EFDATA-SPECTRACAST-DR5000-MIB
File:
EFDATA-SPECTRACAST-DR5000-MIB.mib (15495 bytes)
Imported modules
Imported symbols
Defined Types
FLAG |
|
INTEGER |
on(1), off(2) |
|
|
PIDentry |
|
SEQUENCE |
|
|
|
|
pidindex |
INTEGER |
|
|
pidvalue |
INTEGER |
|
Defined Values
efdata |
1.3.6.1.4.1.6247 |
OBJECT IDENTIFIER |
|
|
|
dr5000 |
1.3.6.1.4.1.6247.3.2 |
OBJECT IDENTIFIER |
|
|
|
general |
1.3.6.1.4.1.6247.3.2.1 |
OBJECT IDENTIFIER |
|
|
|
macAddress |
1.3.6.1.4.1.6247.3.2.1.3 |
MAC address (read only). |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
lnb-Frequency |
1.3.6.1.4.1.6247.3.2.2.2 |
LNB frequency (GHz) (read-write). |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
symbolRate |
1.3.6.1.4.1.6247.3.2.2.3 |
Symbol rate (Msps) (read-write). |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
polarity |
1.3.6.1.4.1.6247.3.2.2.4 |
Polarity may take values: Disabled(0), Vertical(14) or Horizontal(18) (read-write). |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
disabled(0), vertical(14), horizontal(18) |
|
frequencyRange |
1.3.6.1.4.1.6247.3.2.2.5 |
Frequency range may take values: Low(0) or High(1) (read-write). |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
low(0), high(1) |
|
pids-number |
1.3.6.1.4.1.6247.3.2.3.1 |
Number of PIDs in the list (read only). |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
pidTable |
1.3.6.1.4.1.6247.3.2.3.2 |
List of PID entries. The number of entries is given by PIDs-number value. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
PIDentry |
|
pidEntry |
1.3.6.1.4.1.6247.3.2.3.2.1 |
PID entry containing objects for the particular PID. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
PIDentry |
|
|
pidindex |
1.3.6.1.4.1.6247.3.2.3.2.1.1 |
Unique ID for each PID, ranges between 1 and PIDs-number (read-only). |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
pidvalue |
1.3.6.1.4.1.6247.3.2.3.2.1.2 |
Unique PID value (read-write). |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
ccuConnectionMode |
1.3.6.1.4.1.6247.3.2.4.1 |
CCU connection mode, may take values: Manual(0), Duplex(1) or Simplex(2) (read-write). |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
manual(0), duplex(1), simplex(2) |
|
ccuIpAddress |
1.3.6.1.4.1.6247.3.2.4.2 |
CCU IP Address (read-write). |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
IpAddress |
|
|
ccuUserName |
1.3.6.1.4.1.6247.3.2.4.3 |
User name for connecting to the CCU (write only). |
Status: mandatory |
Access: write-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
ccuPassword |
1.3.6.1.4.1.6247.3.2.4.4 |
Password for connecting to the CCU (write only). |
Status: mandatory |
Access: write-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
encryptedMulticast |
1.3.6.1.4.1.6247.3.2.4.5 |
Set to Enabled in order to receive encrypted multicast. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
disabled(0), enabled(1) |
|
connectionMode |
1.3.6.1.4.1.6247.3.2.5.1 |
Connection Mode, may take values: Manual(0) or Automatic(1) (read-write). |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
manual(0), automatic(1) |
|
phoneNumber |
1.3.6.1.4.1.6247.3.2.5.2 |
ISP Phone number, accepts only digits (read-write). |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
userName |
1.3.6.1.4.1.6247.3.2.5.3 |
User name for dialup connection (write only). |
Status: mandatory |
Access: write-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
password |
1.3.6.1.4.1.6247.3.2.5.4 |
Password for dialup connection (write only). |
Status: mandatory |
Access: write-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
dialTone |
1.3.6.1.4.1.6247.3.2.5.5 |
Dialing mode, may take values: Tone(0)) or Pulse(1) (read-write). |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
tone(0), pulse(1) |
|
speed |
1.3.6.1.4.1.6247.3.2.5.7 |
Modem connection speed, may take values: 9600, 19200, 38400, 57600 or 115200 (read-write). |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
idleTimeOut |
1.3.6.1.4.1.6247.3.2.5.8 |
Dial on demand time out in minutes.
Set to 0 in order to disable dial on demand (read-write). |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
authentication |
1.3.6.1.4.1.6247.3.2.5.9 |
Authentication mode, may take values: PAP or CHAP (read-write). |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
pap(0), chap(1) |
|
status |
1.3.6.1.4.1.6247.3.2.6 |
OBJECT IDENTIFIER |
|
|
|
fec |
1.3.6.1.4.1.6247.3.2.6.5 |
FEC (read only). |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
agc |
1.3.6.1.4.1.6247.3.2.6.6 |
Gain value set by AGC (Db) (read only). |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
eb-N0 |
1.3.6.1.4.1.6247.3.2.6.8 |
Eb/N0 (read only). |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
ccu-connection-status |
1.3.6.1.4.1.6247.3.2.6.9 |
CCU connection status, may take values Disconnected(0), Connected(1), Trying to Connect(2),
Waiting for Dialup(3), or Waiting for RF Lock(4) (read only). |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
disconnected(0), connected(1), tryingtoconnect(2), waitingfordialup(3), waitingforrflock(4) |
|
dialup-connection-status |
1.3.6.1.4.1.6247.3.2.6.10 |
Dialup connection status, may take values Disconnected(0), Connected(1), Trying to Connect(2)
or Idle(10) (read only). |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
disconnected(0), connected(1), tryingtoconnect(2), idle(10) |
|
totalThroughput |
1.3.6.1.4.1.6247.3.2.7.1 |
Total throughput in bytes/sec. (read only). |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
unicastThroughput |
1.3.6.1.4.1.6247.3.2.7.2 |
Unicast throughput in bytes/sec. (read only). |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
totalPackets |
1.3.6.1.4.1.6247.3.2.7.4 |
Total packets received since reset (read only). |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
badPackets |
1.3.6.1.4.1.6247.3.2.7.5 |
Bad RS packets (read only). |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
resetFlowStatistics |
1.3.6.1.4.1.6247.3.2.7.7 |
Set to True in order to reset flow statistics. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
false(0), true(1) |
|
maintenance |
1.3.6.1.4.1.6247.3.2.8 |
OBJECT IDENTIFIER |
|
|
|
driverRestart |
1.3.6.1.4.1.6247.3.2.8.1 |
Set to True in order to restart the Driver. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
false(0), true(1) |
|
dialupConnect |
1.3.6.1.4.1.6247.3.2.8.2 |
Set to True in order to dial your ISP. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
false(0), true(1) |
|
dialupDisconnect |
1.3.6.1.4.1.6247.3.2.8.3 |
Set to true in order to disconnect from your ISP. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
false(0), true(1) |
|
ccuconnect |
1.3.6.1.4.1.6247.3.2.8.4 |
Set to True in order to connect to the CCU. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
false(0), true(1) |
|
ccudisconnect |
1.3.6.1.4.1.6247.3.2.8.5 |
Set to True in order to disconnect from the CCU. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
false(0), true(1) |
|
upgrade |
1.3.6.1.4.1.6247.3.2.8.6 |
Set to the upgrade file name, and upgrade the system.
After upgrade finishes the system reboots automatically (write only). |
Status: mandatory |
Access: write-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
enableTraps |
1.3.6.1.4.1.6247.3.2.9.1 |
Set to True in order to start getting traps. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
disable(0), enable(1) |
|
snmpManagerIP |
1.3.6.1.4.1.6247.3.2.9.2 |
IP address of SNMP manager where traps have to be sent to (read-write). |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
IpAddress |
|
|
trapPeriod |
1.3.6.1.4.1.6247.3.2.9.3 |
Trap sending period in seconds (read-write). |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
trapList |
1.3.6.1.4.1.6247.3.2.9.4 |
OBJECT IDENTIFIER |
|
|
|
multicastTrapEnable |
1.3.6.1.4.1.6247.3.2.9.4.1.1 |
Use multicast daemon status trap. A trap message is sent when multicast
daemon goes down (read-write). |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
disable(0), enable(1) |
|
demodulator |
1.3.6.1.4.1.6247.3.2.9.4.2 |
OBJECT IDENTIFIER |
|
|
|
demodulatorTrapEnable |
1.3.6.1.4.1.6247.3.2.9.4.2.1 |
Use demodulator status trap. A trap message is sent when the demodulator
loses data lock (read-write). |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
disable(0), enable(1) |
|
ccuTrapEnable |
1.3.6.1.4.1.6247.3.2.9.4.3.1 |
Use CCU connection status trap. A trap message is sent when CCU status changes from
Connected to any other one (read-write). |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
disable(0), enable(1) |
|
dialup |
1.3.6.1.4.1.6247.3.2.9.4.4 |
OBJECT IDENTIFIER |
|
|
|
dialupTrapEnable |
1.3.6.1.4.1.6247.3.2.9.4.4.1 |
Use dialup connection status trap. A trap message is sent when dialup status changes
from Connected to any other one except Idle (read-write). |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
disable(0), enable(1) |
|
berLevel |
1.3.6.1.4.1.6247.3.2.9.4.5 |
OBJECT IDENTIFIER |
|
|
|
berTrapEnable |
1.3.6.1.4.1.6247.3.2.9.4.5.1 |
Use BER level trap. A trap message is sent when BER value is greater
then BER trap threshold (read-write). |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
disable(0), enable(1) |
|
berThreshold |
1.3.6.1.4.1.6247.3.2.9.4.5.2 |
BER level threshold value (read-write). |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
freqOffset |
1.3.6.1.4.1.6247.3.2.9.4.6 |
OBJECT IDENTIFIER |
|
|
|
freqOffsetTrapEnable |
1.3.6.1.4.1.6247.3.2.9.4.6.1 |
Use frequency offset trap. A trap message is sent when absolute frequency offset is greater
then frequency offset trap threshold (read-write). |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
disable(0), enable(1) |
|
freqOffsetThreshold |
1.3.6.1.4.1.6247.3.2.9.4.6.2 |
Frequency offset threshold value (read-write). |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
agcLevel |
1.3.6.1.4.1.6247.3.2.9.4.7 |
OBJECT IDENTIFIER |
|
|
|
agcTrapEnable |
1.3.6.1.4.1.6247.3.2.9.4.7.1 |
Use AGC level trap. A trap message is sent when gain value is greater
then AGC trap threshold (read-write). |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
disable(0), enable(1) |
|
agcThreshold |
1.3.6.1.4.1.6247.3.2.9.4.7.2 |
AGC threshold value (read-write) |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|