CTMMIBCUSTOM
File:
CTMMIBCUSTOM.mib (21592 bytes)
Imported modules
Imported symbols
Defined Values
version |
1.3.6.1.4.1.25868.1.1 |
Version of Web GUI - Version of Web GUI Interface
currently running on CTM |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
site |
1.3.6.1.4.1.25868.1.2 |
Site Name - Site name as stored on CTM |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
lastIP |
1.3.6.1.4.1.25868.1.3 |
Last IP Address Login - Last IP address captured
at Login Attempt |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
lastTime |
1.3.6.1.4.1.25868.1.4 |
Last Time Login - Last time of Login attempt |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
nSats |
1.3.6.1.4.1.25868.1.5 |
Number Satellites in View - Number of Satellites
in view of GPS Receiver Antenna being used for
timing calculations |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
pwrP |
1.3.6.1.4.1.25868.1.6 |
Master Primary Power - Master ?1? = Power OK,
?0? = Power Off or Low |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
pwrS |
1.3.6.1.4.1.25868.1.7 |
Master Secondary Power - Master ?1? = Power OK,
?0? = Power Off or Low |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
cbTrip |
1.3.6.1.4.1.25868.1.8 |
Master Circuit Breaker Trip Bit Code - Master
Breaker Tripped Code: 1=Port 1, 2=Port2, 4=Port
3, 8=Port4, 16=Port5, 32=Port6, 64=Port7, 128=Port8
Example: Code 5 means Port 3 and Port 1 Tripped |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
tempC |
1.3.6.1.4.1.25868.1.9 |
Master Temperature |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
voltsM1 |
1.3.6.1.4.1.25868.1.10 |
Master Primary Power In Voltage - In Tenths of
a Volt |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
voltsM2 |
1.3.6.1.4.1.25868.1.11 |
Master Secondary Power In Voltage - In Tenths
of a Volt |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
portOnM |
1.3.6.1.4.1.25868.1.12 |
Master Ports ON Enabled Status - Master ?1? =Sync
Enabled, ?0? = Sync Off listed in order ?Port1?,
?Port2?, ?Port3?, ?Port4?, ?Port5?, ?Port6?,
?Port7?, ?Port8? |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
portSyncM |
1.3.6.1.4.1.25868.1.13 |
Master Ports Sync Enabled Status - Master ?1?
=Sync Enabled, ?0? = Sync Off listed in order
?Port1?, ?Port2?, ?Port3?, ?Port4?, ?Port5?,
?Port6?, ?Port7?, ?Port8? |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
portPwrM1 |
1.3.6.1.4.1.25868.1.14 |
Master Power Port 1 - (in tenths of a Watt) delivered
on Port 1 |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
portPwrM2 |
1.3.6.1.4.1.25868.1.15 |
Master Power Port 2 - (in tenths of a Watt) delivered
on Port 2 |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
portPwrM3 |
1.3.6.1.4.1.25868.1.16 |
Master Power Port 3 - (in tenths of a Watt) delivered
on Port 3 |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
portPwrM4 |
1.3.6.1.4.1.25868.1.17 |
Master Power Port 4 - (in tenths of a Watt) delivered
on Port 4 |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
portPwrM5 |
1.3.6.1.4.1.25868.1.18 |
Master Power Port 5 - (in tenths of a Watt) delivered
on Port 5 |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
portPwrM6 |
1.3.6.1.4.1.25868.1.19 |
Master Power Port 6 - (in tenths of a Watt) delivered
on Port 6 |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
portPwrM7 |
1.3.6.1.4.1.25868.1.20 |
Master Power Port 7 - (in tenths of a Watt) delivered
on Port 7 |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
portPwrM8 |
1.3.6.1.4.1.25868.1.21 |
Master Power Port 8 - (in tenths of a Watt) delivered
on Port 8 |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
pwrSP |
1.3.6.1.4.1.25868.1.23 |
Slave Primary Power - Master ?1? = Power OK,
?0? = Power Off or Low |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
voltsS1 |
1.3.6.1.4.1.25868.1.27 |
Slave Primary Power In Voltage - In Tenths of
a Volt |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
voltsS2 |
1.3.6.1.4.1.25868.1.28 |
Slave Secondary Power In Voltage - In Tenths
of a Volt |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
portOnS |
1.3.6.1.4.1.25868.1.29 |
Slave Ports ON Enabled Status - Slave ?1? =Sync
Enabled, ?0? = Sync Off listed in order ?Port1?,
?Port2?, ?Port3?, ?Port4?, ?Port5?, ?Port6?,
?Port7?, ?Port8? |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
portSyncS |
1.3.6.1.4.1.25868.1.30 |
Slave Ports Sync Enabled Status - Slave ?1?
=Sync Enabled, ?0? = Sync Off listed in order
?Port1?, ?Port2?, ?Port3?, ?Port4?, ?Port5?,
?Port6?, ?Port7?, ?Port8? |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
portPwrS1 |
1.3.6.1.4.1.25868.1.31 |
Slave Power Port 1 - (in tenths of a Watt) delivered
on Port 1 |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
portPwrS2 |
1.3.6.1.4.1.25868.1.32 |
Slave Power Port 2 - (in tenths of a Watt) delivered
on Port 2 |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
portPwrS3 |
1.3.6.1.4.1.25868.1.33 |
Slave Power Port 3 - (in tenths of a Watt) delivered
on Port 3 |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
portPwrS4 |
1.3.6.1.4.1.25868.1.34 |
Slave Power Port 4 - (in tenths of a Watt) delivered
on Port 4 |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
portPwrS5 |
1.3.6.1.4.1.25868.1.35 |
Slave Power Port 5 - (in tenths of a Watt) delivered
on Port 5 |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
portPwrS6 |
1.3.6.1.4.1.25868.1.36 |
Slave Power Port 6 - (in tenths of a Watt) delivered
on Port 6 |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
portPwrS7 |
1.3.6.1.4.1.25868.1.37 |
Slave Power Port 7 - (in tenths of a Watt) delivered
on Port 7 |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
portPwrS8 |
1.3.6.1.4.1.25868.1.38 |
Slave Power Port 8 - (in tenths of a Watt) delivered
on Port 8 |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
modeReqM |
1.3.6.1.4.1.25868.1.39 |
Master CTM2 Port Type Setting - Master ?00?=Type
A (Canopy) ?10?=Type B (OFDM), ?01? = Type C
(POE 802.3at), ?11? (POE 802.3at 4 Pair), ?100?=(POE
24V mode, CTM2 C Only) listed in order ?Port1?,
?Port2?, ?Port3?, ?Port4?, ?Port5?, ?Port6?,
?Port7?, ?Port8? |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
trpCntGM1 |
1.3.6.1.4.1.25868.1.45 |
Master Auto Restart Count Port 1 - Number of Times
Auto Reset Feature has executed a Circuit Breaker
Restart on Port 1 |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
trpCntGM2 |
1.3.6.1.4.1.25868.1.46 |
Master Auto Restart Count Port 2 - Number of Times
Auto Reset Feature has executed a Circuit Breaker
Restart on Port 2 |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
trpCntGM3 |
1.3.6.1.4.1.25868.1.47 |
Master Auto Restart Count Port 3 - Number of Times
Auto Reset Feature has executed a Circuit Breaker
Restart on Port 3 |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
trpCntGM4 |
1.3.6.1.4.1.25868.1.48 |
Master Auto Restart Count Port 4 - Number of Times
Auto Reset Feature has executed a Circuit Breaker
Restart on Port 4 |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
trpCntGM5 |
1.3.6.1.4.1.25868.1.49 |
Master Auto Restart Count Port 5 - Number of Times
Auto Reset Feature has executed a Circuit Breaker
Restart on Port 5 |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
trpCntGM6 |
1.3.6.1.4.1.25868.1.50 |
Master Auto Restart Count Port 6 - Number of Times
Auto Reset Feature has executed a Circuit Breaker
Restart on Port 6 |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
trpCntGM7 |
1.3.6.1.4.1.25868.1.51 |
Master Auto Restart Count Port 7 - Number of Times
Auto Reset Feature has executed a Circuit Breaker
Restart on Port 7 |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
trpCntGM8 |
1.3.6.1.4.1.25868.1.52 |
Master Auto Restart Count Port 8 - Number of Times
Auto Reset Feature has executed a Circuit Breaker
Restart on Port 8 |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
trpCntBM1 |
1.3.6.1.4.1.25868.1.53 |
Master Ckt Breaker Auto Restart Fail Count Port
1 - Number of Times Auto Reset Feature has failed
to restart (after 7 tries) a Circuit Breaker
on Port 1 |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
trpCntBM2 |
1.3.6.1.4.1.25868.1.54 |
Master Ckt Breaker Auto Restart Fail Count Port
2 - Number of Times Auto Reset Feature has failed
to restart (after 7 tries) a Circuit Breaker
on Port 2 |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
trpCntBM3 |
1.3.6.1.4.1.25868.1.55 |
Master Ckt Breaker Auto Restart Fail Count Port
3 - Number of Times Auto Reset Feature has failed
to restart (after 7 tries) a Circuit Breaker
on Port 3 |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
trpCntBM4 |
1.3.6.1.4.1.25868.1.56 |
Master Ckt Breaker Auto Restart Fail Count Port
4 - Number of Times Auto Reset Feature has failed
to restart (after 7 tries) a Circuit Breaker
on Port 4 |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
trpCntBM5 |
1.3.6.1.4.1.25868.1.57 |
Master Ckt Breaker Auto Restart Fail Count Port
5 - Number of Times Auto Reset Feature has failed
to restart (after 7 tries) a Circuit Breaker
on Port 5 |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
trpCntBM6 |
1.3.6.1.4.1.25868.1.58 |
Master Ckt Breaker Auto Restart Fail Count Port
6 - Number of Times Auto Reset Feature has failed
to restart (after 7 tries) a Circuit Breaker
on Port 6 |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
trpCntBM7 |
1.3.6.1.4.1.25868.1.59 |
Master Ckt Breaker Auto Restart Fail Count Port
7 - Number of Times Auto Reset Feature has failed
to restart (after 7 tries) a Circuit Breaker
on Port 7 |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
trpCntBM8 |
1.3.6.1.4.1.25868.1.60 |
Master Ckt Breaker Auto Restart Fail Count Port
8 - Number of Times Auto Reset Feature has failed
to restart (after 7 tries) a Circuit Breaker
on Port 8 |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
masterCircuitBreakerTripCode |
5 |
Master Circuit Breaker Trip Code - Master Breaker Tripped
Code: 1=Port 1, 2=Port2, 4=Port 3, 8=Port4, 16=Port5,
32=Port6, 64=Port7, 128=Port8 Example: Code
5 means Port 3 and Port 1 Tripped |
TRAP-TYPE |
|
|
|