EQUIPE-SONET-MIB
File:
EQUIPE-SONET-MIB.mib (10459 bytes)
Imported modules
Imported symbols
Defined Types
EqSonetApsCfgStatus |
|
Equipe sonet aps config status values. |
TEXTUAL-CONVENTION |
|
|
|
|
INTEGER |
none(1), working(2), protecting(3), lockoutProtecting(4), forcedSwitchWorkingToProtecting(5), forcedSwitchProtectingToWorking(6), manualSwitchWorkingToProtecting(7), manualSwitchProtectingToWorking(8) |
|
EqSonetApsCfgAction |
|
Equipe sonet aps config action values. |
TEXTUAL-CONVENTION |
|
|
|
|
INTEGER |
other(1), clear(2), lockoutProtecting(3), forcedSwitchWorkingToProtecting(4), forcedSwitchProtectingToWorking(5), manualSwitchWorkingToProtecting(6), manualSwitchProtectingToWorking(7) |
|
EqSonetApsCfgEntry |
|
SEQUENCE |
|
|
|
|
eqSonetApsCfgStatus |
EqSonetApsCfgStatus |
|
|
eqSonetApsCfgAction |
EqSonetApsCfgAction |
|
|
eqSonetApsCfgLastAction |
EqSonetApsCfgAction |
|
|
eqSonetApsCfgPortActive |
INTEGER |
|
EqSonetPathEntry |
|
SEQUENCE |
|
|
|
|
eqSonetPathActualPort |
INTEGER |
|
EqSonetStatsEntry |
|
SEQUENCE |
|
|
|
|
eqSonetStatsIfIndex |
INTEGER |
|
|
eqSonetStatsLineFailures |
Counter32 |
|
|
eqSonetStatsLineApsCount |
Counter32 |
|
|
eqSonetStatsLineApsSwitchDuration |
Counter32 |
|
|
eqSonetStatsLineStsPtrAdjustments |
Counter32 |
|
|
eqSonetStatsPathFailures |
Counter32 |
|
|
eqSonetStatsTimeElapsed |
Integer32 |
|
Defined Values
equipe |
1.3.6.1.4.1.5022 |
OBJECT IDENTIFIER |
|
|
|
eqSonetMib |
1.3.6.1.4.1.5022.3 |
This is the Equipe SONET MIB module. |
MODULE-IDENTITY |
|
|
|
eqSonetApsCfgEntry |
1.3.6.1.4.1.5022.3.1.1 |
A sonet port aps config entry. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
EqSonetApsCfgEntry |
|
|
eqSonetApsCfgAction |
1.3.6.1.4.1.5022.3.1.1.2 |
This object is used to perform an aps action on a sonet port.
A read on this object always returns the value other(1).
Setting this object to clear(2) causes the port to revert
back to default aps configuration.
Setting this object to lockoutProtecting(3) prevents any
of the working channels from switching to the protecting
line.
Setting this object to forcedSwitchWorkingToProtecting(4)
switches the working port to the protecting port.
Setting this object to forcedSwitchProtectingToWorking(5)
switches the protecting port to the working port.
Setting this object to manualSwitchWorkingToProtecting(6)
switches the working port to the protecting port.
Setting this object to manualSwitchProtectingToWorking(7)
switches the protecting port to the working port. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
EqSonetApsCfgAction |
|
|
eqSonetApsCfgPortActive |
1.3.6.1.4.1.5022.3.1.1.4 |
This object is used to determine if the sts paths configured
on this port are currrently actually terminated on this port.
This is used to determine if the port is in active or standby
mode. A value of false(1) indicates that the sts paths are
not terminated (standby). A value of true(2) indicates
that the sts paths are terminated (active). |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
false(1), true(2) |
|
eqSonetPathTable |
1.3.6.1.4.1.5022.3.2 |
This table contains config info for a sonet port. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
EqSonetPathEntry |
|
eqSonetPathEntry |
1.3.6.1.4.1.5022.3.2.1 |
A sonet path config entry. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
EqSonetPathEntry |
|
|
eqSonetPathActualPort |
1.3.6.1.4.1.5022.3.2.1.1 |
The ifIndex of the sonet port over which this path is
actually running. Note that this value could be different
from the sonet port that the sts path was originally
configured. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
1..2147483647 |
|
eqSonetStatsEntry |
1.3.6.1.4.1.5022.3.3.1 |
A sonet port stats entry. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
EqSonetStatsEntry |
|
|
eqSonetStatsIfIndex |
1.3.6.1.4.1.5022.3.3.1.1 |
The ifIndex for the corresponding sonet port. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
1..2147483647 |
|
eqSonetStatsLineFailures |
1.3.6.1.4.1.5022.3.3.1.2 |
The number of line failure events. A line failure is an
AIS-L signal received from another NE, or received from
the same NE when internally generating an AIS-L signal
in the LTE. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter32 |
|
|
eqSonetStatsLineApsCount |
1.3.6.1.4.1.5022.3.3.1.3 |
The number of times the service has switched from the
working to the protect line. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter32 |
|
|
eqSonetStatsLineStsPtrAdjustments |
1.3.6.1.4.1.5022.3.3.1.5 |
The count of STS pointer adjustments created or absorbed
by an NE due to differences in the frame rates of the
incoming and outgoing sonet signal. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter32 |
|
|
eqSonetStatsPathFailures |
1.3.6.1.4.1.5022.3.3.1.6 |
The number of path failure events. A path failure is an
AIS-P signal received from another NE, or received from
the same NE when internally generating an AIS-P signal
in the PTE. A path with support for ERDI-P will increment
this counter when an UNEQ-P failure is declared. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Counter32 |
|
|
eqSonetStatsTimeElapsed |
1.3.6.1.4.1.5022.3.3.1.7 |
The number of seconds, including partial seconds,
that have elapsed since the beginning of the current
measurement period. If, for some reason, such as an
adjustment in the system's time-of-day clock, the
current interval exceeds the maximum value, the
agent will return the maximum value. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
1..900 |
|