DELL-RAC-MIB
File:
DELL-RAC-MIB.mib (161404 bytes)
Imported modules
Imported symbols
Defined Types
DellRacType |
|
INTEGER |
other(1), unknown(2), dracIII(3), era(4), drac4(5), drac5(6), drac5MC(7), cmc(8), idrac(9), vrtxCMC(18), fx2CMC(19) |
|
|
DellStatus |
|
INTEGER |
other(1), unknown(2), ok(3), nonCritical(4), critical(5), nonRecoverable(6) |
|
|
DrsCMCPowerTableEntry |
|
SEQUENCE |
|
|
|
|
drsChassisIndex |
DellCMCPowerIndexRange |
|
|
drsPotentialPower |
DellPowerReading |
|
|
drsIdlePower |
DellPowerReading |
|
|
drsMaxPowerSpecification |
DellPowerReading |
|
|
drsPowerSurplus |
DellPowerReading |
|
|
drsKWhCumulative |
DellPowerReading |
|
|
drsKWhCumulativeTime |
DellTimestamp |
|
|
drsWattsPeakUsage |
DellPowerReading |
|
|
drsWattsPeakTime |
DellTimestamp |
|
|
drsWattsMinUsage |
DellPowerReading |
|
|
drsWattsMinTime |
DellTimestamp |
|
|
drsWattsResetTime |
DellTimestamp |
|
|
drsWattsReading |
DellPowerReading |
|
|
drsAmpsReading |
DellPowerReading |
|
DrsCMCPSUTableEntry |
|
SEQUENCE |
|
|
|
|
drsPSUChassisIndex |
DellCMCPowerIndexRange |
|
|
drsPSUIndex |
DellCMCPSUIndexRange |
|
|
drsPSULocation |
DellString |
|
|
drsPSUMonitoringCapable |
DellCMCPSUCapable |
|
|
drsPSUVoltsReading |
DellPowerReading |
|
|
drsPSUAmpsReading |
DellPowerReading |
|
|
drsPSUWattsReading |
DellPowerReading |
|
DrsCMCServerTableEntry |
|
SEQUENCE |
|
|
|
|
drsServerIndex |
DellCMCServerIndexRange |
|
|
drsServerMonitoringCapable |
DellCMCServerCapable |
|
|
drsServerServiceTag |
DellString |
|
|
drsServerSlotName |
DellString |
|
|
drsServerSlotNumber |
DellString |
|
|
drsServerNodeID |
DellString |
|
Defined Values
dell |
1.3.6.1.4.1.674 |
OBJECT IDENTIFIER |
|
|
|
server3 |
1.3.6.1.4.1.674.10892 |
OBJECT IDENTIFIER |
|
|
|
drsProductName |
1.3.6.1.4.1.674.10892.2.1.1.1 |
0001.0001.0001 This attribute defines the product name of a chassis management controller. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DellString |
|
|
drsProductShortName |
1.3.6.1.4.1.674.10892.2.1.1.2 |
0001.0001.0002 This attribute defines the short product name of a chassis management controller. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DellString |
|
|
drsProductDescription |
1.3.6.1.4.1.674.10892.2.1.1.3 |
0001.0001.0003 This attribute defines the product description of a chassis management controller. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DellString |
|
|
drsProductManufacturer |
1.3.6.1.4.1.674.10892.2.1.1.4 |
0001.0001.0004 This attribute defines the product manufacturer of a chassis management controller. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DellString |
|
|
drsProductVersion |
1.3.6.1.4.1.674.10892.2.1.1.5 |
0001.0001.0005 This attribute defines the product version of a chassis management controller. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DellString |
|
|
drsChassisServiceTag |
1.3.6.1.4.1.674.10892.2.1.1.6 |
0001.0001.0007 This attribute defines the Service Tag of the chassis. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DellString |
|
|
drsProductURL |
1.3.6.1.4.1.674.10892.2.1.1.7 |
0001.0001.0006 This attribute defines the out-of-band UI URL of a chassis management controller. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DellString |
|
|
drsProductChassisAssetTag |
1.3.6.1.4.1.674.10892.2.1.1.8 |
0001.0001.0008 This attribute defines the Asset Tag of the chassis. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DellString |
|
|
drsProductChassisLocation |
1.3.6.1.4.1.674.10892.2.1.1.9 |
0001.0001.0009 This attribute defines the location of the chassis. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DellString |
|
|
drsProductChassisName |
1.3.6.1.4.1.674.10892.2.1.1.10 |
0001.0001.0010 This attribute defines the name of the chassis. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DellString |
|
|
drsProductSystemAssetTag |
1.3.6.1.4.1.674.10892.2.1.1.12 |
0001.0001.0012 This attribute defines the asset tag of a system. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DellString |
|
|
drsProductSystemSlot |
1.3.6.1.4.1.674.10892.2.1.1.13 |
0001.0001.0013 This attribute defines the slot number of a CMC. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DellString |
|
|
drsProductType |
1.3.6.1.4.1.674.10892.2.1.1.14 |
0001.0001.0014 This attribute defines type of a remote access card |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DellRacType |
|
|
drsProductChassisDataCenter |
1.3.6.1.4.1.674.10892.2.1.1.15 |
0001.0001.0015 This attribute defines the Data Center locator of the chassis. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DellString |
|
|
drsProductChassisAisle |
1.3.6.1.4.1.674.10892.2.1.1.16 |
0001.0001.0016 This attribute defines the Aisle locator of the chassis. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DellString |
|
|
drsProductChassisRack |
1.3.6.1.4.1.674.10892.2.1.1.17 |
0001.0001.0017 This attribute defines the Rack locator of the chassis. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DellString |
|
|
drsProductChassisRackSlot |
1.3.6.1.4.1.674.10892.2.1.1.18 |
0001.0001.0018 This attribute defines the Rack Slot locator of the chassis. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DellString |
|
|
drsProductChassisModel |
1.3.6.1.4.1.674.10892.2.1.1.19 |
0001.0001.0019 This attribute defines the Model of the chassis. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DellString |
|
|
drsProductChassisSystemID |
1.3.6.1.4.1.674.10892.2.1.1.21 |
0001.0001.0021 This attribute defines the System ID of the chassis. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
drsProductChassisSize |
1.3.6.1.4.1.674.10892.2.1.1.22 |
0001.0001.0022 This attribute defines the size of the
chassis in rack units (U). A U is a standard unit of
measure for the height of a rack or rack-mountable component. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
drsFirmwareVersion |
1.3.6.1.4.1.674.10892.2.1.2.1 |
0001.0002.0001 This attribute defines the firmware version of chassis management controller 1. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DellString |
|
|
drsiKVMFirmwareVersion |
1.3.6.1.4.1.674.10892.2.1.2.2 |
0001.0002.0002 This attribute defines the firmware version of the iKVM. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DellString |
|
|
drsFirmwareVersion2 |
1.3.6.1.4.1.674.10892.2.1.2.3 |
0001.0002.0003 This attribute defines the firmware version of chassis management controller 2. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DellString |
|
|
drsGlobalSystemStatus |
1.3.6.1.4.1.674.10892.2.2.1 |
0002.0001.0001 This attribute defines the overall chassis status
being monitored by the chassis management card. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DellStatus |
|
|
drsGlobalCurrStatus |
1.3.6.1.4.1.674.10892.2.3.1.1 |
0003.0001.0001 This attribute defines the overall chassis status
being monitored by the chassis management card. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DellStatus |
|
|
drsIOMCurrStatus |
1.3.6.1.4.1.674.10892.2.3.1.2 |
0003.0001.0002 This attribute defines the IOM subsystem status
being monitored by the chassis management card. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DellStatus |
|
|
drsKVMCurrStatus |
1.3.6.1.4.1.674.10892.2.3.1.3 |
0003.0001.0003 This attribute defines the iKVM subsystem health status
being monitored by the chassis management card. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DellStatus |
|
|
drsRedCurrStatus |
1.3.6.1.4.1.674.10892.2.3.1.4 |
0003.0001.0004 This attribute defines the Redundancy status
being monitored by the chassis management card. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DellStatus |
|
|
drsPowerCurrStatus |
1.3.6.1.4.1.674.10892.2.3.1.5 |
0003.0001.0005 This attribute defines the power subsystem health status
being monitored by the chassis management card. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DellStatus |
|
|
drsFanCurrStatus |
1.3.6.1.4.1.674.10892.2.3.1.6 |
0003.0001.0006 This attribute defines the Fan subsystem health status
being monitored by the chassis management card. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DellStatus |
|
|
drsBladeCurrStatus |
1.3.6.1.4.1.674.10892.2.3.1.7 |
0003.0001.0007 This attribute defines the Blade subsystem health status
being monitored by the chassis management card. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DellStatus |
|
|
drsTempCurrStatus |
1.3.6.1.4.1.674.10892.2.3.1.8 |
0003.0001.0008 This attribute defines the Temp Sensor subsystem health status
being monitored by the chassis management card. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DellStatus |
|
|
drsCMCCurrStatus |
1.3.6.1.4.1.674.10892.2.3.1.9 |
0003.0001.0009 This attribute defines the CMC health status
being monitored by the chassis management card. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DellStatus |
|
|
drsCMCAmbientTemperature |
1.3.6.1.4.1.674.10892.2.3.1.11 |
0003.0001.0011 This attribute defines the ambient temperature
reading (in degrees Celsius) for the chassis management card. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DellTemperatureReading |
|
|
drsCMCProcessorTemperature |
1.3.6.1.4.1.674.10892.2.3.1.12 |
0003.0001.0012 This attribute defines the temperature reading
(in degrees Celsius) for the chassis management card processor. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DellTemperatureReading |
|
|
drsGlobalPrevStatus |
1.3.6.1.4.1.674.10892.2.3.2.1 |
0003.0002.0001 This attribute defines the previous chassis status
recorded by the chassis management card. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DellStatus |
|
|
drsIOMPrevStatus |
1.3.6.1.4.1.674.10892.2.3.2.2 |
0003.0002.0002 This attribute defines the previous IOM subsystem status
recorded by the chassis management card. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DellStatus |
|
|
drsKVMPrevStatus |
1.3.6.1.4.1.674.10892.2.3.2.3 |
0003.0002.0003 This attribute defines the previous iKVM subsystem health status
recorded by the chassis management card. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DellStatus |
|
|
drsRedPrevStatus |
1.3.6.1.4.1.674.10892.2.3.2.4 |
0003.0002.0004 This attribute defines the previous Redundancy status
recorded by the chassis management card. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DellStatus |
|
|
drsPowerPrevStatus |
1.3.6.1.4.1.674.10892.2.3.2.5 |
0003.0002.0005 This attribute defines the previous power subsystem health status
recorded by the chassis management card. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DellStatus |
|
|
drsFanPrevStatus |
1.3.6.1.4.1.674.10892.2.3.2.6 |
0003.0002.0006 This attribute defines the previous Fan health status
being monitored by the chassis management card. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DellStatus |
|
|
drsBladePrevStatus |
1.3.6.1.4.1.674.10892.2.3.2.7 |
0003.0002.0007 This attribute defines the previous Blade subsystem health status
recorded by the chassis management card. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DellStatus |
|
|
drsTempPrevStatus |
1.3.6.1.4.1.674.10892.2.3.2.8 |
0003.0001.0008 This attribute defines the Temp Sensor health status
being monitored by the chassis management card. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DellStatus |
|
|
drsCMCPrevStatus |
1.3.6.1.4.1.674.10892.2.3.2.9 |
0003.0001.0009 This attribute defines the CMC health status
being monitored by the chassis management card. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DellStatus |
|
|
drsGlobalChangeTime |
1.3.6.1.4.1.674.10892.2.3.3.1 |
0003.0003.0001 This attribute defines the timestamp of the most recent
global status change. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
TimeTicks |
|
|
drsIOMChangeTime |
1.3.6.1.4.1.674.10892.2.3.3.2 |
0003.0003.0002 This attribute defines the timestamp of the most recent
IOM status change. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
TimeTicks |
|
|
drsKVMChangeTime |
1.3.6.1.4.1.674.10892.2.3.3.3 |
0003.0003.0003 This attribute defines the timestamp of the most recent
iKVM status change. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
TimeTicks |
|
|
drsRedChangeTime |
1.3.6.1.4.1.674.10892.2.3.3.4 |
0003.0003.0004 This attribute defines the timestamp of the most recent
Redundancy status change. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
TimeTicks |
|
|
drsPowerChangeTime |
1.3.6.1.4.1.674.10892.2.3.3.5 |
0003.0003.0005 This attribute defines the timestamp of the most recent
power health status change. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
TimeTicks |
|
|
drsFanChangeTime |
1.3.6.1.4.1.674.10892.2.3.3.6 |
0003.0003.0006 This attribute defines the timestamp of the most recent
Fan health status change. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
TimeTicks |
|
|
drsBladeChangeTime |
1.3.6.1.4.1.674.10892.2.3.3.7 |
0003.0003.0007 This attribute defines the timestamp of the most recent
Blade health status change. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
TimeTicks |
|
|
drsTempChangeTime |
1.3.6.1.4.1.674.10892.2.3.3.8 |
0003.0003.0008 This attribute defines the timestamp of the most recent
Temp Sensor health status change. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
TimeTicks |
|
|
drsCMCChangeTime |
1.3.6.1.4.1.674.10892.2.3.3.9 |
0003.0003.0009 This attribute defines the timestamp of the most recent
CMC health status change. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
TimeTicks |
|
|
drsCMCPowerTableEntry |
1.3.6.1.4.1.674.10892.2.4.1.1 |
0004.0001.0001 This object defines the CMC power table entry. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
DrsCMCPowerTableEntry |
|
|
drsCMCPSUTable |
1.3.6.1.4.1.674.10892.2.4.2 |
0004.0002 This object defines the CMC PSU table. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
DrsCMCPSUTableEntry |
|
drsCMCPSUTableEntry |
1.3.6.1.4.1.674.10892.2.4.2.1 |
0004.0002.0001 This object defines the CMC PSU table entry. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
DrsCMCPSUTableEntry |
|
|
drsChassisIndex |
1.3.6.1.4.1.674.10892.2.4.1.1.1 |
0004.0001.0001.0001 This attribute defines the index
(one-based) of the associated chassis. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DellCMCPowerIndexRange |
|
|
drsPotentialPower |
1.3.6.1.4.1.674.10892.2.4.1.1.2 |
0004.0001.0001.0002 This attribute defines the power (in Watts) required by
the chassis infrastructure, plus the sum of the maximum power requirements
for all currently powered-on servers. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DellPowerReading |
|
|
drsIdlePower |
1.3.6.1.4.1.674.10892.2.4.1.1.3 |
0004.0001.0001.0003 This attribute defines the power (in Watts) required by
the chassis infrastructure, plus the sum of the minimum power requirements
for all currently powered-on servers. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DellPowerReading |
|
|
drsMaxPowerSpecification |
1.3.6.1.4.1.674.10892.2.4.1.1.4 |
0004.0001.0001.0004 This attribute defines the power limit (in Watts)
at which server throttling will take place. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DellPowerReading |
|
|
drsPowerSurplus |
1.3.6.1.4.1.674.10892.2.4.1.1.5 |
0004.0001.0001.0005 This attribute defines the power surplus (in Watts)
remaining above the drsPotentialPower reading. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DellPowerReading |
|
|
drsKWhCumulative |
1.3.6.1.4.1.674.10892.2.4.1.1.6 |
0004.0001.0001.0006 This attribute defines the cumulative chassis power
usage (in KWh) since last reset. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DellPowerReading |
|
|
drsKWhCumulativeTime |
1.3.6.1.4.1.674.10892.2.4.1.1.7 |
0004.0001.0001.0007 This attribute defines the timestamp of the most recent
chassis power accumulator reset. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DellTimestamp |
|
|
drsWattsPeakUsage |
1.3.6.1.4.1.674.10892.2.4.1.1.8 |
0004.0001.0001.0008 This attribute defines the chassis peak power
usage (in Watts) since last reset. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DellPowerReading |
|
|
drsWattsPeakTime |
1.3.6.1.4.1.674.10892.2.4.1.1.9 |
0004.0001.0001.0009 This attribute defines the timestamp of the most recent
chassis peak power usage. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DellTimestamp |
|
|
drsWattsMinUsage |
1.3.6.1.4.1.674.10892.2.4.1.1.10 |
0004.0001.0001.0010 This attribute defines the chassis mimimum power
usage (in Watts) since last reset. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DellPowerReading |
|
|
drsWattsMinTime |
1.3.6.1.4.1.674.10892.2.4.1.1.11 |
0004.0001.0001.0011 This attribute defines the timestamp of the most recent
chassis minimum power usage. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DellTimestamp |
|
|
drsWattsResetTime |
1.3.6.1.4.1.674.10892.2.4.1.1.12 |
0004.0001.0001.0012 This attribute defines the timestamp of the most recent
reset of the chassis min/peak Watts readings. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DellTimestamp |
|
|
drsWattsReading |
1.3.6.1.4.1.674.10892.2.4.1.1.13 |
0004.0001.0001.0013 This attribute defines the instantaneous chassis power
usage (in Watts). |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DellPowerReading |
|
|
drsAmpsReading |
1.3.6.1.4.1.674.10892.2.4.1.1.14 |
0004.0001.0001.0014 This attribute defines the instantaneous chassis current
usage (in Watts). |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DellPowerReading |
|
|
drsPSUChassisIndex |
1.3.6.1.4.1.674.10892.2.4.2.1.1 |
0004.0002.0001.0001 This attribute defines the index
(one-based) of the associated chassis. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DellCMCPowerIndexRange |
|
|
drsPSUIndex |
1.3.6.1.4.1.674.10892.2.4.2.1.2 |
0004.0002.0001.0002 This attribute defines the index
(one-based) of the associated CMC PSU. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DellCMCPSUIndexRange |
|
|
drsPSULocation |
1.3.6.1.4.1.674.10892.2.4.2.1.3 |
0004.0002.0001.0003 This attribute defines the location
of the CMC PSU. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DellString |
|
|
drsPSUMonitoringCapable |
1.3.6.1.4.1.674.10892.2.4.2.1.4 |
0004.0002.0001.0004 This attribute defines the PSU Monitoring
capabilities, or the absence of a PSU in this location. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DellCMCPSUCapable |
|
|
drsPSUVoltsReading |
1.3.6.1.4.1.674.10892.2.4.2.1.5 |
0004.0002.0001.0005 This attribute defines the instantaneous
PSU Voltage reading. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DellPowerReading |
|
|
drsPSUAmpsReading |
1.3.6.1.4.1.674.10892.2.4.2.1.6 |
0004.0002.0001.0006 This attribute defines the instantaneous
PSU Current reading. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DellPowerReading |
|
|
drsPSUWattsReading |
1.3.6.1.4.1.674.10892.2.4.2.1.7 |
0004.0002.0001.0007 This attribute defines the instantaneous
PSU Wattage reading. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DellPowerReading |
|
|
drsCMCServerTableEntry |
1.3.6.1.4.1.674.10892.2.5.1.1 |
0005.0001.0001 This object defines the CMC server table entry. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
DrsCMCServerTableEntry |
|
|
drsCASubSystem |
1.3.6.1.4.1.674.10892.2.20.10.1 |
0020.0010.0001 This attribute defines the Sub-System Name of the CMC Alert |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DellString |
|
|
drsCASSCurrStatus |
1.3.6.1.4.1.674.10892.2.20.10.2 |
0020.0010.0002 This attribute defines the Current Status of the Alerting
Sub-System |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DellStatus |
|
|
drsCASSPrevStatus |
1.3.6.1.4.1.674.10892.2.20.10.3 |
0020.0010.0003 This attribute defines the Previous Status of the Alerting
Sub-System |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DellStatus |
|
|
drsCASSChangeTime |
1.3.6.1.4.1.674.10892.2.20.10.4 |
0020.0010.0004 This attribute defines the Timestamp of Most Recent Change of
the Alerting Sub-System |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
TimeTicks |
|
|
drsCAMessage |
1.3.6.1.4.1.674.10892.2.20.10.5 |
0020.0010.0005 This attribute defines the CSSD message of the CMC Alert |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DellString |
|
|
alertCMCNormalTrap |
2002 |
The CMC reported a return-to-normal or informational event. |
TRAP-TYPE |
|
|
|
drsCA2MessageID |
1.3.6.1.4.1.674.10892.2.21.10.1 |
Message ID of the alert. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..8) |
|
drsCA2Message |
1.3.6.1.4.1.674.10892.2.21.10.2 |
Message describing the alert. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DellString |
|
|
drsCA2MessageArgs |
1.3.6.1.4.1.674.10892.2.21.10.3 |
Concatenated set of strings representing any message arguments
that were used to construct the alert message. Each message
argument string is enclosed in double quotes, and there is a
comma after the ending double quote of each message argument
string, except the last one. Any double quotes found within a
message argument string were preprocessed and changed to single
quotes. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DellString |
|
|
drsCA2FQDD |
1.3.6.1.4.1.674.10892.2.21.10.5 |
Fully qualified device descriptor of device causing the alert. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..512) |
|
alert2BatteryNormal |
2227 |
Battery state has returned to normal;
or battery presence had been detected. |
TRAP-TYPE |
|
|
|
alert2CMCWarning |
2546 |
Chassis Management Controller detected a warning. |
TRAP-TYPE |
|
|
|
alert2CMCFailure |
2545 |
Chassis Management Controller detected an error. |
TRAP-TYPE |
|
|
|
alert2StorageManagementWarning |
4178 |
Storage Management has detected a device independent warning
condition. There is no global status change associated with this
trap. |
TRAP-TYPE |
|
|
|
alert2StorageManagementFailure |
4177 |
Storage Management has detected a device independent error condition.
There is no global status change associated with this trap. |
TRAP-TYPE |
|
|
|
alert2CMCTestTrap |
10395 |
Test trap generated by CMC in response to a user request. |
TRAP-TYPE |
|
|
|
drsAlertSystem |
1.3.6.1.4.1.674.10892.2.5000.10.1 |
5000.0010.0001 Name of the system generating the alert. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(0..255) |
|
drsAlertTableIndexOID |
1.3.6.1.4.1.674.10892.2.5000.10.2 |
5000.0010.0002 0.0 |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OBJECT IDENTIFIER |
|
|
drsAlertMessage |
1.3.6.1.4.1.674.10892.2.5000.10.3 |
5000.0010.0003 Message describing the alert. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(0..1024) |
|
drsAlertCurrentStatus |
1.3.6.1.4.1.674.10892.2.5000.10.4 |
5000.0010.0004 Current status of object causing the alert. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DellStatus |
|
|
drsAlertPreviousStatus |
1.3.6.1.4.1.674.10892.2.5000.10.5 |
5000.0010.0005 Previous status of object causing the alert. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DellStatus |
|
|
drsAlertData |
1.3.6.1.4.1.674.10892.2.5000.10.6 |
5000.0010.0006 Alert data. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(0..1024) |
|
alertDrscAuthError |
1002 |
The RAC Authentication Failures during a time period have Exceeded a Threshold. |
TRAP-TYPE |
|
|
|
alertDrscLostESM |
1003 |
The RAC cannot communicate with the baseboard management controller (ESM). |
TRAP-TYPE |
|
|
|
alertDrscFoundESM |
1004 |
The RAC is communicating normally with the baseboard management controller (ESM). |
TRAP-TYPE |
|
|
|
alertDrscPowerOff |
1005 |
The RAC has detected a System power state change to powered-off. |
TRAP-TYPE |
|
|
|
alertDrscPowerOn |
1006 |
The RAC has detected a system power state change to powered-on. |
TRAP-TYPE |
|
|
|
alertDrscWatchdogExpired |
1007 |
The RAC has detected that the system watchdog has expired indicating a system hang. |
TRAP-TYPE |
|
|
|
alertDrscBattLow |
1008 |
The RAC Battery charge is below 25% indicating that the battery may only be able to power the DRSC for 8-10 minutes. |
TRAP-TYPE |
|
|
|
alertDrscTempCritical |
1011 |
The RAC Temperature probe has detected a failure (or critical) value. |
TRAP-TYPE |
|
|
|
alertDrscSELWarning |
1015 |
The RAC has detected a new event in the System Event Log with Severity: Warning. |
TRAP-TYPE |
|
|
|
alertDrscSELCritical |
1016 |
The RAC has detected a new event in the System Event Log with Severity: Critical. |
TRAP-TYPE |
|
|
|
alertDrscSELNormal |
1020 |
The RAC has detected a new event in the System Event Log with Severity: Normal. |
TRAP-TYPE |
|
|
|