat.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

connUnitPortStatCountInvalidCRC 1.3.6.1.3.94.4.5.1.40
Count of frames received with invalid CRC. This count is part of the Link Error Status Block (LESB). (FC-PH 29.8). Loop ports should not count CRC errors passing through when monitoring. Note, this is a Fibre Channel only stat.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

connUnitPortStatCountInvalidTxWords 1.3.6.1.3.94.4.5.1.41
Count of invalid transmission words received at this port. This count is part of the Link Error Status Block (LESB). (FC-PH 29.8). Note, this is a Fibre Channel only stat.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

connUnitPortStatCountPrimitiveSequenceProtocolErrors 1.3.6.1.3.94.4.5.1.42
Count of primitive sequence protocol errors detected at this port. This count is part of the Link Error Status Block (LESB). (FC-PH 29.8). Note, this is a Fibre Channel only stat.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

connUnitPortStatCountLossofSignal 1.3.6.1.3.94.4.5.1.43
Count of instances of signal loss detected at port. This count is part of the Link Error Status Block (LESB). (FC-PH 29.8). Note, this is a Fibre Channel only stat.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

connUnitPortStatCountLossofSynchronization 1.3.6.1.3.94.4.5.1.44
Count of instances of synchronization loss detected at port. This count is part of the Link Error Status Block (LESB). (FC-PH 29.8). Note, this is a Fibre Channel only stat.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

connUnitPortStatCountInvalidOrderedSets 1.3.6.1.3.94.4.5.1.45
Count of invalid ordered sets received at port. This count is part of the Link Error Status Block (LESB). (FC-PH 29.8). Note, this is a Fibre Channel only stat.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

connUnitPortStatCountFramesTooLong 1.3.6.1.3.94.4.5.1.46
Count of frames received at this port where the frame length was greater than what was agreed to in FLOGI/PLOGI. This could be caused by losing the end of frame delimiter. Note, this is a Fibre Channel only stat.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

connUnitPortStatCountFramesTruncated 1.3.6.1.3.94.4.5.1.47
Count of frames received at this port where the frame length was less than the minimum indicated by the frame header - normally 24 bytes, but it could be more if the DFCTL field indicates an optional header should have been present. Note, this is a FC only stat.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

connUnitPortStatCountAddressErrors 1.3.6.1.3.94.4.5.1.48
Count of frames received with unknown addressing. e.x. unknown SID or DID. the SID or DID is not known to the routing algorithm. Note. this is a FC only stat.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

connUnitPortStatCountDelimiterErrors 1.3.6.1.3.94.4.5.1.49
Count of invalid frame delimiters received at this port. An example is a frame with a class 2 start and a class 3 at the end. Note, this is a FC only stat.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

connUnitPortStatCountEncodingDisparityErrors 1.3.6.1.3.94.4.5.1.50
Count of disparity errors received at this port. Note, this is a Fibre Channel only stat.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(8)  

connUnitSnsMaxEntry 1.3.6.1.3.94.5.1.1
The maximum number of entries in the table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

connUnitSnsTable 1.3.6.1.3.94.5.2.1
This table contains an entry for each object registered with this port in the switch.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ConnUnitSnsEntry

connUnitSnsEntry 1.3.6.1.3.94.5.2.1.1
The Simple Name Server table for the port represented by ConnUnitSnsPortIndex .
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  ConnUnitSnsEntry  

connUnitSnsId 1.3.6.1.3.94.5.2.1.1.1
The connUnitId of the connectivity unit that contains this Name Server table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(16)  

connUnitSnsPortIndex 1.3.6.1.3.94.5.2.1.1.2
The physical port number of this SNS table entry. Each physical port has an SNS table with 1-n entries indexed by ConnUnitSnsPortIdentifier (port address)
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

connUnitSnsPortIdentifier 1.3.6.1.3.94.5.2.1.1.3
The Port Identifier for this entry in the SNS table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  FcAddressId  

connUnitSnsPortName 1.3.6.1.3.94.5.2.1.1.4
The Port WWN for this entry in the SNS table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  FcNameId  

connUnitSnsNodeName 1.3.6.1.3.94.5.2.1.1.5
The Node Name for this entry in the SNS table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  FcNameId  

connUnitSnsClassOfSvc 1.3.6.1.3.94.5.2.1.1.6
The Classes of Service offered by this entry in the SNS table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(1)  

connUnitSnsNodeIPAddress 1.3.6.1.3.94.5.2.1.1.7
The IPv6 formatted address of the Node for this entry in the SNS table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(16)  

connUnitSnsProcAssoc 1.3.6.1.3.94.5.2.1.1.8
The Process Associator for this entry in the SNS table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(1)  

connUnitSnsFC4Type 1.3.6.1.3.94.5.2.1.1.9
The FC-4 Types supported by this entry in the SNS table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(1)  

connUnitSnsPortType 1.3.6.1.3.94.5.2.1.1.10
The Port Type of this entry in the SNS table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(1)  

connUnitSnsPortIPAddress 1.3.6.1.3.94.5.2.1.1.11
The IPv6 formatted address of this entry in the SNS table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(16)  

connUnitSnsFabricPortName 1.3.6.1.3.94.5.2.1.1.12
The Fabric Port name of this entry in the SNS table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  FcNameId  

connUnitSnsHardAddress 1.3.6.1.3.94.5.2.1.1.13
The Hard ALPA of this entry in the SNS table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  FcAddressId  

connUnitSnsSymbolicPortName 1.3.6.1.3.94.5.2.1.1.14
The Symbolic Port Name of this entry in the SNS table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..79)  

connUnitSnsSymbolicNodeName 1.3.6.1.3.94.5.2.1.1.15
The Symbolic Node Name of this entry in the SNS table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..79)  

trapMaxClients 1.3.6.1.3.94.2.1
The maximum number of SNMP trap recipients supported by the connectivity unit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

trapClientCount 1.3.6.1.3.94.2.2
The current number of rows in the trap table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

trapRegTable 1.3.6.1.3.94.2.3
A table containing a row for each IP address/port number that traps will be sent to.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    TrapRegEntry

trapRegEntry 1.3.6.1.3.94.2.3.1
Ip/Port pair for a specific client.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  TrapRegEntry  

trapRegIpAddress 1.3.6.1.3.94.2.3.1.1
The Ip address of a client registered for traps.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

trapRegPort 1.3.6.1.3.94.2.3.1.2
The UDP port to send traps to for this host. Normally this would be the standard trap port (162). This object is an index and must be specified to create a row in this table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..2147483647  

trapRegFilter 1.3.6.1.3.94.2.3.1.3
This value defines the trap severity filter for this trap host. The connUnit will send traps to this host that have a severity level less than or equal to this value. The default value of this object is 'warning'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  FcEventSeverity  

trapRegRowState 1.3.6.1.3.94.2.3.1.4
Specifies the state of the row. rowDestroy READ: Can never happen. WRITE: Remove this row from the table. rowInactive READ: Indicates that this row does exist, but that traps are not enabled to be sent to the target. WRITE: If the row does not exist, and the agent allows writes to the trap table, then a new row is created. The values of the optional columns will be set to default values. Traps are not enabled to be sent to the target. If the row already existed, then traps are disabled from being sent to the target. rowActive READ: Indicates that this row exists, and that traps are enabled to be sent to the target. WRITE: If the row does not exist, and the agent allows writes to the trap table, then a new row is created. The values of the optional columns will be set to default values. Traps are enabled to be sent to the target. If the row already exists, then traps are enabled to be sent to the target. A value of rowActive or rowInactive must be specified to create a row in the table.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER rowDestroy(1), rowInactive(2), rowActive(3)  

connUnitStatusChange 1
The overall status of the connectivity unit has changed. Recommended severity level (for filtering): alert
TRAP-TYPE    

connUnitDeletedTrap 3
A connUnit has been deleted from this agent. Recommended severity level (for filtering): warning
TRAP-TYPE    

connUnitEventTrap 4
An event has been generated by the connectivity unit. Recommended severity level (for filtering): info
TRAP-TYPE    

connUnitSensorStatusChange 5
The overall status of the connectivity unit has changed. Recommended severity level (for filtering): alert
TRAP-TYPE    

connUnitPortStatusChange 6
The overall status of the connectivity unit has changed. Recommended severity level (for filtering): alert
TRAP-TYPE