ERI-DNX-STM1-OC3-MIB

File: ERI-DNX-STM1-OC3-MIB.mib (50799 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC ERI-ROOT-SMI
ERI-DNX-SMC-MIB

Imported symbols

MODULE-IDENTITY OBJECT-IDENTITY OBJECT-TYPE
Integer32 Counter32 NOTIFICATION-TYPE
DisplayString TEXTUAL-CONVENTION eriMibs
devices PortStatus OneByteField
NestSlotAddress LinkPortAddress LinkCmdStatus
trapSequence

Defined Types

PayLoadGroupType  
Indicates the type of framing to use within a Synchronous Payload Envelope (SPE) Group. Using the E1, link numbers divisible by 4 are skipped over and not used. (1) t1 - configures all 28 links within the same Payload for VC-11 framing (0) e1 - configures all 21 links within the same Payload for VC-12 framing
TEXTUAL-CONVENTION    
  INTEGER e1(0), t1(1)  

OpticalDevConfigEntry  
SEQUENCE    
  optDevCfgAddr NestSlotAddress
  optDevCfgResource Integer32
  optDevType INTEGER
  optDevMultiplexMode INTEGER
  optLineTiming INTEGER
  optDevPayload1 PayLoadGroupType
  optDevPayload2 PayLoadGroupType
  optDevPayload3 PayLoadGroupType
  optDevCmdStatus INTEGER
  optDevTsAlloc INTEGER
  optDevAssignedToNest Integer32

OptT1E1LinkConfigEntry  
SEQUENCE    
  optT1E1CfgLinkAddr LinkPortAddress
  optT1E1CfgResource Integer32
  optT1E1CfgLinkName DisplayString
  optT1E1Status PortStatus
  optT1E1Clear INTEGER
  optT1E1Framing INTEGER
  optT1E1RecoverTime INTEGER
  optT1E1EsfFormat INTEGER
  optT1E1UnusedTSs INTEGER
  optT1E1CfgCmdStatus LinkCmdStatus
  optT1E1NationalBits OneByteField
  optT1E1InterNational OneByteField

OpticalTUStatusEntry  
SEQUENCE    
  optTUStatusAddr LinkPortAddress
  optTUStatusResrcId Integer32
  optTUStatusLinkState INTEGER
  optTUStatusErrSecs Counter32
  optTUStatusAisErrs Counter32
  optTUStatusLopErrs Counter32
  optTUStatusRdiTUErrs Counter32
  optTUStatusRfiTUErrs Counter32
  optTUStatusPSLMErrs Counter32
  optTUStatusPSLUErrs Counter32
  optTUStatusErrFreeSecs Counter32

OpticalMapperStatusEntry  
SEQUENCE    
  optMapperStatusAddr LinkPortAddress
  optMapperStatusResrcId Integer32
  optMapperState INTEGER
  optMapperErrSecs Counter32
  optMapperErrFreeSecs Counter32
  optMapperLoop INTEGER
  optMapperPathLOPErrs Counter32
  optMapperPathAISErrs Counter32
  optMapperPathRDIErrs Counter32
  optMapperCmdStatus INTEGER

OpticalTransportStatusEntry  
SEQUENCE    
  optTransportStatusAddr NestSlotAddress
  optTransportStatusResrcId Integer32
  optTransportLaserState INTEGER
  optTransportErrSecs Counter32
  optTransportErrFreeSecs Counter32
  optTransportLoop INTEGER
  optTransportLineAISErrs Counter32
  optTransportLineRDIErrs Counter32
  optTransportLineOOFErrs Counter32
  optTransportLineLOFErrs Counter32
  optTransportLineLOSErrs Counter32
  optTransportCmdStatus INTEGER

Defined Values

eriDNXStm1Oc3MIB 1.3.6.1.4.1.644.3.9
The ERI Enterprise MIB Module for the DNX STM1 and OC3 devices.
MODULE-IDENTITY    

dnxStm1Oc3 1.3.6.1.4.1.644.2.4.2.7
OBJECT IDENTIFIER    

opticalConfig 1.3.6.1.4.1.644.2.4.2.7.1
OBJECT IDENTIFIER    

opticalDiag 1.3.6.1.4.1.644.2.4.2.7.2
OBJECT IDENTIFIER    

opticalDevConfigTable 1.3.6.1.4.1.644.2.4.2.7.1.1
This is the STM1/OC3 Device Configuration table which consists of an entry for each of the STM1/OC3 cards. The total number of entries depends on the number of STM1/OC3 cards in the Node.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OpticalDevConfigEntry

opticalDevConfigEntry 1.3.6.1.4.1.644.2.4.2.7.1.1.1
The conceptual row of the STM1/OC3 Device Configuration table. A row in this table cannot be added or deleted, only modified.
Status: current Access: not-accessible
OBJECT-TYPE    
  OpticalDevConfigEntry  

optDevCfgAddr 1.3.6.1.4.1.644.2.4.2.7.1.1.1.1
This number uniquely identifies a STM1/OC3 Device resource. This number will be used throughout the system to identify a unique resource.
Status: current Access: read-only
OBJECT-TYPE    
  NestSlotAddress  

optDevCfgResource 1.3.6.1.4.1.644.2.4.2.7.1.1.1.2
Uniquely identifies an STM1/OC3 Device in the system. This number is provided as key to allow the manager to map this entry to a corresponding Resource Table entry.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optDevType 1.3.6.1.4.1.644.2.4.2.7.1.1.1.3
Identifies the Device as an STM1, OC3, STM1X, or OC3X module.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER stm1(0), oc3(1), stm1X(2), oc3X(3)  

optDevMultiplexMode 1.3.6.1.4.1.644.2.4.2.7.1.1.1.4
Determines the Stm1Oc3 Multiplexing Map Structure to be used: For STM1 SDH Device choose au3, au4, or au4-g707: ------------------------------------------------- (0) au3 - Maps the AUG (Administrative Unit Group) to an AU-3: C-12<-->VC-12<-->TU-12<-->TUG-2<-->VC-3<-->AU-3<-->AUG<-->STM-1 (1) au4 - Maps the AUG (Administrative Unit Group) to an AU-4: C-12<-->VC-12<-->TU-12<-->TUG-2<-->TUG-3<-->VC-4<-->AU-4<-->AUG<-->STM-1 (4) au4-vc3-Seq - Same format as AU-4 but uses sequential link numbering scheme For OC3 SONET Device sts-3 or sts-3c: ------------------------------------- (2) sts-3 - Maps the STS-3 (Synchronous Transport Signal 3) to an SPE: VT-1.5<-->VT-G<-->SPE<-->STS-3<-->OC-3 (3) sts-3c - Maps the STS-3 (Synchronous Transport Signal 3) to an SPE 3c: SPE3c<-->STS-3<-->OC-3
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER au3(0), au4(1), sts-3(2), sts-3c(3), au4-vc3-Seq(4)  

optLineTiming 1.3.6.1.4.1.644.2.4.2.7.1.1.1.5
Identifies the type of Clock Transmit Timing to use for the STM-1 or OC-3 module.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER local(0), loop(1)  

optDevPayload1 1.3.6.1.4.1.644.2.4.2.7.1.1.1.6
Indicates the group framing type to be used for links 1 through 28. Using E1, links 22 through 28 are not used.
Status: current Access: read-write
OBJECT-TYPE    
  PayLoadGroupType  

optDevPayload2 1.3.6.1.4.1.644.2.4.2.7.1.1.1.7
Indicates the tgroup framing type to be used for links 29 through 56. Using E1, links 50 through 56 are not used.
Status: current Access: read-write
OBJECT-TYPE    
  PayLoadGroupType  

optDevPayload3 1.3.6.1.4.1.644.2.4.2.7.1.1.1.8
Indicates the group framing type to be used for links 57 through 84. Using E1, links 78 through 84 are not used.
Status: current Access: read-write
OBJECT-TYPE    
  PayLoadGroupType  

optDevCmdStatus 1.3.6.1.4.1.644.2.4.2.7.1.1.1.9
The command status for this link configuration row/record. The value used in a SET will be replaced by a response value in the GET RESPONSE indicating success or failure. Default Response State used in GET RESPONSE Command ready-for-command (0) initial default status for a row Stm1Oc3 Device Cfg Commands used in SET Command (1..99) update-config(1), Change existing Stm1Oc3 Device Configuration Response States used in GET RESPONSE Command (100..199) update-successful (101) Device data has been successfully changed Stm1Oc3 Device Config Error Codes used in GET RESPONSE Command (400..799) err-general-opt-config-error (400) Unknown Device configuration error occurred err-au4Seq-cannot-be-mixed-framing (402) Au4 sequential mode supports only all-E1 or all-T1 Payloads err-invalid-opt-dev-command (403) Unrecognized device command-action err-device-is-protection-module (414) Can't configure Device designated as Protection (odd # slot) err-invalid-multiplex-map (415) Configured multiplexing structure not valid for device type err-invalid-payload-framing (416) Unrecognized payload group type err-invalid-xlink-nest-num (419) X-Link cannot be assigned to selected Nest err-invalid-line-timing (421) Unrecognized clock setting err-ts-alloc-not-applicable (424) Timeslot Alloc can only be configured for STM1 or OC3 cards in Standalone DNX systems err-xlink-pair-not-applicable (427) X-Link assignement can only be changed for STM1X or OC3X cards in DNX88 systems. err-data-locked-by-another-user (450) Another administrative user is making changes to this part of the system via a terminal session. Check Event Log for user name. err-snmp-parse-failed (500) Agent could not parse variable err-invalid-snmp-type (501) Variable ASN type does not match Agent defined type err-invalid-snmp-var-size (502) Variable size is too big
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER ready-for-command(0), update-config(1), update-successful(101), err-general-opt-config-error(400), err-au4Seq-cannot-be-mixed-framing(402), err-invalid-opt-dev-command(403), err-device-is-protection-module(414), err-invalid-multiplex-map(415), err-invalid-payload-framing(416), err-invalid-xlink-nest-num(419), err-invalid-line-timing(421), err-ts-alloc-not-applicable(424), err-xlink-pair-not-applicable(427), err-data-locked-by-another-user(450), err-snmp-parse-failed(500), err-invalid-snmp-type(501), err-invalid-snmp-var-size(502)  

optDevTsAlloc 1.3.6.1.4.1.644.2.4.2.7.1.1.1.10
Identifies the Timeslot allocation method to use for the STM-1 or OC-3 module. Only applies for stand-alone DNX-11 or DNX-4 systems. DNX-88 systems always use NORMAL.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER normal(0), alternate(1)  

optDevAssignedToNest 1.3.6.1.4.1.644.2.4.2.7.1.1.1.11
Identifies the virtual Nest to use for the STM1-X or OC3-X modules. Only applicable in DNX-88 systems and can only be SET for cards configured in even numbered DNX slots.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 0 | 2..8  

optT1E1LinkConfigTable 1.3.6.1.4.1.644.2.4.2.7.1.2
This is the Stm1Oc3 T1/E1 Link Configuration table which consists of an entry for each of the card's 84 links. The total number of entries depends on the number of STM1 and/or OC3 cards in the Node.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OptT1E1LinkConfigEntry

optT1E1LinkConfigEntry 1.3.6.1.4.1.644.2.4.2.7.1.2.1
The conceptual row of the Stm1Oc3 T1/E1 Link Configuration table. A row in this table cannot be added or deleted, only modified.
Status: current Access: not-accessible
OBJECT-TYPE    
  OptT1E1LinkConfigEntry  

optT1E1CfgLinkAddr 1.3.6.1.4.1.644.2.4.2.7.1.2.1.1
This number uniquely identifies a Stm1Oc3 T1/E1 Link resource. This number will be used throughout the system to identify a unique resource.
Status: current Access: read-only
OBJECT-TYPE    
  LinkPortAddress  

optT1E1CfgResource 1.3.6.1.4.1.644.2.4.2.7.1.2.1.2
Uniquely identifies an Stm1Oc3 T1/E1 Link in the system. This number is provided as key to allow the manager to map this entry to a corresponding Resource Table entry.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optT1E1CfgLinkName 1.3.6.1.4.1.644.2.4.2.7.1.2.1.3
This is the user friendly text name to identify the link.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..20)  

optT1E1Status 1.3.6.1.4.1.644.2.4.2.7.1.2.1.4
Dictates the current status of the link, in-service or out-of-service.
Status: current Access: read-write
OBJECT-TYPE    
  PortStatus  

optT1E1Clear 1.3.6.1.4.1.644.2.4.2.7.1.2.1.5
Determines if the port supports T1 or E1 unframed clear mode or framed clear mode.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), framed(1), unframed(2)  

optT1E1Framing 1.3.6.1.4.1.644.2.4.2.7.1.2.1.6
Determines the type of framing used on the line. Choose between T1 SuperFrame 'D4', Extended SuperFrame (ESF), or T1 Unframed. When value of optT1E1Clear is set to unframed (2), the only valid framing options are: e1Unframed(4) or t1Unframed(7).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER e1(0), e1Crc(1), e1Cas(2), e1CasCrc(3), e1Unframed(4), t1Esf(5), t1D4(6), t1Unframed(7)  

optT1E1RecoverTime 1.3.6.1.4.1.644.2.4.2.7.1.2.1.7
This is the red alarm timeout value. Determines the amount of seconds the port will wait to stop sending the yellow alarm when coming out of a red alarm condition.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER timeout-3-secs(3), timeout-10-secs(10), timeout-15-secs(15)  

optT1E1EsfFormat 1.3.6.1.4.1.644.2.4.2.7.1.2.1.8
Determines the type of ESF network commands the T-1 link will respond to. It has no meaning for D4 or E1 networks. With ESF networks, this information must be obtained from the network supplier.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER att-54016(0), ansi-t1-403(1)  

optT1E1UnusedTSs 1.3.6.1.4.1.644.2.4.2.7.1.2.1.9
Determines the whether the code that will be transmitted over the unused timeslots will be 'idle' or 'busy' (all 1's).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER busy(0), idle(1)  

optT1E1CfgCmdStatus 1.3.6.1.4.1.644.2.4.2.7.1.2.1.10
The command status for this link configuration row/record. The value used in a SET will be replaced by a response value in the GET RESPONSE indicating success or failure. Default Response State used in GET RESPONSE Command ready-for-command (0) initial default status for a row optical T1E1 Link Commands used in SET Command (1..199) update(1) Change existing Link Configuration inServiceAll (7) Change Link Status to in-service for all links within the same payload. copyToAll (9) Copy T1/E1 Link configuration to all other links within the same payload outOfServiceAll (12) Change Link Status to out-of-service for all links within the same payload. Response States used in GET RESPONSE Command (100..199) update-successful (101) Link data has been successfully changed insvc-successful (107) All Payload Links have been successfully placed In Service copy-successful (109) Link data has been successfully copied to other links oos-successful (112) All Payload Links have been successfully placed Out of Service optical T1E1 Link Config Error Codes used in GET RESPONSE Command (400..699) err-general-link-config-error (400) Unknown link configuration error occurred err-invalid-link-status (401) Unrecognized link status setting err-invalid-link-framing (402) Line framing type not valid for link type err-invalid-link-command (403) Unrecognized link command-action err-invalid-esf-format (405) ESF type not applicable to link type err-invalid-red-timeout (412) Unrecognized red alarm timeout err-invalid-idle-code (413) Unrecognized unused TSs code err-device-in-standby (414) Can't change config for designated Standby device err-data-locked-by-another-user (450) Another administrative user is making changes to this part of the system via a terminal session. Check Event Log for user name err-snmp-parse-failed (500) Agent could not parse variable err-invalid-snmp-type (501) Variable ASN type does not match Agent defined type err-invalid-snmp-var-size (502) Variable size is too big
Status: current Access: read-write
OBJECT-TYPE    
  LinkCmdStatus  

optT1E1NationalBits 1.3.6.1.4.1.644.2.4.2.7.1.2.1.11
Enables E1 National S-bits to be set to zero or one. This single byte field can be changed to set the values of the E1 NFA byte in odd frames as depicted below: sa8 sa7 sa6 sa5 sa4 reserved bits --- --- --- --- --- ------------- 1 1 1 1 1 0 0 0 = F8 (default) Values should be entered in Hex. If reserved bits are changed, an error code (427) will be returned in the command status.
Status: current Access: read-write
OBJECT-TYPE    
  OneByteField  

optT1E1InterNational 1.3.6.1.4.1.644.2.4.2.7.1.2.1.12
Enables InterNational S(i) Spare bit to be set to zero or one. This single byte field can be changed to set the values of the Bit 1 of TS0 G.704 frame as depicted below: reserved bits S(i) -------------------------- ----- 0 0 0 0 0 0 0 1 = 01 (default) Values should be entered in Hex. If reserved bits are changed, an error code (427) will be returned in the command status.
Status: current Access: read-write
OBJECT-TYPE    
  OneByteField  

opticalTUStatusTable 1.3.6.1.4.1.644.2.4.2.7.2.1
This is the Stm1Oc3 Tributary Unit Status table which consists of an entry for each of the card's 84 links. The total number of entries depends on the number of STM1/OC3 cards in the Node.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OpticalTUStatusEntry

opticalTUStatusEntry 1.3.6.1.4.1.644.2.4.2.7.2.1.1
The conceptual row of the Stm1Oc3 Tributary Unit Status table. A row in this table cannot be added or deleted, only modified.
Status: current Access: not-accessible
OBJECT-TYPE    
  OpticalTUStatusEntry  

optTUStatusAddr 1.3.6.1.4.1.644.2.4.2.7.2.1.1.1
This number uniquely identifies a Stm1Oc3 TU link. This number will be used throughout the system to identify a unique resource.
Status: current Access: read-only
OBJECT-TYPE    
  LinkPortAddress  

optTUStatusResrcId 1.3.6.1.4.1.644.2.4.2.7.2.1.1.2
This number uniquely identifies a Stm1Oc3 TU resource. This number is provided as key to allow the manager to map this entry to a corresponding Resource Table entry.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optTUStatusLinkState 1.3.6.1.4.1.644.2.4.2.7.2.1.1.3
Determines the current STM1/OC3 Tributary Unit status of the link. ok (0) - In Sync yel (2) - Yellow Alarm ais (8) - Sending All Ones lof (32) - Loss of Frame los (64) - Loss of Signal red (2048) - Red Alarm cfa (4096) - Carrier Frame Alignment oos (65535) - Out of Service txSlip (2097152) - Transmit Slip rxSlip (4194304) - Receive Slip sef (8388608) - Severely Errored Frames slip (6291456) - Transmit/Receive Slip underTest(1073741824) - Running Bit Error Test (BERT) errors (2147483647) - Multiple Errors displays raw bit field value
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER ok(0), yel(2), ais(8), lof(32), los(64), red(2048), cfa(4096), oos(65535), txSlip(2097152), rxSlip(4194304), sef(8388608), slip(6291456), underTest(1073741824), errors(2147483647)  

optTUStatusErrSecs 1.3.6.1.4.1.644.2.4.2.7.2.1.1.4
This is the total number of Errored Seconds for the Tributary Unit.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

optTUStatusAisErrs 1.3.6.1.4.1.644.2.4.2.7.2.1.1.5
This is the total number of TU Alarm Indication Signal Errored Seconds.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

optTUStatusLopErrs 1.3.6.1.4.1.644.2.4.2.7.2.1.1.6
This is the total number of TU Loss of Pointer Errored Seconds.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

optTUStatusRdiTUErrs 1.3.6.1.4.1.644.2.4.2.7.2.1.1.7
This is the total number of TU Remote Defect Indication Errored Seconds.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

optTUStatusRfiTUErrs 1.3.6.1.4.1.644.2.4.2.7.2.1.1.8
This is the total number of TU Remote Failure Indication Errored Seconds.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

optTUStatusPSLMErrs 1.3.6.1.4.1.644.2.4.2.7.2.1.1.9
This is the total number of TU Path Signal Label Mismatch Errored Seconds.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

optTUStatusPSLUErrs 1.3.6.1.4.1.644.2.4.2.7.2.1.1.10
This is the total number of TU Path Signal Label Unstable Errored Seconds.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

optTUStatusErrFreeSecs 1.3.6.1.4.1.644.2.4.2.7.2.1.1.11
This is the total number of Error-Free seconds for the Tributary Unit.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

opticalMapperStatusTable 1.3.6.1.4.1.644.2.4.2.7.2.2
This is the Stm1Oc3 Mapper Status table which consists of an entry for each of the 3 STM1/OC3 Mapper Payloads. The total number of entries depends on the number of STM1/OC3 cards in the Node.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OpticalMapperStatusEntry

opticalMapperStatusEntry 1.3.6.1.4.1.644.2.4.2.7.2.2.1
The conceptual row of the Stm1Oc3 Mapper Status table. A row in this table cannot be added or deleted, only modified.
Status: current Access: not-accessible
OBJECT-TYPE    
  OpticalMapperStatusEntry  

optMapperStatusAddr 1.3.6.1.4.1.644.2.4.2.7.2.2.1.1
This number uniquely identifies a STM1/OC3 Mapper Payload. This number will be used throughout the system to identify a unique resource.
Status: current Access: read-only
OBJECT-TYPE    
  LinkPortAddress  

optMapperStatusResrcId 1.3.6.1.4.1.644.2.4.2.7.2.2.1.2
This number uniquely identifies a STM1/OC3 Mapper resource. This number is provided as key to allow the manager to map this entry to a corresponding Resource Table entry.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optMapperState 1.3.6.1.4.1.644.2.4.2.7.2.2.1.3
This number uniquely identifies the Mapper Payload State. ok (0) - In Sync yel (2) - Yellow Alarm ais (8) - Sending All Ones lop (16) - Loss of Ptr lof (32) - Loss of Frame los (64) - Loss of Signal rdi (128) - Receive Defect Indicator red (2048) - Red Alarm cfa (4096) - Carrier Frame Alignment oos (65535) - Out of Service txSlip (2097152) - Transmit Slip rxSlip (4194304) - Receive Slip sef (8388608) - Severely Errored Frames slip (6291456) - Transmit/Receive Slip underTest(1073741824) - Running Bit Error Test (BERT) errors (2147483647) - Multiple Errors displays raw bit field value
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER ok(0), yel(2), ais(8), lop(16), lof(32), los(64), rdi(128), red(2048), cfa(4096), oos(65535), txSlip(2097152), rxSlip(4194304), sef(8388608), slip(6291456), underTest(1073741824), errors(2147483647)  

optMapperErrSecs 1.3.6.1.4.1.644.2.4.2.7.2.2.1.4
This is the total number of Errored Seconds for this Mapper Payload.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

optMapperErrFreeSecs 1.3.6.1.4.1.644.2.4.2.7.2.2.1.5
This is the total number of Mapper Error Free Seconds.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

optMapperLoop 1.3.6.1.4.1.644.2.4.2.7.2.2.1.6
Indicates the loopback status of the Stm1Oc3 Mapper for this device.. off (0) - indicates loopback is disabled local (1) - indicates Mapper local data is looped back to itself line (3) - entire Mapper Frame is looped, framing is not regenerated
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(0), local(1), line(3)  

optMapperPathLOPErrs 1.3.6.1.4.1.644.2.4.2.7.2.2.1.7
This is the total number of Mapper Path Loss of Pointer Errored Seconds.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

optMapperPathAISErrs 1.3.6.1.4.1.644.2.4.2.7.2.2.1.8
This is the total number of Mapper Path Alarm Indication Signal Errored Seconds.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

optMapperPathRDIErrs 1.3.6.1.4.1.644.2.4.2.7.2.2.1.9
This is the total number of Mapper Path Remote Defect Indication Errored Seconds.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

optMapperCmdStatus 1.3.6.1.4.1.644.2.4.2.7.2.2.1.10
This is the command status for the Framer Row. The value used in a SET will be replaced by a response value in the GET RESPONSE indicating success or failure. Default Response State used in GET RESPONSE Command ready-for-command (0) initial default status for a row Mapper Action Commands used in SET Command (1..99) updateTest (1) Can be used optionally when activating loops and berts in order to get status code back in response clearErrors (14) Resets all error counters and bert test time to zero Response States used in GET RESPONSE Command (100..199) update-successful (101) Test action has been successfully performed clear-successful (114) Error counts have been successfully cleared The Error Codes used in GET RESPONSE Command (200..799) err-general-test-error (200) Unknown Test request error occurred. err-invalid-loop-type (202) Unrecognized loop selection err-field-cannot-be-set (206) Read-only field was included in SET request err-snmp-parse-failed (500) Agent could not parse variable err-invalid-snmp-type (501) Variable ASN type does not match Agent defined type err-invalid-snmp-var-size (502) Variable size is too big
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER ready-for-command(0), updateTest(1), clearErrors(14), update-successful(101), clear-successful(114), err-general-test-error(200), err-invalid-loop-type(202), err-field-cannot-be-set(206), err-snmp-parse-failed(500), err-invalid-snmp-type(501), err-invalid-snmp-var-size(502)  

opticalTransportStatusTable 1.3.6.1.4.1.644.2.4.2.7.2.3
This is the Stm1Oc3 Transport Status table which consists of an entry for each of the STM1/OC3 Transport Overhead. The total number of entries depends on the number of Stm1Oc3 cards in the Node.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    OpticalTransportStatusEntry

opticalTransportStatusEntry 1.3.6.1.4.1.644.2.4.2.7.2.3.1
The conceptual row of the Stm1Oc3 Transport Status table. A row in this table cannot be added or deleted, only modified.
Status: current Access: not-accessible
OBJECT-TYPE    
  OpticalTransportStatusEntry  

optTransportStatusAddr 1.3.6.1.4.1.644.2.4.2.7.2.3.1.1
This number uniquely identifies a STM1/OC3 Transport Overhead Nest and Slot number. This number format will be used throughout the system to identify a resource.
Status: current Access: read-only
OBJECT-TYPE    
  NestSlotAddress  

optTransportStatusResrcId 1.3.6.1.4.1.644.2.4.2.7.2.3.1.2
This number uniquely identifies a STM1/OC3 Transport resource. This number is provided as key to allow the manager to map this entry to a corresponding Resource Table entry.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

optTransportLaserState 1.3.6.1.4.1.644.2.4.2.7.2.3.1.3
This specifies the State of the Laser Interface.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(0), on(1)  

optTransportErrSecs 1.3.6.1.4.1.644.2.4.2.7.2.3.1.4
This is the total number of Errored Seconds for this Transport Overhead.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

optTransportErrFreeSecs 1.3.6.1.4.1.644.2.4.2.7.2.3.1.5
This is the total number of Transport Error Free Seconds.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

optTransportLoop 1.3.6.1.4.1.644.2.4.2.7.2.3.1.6
Indicates the loopback status of the Stm1Oc3 Transport for this device. off (0) - indicates Transport loopback is disabled terminal (1) - The optical line interface transmit driver is looped back to the optical receiver. Ultimately the payload is reflected back to the Switch Fabric and the PCM Highway of the DNX Backplane. facility (2) - The Fiber Optic path is looped back to the facility. pathFacility (3) - The Stm1Oc3 incoming data (Rx) is transmitted back to its source via the Tx path. The bus that interfaces to the mappers is in loopback, and the entire payload is returned to its source with a refreshed frame structure.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(0), terminal(1), facility(2), pathFacility(3)  

optTransportLineAISErrs 1.3.6.1.4.1.644.2.4.2.7.2.3.1.7
This is the total number of Transport Line Alarm Indication Signal Errored Seconds.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

optTransportLineRDIErrs 1.3.6.1.4.1.644.2.4.2.7.2.3.1.8
This is the total number of Transport Line Remote Defect Indication Errored Seconds.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

optTransportLineOOFErrs 1.3.6.1.4.1.644.2.4.2.7.2.3.1.9
This is the total number of Transport Line Out of Frame Errored Seconds.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

optTransportLineLOFErrs 1.3.6.1.4.1.644.2.4.2.7.2.3.1.10
This is the total number of Transport Line Loss of Frame Errored Seconds.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

optTransportLineLOSErrs 1.3.6.1.4.1.644.2.4.2.7.2.3.1.11
This is the total number of Transport Line Loss of Signal Errored Seconds.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

optTransportCmdStatus 1.3.6.1.4.1.644.2.4.2.7.2.3.1.12
This is the command status for the Framer Row. The value used in a SET will be replaced by a response value in the GET RESPONSE indicating success or failure. Default Response State used in GET RESPONSE Command ready-for-command (0) initial default status for a row Transport Action Commands used in SET Command (1..99) updateTest (1) Can be used optionally when activating loops and berts in order to get status code back in response clearErrors (14) Resets all error counters and bert test time to zero Response States used in GET RESPONSE Command (100..199) update-successful (101) Test action has been successfully performed clear-successful (114) Error counts have been successfully cleared The Error Codes used in GET RESPONSE Command (400..799) err-general-test-error (400) Unknown Test request error occurred. err-invalid-loop-type (402) Unrecognized loop selection err-field-cannot-be-set (406) Read-only field was included in SET request err-snmp-parse-failed (500) Agent could not parse variable err-invalid-snmp-type (501) Variable ASN type does not match Agent defined type err-invalid-snmp-var-size (502) Variable size is too big
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER ready-for-command(0), updateTest(1), clearErrors(14), update-successful(101), clear-successful(114), err-general-test-error(400), err-invalid-loop-type(402), err-field-cannot-be-set(406), err-snmp-parse-failed(500), err-invalid-snmp-type(501), err-invalid-snmp-var-size(502)  

dnxStm1Oc3Enterprise 1.3.6.1.4.1.644.2.4.2.7.0
ERI DNX Stm1Oc3 Device Enterprise for Alarms/Events
Status: current Access: read-write
OBJECT-IDENTITY    

optDevConfigTrap 1.3.6.1.4.1.644.2.4.2.7.0.1
This trap is used to notify a NMS that a user has updated the configuration for a given Stm1Oc3 Device entry.
Status: current Access: read-write
NOTIFICATION-TYPE    

optT1E1ConfigTrap 1.3.6.1.4.1.644.2.4.2.7.0.2
This trap is used to notify a NMS that a user has updated the configuration for a given Stm1Oc3 T1/E1 Link entry.
Status: current Access: read-write
NOTIFICATION-TYPE