CPQSM2-MIB

File: CPQSM2-MIB.mib (83944 bytes)

Imported modules

RFC1155-SMI RFC1213-MIB RFC-1212
RFC-1215 CPQHOST-MIB

Imported symbols

Counter IpAddress DisplayString
OBJECT-TYPE TRAP-TYPE sysName
compaq cpqHoTrapFlags

Defined Types

CpqSm2OsCommonModuleEntry  
SEQUENCE    
  cpqSm2OsCommonModuleIndex INTEGER
  cpqSm2OsCommonModuleName DisplayString
  cpqSm2OsCommonModuleVersion DisplayString
  cpqSm2OsCommonModuleDate OCTET STRING
  cpqSm2OsCommonModulePurpose DisplayString

CpqSm2EventLogEntry  
SEQUENCE    
  cpqSm2EventLogIndex INTEGER
  cpqSm2EventLogNumber INTEGER
  cpqSm2EventLogDate OCTET STRING
  cpqSm2EventLogMessage DisplayString

CpqSm2CommSettingsEntry  
SEQUENCE    
  cpqSm2CommPort INTEGER
  cpqSm2CommType INTEGER
  cpqSm2CommBaudRate INTEGER
  cpqSm2CommParity INTEGER
  cpqSm2CommDataBits INTEGER
  cpqSm2CommStopBits INTEGER
  cpqSm2CommModemReset DisplayString
  cpqSm2CommModemInit DisplayString
  cpqSm2CommModemDialPrefix DisplayString
  cpqSm2CommPortInit DisplayString
  cpqSm2CommDialin INTEGER
  cpqSm2CommDialbackRequired INTEGER
  cpqSm2CommNonPppConnections INTEGER
  cpqSm2CommSnmpTrapDelivery INTEGER
  cpqSm2CommPageDelivery INTEGER
  cpqSm2CommPagerBaudRate INTEGER
  cpqSm2CommPagerParity INTEGER
  cpqSm2CommPagerDataBits INTEGER
  cpqSm2CommPagerStopBits INTEGER
  cpqSm2CommPcmciaModel DisplayString

CpqSm2NicConfigEntry  
SEQUENCE    
  cpqSm2NicLocation INTEGER
  cpqSm2NicModel DisplayString
  cpqSm2NicType INTEGER
  cpqSm2NicMacAddress OCTET STRING
  cpqSm2NicIpAddress IpAddress
  cpqSm2NicIpSubnetMask IpAddress
  cpqSm2NicEnabledStatus INTEGER
  cpqSm2NicDuplexState INTEGER
  cpqSm2NicSpeed INTEGER
  cpqSm2NicDhcpUse INTEGER
  cpqSm2NicCondition INTEGER
  cpqSm2NicMtu INTEGER
  cpqSm2NicGatewayIpAddress IpAddress
  cpqSm2NicRibFullQualDnsName DisplayString

CpqSm2NicStatsEntry  
SEQUENCE    
  cpqSm2NicStatsLocation INTEGER
  cpqSm2NicXmitBytes Counter
  cpqSm2NicXmitTotalPackets Counter
  cpqSm2NicXmitUnicastPackets Counter
  cpqSm2NicXmitNonUniPackets Counter
  cpqSm2NicXmitDiscardPackets Counter
  cpqSm2NicXmitErrorPackets Counter
  cpqSm2NicXmitQueueLength Counter
  cpqSm2NicRecvBytes Counter
  cpqSm2NicRecvTotalPackets Counter
  cpqSm2NicRecvUnicastPackets Counter
  cpqSm2NicRecvNonUniPackets Counter
  cpqSm2NicRecvDiscardPackets Counter
  cpqSm2NicRecvErrorPackets Counter
  cpqSm2NicRecvUnknownPackets Counter

Defined Values

cpqSm2 1.3.6.1.4.1.232.9
OBJECT IDENTIFIER    

cpqSm2MibRev 1.3.6.1.4.1.232.9.1
OBJECT IDENTIFIER    

cpqSm2Component 1.3.6.1.4.1.232.9.2
OBJECT IDENTIFIER    

cpqSm2Trap 1.3.6.1.4.1.232.9.3
OBJECT IDENTIFIER    

cpqSm2Interface 1.3.6.1.4.1.232.9.2.1
OBJECT IDENTIFIER    

cpqSm2Cntlr 1.3.6.1.4.1.232.9.2.2
OBJECT IDENTIFIER    

cpqSm2EventLog 1.3.6.1.4.1.232.9.2.3
OBJECT IDENTIFIER    

cpqSm2AsyncComm 1.3.6.1.4.1.232.9.2.4
OBJECT IDENTIFIER    

cpqSm2Nic 1.3.6.1.4.1.232.9.2.5
OBJECT IDENTIFIER    

cpqSm2OsCommon 1.3.6.1.4.1.232.9.2.1.4
OBJECT IDENTIFIER    

cpqSm2Products 1.3.6.1.4.1.232.9.4
OBJECT IDENTIFIER    

cpaSm2ProdEisaRemote 1.3.6.1.4.1.232.9.4.2
OBJECT IDENTIFIER    

cpqSm2ProdPCIRemote 1.3.6.1.4.1.232.9.4.3
OBJECT IDENTIFIER    

cpqSm2ProdRILOE 1.3.6.1.4.1.232.9.4.4
OBJECT IDENTIFIER    

cpqSm2ProdiLo 1.3.6.1.4.1.232.9.4.5
OBJECT IDENTIFIER    

cpqSm2ProdRILOEII 1.3.6.1.4.1.232.9.4.6
OBJECT IDENTIFIER    

cpqSm2MibRevMajor 1.3.6.1.4.1.232.9.1.1
The Major Revision level of the MIB. A change in the major revision level represents a major change in the architecture of the MIB. A change in the major revision level may indicate a significant change in the information supported and/or the meaning of the supported information. Correct interpretation of data may require a MIB document with the same major revision level.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

cpqSm2MibRevMinor 1.3.6.1.4.1.232.9.1.2
The Minor Revision level of the MIB. A change in the minor revision level may represent some minor additional support, no changes to any pre-existing information has occurred.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

cpqSm2MibCondition 1.3.6.1.4.1.232.9.1.3
Remote Insight/ Integrated Lights-Out condition. This represents the overall condition of the Remote Insight/ Integrated Lights-Out.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), ok(2), degraded(3), failed(4)  

cpqSm2OsCommonPollFreq 1.3.6.1.4.1.232.9.2.1.4.1
The Insight Agent's polling frequency. The frequency, in seconds, at which the Insight Agent requests information from the device driver. A frequency of zero (0) indicates that the Insight Agent retrieves the information upon request of a management station, it does not poll the device driver at a specific interval. If the poll frequency is zero (0) all attempts to write to this object will fail. If the poll frequency is non-zero, setting this value will change the polling frequency of the Insight Agent. Setting the poll frequency to zero (0) will always fail. An agent may choose to fail any request to change the poll frequency to a value that would severely impact system performance.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

cpqSm2OsCommonModuleTable 1.3.6.1.4.1.232.9.2.1.4.2
A table of software modules that provide an interface to the device this MIB describes.
Status: deprecated Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CpqSm2OsCommonModuleEntry

cpqSm2OsCommonModuleEntry 1.3.6.1.4.1.232.9.2.1.4.2.1
A description of a software module that provides an interface to the device this MIB describes.
Status: deprecated Access: not-accessible
OBJECT-TYPE    
  CpqSm2OsCommonModuleEntry  

cpqSm2OsCommonModuleIndex 1.3.6.1.4.1.232.9.2.1.4.2.1.1
A unique index for this module description.
Status: deprecated Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

cpqSm2OsCommonModuleName 1.3.6.1.4.1.232.9.2.1.4.2.1.2
The module name.
Status: deprecated Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

cpqSm2OsCommonModuleVersion 1.3.6.1.4.1.232.9.2.1.4.2.1.3
The module version in XX.YY format. Where XX is the major version number and YY is the minor version number. This field will be null (size 0) string if the agent cannot provide the module version.
Status: deprecated Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..5)  

cpqSm2OsCommonModuleDate 1.3.6.1.4.1.232.9.2.1.4.2.1.4
The module date. field octets contents range ===== ====== ======= ===== 1 1-2 year 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minute 0..59 6 7 second 0..60 (use 60 for leap-second) This field will be set to year = 0 if the agent cannot provide the module date. The hour, minute, and second field will be set to zero (0) if they are not relevant. The year field is set with the most significant octet first.
Status: deprecated Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(7)  

cpqSm2OsCommonModulePurpose 1.3.6.1.4.1.232.9.2.1.4.2.1.5
The purpose of the module described in this entry.
Status: deprecated Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

cpqSm2CntlrRomDate 1.3.6.1.4.1.232.9.2.2.1
Remote Insight/ Integrated Lights-Out ROM Date. The firmware date format is mm/dd/yyyy format.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..10)  

cpqSm2CntlrRomRevision 1.3.6.1.4.1.232.9.2.2.2
Remote Insight/ Integrated Lights-Out ROM Revision. The revision of the firmware on the Remote Insight/ Integrated Lights-Out.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..5)  

cpqSm2CntlrVideoStatus 1.3.6.1.4.1.232.9.2.2.3
Remote Insight/ Integrated Lights-Out Video Hardware Status. The following values are defined: other(1) The Insight Agent is unable to determine the status of the Remote Insight/ Integrated Lights-Out video. enabled(2) The Remote Insight/ Integrated Lights-Out video is enabled. disabled(3) The Remote Insight/ Integrated Lights-Out video is disabled.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), enabled(2), disabled(3)  

cpqSm2CntlrBatteryEnabled 1.3.6.1.4.1.232.9.2.2.4
Remote Insight Battery Enabled. The following values are defined: other(1) The Insight Agent is unable to determine the status of the Remote Insight battery. enabled(2) The Remote Insight battery is present and is enabled. disabled(3) The Remote Insight battery is present and is disabled. noBattery(4) This Remote Insight model does not use a battery.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER other(1), enabled(2), disabled(3), noBattery(4)  

cpqSm2CntlrBatteryStatus 1.3.6.1.4.1.232.9.2.2.5
Remote Insight Battery Status. The following values are defined: other(1) The Insight Agent is unable to determine if the battery needs replacement. batteryOk(2) The Remote Insight battery is OK. batteryFailed(3) The Remote Insight battery needs replacement. batteryDisconnected(4) The Remote Insight battery is disconnected.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), batteryOk(2), batteryFailed(3), batteryDisconnected(4)  

cpqSm2CntlrBatteryPercentCharged 1.3.6.1.4.1.232.9.2.2.6
Remote Insight Battery Percent Charged. The Remote Insight battery recharge level.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..100  

cpqSm2CntlrAlertStatus 1.3.6.1.4.1.232.9.2.2.7
Remote Insight/ Integrated Lights-Out Alerting Status. The following values are defined: other(1) The Insight Agent is unable to determine the status of Remote Insight alerting. enabled(2) Remote Insight/ Integrated Lights-Out alerting is enabled. disabled(3) Remote Insight/ Integrated Lights-Out alerting is disabled.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER other(1), enabled(2), disabled(3)  

cpqSm2CntlrPendingAlerts 1.3.6.1.4.1.232.9.2.2.8
Pending Remote Insight/ Integrated Lights-Out alerts. The following values are defined: other(1) The Insight Agent is unable to determine the state of Remote Insight pending alerts. noAlertsPending(2) No Remote Insight/ Integrated Lights-Out alerts are pending. All alerts have been delivered. alertsPending(3) Remote Insight/ Integrated Lights-Out alerts are pending. There are alerts remaining to be sent. clearPendingAlerts(4) This value is set to clear any Remote Insight/ Integrated Lights-Out alerts that have not been sent.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER other(1), noAlertsPending(2), alertsPending(3), clearPendingAlerts(4)  

cpqSm2CntlrSelfTestErrors 1.3.6.1.4.1.232.9.2.2.9
Remote Insight/ Integrated Lights-Out Self Test Errors. This is a collection of post error flags. Each bit has the following meaning when it is on (1): Bit 17-31: RESERVED: Always 0. Bit 16: I2C error. Bit 15: EEPROM error. Bit 14: SRAM error. Bit 13: CPLD error. Bit 12: Mouse interface error. Bit 11: NIC Error Bit 10: PCMCIA Error Bit 9: Video Error Bit 8: NVRAM write / read / verify error. Bit 7: NVRAM interface error. Bit 6: Battery interface error. Bit 5: Keyboard interface error. Bit 4: Serial port UART error. Bit 3: Modem UART error. Bit 2: Modem firmware error. Bit 1: Memory test error. Bit 0: Busmaster I/O read error. NOTE: bit 31 is the most significant bit, bit 0 is the least significant. A value of 0 means no errors have occurred.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqSm2CntlrAgentLocation 1.3.6.1.4.1.232.9.2.2.10
Remote Insight/ Integrated Lights-Out Agent Location. The following values are defined: hostOsAgent(1) The Remote Insight/ Integrated Lights-Out MIB information is provided by the host OS agents. firmwareAgent(2) The Remote Insight/ Integrated Lights-Out MIB information is provided by the EISA Remote Insight/ Integrated Lights-Out firmware. remoteInsightPciFirmwareAgent(3) The Remote Insight/ Integrated Lights-Out MIB information is provided by the PCI Remote Insight/ Integrated Lights-Out firmware. enclosureFirmwareAgent(4) The Remote Insight/ Integrated Lights-Out MIB information is provided by a rack enclosure firmware agent.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER hostOsAgent(1), firmwareAgent(2), remoteInsightPciFirmwareAgent(3), enclosureFirmwareAgent(4)  

cpqSm2CntlrLastDataUpdate 1.3.6.1.4.1.232.9.2.2.11
The date and time that the Remote Insight/ Integrated Lights-Out offline data was last updated. field octets contents range ===== ====== ======= ===== 1 1-2 year 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minute 0..59 6 7 second 0..60 (use 60 for leap-second) This field will be set to year = 0 if the agent cannot provide the date and time. The hour, minute, and second field will be set to zero (0) if they are not relevant. The year field is set with the most significant octet first.
Status: deprecated Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(7)  

cpqSm2CntlrDataStatus 1.3.6.1.4.1.232.9.2.2.12
Remote Insight/ Integrated Lights-Out Host OS Data Status. The following values are defined: other(1) The Insight Agent is unable to determine the status of the host OS data. noData(2) There is no data available for the host system OS. onlineData(3) Data is available from the host OS Insight Agent. offlineData(4) A backup copy of data is available from the Remote Insight/ Integrated Lights-Out firmware agent.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), noData(2), onlineData(3), offlineData(4)  

cpqSm2CntlrColdReboot 1.3.6.1.4.1.232.9.2.2.13
Remote Insight/ Integrated Lights-Out Server Cold Reboot The following values are defined: notAvailable(1) Cold reboot of the system is not available. available(2) Cold reboot of the system is available. doColdReboot(3) This value is set to cause a cold reboot of the system.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notAvailable(1), available(2), doColdReboot(3)  

cpqSm2CntlrBadLoginAttemptsThresh 1.3.6.1.4.1.232.9.2.2.14
Maximum Unauthorized Login Attempts Threshold. This is the threshold for consecutive unsuccessful login attempts. When this threshold is exceeded, a trap is sent.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqSm2CntlrBoardSerialNumber 1.3.6.1.4.1.232.9.2.2.15
Remote Insight/ Integrated Lights-Out Serial Number. The Serial Number of this Remote Insight/ Integrated Lights-Out.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..40)  

cpqSm2CntlrRemoteSessionStatus 1.3.6.1.4.1.232.9.2.2.16
Remote Insight/ Integrated Lights-Out Session Status. The following values are defined: other(1) The Insight Agent is unable to determine the status of a Remote Insight session. active(2) A Remote Insight/ Integrated Lights-Out session is active. inactive(3) There is no active Remote Insight/ Integrated Lights-Out session.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), active(2), inactive(3)  

cpqSm2CntlrInterfaceStatus 1.3.6.1.4.1.232.9.2.2.17
Remote Insight/ Integrated Lights-Out Interface Status. The following values are defined: other(1) The Insight Agent is unable to determine the status of the Remote Insight/ Integrated Lights-Out interface. ok(2) The Remote Insight/ Integrated Lights-Out firmware is responding to commands. notResponding(3) The Remote Insight/ Integrated Lights-Out firmware is not responding to commands.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), ok(2), notResponding(3)  

cpqSm2CntlrSystemId 1.3.6.1.4.1.232.9.2.2.18
Remote Insight/ Integrated Lights-Out System ID. A number used to identify this system in Remote Insight/ Integrated Lights-Out pager alerts.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..9)  

cpqSm2CntlrKeyboardCableStatus 1.3.6.1.4.1.232.9.2.2.19
Remote Insight Keyboard Cable Status. The following values are defined: other(1) The Insight Agent is unable to determine if the keyboard cable is connected to the Remote Insight. connected(2) The keyboard cable is connected to the Remote Insight. disconnected(3) The keyboard cable is not connected to the Remote Insight.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), connected(2), disconnected(3)  

cpqSm2ServerIpAddress 1.3.6.1.4.1.232.9.2.2.20
The IP address for this servers connection to the Remote Insight/ Integrated Lights-Out. This address is used to communicate remotely to the host server via the Remote Insight/ Integrated Lights-Out.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

cpqSm2CntlrModel 1.3.6.1.4.1.232.9.2.2.21
Remote Insight/ Integrated Lights-Out Model. The following values are defined: other(1) The Insight Agent is unable to determine the model of the Remote Insight/ Integrated Lights-Out. eisaRemoteInsightBoard(2) This is the EISA Remote Insight. pciRemoteInsightBoard(3) This is the PCI Remote Insight. pciLightsOutRemoteInsightBoard(4) This is the Remote Insight Lights-Out Edition. pciIntegratedLightsOutRemoteInsight(5) This is Integrated Remote Insight Lights-Out Edition. pciLightsOutRemoteInsightBoardII(6) This is the Remote Insight Lights-Out Edition version II. pciIntegratedLightsOutRemoteInsight2(7) This is the Integrated Lights-Out 2 Edition. pciLightsOut100series(8) This is the Lights-Out 100 Edition for 100 Series of ProLiant servers.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), eisaRemoteInsightBoard(2), pciRemoteInsightBoard(3), pciLightsOutRemoteInsightBoard(4), pciIntegratedLightsOutRemoteInsight(5), pciLightsOutRemoteInsightBoardII(6), pciIntegratedLightsOutRemoteInsight2(7), pciLightsOut100series(8)  

cpqSm2CntlrSelfTestErrorMask 1.3.6.1.4.1.232.9.2.2.22
Remote Insight/ Integrated Lights-Out Self Test Error Mask. Each bit in this mask corresponds to a bit in the MIB variable cpqSm2CntlrSelfTestErrors. If the mask bit is a 1, then the corresponding bit in cpqSm2CntlrSelfTestErrors is relevant to the particular version of the Remote Insight/ Integrated Lights-Out. This variable is necessary since the different versions of the Remote Insight/ Integrated Lights-Out hardware have different subsets of tests that are performed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqSm2CntlrMouseCableStatus 1.3.6.1.4.1.232.9.2.2.23
Remote Insight Mouse Cable Status. The following values are defined: other(1) The Insight Agent is unable to determine if the mouse cable is connected to the Remote Insight. connected(2) The mouse cable is connected to the Remote Insight. disconnected(3) The mouse cable is not connected to the Remote Insight.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), connected(2), disconnected(3)  

cpqSm2CntlrVirtualPowerCableStatus 1.3.6.1.4.1.232.9.2.2.24
Remote Insight Virtual Power Cable Status. The following values are defined: other(1) The Insight Agent is unable to determine if the virtual power cable is connected to the Remote Insight. connected(2) The virtual power cable is connected to the Remote Insight. disconnected(3) The virtual power cable is not connected to the Remote Insight. notApplicable(4) Not Applicable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), connected(2), disconnected(3), notApplicable(4)  

cpqSm2CntlrExternalPowerCableStatus 1.3.6.1.4.1.232.9.2.2.25
Remote Insight External Power Cable Status. The following values are defined: other(1) The Insight Agent is unable to determine if the External or Internal power cable connections to the Remote Insight. externallyConnected(2) Just External power cable is connected to the Remote Insight. disconnected(3) Both External and Internal power cables are disconnected from the Remote Insight. internallyConnected(4) Just Internal power cable is connected to the Remote Insight. externallyAndInternallyConnected(5) Both External and Internal power cables are connected to the Remote Insight. notApplicable(6) Not Applicable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), externallyConnected(2), disconnected(3), internallyConnected(4), externallyAndInternallyConnected(5), notApplicable(6)  

cpqSm2CntlrHostGUID 1.3.6.1.4.1.232.9.2.2.26
The globally unique identifier of this server. This variable can by used by management stations to correlate the Remote Insight/ Integrated Lights-Out controller to the server containing the controller. This variable is identical to the variable 'cpqHoGUID' which is returned from the CPQHOST.MIB.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(16)  

cpqSm2CntlriLOSecurityOverrideSwitchState 1.3.6.1.4.1.232.9.2.2.27
Integrated Lights-Out Security Override Switch State. The following values are defined: notSupported(1) The iLO Security Override Switch state is not supported on this model of Integrated Lights-Out. set(2) The iLO Security Override Switch is set, which implies security is disabled. notSet(3) The iLO Security Override Switch is not set, which implies normal secure operation.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notSupported(1), set(2), notSet(3)  

cpqSm2CntlrHardwareVer 1.3.6.1.4.1.232.9.2.2.28
Hardware Version of Remote Insight/ Integrated Lights-Out.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqSm2CntlrAction 1.3.6.1.4.1.232.9.2.2.29
Remote Insight/ Integrated Lights-Out Action Flags. This is a collection of flags used to indicate the various options available. ResetSupportBit: If bit-0 is set to 1, the option is available. If bit-0 is set to 0, the option is NOT available. iLOAlerts If bit-1 is set to 1, iLO alerts are enabled. If bit-2 is set to 1, iLO alerts are disabled. These two bits should never have the same value. HostAlerts If bit-3 is set to 1, Host alerts are enabled. If bit-4 is set to 1, Host alerts are disabled. These two bits should never have the same value. Bit-31 is used to execute the set operation. NOTE: bit 31 is the most significant bit, bit 0 is the least significant. Status This is a collection of flags. Each bit has the following meaning when it is on (1): Bit 0: Reset Supported Bit 1: iLO Alerts Enabled Bit 2: iLO Alerts Disabled Bit 3: Host Alerts Enabled Bit 4: Host Alerts Disabled Bit 5-30: RESERVED Bit 31: Execute Set
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

cpqSm2CntlrLicenseActive 1.3.6.1.4.1.232.9.2.2.30
Remote Insight License State. The following values are defined: none(1) The Insight Agent is unable to determine the active license or no license is installed. iloAdvanced(2) iLO Advanced license is installed. iloLight(3) iLO Light license is installed. iloSelect(4) iLO Select license is installed. iloStandard(5) iLO 2 Standard for HP BladeSystem license is installed.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER none(1), iloAdvanced(2), iloLight(3), iloSelect(4), iloStandard(5)  

cpqSm2CntlrLicenseKey 1.3.6.1.4.1.232.9.2.2.31
iLO Active ASCII License key string. On implicitly licensed systems like blades, a license will be indicated as installed, although the key value may be blank
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(32)  

cpqSm2EventTotalEntries 1.3.6.1.4.1.232.9.2.3.1
The number of entries in the Remote Insight/ Integrated Lights-Out event log. Setting the number of entries to 0 clears the Remote Insight/ Integrated Lights-Out event log. Setting the number of entries to something other than 0 will always fail.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

cpqSm2EventLogTable 1.3.6.1.4.1.232.9.2.3.2
A table of event log descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CpqSm2EventLogEntry

cpqSm2EventLogEntry 1.3.6.1.4.1.232.9.2.3.2.1
An event log description.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  CpqSm2EventLogEntry  

cpqSm2EventLogIndex 1.3.6.1.4.1.232.9.2.3.2.1.1
An index that uniquely specifies this entry.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqSm2EventLogNumber 1.3.6.1.4.1.232.9.2.3.2.1.2
A number assigned by the Remote Insight/ Integrated Lights-Out firmware.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqSm2EventLogDate 1.3.6.1.4.1.232.9.2.3.2.1.3
The time and date for this event log entry. field octets contents range ===== ====== ======= ===== 1 1-2 year 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minute 0..59 6 7 second 0..60 (use 60 for leap-second) This field will be set to year = 0 if the agent cannot provide the time and date. The hour, minute, and second field will be set to zero (0) if they are not relevant. The year field is set with the most significant octet first.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(7)  

cpqSm2EventLogMessage 1.3.6.1.4.1.232.9.2.3.2.1.4
The message text for this event log entry.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..100)  

cpqSm2CommSettingsTable 1.3.6.1.4.1.232.9.2.4.1
The list of communication settings for the Remote Insight.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CpqSm2CommSettingsEntry

cpqSm2CommSettingsEntry 1.3.6.1.4.1.232.9.2.4.1.1
A defined port's communication settings for the Remote Insight.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  CpqSm2CommSettingsEntry  

cpqSm2CommPort 1.3.6.1.4.1.232.9.2.4.1.1.1
Remote Insight Communications Port. The following values are defined: internal(1) This is the Remote Insight internal modem port. auxiliary(2) This is the Remote Insight auxiliary port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER internal(1), auxiliary(2)  

cpqSm2CommType 1.3.6.1.4.1.232.9.2.4.1.1.2
Remote Insight Communications Type. The following values are defined: other(1) The Insight Agent is unable to determine the communications type. none(2) There is nothing configured on this port. modem(3) A modem is configured on this port. nulModem(4) A Null Modem cable is configured on this port. This type of connection is only supported on the Remote Insight auxiliary port. xonXoff(5) An XON/XOFF 3-wire interface is configured on this port. This type of connection is only supported on the Remote Insight auxiliary port.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), none(2), modem(3), nulModemCable(4), xonXoff(5)  

cpqSm2CommBaudRate 1.3.6.1.4.1.232.9.2.4.1.1.3
The baud rate to be used over this communication medium by the Remote Insight.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqSm2CommParity 1.3.6.1.4.1.232.9.2.4.1.1.4
Remote Insight Communications Parity. The following values are defined: other(1) The Insight Agent is unable to determine the parity setting. none(2) This port is set for no parity. odd(3) This port is set for odd parity. even(4) This port is set for even parity.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), none(2), odd(3), even(4)  

cpqSm2CommDataBits 1.3.6.1.4.1.232.9.2.4.1.1.5
Remote Insight Communications Data Bits. The following values are defined: other(1) The Insight Agent is unable to determine the data bits setting. sevenBit(2) This port is set for seven data bits. eight(3) This port is set for eight data bits.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), sevenBits(2), eightBits(3)  

cpqSm2CommStopBits 1.3.6.1.4.1.232.9.2.4.1.1.6
Remote Insight Communications Stop Bits. The following values are defined: other(1) The Insight Agent is unable to determine the stop bits setting. oneBit(2) This port is set for one stop data bit. twoBits(3) This port is set for two stop bits.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), oneBit(2), twoBits(3)  

cpqSm2CommModemReset 1.3.6.1.4.1.232.9.2.4.1.1.7
The string that is sent to reset the modem.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..42)  

cpqSm2CommModemInit 1.3.6.1.4.1.232.9.2.4.1.1.8
The string that is sent to initialize the modem.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..42)  

cpqSm2CommModemDialPrefix 1.3.6.1.4.1.232.9.2.4.1.1.9
The string that is prepended to phone numbers before dialing.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..42)  

cpqSm2CommPortInit 1.3.6.1.4.1.232.9.2.4.1.1.10
The string that is sent to the auxiliary port before the modem is reset.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..42)  

cpqSm2CommDialin 1.3.6.1.4.1.232.9.2.4.1.1.11
Comm Dial-in. The following values are defined: other(1) The Insight Agent is unable to determine the status of dialin. enabled(2) Dialing in to this modem is enabled. disabled(3) Dialing in to this modem is disabled.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), enabled(2), disabled(3)  

cpqSm2CommDialbackRequired 1.3.6.1.4.1.232.9.2.4.1.1.12
Remote Insight Dialback Required. The following values are defined: other(1) The Insight Agent is unable to determine the dialback required setting. required(2) Dialback is required for all users. notRequired(3) Dialback is not required. It is optional on a per user basis.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), required(2), notRequired(3)  

cpqSm2CommNonPppConnections 1.3.6.1.4.1.232.9.2.4.1.1.13
Non-PPP connections. The following values are defined: other(1) The Insight Agent is unable to determine the status of the non-PPP connections variable. enabled(2) Non-PPP connections are allowed on this port. disabled(3) Non-PPP connections are not allowed on this port. Only PPP sessions are accepted.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), enabled(2), disabled(3)  

cpqSm2CommSnmpTrapDelivery 1.3.6.1.4.1.232.9.2.4.1.1.14
SNMP Trap Delivery. The following values are defined: other(1) The Insight Agent is unable to determine the status of SNMP Trap delivery. enabled(2) SNMP trap delivery is enabled. The Remote Insight firmware will use this port to deliver SNMP traps. disabled(3) SNMP Trap delivery is disabled. The Remote Insight firmware will not use this port to deliver SNMP traps.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), enabled(2), disabled(3)  

cpqSm2CommPageDelivery 1.3.6.1.4.1.232.9.2.4.1.1.15
Page Delivery. The following values are defined: other(1) The Insight Agent is unable to determine the status of page delivery. enabled(2) Page delivery is enabled. The Remote Insight firmware will use this port to deliver pages. disabled(3) Page delivery is disabled. The Remote Insight firmware will not use this port to deliver pages.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), enabled(2), disabled(3)  

cpqSm2CommPagerBaudRate 1.3.6.1.4.1.232.9.2.4.1.1.16
The baud rate to be used for pager communications over this medium by the Remote Insight.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqSm2CommPagerParity 1.3.6.1.4.1.232.9.2.4.1.1.17
Remote Insight Communications Pager Parity. The following values are defined: other(1) The Insight Agent is unable to determine the pager parity setting. none(2) This port is set for no parity when paging. odd(3) This port is set for odd parity when paging. even(4) This port is set for even parity when paging.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), none(2), odd(3), even(4)  

cpqSm2CommPagerDataBits 1.3.6.1.4.1.232.9.2.4.1.1.18
Remote Insight Communications Pager Data Bits. The following values are defined: other(1) The Insight Agent is unable to determine the data bits setting. sevenBit(2) This port is set for seven data bits when paging. eight(3) This port is set for eight data bits when paging.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), sevenBits(2), eightBits(3)  

cpqSm2CommPagerStopBits 1.3.6.1.4.1.232.9.2.4.1.1.19
Remote Insight Communications Pager Stop Bits. The following values are defined: other(1) The Insight Agent is unable to determine the stop bits setting. oneBit(2) This port is set for one stop data bit when paging. twoBits(3) This port is set for two stop bits when paging.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), oneBit(2), twoBits(3)  

cpqSm2CommPcmciaModel 1.3.6.1.4.1.232.9.2.4.1.1.20
Remote Insight Network PCMCIA Card Model. This is a NULL terminated ASCII string. If the agent cannot determine the model name, it should return a NULL string.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

cpqSm2NicConfigTable 1.3.6.1.4.1.232.9.2.5.1
The list of network interface configuration settings for the Remote Insight/ Integrated Lights-Out.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CpqSm2NicConfigEntry

cpqSm2NicConfigEntry 1.3.6.1.4.1.232.9.2.5.1.1
A defined nic's configuration settings for the Remote Insight/ Integrated Lights-Out.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  CpqSm2NicConfigEntry  

cpqSm2NicLocation 1.3.6.1.4.1.232.9.2.5.1.1.1
Location of the Network Interface Controller associated with the Remote Insight/ Integrated Lights-Out. The following values are defined: other(1) The Insight Agent is unable to determine type of network interface controller. embedded(2) This is an embedded network interface controller. pcmcia(3) This is a PCMCIA network interface controller.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), embedded(2), pcmcia(3)  

cpqSm2NicModel 1.3.6.1.4.1.232.9.2.5.1.1.2
Remote Insight/ Integrated Lights-Out Network Interface Controller Model. This is a NULL terminated ASCII string. If the agent cannot determine the model name, it should return a NULL string.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

cpqSm2NicType 1.3.6.1.4.1.232.9.2.5.1.1.3
Remote Insight/ Integrated Lights-Out Network Interface Controller Type. The following values are defined: other(1) The Insight Agent is unable to determine type of network interface controller. ethernet(2) This is an ethernet network interface controller. tokenRing(3) This is a token ring network interface controller.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), ethernet(2), tokenRing(3)  

cpqSm2NicMacAddress 1.3.6.1.4.1.232.9.2.5.1.1.4
The MAC Address of the Network Interface Controller associated with the Remote Insight/ Integrated Lights-Out. This is a 6 octet address in the 'canonical' order defined by IEEE 802.1a, i.e., as if it were transmitted least significant bit first, even though 802.5 (in contrast to other 802.x protocols) requires MAC addresses to be transmitted most significant bit first. 16-bit addresses, if needed, are represented by setting their upper 4 octets to all 0's, i.e., AAFF would be represented as 00000000AAFF.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(6)  

cpqSm2NicIpAddress 1.3.6.1.4.1.232.9.2.5.1.1.5
Remote Insight/ Integrated Lights-Out Network Interface Controller IP Address. The IP address for the network interface controller associated with the Remote Insight/ Integrated Lights-Out. All octets should be set to 0xff if there is not an IP address associated with the NIC. The order will be in network byte order (i.e. MSB first.)
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

cpqSm2NicIpSubnetMask 1.3.6.1.4.1.232.9.2.5.1.1.6
Remote Insight/ Integrated Lights-Out Network Interface Controller Subnet Mask.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

cpqSm2NicEnabledStatus 1.3.6.1.4.1.232.9.2.5.1.1.7
Remote Insight/ Integrated Lights-Out Network Interface Controller Enabled Status The following values are defined: other(1) The Insight Agent is unable to determine type of network interface controller enabled status enabled(2) This network interface controller is enabled. disabled(3) This network interface controller is disabled.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), enabled(2), disabled(3)  

cpqSm2NicDuplexState 1.3.6.1.4.1.232.9.2.5.1.1.8
Remote Insight/ Integrated Lights-Out Network Interface Controller Enabled Status. The following values are defined: other(1) The Insight Agent is unable to determine type of network interface controller duplex state. halfDuplex(2) This network interface controller is half duplex. fullDuplex(3) This network interface controller is full duplex. notSupported(4) This network interface controller is does not support duplex state.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), halfDuplex(2), fullDuplex(3), notSupported(4)  

cpqSm2NicSpeed 1.3.6.1.4.1.232.9.2.5.1.1.9
Remote Insight/ Integrated Lights-Out Network Interface Controller Speed. The speed of the network interface controller in megabits per second.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqSm2NicDhcpUse 1.3.6.1.4.1.232.9.2.5.1.1.10
Remote Insight/ Integrated Lights-Out Network Interface Controller DHCP Usage The following values are defined: other(1) The Insight Agent is unable to determine if DHCP is supported for this network interface controller. enabled(2) DHCP usage is enabled for this network interface controller. disabled(3) DHCP usage is disabled for this network interface controller.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), enabled(2), disabled(3)  

cpqSm2NicCondition 1.3.6.1.4.1.232.9.2.5.1.1.11
Remote Insight/ Integrated Lights-Out Network Interface Controller condition. This represents the overall condition of the Remote Insight/ Integrated Lights-Out Network Interface Controller (NIC).
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), ok(2), degraded(3), failed(4)  

cpqSm2NicMtu 1.3.6.1.4.1.232.9.2.5.1.1.12
Remote Insight/ Integrated Lights-Out Network Interface Maximum Transfer Unit. The maximum packet size (in bytes) of the network interface controller.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqSm2NicGatewayIpAddress 1.3.6.1.4.1.232.9.2.5.1.1.13
Remote Insight/ Integrated Lights-Out Network Interface Controller Default Gateway IP Address. The Default Gateway IP address for the network interface controller associated with the Remote Insight/ Integrated Lights-Out. If cpqSm2NicDhcpUse is enabled(2), this is the DHCP supplied gateway. If cpqSm2NicDhcpUse is disabled(3), this is the static gateway. The order will be in network byte order (i.e. MSB first.)
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

cpqSm2NicRibFullQualDnsName 1.3.6.1.4.1.232.9.2.5.1.1.14
Remote Insight/ Integrated Lights-Out Fully Qualified DNS Name. The Fully Qualified DNS Name assigned to this Remote Insight/ Integrated Lights-Out. This is composed of the DNS name and the Domain name associated with the Remote Insight/ Integrated Lights-Out.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..180)  

cpqSm2NicStatsTable 1.3.6.1.4.1.232.9.2.5.2
The list of network interface configuration settings for the Remote Insight/ Integrated Lights-Out.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CpqSm2NicStatsEntry

cpqSm2NicStatsEntry 1.3.6.1.4.1.232.9.2.5.2.1
A defined nic's configuration settings for the Remote Insight/ Integrated Lights-Out.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  CpqSm2NicStatsEntry  

cpqSm2NicStatsLocation 1.3.6.1.4.1.232.9.2.5.2.1.1
Location of the Network Interface Controller associated with the Remote Insight/ Integrated Lights-Out. The following values are defined: other(1) The Insight Agent is unable to determine type of network interface controller. embedded(2) This is an embedded network interface controller. pcmcia(3) This is a PCMCIA network interface controller.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), embedded(2), pcmcia(3)  

cpqSm2NicXmitBytes 1.3.6.1.4.1.232.9.2.5.2.1.2
Remote Insight/ Integrated Lights-Out Network Interface Controller Bytes Transmitted.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cpqSm2NicXmitTotalPackets 1.3.6.1.4.1.232.9.2.5.2.1.3
Remote Insight/ Integrated Lights-Out Network Interface Controller Total Transmit Packets.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cpqSm2NicXmitUnicastPackets 1.3.6.1.4.1.232.9.2.5.2.1.4
Remote Insight/ Integrated Lights-Out Network Interface Controller Unicast Transmit Packets.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cpqSm2NicXmitNonUniPackets 1.3.6.1.4.1.232.9.2.5.2.1.5
Remote Insight/ Integrated Lights-Out Network Interface Controller Non-Unicast Transmit Packets.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cpqSm2NicXmitDiscardPackets 1.3.6.1.4.1.232.9.2.5.2.1.6
Remote Insight/ Integrated Lights-Out Network Interface Controller Total Transmit Discarded Packets.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cpqSm2NicXmitErrorPackets 1.3.6.1.4.1.232.9.2.5.2.1.7
Remote Insight/ Integrated Lights-Out Network Interface Controller Total Error Transmit Packets.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cpqSm2NicXmitQueueLength 1.3.6.1.4.1.232.9.2.5.2.1.8
Remote Insight/ Integrated Lights-Out Network Interface Controller Number of Outstanding Packets in Transmit Queue.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cpqSm2NicRecvBytes 1.3.6.1.4.1.232.9.2.5.2.1.9
Remote Insight/ Integrated Lights-Out Network Interface Controller Bytes Received.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cpqSm2NicRecvTotalPackets 1.3.6.1.4.1.232.9.2.5.2.1.10
Remote Insight/ Integrated Lights-Out Network Interface Controller Total Receive Packets.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cpqSm2NicRecvUnicastPackets 1.3.6.1.4.1.232.9.2.5.2.1.11
Remote Insight/ Integrated Lights-Out Network Interface Controller Unicast Receive Packets.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cpqSm2NicRecvNonUniPackets 1.3.6.1.4.1.232.9.2.5.2.1.12
Remote Insight/ Integrated Lights-Out Network Interface Controller Non-Unicast Receive Packets.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cpqSm2NicRecvDiscardPackets 1.3.6.1.4.1.232.9.2.5.2.1.13
Remote Insight/ Integrated Lights-Out Network Interface Controller Total Receive Discarded Packets.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cpqSm2NicRecvErrorPackets 1.3.6.1.4.1.232.9.2.5.2.1.14
Remote Insight/ Integrated Lights-Out Network Interface Controller Total Receive Error Packets.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cpqSm2NicRecvUnknownPackets 1.3.6.1.4.1.232.9.2.5.2.1.15
Remote Insight/ Integrated Lights-Out Network Interface Controller Number of Unknown Protocol Packets.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Counter  

cpqSm2ServerReset 9001
Server Reset Detected. The Remote Insight/ Integrated Lights-Out firmware has detected a server reset.
TRAP-TYPE    

cpqSm2ServerPowerOutage 9002
Server Power Outage. The Remote Insight/ Integrated Lights-Out firmware has detected server power failure.
TRAP-TYPE    

cpqSm2UnauthorizedLoginAttempts 9003
Remote Insight/ Integrated Lights-Out Unauthorized Login Attempts. The Remote Insight/ Integrated Lights-Out firmware has detected unauthorized login attempts.
TRAP-TYPE    

cpqSm2BatteryFailed 9004
Remote Insight Battery Failed. The Remote Insight battery has failed and needs to be replaced.
TRAP-TYPE    

cpqSm2SelfTestError 9005
Remote Insight/ Integrated Lights-Out Self Test Error. The Remote Insight/ Integrated Lights-Out firmware has detected a Remote Insight self test error.
TRAP-TYPE    

cpqSm2InterfaceError 9006
Remote Insight/ Integrated Lights-Out Interface Error. The host OS has detected an error in the Remote Insight/ Integrated Lights-Out interface. The firmware is not responding.
TRAP-TYPE    

cpqSm2BatteryDisconnected 9007
Remote Insight Battery Disconnected. The Remote Insight battery cable has been disconnected.
TRAP-TYPE    

cpqSm2KeyboardCableDisconnected 9008
Keyboard Cable Disconnected. The Remote Insight keyboard cable has been disconnected.
TRAP-TYPE    

cpqSm2MouseCableDisconnected 9009
Mouse Cable Disconnected. The Remote Insight mouse cable has been disconnected.
TRAP-TYPE    

cpqSm2ExternalPowerCableDisconnected 9010
External Power Cable Disconnected. The Remote Insight external power cable has been disconnected.
TRAP-TYPE    

cpqSm2LogsFull 9011
Logs Full. The Remote Insight/ Integrated Lights-Out firmware has detected the logs are full.
TRAP-TYPE    

cpqSm2SecurityOverrideEngaged 9012
Security Override Engaged. The Remote Insight/ Integrated Lights-Out firmware has detected the security override jumper has been toggled to the engaged position.
TRAP-TYPE    

cpqSm2SecurityOverrideDisengaged 9013
Security Override Disengaged. The Remote Insight/ Integrated Lights-Out firmware has detected the security override jumper has been toggled to the disengaged position.
TRAP-TYPE    

cpqSm2ServerFatalError 9014
Server Fatal Error Detected. The Remote Insight/ Integrated Lights-Out firmware has detected a server fatal error.
TRAP-TYPE