ES-RACKTIVITY-MIB

File: ES-RACKTIVITY-MIB.mib (136038 bytes)

Imported modules

SNMPv2-SMI SNMPv2-CONF SNMPv2-TC

Imported symbols

TimeTicks Unsigned32 Integer32
IpAddress MODULE-IDENTITY NOTIFICATION-TYPE
OBJECT-TYPE enterprises OBJECT-GROUP
MODULE-COMPLIANCE NOTIFICATION-GROUP TEXTUAL-CONVENTION
DisplayString MacAddress

Defined Types

Version  
Displays a version number
TEXTUAL-CONVENTION    
  OCTET STRING Size(4)  

Utenth  
0.1
TEXTUAL-CONVENTION    
  Unsigned32  

Uhundredth  
0.01
TEXTUAL-CONVENTION    
  Unsigned32  

Uthousandth  
0.001
TEXTUAL-CONVENTION    
  Unsigned32  

Stenth  
0.1
TEXTUAL-CONVENTION    
  Integer32  

Shundredth  
0.01
TEXTUAL-CONVENTION    
  Integer32  

Sthousandth  
0.001
TEXTUAL-CONVENTION    
  Integer32  

EVENTFLAGS  
enumeration of all eventflags possible
TEXTUAL-CONVENTION    
  INTEGER sNMPTrapOff(0), sNMPTrapOn(1)  

CURPORTSTATE  
enumeration of all port states possible
TEXTUAL-CONVENTION    
  INTEGER portOff(0), portOnNoWarning(1), portOff1(2), portOnWithWarningCurrent(3), portOff2(4), portOnWithWarningPower(5), portOff3(6), portOnWithWarningCurrentAndPower(7), portOffWithError(8), portOnNoWarning1(9), portOffWithError1(10), portOnWithWarningCurrent1(11), portOffWithError2(12), portOnWithWarningPower1(13), portOffWithError3(14), portOnWithWarnCurrentAndPower1(15), portOffWithDelayOn(16), portOnNoWarning2(17), portOffWithDelayOn1(18), portOnWithWarningCurrent2(19), portOffWithDelayOn2(20), portOnWithWarningPower2(21), portOffWithDelayOn3(22), portOnWithWarnCurrentAndPower2(23)  

EMasterEntry  
SEQUENCE    
  mGeneralModuleStatus Unsigned32
  mSpecificModuleStatus Unsigned32
  mCurrentTime TimeTicks
  mVoltage Uhundredth
  mTemperature Utenth
  mCurrentIP IpAddress
  mTotalCurrent Uthousandth
  mTotalRealPower Unsigned32
  mTotalActiveEnergy Uthousandth
  mLineCurrent Uthousandth
  mFuseCurrent Uthousandth
  mCurrentSubNetMask IpAddress
  mCurrentDNSServer IpAddress
  mCurrentStdGateway IpAddress
  mUPSPresent Unsigned32
  mUPSStatus Unsigned32
  mUPSEstimatedRunTime Unsigned32
  mUPSBatteryLevel Utenth
  mHighCurrent Stenth
  mUpsCommunicationStatus Unsigned32
  mHighPower Shundredth
  mTotalHighCurrent Stenth
  mTotalHighPower Shundredth
  mPositiveEnergy Uthousandth
  mNegativeEnergy Uthousandth
  mTotalPositiveEnergy Uthousandth
  mTotalNegativeEnergy Uthousandth
  mCloudStatus Unsigned32
  mStatus Unsigned32
  mModuleName DisplayString
  mFirmwareVersion Version
  mHardwareVersion Version
  mFirmwareID DisplayString
  mHardwareID DisplayString
  mRackName DisplayString
  mRackPosition DisplayString
  mIPAddress IpAddress
  mSubNetMask IpAddress
  mStdGateWay IpAddress
  mDnsServer IpAddress
  mMAC MacAddress
  mDHCPEnable Unsigned32
  mNTPServer IpAddress
  mUseDefaultNTPServer Unsigned32
  mUseNTP Unsigned32
  mSNMPTrapRecvIP IpAddress
  mSNMPTrapRecvPort Unsigned32
  mSNMPControl Unsigned32
  mECSServer IpAddress
  mUseECSServer Unsigned32
  mDisplayLock Unsigned32
  mDisplayTimeOn Unsigned32
  mMaxVoltageWarning Uhundredth
  mMinVoltageWarning Uhundredth
  mMinTemperatureWarning Utenth
  mMaxTemperatureWarning Utenth
  mGeneralEventEnable EVENTFLAGS
  mSNMPSysContact DisplayString
  mCurrentWarningEvent EVENTFLAGS
  mPowerWarningEvent EVENTFLAGS
  mTotalCurrentWarningEvent EVENTFLAGS
  mTotalPowerWarningEvent EVENTFLAGS
  mVoltageWarningEvent EVENTFLAGS
  mTemperatureWarningEvent EVENTFLAGS
  mDisplayBrightness Unsigned32
  mECSServerPort Unsigned32
  mExternalSensorLabel DisplayString
  mHttpsOnly Unsigned32
  mTelnetSsl Unsigned32
  mCookieTimeToLive Unsigned32
  mLineCurrentWarningThreshold Uthousandth
  mLineCurrentOffThreshold Uthousandth
  mLineCurrentWarningEvent EVENTFLAGS
  mLineCurrentOffEvent EVENTFLAGS
  mFuseCurrentWarningThreshold Uthousandth
  mFuseCurrentOffThreshold Uthousandth
  mFuseCurrentWarningEvent EVENTFLAGS
  mFuseCurrentOffEvent EVENTFLAGS
  mDeviceID DisplayString
  mDeviceVersion Version
  mSysName DisplayString
  mElectricalTopology Unsigned32
  mFusePortTopology Unsigned32
  mLineFuseTopology Unsigned32
  mSSOIPAddress IpAddress
  mSSOLoginCredentials DisplayString
  mSSOGracefullShutdown DisplayString
  mUPSWarningLevel Utenth
  mUPSOffLevel Utenth
  mMaxHighCurrentWarning Stenth
  mUpsMonitoringProtocol Unsigned32
  mUpsEmergencyThreshold Utenth
  mUpsRecoveryThreshold Utenth
  mUpsEventFlags EVENTFLAGS
  mRecoveryPowerThreshold Unsigned32
  mMinHighCurrentWarning Stenth
  mMinHighPowerWarning Shundredth
  mMaxHighPowerWarning Shundredth
  mHeartbeatInterval Unsigned32
  mMinTotalHighCurrentWarning Stenth
  mMaxTotalHighCurrentWarning Stenth
  mMinTotalHighPowerWarning Shundredth
  mMaxTotalHighPowerWarning Shundredth
  mCloudState Unsigned32
  mSensorBias Integer32
  mDaisyChainDeviceMode Unsigned32
  mSNMPTrapUser Unsigned32
  mUSMUser DisplayString
  mUSMAuthPassphrase DisplayString
  mUSMPrivPassphrase DisplayString
  mSNMPV2GetSetEnable Unsigned32
  mSNMPV3GetSetEnable Unsigned32
  mUSMAuthPassphraseLength Unsigned32
  mUSMPrivPassphraseLength Unsigned32
  mSNMPTrapEnable Unsigned32
  mLDAPAttribute DisplayString
  mLDAPPath DisplayString
  mLDAPAdminGroupName DisplayString
  mLDAPRestrictedGroupName DisplayString
  mLDAPGuestGroupName DisplayString
  mLDAPEnable Unsigned32
  mLDAPLoginWrapper DisplayString
  mLDAPServer DisplayString
  mLocalAuthEnable Unsigned32
  masterIndex Integer32
  masterModuleIndex Integer32

EPowerEntry  
SEQUENCE    
  pGeneralModuleStatus Unsigned32
  pSpecificModuleStatus Unsigned32
  pCurrentTime TimeTicks
  pVoltage Uhundredth
  pFrequency Uthousandth
  pCurrent Uthousandth
  pPower Unsigned32
  pStatePortCur CURPORTSTATE
  pActiveEnergy Uthousandth
  pApparentEnergy Uthousandth
  pTemperature Utenth
  pApparentPower Unsigned32
  pPowerFactor Unsigned32
  pTotalCurrent Uthousandth
  pTotalRealPower Unsigned32
  pTotalApparentPower Unsigned32
  pTotalActiveEnergy Uthousandth
  pTotalApparentEnergy Uthousandth
  pTotalPowerFactor Unsigned32
  pTimeOnline Unsigned32
  pTotalHarmonicDistortion Utenth
  pPhase Unsigned32
  pBigCurrent Unsigned32
  pBigPower Uthousandth
  pBigApparentPower Uthousandth
  pDetectedPhase Unsigned32
  pModuleName DisplayString
  pFirmwareVersion Version
  pHardwareVersion Version
  pFirmwareID DisplayString
  pHardwareID DisplayString
  pPortName DisplayString
  pPortState Unsigned32
  pCurrentPriorOff Unsigned32
  pDelayOn Unsigned32
  pMaxCurrentOff Uthousandth
  pMaxCurrentWarning Uthousandth
  pMaxPowerOff Unsigned32
  pMaxPowerWarning Unsigned32
  pMaxTotalCurrentOff Uthousandth
  pMaxTotalCurrentWarning Uthousandth
  pMaxTotalPowerOff Unsigned32
  pMaxTotalPowerWarning Unsigned32
  pMaxVoltageWarning Uhundredth
  pMinVoltageWarning Uhundredth
  pMinTemperatureWarning Utenth
  pMaxTemperatureWarning Utenth
  pPortStateEvent EVENTFLAGS
  pCurrentOffEvent EVENTFLAGS
  pCurrentWarningEvent EVENTFLAGS
  pPowerOffEvent EVENTFLAGS
  pPowerWarningEvent EVENTFLAGS
  pTotalCurrentOffEvent EVENTFLAGS
  pTotalCurrentWarningEvent EVENTFLAGS
  pTotalPowerOffEvent EVENTFLAGS
  pTotalPowerWarningEvent EVENTFLAGS
  pVoltageWarningEvent EVENTFLAGS
  pTemperatureWarningEvent EVENTFLAGS
  pMaxOverheatingOff Utenth
  pOverheatingOffEvent EVENTFLAGS
  pPowerCycleTime Unsigned32
  pExternalSensorLabel DisplayString
  pMaxOverheatingWarning Utenth
  pOverheatingWarningEvent EVENTFLAGS
  pMicroIntTimeThreshold Utenth
  pMicroIntEvent EVENTFLAGS
  pSoftFuseCurrentThreshold Unsigned32
  pSoftFuseDelay Unsigned32
  pSoftFuseEvent EVENTFLAGS
  pPhaseShiftEvent EVENTFLAGS
  pSchedulePortOnTime Unsigned32
  pSchedulePortOffTime Unsigned32
  pEnableSchedulePort Unsigned32
  pBlockSetPortOff Unsigned32
  pSchedulePortChangeEvent EVENTFLAGS
  pAgentIP IpAddress
  pAgentPort Unsigned32
  pAgentCommunicationEventFlags EVENTFLAGS
  pAlwaysOn Unsigned32
  pGenericTransducerParameters Integer32
  pMaxBigCurrentWarning Unsigned32
  pMaxBigPowerWarning Uthousandth
  pGroupNumber Unsigned32
  pPhaseLink Unsigned32
  pCurrentSensorSelector Unsigned32
  pMinBigCurrentWarning Unsigned32
  powerIndex Integer32
  powerModuleIndex Integer32

EESNEntry  
SEQUENCE    
  aGeneralModuleStatus Unsigned32
  aSpecificModuleStatus Unsigned32
  aCurrentTime TimeTicks
  aVoltage Uhundredth
  aStatePortCur CURPORTSTATE
  aTemperature Utenth
  aHumidity Utenth
  aAirflow Utenth
  aDewPoint Utenth
  aPressure Utenth
  aAnalogueInput Unsigned32
  aWaterleak Unsigned32
  aMotionDetected Unsigned32
  aIOPort Unsigned32
  aHighCurrent Stenth
  aHighPower Shundredth
  aModuleName DisplayString
  aFirmwareVersion Version
  aHardwareVersion Version
  aFirmwareID DisplayString
  aHardwareID DisplayString
  aDisplayTimeOn Unsigned32
  aMaxVoltageWarning Uhundredth
  aMinVoltageWarning Uhundredth
  aMinTemperatureWarning Utenth
  aMaxTemperatureWarning Utenth
  aMinHumidityWarning Utenth
  aMaxHumidityWarning Utenth
  aCurrentWarningEvent EVENTFLAGS
  aPowerWarningEvent EVENTFLAGS
  aVoltageWarningEvent EVENTFLAGS
  aTemperatureWarningEvent EVENTFLAGS
  aHumidityWarningEvent EVENTFLAGS
  aDewPointWarning Utenth
  aDewPointWarningEvent EVENTFLAGS
  aDewPointViolationEvent EVENTFLAGS
  aPressureWarningEvent EVENTFLAGS
  aMinPressureWarning Utenth
  aMaxPressureWarning Utenth
  aDisplayBrightness Unsigned32
  aMotionSensitivity Unsigned32
  aExternalSensorLabel DisplayString
  aRelayLabel DisplayString
  aMinAnalogueInputWarning Unsigned32
  aMaxAnalogueInputWarning Unsigned32
  aWaterleakWarning Unsigned32
  aMinAirflowWarning Unsigned32
  aMaxAirflowWarning Unsigned32
  aAnalogueInputWarningEvent EVENTFLAGS
  aWaterleakWarningEvent EVENTFLAGS
  aAirflowWarningEvent EVENTFLAGS
  aRelayAssertActionEvent EVENTFLAGS
  aRelayDeassertActionEvent EVENTFLAGS
  aMotionWarning Unsigned32
  aMotionWarningEvent EVENTFLAGS
  aDeviceID DisplayString
  aDeviceVersion Version
  aSysName DisplayString
  aMaxHighCurrentWarning Stenth
  aMinHighCurrentWarning Stenth
  aMinHighPowerWarning Shundredth
  aMaxHighPowerWarning Shundredth
  aIOPortWarningEvent EVENTFLAGS
  esnIndex Integer32
  esnModuleIndex Integer32

ETestModuleEntry  
SEQUENCE    
  yGeneralModuleStatus Unsigned32
  ySpecificModuleStatus Unsigned32
  yCurrentTime TimeTicks
  yCurrent Uthousandth
  yStatePortCur CURPORTSTATE
  yAnalogueInput Unsigned32
  yModuleName DisplayString
  yFirmwareVersion Version
  yHardwareVersion Version
  yFirmwareID DisplayString
  yHardwareID DisplayString
  testmoduleIndex Integer32
  testmoduleModuleIndex Integer32

EPCEntry  
SEQUENCE    
  uGeneralModuleStatus Unsigned32
  uSpecificModuleStatus Unsigned32
  uCurrentTime TimeTicks
  uVoltage Uhundredth
  uCurrent Uthousandth
  uStatePortCur CURPORTSTATE
  uTemperature Utenth
  uHumidity Utenth
  uModuleName DisplayString
  uFirmwareVersion Version
  uHardwareVersion Version
  uFirmwareID DisplayString
  uHardwareID DisplayString
  uPortState Unsigned32
  pcIndex Integer32
  pcModuleIndex Integer32

EEnergyMonitorEntry  
SEQUENCE    
  eGeneralModuleStatus Unsigned32
  eSpecificModuleStatus Unsigned32
  eCurrentTime TimeTicks
  eVoltage Uhundredth
  eFrequency Uthousandth
  eCurrent Uthousandth
  ePower Unsigned32
  eActiveEnergy Uthousandth
  eApparentEnergy Uthousandth
  eTemperature Utenth
  eApparentPower Unsigned32
  ePowerFactor Unsigned32
  eTotalCurrent Uthousandth
  eTotalRealPower Unsigned32
  eTotalApparentPower Unsigned32
  eTotalActiveEnergy Uthousandth
  eTotalApparentEnergy Uthousandth
  eTotalPowerFactor Unsigned32
  eTimeOnline Unsigned32
  eTotalHarmonicDistortion Utenth
  eModuleName DisplayString
  eFirmwareVersion Version
  eHardwareVersion Version
  eFirmwareID DisplayString
  eHardwareID DisplayString
  eMaxCurrentWarning Uthousandth
  eMaxPowerWarning Unsigned32
  eMaxTotalCurrentWarning Uthousandth
  eMaxTotalPowerWarning Unsigned32
  eMaxVoltageWarning Uhundredth
  eMinVoltageWarning Uhundredth
  eMinTemperatureWarning Utenth
  eMaxTemperatureWarning Utenth
  eCurrentWarningEvent EVENTFLAGS
  ePowerWarningEvent EVENTFLAGS
  eTotalCurrentWarningEvent EVENTFLAGS
  eTotalPowerWarningEvent EVENTFLAGS
  eVoltageWarningEvent EVENTFLAGS
  eTemperatureWarningEvent EVENTFLAGS
  eMicroIntTimeThreshold Utenth
  eMicroIntEvent EVENTFLAGS
  energymonitorIndex Integer32
  energymonitorModuleIndex Integer32

EThreePhasePowerEntry  
SEQUENCE    
  threephasepowerIndex Integer32
  threephasepowerModuleIndex Integer32

EMeasuring3PhaseEntry  
SEQUENCE    
  qGeneralModuleStatus Unsigned32
  qSpecificModuleStatus Unsigned32
  qCurrentTime TimeTicks
  qVoltage Uhundredth
  qFrequency Uthousandth
  qActiveEnergy Uthousandth
  qApparentEnergy Uthousandth
  qTemperature Utenth
  qPowerFactor Unsigned32
  qTimeOnline Unsigned32
  qIOPort Unsigned32
  qTotalHarmonicDistortion Utenth
  qPhase Unsigned32
  qBigCurrent Unsigned32
  qBigPower Uthousandth
  qBigApparentPower Uthousandth
  qStatus Unsigned32
  qModuleName DisplayString
  qFirmwareVersion Version
  qHardwareVersion Version
  qFirmwareID DisplayString
  qHardwareID DisplayString
  qPortState Unsigned32
  qMaxVoltageWarning Uhundredth
  qMinVoltageWarning Uhundredth
  qMinTemperatureWarning Utenth
  qMaxTemperatureWarning Utenth
  qPortStateEvent EVENTFLAGS
  qCurrentWarningEvent EVENTFLAGS
  qPowerWarningEvent EVENTFLAGS
  qVoltageWarningEvent EVENTFLAGS
  qTemperatureWarningEvent EVENTFLAGS
  qMicroIntTimeThreshold Utenth
  qMicroIntEvent EVENTFLAGS
  qDeviceID DisplayString
  qDeviceVersion Version
  qMaxBigCurrentWarning Unsigned32
  qMaxBigPowerWarning Uthousandth
  qCurrentSensorSelector Unsigned32
  qMinBigCurrentWarning Unsigned32
  qkWhMode Unsigned32
  measuring3phaseIndex Integer32
  measuring3phaseModuleIndex Integer32

EDisplayModuleEntry  
SEQUENCE    
  dGeneralModuleStatus Unsigned32
  dSpecificModuleStatus Unsigned32
  dCurrentTime TimeTicks
  dTemperature Utenth
  dTimeOnline Unsigned32
  dModuleName DisplayString
  dFirmwareVersion Version
  dHardwareVersion Version
  dFirmwareID DisplayString
  dHardwareID DisplayString
  dMinTemperatureWarning Utenth
  dMaxTemperatureWarning Utenth
  dDisplayAllDevices Unsigned32
  displaymoduleIndex Integer32
  displaymoduleModuleIndex Integer32

Defined Values

esRACKTIVITYMIB 1.3.6.1.4.1.34097.9
The MIB module for the Racktivity Devices
MODULE-IDENTITY    

racktivity 1.3.6.1.4.1.34097
OBJECT IDENTIFIER    

racktivityNotif 1.3.6.1.4.1.34097.9.0
OBJECT IDENTIFIER    

masterModule 1.3.6.1.4.1.34097.9.77
OBJECT IDENTIFIER    

eMasterTable 1.3.6.1.4.1.34097.9.77.1
NO_INFO
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    EMasterEntry

eMasterEntry 1.3.6.1.4.1.34097.9.77.1.1
NO_INFO
Status: current Access: not-accessible
OBJECT-TYPE    
  EMasterEntry  

masterIndex 1.3.6.1.4.1.34097.9.77.1.1.65537
Index for the selected Master Module
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..8  

masterModuleIndex 1.3.6.1.4.1.34097.9.77.1.1.65538
Selected Master Module
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..8  

mGeneralModuleStatus 1.3.6.1.4.1.34097.9.77.1.1.1
General status of a module.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

mSpecificModuleStatus 1.3.6.1.4.1.34097.9.77.1.1.2
Specific status of a module.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

mCurrentTime 1.3.6.1.4.1.34097.9.77.1.1.3
Gets or sets the current time (not possible when NTP is enabled). (unit: UNIX)
Status: current Access: read-write
OBJECT-TYPE    
  TimeTicks  

mVoltage 1.3.6.1.4.1.34097.9.77.1.1.4
Gets the voltage of a power module. (unit: 0.01V)
Status: current Access: read-only
OBJECT-TYPE    
  Uhundredth  

mTemperature 1.3.6.1.4.1.34097.9.77.1.1.11
Gets the current temperature of a temperature sensor. (unit: 0.1K)
Status: current Access: read-only
OBJECT-TYPE    
  Utenth  

mCurrentIP 1.3.6.1.4.1.34097.9.77.1.1.14
Gets the current IP address. To set the IP address, use IPADDR instead.
Status: current Access: read-only
OBJECT-TYPE    
  IpAddress  

mTotalCurrent 1.3.6.1.4.1.34097.9.77.1.1.17
Gets the total current of a power module. (unit: 0.001A)
Status: current Access: read-only
OBJECT-TYPE    
  Uthousandth  

mTotalRealPower 1.3.6.1.4.1.34097.9.77.1.1.18
Gets the total power level of a power module. (unit: W)
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

mTotalActiveEnergy 1.3.6.1.4.1.34097.9.77.1.1.20
Gets the total energy of a power module. (unit: 0.001kWh)
Status: current Access: read-only
OBJECT-TYPE    
  Uthousandth  

mLineCurrent 1.3.6.1.4.1.34097.9.77.1.1.32
Gets the current line current. (unit: 0.001A)
Status: current Access: read-only
OBJECT-TYPE    
  Uthousandth 0..65535  

mFuseCurrent 1.3.6.1.4.1.34097.9.77.1.1.33
Gets the current through a fuse. (unit: 0.001A)
Status: current Access: read-only
OBJECT-TYPE    
  Uthousandth 0..65535  

mCurrentSubNetMask 1.3.6.1.4.1.34097.9.77.1.1.34
Gets the current subnet mask. To set the subnet mask use SNMSK instead.
Status: current Access: read-only
OBJECT-TYPE    
  IpAddress  

mCurrentDNSServer 1.3.6.1.4.1.34097.9.77.1.1.35
Gets the current DNS server. To set the DNS server use DNSSRV instead.
Status: current Access: read-only
OBJECT-TYPE    
  IpAddress  

mCurrentStdGateway 1.3.6.1.4.1.34097.9.77.1.1.36
Gets the current standard gateway. To set the standard gateway use STDGW instead.
Status: current Access: read-only
OBJECT-TYPE    
  IpAddress  

mUPSPresent 1.3.6.1.4.1.34097.9.77.1.1.37
Checks if a UPS is present.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..1  

mUPSStatus 1.3.6.1.4.1.34097.9.77.1.1.38
Gets the working status of a UPS (if its working on its batteries or not).
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

mUPSEstimatedRunTime 1.3.6.1.4.1.34097.9.77.1.1.39
Gets the estimated run time of a UPS. (unit: min)
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..65535  

mUPSBatteryLevel 1.3.6.1.4.1.34097.9.77.1.1.40
The current UPS battery level. (unit: 0.1%)
Status: current Access: read-only
OBJECT-TYPE    
  Utenth 0..1000  

mHighCurrent 1.3.6.1.4.1.34097.9.77.1.1.41
The current for high values (unit: 0.1A)
Status: current Access: read-only
OBJECT-TYPE    
  Stenth  

mUpsCommunicationStatus 1.3.6.1.4.1.34097.9.77.1.1.42
Status information of communication with the UPS
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..1  

mHighPower 1.3.6.1.4.1.34097.9.77.1.1.43
The power for high values (unit: 0.01kW)
Status: current Access: read-only
OBJECT-TYPE    
  Shundredth -32768..32767  

mTotalHighCurrent 1.3.6.1.4.1.34097.9.77.1.1.44
The current for high values (unit: 0.1A)
Status: current Access: read-only
OBJECT-TYPE    
  Stenth 0..65535  

mTotalHighPower 1.3.6.1.4.1.34097.9.77.1.1.45
The power for high values (unit: 0.01kW)
Status: current Access: read-only
OBJECT-TYPE    
  Shundredth -32768..32767  

mPositiveEnergy 1.3.6.1.4.1.34097.9.77.1.1.46
Gets the positive energy used by an outlet. (unit: 0.001kWh)
Status: current Access: read-only
OBJECT-TYPE    
  Uthousandth 0..4294967295  

mNegativeEnergy 1.3.6.1.4.1.34097.9.77.1.1.47
Gets the negative energy used by an outlet. (unit: 0.001kWh)
Status: current Access: read-only
OBJECT-TYPE    
  Uthousandth 0..4294967295  

mTotalPositiveEnergy 1.3.6.1.4.1.34097.9.77.1.1.48
Gets the positive energy of the module. (unit: 0.001kWh)
Status: current Access: read-only
OBJECT-TYPE    
  Uthousandth 0..4294967295  

mTotalNegativeEnergy 1.3.6.1.4.1.34097.9.77.1.1.49
Gets the negative energy of the module. (unit: 0.001kWh)
Status: current Access: read-only
OBJECT-TYPE    
  Uthousandth 0..4294967295  

mCloudStatus 1.3.6.1.4.1.34097.9.77.1.1.56
Gets the status of the connection with the cloud. 0 = Idle state; 1 = Disabled; 2 = Initialising; 3 = Initialising - No connection; 4 = Initialising - No key; 5 = Connection Ok; 6 = Connection Failed; 7 = Connection Failed - No key.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..255  

mStatus 1.3.6.1.4.1.34097.9.77.1.1.1000
status of a module
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..65535  

mModuleName 1.3.6.1.4.1.34097.9.77.1.1.10001
Gets, sets or defaults the module name.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

mFirmwareVersion 1.3.6.1.4.1.34097.9.77.1.1.10002
Gets the version of the module's firmware.
Status: current Access: read-only
OBJECT-TYPE    
  Version  

mHardwareVersion 1.3.6.1.4.1.34097.9.77.1.1.10003
Gets the version of a module's hardware.
Status: current Access: read-only
OBJECT-TYPE    
  Version  

mFirmwareID 1.3.6.1.4.1.34097.9.77.1.1.10004
Gets the ID of the module's firmware.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

mHardwareID 1.3.6.1.4.1.34097.9.77.1.1.10005
Gets the ID of a module's hardware.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

mRackName 1.3.6.1.4.1.34097.9.77.1.1.10006
Gets, sets or defaults the name of the rack.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

mRackPosition 1.3.6.1.4.1.34097.9.77.1.1.10007
Gets, sets or defaults the position in the rack.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

mIPAddress 1.3.6.1.4.1.34097.9.77.1.1.10011
Gets, sets or defaults the IP address (when DHCP is disabled).
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

mSubNetMask 1.3.6.1.4.1.34097.9.77.1.1.10012
Gets, sets or defaults the subnet mask (when DHCP is disabled).
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

mStdGateWay 1.3.6.1.4.1.34097.9.77.1.1.10013
Gets, sets or defaults the standard gateway (when DHCP is disabled).
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

mDnsServer 1.3.6.1.4.1.34097.9.77.1.1.10014
Gets, sets or defaults the IP address of the used DNS server (when DHCP is disabled).
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

mMAC 1.3.6.1.4.1.34097.9.77.1.1.10015
Gets the MAC address of a master module.
Status: current Access: read-only
OBJECT-TYPE    
  MacAddress  

mDHCPEnable 1.3.6.1.4.1.34097.9.77.1.1.10016
Enables, disables or defaults DHCP. Set to 1 to enable DHCP, or 0 to disable DHCP.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..1  

mNTPServer 1.3.6.1.4.1.34097.9.77.1.1.10017
Gets, sets or defaults the NTP (Network Time Protocol) server IP address.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

mUseDefaultNTPServer 1.3.6.1.4.1.34097.9.77.1.1.10018
Enables, disables or defaults the usage of the default NTP (Network Time Protocol) server (pool.ntp.org).
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..1  

mUseNTP 1.3.6.1.4.1.34097.9.77.1.1.10019
Enables, disables or defaults NTP (Network Time Protocol). Set to 1 to enable NTP, or 0 to disable NTP.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..1  

mSNMPTrapRecvIP 1.3.6.1.4.1.34097.9.77.1.1.10020
Gets, sets or defaults the SNMP trap receiver IP address.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

mSNMPTrapRecvPort 1.3.6.1.4.1.34097.9.77.1.1.10021
Gets, sets or defaults the SNMP tap receiver port.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..65535  

mSNMPControl 1.3.6.1.4.1.34097.9.77.1.1.10024
Enables, disables or defaults write access over SNMP. Set to 1 to disable write access, or 0 to enable write access.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..1  

mECSServer 1.3.6.1.4.1.34097.9.77.1.1.10028
Gets, sets or defaults the ECS (Energy Cloud Sentinel) server IP address.
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

mUseECSServer 1.3.6.1.4.1.34097.9.77.1.1.10029
Enables, disables or defaults the use of an ECS (Energy Cloud Sentinel) server. Set to 1 to enable or 0 to disable.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..1  

mDisplayLock 1.3.6.1.4.1.34097.9.77.1.1.10031
Gets, sets or defaults the display lock. If the display is locked, you can still view information on the display, but you are not allowed to change settings through the menu system.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..255  

mDisplayTimeOn 1.3.6.1.4.1.34097.9.77.1.1.10032
Gets, sets or defaults the display sleep timer. If the display is inactive for longer than this time, the display turns off to save power. Time is in minutes. (unit: min)
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..255  

mMaxVoltageWarning 1.3.6.1.4.1.34097.9.77.1.1.10047
Gets, sets or defaults the maximum voltage warning level. (unit: 0.01V)
Status: current Access: read-write
OBJECT-TYPE    
  Uhundredth 0..65535  

mMinVoltageWarning 1.3.6.1.4.1.34097.9.77.1.1.10049
Gets, sets or defaults the minimum voltage warning level. (unit: 0.01V)
Status: current Access: read-write
OBJECT-TYPE    
  Uhundredth 0..65535  

mMinTemperatureWarning 1.3.6.1.4.1.34097.9.77.1.1.10052
Gets, sets or defaults the minimum temperature warning level (use DEF accessor to reset). (unit: 0.1K)
Status: current Access: read-write
OBJECT-TYPE    
  Utenth 2232..4732  

mMaxTemperatureWarning 1.3.6.1.4.1.34097.9.77.1.1.10053
Gets, sets or defaults the maximum temperature warning level (use DEF accessor to reset). (unit: 0.1K)
Status: current Access: read-write
OBJECT-TYPE    
  Utenth 2232..4732  

mGeneralEventEnable 1.3.6.1.4.1.34097.9.77.1.1.10074
Gets, sets or defaults general events. If set to 0, no events will be generated. Set to 1 to generate events on media indicated by the event bitfields.
Status: current Access: read-write
OBJECT-TYPE    
  EVENTFLAGS  

mSNMPSysContact 1.3.6.1.4.1.34097.9.77.1.1.10075
Gets, sets or defaults the SNMP contact information.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

mCurrentWarningEvent 1.3.6.1.4.1.34097.9.77.1.1.10078
Enables or disables the SNMP trap if the outlet current warning level is exceeded.
Status: current Access: read-write
OBJECT-TYPE    
  EVENTFLAGS  

mPowerWarningEvent 1.3.6.1.4.1.34097.9.77.1.1.10080
Enables or disables the SNMP trap if the power warning level is exceeded.
Status: current Access: read-write
OBJECT-TYPE    
  EVENTFLAGS  

mTotalCurrentWarningEvent 1.3.6.1.4.1.34097.9.77.1.1.10082
Enables or disables the SNMP trap if the total outlet current warning level is exceeded.
Status: current Access: read-write
OBJECT-TYPE    
  EVENTFLAGS  

mTotalPowerWarningEvent 1.3.6.1.4.1.34097.9.77.1.1.10084
Enables or disables the SNMP trap if the total power warning level is exceeded.
Status: current Access: read-write
OBJECT-TYPE    
  EVENTFLAGS  

mVoltageWarningEvent 1.3.6.1.4.1.34097.9.77.1.1.10086
Enables or disables the SNMP trap if the voltage warning level is exceeded.
Status: current Access: read-write
OBJECT-TYPE    
  EVENTFLAGS  

mTemperatureWarningEvent 1.3.6.1.4.1.34097.9.77.1.1.10087
Enables or disables the SNMP trap if the temperature warning level is exceeded.
Status: current Access: read-write
OBJECT-TYPE    
  EVENTFLAGS  

mDisplayBrightness 1.3.6.1.4.1.34097.9.77.1.1.10098
Gets, sets or defaults the display brightness (if supported).
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..255  

mECSServerPort 1.3.6.1.4.1.34097.9.77.1.1.10106
Gets, sets or defaults the ECS (Energy Cloud Sentinel) server port.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..65535  

mExternalSensorLabel 1.3.6.1.4.1.34097.9.77.1.1.10109
Gets, sets or defaults the external sensor label. External sensors can be connected to Energy Sensors.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

mHttpsOnly 1.3.6.1.4.1.34097.9.77.1.1.10127
Enables or disables the use of HTTPS (secure HTTP). Set to 1 to enable HTTPS only, or 0 to also enable HTTP.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..1  

mTelnetSsl 1.3.6.1.4.1.34097.9.77.1.1.10128
Enables or disables the use of Telnet SSL (secure Telnet). Set to 1 to enable Telnet SSL, or 0 to disable Telnet SSL).
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..1  

mCookieTimeToLive 1.3.6.1.4.1.34097.9.77.1.1.10130
The TTL (Time To Live) of the website cookie. (unit: min)
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..65535  

mLineCurrentWarningThreshold 1.3.6.1.4.1.34097.9.77.1.1.10131
Gets, sets the warning threshold of the linecurrent. (unit: 0.001A)
Status: current Access: read-write
OBJECT-TYPE    
  Uthousandth 0..65535  

mLineCurrentOffThreshold 1.3.6.1.4.1.34097.9.77.1.1.10132
Gets, sets the off threshold of the linecurrent. (unit: 0.001A)
Status: current Access: read-write
OBJECT-TYPE    
  Uthousandth 0..65535  

mLineCurrentWarningEvent 1.3.6.1.4.1.34097.9.77.1.1.10133
Enables or disables the SNMP trap if the linecurrent warning level is exceeded.
Status: current Access: read-write
OBJECT-TYPE    
  EVENTFLAGS  

mLineCurrentOffEvent 1.3.6.1.4.1.34097.9.77.1.1.10134
Enables or disables the SNMP trap if the linecurrent off level is exceeded.
Status: current Access: read-write
OBJECT-TYPE    
  EVENTFLAGS  

mFuseCurrentWarningThreshold 1.3.6.1.4.1.34097.9.77.1.1.10142
Gets, sets or defaults the maximum current warning threshold per fuse. (unit: 0.001A)
Status: current Access: read-write
OBJECT-TYPE    
  Uthousandth 0..32000  

mFuseCurrentOffThreshold 1.3.6.1.4.1.34097.9.77.1.1.10143
Gets, sets or defaults the maximum current off threshold per fuse. (unit: 0.001A)
Status: current Access: read-write
OBJECT-TYPE    
  Uthousandth 0..32000  

mFuseCurrentWarningEvent 1.3.6.1.4.1.34097.9.77.1.1.10144
Enables or disables the SNMP trap if the fusecurrent warning threshold is exceeded.
Status: current Access: read-write
OBJECT-TYPE    
  EVENTFLAGS  

mFuseCurrentOffEvent 1.3.6.1.4.1.34097.9.77.1.1.10145
Enables or disables the SNMP trap if the fusecurrent off threshold is exceeded.
Status: current Access: read-write
OBJECT-TYPE    
  EVENTFLAGS  

mDeviceID 1.3.6.1.4.1.34097.9.77.1.1.10150
The ID of the device.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

mDeviceVersion 1.3.6.1.4.1.34097.9.77.1.1.10151
The version of the device.
Status: current Access: read-only
OBJECT-TYPE    
  Version  

mSysName 1.3.6.1.4.1.34097.9.77.1.1.10152
The full name of the device.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

mElectricalTopology 1.3.6.1.4.1.34097.9.77.1.1.10153
Gets the electrical topology of the unit.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..2  

mFusePortTopology 1.3.6.1.4.1.34097.9.77.1.1.10154
Gets the topology between the outlets and fuses.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..6  

mLineFuseTopology 1.3.6.1.4.1.34097.9.77.1.1.10155
Gets the topology between the inlet (cable or connection) and the fuses.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..3  

mSSOIPAddress 1.3.6.1.4.1.34097.9.77.1.1.10156
Gets, sets the IP address of an SSO (Smart Style Office).
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

mSSOLoginCredentials 1.3.6.1.4.1.34097.9.77.1.1.10157
Gets, sets the login credentials of an SSO (Smart Style Office).
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

mSSOGracefullShutdown 1.3.6.1.4.1.34097.9.77.1.1.10158
Gets, sets the string to send if the UPS' battery level is below the set threshold.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

mUPSWarningLevel 1.3.6.1.4.1.34097.9.77.1.1.10159
Gets, sets or defaults the graceful shutdown threshold of a UPS.
Status: current Access: read-write
OBJECT-TYPE    
  Utenth 0..1000  

mUPSOffLevel 1.3.6.1.4.1.34097.9.77.1.1.10160
Gets, sets or defaults the threshold of a UPS to set outlets off.
Status: current Access: read-write
OBJECT-TYPE    
  Utenth 0..1000  

mMaxHighCurrentWarning 1.3.6.1.4.1.34097.9.77.1.1.10165
Gets sets or defaults the maximum high current warning level. (unit: 0.1A)
Status: current Access: read-write
OBJECT-TYPE    
  Stenth -32768..32767  

mUpsMonitoringProtocol 1.3.6.1.4.1.34097.9.77.1.1.10167
Disables/Enables UPS monitoring and selects the protocol used for UPS monitoring. 0 = Disabled; 1 = Use old APC protocol
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..1  

mUpsEmergencyThreshold 1.3.6.1.4.1.34097.9.77.1.1.10168
When the UPS battery level goes below this threshold a shutdown request will be sent to all agents (unit: 0.1%)
Status: current Access: read-write
OBJECT-TYPE    
  Utenth 0..1000  

mUpsRecoveryThreshold 1.3.6.1.4.1.34097.9.77.1.1.10169
When the UPS battery level goes above this threshold a outlets will be powered on as configured by the user (unit: 0.1%)
Status: current Access: read-write
OBJECT-TYPE    
  Utenth 0..1000  

mUpsEventFlags 1.3.6.1.4.1.34097.9.77.1.1.10170
Event flags for events related to the UPS monitoring
Status: current Access: read-write
OBJECT-TYPE    
  EVENTFLAGS  

mRecoveryPowerThreshold 1.3.6.1.4.1.34097.9.77.1.1.10171
When the UPS was on battery and it went below UPSEMERGTHRES, the outlets that have a load below the RECOVPOWERTHRES will be power cycled once the UPS is back on mains power and exceeds UPSRECOVTHRES (unit: W)
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 20..4000  

mMinHighCurrentWarning 1.3.6.1.4.1.34097.9.77.1.1.10176
Gets sets or defaults the minimum high current warning level. (unit: 0.1A)
Status: current Access: read-write
OBJECT-TYPE    
  Stenth -32768..32767  

mMinHighPowerWarning 1.3.6.1.4.1.34097.9.77.1.1.10177
Gets sets or defaults the power min high current warning level. (unit: 0.01kW)
Status: current Access: read-write
OBJECT-TYPE    
  Shundredth -32768..32767  

mMaxHighPowerWarning 1.3.6.1.4.1.34097.9.77.1.1.10178
Gets sets or defaults the power max high current warning level. (unit: 0.01kW)
Status: current Access: read-write
OBJECT-TYPE    
  Shundredth -32768..32767  

mHeartbeatInterval 1.3.6.1.4.1.34097.9.77.1.1.10179
Interval (in seconds) between 2 heartbeat SNMP traps, Set to 0 to disable (unit: s)
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..255  

mMinTotalHighCurrentWarning 1.3.6.1.4.1.34097.9.77.1.1.10180
Gets sets or defaults the maximum high current warning level. (unit: 0.1A)
Status: current Access: read-write
OBJECT-TYPE    
  Stenth -32768..32767  

mMaxTotalHighCurrentWarning 1.3.6.1.4.1.34097.9.77.1.1.10181
Gets sets or defaults the maximum high current warning level. (unit: 0.1A)
Status: current Access: read-write
OBJECT-TYPE    
  Stenth -32768..32767  

mMinTotalHighPowerWarning 1.3.6.1.4.1.34097.9.77.1.1.10182
Gets sets or defaults the power min high current warning level. (unit: 0.01kW)
Status: current Access: read-write
OBJECT-TYPE    
  Shundredth -32768..32767  

mMaxTotalHighPowerWarning 1.3.6.1.4.1.34097.9.77.1.1.10183
Gets sets or defaults the power max high current warning level. (unit: 0.01kW)
Status: current Access: read-write
OBJECT-TYPE    
  Shundredth -32768..32767  

mCloudState 1.3.6.1.4.1.34097.9.77.1.1.10208
Set if the device needs to push info to the init cloud (val=0) or to the normal cloud (val=1)
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..2  

mSensorBias 1.3.6.1.4.1.34097.9.77.1.1.10210
get or set the DC sensor bias (unit: mV)
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -32768..32767  

mDaisyChainDeviceMode 1.3.6.1.4.1.34097.9.77.1.1.10211
allowed modes: 0: standalone (master without daisy chain slaves) 1: daisy chain master 2: daisy chain slave 1 3: daisy chain slave 2 4: daisy chain slave 3
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..4  

mSNMPTrapUser 1.3.6.1.4.1.34097.9.77.1.1.10212
Gets, sets or defaults the SNMP tap user out of the user list.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..4  

mUSMUser 1.3.6.1.4.1.34097.9.77.1.1.10213
Gets, sets or defaults the SNMP USM security user
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

mUSMAuthPassphrase 1.3.6.1.4.1.34097.9.77.1.1.10214
Gets, sets or defaults the SNMP USM authentication passphrase (Always MD5)
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

mUSMPrivPassphrase 1.3.6.1.4.1.34097.9.77.1.1.10215
Gets, sets or defaults the SNMP USM private passphrase (Always AES)
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

mSNMPV2GetSetEnable 1.3.6.1.4.1.34097.9.77.1.1.10216
Gets, sets or defaults the SNMP V2 Enable for get ,set or walk but not for traps.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..1  

mSNMPV3GetSetEnable 1.3.6.1.4.1.34097.9.77.1.1.10217
Gets, sets or defaults the SNMP V3 Enable for get ,set or walk but not for traps.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..1  

mUSMAuthPassphraseLength 1.3.6.1.4.1.34097.9.77.1.1.10218
Gets, sets or defaults the SNMP USM authentication passphrase length
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..16  

mUSMPrivPassphraseLength 1.3.6.1.4.1.34097.9.77.1.1.10219
Gets, sets or defaults the SNMP USM private passphrase length
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..16  

mSNMPTrapEnable 1.3.6.1.4.1.34097.9.77.1.1.10222
Gets, sets or defaults the SNMP Trap Enable per trap account
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..1  

mLDAPAttribute 1.3.6.1.4.1.34097.9.77.1.1.10227
Attribute linked to the LDAPFilter
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

mLDAPPath 1.3.6.1.4.1.34097.9.77.1.1.10228
Relative Path to be used for the LDAPFilter
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

mLDAPAdminGroupName 1.3.6.1.4.1.34097.9.77.1.1.10229
GroupName for Admin Credentials in LDAP
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

mLDAPRestrictedGroupName 1.3.6.1.4.1.34097.9.77.1.1.10230
GroupName for Restricted Credentials in LDAP
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

mLDAPGuestGroupName 1.3.6.1.4.1.34097.9.77.1.1.10231
GroupName for Guest Credentials in LDAP
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

mLDAPEnable 1.3.6.1.4.1.34097.9.77.1.1.10232
Enable or disable login via LDAP credentials
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..1  

mLDAPLoginWrapper 1.3.6.1.4.1.34097.9.77.1.1.10233
Wrapper for login in with LDAP
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

mLDAPServer 1.3.6.1.4.1.34097.9.77.1.1.10235
NO_INFO
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

mLocalAuthEnable 1.3.6.1.4.1.34097.9.77.1.1.10236
Set if local authentication is still possible if LDAP is enabled
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..1  

powerModule 1.3.6.1.4.1.34097.9.80
OBJECT IDENTIFIER    

ePowerTable 1.3.6.1.4.1.34097.9.80.1
NO_INFO
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    EPowerEntry

ePowerEntry 1.3.6.1.4.1.34097.9.80.1.1
NO_INFO
Status: current Access: not-accessible
OBJECT-TYPE    
  EPowerEntry  

powerIndex 1.3.6.1.4.1.34097.9.80.1.1.65537
Index for the selected Power Module
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..8  

powerModuleIndex 1.3.6.1.4.1.34097.9.80.1.1.65538
Selected Power Module
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..8  

pGeneralModuleStatus 1.3.6.1.4.1.34097.9.80.1.1.1
General status of a module.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

pSpecificModuleStatus 1.3.6.1.4.1.34097.9.80.1.1.2
Specific status of a module.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

pCurrentTime 1.3.6.1.4.1.34097.9.80.1.1.3
Gets or sets the current time (not possible when NTP is enabled). (unit: UNIX)
Status: current Access: read-write
OBJECT-TYPE    
  TimeTicks  

pVoltage 1.3.6.1.4.1.34097.9.80.1.1.4
Gets the voltage of a power module. (unit: 0.01V)
Status: current Access: read-only
OBJECT-TYPE    
  Uhundredth  

pFrequency 1.3.6.1.4.1.34097.9.80.1.1.5
Gets the frequency of the input voltage of a power module. (unit: 0.001Hz)
Status: current Access: read-only
OBJECT-TYPE    
  Uthousandth  

pCurrent 1.3.6.1.4.1.34097.9.80.1.1.6
Gets the current of an outlet. (unit: 0.001A)
Status: current Access: read-only
OBJECT-TYPE    
  Uthousandth  

pPower 1.3.6.1.4.1.34097.9.80.1.1.7
Gets the power of an outlet. (unit: W)
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

pStatePortCur 1.3.6.1.4.1.34097.9.80.1.1.8
Gets the current state of an outlet. To toggle an outlet use PORTSTAT (CLI) or pPortstate (SNMP) (GUID 10035) instead.
Status: current Access: read-only
OBJECT-TYPE    
  CURPORTSTATE  

pActiveEnergy 1.3.6.1.4.1.34097.9.80.1.1.9
Gets the energy used by an outlet. (unit: 0.001kWh)
Status: current Access: read-only
OBJECT-TYPE    
  Uthousandth  

pApparentEnergy 1.3.6.1.4.1.34097.9.80.1.1.10
Gets the apparent energy used by an outlet. (unit: 0.001kVAh)
Status: current Access: read-only
OBJECT-TYPE    
  Uthousandth  

pTemperature 1.3.6.1.4.1.34097.9.80.1.1.11
Gets the current temperature of a temperature sensor. (unit: 0.1K)
Status: current Access: read-only
OBJECT-TYPE    
  Utenth  

pApparentPower 1.3.6.1.4.1.34097.9.80.1.1.15
Gets the apparent power of an outlet. (unit: VA)
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

pPowerFactor 1.3.6.1.4.1.34097.9.80.1.1.16
Gets the power factor of an outlet. (unit: %)
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

pTotalCurrent 1.3.6.1.4.1.34097.9.80.1.1.17
Gets the total current of a power module. (unit: 0.001A)
Status: current Access: read-only
OBJECT-TYPE    
  Uthousandth  

pTotalRealPower 1.3.6.1.4.1.34097.9.80.1.1.18
Gets the total power level of a power module. (unit: W)
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

pTotalApparentPower 1.3.6.1.4.1.34097.9.80.1.1.19
Gets the total apparent power of a power module. (unit: VA)
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

pTotalActiveEnergy 1.3.6.1.4.1.34097.9.80.1.1.20
Gets the total energy of a power module. (unit: 0.001kWh)
Status: current Access: read-only
OBJECT-TYPE    
  Uthousandth  

pTotalApparentEnergy 1.3.6.1.4.1.34097.9.80.1.1.21
Gets the total apparent energy of a power module. (unit: 0.001kVAh)
Status: current Access: read-only
OBJECT-TYPE    
  Uthousandth  

pTotalPowerFactor 1.3.6.1.4.1.34097.9.80.1.1.22
Gets the total power factor of a power module. (unit: %)
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

pTimeOnline 1.3.6.1.4.1.34097.9.80.1.1.24
Gets the amount of seconds since the last reset. (unit: s)
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

pTotalHarmonicDistortion 1.3.6.1.4.1.34097.9.80.1.1.50
total harmonic distortion - outlet (unit: 0.1%)
Status: current Access: read-only
OBJECT-TYPE    
  Utenth 0..1000  

pPhase 1.3.6.1.4.1.34097.9.80.1.1.51
the phase between 2 waves (unit: degr)
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..65535  

pBigCurrent 1.3.6.1.4.1.34097.9.80.1.1.52
Gets the current of an outlet. (unit: 0.0001A)
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

pBigPower 1.3.6.1.4.1.34097.9.80.1.1.53
Gets the power of an outlet. (unit: 0.001W)
Status: current Access: read-only
OBJECT-TYPE    
  Uthousandth  

pBigApparentPower 1.3.6.1.4.1.34097.9.80.1.1.54
Gets the apparent power of an outlet. (unit: 0.001VA)
Status: current Access: read-only
OBJECT-TYPE    
  Uthousandth  

pDetectedPhase 1.3.6.1.4.1.34097.9.80.1.1.55
Gives the best matching Phase per currentsensor. Updated every 8s. returnes 255 if no good phaselink is found
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..255  

pModuleName 1.3.6.1.4.1.34097.9.80.1.1.10001
Gets, sets or defaults the module name.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

pFirmwareVersion 1.3.6.1.4.1.34097.9.80.1.1.10002
Gets the version of the module's firmware.
Status: current Access: read-only
OBJECT-TYPE    
  Version  

pHardwareVersion 1.3.6.1.4.1.34097.9.80.1.1.10003
Gets the version of a module's hardware.
Status: current Access: read-only
OBJECT-TYPE    
  Version  

pFirmwareID 1.3.6.1.4.1.34097.9.80.1.1.10004
Gets the ID of the module's firmware.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

pHardwareID 1.3.6.1.4.1.34097.9.80.1.1.10005
Gets the ID of a module's hardware.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

pPortName 1.3.6.1.4.1.34097.9.80.1.1.10034
Gets, sets or defaults the name of an outlet.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

pPortState 1.3.6.1.4.1.34097.9.80.1.1.10035
Sets the state of an outlet: 0=OFF, 1=ON, 2=POWER CYCLE. To get the state of an outlet use CPORTSTAT (CLI) or pStatePortCur (SNMP) (GUID 8) instead.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..2  

pCurrentPriorOff 1.3.6.1.4.1.34097.9.80.1.1.10036
Gets, sets or defaults the priority of an outlet. Priority settings are used when 1 or more outlets must be turned off because the total current of a power module was exceeded.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 1..8  

pDelayOn 1.3.6.1.4.1.34097.9.80.1.1.10037
Gets, sets or defaults the outlet turn-on delay. Use this to reduce inrush current when the Energy Switch boots. (unit: s)
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..65535  

pMaxCurrentOff 1.3.6.1.4.1.34097.9.80.1.1.10038
Gets, sets or defaults the maximum current off level of an outlet. (unit: 0.001A)
Status: current Access: read-write
OBJECT-TYPE    
  Uthousandth 100..8000  

pMaxCurrentWarning 1.3.6.1.4.1.34097.9.80.1.1.10039
Gets, sets or defaults the maximum current warning level of an outlet. (unit: 0.001A)
Status: current Access: read-write
OBJECT-TYPE    
  Uthousandth 100..8000  

pMaxPowerOff 1.3.6.1.4.1.34097.9.80.1.1.10040
Gets, sets or defaults the maximum power off level of an outlet. (unit: W)
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 20..2000  

pMaxPowerWarning 1.3.6.1.4.1.34097.9.80.1.1.10041
Gets, sets or defaults the maximum power warning level of an outlet. (unit: W)
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 20..2000  

pMaxTotalCurrentOff 1.3.6.1.4.1.34097.9.80.1.1.10042
Gets, sets or defaults the total maximum current off level of a power module. (unit: 0.001A)
Status: current Access: read-write
OBJECT-TYPE    
  Uthousandth 100..16000  

pMaxTotalCurrentWarning 1.3.6.1.4.1.34097.9.80.1.1.10043
Gets, sets or defaults the total maximum current warning level of a power module. (unit: 0.001A)
Status: current Access: read-write
OBJECT-TYPE    
  Uthousandth 100..16000  

pMaxTotalPowerOff 1.3.6.1.4.1.34097.9.80.1.1.10044
Gets, sets or defaults the maximum total power off level. (unit: W)
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 20..4000  

pMaxTotalPowerWarning 1.3.6.1.4.1.34097.9.80.1.1.10045
Gets, sets or defaults the maximum total power warning level. (unit: W)
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 20..4000  

pMaxVoltageWarning 1.3.6.1.4.1.34097.9.80.1.1.10047
Gets, sets or defaults the maximum voltage warning level. (unit: 0.01V)
Status: current Access: read-write
OBJECT-TYPE    
  Uhundredth 5000..30000  

pMinVoltageWarning 1.3.6.1.4.1.34097.9.80.1.1.10049
Gets, sets or defaults the minimum voltage warning level. (unit: 0.01V)
Status: current Access: read-write
OBJECT-TYPE    
  Uhundredth 5000..30000  

pMinTemperatureWarning 1.3.6.1.4.1.34097.9.80.1.1.10052
Gets, sets or defaults the minimum temperature warning level (use DEF accessor to reset). (unit: 0.1K)
Status: current Access: read-write
OBJECT-TYPE    
  Utenth 2232..4732  

pMaxTemperatureWarning 1.3.6.1.4.1.34097.9.80.1.1.10053
Gets, sets or defaults the maximum temperature warning level (use DEF accessor to reset). (unit: 0.1K)
Status: current Access: read-write
OBJECT-TYPE    
  Utenth 2232..4732  

pPortStateEvent 1.3.6.1.4.1.34097.9.80.1.1.10076
Enables or disables the SNMP trap if the state of an outlet is changed.
Status: current Access: read-write
OBJECT-TYPE    
  EVENTFLAGS  

pCurrentOffEvent 1.3.6.1.4.1.34097.9.80.1.1.10077
Enables or disables the SNMP trap if the outlet current off level is exceeded.
Status: current Access: read-write
OBJECT-TYPE    
  EVENTFLAGS  

pCurrentWarningEvent 1.3.6.1.4.1.34097.9.80.1.1.10078
Enables or disables the SNMP trap if the outlet current warning level is exceeded.
Status: current Access: read-write
OBJECT-TYPE    
  EVENTFLAGS  

pPowerOffEvent 1.3.6.1.4.1.34097.9.80.1.1.10079
Enables or disables the SNMP trap if the power off level is exceeded.
Status: current Access: read-write
OBJECT-TYPE    
  EVENTFLAGS  

pPowerWarningEvent 1.3.6.1.4.1.34097.9.80.1.1.10080
Enables or disables the SNMP trap if the power warning level is exceeded.
Status: current Access: read-write
OBJECT-TYPE    
  EVENTFLAGS  

pTotalCurrentOffEvent 1.3.6.1.4.1.34097.9.80.1.1.10081
Enables or disables the SNMP trap if the total outlet current off level is exceeded.
Status: current Access: read-write
OBJECT-TYPE    
  EVENTFLAGS  

pTotalCurrentWarningEvent 1.3.6.1.4.1.34097.9.80.1.1.10082
Enables or disables the SNMP trap if the total outlet current warning level is exceeded.
Status: current Access: read-write
OBJECT-TYPE    
  EVENTFLAGS  

pTotalPowerOffEvent 1.3.6.1.4.1.34097.9.80.1.1.10083
Enables or disables the SNMP trap if the total power off level is exceeded.
Status: current Access: read-write
OBJECT-TYPE    
  EVENTFLAGS  

pTotalPowerWarningEvent 1.3.6.1.4.1.34097.9.80.1.1.10084
Enables or disables the SNMP trap if the total power warning level is exceeded.
Status: current Access: read-write
OBJECT-TYPE    
  EVENTFLAGS  

pVoltageWarningEvent 1.3.6.1.4.1.34097.9.80.1.1.10086
Enables or disables the SNMP trap if the voltage warning level is exceeded.
Status: current Access: read-write
OBJECT-TYPE    
  EVENTFLAGS  

pTemperatureWarningEvent 1.3.6.1.4.1.34097.9.80.1.1.10087
Enables or disables the SNMP trap if the temperature warning level is exceeded.
Status: current Access: read-write
OBJECT-TYPE    
  EVENTFLAGS  

pMaxOverheatingOff 1.3.6.1.4.1.34097.9.80.1.1.10090
Gets, sets or defaults the maximum overheat temperature off level. (unit: 0.1K)
Status: current Access: read-write
OBJECT-TYPE    
  Utenth 2232..4732  

pOverheatingOffEvent 1.3.6.1.4.1.34097.9.80.1.1.10091
Enables or disables the SNMP trap if the overtemperature off level is exceeded.
Status: current Access: read-write
OBJECT-TYPE    
  EVENTFLAGS  

pPowerCycleTime 1.3.6.1.4.1.34097.9.80.1.1.10099
Gets, sets or defaults the time interval that is used to do a power cycle of an outlet. (unit: s)
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..255  

pExternalSensorLabel 1.3.6.1.4.1.34097.9.80.1.1.10109
Gets, sets or defaults the external sensor label. External sensors can be connected to Energy Sensors.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

pMaxOverheatingWarning 1.3.6.1.4.1.34097.9.80.1.1.10121
Gets, sets or defaults the overheating temperature warning level. (unit: 0.1K)
Status: current Access: read-write
OBJECT-TYPE    
  Utenth 2232..4732  

pOverheatingWarningEvent 1.3.6.1.4.1.34097.9.80.1.1.10122
Enables or disables the SNMP trap if the overheat warning level is exceeded.
Status: current Access: read-write
OBJECT-TYPE    
  EVENTFLAGS  

pMicroIntTimeThreshold 1.3.6.1.4.1.34097.9.80.1.1.10135
The minimum time the voltage must be interrupted before it is seen as a micro interruption (unit: 0.1ms)
Status: current Access: read-write
OBJECT-TYPE    
  Utenth 10..65535  

pMicroIntEvent 1.3.6.1.4.1.34097.9.80.1.1.10136
Enables or disables the SNMP trap if a microinterruption on the voltage is detected.
Status: current Access: read-write
OBJECT-TYPE    
  EVENTFLAGS  

pSoftFuseCurrentThreshold 1.3.6.1.4.1.34097.9.80.1.1.10137
The threshold of the soft fuse is a factor of the maximum nominal current off (unit: A)
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..255  

pSoftFuseDelay 1.3.6.1.4.1.34097.9.80.1.1.10138
The minimum time the current of an outlet must be above the soft fuse current threshold to switch it off. (unit: ms)
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..65535  

pSoftFuseEvent 1.3.6.1.4.1.34097.9.80.1.1.10139
Enables or disables the SNMP trap if a soft fuse is triggered.
Status: current Access: read-write
OBJECT-TYPE    
  EVENTFLAGS  

pPhaseShiftEvent 1.3.6.1.4.1.34097.9.80.1.1.10140
Enables or disables the SNMP trap if a phase shift on the voltage is detected.
Status: current Access: read-write
OBJECT-TYPE    
  EVENTFLAGS  

pSchedulePortOnTime 1.3.6.1.4.1.34097.9.80.1.1.10146
Gets, sets or defaults the time for the scheduler to turn on an outlet. (unit: min)
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..1439  

pSchedulePortOffTime 1.3.6.1.4.1.34097.9.80.1.1.10147
Gets, sets or defaults the time for the scheduler to turn off an outlet. (unit: min)
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..1439  

pEnableSchedulePort 1.3.6.1.4.1.34097.9.80.1.1.10148
Enables or disables the scheduler on an outlet. When enabled the scheduling is repeated daily.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..1  

pBlockSetPortOff 1.3.6.1.4.1.34097.9.80.1.1.10161
Prevent outlets to be set off (only delay on and powercycle are still possible).
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..1  

pSchedulePortChangeEvent 1.3.6.1.4.1.34097.9.80.1.1.10166
event if a port has changed state because of the scheduler
Status: current Access: read-write
OBJECT-TYPE    
  EVENTFLAGS  

pAgentIP 1.3.6.1.4.1.34097.9.80.1.1.10172
IP address of the agent associated to this outlet
Status: current Access: read-write
OBJECT-TYPE    
  IpAddress  

pAgentPort 1.3.6.1.4.1.34097.9.80.1.1.10173
Network port on which the associated agent will listen
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..65535  

pAgentCommunicationEventFlags 1.3.6.1.4.1.34097.9.80.1.1.10174
Event flags for events related to agent communication
Status: current Access: read-write
OBJECT-TYPE    
  EVENTFLAGS  

pAlwaysOn 1.3.6.1.4.1.34097.9.80.1.1.10175
Outlets marked as Always On can only be power cycled by the user
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..1  

pGenericTransducerParameters 1.3.6.1.4.1.34097.9.80.1.1.10190
sets the slope of the transducer transfer function when the generic transducer type is selected (unit: mA/V)
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 2000..2000000000  

pMaxBigCurrentWarning 1.3.6.1.4.1.34097.9.80.1.1.10193
Gets, sets or defaults the maximum current warning level of an outlet. (unit: 0.0001A)
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 100..400000000  

pMaxBigPowerWarning 1.3.6.1.4.1.34097.9.80.1.1.10194
Gets, sets or defaults the maximum power warning level of an outlet. (unit: 0.001W)
Status: current Access: read-write
OBJECT-TYPE    
  Uthousandth 2000..2000000000  

pGroupNumber 1.3.6.1.4.1.34097.9.80.1.1.10195
Group number per port to group ports
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..5  


pCurrentSensorSelector 1.3.6.1.4.1.34097.9.80.1.1.10197
Selection of the currentsensor connected to port. To enter your own value you need to use 255 and fill in guid 10190.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..255  

pMinBigCurrentWarning 1.3.6.1.4.1.34097.9.80.1.1.10209
Gets, sets or defaults the minimum current warning level of a port. (unit: 0.0001A)
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..400000000  

esnModule 1.3.6.1.4.1.34097.9.65
OBJECT IDENTIFIER    

eESNTable 1.3.6.1.4.1.34097.9.65.1
Temperature Humidity Presure Airflow Waterleak
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    EESNEntry

eESNEntry 1.3.6.1.4.1.34097.9.65.1.1
Temperature Humidity Presure Airflow Waterleak
Status: current Access: not-accessible
OBJECT-TYPE    
  EESNEntry  

esnIndex 1.3.6.1.4.1.34097.9.65.1.1.65537
Index for the selected ESN Module
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..8  

esnModuleIndex 1.3.6.1.4.1.34097.9.65.1.1.65538
Selected ESN Module
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..8  

aGeneralModuleStatus 1.3.6.1.4.1.34097.9.65.1.1.1
General status of a module.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

aSpecificModuleStatus 1.3.6.1.4.1.34097.9.65.1.1.2
Specific status of a module.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

aCurrentTime 1.3.6.1.4.1.34097.9.65.1.1.3
Gets or sets the current time (not possible when NTP is enabled). (unit: UNIX)
Status: current Access: read-write
OBJECT-TYPE    
  TimeTicks  

aVoltage 1.3.6.1.4.1.34097.9.65.1.1.4
Gets the voltage of a power module. (unit: 0.01V)
Status: current Access: read-only
OBJECT-TYPE    
  Uhundredth  

aStatePortCur 1.3.6.1.4.1.34097.9.65.1.1.8
Gets the current state of an outlet. To toggle an outlet use PORTSTAT (CLI) or pPortstate (SNMP) (GUID 10035) instead.
Status: current Access: read-only
OBJECT-TYPE    
  CURPORTSTATE  

aTemperature 1.3.6.1.4.1.34097.9.65.1.1.11
Gets the current temperature of a temperature sensor. (unit: 0.1K)
Status: current Access: read-only
OBJECT-TYPE    
  Utenth  

aHumidity 1.3.6.1.4.1.34097.9.65.1.1.12
Gets the relative humidity. (unit: 0.1RH)
Status: current Access: read-only
OBJECT-TYPE    
  Utenth  

aAirflow 1.3.6.1.4.1.34097.9.65.1.1.23
Gets the current airflow level. (unit: 0.1m/s)
Status: current Access: read-only
OBJECT-TYPE    
  Utenth  

aDewPoint 1.3.6.1.4.1.34097.9.65.1.1.25
Gets the current dewpoint. Taking the current humidity into consideration, condensation will occur if the temperature drops below this level. (unit: 0.1K)
Status: current Access: read-only
OBJECT-TYPE    
  Utenth 0..65535  

aPressure 1.3.6.1.4.1.34097.9.65.1.1.26
Gets the atmospheric pressure. (unit: 0.1hPa)
Status: current Access: read-only
OBJECT-TYPE    
  Utenth  

aAnalogueInput 1.3.6.1.4.1.34097.9.65.1.1.27
Gets the value of an analog input (voltage). (unit: mV)
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

aWaterleak 1.3.6.1.4.1.34097.9.65.1.1.28
Gets the current state of the water leak sensor.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

aMotionDetected 1.3.6.1.4.1.34097.9.65.1.1.29
Gets or resets whether motion has been detected.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

aIOPort 1.3.6.1.4.1.34097.9.65.1.1.30
Gets the state of a digital input.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..1  

aHighCurrent 1.3.6.1.4.1.34097.9.65.1.1.41
The current for high values (unit: 0.1A)
Status: current Access: read-only
OBJECT-TYPE    
  Stenth -32768..32767  

aHighPower 1.3.6.1.4.1.34097.9.65.1.1.43
The power for high values (unit: 0.01kW)
Status: current Access: read-only
OBJECT-TYPE    
  Shundredth -32768..32767  

aModuleName 1.3.6.1.4.1.34097.9.65.1.1.10001
Gets, sets or defaults the module name.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

aFirmwareVersion 1.3.6.1.4.1.34097.9.65.1.1.10002
Gets the version of the module's firmware.
Status: current Access: read-only
OBJECT-TYPE    
  Version  

aHardwareVersion 1.3.6.1.4.1.34097.9.65.1.1.10003
Gets the version of a module's hardware.
Status: current Access: read-only
OBJECT-TYPE    
  Version  

aFirmwareID 1.3.6.1.4.1.34097.9.65.1.1.10004
Gets the ID of the module's firmware.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

aHardwareID 1.3.6.1.4.1.34097.9.65.1.1.10005
Gets the ID of a module's hardware.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

aDisplayTimeOn 1.3.6.1.4.1.34097.9.65.1.1.10032
Gets, sets or defaults the display sleep timer. If the display is inactive for longer than this time, the display turns off to save power. Time is in minutes. (unit: min)
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..255  

aMaxVoltageWarning 1.3.6.1.4.1.34097.9.65.1.1.10047
Gets, sets or defaults the maximum voltage warning level. (unit: 0.01V)
Status: current Access: read-write
OBJECT-TYPE    
  Uhundredth 0..65535  

aMinVoltageWarning 1.3.6.1.4.1.34097.9.65.1.1.10049
Gets, sets or defaults the minimum voltage warning level. (unit: 0.01V)
Status: current Access: read-write
OBJECT-TYPE    
  Uhundredth 0..65535  

aMinTemperatureWarning 1.3.6.1.4.1.34097.9.65.1.1.10052
Gets, sets or defaults the minimum temperature warning level (use DEF accessor to reset). (unit: 0.1K)
Status: current Access: read-write
OBJECT-TYPE    
  Utenth 2232..4732  

aMaxTemperatureWarning 1.3.6.1.4.1.34097.9.65.1.1.10053
Gets, sets or defaults the maximum temperature warning level (use DEF accessor to reset). (unit: 0.1K)
Status: current Access: read-write
OBJECT-TYPE    
  Utenth 2232..4732  

aMinHumidityWarning 1.3.6.1.4.1.34097.9.65.1.1.10054
Gets, sets or defaults the minimum relative humidity warning level (use DEF accessor to reset). (unit: 0.1RH)
Status: current Access: read-write
OBJECT-TYPE    
  Utenth 0..1000  

aMaxHumidityWarning 1.3.6.1.4.1.34097.9.65.1.1.10055
Gets, sets or defaults the maximum relative humidity warning level (use DEF accessor to reset). (unit: 0.1RH)
Status: current Access: read-write
OBJECT-TYPE    
  Utenth 0..1000  

aCurrentWarningEvent 1.3.6.1.4.1.34097.9.65.1.1.10078
Enables or disables the SNMP trap if the outlet current warning level is exceeded.
Status: current Access: read-write
OBJECT-TYPE    
  EVENTFLAGS  

aPowerWarningEvent 1.3.6.1.4.1.34097.9.65.1.1.10080
Enables or disables the SNMP trap if the power warning level is exceeded.
Status: current Access: read-write
OBJECT-TYPE    
  EVENTFLAGS  

aVoltageWarningEvent 1.3.6.1.4.1.34097.9.65.1.1.10086
Enables or disables the SNMP trap if the voltage warning level is exceeded.
Status: current Access: read-write
OBJECT-TYPE    
  EVENTFLAGS  

aTemperatureWarningEvent 1.3.6.1.4.1.34097.9.65.1.1.10087
Enables or disables the SNMP trap if the temperature warning level is exceeded.
Status: current Access: read-write
OBJECT-TYPE    
  EVENTFLAGS  

aHumidityWarningEvent 1.3.6.1.4.1.34097.9.65.1.1.10088
Enables or disables the SNMP trap if the humidity warning level is exceeded.
Status: current Access: read-write
OBJECT-TYPE    
  EVENTFLAGS  

aDewPointWarning 1.3.6.1.4.1.34097.9.65.1.1.10092
Gets, sets or defaults the dewpoint warning level. If the temperature difference between the current temperature and the dewpoint temperature drops below this value, an event is generated. (unit: 0.1K)
Status: current Access: read-write
OBJECT-TYPE    
  Utenth 0..65535  

aDewPointWarningEvent 1.3.6.1.4.1.34097.9.65.1.1.10093
Enables or disables the SNMP trap if the dewpoint warning level is exceeded.
Status: current Access: read-write
OBJECT-TYPE    
  EVENTFLAGS  

aDewPointViolationEvent 1.3.6.1.4.1.34097.9.65.1.1.10094
Enables or disables the SNMP trap if the dewpoint temperature is reached.
Status: current Access: read-write
OBJECT-TYPE    
  EVENTFLAGS  

aPressureWarningEvent 1.3.6.1.4.1.34097.9.65.1.1.10095
Enables or disables the SNMP trap if the atmospheric pressure warning level is exceeded.
Status: current Access: read-write
OBJECT-TYPE    
  EVENTFLAGS  

aMinPressureWarning 1.3.6.1.4.1.34097.9.65.1.1.10096
Gets, sets or defaults the minimum atmospheric pressure warning level. (unit: 0.1hPa)
Status: current Access: read-write
OBJECT-TYPE    
  Utenth 0..65535  

aMaxPressureWarning 1.3.6.1.4.1.34097.9.65.1.1.10097
Gets, sets or defaults the maximum atmospheric pressure warning level. (unit: 0.1hPa)
Status: current Access: read-write
OBJECT-TYPE    
  Utenth 0..65535  

aDisplayBrightness 1.3.6.1.4.1.34097.9.65.1.1.10098
Gets, sets or defaults the display brightness (if supported).
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..255  

aMotionSensitivity 1.3.6.1.4.1.34097.9.65.1.1.10107
Gets, sets or defaults the sensitivity of a motion sensor.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..127  

aExternalSensorLabel 1.3.6.1.4.1.34097.9.65.1.1.10109
Gets, sets or defaults the external sensor label. External sensors can be connected to Energy Sensors.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

aRelayLabel 1.3.6.1.4.1.34097.9.65.1.1.10110
Gets, sets or defaults an Energy Sensor relay label.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

aMinAnalogueInputWarning 1.3.6.1.4.1.34097.9.65.1.1.10111
Gets, sets or defaults the lower warning level for an analog input. A warning is generated if this level is exceeded. (unit: mV)
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..65535  

aMaxAnalogueInputWarning 1.3.6.1.4.1.34097.9.65.1.1.10112
Gets, sets or defaults the upper warning level for an analog input. A warning is generated if this level is exceeded.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..65535  

aWaterleakWarning 1.3.6.1.4.1.34097.9.65.1.1.10113
Gets, sets or defaults the water leak detection state (0 = disabled, other values = enabled).
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..65535  

aMinAirflowWarning 1.3.6.1.4.1.34097.9.65.1.1.10114
Gets, sets or defaults the minimum warning level for an airflow sensor. A warning is generated if this level is exceeded.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..65535  

aMaxAirflowWarning 1.3.6.1.4.1.34097.9.65.1.1.10115
Gets, sets or defaults the maximum warning level for an airflow sensor. A warning is generated if this level is exceeded.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..65535  

aAnalogueInputWarningEvent 1.3.6.1.4.1.34097.9.65.1.1.10116
Enables or disables the SNMP trap if the analog input warning level is exceeded.
Status: current Access: read-write
OBJECT-TYPE    
  EVENTFLAGS  

aWaterleakWarningEvent 1.3.6.1.4.1.34097.9.65.1.1.10117
Enables or disables the SNMP trap if a water leak is detected.
Status: current Access: read-write
OBJECT-TYPE    
  EVENTFLAGS  

aAirflowWarningEvent 1.3.6.1.4.1.34097.9.65.1.1.10118
Enables or disables the SNMP trap if the airflow warning level is exceeded.
Status: current Access: read-write
OBJECT-TYPE    
  EVENTFLAGS  

aRelayAssertActionEvent 1.3.6.1.4.1.34097.9.65.1.1.10119
Enables or disables the SNMP trap if an Energy Sensor relay is asserted.
Status: current Access: read-write
OBJECT-TYPE    
  EVENTFLAGS  

aRelayDeassertActionEvent 1.3.6.1.4.1.34097.9.65.1.1.10120
Enables or disables the SNMP trap if an Energy Sensor relay is deasserted.
Status: current Access: read-write
OBJECT-TYPE    
  EVENTFLAGS  

aMotionWarning 1.3.6.1.4.1.34097.9.65.1.1.10141
Gets, sets or defaults the motion warning threshold.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..127  

aMotionWarningEvent 1.3.6.1.4.1.34097.9.65.1.1.10149
Enables or disables the SNMP trap if the motion warning threshold is exceeded.
Status: current Access: read-write
OBJECT-TYPE    
  EVENTFLAGS  

aDeviceID 1.3.6.1.4.1.34097.9.65.1.1.10150
The ID of the device.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

aDeviceVersion 1.3.6.1.4.1.34097.9.65.1.1.10151
The version of the device.
Status: current Access: read-only
OBJECT-TYPE    
  Version  

aSysName 1.3.6.1.4.1.34097.9.65.1.1.10152
The full name of the device.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

aMaxHighCurrentWarning 1.3.6.1.4.1.34097.9.65.1.1.10165
Gets sets or defaults the maximum high current warning level. (unit: 0.1A)
Status: current Access: read-write
OBJECT-TYPE    
  Stenth -32768..32767  

aMinHighCurrentWarning 1.3.6.1.4.1.34097.9.65.1.1.10176
Gets sets or defaults the minimum high current warning level. (unit: 0.1A)
Status: current Access: read-write
OBJECT-TYPE    
  Stenth -32768..32767  

aMinHighPowerWarning 1.3.6.1.4.1.34097.9.65.1.1.10177
Gets sets or defaults the power min high current warning level. (unit: 0.01kW)
Status: current Access: read-write
OBJECT-TYPE    
  Shundredth -32768..32767  

aMaxHighPowerWarning 1.3.6.1.4.1.34097.9.65.1.1.10178
Gets sets or defaults the power max high current warning level. (unit: 0.01kW)
Status: current Access: read-write
OBJECT-TYPE    
  Shundredth -32768..32767  

aIOPortWarningEvent 1.3.6.1.4.1.34097.9.65.1.1.10192
Enables or disables the SNMP trap if the IO Port change state.
Status: current Access: read-write
OBJECT-TYPE    
  EVENTFLAGS  

testmoduleModule 1.3.6.1.4.1.34097.9.89
OBJECT IDENTIFIER    

eTestModuleTable 1.3.6.1.4.1.34097.9.89.1
Module to test the R-bus
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ETestModuleEntry

eTestModuleEntry 1.3.6.1.4.1.34097.9.89.1.1
Module to test the R-bus
Status: current Access: not-accessible
OBJECT-TYPE    
  ETestModuleEntry  

testmoduleIndex 1.3.6.1.4.1.34097.9.89.1.1.65537
Index for the selected TestModule Module
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..8  

testmoduleModuleIndex 1.3.6.1.4.1.34097.9.89.1.1.65538
Selected TestModule Module
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..8  

yGeneralModuleStatus 1.3.6.1.4.1.34097.9.89.1.1.1
General status of a module.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

ySpecificModuleStatus 1.3.6.1.4.1.34097.9.89.1.1.2
Specific status of a module.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

yCurrentTime 1.3.6.1.4.1.34097.9.89.1.1.3
Gets or sets the current time (not possible when NTP is enabled). (unit: UNIX)
Status: current Access: read-write
OBJECT-TYPE    
  TimeTicks  

yCurrent 1.3.6.1.4.1.34097.9.89.1.1.6
Gets the current of an outlet. (unit: 0.001A)
Status: current Access: read-only
OBJECT-TYPE    
  Uthousandth  

yStatePortCur 1.3.6.1.4.1.34097.9.89.1.1.8
Gets the current state of an outlet. To toggle an outlet use PORTSTAT (CLI) or pPortstate (SNMP) (GUID 10035) instead.
Status: current Access: read-only
OBJECT-TYPE    
  CURPORTSTATE  

yAnalogueInput 1.3.6.1.4.1.34097.9.89.1.1.27
Gets the value of an analog input (voltage). (unit: mV)
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

yModuleName 1.3.6.1.4.1.34097.9.89.1.1.10001
Gets, sets or defaults the module name.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

yFirmwareVersion 1.3.6.1.4.1.34097.9.89.1.1.10002
Gets the version of the module's firmware.
Status: current Access: read-only
OBJECT-TYPE    
  Version  

yHardwareVersion 1.3.6.1.4.1.34097.9.89.1.1.10003
Gets the version of a module's hardware.
Status: current Access: read-only
OBJECT-TYPE    
  Version  

yFirmwareID 1.3.6.1.4.1.34097.9.89.1.1.10004
Gets the ID of the module's firmware.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

yHardwareID 1.3.6.1.4.1.34097.9.89.1.1.10005
Gets the ID of a module's hardware.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

pcModule 1.3.6.1.4.1.34097.9.85
OBJECT IDENTIFIER    

ePCTable 1.3.6.1.4.1.34097.9.85.1
NO_INFO
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    EPCEntry

ePCEntry 1.3.6.1.4.1.34097.9.85.1.1
NO_INFO
Status: current Access: not-accessible
OBJECT-TYPE    
  EPCEntry  

pcIndex 1.3.6.1.4.1.34097.9.85.1.1.65537
Index for the selected PC Module
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..8  

pcModuleIndex 1.3.6.1.4.1.34097.9.85.1.1.65538
Selected PC Module
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..8  

uGeneralModuleStatus 1.3.6.1.4.1.34097.9.85.1.1.1
General status of a module.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

uSpecificModuleStatus 1.3.6.1.4.1.34097.9.85.1.1.2
Specific status of a module.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

uCurrentTime 1.3.6.1.4.1.34097.9.85.1.1.3
Gets or sets the current time (not possible when NTP is enabled). (unit: UNIX)
Status: current Access: read-write
OBJECT-TYPE    
  TimeTicks  

uVoltage 1.3.6.1.4.1.34097.9.85.1.1.4
Gets the voltage of a power module. (unit: 0.01V)
Status: current Access: read-only
OBJECT-TYPE    
  Uhundredth 0..65535  

uCurrent 1.3.6.1.4.1.34097.9.85.1.1.6
Gets the current of an outlet. (unit: 0.001A)
Status: current Access: read-only
OBJECT-TYPE    
  Uthousandth 0..65535  

uStatePortCur 1.3.6.1.4.1.34097.9.85.1.1.8
Gets the current state of an outlet. To toggle an outlet use PORTSTAT (CLI) or pPortstate (SNMP) (GUID 10035) instead.
Status: current Access: read-only
OBJECT-TYPE    
  CURPORTSTATE  

uTemperature 1.3.6.1.4.1.34097.9.85.1.1.11
Gets the current temperature of a temperature sensor. (unit: 0.1K)
Status: current Access: read-only
OBJECT-TYPE    
  Utenth 2232..4732  

uHumidity 1.3.6.1.4.1.34097.9.85.1.1.12
Gets the relative humidity. (unit: 0.1RH)
Status: current Access: read-only
OBJECT-TYPE    
  Utenth 0..1000  

uModuleName 1.3.6.1.4.1.34097.9.85.1.1.10001
Gets, sets or defaults the module name.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

uFirmwareVersion 1.3.6.1.4.1.34097.9.85.1.1.10002
Gets the version of the module's firmware.
Status: current Access: read-only
OBJECT-TYPE    
  Version  

uHardwareVersion 1.3.6.1.4.1.34097.9.85.1.1.10003
Gets the version of a module's hardware.
Status: current Access: read-only
OBJECT-TYPE    
  Version  

uFirmwareID 1.3.6.1.4.1.34097.9.85.1.1.10004
Gets the ID of the module's firmware.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

uHardwareID 1.3.6.1.4.1.34097.9.85.1.1.10005
Gets the ID of a module's hardware.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

uPortState 1.3.6.1.4.1.34097.9.85.1.1.10035
Sets the state of an outlet: 0=OFF, 1=ON, 2=POWER CYCLE. To get the state of an outlet use CPORTSTAT (CLI) or pStatePortCur (SNMP) (GUID 8) instead.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..1  

energymonitorModule 1.3.6.1.4.1.34097.9.69
OBJECT IDENTIFIER    

eEnergyMonitorTable 1.3.6.1.4.1.34097.9.69.1
NO_INFO
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    EEnergyMonitorEntry

eEnergyMonitorEntry 1.3.6.1.4.1.34097.9.69.1.1
NO_INFO
Status: current Access: not-accessible
OBJECT-TYPE    
  EEnergyMonitorEntry  

energymonitorIndex 1.3.6.1.4.1.34097.9.69.1.1.65537
Index for the selected EnergyMonitor Module
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..8  

energymonitorModuleIndex 1.3.6.1.4.1.34097.9.69.1.1.65538
Selected EnergyMonitor Module
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..8  

eGeneralModuleStatus 1.3.6.1.4.1.34097.9.69.1.1.1
General status of a module.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

eSpecificModuleStatus 1.3.6.1.4.1.34097.9.69.1.1.2
Specific status of a module.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

eCurrentTime 1.3.6.1.4.1.34097.9.69.1.1.3
Gets or sets the current time (not possible when NTP is enabled). (unit: UNIX)
Status: current Access: read-write
OBJECT-TYPE    
  TimeTicks  

eVoltage 1.3.6.1.4.1.34097.9.69.1.1.4
Gets the voltage of a power module. (unit: 0.01V)
Status: current Access: read-only
OBJECT-TYPE    
  Uhundredth  

eFrequency 1.3.6.1.4.1.34097.9.69.1.1.5
Gets the frequency of the input voltage of a power module. (unit: 0.001Hz)
Status: current Access: read-only
OBJECT-TYPE    
  Uthousandth  

eCurrent 1.3.6.1.4.1.34097.9.69.1.1.6
Gets the current of an outlet. (unit: 0.001A)
Status: current Access: read-only
OBJECT-TYPE    
  Uthousandth  

ePower 1.3.6.1.4.1.34097.9.69.1.1.7
Gets the power of an outlet. (unit: W)
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

eActiveEnergy 1.3.6.1.4.1.34097.9.69.1.1.9
Gets the energy used by an outlet. (unit: 0.001kWh)
Status: current Access: read-only
OBJECT-TYPE    
  Uthousandth  

eApparentEnergy 1.3.6.1.4.1.34097.9.69.1.1.10
Gets the apparent energy used by an outlet. (unit: 0.001kVAh)
Status: current Access: read-only
OBJECT-TYPE    
  Uthousandth  

eTemperature 1.3.6.1.4.1.34097.9.69.1.1.11
Gets the current temperature of a temperature sensor. (unit: 0.1K)
Status: current Access: read-only
OBJECT-TYPE    
  Utenth  

eApparentPower 1.3.6.1.4.1.34097.9.69.1.1.15
Gets the apparent power of an outlet. (unit: VA)
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

ePowerFactor 1.3.6.1.4.1.34097.9.69.1.1.16
Gets the power factor of an outlet. (unit: %)
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

eTotalCurrent 1.3.6.1.4.1.34097.9.69.1.1.17
Gets the total current of a power module. (unit: 0.001A)
Status: current Access: read-only
OBJECT-TYPE    
  Uthousandth  

eTotalRealPower 1.3.6.1.4.1.34097.9.69.1.1.18
Gets the total power level of a power module. (unit: W)
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

eTotalApparentPower 1.3.6.1.4.1.34097.9.69.1.1.19
Gets the total apparent power of a power module. (unit: VA)
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

eTotalActiveEnergy 1.3.6.1.4.1.34097.9.69.1.1.20
Gets the total energy of a power module. (unit: 0.001kWh)
Status: current Access: read-only
OBJECT-TYPE    
  Uthousandth  

eTotalApparentEnergy 1.3.6.1.4.1.34097.9.69.1.1.21
Gets the total apparent energy of a power module. (unit: 0.001kVAh)
Status: current Access: read-only
OBJECT-TYPE    
  Uthousandth  

eTotalPowerFactor 1.3.6.1.4.1.34097.9.69.1.1.22
Gets the total power factor of a power module. (unit: %)
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

eTimeOnline 1.3.6.1.4.1.34097.9.69.1.1.24
Gets the amount of seconds since the last reset. (unit: s)
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

eTotalHarmonicDistortion 1.3.6.1.4.1.34097.9.69.1.1.50
total harmonic distortion - outlet (unit: 0.1%)
Status: current Access: read-only
OBJECT-TYPE    
  Utenth 0..1000  

eModuleName 1.3.6.1.4.1.34097.9.69.1.1.10001
Gets, sets or defaults the module name.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

eFirmwareVersion 1.3.6.1.4.1.34097.9.69.1.1.10002
Gets the version of the module's firmware.
Status: current Access: read-only
OBJECT-TYPE    
  Version  

eHardwareVersion 1.3.6.1.4.1.34097.9.69.1.1.10003
Gets the version of a module's hardware.
Status: current Access: read-only
OBJECT-TYPE    
  Version  

eFirmwareID 1.3.6.1.4.1.34097.9.69.1.1.10004
Gets the ID of the module's firmware.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

eHardwareID 1.3.6.1.4.1.34097.9.69.1.1.10005
Gets the ID of a module's hardware.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

eMaxCurrentWarning 1.3.6.1.4.1.34097.9.69.1.1.10039
Gets, sets or defaults the maximum current warning level of an outlet. (unit: 0.001A)
Status: current Access: read-write
OBJECT-TYPE    
  Uthousandth 100..8000  

eMaxPowerWarning 1.3.6.1.4.1.34097.9.69.1.1.10041
Gets, sets or defaults the maximum power warning level of an outlet. (unit: W)
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 20..2000  

eMaxTotalCurrentWarning 1.3.6.1.4.1.34097.9.69.1.1.10043
Gets, sets or defaults the total maximum current warning level of a power module. (unit: 0.001A)
Status: current Access: read-write
OBJECT-TYPE    
  Uthousandth 100..16000  

eMaxTotalPowerWarning 1.3.6.1.4.1.34097.9.69.1.1.10045
Gets, sets or defaults the maximum total power warning level. (unit: W)
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 20..4000  

eMaxVoltageWarning 1.3.6.1.4.1.34097.9.69.1.1.10047
Gets, sets or defaults the maximum voltage warning level. (unit: 0.01V)
Status: current Access: read-write
OBJECT-TYPE    
  Uhundredth 5000..30000  

eMinVoltageWarning 1.3.6.1.4.1.34097.9.69.1.1.10049
Gets, sets or defaults the minimum voltage warning level. (unit: 0.01V)
Status: current Access: read-write
OBJECT-TYPE    
  Uhundredth 5000..30000  

eMinTemperatureWarning 1.3.6.1.4.1.34097.9.69.1.1.10052
Gets, sets or defaults the minimum temperature warning level (use DEF accessor to reset). (unit: 0.1K)
Status: current Access: read-write
OBJECT-TYPE    
  Utenth 2232..4732  

eMaxTemperatureWarning 1.3.6.1.4.1.34097.9.69.1.1.10053
Gets, sets or defaults the maximum temperature warning level (use DEF accessor to reset). (unit: 0.1K)
Status: current Access: read-write
OBJECT-TYPE    
  Utenth 2232..4732  

eCurrentWarningEvent 1.3.6.1.4.1.34097.9.69.1.1.10078
Enables or disables the SNMP trap if the outlet current warning level is exceeded.
Status: current Access: read-write
OBJECT-TYPE    
  EVENTFLAGS  

ePowerWarningEvent 1.3.6.1.4.1.34097.9.69.1.1.10080
Enables or disables the SNMP trap if the power warning level is exceeded.
Status: current Access: read-write
OBJECT-TYPE    
  EVENTFLAGS  

eTotalCurrentWarningEvent 1.3.6.1.4.1.34097.9.69.1.1.10082
Enables or disables the SNMP trap if the total outlet current warning level is exceeded.
Status: current Access: read-write
OBJECT-TYPE    
  EVENTFLAGS  

eTotalPowerWarningEvent 1.3.6.1.4.1.34097.9.69.1.1.10084
Enables or disables the SNMP trap if the total power warning level is exceeded.
Status: current Access: read-write
OBJECT-TYPE    
  EVENTFLAGS  

eVoltageWarningEvent 1.3.6.1.4.1.34097.9.69.1.1.10086
Enables or disables the SNMP trap if the voltage warning level is exceeded.
Status: current Access: read-write
OBJECT-TYPE    
  EVENTFLAGS  

eTemperatureWarningEvent 1.3.6.1.4.1.34097.9.69.1.1.10087
Enables or disables the SNMP trap if the temperature warning level is exceeded.
Status: current Access: read-write
OBJECT-TYPE    
  EVENTFLAGS  

eMicroIntTimeThreshold 1.3.6.1.4.1.34097.9.69.1.1.10135
The minimum time the voltage must be interrupted before it is seen as a micro interruption (unit: 0.1ms)
Status: current Access: read-write
OBJECT-TYPE    
  Utenth 10..65535  

eMicroIntEvent 1.3.6.1.4.1.34097.9.69.1.1.10136
Enables or disables the SNMP trap if a microinterruption on the voltage is detected.
Status: current Access: read-write
OBJECT-TYPE    
  EVENTFLAGS  

threephasepowerModule 1.3.6.1.4.1.34097.9.66
OBJECT IDENTIFIER    

eThreePhasePowerTable 1.3.6.1.4.1.34097.9.66.1
NO_INFO
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    EThreePhasePowerEntry

eThreePhasePowerEntry 1.3.6.1.4.1.34097.9.66.1.1
NO_INFO
Status: current Access: not-accessible
OBJECT-TYPE    
  EThreePhasePowerEntry  

threephasepowerIndex 1.3.6.1.4.1.34097.9.66.1.1.65537
Index for the selected ThreePhasePower Module
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..8  

threephasepowerModuleIndex 1.3.6.1.4.1.34097.9.66.1.1.65538
Selected ThreePhasePower Module
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..8  

measuring3phaseModule 1.3.6.1.4.1.34097.9.81
OBJECT IDENTIFIER    

eMeasuring3PhaseTable 1.3.6.1.4.1.34097.9.81.1
NO_INFO
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    EMeasuring3PhaseEntry

eMeasuring3PhaseEntry 1.3.6.1.4.1.34097.9.81.1.1
NO_INFO
Status: current Access: not-accessible
OBJECT-TYPE    
  EMeasuring3PhaseEntry  

measuring3phaseIndex 1.3.6.1.4.1.34097.9.81.1.1.65537
Index for the selected Measuring3Phase Module
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..8  

measuring3phaseModuleIndex 1.3.6.1.4.1.34097.9.81.1.1.65538
Selected Measuring3Phase Module
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..8  

qGeneralModuleStatus 1.3.6.1.4.1.34097.9.81.1.1.1
General status of a module.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

qSpecificModuleStatus 1.3.6.1.4.1.34097.9.81.1.1.2
Specific status of a module.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

qCurrentTime 1.3.6.1.4.1.34097.9.81.1.1.3
Gets or sets the current time (not possible when NTP is enabled). (unit: UNIX)
Status: current Access: read-write
OBJECT-TYPE    
  TimeTicks  

qVoltage 1.3.6.1.4.1.34097.9.81.1.1.4
Gets the voltage of a power module. (unit: 0.01V)
Status: current Access: read-only
OBJECT-TYPE    
  Uhundredth  

qFrequency 1.3.6.1.4.1.34097.9.81.1.1.5
Gets the frequency of the input voltage of a power module. (unit: 0.001Hz)
Status: current Access: read-only
OBJECT-TYPE    
  Uthousandth  

qActiveEnergy 1.3.6.1.4.1.34097.9.81.1.1.9
Gets the energy used by an outlet. (unit: 0.001kWh)
Status: current Access: read-only
OBJECT-TYPE    
  Uthousandth  

qApparentEnergy 1.3.6.1.4.1.34097.9.81.1.1.10
Gets the apparent energy used by an outlet. (unit: 0.001kVAh)
Status: current Access: read-only
OBJECT-TYPE    
  Uthousandth  

qTemperature 1.3.6.1.4.1.34097.9.81.1.1.11
Gets the current temperature of a temperature sensor. (unit: 0.1K)
Status: current Access: read-only
OBJECT-TYPE    
  Utenth  

qPowerFactor 1.3.6.1.4.1.34097.9.81.1.1.16
Gets the power factor of an outlet. (unit: %)
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

qTimeOnline 1.3.6.1.4.1.34097.9.81.1.1.24
Gets the amount of seconds since the last reset. (unit: s)
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

qIOPort 1.3.6.1.4.1.34097.9.81.1.1.30
Gets the state of a digital input.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..1  

qTotalHarmonicDistortion 1.3.6.1.4.1.34097.9.81.1.1.50
total harmonic distortion - outlet (unit: 0.1%)
Status: current Access: read-only
OBJECT-TYPE    
  Utenth 0..1000  

qPhase 1.3.6.1.4.1.34097.9.81.1.1.51
the phase between 2 waves (unit: degr)
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..65535  

qBigCurrent 1.3.6.1.4.1.34097.9.81.1.1.52
Gets the current of an outlet. (unit: 0.0001A)
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

qBigPower 1.3.6.1.4.1.34097.9.81.1.1.53
Gets the power of an outlet. (unit: 0.001W)
Status: current Access: read-only
OBJECT-TYPE    
  Uthousandth  

qBigApparentPower 1.3.6.1.4.1.34097.9.81.1.1.54
Gets the apparent power of an outlet. (unit: 0.001VA)
Status: current Access: read-only
OBJECT-TYPE    
  Uthousandth  

qStatus 1.3.6.1.4.1.34097.9.81.1.1.1000
status of a module
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..65535  

qModuleName 1.3.6.1.4.1.34097.9.81.1.1.10001
Gets, sets or defaults the module name.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

qFirmwareVersion 1.3.6.1.4.1.34097.9.81.1.1.10002
Gets the version of the module's firmware.
Status: current Access: read-only
OBJECT-TYPE    
  Version  

qHardwareVersion 1.3.6.1.4.1.34097.9.81.1.1.10003
Gets the version of a module's hardware.
Status: current Access: read-only
OBJECT-TYPE    
  Version  

qFirmwareID 1.3.6.1.4.1.34097.9.81.1.1.10004
Gets the ID of the module's firmware.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

qHardwareID 1.3.6.1.4.1.34097.9.81.1.1.10005
Gets the ID of a module's hardware.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

qPortState 1.3.6.1.4.1.34097.9.81.1.1.10035
Sets the state of an outlet: 0=OFF, 1=ON, 2=POWER CYCLE. To get the state of an outlet use CPORTSTAT (CLI) or pStatePortCur (SNMP) (GUID 8) instead.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..1  

qMaxVoltageWarning 1.3.6.1.4.1.34097.9.81.1.1.10047
Gets, sets or defaults the maximum voltage warning level. (unit: 0.01V)
Status: current Access: read-write
OBJECT-TYPE    
  Uhundredth 5000..30000  

qMinVoltageWarning 1.3.6.1.4.1.34097.9.81.1.1.10049
Gets, sets or defaults the minimum voltage warning level. (unit: 0.01V)
Status: current Access: read-write
OBJECT-TYPE    
  Uhundredth 5000..30000  

qMinTemperatureWarning 1.3.6.1.4.1.34097.9.81.1.1.10052
Gets, sets or defaults the minimum temperature warning level (use DEF accessor to reset). (unit: 0.1K)
Status: current Access: read-write
OBJECT-TYPE    
  Utenth 2232..4732  

qMaxTemperatureWarning 1.3.6.1.4.1.34097.9.81.1.1.10053
Gets, sets or defaults the maximum temperature warning level (use DEF accessor to reset). (unit: 0.1K)
Status: current Access: read-write
OBJECT-TYPE    
  Utenth 2232..4732  

qPortStateEvent 1.3.6.1.4.1.34097.9.81.1.1.10076
Enables or disables the SNMP trap if the state of an outlet is changed.
Status: current Access: read-write
OBJECT-TYPE    
  EVENTFLAGS  

qCurrentWarningEvent 1.3.6.1.4.1.34097.9.81.1.1.10078
Enables or disables the SNMP trap if the outlet current warning level is exceeded.
Status: current Access: read-write
OBJECT-TYPE    
  EVENTFLAGS  

qPowerWarningEvent 1.3.6.1.4.1.34097.9.81.1.1.10080
Enables or disables the SNMP trap if the power warning level is exceeded.
Status: current Access: read-write
OBJECT-TYPE    
  EVENTFLAGS  

qVoltageWarningEvent 1.3.6.1.4.1.34097.9.81.1.1.10086
Enables or disables the SNMP trap if the voltage warning level is exceeded.
Status: current Access: read-write
OBJECT-TYPE    
  EVENTFLAGS  

qTemperatureWarningEvent 1.3.6.1.4.1.34097.9.81.1.1.10087
Enables or disables the SNMP trap if the temperature warning level is exceeded.
Status: current Access: read-write
OBJECT-TYPE    
  EVENTFLAGS  

qMicroIntTimeThreshold 1.3.6.1.4.1.34097.9.81.1.1.10135
The minimum time the voltage must be interrupted before it is seen as a micro interruption (unit: 0.1ms)
Status: current Access: read-write
OBJECT-TYPE    
  Utenth 10..65535  

qMicroIntEvent 1.3.6.1.4.1.34097.9.81.1.1.10136
Enables or disables the SNMP trap if a microinterruption on the voltage is detected.
Status: current Access: read-write
OBJECT-TYPE    
  EVENTFLAGS  

qDeviceID 1.3.6.1.4.1.34097.9.81.1.1.10150
The ID of the device.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

qDeviceVersion 1.3.6.1.4.1.34097.9.81.1.1.10151
The version of the device.
Status: current Access: read-only
OBJECT-TYPE    
  Version  

qMaxBigCurrentWarning 1.3.6.1.4.1.34097.9.81.1.1.10193
Gets, sets or defaults the maximum current warning level of an outlet. (unit: 0.0001A)
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 100..400000000  

qMaxBigPowerWarning 1.3.6.1.4.1.34097.9.81.1.1.10194
Gets, sets or defaults the maximum power warning level of an outlet. (unit: 0.001W)
Status: current Access: read-write
OBJECT-TYPE    
  Uthousandth 2000..2000000000  

qCurrentSensorSelector 1.3.6.1.4.1.34097.9.81.1.1.10197
Selection of the currentsensor connected to port. To enter your own value you need to use 255 and fill in guid 10190.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..255  

qMinBigCurrentWarning 1.3.6.1.4.1.34097.9.81.1.1.10209
Gets, sets or defaults the minimum current warning level of a port. (unit: 0.0001A)
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..400000000  

qkWhMode 1.3.6.1.4.1.34097.9.81.1.1.10234
Set the mode when to count kWh, 0 = always, 1 = only positive, 2= only negative
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..2  

displaymoduleModule 1.3.6.1.4.1.34097.9.68
OBJECT IDENTIFIER    

eDisplayModuleTable 1.3.6.1.4.1.34097.9.68.1
NO_INFO
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    EDisplayModuleEntry

eDisplayModuleEntry 1.3.6.1.4.1.34097.9.68.1.1
NO_INFO
Status: current Access: not-accessible
OBJECT-TYPE    
  EDisplayModuleEntry  

displaymoduleIndex 1.3.6.1.4.1.34097.9.68.1.1.65537
Index for the selected DisplayModule Module
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..8  

displaymoduleModuleIndex 1.3.6.1.4.1.34097.9.68.1.1.65538
Selected DisplayModule Module
Status: current Access: not-accessible
OBJECT-TYPE    
  Integer32 1..8  

dGeneralModuleStatus 1.3.6.1.4.1.34097.9.68.1.1.1
General status of a module.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

dSpecificModuleStatus 1.3.6.1.4.1.34097.9.68.1.1.2
Specific status of a module.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

dCurrentTime 1.3.6.1.4.1.34097.9.68.1.1.3
Gets or sets the current time (not possible when NTP is enabled). (unit: UNIX)
Status: current Access: read-write
OBJECT-TYPE    
  TimeTicks  

dTemperature 1.3.6.1.4.1.34097.9.68.1.1.11
Gets the current temperature of a temperature sensor. (unit: 0.1K)
Status: current Access: read-only
OBJECT-TYPE    
  Utenth  

dTimeOnline 1.3.6.1.4.1.34097.9.68.1.1.24
Gets the amount of seconds since the last reset. (unit: s)
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

dModuleName 1.3.6.1.4.1.34097.9.68.1.1.10001
Gets, sets or defaults the module name.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString  

dFirmwareVersion 1.3.6.1.4.1.34097.9.68.1.1.10002
Gets the version of the module's firmware.
Status: current Access: read-only
OBJECT-TYPE    
  Version  

dHardwareVersion 1.3.6.1.4.1.34097.9.68.1.1.10003
Gets the version of a module's hardware.
Status: current Access: read-only
OBJECT-TYPE    
  Version  

dFirmwareID 1.3.6.1.4.1.34097.9.68.1.1.10004
Gets the ID of the module's firmware.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

dHardwareID 1.3.6.1.4.1.34097.9.68.1.1.10005
Gets the ID of a module's hardware.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

dMinTemperatureWarning 1.3.6.1.4.1.34097.9.68.1.1.10052
Gets, sets or defaults the minimum temperature warning level (use DEF accessor to reset). (unit: 0.1K)
Status: current Access: read-write
OBJECT-TYPE    
  Utenth 2232..4732  

dMaxTemperatureWarning 1.3.6.1.4.1.34097.9.68.1.1.10053
Gets, sets or defaults the maximum temperature warning level (use DEF accessor to reset). (unit: 0.1K)
Status: current Access: read-write
OBJECT-TYPE    
  Utenth 2232..4732  

dDisplayAllDevices 1.3.6.1.4.1.34097.9.68.1.1.10237
If a display need to show all devices or just a small list
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..1  

errorValueTooHighRaised 1.3.6.1.4.1.34097.9.0.16
This trap is sent when an element goes above the specified error threshold indicating the maximum value for this element
Status: current Access: read-write
NOTIFICATION-TYPE    

errorValueTooLowRaised 1.3.6.1.4.1.34097.9.0.17
This trap is sent when an element goes below the specified error threshold indicating the minimum value for this element
Status: current Access: read-write
NOTIFICATION-TYPE    

errorRaised 1.3.6.1.4.1.34097.9.0.18
This trap is sent when an element gets into an error state
Status: current Access: read-write
NOTIFICATION-TYPE    

errorValueTooHighCleared 1.3.6.1.4.1.34097.9.0.19
This trap is sent when an element goes below the specified error threshold indicating the maximum value for this element
Status: current Access: read-write
NOTIFICATION-TYPE    

errorValueTooLowCleared 1.3.6.1.4.1.34097.9.0.20
This trap is sent when an element goes above the specified error threshold indicating the minimum value for this element
Status: current Access: read-write
NOTIFICATION-TYPE    

errorCleared 1.3.6.1.4.1.34097.9.0.21
This trap is sent when an element recovers from an error state
Status: current Access: read-write
NOTIFICATION-TYPE    

warningValueTooHighRaised 1.3.6.1.4.1.34097.9.0.48
This trap is sent when an element goes above the specified warning threshold indicating the maximum value for this element
Status: current Access: read-write
NOTIFICATION-TYPE    

warningValueTooLowRaised 1.3.6.1.4.1.34097.9.0.49
This trap is sent when an element goes below the specified warning threshold indicating the minimum value for this element
Status: current Access: read-write
NOTIFICATION-TYPE    

warningRaised 1.3.6.1.4.1.34097.9.0.50
This trap is sent when an element gets into an warning state
Status: current Access: read-write
NOTIFICATION-TYPE    

warningValueTooHighCleared 1.3.6.1.4.1.34097.9.0.51
This trap is sent when an element goes below the specified warning threshold indicating the maximum value for this element
Status: current Access: read-write
NOTIFICATION-TYPE    

warningValueTooLowCleared 1.3.6.1.4.1.34097.9.0.52
This trap is sent when an element goes above the specified warning threshold indicating the minimum value for this element
Status: current Access: read-write
NOTIFICATION-TYPE    

warningCleared 1.3.6.1.4.1.34097.9.0.53
This trap is sent when an element recovers from an warning state
Status: current Access: read-write
NOTIFICATION-TYPE    

infoValueTooHighRaised 1.3.6.1.4.1.34097.9.0.80
This trap is sent when an element goes above a specified threshold indicating the maximum value for this element
Status: current Access: read-write
NOTIFICATION-TYPE    

infoPortStateChanged 1.3.6.1.4.1.34097.9.0.96
This trap is sent when a port changes state for any reason
Status: current Access: read-write
NOTIFICATION-TYPE    

infoReset 1.3.6.1.4.1.34097.9.0.97
This trap is sent when a module is reboot
Status: current Access: read-write
NOTIFICATION-TYPE    

infoValueTooLowRaised 1.3.6.1.4.1.34097.9.0.81
This trap is sent when an element goes below a specified threshold indicating the minimum value for this element
Status: current Access: read-write
NOTIFICATION-TYPE    

infoRaised 1.3.6.1.4.1.34097.9.0.82
This trap is sent when an element gets into a specific state
Status: current Access: read-write
NOTIFICATION-TYPE    

infoValueTooHighCleared 1.3.6.1.4.1.34097.9.0.83
This trap is sent when an element goes below a specified threshold indicating the maximum value for this element
Status: current Access: read-write
NOTIFICATION-TYPE    

infoValueTooLowCleared 1.3.6.1.4.1.34097.9.0.84
This trap is sent when an element goes above a specified threshold indicating the minimum value for this element
Status: current Access: read-write
NOTIFICATION-TYPE    

infoCleared 1.3.6.1.4.1.34097.9.0.85
This trap is sent when an element recovers from a specific state
Status: current Access: read-write
NOTIFICATION-TYPE    

infoUpgrade 1.3.6.1.4.1.34097.9.0.98
This trap is sent when upgrade or downgrade of firmware is completed
Status: current Access: read-write
NOTIFICATION-TYPE    

warningMicroInterruption 1.3.6.1.4.1.34097.9.0.54
This event is raised when a micro interruption is detected above a threshold time
Status: current Access: read-write
NOTIFICATION-TYPE    

warningPhaseShift 1.3.6.1.4.1.34097.9.0.55
This event is raised when a phase shift is detected above a threshold
Status: current Access: read-write
NOTIFICATION-TYPE    

infoPortSchedule 1.3.6.1.4.1.34097.9.0.99
This trap is sent when a port changes state because of a scheduling
Status: current Access: read-write
NOTIFICATION-TYPE    

infoHeartbeat 1.3.6.1.4.1.34097.9.0.100
This trap is sent when a heartbeat has occurred
Status: current Access: read-write
NOTIFICATION-TYPE    

esRacktivityConformance 1.3.6.1.4.1.34097.9.2
OBJECT IDENTIFIER    

esRacktivityMIBGroups 1.3.6.1.4.1.34097.9.2.1
OBJECT IDENTIFIER    

esRacktivityMIBCompliances 1.3.6.1.4.1.34097.9.2.2
OBJECT IDENTIFIER    

esRacktivityConpliance 1.3.6.1.4.1.34097.9.2.2.1
The compliance statements for a Racktivity device.
Status: current Access: read-write
MODULE-COMPLIANCE    

esRacktivityMIBGroup 1.3.6.1.4.1.34097.9.2.1.1
All accessible objects in a Racktivity device
Status: current Access: read-write
OBJECT-GROUP    

esRacktivityNotificationGroup 1.3.6.1.4.1.34097.9.2.1.2
All notification that can be sent out by a Racktivity device
Status: current Access: read-write