DES3810-28-L2MGMT-MIB

File: DES3810-28-L2MGMT-MIB.mib (83608 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC DLINK-ID-REC-MIB
SW3810PRIMGMT-MIB PORT-SECURITY-MIB

Imported symbols

IpAddress TimeTicks Integer32
Unsigned32 MODULE-IDENTITY OBJECT-TYPE
DisplayString RowStatus TruthValue
AgentNotifyLevel des3810-28 swPortSecPortIndex

Defined Types

MacAddress  
OCTET STRING Size(6)    

VlanId  
INTEGER 1..4094    

PortList  
OCTET STRING Size(0..127)    

Ipv6Address  
This data type is used to model IPv6 addresses. This is a binary string of 16 octets in network byte-order.
TEXTUAL-CONVENTION    
  OCTET STRING Size(16)  

SwL2DevCtrlCFMPortEntry  
SEQUENCE    
  swL2DevCtrlCFMPortIndex INTEGER
  swL2DevCtrlCFMPortState INTEGER

SwL2VlanStaticEntry  
SEQUENCE    
  swL2VlanIndex VlanId
  swL2VLANAdvertisement INTEGER

SwL2VlanPortInfoEntry  
SEQUENCE    
  swL2VlanPortInfoPortIndex INTEGER
  swL2VlanPortInfoVid INTEGER
  swL2VlanPortInfoPortRole INTEGER

SwL2PortInfoEntry  
SEQUENCE    
  swL2PortInfoPortIndex INTEGER
  swL2PortInfoMediumType INTEGER
  swL2PortInfoUnitID INTEGER
  swL2PortInfoType INTEGER
  swL2PortInfoLinkStatus INTEGER
  swL2PortInfoNwayStatus INTEGER
  swL2PortInfoErrorDisabled INTEGER

SwL2PortCtrlEntry  
SEQUENCE    
  swL2PortCtrlPortIndex INTEGER
  swL2PortCtrlMediumType INTEGER
  swL2PortCtrlUnitIndex INTEGER
  swL2PortCtrlAdminState INTEGER
  swL2PortCtrlNwayState INTEGER
  swL2PortCtrlFlowCtrlState INTEGER
  swL2PortCtrlLearningState INTEGER
  swL2PortCtrlMACNotifyState INTEGER
  swL2PortCtrlMDIXState INTEGER

SwL2PortCounterCtrlEntry  
SEQUENCE    
  swL2PortCounterCtrlPortIndex INTEGER
  swL2PortCounterClearCtrl INTEGER

SwL2PortErrEntry  
SEQUENCE    
  swL2PortErrPortIndex INTEGER
  swL2PortErrPortState INTEGER
  swL2PortErrPortConnStatus INTEGER
  swL2PortErrPortReason INTEGER

SwL2TrunkCtrlEntry  
SEQUENCE    
  swL2TrunkIndex INTEGER
  swL2TrunkMasterPort INTEGER
  swL2TrunkMember PortList
  swL2TrunkFloodingPort INTEGER
  swL2TrunkType INTEGER
  swL2TrunkState RowStatus

SwL2TrunkLACPPortEntry  
SEQUENCE    
  swL2TrunkLACPPortIndex INTEGER
  swL2TrunkLACPPortState INTEGER

SwL2TrunkVLANEntry  
SEQUENCE    
  swL2TrunkVLANPort INTEGER
  swL2TrunkVLANState INTEGER

SwL2TrafficSegEntry  
SEQUENCE    
  swL2TrafficSegPort INTEGER
  swL2TrafficSegForwardPorts PortList

SwL2MulticastFilterModeVlanEntry  
SEQUENCE    
  swL2MulticastFilterVid INTEGER
  swL2MulticastFilterVlanMode INTEGER

SwL2DhcpLocalRelayVLANEntry  
SEQUENCE    
  swL2DhcpLocalRelayVLANID INTEGER
  swL2DhcpLocalRelayVLANState INTEGER

Defined Values

swL2MgmtMIB 1.3.6.1.4.1.171.11.114.1.1.2
The Structure of Layer 2 Network Management Information.
MODULE-IDENTITY    

swL2DevMgmt 1.3.6.1.4.1.171.11.114.1.1.2.1
OBJECT IDENTIFIER    

swL2VLANMgmt 1.3.6.1.4.1.171.11.114.1.1.2.2
OBJECT IDENTIFIER    

swL2PortMgmt 1.3.6.1.4.1.171.11.114.1.1.2.3
OBJECT IDENTIFIER    

swL2DhcpRelayMgmt 1.3.6.1.4.1.171.11.114.1.1.2.8
OBJECT IDENTIFIER    

swL2TrunkMgmt 1.3.6.1.4.1.171.11.114.1.1.2.9
OBJECT IDENTIFIER    

swL2MirrorMgmt 1.3.6.1.4.1.171.11.114.1.1.2.10
OBJECT IDENTIFIER    

swL2TrafficSegMgmt 1.3.6.1.4.1.171.11.114.1.1.2.14
OBJECT IDENTIFIER    

swL2MulticastFilterMode 1.3.6.1.4.1.171.11.114.1.1.2.17
OBJECT IDENTIFIER    

swL2DhcpLocalRelayMgmt 1.3.6.1.4.1.171.11.114.1.1.2.24
OBJECT IDENTIFIER    

swL2MgmtMIBTraps 1.3.6.1.4.1.171.11.114.1.1.2.100
OBJECT IDENTIFIER    

swL2DevInfo 1.3.6.1.4.1.171.11.114.1.1.2.1.1
OBJECT IDENTIFIER    

swDevInfoTotalNumOfPort 1.3.6.1.4.1.171.11.114.1.1.2.1.1.1
The number of ports within this switch. This value is the sum of the ports within this switch.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

swDevInfoNumOfPortInUse 1.3.6.1.4.1.171.11.114.1.1.2.1.1.2
The number of ports in this switch connected to the segment or the end stations.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

swDevInfoFrontPanelLedStatus 1.3.6.1.4.1.171.11.114.1.1.2.1.1.4
This object is a set of system LED indications. The first six octets are defined as system LED. The first two octets are currently unused and must be set to zero. The third octet indicates the power LED. The fourth octet indicates the console LED. The fifth LED is RPS (Redundancy Power Supply) LED. The sixth LED is Master(Stacking Master Device) LED. For the byte range form 7 to 8, it reflect the MGMT port. Every two bytes are presented to a port. For the byte range from 9 to 56, it reflect the 1~24FE ports. Every two bytes are presented to a port. For the byte range from 57 to 64, it reflect the 25~26GE Combol ports. Every four bytes are presented to a port. The byte range from 57 to 60, it reflect copper ports. The byte range from 61 to 64, it reflect fiber ports. For the byte range from 65 to 72, it reflect the 27~28GE Combol ports. Every four bytes are presented to a port. The byte range from 65 to 68, it reflect copper ports. The byte range from 69 to 72, it reflect fiber ports. Every two bytes are presented to a port. The first byte is presented as the Link/Activity LED. The second byte is presented as the Speed LED. Power LED: 01 = fail/error/non existence 02 = work normal Console LED: 01 = Console LED OFF 02 = Console LED ON RPS LED: 01 = RPS LED OFF 02 = RPS LED ON Master LED: 01 = Master LED OFF 02 = Master LED ON Link/Activity LED : The most significant bit is used for blink/solid: 8 = The LED blinks. The second most significant bit is used for link status: 1 = link fail. 2 = link pass. Speed LED : 01 = 10Mbps. 02 = 100Mbps. 03 = 1000Mbps. The remaining bytes are currently unused and must be 0.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..127)  

swL2DevCtrl 1.3.6.1.4.1.171.11.114.1.1.2.1.2
OBJECT IDENTIFIER    

swL2DevCtrlSnmpTrapState 1.3.6.1.4.1.171.11.114.1.1.2.1.2.5
This object controls the SNMP trap status.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

swL2DevCtrlCleanAllStatisticCounter 1.3.6.1.4.1.171.11.114.1.1.2.1.2.6
When the object is set to active, all statistical counters will be cleared. If set to normal, no action.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER normal(1), active(2)  

swL2DevCtrlVlanIdOfFDBTbl 1.3.6.1.4.1.171.11.114.1.1.2.1.2.7
Indicates the VLAN ID to which the Dot1dTpFdbTable belongs; The default value is DEFAULT-VLAN-ID of the system.
Status: current Access: read-write
OBJECT-TYPE    
  VlanId  

swL2MACNotifyState 1.3.6.1.4.1.171.11.114.1.1.2.1.2.8
This object can enable or disable MAC Notification.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER other(1), disabled(2), enabled(3)  

swL2MACNotifyHistorySize 1.3.6.1.4.1.171.11.114.1.1.2.1.2.9
This object indicates the history size of MAC addresses in the MAC Address table. The default value is 1 .
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..500  

swL2MACNotifyInterval 1.3.6.1.4.1.171.11.114.1.1.2.1.2.10
This object indicates the time interval, in seconds, which will trigger MAC notification messages.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..2147483647  

swL2DevCtrlTelnet 1.3.6.1.4.1.171.11.114.1.1.2.1.2.14
OBJECT IDENTIFIER    

swL2DevCtrlTelnetState 1.3.6.1.4.1.171.11.114.1.1.2.1.2.14.1
This object controls the Telnet status.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER other(1), disabled(2), enabled(3)  

swL2DevCtrlTelnetTcpPort 1.3.6.1.4.1.171.11.114.1.1.2.1.2.14.2
This object designates TCP ports. When Telnet is disabled, this object is not accessible.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

swL2DevCtrlManagementVlanId 1.3.6.1.4.1.171.11.114.1.1.2.1.2.16
This object controls which previously created VLANs are included in the System IP Interface.
Status: current Access: read-write
OBJECT-TYPE    
  VlanId  

swL2DevCtrlWeb 1.3.6.1.4.1.171.11.114.1.1.2.1.2.17
OBJECT IDENTIFIER    

swL2DevCtrlWebState 1.3.6.1.4.1.171.11.114.1.1.2.1.2.17.1
This object controls the Web status.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

swL2DevCtrlWebTcpPort 1.3.6.1.4.1.171.11.114.1.1.2.1.2.17.2
This object designates TCP ports. When Web is disabled, this object is not accessible.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..65535  

swL2DevCtrlLLDPState 1.3.6.1.4.1.171.11.114.1.1.2.1.2.18
Specifies the state of the LLDP function. When this function is enabled, the switch can start to transmit LLDP packets and receive and process the LLDP packets. The specific function of each port will depend on the per port LLDP setting. For the advertisement of LLDP packets, the switch announces the information to its neighbor through ports. For the receiving of LLDP packets, the switch will learn the information from the LLDP packets advertised from the neighbor in the neighbor table.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

swL2DevCtrlLLDPForwardMessageState 1.3.6.1.4.1.171.11.114.1.1.2.1.2.19
When lldp is disabled and lldp forward-message is enabled, the received LLDP Data Unit packets will be forwarded.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

swL2DevCtrlIpAutoconfig 1.3.6.1.4.1.171.11.114.1.1.2.1.2.20
This object controls the IP auto configuration state.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

swL2DevCtrlCFM 1.3.6.1.4.1.171.11.114.1.1.2.1.2.21
OBJECT IDENTIFIER    

swL2DevCtrlCFMState 1.3.6.1.4.1.171.11.114.1.1.2.1.2.21.1
This object indicates the CFM global state.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

swL2DevCtrlCFMPortTable 1.3.6.1.4.1.171.11.114.1.1.2.1.2.21.2
A table containing CFM state of speicified ports.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SwL2DevCtrlCFMPortEntry

swL2DevCtrlCFMPortEntry 1.3.6.1.4.1.171.11.114.1.1.2.1.2.21.2.1
The entry of CFM state on speicified ports.
Status: current Access: not-accessible
OBJECT-TYPE    
  SwL2DevCtrlCFMPortEntry  

swL2DevCtrlCFMPortIndex 1.3.6.1.4.1.171.11.114.1.1.2.1.2.21.2.1.1
This object indicates the port-num.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER  

swL2DevCtrlCFMPortState 1.3.6.1.4.1.171.11.114.1.1.2.1.2.21.2.1.2
This object indicates the CFM state on per-port.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

swL2DevCtrlVLANTrunkState 1.3.6.1.4.1.171.11.114.1.1.2.1.2.22
This indicates the global state of the VLAN trunking feature of the device.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

swL2DevAlarm 1.3.6.1.4.1.171.11.114.1.1.2.1.3
OBJECT IDENTIFIER    

swL2DevAlarmNewRoot 1.3.6.1.4.1.171.11.114.1.1.2.1.3.1
When the device has become the new root of the Spanning Tree, this object decides whether to send a new root trap.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER other(1), disabled(2), enabled(3)  

swL2DevAlarmTopologyChange 1.3.6.1.4.1.171.11.114.1.1.2.1.3.2
This object determines whether or not to send a trap message when the switch topology changes. If the object is enabled(3), the topologyChange trap is sent by the device when any of its configured ports transitions from the Learning state to the Forwarding state, or from the Forwarding state to the Blocking state. For the same port transition, the device does not send the trap if this object value is disabled or other.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER other(1), disabled(2), enabled(3)  

swL2DevAlarmLinkChange 1.3.6.1.4.1.171.11.114.1.1.2.1.3.3
This object determines whether or not to send a trap message when the link was changed. If the object is enabled(3), the Link Change trap is sent by the device when any of its ports link change. The device does not send the trap if this object value is disabled or other.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER other(1), disabled(2), enabled(3)  

swL2VlanStaticTable 1.3.6.1.4.1.171.11.114.1.1.2.2.1
A table containing static configuration information for each VLAN configured into the device by (local or network) management. All entries are permanent and will be restored after the device is reset.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SwL2VlanStaticEntry

swL2VlanStaticEntry 1.3.6.1.4.1.171.11.114.1.1.2.2.1.1
Static information for a VLAN configured into the device by (local or network) management.
Status: current Access: not-accessible
OBJECT-TYPE    
  SwL2VlanStaticEntry  

swL2VlanIndex 1.3.6.1.4.1.171.11.114.1.1.2.2.1.1.1
The VLAN-ID or other identifier referring to this VLAN.
Status: current Access: not-accessible
OBJECT-TYPE    
  VlanId  

swL2VLANAdvertisement 1.3.6.1.4.1.171.11.114.1.1.2.2.1.1.2
This object indicates if the advertisement is active or not.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

swL2PVIDAutoAssignmentState 1.3.6.1.4.1.171.11.114.1.1.2.2.2
This object controls the PVID auto assigment state. If 'Auto-assign PVID' is disabled, PVID can only be changed by PVID configuration (user changes explicitly). The VLAN configuration will not automatically change the PVID. If 'Auto-assign PVID' is enabled, the PVID will be changed by PVID or VLAN configuration. When a user configures a port to VLAN X's untagged membership, this port's PVID will be updated with VLAN X. Using the VLAN list command, PVID is updated as the last item of the VLAN list. When a user removes a port from the untagged membership of the PVID's VLAN, the port's PVID will be assigned 'default VLAN'.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

swL2VlanPortInfoTable 1.3.6.1.4.1.171.11.114.1.1.2.2.3
A table containing vlan and port role information of each port.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SwL2VlanPortInfoEntry

swL2VlanPortInfoEntry 1.3.6.1.4.1.171.11.114.1.1.2.2.3.1
The table entry of vlan port information.
Status: current Access: not-accessible
OBJECT-TYPE    
  SwL2VlanPortInfoEntry  

swL2VlanPortInfoPortIndex 1.3.6.1.4.1.171.11.114.1.1.2.2.3.1.1
The port index.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

swL2VlanPortInfoVid 1.3.6.1.4.1.171.11.114.1.1.2.2.3.1.2
The VLAN-ID assigned to a special port
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

swL2VlanPortInfoPortRole 1.3.6.1.4.1.171.11.114.1.1.2.2.3.1.3
The port role of a special port.when none,it means this port is not belong to the vlan.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(1), untagged(2), tagged(3), dynamic(4), forbidden(5)  

swL2NniGvrpBpduAddress 1.3.6.1.4.1.171.11.114.1.1.2.2.7
Specifies the GVRP's BPDU MAC address of NNI port In Q-in-Q status.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER dot1d(1), dot1ad(2)  

swL2PortInfoTable 1.3.6.1.4.1.171.11.114.1.1.2.3.1
A table that contains information about every port.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SwL2PortInfoEntry

swL2PortInfoEntry 1.3.6.1.4.1.171.11.114.1.1.2.3.1.1
A list of information for each port of the device.
Status: current Access: not-accessible
OBJECT-TYPE    
  SwL2PortInfoEntry  

swL2PortInfoPortIndex 1.3.6.1.4.1.171.11.114.1.1.2.3.1.1.1
This object indicates the module's port number.(1..Max port number in the module)
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

swL2PortInfoMediumType 1.3.6.1.4.1.171.11.114.1.1.2.3.1.1.2
Indicates medium type of the port number.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER copper(1), fiber(2)  

swL2PortInfoUnitID 1.3.6.1.4.1.171.11.114.1.1.2.3.1.1.3
Indicates ID of the unit in the system
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

swL2PortInfoType 1.3.6.1.4.1.171.11.114.1.1.2.3.1.1.4
This object indicates the connector type of this port.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER portType-none(0), portType-100Base-T(2), portType-100Base-X(3), portType-1000Base-T(4), portType-1000Base-X(5), portType-10GBase-R(6), portType-10GBase-CX4(7), portType-SIO(8), portType-module-empty(9), portType-user-last(10)  

swL2PortInfoLinkStatus 1.3.6.1.4.1.171.11.114.1.1.2.3.1.1.5
This object indicates the port link status.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER other(1), link-pass(2), link-fail(3)  

swL2PortInfoNwayStatus 1.3.6.1.4.1.171.11.114.1.1.2.3.1.1.6
This object indicates the port speed and duplex mode.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER link-down(0), full-10Mbps-8023x(1), full-10Mbps-none(2), half-10Mbps-backp(3), half-10Mbps-none(4), full-100Mbps-8023x(5), full-100Mbps-none(6), half-100Mbps-backp(7), half-100Mbps-none(8), full-1Gigabps-8023x(9), full-1Gigabps-none(10), half-1Gigabps-backp(11), half-1Gigabps-none(12), full-10Gigabps-8023x(13), full-10Gigabps-none(14), half-10Gigabps-8023x(15), half-10Gigabps-none(16), empty(17), err-disabled(18)  

swL2PortInfoErrorDisabled 1.3.6.1.4.1.171.11.114.1.1.2.3.1.1.8
This object indicates the blocking type of this port.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(0), storm(1), unknow(3), ctp-lbd(4), ddm(5), bpdu-protection(6), power-saving(7)  

swL2PortCtrlTable 1.3.6.1.4.1.171.11.114.1.1.2.3.2
A table that contains control information about every port.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SwL2PortCtrlEntry

swL2PortCtrlEntry 1.3.6.1.4.1.171.11.114.1.1.2.3.2.1
A list of control information for each port of the device.
Status: current Access: not-accessible
OBJECT-TYPE    
  SwL2PortCtrlEntry  

swL2PortCtrlPortIndex 1.3.6.1.4.1.171.11.114.1.1.2.3.2.1.1
This object indicates the module's port number.(1..Max port number in the module)
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

swL2PortCtrlMediumType 1.3.6.1.4.1.171.11.114.1.1.2.3.2.1.2
Indicates medium type of the port number.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER copper(1), fiber(2)  

swL2PortCtrlUnitIndex 1.3.6.1.4.1.171.11.114.1.1.2.3.2.1.3
Indicates ID of the unit in the device
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

swL2PortCtrlAdminState 1.3.6.1.4.1.171.11.114.1.1.2.3.2.1.4
This object decides if the port is enabled or disabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER other(1), disabled(2), enabled(3)  

swL2PortCtrlNwayState 1.3.6.1.4.1.171.11.114.1.1.2.3.2.1.5
Chose the port speed, duplex mode, and N-Way function mode.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER other(1), nway-enabled(2), nway-disabled-10Mbps-Half(3), nway-disabled-10Mbps-Full(4), nway-disabled-100Mbps-Half(5), nway-disabled-100Mbps-Full(6), nway-disabled-1Gigabps-Half(7), nway-disabled-1Gigabps-Full(8), nway-disabled-1Gigabps-Full-master(9), nway-disabled-1Gigabps-Full-slave(10)  

swL2PortCtrlFlowCtrlState 1.3.6.1.4.1.171.11.114.1.1.2.3.2.1.6
The flow control mechanism is different between full duplex mode and half duplex mode. For half duplex mode, the jamming signal is asserted. For full duplex mode, IEEE 802.3x flow control function sends PAUSE frames and receives PAUSE frames.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER other(1), disabled(2), enabled(3)  

swL2PortCtrlLearningState 1.3.6.1.4.1.171.11.114.1.1.2.3.2.1.7
This object decides if the port is locked or not.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER other(1), disabled(2), enabled(3)  

swL2PortCtrlMACNotifyState 1.3.6.1.4.1.171.11.114.1.1.2.3.2.1.8
This object sets each port's MAC notification state.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER other(1), disabled(2), enabled(3)  

swL2PortCtrlMDIXState 1.3.6.1.4.1.171.11.114.1.1.2.3.2.1.10
This object configures the MDIX setting of the port.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER auto(1), normal(2), cross(3)  

swL2PortCtrlJumboFrame 1.3.6.1.4.1.171.11.114.1.1.2.3.3
This object configures the switch's jumbo frame settings.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER other(1), disabled(2), enabled(3)  

swL2PortCtrlJumboFrameMaxSize 1.3.6.1.4.1.171.11.114.1.1.2.3.4
This object describes how many bytes the max jumbo frame is.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER  

swL2PortCounterCtrlTable 1.3.6.1.4.1.171.11.114.1.1.2.3.6
A table that used to clear counter information about every port.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SwL2PortCounterCtrlEntry

swL2PortCounterCtrlEntry 1.3.6.1.4.1.171.11.114.1.1.2.3.6.1
A list of entry used to clear counter information for each port of the device.
Status: current Access: not-accessible
OBJECT-TYPE    
  SwL2PortCounterCtrlEntry  

swL2PortCounterCtrlPortIndex 1.3.6.1.4.1.171.11.114.1.1.2.3.6.1.1
This object indicates the module's port number.(1..Max port number in the module)
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

swL2PortCounterClearCtrl 1.3.6.1.4.1.171.11.114.1.1.2.3.6.1.2
This object indicates if to clear the counters for each port of the device or not.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER other(1), start(2)  

swL2PortErrTable 1.3.6.1.4.1.171.11.114.1.1.2.3.7
A table that contains error information for each port.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SwL2PortErrEntry

swL2PortErrEntry 1.3.6.1.4.1.171.11.114.1.1.2.3.7.1
A list of information regarding port errors on the device.
Status: current Access: not-accessible
OBJECT-TYPE    
  SwL2PortErrEntry  

swL2PortErrPortIndex 1.3.6.1.4.1.171.11.114.1.1.2.3.7.1.1
This object indicates the module's port number.(1..Max port number in the module).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

swL2PortErrPortState 1.3.6.1.4.1.171.11.114.1.1.2.3.7.1.2
This object indicates the port state is enabled or disabled.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

swL2PortErrPortConnStatus 1.3.6.1.4.1.171.11.114.1.1.2.3.7.1.3
This object indicates whether the PortStatus is err-disabled or not.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER other(1), err-disabled(2)  

swL2PortErrPortReason 1.3.6.1.4.1.171.11.114.1.1.2.3.7.1.4
This object describes if the reason for the port error is STP LBD or Storm control.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER storm-control(2), ctp-lbd(3), ddm(4), bpdu-protection(5), power-saving(7)  

swL2TrunkMaxSupportedEntries 1.3.6.1.4.1.171.11.114.1.1.2.9.1
Maximum number of entries in the trunk configuration table (swL2TrunkCtrlTable).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

swL2TrunkCurrentNumEntries 1.3.6.1.4.1.171.11.114.1.1.2.9.2
Current active number of entries in the trunk configuration table.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

swL2TrunkCtrlTable 1.3.6.1.4.1.171.11.114.1.1.2.9.3
This table specifies which ports group a set of ports(up to 8) into a single logical link.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SwL2TrunkCtrlEntry

swL2TrunkCtrlEntry 1.3.6.1.4.1.171.11.114.1.1.2.9.3.1
A list of information that specifies which ports group a set of ports(up to 8) into a single logical link.
Status: current Access: not-accessible
OBJECT-TYPE    
  SwL2TrunkCtrlEntry  

swL2TrunkIndex 1.3.6.1.4.1.171.11.114.1.1.2.9.3.1.1
The index number of the logical port trunk group. The trunk group number depends on the existence of unit and module.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

swL2TrunkMasterPort 1.3.6.1.4.1.171.11.114.1.1.2.9.3.1.3
The object indicates the master port number of the port trunk entry. When using Port Trunk, you cannot configure the other ports of the group except the master port. Their configuration must be same as the master port (e.g. speed, duplex, enabled/disabled, flow control, and so on).
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER 1..65535  

swL2TrunkMember 1.3.6.1.4.1.171.11.114.1.1.2.9.3.1.4
Indicates the number of ports included in this Trunk group. The trunk port number depends on the existence of the module. The maximum number of ports is 8 for one trunk group.
Status: current Access: read-create
OBJECT-TYPE    
  PortList  

swL2TrunkFloodingPort 1.3.6.1.4.1.171.11.114.1.1.2.9.3.1.5
The object indicates the flooding port number of the port trunk entry. The first port of the Trunk group is implicitly configured to be the flooding port.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

swL2TrunkType 1.3.6.1.4.1.171.11.114.1.1.2.9.3.1.6
This object indicates the type of trunk group. static : is static trunk group lacp : is LACP trunk group .
Status: current Access: read-create
OBJECT-TYPE    
  INTEGER other(1), static(2), lacp(3)  

swL2TrunkState 1.3.6.1.4.1.171.11.114.1.1.2.9.3.1.7
This object indicates the status of this entry.
Status: current Access: read-create
OBJECT-TYPE    
  RowStatus  

swL2TrunkAlgorithm 1.3.6.1.4.1.171.11.114.1.1.2.9.4
This object configures to part of the packet examined by the switch when selecting the egress port for transmitting load-sharing data.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER other(1), mac-source(2), mac-destination(3), mac-source-dest(4), ip-source(5), ip-destination(6), ip-source-dest(7), l4-source(8), l4-destination(9), l4-source-dest(10)  

swL2TrunkLACPPortTable 1.3.6.1.4.1.171.11.114.1.1.2.9.5
This table specifies which ports group a set of ports(up to 8) into a single logical link.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SwL2TrunkLACPPortEntry

swL2TrunkLACPPortEntry 1.3.6.1.4.1.171.11.114.1.1.2.9.5.1
A list of information specifies which ports group a set of ports(up to 8) into a single logical link.
Status: current Access: not-accessible
OBJECT-TYPE    
  SwL2TrunkLACPPortEntry  

swL2TrunkLACPPortIndex 1.3.6.1.4.1.171.11.114.1.1.2.9.5.1.1
The index of logical port LACP.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

swL2TrunkLACPPortState 1.3.6.1.4.1.171.11.114.1.1.2.9.5.1.2
The state of logical port LACP.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER active(1), passive(2)  

swL2TrunkVLANTable 1.3.6.1.4.1.171.11.114.1.1.2.9.6
This table is used to manage the VLAN trunking feature of the device.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SwL2TrunkVLANEntry

swL2TrunkVLANEntry 1.3.6.1.4.1.171.11.114.1.1.2.9.6.1
This object is used to configure the VLAN trunking settings for each port.
Status: current Access: not-accessible
OBJECT-TYPE    
  SwL2TrunkVLANEntry  

swL2TrunkVLANPort 1.3.6.1.4.1.171.11.114.1.1.2.9.6.1.1
This object indicates the port being configured.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

swL2TrunkVLANState 1.3.6.1.4.1.171.11.114.1.1.2.9.6.1.2
The state of the logical port LACP.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(1), disabled(2)  

swL2MirrorLogicTargetPort 1.3.6.1.4.1.171.11.114.1.1.2.10.1
This object indicates which switch port will sniff another port. A trunk port member cannot be configured as a target snooping port. The port number is the sequential (logical) number which is also applied to the bridge MIB, etc.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

swL2MirrorPortSourceIngress 1.3.6.1.4.1.171.11.114.1.1.2.10.2
This represents the port where ingress packets will be sniffed.
Status: current Access: read-write
OBJECT-TYPE    
  PortList  

swL2MirrorPortSourceEgress 1.3.6.1.4.1.171.11.114.1.1.2.10.3
This represents the port where egress packets will be sniffed.
Status: current Access: read-write
OBJECT-TYPE    
  PortList  

swL2MirrorPortState 1.3.6.1.4.1.171.11.114.1.1.2.10.4
This object indicates the port mirroring state. other(1) - this entry is currently in use but the conditions under which it will remain so are different from each of the following values. disabled(2) - After writing this value to the object, the corresponding entry will be removed from the table. enabled(3) - This entry resides in the table.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER other(1), disabled(2), enabled(3)  

swL2TrafficSegTable 1.3.6.1.4.1.171.11.114.1.1.2.14.1
This table specifies that the port can just forward traffic to the specific port list.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SwL2TrafficSegEntry

swL2TrafficSegEntry 1.3.6.1.4.1.171.11.114.1.1.2.14.1.1
A list of information which specifies the port with its traffic forwarding list.
Status: current Access: not-accessible
OBJECT-TYPE    
  SwL2TrafficSegEntry  

swL2TrafficSegPort 1.3.6.1.4.1.171.11.114.1.1.2.14.1.1.1
The port number of the logical port.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

swL2TrafficSegForwardPorts 1.3.6.1.4.1.171.11.114.1.1.2.14.1.1.2
The port list to which the specific port can forward traffic.
Status: current Access: read-write
OBJECT-TYPE    
  PortList  

swL2MulticastFilterModeVlanTable 1.3.6.1.4.1.171.11.114.1.1.2.17.1
A table that contains information about VLAN multicast filter mode.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SwL2MulticastFilterModeVlanEntry

swL2MulticastFilterModeVlanEntry 1.3.6.1.4.1.171.11.114.1.1.2.17.1.1
A list of multicast filter mode information for each VLAN.
Status: current Access: not-accessible
OBJECT-TYPE    
  SwL2MulticastFilterModeVlanEntry  

swL2MulticastFilterVid 1.3.6.1.4.1.171.11.114.1.1.2.17.1.1.1
Indicates VID for each VLAN.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

swL2MulticastFilterVlanMode 1.3.6.1.4.1.171.11.114.1.1.2.17.1.1.2
Specifies multicast filter mode for each VLAN.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER forward-unregistered-groups(2), filter-unregistered-groups(3)  

swL2DhcpLocalRelayState 1.3.6.1.4.1.171.11.114.1.1.2.24.1
This object indicates the status of the DHCP local relay function of the switch.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER other(1), disabled(2), enabled(3)  

swL2DhcpLocalRelayVLANTable 1.3.6.1.4.1.171.11.114.1.1.2.24.2
This table is used to manage the DHCP local relay status for each VLAN.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    SwL2DhcpLocalRelayVLANEntry

swL2DhcpLocalRelayVLANEntry 1.3.6.1.4.1.171.11.114.1.1.2.24.2.1
This object lists the current VLANs in the switch and their corresponding DHCP local relay status.
Status: current Access: not-accessible
OBJECT-TYPE    
  SwL2DhcpLocalRelayVLANEntry  

swL2DhcpLocalRelayVLANID 1.3.6.1.4.1.171.11.114.1.1.2.24.2.1.1
This object shows the VIDs of the current VLANS in the switch.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 1..4094  

swL2DhcpLocalRelayVLANState 1.3.6.1.4.1.171.11.114.1.1.2.24.2.1.2
This object indicates the status of the DHCP relay function of the VLAN.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER other(1), disabled(2), enabled(3)  

swL2Notify 1.3.6.1.4.1.171.11.114.1.1.2.100.1
OBJECT IDENTIFIER    

swL2NotifyMgmt 1.3.6.1.4.1.171.11.114.1.1.2.100.1.1
OBJECT IDENTIFIER    

swL2NotifyPrefix 1.3.6.1.4.1.171.11.114.1.1.2.100.1.2
OBJECT IDENTIFIER    

swL2NotifFirmware 1.3.6.1.4.1.171.11.114.1.1.2.100.1.2.0
OBJECT IDENTIFIER    

swL2macNotification 1.3.6.1.4.1.171.11.114.1.1.2.100.1.2.0.1
This trap indicates the MAC addresses variation in address table .
Status: current Access: read-write
NOTIFICATION-TYPE    

swL2PortSecurityViolationTrap 1.3.6.1.4.1.171.11.114.1.1.2.100.1.2.0.2
When the port-security trap is enabled, new MAC addresses that violate the pre-defined port security configuration will trigger trap messages to be sent out.
Status: current Access: read-write
NOTIFICATION-TYPE    

swl2NotificationBidings 1.3.6.1.4.1.171.11.114.1.1.2.100.1.2.1
OBJECT IDENTIFIER    

swL2macNotifyInfo 1.3.6.1.4.1.171.11.114.1.1.2.100.1.2.1.1
This object indicates the last time reboot information.
Status: current Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(0..1024)  

swL2PortSecurityViolationMac 1.3.6.1.4.1.171.11.114.1.1.2.100.1.2.1.2
This object indicates the MAC address that violates the port security configuration.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  MacAddress