ChrComIfOpticsOTS-SRC-MIB

File: ChrComIfOpticsOTS-SRC-MIB.mib (3082 bytes)

Imported modules

SNMPv2-SMI Chromatis-MIB ChrComIfifTable-MIB

Imported symbols

OBJECT-TYPE Counter32 Integer32
Unsigned32 chrComIfOptics chrComIfifIndex

Defined Types

ChrComIfOpticsOTS-SRCEntry  
SEQUENCE    
  chrComIfOpticsOtsSrcOutPower Integer32 -501..300
  chrComIfOpticsOtsSrcLOOPThr Integer32 -501..300
  chrComIfOpticsOtsSrcSafetyThr Integer32 -501..300
  chrComIfOpticsAlarmVector Unsigned32 0..4294967295
  chrComIfOpticsAlarmSeverityProfileIndex Unsigned32 0..4294967295

Defined Values

chrComIfOpticsOTS-SRCTable 1.3.6.1.4.1.3695.1.2.3.2
1. The OTS-SRC is managed only for the Ring side of the Metropolis Network (not for the Trib side). 2. When post-OPA exists, the preceding ADOM/OMDM does NOT have an OTS-SRC layer This layer should be grayed and not accessible to the user
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    ChrComIfOpticsOTS-SRCEntry

chrComIfOpticsOTS-SRCEntry 1.3.6.1.4.1.3695.1.2.3.2.1
Tok_String
Status: current Access: not-accessible
OBJECT-TYPE    
  ChrComIfOpticsOTS-SRCEntry  

chrComIfOpticsOtsSrcOutPower 1.3.6.1.4.1.3695.1.2.3.2.1.1
Total Optical Power Monitored at the output of the ADOM/OMDM/post-OPA/in-line-OPA.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 -501..300  

chrComIfOpticsOtsSrcLOOPThr 1.3.6.1.4.1.3695.1.2.3.2.1.2
This is a threshold on OTS-SRC total output Power indicating the existence of light energy emitted into the Ring.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -501..300  

chrComIfOpticsOtsSrcSafetyThr 1.3.6.1.4.1.3695.1.2.3.2.1.3
This is a threshold on OTS-SRC total output Power indicating that the light energy emitted into the Ring exceeds the safety threshold
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 -501..300  

chrComIfOpticsAlarmVector 1.3.6.1.4.1.3695.1.2.3.2.1.4
16 bit field. The following are bits relative positions (0=LSB), and the trap ID associated to each alarm state. 8. Ring-out loss of Optical power metropolisOTS-SRCLoop 9. Ring-out Optical Power output Safety Limit Crossing metropolisOTS-SRCSafety
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32 0..4294967295  

chrComIfOpticsAlarmSeverityProfileIndex 1.3.6.1.4.1.3695.1.2.3.2.1.5
Tok_String
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..4294967295