DLINKSW-STP-EXT-MIB

File: DLINKSW-STP-EXT-MIB.mib (11559 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC SNMPv2-CONF
IEEE8021-TC-MIB DLINK-ID-REC-MIB

Imported symbols

MODULE-IDENTITY OBJECT-TYPE Unsigned32
TruthValue MODULE-COMPLIANCE OBJECT-GROUP
IEEE8021BridgePortNumber IEEE8021MstIdentifier dlinkIndustrialCommon

Defined Types

DStpExtPortEntry  
SEQUENCE    
  dStpExtPortNumber IEEE8021BridgePortNumber
  dStpExtPortForwardBpduEnabled TruthValue
  dStpExtPortAdminHelloTime Unsigned32
  dStpExtPortState INTEGER

DStpExtMstpPortEntry  
SEQUENCE    
  dStpExtMstpPortMstId IEEE8021MstIdentifier
  dStpExtMstpPortNum IEEE8021BridgePortNumber
  dStpExtMstpPortRole INTEGER

Defined Values

dlinkSwStpExtMIB 1.3.6.1.4.1.171.14.15
The MIB module for managing D-Link STP extensions which are not covered by standard MIBs.
MODULE-IDENTITY    

dStpExtMIBNotifications 1.3.6.1.4.1.171.14.15.0
OBJECT IDENTIFIER    

dStpExtMIBObjects 1.3.6.1.4.1.171.14.15.1
OBJECT IDENTIFIER    

dStpExtMIBConformance 1.3.6.1.4.1.171.14.15.2
OBJECT IDENTIFIER    

dStpExtGblMgmt 1.3.6.1.4.1.171.14.15.1.1
OBJECT IDENTIFIER    

dStpExtStpGblStateEnabled 1.3.6.1.4.1.171.14.15.1.1.1
This object enables global spanning-tree function.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

dStpExtNotificationEnable 1.3.6.1.4.1.171.14.15.1.1.2
This object indicates whether a specified notification is enabled or not. If a bit corresponding to a notification is set to 1, then the specified notification can be generated. newRoot(0) - the newRoot notification as defined in BRIDGE-MIB. topologyChange(1) -- the topologyChange notification as defined in BRIDGE-MIB.
Status: current Access: read-write
OBJECT-TYPE    
  BITS newRoot(0), topologyChange(1)  

dStpExtStpNniBpduAddress 1.3.6.1.4.1.171.14.15.1.1.3
Specifies the BPDU MAC address of the NNI port in Q-in-Q status. dot1d - Use Customer Bridge Group Address (01-80-C2-00-00-00) as destination address of STP BPDU. dot1ad - Use Provider Bridge Group Address (01-80-C2-00-00-08) as destination address of STP BPDU.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER dot1d(1), dot1ad(2)  

dStpExtPortMgmt 1.3.6.1.4.1.171.14.15.1.2
OBJECT IDENTIFIER    

dStpExtPortTable 1.3.6.1.4.1.171.14.15.1.2.1
A table that contains port-specific information for the STP extensions.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DStpExtPortEntry

dStpExtPortEntry 1.3.6.1.4.1.171.14.15.1.2.1.1
An entry in dStpExtPortTable. This object indicates per port STP information which is not covered by standard MIB(s).
Status: current Access: not-accessible
OBJECT-TYPE    
  DStpExtPortEntry  

dStpExtPortNumber 1.3.6.1.4.1.171.14.15.1.2.1.1.1
The port number of the port for this entry.
Status: current Access: not-accessible
OBJECT-TYPE    
  IEEE8021BridgePortNumber  

dStpExtPortForwardBpduEnabled 1.3.6.1.4.1.171.14.15.1.2.1.1.2
This object indicates whether forward the received STP BPDUs to all VLAN member ports in untagged form. dStpExtPortForwardBpduEnabled cannot be set to 'true' when spanning-tree protocol is enabled on the interface.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

dStpExtPortAdminHelloTime 1.3.6.1.4.1.171.14.15.1.2.1.1.3
This object indicates the time interval to send one BPDU at the designated port. dStpExtPortAdminHelloTime only takes effect in MSTP mode.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 1..2  

dStpExtPortState 1.3.6.1.4.1.171.14.15.1.2.1.1.4
This object indicates the state of STP port. errDisabled(1): the port is at error disabled state. blocking(2) - broken(6): When STP is enabled on the port and the port is not at error disabled state, dStpExtPortState has the same value as dot1dStpPortState, as defined by application of STP. noStpForwarding(7) - STP is disabled at the port and this port is functioning. nonStpOther(8) - STP is disabled at the port and this port is link-down or other malfunctioning situations.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER errDisabled(1), blocking(2), listening(3), learning(4), forwarding(5), broken(6), nonStpForwarding(7), nonStpOther(8)  

dStpExtMstpMgmt 1.3.6.1.4.1.171.14.15.1.3
OBJECT IDENTIFIER    

dStpExtMstpPortTable 1.3.6.1.4.1.171.14.15.1.3.1
A table that contains MSTI-specific information which are not covered by ieee8021MstpPortTable. Note that entries will exist in this table only for bridge components for which the corresponding instance of ieee8021SpanningTreeVersion (from the IEEE8021-SPANNING-TREE-MIB) has a value of mstp(2) and the corresponding port is not disabled.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    DStpExtMstpPortEntry

dStpExtMstpPortEntry 1.3.6.1.4.1.171.14.15.1.3.1.1
An entry in dStpExtMstPortTable, which consists of information is not covered by ieee8021MstpPortTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  DStpExtMstpPortEntry  

dStpExtMstpPortMstId 1.3.6.1.4.1.171.14.15.1.3.1.1.1
In an MSTP Bridge, this parameter is the MSTID, i.e. the identifier of a Spanning Tree (or MST) Instance.
Status: current Access: not-accessible
OBJECT-TYPE    
  IEEE8021MstIdentifier  

dStpExtMstpPortNum 1.3.6.1.4.1.171.14.15.1.3.1.1.2
In an MSTP Bridge, the Port's Port Number parameter value for the MSTI, i.e. the number of the Bridge Port for the MSTI.
Status: current Access: not-accessible
OBJECT-TYPE    
  IEEE8021BridgePortNumber  

dStpExtMstpPortRole 1.3.6.1.4.1.171.14.15.1.3.1.1.3
The MSTI's current port role as defined by application of MSTP.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER root(1), alternate(2), designated(3), backup(4), master(5)  

dStpExtMIBCompliances 1.3.6.1.4.1.171.14.15.2.1
OBJECT IDENTIFIER    

dStpExtCompliance 1.3.6.1.4.1.171.14.15.2.1.1
The compliance statement for entities which implement the DLINKSW-STP-EXT-MIB.
Status: current Access: read-only
MODULE-COMPLIANCE    

dStpExtGroups 1.3.6.1.4.1.171.14.15.2.1.2
OBJECT IDENTIFIER    

dStpExtBasicGroup 1.3.6.1.4.1.171.14.15.2.1.2.1
This group contains the collection of objects related to STP/RSTP configuration/status which cannot be covered by standard MIBs.
Status: current Access: read-only
OBJECT-GROUP    

dStpExtMstpGroup 1.3.6.1.4.1.171.14.15.2.1.2.2
This group contains the collection of objects related to MSTP configuration/status which cannot be covered by standard MIBs.
Status: current Access: read-only
OBJECT-GROUP    

dStpExtServiceProviderCfgGroup 1.3.6.1.4.1.171.14.15.2.1.2.3
A collection of objects configures STP in service provider site.
Status: current Access: read-only
OBJECT-GROUP