EQUIPE-SONET-MIB

File: EQUIPE-SONET-MIB.mib (10459 bytes)

Imported modules

SNMPv2-TC RFC1155-SMI IF-MIB
SNMPv2-SMI

Imported symbols

TEXTUAL-CONVENTION enterprises ifIndex
Integer32 MODULE-IDENTITY OBJECT-TYPE
Counter32

Defined Types

EqSonetApsCfgStatus  
Equipe sonet aps config status values.
TEXTUAL-CONVENTION    
  INTEGER none(1), working(2), protecting(3), lockoutProtecting(4), forcedSwitchWorkingToProtecting(5), forcedSwitchProtectingToWorking(6), manualSwitchWorkingToProtecting(7), manualSwitchProtectingToWorking(8)  

EqSonetApsCfgAction  
Equipe sonet aps config action values.
TEXTUAL-CONVENTION    
  INTEGER other(1), clear(2), lockoutProtecting(3), forcedSwitchWorkingToProtecting(4), forcedSwitchProtectingToWorking(5), manualSwitchWorkingToProtecting(6), manualSwitchProtectingToWorking(7)  

EqSonetApsCfgEntry  
SEQUENCE    
  eqSonetApsCfgStatus EqSonetApsCfgStatus
  eqSonetApsCfgAction EqSonetApsCfgAction
  eqSonetApsCfgLastAction EqSonetApsCfgAction
  eqSonetApsCfgPortActive INTEGER

EqSonetPathEntry  
SEQUENCE    
  eqSonetPathActualPort INTEGER

EqSonetStatsEntry  
SEQUENCE    
  eqSonetStatsIfIndex INTEGER
  eqSonetStatsLineFailures Counter32
  eqSonetStatsLineApsCount Counter32
  eqSonetStatsLineApsSwitchDuration Counter32
  eqSonetStatsLineStsPtrAdjustments Counter32
  eqSonetStatsPathFailures Counter32
  eqSonetStatsTimeElapsed Integer32

Defined Values

equipe 1.3.6.1.4.1.5022
OBJECT IDENTIFIER    

eqSonetMib 1.3.6.1.4.1.5022.3
This is the Equipe SONET MIB module.
MODULE-IDENTITY    

eqSonetApsCfgTable 1.3.6.1.4.1.5022.3.1
This table contains aps config info for a sonet port.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    EqSonetApsCfgEntry

eqSonetApsCfgEntry 1.3.6.1.4.1.5022.3.1.1
A sonet port aps config entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  EqSonetApsCfgEntry  

eqSonetApsCfgStatus 1.3.6.1.4.1.5022.3.1.1.1
The current aps status for this sonet port.
Status: current Access: read-only
OBJECT-TYPE    
  EqSonetApsCfgStatus  

eqSonetApsCfgAction 1.3.6.1.4.1.5022.3.1.1.2
This object is used to perform an aps action on a sonet port. A read on this object always returns the value other(1). Setting this object to clear(2) causes the port to revert back to default aps configuration. Setting this object to lockoutProtecting(3) prevents any of the working channels from switching to the protecting line. Setting this object to forcedSwitchWorkingToProtecting(4) switches the working port to the protecting port. Setting this object to forcedSwitchProtectingToWorking(5) switches the protecting port to the working port. Setting this object to manualSwitchWorkingToProtecting(6) switches the working port to the protecting port. Setting this object to manualSwitchProtectingToWorking(7) switches the protecting port to the working port.
Status: current Access: read-write
OBJECT-TYPE    
  EqSonetApsCfgAction  

eqSonetApsCfgLastAction 1.3.6.1.4.1.5022.3.1.1.3
This object indicates the last aps action requested on this port.
Status: current Access: read-only
OBJECT-TYPE    
  EqSonetApsCfgAction  

eqSonetApsCfgPortActive 1.3.6.1.4.1.5022.3.1.1.4
This object is used to determine if the sts paths configured on this port are currrently actually terminated on this port. This is used to determine if the port is in active or standby mode. A value of false(1) indicates that the sts paths are not terminated (standby). A value of true(2) indicates that the sts paths are terminated (active).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER false(1), true(2)  

eqSonetPathTable 1.3.6.1.4.1.5022.3.2
This table contains config info for a sonet port.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    EqSonetPathEntry

eqSonetPathEntry 1.3.6.1.4.1.5022.3.2.1
A sonet path config entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  EqSonetPathEntry  

eqSonetPathActualPort 1.3.6.1.4.1.5022.3.2.1.1
The ifIndex of the sonet port over which this path is actually running. Note that this value could be different from the sonet port that the sts path was originally configured.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..2147483647  

eqSonetStatsTable 1.3.6.1.4.1.5022.3.3
This table contains stats for a sonet port.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    EqSonetStatsEntry

eqSonetStatsEntry 1.3.6.1.4.1.5022.3.3.1
A sonet port stats entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  EqSonetStatsEntry  

eqSonetStatsIfIndex 1.3.6.1.4.1.5022.3.3.1.1
The ifIndex for the corresponding sonet port.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..2147483647  

eqSonetStatsLineFailures 1.3.6.1.4.1.5022.3.3.1.2
The number of line failure events. A line failure is an AIS-L signal received from another NE, or received from the same NE when internally generating an AIS-L signal in the LTE.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

eqSonetStatsLineApsCount 1.3.6.1.4.1.5022.3.3.1.3
The number of times the service has switched from the working to the protect line.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

eqSonetStatsLineApsSwitchDuration 1.3.6.1.4.1.5022.3.3.1.4
The number of seconds the service has been carried on the protection line.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

eqSonetStatsLineStsPtrAdjustments 1.3.6.1.4.1.5022.3.3.1.5
The count of STS pointer adjustments created or absorbed by an NE due to differences in the frame rates of the incoming and outgoing sonet signal.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

eqSonetStatsPathFailures 1.3.6.1.4.1.5022.3.3.1.6
The number of path failure events. A path failure is an AIS-P signal received from another NE, or received from the same NE when internally generating an AIS-P signal in the PTE. A path with support for ERDI-P will increment this counter when an UNEQ-P failure is declared.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

eqSonetStatsTimeElapsed 1.3.6.1.4.1.5022.3.3.1.7
The number of seconds, including partial seconds, that have elapsed since the beginning of the current measurement period. If, for some reason, such as an adjustment in the system's time-of-day clock, the current interval exceeds the maximum value, the agent will return the maximum value.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..900