EXTREME-SYSTEM-MIB

File: EXTREME-SYSTEM-MIB.mib (81355 bytes)

Imported modules

SNMPv2-TC SNMPv2-SMI RFC1213-MIB
EXTREME-BASE-MIB

Imported symbols

TEXTUAL-CONVENTION Counter64 NOTIFICATION-TYPE
MODULE-IDENTITY OBJECT-TYPE Integer32
Unsigned32 TruthValue RowStatus
DisplayString extremeAgent PortList
sysDescr sysUpTime ifDescr
MacAddress IpAddress

Defined Types

SlotType  
The type of the slot. It is used both for the configured as well as the inserted slot types.
TEXTUAL-CONVENTION    
  INTEGER none(1), fe32(2), g4x(3), g6x(4), fe32fx(5), msm(6), f48ti(7), g8xi(8), g8ti(9), g12sxi(10), g12ti(11), msm64i(18), alpine3808(19), alpine3804(20), fm32t(21), gm4x(22), gm4sx(23), gm4t(24), wdm8(25), fm24f(26), fm24sf(27), fm24te(28), f96ti(29), wdm4(30), f32fi(31), tenGig(32), tenGigLR(33), g16x3(34), g24t3(35), gm16x3(36), gm16t3(37), fm16t3(38), fm32p(39), fm8v(50), wm4t1(51), wm4t3(52), wm1t3(53), wm4e1(54), alpine3802(55), p3c(101), p12c(102), arm(103), mpls(104), sma(105), p48c(106), a3c(107), a12c(108), pxm(200), s300fixed(201), msm3(202), msm1(203), msm1xl(204), s300expansion(301), g60t(400), g60x(401), teng6x(402), msm-g8x(414), g8x(415), g48t(416), g48p(417), g24x(418), teng4x(419), teng2x(420), g20x(421), teng2h(422), msm5(425), msm5r(426), gm20t(427), gm20xt(428), gm20xtr(429), xm2x(430), xm2xr(431), msm6r(432), g48te(433), g48ta(434), g48pe(435), g48x(437), x450a-24t(439), x450e-24p(440), x450a-48t(442), x450e-48p(443), x450a-24x(444), x450a-24tdc(445), x450a-24xdc(446), msm-48(447), teng4ca(448), teng4xa(449), g48tc(450), g48te2(451), g48xc(452), g24xc(453), tenG4xc(454), tenG8xc(455), msms48c(456), g8xc(457), tenG1xc(458), g48tcPoE(459), g48te2PoE(460), x450a-48tdc(461), x250e-24t(462), x250e-24p(463), x250e-48t(464), x250e-48p(465), x250e-24x(466), x250e-24xtaa(467), x250e-24tdc(468), x250e-48tdc(469), x250e-24xdc(470), x150-24t(471), x150-24tdc(472), x150-24p(473), x150-48t(474), x150-48tdc(475), x150-48p(476), x150-24x(477), x150-24xdc(478), xm2hr(480), x350-24t(481), x350-48t(482), x650-24t(483), x650-24x(484), x650-24tG4X(485), x650-24xG4X(486), x650-24tG4X10G2S(487), x650-24xG4X10G2S(488), x650-24t10G8X10G2S(489), x650-24x10G8X10G2S(490), x650-24t64G2S(491), x650-24x64G2S(492), x650-24t64G4S(493), x650-24x64G4S(494), mmbase(496), mmadv(497), gm40xb(498), xm8xb(500), x8900msm128(503), x8900tenG24xc(504), x8900tenG8xm(505), x8900g48tm(506), x8900g48xm(507), x8900g96tc(508), x8900g48tmPoE(509), nwie450a(510), x480-24x(511), x480-48x(512), x480-48t(513), x480-24x10G2S(514), x480-48x10G2S(515), x480-48t10G2S(516), x480-24x10G4X(517), x480-48x10G4X(518), x480-48t10G4X(519), x480-24x32G2S(520), x480-48x32G2S(521), x480-48t32G2S(522), x8500msm48(523), x8500g24xa(524), x8500g48te(525), x8500g48tePoE(526), x460-24t(527), x460-24p(528), x460-24x(529), x460-48t(530), x460-48p(531), x460-48x(532), x450e-24t(533), x450e-48t(534), hm-2x24ga(535), xcm88s1(536), xcm8848t(537), xcm88p(538), xcm8824f(539), xcm8808x(540), xcm888f(541), x480-48x20G2S(542), x480-48t20G2S(543), x670-48x(546), x670v-48x(547), e4g-400(548), bdx-mm1(549), bdxa-10g48x(550), bdxa-10g24x(551), bdxa-40g24x(552), bdxa-40g12x(553), bdxa-fm960(554), bdxa-fm480(555), x480-24x20G2S(556), x650-24x40G4X(557), x650-24t40G4X(558), x480-24x40G4X(559), x480-48x40G4X(560), x480-48t40G4X(561), tenG2xc(562), fortyG6xc(563), e4g-200(564), x440-8t(565), x440-8p(566), x440-24t(567), x440-24p(568), x440-48t(569), x440-48p(570), x440-24t-10G(571), x440-24p-10G(572), x440-48t-10G(573), x440-48p-10G(574), ags100-24t(575), ags150-24p(576), x670v-48t(578), x440-L2-24t(579), x440-L2-48t(580), x440-24x(582), x440-48x(583), bdxa-10g48t(584), x430-24t(585), x430-48t(586), x440-24tdc(587), x440-48tdc(588)  

PowerValue  
The input power value of the switch.
TEXTUAL-CONVENTION    
  INTEGER v110(1), v220(2), v48DC(3), unknown(4)  

UnitMultiplier  
The Unit Multiplier is an integer value that represents the IEEE 61850 Annex A units multiplier associated with the integer units used to measure the power or energy. For example, when used with pmPowerUnitMultiplier, -3 represents 10^-3 or milliwatts.
TEXTUAL-CONVENTION    
  INTEGER yocto(-24), zepto(-21), atto(-18), femto(-15), pico(-12), nano(-9), micro(-6), milli(-3), units(0), kilo(3), mega(6), giga(9), tera(12), peta(15), exa(18), zetta(21), yotta(24)  

ExtremeFanStatusEntry  
SEQUENCE    
  extremeFanNumber Integer32
  extremeFanOperational TruthValue
  extremeFanEntPhysicalIndex Integer32
  extremeFanSpeed Integer32

ExtremePowerSupplyEntry  
SEQUENCE    
  extremePowerSupplyNumber Integer32
  extremePowerSupplyStatus INTEGER
  extremePowerSupplyInputVoltage PowerValue
  extremePowerSupplySerialNumber DisplayString
  extremePowerSupplyEntPhysicalIndex Integer32
  extremePowerSupplyFan1Speed INTEGER
  extremePowerSupplyFan2Speed INTEGER
  extremePowerSupplySource INTEGER
  extremePowerSupplyInputPowerUsage Integer32
  extremePowerMonSupplyNumOutput Integer32
  extremePowerSupplyInputPowerUsageUnitMultiplier UnitMultiplier

ExtremeCpuTask2Entry  
SEQUENCE    
  extremeCpuTask2CpuId Unsigned32
  extremeCpuTask2Name DisplayString
  extremeCpuTask2Id Unsigned32
  extremeCpuTask2Pc Unsigned32
  extremeCpuTask2Status DisplayString
  extremeCpuTask2Utilization Unsigned32
  extremeCpuTask2MaxUtilization Unsigned32

ExtremeImageEntry  
SEQUENCE    
  extremeImageNumber INTEGER
  extremeMajorVersion Integer32
  extremeSubMajorVersion Integer32
  extremeMinorVersion Integer32
  extremeBuildNumber Integer32
  extremeTechnologyReleaseNumber Integer32
  extremeSustainingReleaseNumber Integer32
  extremeBranchRevisionNumber Integer32
  extremeImageType INTEGER
  extremeImageDescription DisplayString
  extremeImageSecurity INTEGER
  extremePatchVersion Integer32

ExtremeImageFeatureEntry  
SEQUENCE    
  extremeImageFeatureNumber INTEGER
  extremeImageSshCapability INTEGER
  extremeImageUAACapability INTEGER

ExtremePowerSupplyOutputPowerEntry  
SEQUENCE    
  extremePowerSupplyIndex Integer32
  extremePowerSupplyOutputSensorIdx Integer32
  extremePowerSupplyOutputVoltage Integer32
  extremePowerSupplyOutputCurrent Integer32
  extremePowerSupplyOutputUnitMultiplier UnitMultiplier

ExtremePowerSupplyUsageEntry  
SEQUENCE    
  extremeSlotIndex Integer32
  extremePowerSupplyUsageValue Integer32
  extremePowerSupplyUnitMultiplier UnitMultiplier

ExtremeSystemPowerMonitorEntry  
SEQUENCE    
  extremeSystemPowerMonitorIndex1 Integer32
  extremeSystemPowerMonitorPollInterval INTEGER
  extremeSystemPowerMonitorReportChanges INTEGER
  extremeSystemPowerMonitorChangeThreshold Integer32

RebootTimeEntry  
SEQUENCE    
  extremeRebootSlotId INTEGER
  extremeRebootNodeAddress MacAddress
  extremeRebootModuleSlotId DisplayString
  extremeRebootSlotNumber INTEGER
  extremeRebootAsStandby INTEGER
  extremeRebootStackTopology INTEGER
  extremeRebootMonth INTEGER
  extremeRebootDay INTEGER
  extremeRebootYear INTEGER
  extremeRebootHour INTEGER
  extremeRebootMinute INTEGER
  extremeRebootSeconds INTEGER
  extremeRebootCancel INTEGER
  extremeRebootImmediate INTEGER
  extremeRebootRowStatus RowStatus

ExtremeDownloadImageEntry  
SEQUENCE    
  extremeDownloadImageSlotId INTEGER
  extremeDownloadImageStatus INTEGER
  extremeDownloadImageFilename DisplayString
  extremeDownloadImagePartition INTEGER
  extremeDownloadImageHostName DisplayString
  extremeDownloadImageIpaddress DisplayString
  extremeDownloadImageStartTime DisplayString
  extremeDownloadImageMemorycard INTEGER
  extremeDownloadImageInstall INTEGER
  extremeDownloadSlotNumber INTEGER
  extremeDownloadModuleSlotId DisplayString
  extremeDownloadRowStatus RowStatus

ExtremeInstallImageEntry  
SEQUENCE    
  extremeInstallImageSlotId INTEGER
  extremeInstallImageStatus INTEGER
  extremeInstallImageFilename DisplayString
  extremeInstallImagePartition INTEGER
  extremeInstallImageStartTime DisplayString
  extremeInstallImageReboot INTEGER
  extremeInstallImageModuleSlotId DisplayString
  extremeInstallImageSlotNumber INTEGER
  extremeInstallImageRowStatus RowStatus

ExtremeSlotEntry  
SEQUENCE    
  extremeSlotNumber Integer32
  extremeSlotName DisplayString
  extremeSlotModuleConfiguredType INTEGER
  extremeSlotModuleInsertedType INTEGER
  extremeSlotModuleState INTEGER
  extremeSlotModuleSerialNumber DisplayString

Defined Values

extremeSystem 1.3.6.1.4.1.1916.1.1
Extreme System objects: objects common to all platforms
MODULE-IDENTITY    

extremeSystemCommon 1.3.6.1.4.1.1916.1.1.1
OBJECT IDENTIFIER    

extremeSystemPowerUsage 1.3.6.1.4.1.1916.1.1.1.40
OBJECT IDENTIFIER    

extremeSaveConfiguration 1.3.6.1.4.1.1916.1.1.1.3
When this object is set, the device will copy the contents of the configuration database to a buffer and save it to the persistant store specified by the value of the object. The save is performed asynchronously, and the snmp agent will continue to respond to both gets and sets while the save is taking place. A network management application may use the extremeSaveStatus object to determine when the asynchronous save operation has completed.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER saveToPrimary(1), saveToSecondary(2), saveToCurrent(3), factoryDefault(4), saveToFile(5)  

extremeSaveStatus 1.3.6.1.4.1.1916.1.1.1.4
This object will return the status of a save operation invoked by setting the extremeSaveConfiguration object. A network management application can read this object to determine that a save operation has completed.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER saveInProgress(1), saveNotInProgress(2), saveNotReady(3)  

extremeCurrentConfigInUse 1.3.6.1.4.1.1916.1.1.1.5
Shows which NVRAM configuration store was used at last boot.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER primary(1), secondary(2), other(3), factoryDefault(4)  

extremeConfigToUseOnReboot 1.3.6.1.4.1.1916.1.1.1.6
Controls which NVRAM configuration store will be used on next reboot.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER primary(1), secondary(2), other(3)  

extremeSaveConfigurationFileName 1.3.6.1.4.1.1916.1.1.1.48
This object is set, along the object extremSaveConfiguration option with value 5.This object indicates the file name to be used while saving the file. On reading it returns the current selected config.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..127)  

extremeUseOnRebootFileName 1.3.6.1.4.1.1916.1.1.1.49
This object is set, along the object extremeConfigToUseOnReboot option with value 3.This object indicates the file name to be used while saving the file
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..127)  

extremeOverTemperatureAlarm 1.3.6.1.4.1.1916.1.1.1.7
Alarm status of overtemperature sensor in device enclosure.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

extremeCurrentTemperature 1.3.6.1.4.1.1916.1.1.1.8
Current temperature in degrees celcius measured inside device enclosure.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

extremeFanStatusTable 1.3.6.1.4.1.1916.1.1.1.9
Table of operational status of all internal cooling fans.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ExtremeFanStatusEntry

extremeFanStatusEntry 1.3.6.1.4.1.1916.1.1.1.9.1
Entry in table of all internal cooling fans.
Status: current Access: not-accessible
OBJECT-TYPE    
  ExtremeFanStatusEntry  

extremeFanNumber 1.3.6.1.4.1.1916.1.1.1.9.1.1
Identifier of cooling fan, numbered from the front and/or left side of device.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

extremeFanOperational 1.3.6.1.4.1.1916.1.1.1.9.1.2
Operational status of a cooling fan.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

extremeFanEntPhysicalIndex 1.3.6.1.4.1.1916.1.1.1.9.1.3
The entity index for this fan entity in the entityPhysicalTable table of the entity MIB.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

extremeFanSpeed 1.3.6.1.4.1.1916.1.1.1.9.1.4
The speed (RPM) of a cooling fan in the fantray.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

extremePrimaryPowerOperational 1.3.6.1.4.1.1916.1.1.1.10
Operational status of internal power supply of a device.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

extremeRedundantPowerStatus 1.3.6.1.4.1.1916.1.1.1.11
Operational status of an external redundant power supply to a device.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notPresent(1), presentOK(2), presentNotOK(3)  

extremeRedundantPowerAlarm 1.3.6.1.4.1.1916.1.1.1.12
Alarm state of an external redundant power supply to a device. Alarm state indicates either fan failure or overtemperature condition.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

extremePrimarySoftwareRev 1.3.6.1.4.1.1916.1.1.1.13
The software revision of the primary image stored in this device. This string will have a zero length if the revision is unknown, invalid or not present. This will also be reported in RMON2 probeSoftwareRev if this is the software image currently running in the device.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

extremeSecondarySoftwareRev 1.3.6.1.4.1.1916.1.1.1.14
The software revision of the secondary image stored in this device. This string will have a zero length if the revision is unknown, invalid or not present. This will also be reported in RMON2 probeSoftwareRev if this is the software image currently running in the device.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

extremeImageToUseOnReboot 1.3.6.1.4.1.1916.1.1.1.15
Controls which image will be used on next reboot.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER primary(1), secondary(2)  

extremeSystemID 1.3.6.1.4.1.1916.1.1.1.16
This represents the System ID of the Summit Switch.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..126)  

extremeSystemBoardID 1.3.6.1.4.1.1916.1.1.1.17
This represents the Board ID of the Summit Switch.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..126)  

extremeSystemLeftBoardID 1.3.6.1.4.1.1916.1.1.1.18
This represents the Left Board ID of the Summit Switch.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..126)  

extremeSystemRightBoardID 1.3.6.1.4.1.1916.1.1.1.19
This represents the Right Board ID of the Summit Switch.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..126)  

extremeInputPowerVoltage 1.3.6.1.4.1.1916.1.1.1.20
The input power voltage at which the system is currently operating.
Status: current Access: read-only
OBJECT-TYPE    
  PowerValue  

extremePowerStatus 1.3.6.1.4.1.1916.1.1.1.21
Operational status of the power supply to a device.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notPresent(1), presentOK(2), presentNotOK(3)  

extremePowerAlarm 1.3.6.1.4.1.1916.1.1.1.22
Alarm state of the power supply to a device. Alarm state indicates either fan failure or overtemperature condition.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

extremeRmonEnable 1.3.6.1.4.1.1916.1.1.1.23
Setting this to true will cause the agent to start collecting RMON statistics.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

extremeBootROMVersion 1.3.6.1.4.1.1916.1.1.1.25
The software revision of the bootrom on the device. This string will have a zero length if the revision is unknown or invalid.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..15)  

extremeDot1dTpFdbTableEnable 1.3.6.1.4.1.1916.1.1.1.26
Setting this to true will cause GetNext operations on the dot1dTpFdbTable to be allowed. Note that Get operations are always allowed.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

extremePowerSupplyTable 1.3.6.1.4.1.1916.1.1.1.27
Table of status of all power supplies in the system.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ExtremePowerSupplyEntry

extremePowerSupplyEntry 1.3.6.1.4.1.1916.1.1.1.27.1
An entry indicating the status of a specific power supply.
Status: current Access: not-accessible
OBJECT-TYPE    
  ExtremePowerSupplyEntry  

extremePowerSupplyNumber 1.3.6.1.4.1.1916.1.1.1.27.1.1
Power supply number.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

extremePowerSupplyStatus 1.3.6.1.4.1.1916.1.1.1.27.1.2
Status of the power supply.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notPresent(1), presentOK(2), presentNotOK(3), presentPowerOff(4)  

extremePowerSupplyInputVoltage 1.3.6.1.4.1.1916.1.1.1.27.1.3
Input voltage of the power supply
Status: current Access: read-only
OBJECT-TYPE    
  PowerValue  

extremePowerSupplySerialNumber 1.3.6.1.4.1.1916.1.1.1.27.1.4
The serial number of the power supply unit.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..126)  

extremePowerSupplyEntPhysicalIndex 1.3.6.1.4.1.1916.1.1.1.27.1.5
The entity index for this psu entity in the entityPhysicalTable of the entity MIB.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

extremePowerSupplyFan1Speed 1.3.6.1.4.1.1916.1.1.1.27.1.6
The speed (RPM) of Fan-1 in the power supply unit.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notPresent(-1), noRPMInfo(-2)  

extremePowerSupplyFan2Speed 1.3.6.1.4.1.1916.1.1.1.27.1.7
The speed (RPM) of Fan-2 in the power supply unit.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notPresent(-1), noRPMInfo(-2)  

extremePowerSupplySource 1.3.6.1.4.1.1916.1.1.1.27.1.8
The power supply unit input source.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), ac(2), dc(3), externalPowerSupply(4), internalRedundant(5)  

extremePowerSupplyInputPowerUsage 1.3.6.1.4.1.1916.1.1.1.27.1.9
Input power usage for the given psu slot. The value 0 in this field indicate the power usage is not supported or read failure.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

extremePowerMonSupplyNumOutput 1.3.6.1.4.1.1916.1.1.1.27.1.10
Number of output sensors in the power supply unit
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

extremePowerSupplyInputPowerUsageUnitMultiplier 1.3.6.1.4.1.1916.1.1.1.27.1.11
The magnitude of watts for the usage value in extremePowerSupplyInputPowerUsage.
Status: current Access: read-only
OBJECT-TYPE    
  UnitMultiplier  

extremeCpuAggregateUtilization 1.3.6.1.4.1.1916.1.1.1.28
The aggregate CPU utilization since the time the start started executing.
Status: deprecated Access: read-only
OBJECT-TYPE    
  Integer32  

extremeCpuTask2Table 1.3.6.1.4.1.1916.1.1.1.29
Table of CPU tasks that are active.
Status: deprecated Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ExtremeCpuTask2Entry

extremeCpuTask2Entry 1.3.6.1.4.1.1916.1.1.1.29.1
An entry in table of describes a single task.
Status: deprecated Access: not-accessible
OBJECT-TYPE    
  ExtremeCpuTask2Entry  

extremeCpuTask2CpuId 1.3.6.1.4.1.1916.1.1.1.29.1.1
CPU on which this task last executed or is executing. The primary CPU has a value of 1.
Status: deprecated Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

extremeCpuTask2Name 1.3.6.1.4.1.1916.1.1.1.29.1.2
Name associated with the reported task id.
Status: deprecated Access: not-accessible
OBJECT-TYPE    
  DisplayString Size(0..31)  

extremeCpuTask2Id 1.3.6.1.4.1.1916.1.1.1.29.1.3
Task identifier assigned by the operating system when this task is spawned.
Status: deprecated Access: read-only
OBJECT-TYPE    
  Unsigned32  

extremeCpuTask2Pc 1.3.6.1.4.1.1916.1.1.1.29.1.4
The value of the program counter for this task. It indicates the address of the next instruction that would be executed once the operating system resumes this task.
Status: deprecated Access: read-only
OBJECT-TYPE    
  Unsigned32  

extremeCpuTask2Status 1.3.6.1.4.1.1916.1.1.1.29.1.5
The current status of the task as reported by the operating system.
Status: deprecated Access: read-only
OBJECT-TYPE    
  DisplayString  

extremeCpuTask2Utilization 1.3.6.1.4.1.1916.1.1.1.29.1.6
The current CPU utilization by this task. This is the utilization when the task last executed.
Status: deprecated Access: read-only
OBJECT-TYPE    
  Unsigned32  

extremeCpuTask2MaxUtilization 1.3.6.1.4.1.1916.1.1.1.29.1.7
The maximum CPU utilization by this task since the time the start started executing. This value may be cleared.
Status: deprecated Access: read-write
OBJECT-TYPE    
  Unsigned32  

extremeAuthFailSrcAddr 1.3.6.1.4.1.1916.1.1.1.30
The IP address of the originator of the bad SNMP request that caused the generation of an authentication failure trap.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  IpAddress  

extremeCpuTransmitPriority 1.3.6.1.4.1.1916.1.1.1.31
The CPU transmit priority.
Status: deprecated Access: read-write
OBJECT-TYPE    
  INTEGER normal(1), high(2)  

extremeImageBooted 1.3.6.1.4.1.1916.1.1.1.32
The image with which the switch was last booted, using which it is currently running.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER primary(1), secondary(2)  

extremeMsmFailoverCause 1.3.6.1.4.1.1916.1.1.1.33
The cause of the last MSM failover. never(1) means an MSM Failover has not occurred since the last reboot. admin(2) means the failover was initiated by the user. exception(3) means the former master MSM encountered a software exception condition. removal(4) means the master MSM was physically removed from the chassis. hwFailure(5) means a diagnostic failure was detected in the master MSM. watchdog(6) means that the master MSM hardware watchdog timer expired. keepalive(7) means the master MSM failed to respond to slave keepalive requests. The MSM failover will have been hitless only in the admin(2) and exception(3) cases
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER never(1), admin(2), exception(3), removal(4), hwFailure(5), watchdog(6), keepalive(7)  

extremeImageTable 1.3.6.1.4.1.1916.1.1.1.34
A table containing information about each software image.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ExtremeImageEntry

extremeImageEntry 1.3.6.1.4.1.1916.1.1.1.34.1
A table entry containing information about each software image.
Status: current Access: not-accessible
OBJECT-TYPE    
  ExtremeImageEntry  

extremeImageNumber 1.3.6.1.4.1.1916.1.1.1.34.1.1
A unique integer identifying the particular software image.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER cur(0), pri(1), sec(2), curr(3)  

extremeMajorVersion 1.3.6.1.4.1.1916.1.1.1.34.1.2
The ExtremeWare Release Major Version.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

extremeSubMajorVersion 1.3.6.1.4.1.1916.1.1.1.34.1.3
The ExtremeWare Release Sub-major Version.
Status: deprecated Access: read-only
OBJECT-TYPE    
  Integer32  

extremeMinorVersion 1.3.6.1.4.1.1916.1.1.1.34.1.4
The ExtremeWare Release Minor Version.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

extremeBuildNumber 1.3.6.1.4.1.1916.1.1.1.34.1.5
The ExtremeWare Build Number.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

extremeTechnologyReleaseNumber 1.3.6.1.4.1.1916.1.1.1.34.1.6
The Technology Release version. This value is zero for all but TR releases.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

extremeSustainingReleaseNumber 1.3.6.1.4.1.1916.1.1.1.34.1.7
The Sustaining Release number for the ExtremeWare version.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

extremeBranchRevisionNumber 1.3.6.1.4.1.1916.1.1.1.34.1.8
The incremental build on specified branch.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

extremeImageType 1.3.6.1.4.1.1916.1.1.1.34.1.9
The branch type from which the image was built.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER trunk(0), branch(1), patch(2), technology(3), beta(4)  

extremeImageDescription 1.3.6.1.4.1.1916.1.1.1.34.1.10
A unique string that can be used to identify the specific patch, technology, or development branch release.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

extremeImageSecurity 1.3.6.1.4.1.1916.1.1.1.34.1.11
Indicates whether image was built with ssh. This object is deprecated, the ssh capability can be obtained from the extremeImageSshCapability of the ImageFeatureTable
Status: deprecated Access: read-only
OBJECT-TYPE    
  INTEGER unknown(0), nossh(1), ssh(2)  

extremePatchVersion 1.3.6.1.4.1.1916.1.1.1.34.1.12
The ExtremeWare Release Patch Version.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

extremeImageFeatureTable 1.3.6.1.4.1.1916.1.1.1.35
A table containing information about the software features.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ExtremeImageFeatureEntry

extremeImageFeatureEntry 1.3.6.1.4.1.1916.1.1.1.35.1
A table entry containing information about software features.
Status: current Access: not-accessible
OBJECT-TYPE    
  ExtremeImageFeatureEntry  

extremeImageFeatureNumber 1.3.6.1.4.1.1916.1.1.1.35.1.1
A unique integer identifying the particular software image.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER cur(0), pri(1), sec(2)  

extremeImageSshCapability 1.3.6.1.4.1.1916.1.1.1.35.1.2
Indicates whether image has ssh capability.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(0), nossh(1), ssh(2)  

extremeImageUAACapability 1.3.6.1.4.1.1916.1.1.1.35.1.3
Indicates whether image has Wireless(UAA) components.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER unknown(0), nouaa(1), uaa(2)  

extremeSystemPowerState 1.3.6.1.4.1.1916.1.1.1.36
The current state of power available.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER computing(1), sufficientButNotRedundantPower(2), redundantPowerAvailable(3), insufficientPower(4)  

extremeBootTime 1.3.6.1.4.1.1916.1.1.1.37
The boot time expressed in standard time_t value. When interpreted as an absolute time value, it represents the number of seconds elapsed since 00:00:00 on January 1, 1970, Coordinated Universal Time (UTC)
Status: current Access: read-only
OBJECT-TYPE    
  Counter64  

extremePowerSupplyOutputPowerTable 1.3.6.1.4.1.1916.1.1.1.38
The output power supply table per power supply unit.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ExtremePowerSupplyOutputPowerEntry

extremePowerSupplyOutputPowerEntry 1.3.6.1.4.1.1916.1.1.1.38.1
An entry in the power supply output table.
Status: current Access: not-accessible
OBJECT-TYPE    
  ExtremePowerSupplyOutputPowerEntry  

extremePowerSupplyIndex 1.3.6.1.4.1.1916.1.1.1.38.1.1
Power supply unit slot index
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

extremePowerSupplyOutputSensorIdx 1.3.6.1.4.1.1916.1.1.1.38.1.2
Power supply Sensor Index
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

extremePowerSupplyOutputVoltage 1.3.6.1.4.1.1916.1.1.1.38.1.3
Output voltage per sensor for the current psu slot no. 0 in this field tells the psu doesnt support output voltage reading or output voltage read error.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

extremePowerSupplyOutputCurrent 1.3.6.1.4.1.1916.1.1.1.38.1.4
Output current per sensor for the current psu slot no. 0 in this field tells the psu doesnt support output current reading or output current read error.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

extremePowerSupplyOutputUnitMultiplier 1.3.6.1.4.1.1916.1.1.1.38.1.5
The magnitude of volts and amps for the usage value in extremePowerSupplyOutputVoltage and extremePowerSupplyOutputCurrent.
Status: current Access: read-only
OBJECT-TYPE    
  UnitMultiplier  

extremePowerSupplyUsageTable 1.3.6.1.4.1.1916.1.1.1.39
The power supply usage on each slot.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ExtremePowerSupplyUsageEntry

extremePowerSupplyUsageEntry 1.3.6.1.4.1.1916.1.1.1.39.1
An entry in the power supply usage table.
Status: current Access: not-accessible
OBJECT-TYPE    
  ExtremePowerSupplyUsageEntry  

extremeSlotIndex 1.3.6.1.4.1.1916.1.1.1.39.1.1
Slot number in the chassis/stack based system.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

extremePowerSupplyUsageValue 1.3.6.1.4.1.1916.1.1.1.39.1.2
Power Usage of the particular slot in the chassis or stack.The power usage is measured in milli-watts.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

extremePowerSupplyUnitMultiplier 1.3.6.1.4.1.1916.1.1.1.39.1.3
The magnitude of watts for the usage value in extremePowerSupplyUsageValue.
Status: current Access: read-only
OBJECT-TYPE    
  UnitMultiplier  

extremeSystemPowerUsageValue 1.3.6.1.4.1.1916.1.1.1.40.1
The current power usage of the system.In stack mode this variables tells total power usage of the entire system.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

extremeSystemPowerUsageUnitMultiplier 1.3.6.1.4.1.1916.1.1.1.40.2
The magnitude of watts for the usage value in extremeSystemPowerUsageValue.
Status: current Access: read-only
OBJECT-TYPE    
  UnitMultiplier  

extremeSystemPowerMonitorTable 1.3.6.1.4.1.1916.1.1.1.41
The output power supply table per power supply unit.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ExtremeSystemPowerMonitorEntry

extremeSystemPowerMonitorEntry 1.3.6.1.4.1.1916.1.1.1.41.1
An entry in the power supply output table.
Status: current Access: not-accessible
OBJECT-TYPE    
  ExtremeSystemPowerMonitorEntry  

extremeSystemPowerMonitorIndex1 1.3.6.1.4.1.1916.1.1.1.41.1.1
Reserved can be used for future expansion. currently set to zero.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

extremeSystemPowerMonitorPollInterval 1.3.6.1.4.1.1916.1.1.1.41.1.2
Configure how often input power is measured. it is configured in seconds. default value is 60 seconds. if 0 is configured then the input power measurement is disabled
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..300  

extremeSystemPowerMonitorReportChanges 1.3.6.1.4.1.1916.1.1.1.41.1.3
configure report-changes has none or log or trap or log-and-trap, by default none is configured
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(1), log(2), trap(3), logandtrap(4)  

extremeSystemPowerMonitorChangeThreshold 1.3.6.1.4.1.1916.1.1.1.41.1.4
configure input power change-threshold to initiate report-changes action. By default 2 watts is configured, this field is configured in watts.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

extremeRebootTable 1.3.6.1.4.1.1916.1.1.1.42
This group of objects use to initiate a device reboot or contain details of the last reboot operation of the switch modules or nodes.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    RebootTimeEntry

rebootTimeEntry 1.3.6.1.4.1.1916.1.1.1.42.1
This group of objects use to initiate a device reboot or contain details of the last reboot operation of the switch modules or nodes.
Status: current Access: not-accessible
OBJECT-TYPE    
  RebootTimeEntry  

extremeRebootSlotId 1.3.6.1.4.1.1916.1.1.1.42.1.1
Specifies the MSM/MM module number of a switch or the slot number currently being used by the active stack node.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

extremeRebootNodeAddress 1.3.6.1.4.1.1916.1.1.1.42.1.2
Specifies the MAC address of the SummitStack node to be rebooted. NOTE: This object is valid only for Summit X250e and X450 series switches, and SummitStack.
Status: current Access: read-write
OBJECT-TYPE    
  MacAddress  

extremeRebootModuleSlotId 1.3.6.1.4.1.1916.1.1.1.42.1.3
Specifies A or B for an MSM/MM module. - A specifies the MSM/MM installed in slot A. - B specifies the MSM/MM installed in slot B. Note: The modules that can be rebooted are management switch fabric modules(MSM) and management modules(MM). This object is valid only on modular switches.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

extremeRebootSlotNumber 1.3.6.1.4.1.1916.1.1.1.42.1.4
Specifies the slot number currently being used by the active stack node that is to be rebooted. Note: This variable is available only on SummitStack.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

extremeRebootAsStandby 1.3.6.1.4.1.1916.1.1.1.42.1.5
Specifies that all stack nodes that are to be rebooted are to operate as if configured to not be master-capable. NOTE: This object is valid only for Summit X250e and X450 series switches and SummitStack.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(0)  

extremeRebootStackTopology 1.3.6.1.4.1.1916.1.1.1.42.1.6
Specifies that the entire SummitStack is to be rebooted whether or not nodes are active. NOTE: This object is valid only for Summit X250e and X450 series switches and SummitStack.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(0)  

extremeRebootMonth 1.3.6.1.4.1.1916.1.1.1.42.1.7
Specifies the month that the reboot is scheduled to start.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..12  

extremeRebootDay 1.3.6.1.4.1.1916.1.1.1.42.1.8
Specifies the day that the reboot is scheduled to start.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..31  

extremeRebootYear 1.3.6.1.4.1.1916.1.1.1.42.1.9
Specifies the year that the reboot is scheduled to start.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 2003..2036  

extremeRebootHour 1.3.6.1.4.1.1916.1.1.1.42.1.10
Specifies the hour that the reboot is scheduled to start.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..23  

extremeRebootMinute 1.3.6.1.4.1.1916.1.1.1.42.1.11
Specifies the number of minutes that the reboot is scheduled to start.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..59  

extremeRebootSeconds 1.3.6.1.4.1.1916.1.1.1.42.1.12
Specifies the number of seconds that the reboot is scheduled to start.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..59  

extremeRebootCancel 1.3.6.1.4.1.1916.1.1.1.42.1.13
Cancels a previously scheduled reboot. Note: This object, when enabled, override all objects associated with a reboot request.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(0)  

extremeRebootImmediate 1.3.6.1.4.1.1916.1.1.1.42.1.14
Indicates that a reboot should be executed on the target device immediately.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(0)  

extremeRebootRowStatus 1.3.6.1.4.1.1916.1.1.1.42.1.15
The existence state of this reboot request. This object follows the row status behavior.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

extremeDownloadImageTable 1.3.6.1.4.1.1916.1.1.1.43
This group of objects contain details of the last or the current download image operation of the switch modules or nodes.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ExtremeDownloadImageEntry

extremeDownloadImageEntry 1.3.6.1.4.1.1916.1.1.1.43.1
This group of objects contain details of the last or the current download image operation of one of the switch modules or nodes.
Status: current Access: not-accessible
OBJECT-TYPE    
  ExtremeDownloadImageEntry  

extremeDownloadImageSlotId 1.3.6.1.4.1.1916.1.1.1.43.1.1
Specifies the MSM/MM module number of a switch or the slot number currently being used by the active stack node.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 0..65535  

extremeDownloadImageStatus 1.3.6.1.4.1.1916.1.1.1.43.1.2
Specifies the status of the current down load operation.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER downloadInProgress(1), downloadOperationSuccess(2), downloadNotMaster(3), downloadNameLengthError(4), downloadInvalidFileType(5), downloadActivePartitionError(6), downloadIllegalHostname(7), downloadFailed(8), downloadInvalidIpaddr(9), downloadMemAllocFailed(10), downloadNotInActiveTop(11), downloadMissingFileName(12), downloadIllegalFileName(13), downloadOperationTimeout(14), downloadInvalidRowStatus(15)  

extremeDownloadImageFilename 1.3.6.1.4.1.1916.1.1.1.43.1.3
Specifies the file name of the downloading EXOS image.
Status: current Access: read-create
OBJECT-TYPE    
  DisplayString Size(0..128)  

extremeDownloadImagePartition 1.3.6.1.4.1.1916.1.1.1.43.1.4
Specifies which partition the image should be saved to primary or secondary. Select primary to save the image to the primary partition and secondary to save the image to the secondary partition. Note: Beginning with ExtremeXOS 12.1, an ExtremeXOS core image must be installed on the alternate (nonactive) partition. If a user tries to install on an active partition, the error message [Error: Image can only be installed to the non-active partition.] is displayed.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER primary(1), secondary(2)  

extremeDownloadImageHostName 1.3.6.1.4.1.1916.1.1.1.43.1.5
Specifies the hostname of the TFTP server from which the image should be obtained.
Status: current Access: read-create
OBJECT-TYPE    
  DisplayString Size(0..128)  

extremeDownloadImageIpaddress 1.3.6.1.4.1.1916.1.1.1.43.1.6
Specifies the IP address of the TFTP server from which the image should be obtained.
Status: current Access: read-create
OBJECT-TYPE    
  DisplayString Size(0..128)  

extremeDownloadImageStartTime 1.3.6.1.4.1.1916.1.1.1.43.1.7
Specifies the start time (date and time) of the current down load operation.
Status: current Access: read-create
OBJECT-TYPE    
  DisplayString Size(0..31)  

extremeDownloadImageMemorycard 1.3.6.1.4.1.1916.1.1.1.43.1.8
Specifies that the image should be obtained from a removable storage device, which can be a compact flash card or a USB 2.0 storage device.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER enabled(1), disabled(0)  

extremeDownloadImageInstall 1.3.6.1.4.1.1916.1.1.1.43.1.9
Specifies to start the install process after the successful download of the image.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER enabled(1), disabled(0)  

extremeDownloadSlotNumber 1.3.6.1.4.1.1916.1.1.1.43.1.10
Specifies the slot number currently being used by the active stack node that is to be rebooted. Note: This variable is available only on stackable switches in a stack.
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 1..8  

extremeDownloadModuleSlotId 1.3.6.1.4.1.1916.1.1.1.43.1.11
Specifies A or B for an MSM/MM module. - A specifies the MSM/MM installed in slot A. - B specifies the MSM/MM installed in slot B. Note: The modules that can be rebooted are management switch fabric modules(MSM) and management modules(MM). This object is valid only on modular switches.
Status: current Access: read-create
OBJECT-TYPE    
  DisplayString  

extremeDownloadRowStatus 1.3.6.1.4.1.1916.1.1.1.43.1.12
The existence state of this download image request. This object follows the row status behavior.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

extremeInstallImageTable 1.3.6.1.4.1.1916.1.1.1.44
This group of objects contain details of the last or the current install image operation of the switch modules or nodes.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ExtremeInstallImageEntry

extremeInstallImageEntry 1.3.6.1.4.1.1916.1.1.1.44.1
This group of objects contain details of the last or the current install image operation of one of the switch modules or nodes.
Status: current Access: not-accessible
OBJECT-TYPE    
  ExtremeInstallImageEntry  

extremeInstallImageSlotId 1.3.6.1.4.1.1916.1.1.1.44.1.1
Specifies the MSM/MM module number of a switch or the slot number currently being used by the active stack node.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

extremeInstallImageStatus 1.3.6.1.4.1.1916.1.1.1.44.1.2
Specifies the status of the current install image operation.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER installInProgress(1), installOperationSuccess(2), installOperationPending(3), installNameLengthError(4), installInvalidFileType(5), installActivePartitionError(6), installDwnloadSlotMismatch(7), installFailed(8), installNotPrimary(9), installMemAllocFailed(10), installNotInActiveTop(11), installMissingFileName(12), installIllegalFileName(13), installOperationTimeout(14), installOperBackupTimeout(15), installInvalidRowStatus(16)  

extremeInstallImageFilename 1.3.6.1.4.1.1916.1.1.1.44.1.3
Specifies the software image file.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..128)  

extremeInstallImagePartition 1.3.6.1.4.1.1916.1.1.1.44.1.4
Specifies which partition the image should be saved to: primary or secondary. Select primary to save the image to the primary partition and secondary to save the image to the secondary partition. Note: Beginning with ExtremeXOS 12.1, an ExtremeXOS core image must be installed on the alternate (nonactive) partition. If a user tries to install on an active partition, the error message [Error: Image can only be installed to the non-active partition.] is displayed.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER primary(1), secondary(2)  

extremeInstallImageStartTime 1.3.6.1.4.1.1916.1.1.1.44.1.5
Specifies the start time of the current install operation.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..31)  

extremeInstallImageReboot 1.3.6.1.4.1.1916.1.1.1.44.1.6
Specifies to reboot the switch after the image is installed.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(0)  

extremeInstallImageModuleSlotId 1.3.6.1.4.1.1916.1.1.1.44.1.7
Specifies A or B for an MSM/MM module. - A specifies the MSM/MM installed in slot A. - B specifies the MSM/MM installed in slot B. Note: The modules that can be rebooted are management switch fabric modules(MSM) and management modules(MM). This object is valid only on modular switches.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

extremeInstallImageSlotNumber 1.3.6.1.4.1.1916.1.1.1.44.1.8
Specifies the slot number currently being used by the active stack node that is to be rebooted. Note: This variable is available only on stackable switches in a stack.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..8  

extremeInstallImageRowStatus 1.3.6.1.4.1.1916.1.1.1.44.1.9
The existence state of this install image request. This object follows the row status behavior.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

extremeLoadInstallTrap 1.3.6.1.4.1.1916.1.1.1.45
OBJECT IDENTIFIER    

loadInstallControl 1.3.6.1.4.1.1916.1.1.1.45.1
OBJECT IDENTIFIER    

loadInstallTraps 1.3.6.1.4.1.1916.1.1.1.45.2
OBJECT IDENTIFIER    

downloadImageTrapEnable 1.3.6.1.4.1.1916.1.1.1.45.1.1
This variable indicates whether the system produces the downloadImageTrap notification. A no(2) value will prevent notifications from being generated by this system.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

installImageTrapEnable 1.3.6.1.4.1.1916.1.1.1.45.1.2
This variable indicates whether the system produces the extremeInstallImageTrap notification. A no(2) value will prevent notifications from being generated by this system.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER yes(1), no(2)  

downloadImageTrap 1.3.6.1.4.1.1916.1.1.1.45.2.1
This notification indicates the status of the last/current download operation.
Status: current Access: read-write
NOTIFICATION-TYPE    

installImageTrap 1.3.6.1.4.1.1916.1.1.1.45.2.2
This notification indicates the status of the last/current install operation.
Status: current Access: read-write
NOTIFICATION-TYPE    

extremeChassisGroup 1.3.6.1.4.1.1916.1.1.2
OBJECT IDENTIFIER    

extremeMasterMSMSlot 1.3.6.1.4.1.1916.1.1.2.1
The extremeSlotNumber of the master MSM module.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

extremeChassisPortsPerSlot 1.3.6.1.4.1.1916.1.1.2.3
The maximum number of ports that can be accomodated in a single slot. This number would change to accomodate blades with higher port density than current ones.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

extremeSlotTable 1.3.6.1.4.1.1916.1.1.2.2
A table containing information about each slot in the chassis.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ExtremeSlotEntry

extremeSlotEntry 1.3.6.1.4.1.1916.1.1.2.2.1
A table entry containing information about the module in each slot of the chassis.
Status: current Access: not-accessible
OBJECT-TYPE    
  ExtremeSlotEntry  

extremeSlotNumber 1.3.6.1.4.1.1916.1.1.2.2.1.1
A unique integer identifying the particular slot in the chassis.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

extremeSlotName 1.3.6.1.4.1.1916.1.1.2.2.1.2
A name identifying the particular slot in the chassis.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

extremeSlotModuleConfiguredType 1.3.6.1.4.1.1916.1.1.2.2.1.3
The configured module type for the given slot. At startup, the module-type is none(1). It is possible to configure the module-type even if there is no module in the slot. If the current module in the slot is different than the requested configured module-type, then the current configuration for the module is erased and the card will be restarted. The new configured module-type will be recorded. Since the configured module type is different than the actual module type, a moduleMismatch trap will be sent, and the extremeSlotModuleState for that module will show a mismatch(3). Setting this variable to none(1) will clear the previously assigned module-type of this slot, and all configuration information related to the slot will be erased.
Status: current Access: read-write
OBJECT-TYPE    
  SlotType  

extremeSlotModuleInsertedType 1.3.6.1.4.1.1916.1.1.2.2.1.4
The module type inserted into the slot. It is possible to have a slot inserted into the slot even though extremeSlotConfiguredType is none(1).
Status: current Access: read-only
OBJECT-TYPE    
  SlotType  

extremeSlotModuleState 1.3.6.1.4.1.1916.1.1.2.2.1.5
The state of the module inserted in this slot.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER notPresent(1), testing(2), mismatch(3), failed(4), operational(5), powerdown(6), unknown(7), present(8), poweron(9), post(10), downloading(11), booting(12), offline(13), initializing(14), invalid(100)  

extremeSlotModuleSerialNumber 1.3.6.1.4.1.1916.1.1.2.2.1.6
The serial number of the module inserted in this slot.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

extremeSystemHealthCheck 1.3.6.1.4.1.1916.1.1.3
OBJECT IDENTIFIER    

extremeHealthCheckErrorType 1.3.6.1.4.1.1916.1.1.3.1
The error reported in the system health check trap
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  INTEGER unknown(1), cpuPacket(2), backplane(3), hardwareFail(4), pbusChecksum(5)  

extremeHealthCheckAction 1.3.6.1.4.1.1916.1.1.3.2
The action/alarm level configured for health check.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER syslogOnly(1), healthCheckTrap(2), ioModuleDown(3), systemDown(4), autoRecovery(5)  

extremeHealthCheckMaxRetries 1.3.6.1.4.1.1916.1.1.3.3
The maximum number of times a module restart will be attempted if it fails. If extremeHealthCheckAction is not autorecovery(5), then this value is zero.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

extremeSystemThresholds 1.3.6.1.4.1.1916.1.1.4
OBJECT IDENTIFIER    

extremeCpuUtilRisingThreshold 1.3.6.1.4.1.1916.1.1.4.1
Rising threshold for CPU Aggregation utilization trap
Status: deprecated Access: read-write
OBJECT-TYPE    
  INTEGER 0..100  

extremeCpuTaskUtilPair 1.3.6.1.4.1.1916.1.1.4.2
TaskName/CPU_% Util pair reported in CPU Utilization trap
Status: deprecated Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString  

extremeSystemNotifications 1.3.6.1.4.1.1916.1.1.6
OBJECT IDENTIFIER    

extremeSystemTrapsPrefix 1.3.6.1.4.1.1916.1.1.6.0
OBJECT IDENTIFIER    

extremeSystemPowerStatus 1.3.6.1.4.1.1916.1.1.6.0.1
Change in status of System Power The trap will not be generated for discovering state.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

extremeGenericTrap 1.3.6.1.4.1.1916.1.1.6.0.2
Some event took place in the system
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

extremeGenericTrapParams 1.3.6.1.4.1.1916.1.1.7
OBJECT IDENTIFIER    

severity 1.3.6.1.4.1.1916.1.1.7.1
The severity of the message being sent.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  INTEGER critical(1), error(2), warning(3), notice(4), info(5), debug-summary(6), debug-verbose(7), debug-data(8)  

eventName 1.3.6.1.4.1.1916.1.1.7.2
The event name being sent.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString Size(0..40)  

message 1.3.6.1.4.1.1916.1.1.7.3
The message being sent
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  DisplayString Size(0..256)  

extremePsuPowerStatus 1.3.6.1.4.1.1916.1.1.6.0.3
Trap to indicate change in status of Power Supply.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

extremeSystemPowerUsageNotification 1.3.6.1.4.1.1916.1.1.6.0.4
Whenever the power usage is increased/decreased by the configured threshold value then the power usage trap is generated if the trap is enabled..
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE