CPQSINFO-MIB
File:
CPQSINFO-MIB.mib (143122 bytes)
Imported modules
Imported symbols
Defined Types
CpqSiOsCommonModuleEntry |
|
SEQUENCE |
|
|
|
|
cpqSiOsCommonModuleIndex |
INTEGER |
|
|
cpqSiOsCommonModuleName |
DisplayString |
|
|
cpqSiOsCommonModuleVersion |
DisplayString |
|
|
cpqSiOsCommonModuleDate |
OCTET STRING |
|
|
cpqSiOsCommonModulePurpose |
DisplayString |
|
CpqSiVirtualSystemEntry |
|
SEQUENCE |
|
|
|
|
cpqSiVirtualSystemIndex |
INTEGER |
|
|
cpqSiVirtualSystemSerialNumber |
DisplayString |
|
|
cpqSiVirtualSystemUUID |
DisplayString |
|
CpqSiMemModuleEntry |
|
SEQUENCE |
|
|
|
|
cpqSiMemBoardIndex |
INTEGER |
|
|
cpqSiMemModuleIndex |
INTEGER |
|
|
cpqSiMemModuleSize |
INTEGER |
|
|
cpqSiMemModuleType |
INTEGER |
|
|
cpqSiMemModuleSpeed |
INTEGER |
|
|
cpqSiMemModuleTechnology |
INTEGER |
|
|
cpqSiMemModuleManufacturer |
DisplayString |
|
|
cpqSiMemModulePartNo |
DisplayString |
|
|
cpqSiMemModuleDate |
OCTET STRING |
|
|
cpqSiMemModuleSerialNo |
DisplayString |
|
|
cpqSiMemModuleECCStatus |
INTEGER |
|
|
cpqSiMemModuleHwLocation |
DisplayString |
|
|
cpqSiMemModuleFrequency |
INTEGER |
|
|
cpqSiMemModuleCellTablePtr |
INTEGER |
|
|
cpqSiMemModuleCellStatus |
INTEGER |
|
|
cpqSiMemModulePartNoMfgr |
DisplayString |
|
|
cpqSiMemModuleSerialNoMfgr |
DisplayString |
|
CpqSiProcMicroPatchEntry |
|
SEQUENCE |
|
|
|
|
cpqSiProcMicroPatchIndex |
INTEGER |
|
|
cpqSiProcMicroPatchId |
INTEGER |
|
|
cpqSiProcMicroPatchDate |
OCTET STRING |
|
|
cpqSiProcMicroPatchFamily |
OCTET STRING |
|
CpqSiPerfStateEntry |
|
SEQUENCE |
|
|
|
|
cpqSiPerfStateIndex |
INTEGER |
|
|
cpqSiPerfState |
INTEGER |
|
|
cpqSiPerfStateCpuFrequency |
INTEGER |
|
|
cpqSiPerfStateCpuPower |
INTEGER |
|
CpqSiBoardRevEntry |
|
SEQUENCE |
|
|
|
|
cpqSiBoardRevSlotIndex |
INTEGER |
|
|
cpqSiBoardRevIndex |
INTEGER |
|
|
cpqSiBoardRevId |
DisplayString |
|
|
cpqSiBoardRevCur |
DisplayString |
|
|
cpqSiBoardRevPrev |
DisplayString |
|
|
cpqSiBoardRevHwLocation |
DisplayString |
|
CpqSiFirmwareRevEntry |
|
SEQUENCE |
|
|
|
|
cpqSiFirmwareRevIndex |
INTEGER |
|
|
cpqSiFirmwareRevDesc |
DisplayString |
|
|
cpqSiFirmwareRevString |
DisplayString |
|
|
cpqSiFirmwareRevCellTablePtr |
INTEGER |
|
|
cpqSiFirmwareLocation |
DisplayString |
|
|
cpqSiFirmwareStatus |
INTEGER |
|
CpqSiFirmwareCfgEntry |
|
SEQUENCE |
|
|
|
|
cpqSiFirmwareCfgName |
DisplayString |
|
|
cpqSiFirmwareCfgValue |
DisplayString |
|
CpqSiMonitorEntry |
|
SEQUENCE |
|
|
|
|
cpqSiMonitorIndex |
INTEGER |
|
|
cpqSiMonitorEdidRaw |
OCTET STRING |
|
|
cpqSiMonitorDesc |
DisplayString |
|
|
cpqSiMonitorSerialNumber |
DisplayString |
|
|
cpqSiMonitorManufactureDate |
OCTET STRING |
|
|
cpqSiMonitorHeight |
INTEGER |
|
|
cpqSiMonitorWidth |
INTEGER |
|
|
cpqSiMonitorMaxHorPixel |
INTEGER |
|
|
cpqSiMonitorMaxVertPixel |
INTEGER |
|
|
cpqSiMonitorMaxRefreshRate |
INTEGER |
|
|
cpqSiMonitorManufacturer |
DisplayString |
|
|
cpqSiMonitorThermalCondition |
INTEGER |
|
|
cpqSiMonitorOperationalCondition |
INTEGER |
|
|
cpqSiMonitorStatus |
INTEGER |
|
CpqSiHotPlugSlotEntry |
|
SEQUENCE |
|
|
|
|
cpqSiHotPlugSlotChassis |
INTEGER |
|
|
cpqSiHotPlugSlotIndex |
INTEGER |
|
|
cpqSiHotPlugSlotBoardPresent |
INTEGER |
|
|
cpqSiHotPlugSlotPowerState |
INTEGER |
|
|
cpqSiHotPlugSlotBoardCondition |
INTEGER |
|
|
cpqSiHotPlugSlotErrorStatus |
INTEGER |
|
|
cpqSiHotPlugSlotHwLocation |
DisplayString |
|
CpqSiSysBatteryEntry |
|
SEQUENCE |
|
|
|
|
cpqSiSysBatteryIndex |
INTEGER |
|
|
cpqSiSysBatteryModel |
DisplayString |
|
|
cpqSiSysBatterySerialNum |
DisplayString |
|
|
cpqSiSysBatteryAssetTag |
DisplayString |
|
|
cpqSiSysBatteryManufacturer |
DisplayString |
|
|
cpqSiSysBatteryDate |
OCTET STRING |
|
|
cpqSiSysBatterySmartVersion |
DisplayString |
|
|
cpqSiSysBatteryCondition |
INTEGER |
|
|
cpqSiSysBatteryStatus |
INTEGER |
|
|
cpqSiSysBatteryChemistry |
INTEGER |
|
|
cpqSiSysBatteryRemainingCap |
INTEGER |
|
|
cpqSiSysBatteryFirmwareRevision |
INTEGER |
|
|
cpqSiSysBatteryHardwareRevision |
INTEGER |
|
|
cpqSiSysBatteryFullCap |
INTEGER |
|
|
cpqSiSysBatteryDesignCap |
INTEGER |
|
|
cpqSiSysBatteryHwLocation |
DisplayString |
|
CpqSiFruEntry |
|
SEQUENCE |
|
|
|
|
cpqSiFruIndex |
INTEGER |
|
|
cpqSiFruType |
INTEGER |
|
|
cpqSiFruDescr |
DisplayString |
|
|
cpqSiFruVendor |
DisplayString |
|
|
cpqSiFruPartNumber |
DisplayString |
|
|
cpqSiFruRevision |
DisplayString |
|
|
cpqSiFruFirmwareRevision |
DisplayString |
|
|
cpqSiFruSerialNumber |
DisplayString |
|
|
cpqSiFruAssetNo |
DisplayString |
|
|
cpqSiFruClass |
INTEGER |
|
|
cpqSiFruSlotNumber |
DisplayString |
|
|
cpqSiFruSubAssemblyNumber |
INTEGER |
|
|
cpqSiFruAssemblyNumber |
INTEGER |
|
|
cpqSiFruChassisNumber |
INTEGER |
|
|
cpqSiFruPositionNumber |
INTEGER |
|
|
cpqSiFruCabinetIDNumber |
INTEGER |
|
|
cpqSiFruSiteLocation |
INTEGER |
|
|
cpqSiFruDiagStatus |
INTEGER |
|
|
cpqSiFruExtendedDiagStatus |
INTEGER |
|
|
cpqSiFruCellTablePtr |
INTEGER |
|
|
cpqSiFruIOCTablePtr |
INTEGER |
|
|
cpqSiFruFileId |
DisplayString |
|
|
cpqSiFruScanRev |
DisplayString |
|
CpqSiRackEnclosureMgrEntry |
|
SEQUENCE |
|
|
|
|
cpqSiRackEnclosureMgrIndex |
INTEGER |
|
|
cpqSiRackEnclosureMgrType |
INTEGER |
|
|
cpqSiRackEnclosureMgrIpAddr |
DisplayString |
|
|
cpqSiRackEnclosureMgrWebLink |
DisplayString |
|
|
cpqSiRackEnclosureMgrCondition |
INTEGER |
|
|
cpqSiRackEnclosureMgrSerialNumber |
DisplayString |
|
|
cpqSiRackEnclosureMgrModel |
DisplayString |
|
|
cpqSiRackEnclosureMgrName |
DisplayString |
|
|
cpqSiRackEnclosureMgrFwRev |
DisplayString |
|
|
cpqSiRackEnclosureMgrProductID |
DisplayString |
|
|
cpqSiRackEnclosureMgrUUID |
DisplayString |
|
Defined Values
cpqSiAsset |
1.3.6.1.4.1.232.2.2.2 |
OBJECT IDENTIFIER |
|
|
|
cpqSiVideo |
1.3.6.1.4.1.232.2.2.7 |
OBJECT IDENTIFIER |
|
|
|
cpqSiFru |
1.3.6.1.4.1.232.2.2.12 |
OBJECT IDENTIFIER |
|
|
|
cpqSiRack |
1.3.6.1.4.1.232.2.2.15 |
OBJECT IDENTIFIER |
|
|
|
cpqSiMP |
1.3.6.1.4.1.232.2.2.16 |
OBJECT IDENTIFIER |
|
|
|
cpqSiMibRevMajor |
1.3.6.1.4.1.232.2.1.1 |
The major revision level of the MIB.
A change in the major revision level represents a major change
in the architecture of the MIB. A change in the major revision
level may indicate a significant change in the information
supported and/or the meaning of the supported information,
correct interpretation of data may require a MIB document with
the same major revision level. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
1..65535 |
|
cpqSiMibRevMinor |
1.3.6.1.4.1.232.2.1.2 |
The minor revision level of the MIB.
A change in the minor revision level may represent some minor
additional support, no changes to any pre-existing information
has occurred. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65535 |
|
cpqSiMibCondition |
1.3.6.1.4.1.232.2.1.3 |
The overall condition.
This object represents the overall status of the server
information represented by this MIB. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
other(1), ok(2), degraded(3), failed(4) |
|
cpqSiOsCommonPollFreq |
1.3.6.1.4.1.232.2.2.1.4.1 |
The Insight Agent's polling frequency.
The frequency, in seconds, at which the Insight Agent requests
information from the device driver. A frequency of zero (0)
indicates that the Insight Agent retrieves the information upon
request of a management station, it does not poll the device
driver at a specific interval.
If the poll frequency is zero (0) all attempts to write to this
object will fail. If the poll frequency is non-zero,
setting this value will change the polling frequency of the
Insight Agent. Setting the poll frequency to zero (0) will
always fail, an agent may also choose to fail any request to
change the poll frequency to a value that would severely impact
system performance. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65535 |
|
cpqSiOsCommonModuleEntry |
1.3.6.1.4.1.232.2.2.1.4.2.1 |
A description of a software module that provides an interface
to the device this MIB describes. |
Status: deprecated |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
CpqSiOsCommonModuleEntry |
|
|
cpqSiOsCommonModuleIndex |
1.3.6.1.4.1.232.2.2.1.4.2.1.1 |
A unique index for this module description. |
Status: deprecated |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..255 |
|
cpqSiOsCommonModuleVersion |
1.3.6.1.4.1.232.2.2.1.4.2.1.3 |
The module version in XX.YY format.
Where XX is the major version number and YY is the minor version
number. This field will be a null (size 0) string if the agent
cannot provide the module version. |
Status: deprecated |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..5) |
|
cpqSiOsCommonModuleDate |
1.3.6.1.4.1.232.2.2.1.4.2.1.4 |
The module date.
field octets contents range
===== ====== ======= =====
1 1-2 year 0..65536
2 3 month 1..12
3 4 day 1..31
4 5 hour 0..23
5 6 minute 0..59
6 7 second 0..60
(use 60 for leap-second)
This field will be set to year = 0 if the agent cannot provide
the module date. The hour, minute, and second field will be set
to zero (0) if they are not relevant. The year field is set
with the most significant octet first. |
Status: deprecated |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(7) |
|
cpqSiSysSerialNum |
1.3.6.1.4.1.232.2.2.2.1 |
The serial number of the physical system unit.
The string will be empty if the system does not report the
serial number function. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..255) |
|
cpqSiAssetTag |
1.3.6.1.4.1.232.2.2.2.3 |
The customer changeable identifier that is set to the system
serial number at the time of manufacture.
The string will be empty if the system does not report this
function. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..255) |
|
cpqSiOwnershipTag |
1.3.6.1.4.1.232.2.2.2.4 |
This is a customer changeable identifier that will be
displayed by ROM at POST. This is an 80 byte standard
ASCII character string and is Administrator Password
protected.
An example could be:
Property of Hewlett-Packard Company
The string should be NULL terminated. This item will be
empty if the system does not report this function. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..79) |
|
cpqSiSysServiceNum |
1.3.6.1.4.1.232.2.2.2.5 |
The service number of the system unit.
The string will be empty if the system does not report the
system service number. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..255) |
|
cpqSiSysProductId |
1.3.6.1.4.1.232.2.2.2.6 |
The product id string of the system unit.
The string will be empty if the system does not report the
product id. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..255) |
|
cpqSiAssetTagMaxLength |
1.3.6.1.4.1.232.2.2.2.7 |
Maximum allowed size in bytes of the asset tag. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
cpqSiVirtualSystemEntry |
1.3.6.1.4.1.232.2.2.2.8.1 |
A virtual system information table entry. |
Status: optional |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
CpqSiVirtualSystemEntry |
|
|
cpqSiVirtualSystemIndex |
1.3.6.1.4.1.232.2.2.2.8.1.1 |
The unique index of the virtual system information entry. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..255 |
|
cpqSiVirtualSystemSerialNumber |
1.3.6.1.4.1.232.2.2.2.8.1.2 |
The HP Virtual Serial Number for the computer system package. The Virtual
Serial Number is the system serial number exposed to the operating
system when running in an HP Virtual Connect environment. The Virtual
Serial Number presented here will correspond to the Virtual UUID at the
same index location. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
cpqSiVirtualSystemUUID |
1.3.6.1.4.1.232.2.2.2.8.1.3 |
The HP Virtual UUID for the computer system package. The Virtual
UUID is the UUID number exposed to the operating system when running
in an HP Virtual Connect environment. The Virtual UUID presented
here will correspond to the Virtual serial number at the same index
location. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
cpqSiPowerOnPassword |
1.3.6.1.4.1.232.2.2.3.1 |
The state of the power on password feature. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
other(1), disabled(2), enabled(3) |
|
cpqSiNetServerMode |
1.3.6.1.4.1.232.2.2.3.2 |
The state of the network server mode feature. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
other(1), disabled(2), enabled(3) |
|
cpqSiQuickLockPassword |
1.3.6.1.4.1.232.2.2.3.3 |
The state of the quicklock password feature. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
other(1), disabled(2), enabled(3) |
|
cpqSiQuickBlank |
1.3.6.1.4.1.232.2.2.3.4 |
The state of the quick blank screen feature. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
other(1), disabled(2), enabled(3) |
|
cpqSiDisketteBootControl |
1.3.6.1.4.1.232.2.2.3.5 |
The state of the diskette boot control feature. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
other(1), disabled(2), enabled(3) |
|
cpqSiSerialPortAControl |
1.3.6.1.4.1.232.2.2.3.6 |
The state of the access control for the primary serial port
interface embedded in the system board. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
other(1), disabled(2), enabled(3) |
|
cpqSiSerialPortBControl |
1.3.6.1.4.1.232.2.2.3.7 |
The state of the access control for the secondary serial port
interface embedded in the system board. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
other(1), disabled(2), enabled(3) |
|
cpqSiParallelPortControl |
1.3.6.1.4.1.232.2.2.3.8 |
The state of the access control for the parallel port interface
embedded in the system board. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
other(1), disabled(2), enabled(3) |
|
cpqSiFloppyDiskControl |
1.3.6.1.4.1.232.2.2.3.9 |
The state of the access control for the floppy diskette
interface embedded in the system board. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
other(1), disabled(2), enabled(3) |
|
cpqSiFixedDiskControl |
1.3.6.1.4.1.232.2.2.3.10 |
The state of the access control for the fixed disk interface
embedded in the system board. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
other(1), disabled(2), enabled(3) |
|
cpqSiHoodRemovedTime |
1.3.6.1.4.1.232.2.2.3.11 |
Last detection of hood removed by Smart Hood Sensor. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..255) |
|
cpqSiHoodSensorConfiguration |
1.3.6.1.4.1.232.2.2.3.12 |
This is the current configuration of the Smart Cover
sensor.
The following values are currently defined:
other(1)
Smart Cover sensor is not supported on this system or cannot
be determined by the Insight Agent. You may need to upgrade
your software.
disabled(2)
Smart Cover sensor will not detect a hood removal and
cpqSiHoodRemovedTime will not be updated.
notifyUser(3)
Smart Cover sensor will detect a hood removal and will display
a message at POST for the user.
adminPasswordProtected(4)
Smart Cover sensor will detect a hood removal and will display
a message at POST for the user to enter the Admin Password.
The system will not boot until proper password is entered. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
other(1), disabled(2), notifyUser(3), adminPasswordProtected(4) |
|
cpqSiSmartCoverLockStatus |
1.3.6.1.4.1.232.2.2.3.13 |
This is the current status of the Smart Cover
Lock. The following values are currently defined:
other(1)
Smart Cover Lock is not supported on this system or cannot
be determined by the Insight Agent. You may need to upgrade
your software.
unlocked(2)
Smart Cover Lock is not locked. The status will be set to
unlocked due to one of the following:
1. The system hood is removed, or
2. There is no administrator password set, or
3. The administrator manually sets status to unlock.
locked(3)
Smart Cover Lock is locked. The administrator password is
required to unlock the hood. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
other(1), unlocked(2), locked(3) |
|
cpqSiUSBPortControl |
1.3.6.1.4.1.232.2.2.3.14 |
The state of the access control for the Universal
Serial Bus interface(s) embedded in the system
board.
other(1)
If Status could not be determined.
disabled(2)
USB interface is disable.
enabled(3)
USB interface is enable.
legacydisabled(4)
Legacy USB interface is disabled.
externalportdisabled(5)
External USB Ports are disabled. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
other(1), disabled(2), enabled(3), legacydisabled(4), externalportdisabled(5) |
|
cpqSiProductId |
1.3.6.1.4.1.232.2.2.4.1 |
The machine product ID.
This value indicates the product type of the system board
in this system. The value 127 will be given if the machine ID
cannot be determined. A value of 127 will also be used for the
special case of a machine containing neither EISA nor ISA slots. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
1..65535 |
|
cpqSiProductName |
1.3.6.1.4.1.232.2.2.4.2 |
The machine product name.
The name of the machine used in this system. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..255) |
|
cpqSiMemModuleEntry |
1.3.6.1.4.1.232.2.2.4.5.1 |
A memory module description. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
CpqSiMemModuleEntry |
|
|
cpqSiMemBoardIndex |
1.3.6.1.4.1.232.2.2.4.5.1.1 |
The slot in which the memory board or cartridge is installed.
A value of 0 indicates memory installed directly on the
system board. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..255 |
|
cpqSiMemModuleIndex |
1.3.6.1.4.1.232.2.2.4.5.1.2 |
The memory module number. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65535 |
|
cpqSiMemModuleSize |
1.3.6.1.4.1.232.2.2.4.5.1.3 |
Module memory size in kilobytes. A kilobyte of memory is
defined as 1024 bytes.
A size of 0 indicates the module is not present. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..2147483647 |
|
cpqSiMemModuleType |
1.3.6.1.4.1.232.2.2.4.5.1.4 |
Type of memory module installed. The value other(1) will be
given if the type is not known. The value board(2) will be
given if the memory module is permanently mounted (not modular)
on a system board or memory expansion board. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
other(1), board(2), cpqSingleWidthModule(3), cpqDoubleWidthModule(4), simm(5), pcmcia(6), compaq-specific(7), dimm(8), smallOutlineDimm(9), rimm(10), srimm(11), fb-dimm(12) |
|
cpqSiMemModuleSpeed |
1.3.6.1.4.1.232.2.2.4.5.1.5 |
Module memory speed in nanoseconds. The value zero (0) will
be given if the module speed cannot be determined. |
Status: deprecated |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65535 |
|
cpqSiMemModuleTechnology |
1.3.6.1.4.1.232.2.2.4.5.1.6 |
Technology type of memory module installed. The value other(1)
will be given if the technology is not known. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
other(1), fastPageMode(2), edoPageMode(3), burstEdoPageMode(4), synchronous(5), rdram(6) |
|
cpqSiMemModuleManufacturer |
1.3.6.1.4.1.232.2.2.4.5.1.7 |
The memory module's manufacturer name.
This field will be a null (size 0) string if the manufacturer
name is not available. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..255) |
|
cpqSiMemModulePartNo |
1.3.6.1.4.1.232.2.2.4.5.1.8 |
The memory module's manufacturer part number.
This field will be a null (size 0) string if the manufacturer
part number is not available. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..255) |
|
cpqSiMemModuleDate |
1.3.6.1.4.1.232.2.2.4.5.1.9 |
The memory module date of manufacture.
field octets contents range
===== ====== ====================== ========
1 1-2 year 0..65536
2 3 month 1..12
3 4 day 1..31
4 5 hour 0..23
5 6 minute 0..59
6 7 second 0..60
(use 60 for leap-second)
This field will be set to year = 0 if the date of manufacture
is not available. The hour, minute, and second fields will
always be set to 0. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(7) |
|
cpqSiMemModuleSerialNo |
1.3.6.1.4.1.232.2.2.4.5.1.10 |
The memory module's serial number.
This field will be a null (size 0) string if the serial number
is not available. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..255) |
|
cpqSiMemModuleECCStatus |
1.3.6.1.4.1.232.2.2.4.5.1.11 |
This provides the current status of the correctable memory
errors for this memory module.
The following status values are supported:
other(1):
ECC is not supported on this memory module.
ok(2):
The correctable error count is below threshold.
degraded(3):
The correctable error count has exceeded threshold.
degradedModuleIndexUnknown(4):
The correctable error count has exceeded threshold.
The module index not available. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
other(1), ok(2), degraded(3), degradedModuleIndexUnknown(4) |
|
cpqSiMemModuleHwLocation |
1.3.6.1.4.1.232.2.2.4.5.1.12 |
A text description of the hardware location, on complex
multi SBB hardware only, for the memory module.
A NULL string indicates that the hardware location could not
be determined or is irrelevant. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..255) |
|
cpqSiMemModuleFrequency |
1.3.6.1.4.1.232.2.2.4.5.1.13 |
The memory module frequency in MHz. The value zero (0) will
be given if the module frequency cannot be determined. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65535 |
|
cpqSiMemModuleCellTablePtr |
1.3.6.1.4.1.232.2.2.4.5.1.14 |
Index for the cell in cpqSeCellTable where the memory board is
installed. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..15 |
|
cpqSiMemModuleCellStatus |
1.3.6.1.4.1.232.2.2.4.5.1.15 |
This provides the current status for this memory module.
The following status values are supported:
other(1):
The memory module status is not available
ok(2):
The memory module is active
deconfigured(3):
The memory module is not ready |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
other(1), ok(2), deconfigured(3) |
|
cpqSiMemModulePartNoMfgr |
1.3.6.1.4.1.232.2.2.4.5.1.16 |
The memory module's manufacturer's part number.
This field will be a null (size 0) string if the manufacturer
part number is not available. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..255) |
|
cpqSiMemModuleSerialNoMfgr |
1.3.6.1.4.1.232.2.2.4.5.1.17 |
The memory module's manufacturer's serial number.
This field will be a null (size 0) string if the manufacturer
serial number is not available. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..255) |
|
cpqSiSystemId |
1.3.6.1.4.1.232.2.2.4.6 |
The System ID.
This value indicates the system ID of the system board
in this system. This ID replaces the product ID used in
older machines (cpqSiProductId). A value of 7Eh for the
cpqSiProductId indicates that the cpqSiSystemId should be
used to identify the system. A value of zero (0)
indicates that the system ID function is not supported on this
machine. In this case, the cpqSiProductId should be used to
identify the system. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65535 |
|
cpqSiSystemCpuId |
1.3.6.1.4.1.232.2.2.4.7 |
The System ID : CPU Component.
This value indicates the CPU type of the system board
in this system. A value of zero (0) indicates that the CPU
type cannot be determined. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65535 |
|
cpqSiFlashRomSupport |
1.3.6.1.4.1.232.2.2.4.8 |
This value indicates if this system supports flash upgradable
system ROM. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
other(1), notSupported(2), supported(3) |
|
cpqSiQuickTestRomDate |
1.3.6.1.4.1.232.2.2.4.9 |
This value indicates the date of the current quick test ROM
image.
field octets contents range
===== ====== ======= =====
1 1-2 year 0..65536
2 3 month 1..12
3 4 day 1..31
4 5 hour 0..23
5 6 minute 0..59
6 7 second 0..60
(use 60 for leap-second)
This field will be set to year = 0 if quick test ROM is not
present. The hour, minute, and second field will be set
to zero (0) if they are not relevant. The year field is set
with the most significant octet first. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(7) |
|
cpqSiReboot |
1.3.6.1.4.1.232.2.2.4.10 |
This object may contain the following values:
notAvailable(1)
the system does not support the reboot functionality.
Setting this object to notAvailable(1) has no effect.
available(2)
the system supports the both reboot to functionalities.
Setting this object to available(2) has no effect.
defaultOnlyAvailable(3)
the system supports the only the default reboot functionality.
Setting this object to available(3) has no effect.
rebootToCpqUtils(2693)
the system will reboot to the System Utilities if
the reboot functionality is available. If possible,
the agent will attempt to gracefully shutdown the
operating system before performing the reboot.
If this functionality is unavailable on this system
then all sets will have no effect.
rebootToDefault(8115)
the system will reboot and allow the default boot
process to occur if the reboot functionality is
available. If possible, the agent will attempt to
gracefully shutdown the operating system before
performing the reboot. If this functionality is
unavailable on this system then all sets will have
no effect.
autoShutdown(9037)
If possible, the agent will attempt to gracefully
shutdown the operating system. The agent will not
preform a reboot.
|
Status: deprecated |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
notAvailable(1), available(2), defaultOnlyAvailable(3), rebootToCpqUtils(2693), rebootToDefault(8115), autoShutdown(9037) |
|
cpqSiProcMicroPatchTable |
1.3.6.1.4.1.232.2.2.4.11 |
This table lists the set of processor microcode patches that
the system ROM contains. During post, the ROM will apply the
appropriate patches to the CPU microcode. Scan this table to
ensure that a patch is being applied to a processor. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
CpqSiProcMicroPatchEntry |
|
cpqSiProcMicroPatchEntry |
1.3.6.1.4.1.232.2.2.4.11.1 |
An entry describing one microcode patch contained in the system
ROM. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
CpqSiProcMicroPatchEntry |
|
|
cpqSiProcMicroPatchIndex |
1.3.6.1.4.1.232.2.2.4.11.1.1 |
Index into the microcode patch table. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
1..255 |
|
cpqSiProcMicroPatchId |
1.3.6.1.4.1.232.2.2.4.11.1.2 |
The ID of this particular CPU microcode patch. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
cpqSiProcMicroPatchDate |
1.3.6.1.4.1.232.2.2.4.11.1.3 |
This value indicates the date of this CPU microcode patch.
field octets contents range
===== ====== ======= =====
1 1-2 year 0..65536
2 3 month 1..12
3 4 day 1..31
4 5 hour 0..23
5 6 minute 0..59
6 7 second 0..60
(use 60 for leap-second)
NOTE: Year is stored in packed BCD. The most significant
part is in the second octet. For example:
1995 would be stored as 0x95 0x19.
The hour, minute, and second field will be set to zero (0)
if they are not relevant. The year field is set with the
most significant octet first. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(7) |
|
cpqSiProcMicroPatchFamily |
1.3.6.1.4.1.232.2.2.4.11.1.4 |
The valid family/model/step of the processor that this CPU
microcode patch applies to.
field octets contents range
===== ====== ======= =====
1 1 CPU Step 0..255
2 2 CPU Model 0..255
3 3 CPU Family 0..255 |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(3) |
|
cpqSiPowerMgmtStatus |
1.3.6.1.4.1.232.2.2.4.12 |
The state of power management. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
other(1), disabled(2), enabled(3) |
|
cpqSiRebootFlags |
1.3.6.1.4.1.232.2.2.4.13 |
The Reboot Flags.
This is a collection of flags used to indicate the re-boot
options available. This integer is a bitmap, with each bit
indicating the availability of an option. If the bit is set
to 1, the option is available; otherwise it is not. Multiple
options are allowed.
NOTE: bit 31 is the most significant bit, bit 0 is the least
significant.
Status This is a collection of flags. Each bit has the
following meaning when it is on (1):
Bit 31: Execute Set
Bit 30-6: RESERVED
Bit 5: Boot to ROM Based Setup
Bit 4: RESERVED
Bit 3: Boot to OS
Bit 2: Boot to Utils
Bit 1: Warm Boot
Bit 0: Cold Boot |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
cpqSiMemErrorIndex |
1.3.6.1.4.1.232.2.2.4.14 |
Placeholder for memory module number for ECC traps.
Represents the number of the memory module for which an ECC status
change has occurred. Set to 65535 if module number not available. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65535 |
|
cpqSiMemECCCondition |
1.3.6.1.4.1.232.2.2.4.15 |
This provides the current condition of the correctable memory
errors for the entire memory.
The following status values are supported:
other(1) :
ECC is not supported.
ok(2) :
The correctable error count is below threshold.
degraded(3) :
The correctable error count has exceeded threshold. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
other(1), ok(2), degraded(3) |
|
cpqSiServerSystemId |
1.3.6.1.4.1.232.2.2.4.17 |
A Server System ID.
This value is used to uniquely identify systems via a unique
ID on systems that do not support the EISA bus. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..8) |
|
cpqSiPowerScheme |
1.3.6.1.4.1.232.2.2.4.18 |
The current active power plan or power scheme of the system. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
unsupported(1), other(2), power-saver(3), balanced(4), high-performance(5), user-defined(6) |
|
cpqSiPowerSchemeName |
1.3.6.1.4.1.232.2.2.4.19 |
The name of current active power plan or power scheme of the
system. When cpqSiPowerScheme has a value of user-defined(6), the
user defined name can be populated here. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..255) |
|
cpqSiPerfStateEntry |
1.3.6.1.4.1.232.2.2.4.23.1 |
An entry describing a supported performance state of the system. |
Status: optional |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
CpqSiPerfStateEntry |
|
|
cpqSiPerfStateIndex |
1.3.6.1.4.1.232.2.2.4.23.1.1 |
Index into the performance state table. cpqSiCurrentPerformanceStatePointer should point to one of these values. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65535 |
|
cpqSiPerfState |
1.3.6.1.4.1.232.2.2.4.23.1.2 |
Performance state number. A unique number assigned to a performance state instance. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65535 |
|
cpqSiPerfStateCpuFrequency |
1.3.6.1.4.1.232.2.2.4.23.1.3 |
The processor frequency in megahertz for this performance state instance. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..2147483647 |
|
cpqSiPerfStateCpuPower |
1.3.6.1.4.1.232.2.2.4.23.1.4 |
The processor power setting in milliwatts for this performance state instance. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..2147483647 |
|
cpqSiTPMmodule |
1.3.6.1.4.1.232.2.2.4.24 |
This field will be populated if TPM module is present in the system board.
other(1)
No record of TPM exist.
absent(2)
TPM module is not present in the system.
presentEnabled(3)
TPM module is present in the system and currently enabled.
presentDisabled(4)
TPM module is present in the system and currently not enabled. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
other(1), absent(2), presentEnabled(3), presentDisabled(4) |
|
cpqSiCurRevDate |
1.3.6.1.4.1.232.2.2.5.1 |
The current board revision configuration date in MM/DD/YY
format. This is the date that the EISA Configuration Utility
was used to define the current configuration. This value will
contain 'N/A' if this system does not support this feature. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(8) |
|
cpqSiPrevRevDate |
1.3.6.1.4.1.232.2.2.5.2 |
The previous board revision configuration date in MM/DD/YY
format. This is the date that the EISA Configuration Utility
was used to define the previous configuration. This value will
contain 'N/A' if this system does not support this feature. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(8) |
|
cpqSiBoardRevEntry |
1.3.6.1.4.1.232.2.2.5.3.1 |
A board revision description. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
CpqSiBoardRevEntry |
|
|
cpqSiBoardRevSlotIndex |
1.3.6.1.4.1.232.2.2.5.3.1.1 |
The slot in which the board described in this entry resides.
Zero (0) indicates the system board. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..255 |
|
cpqSiBoardRevIndex |
1.3.6.1.4.1.232.2.2.5.3.1.2 |
A number that uniquely specifies which board in a specific slot
is described in this entry. Zero (0) indicates the main board
in this slot. Any other number indicates a daughter board or a
component of the main board. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65535 |
|
cpqSiBoardRevId |
1.3.6.1.4.1.232.2.2.5.3.1.3 |
A description of the board type. The defined types are:
Type
==============
System Board
Processor n (n = the processor number)
Memory n (n = the memory board number)
Slot n (n = the slot the board occupies)
Other types may be defined at a later date. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..16) |
|
cpqSiBoardRevCur |
1.3.6.1.4.1.232.2.2.5.3.1.4 |
The current revision for the board described in this entry.
This value will be N/A if there is no current revision
information. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..8) |
|
cpqSiBoardRevPrev |
1.3.6.1.4.1.232.2.2.5.3.1.5 |
The revision for the board described in this entry prior to the
current configuration. This value will be N/A if there is no
previous revision information. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..8) |
|
cpqSiBoardRevHwLocation |
1.3.6.1.4.1.232.2.2.5.3.1.6 |
A text description of the hardware location, on complex
multi SBB hardware only, for the board.
A NULL string indicates that the hardware location could not
be determined or is irrelevant. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..255) |
|
cpqSiFirmwareRevEntry |
1.3.6.1.4.1.232.2.2.5.4.1 |
A firmware revision description. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
CpqSiFirmwareRevEntry |
|
|
cpqSiFirmwareRevIndex |
1.3.6.1.4.1.232.2.2.5.4.1.1 |
Locally-unique index for this entry. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
cpqSiFirmwareRevDesc |
1.3.6.1.4.1.232.2.2.5.4.1.2 |
Description, e.g. SRM console, ARC console, System BIOS, etc. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
cpqSiFirmwareRevCellTablePtr |
1.3.6.1.4.1.232.2.2.5.4.1.4 |
Index for the cell in cpqSeCellTable where this firmware is located |
Status: deprecated |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
cpqSiFirmwareLocation |
1.3.6.1.4.1.232.2.2.5.4.1.5 |
Description of which board the firmware is located in. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..255) |
|
cpqSiFirmwareStatus |
1.3.6.1.4.1.232.2.2.5.4.1.6 |
The current status for this firmware. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
unknown(1), active(2), inactive(3) |
|
cpqSiFirmwareCfgTable |
1.3.6.1.4.1.232.2.2.5.5 |
Table of soft switches and symbols maintained by the
firmware. May be operating system and/or option-specific
and will certainly be system-specific. This list is
intended to be easily extensible and support arbitrary
datatypes. It includes such switches as powerup options,
default dump device, etc.
Note - the string comparison for svrFwSymbolName is case
insensitive. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
CpqSiFirmwareCfgEntry |
|
cpqSiFirmwareCfgEntry |
1.3.6.1.4.1.232.2.2.5.5.1 |
Each entry represents one variable or symbol maintained by
or stored by some instance of firmware in the system. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
CpqSiFirmwareCfgEntry |
|
|
cpqSiFirmwareCfgName |
1.3.6.1.4.1.232.2.2.5.5.1.1 |
The firmware configuration symbol name as visible from the
console. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
cpqSiFirmwareCfgValue |
1.3.6.1.4.1.232.2.2.5.5.1.2 |
The firmware configuration symbol value. Null if none
or unknown. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
cpqSiRackServerShutdownRole |
1.3.6.1.4.1.232.2.2.6.1 |
This entry describes this system's role in a rack-mounted
uninterruptible power supply family. The master both
communicates with the UPS and derives its power from the
UPS. The slave derives its power from the UPS, but does
not communicate with it. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
other(1), master(2), slave(3) |
|
cpqSiRackServerMasterName |
1.3.6.1.4.1.232.2.2.6.2 |
This entry describes the name of the master server in a
rack-mounted uninterruptible power supply family. A slave
system would communicate with this server to derive UPS
status. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..48) |
|
cpqSiVideoEdidRaw |
1.3.6.1.4.1.232.2.2.7.1 |
The raw value returned from the video EDID function. |
Status: deprecated |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(128) |
|
cpqSiVideoDesc |
1.3.6.1.4.1.232.2.2.7.2 |
The manufacturer and model description of the video display. |
Status: deprecated |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..255) |
|
cpqSiVideoManufactureDate |
1.3.6.1.4.1.232.2.2.7.4 |
The date of manufacture of the video display in the following
format:
field octets contents range
===== ====== ======= =====
1 1-2 year 0..65536
2 3 month 1..12
3 4 day 1..31
4 5 hour 0..23
5 6 minute 0..59
6 7 second 0..60
(use 60 for leap-second)
This field will be set to year = 0 if the agent cannot provide
the date. The date information that is given resolves to a year
and week, so the hour, minute, and second field will be set to 0,
the month and day fields will give the monday of the week of
manufacture. |
Status: deprecated |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(7) |
|
cpqSiVideoHeight |
1.3.6.1.4.1.232.2.2.7.5 |
The maximum image height of the video display in centimeters |
Status: deprecated |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..255 |
|
cpqSiVideoWidth |
1.3.6.1.4.1.232.2.2.7.6 |
The maximum image width of the video display in centimeters |
Status: deprecated |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..255 |
|
cpqSiVideoMaxHorPixel |
1.3.6.1.4.1.232.2.2.7.7 |
The number of horizontal pixels in the highest resolution video
mode supported. |
Status: deprecated |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65535 |
|
cpqSiVideoMaxVertPixel |
1.3.6.1.4.1.232.2.2.7.8 |
The number of vertical pixels in the highest resolution video
mode supported. |
Status: deprecated |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65535 |
|
cpqSiVideoMaxRefreshRate |
1.3.6.1.4.1.232.2.2.7.9 |
The video refresh rate in Hz of the highest resolution video
mode supported. |
Status: deprecated |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65535 |
|
cpqSiMonitorOverallCondition |
1.3.6.1.4.1.232.2.2.8.1 |
This value specifies the overall condition of the system's
monitor(s).
The following conditions are supported:
other(1)
The monitor does not support fault reporting or condition is
unknown.
ok(2)
The monitor is operating OK.
degraded(3)
The monitor has detected a fault. The monitor is still useable
but action should be taken to return the monitor to ok.
failed(4)
The monitor has detected a fault. The monitor will not
be useable. Action should be taken to replace the monitor. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
other(1), ok(2), degraded(3), failed(4) |
|
cpqSiMonitorTable |
1.3.6.1.4.1.232.2.2.8.2 |
A table of all video monitor descriptions connected to this
system. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
CpqSiMonitorEntry |
|
cpqSiMonitorEntry |
1.3.6.1.4.1.232.2.2.8.2.1 |
A video monitor description. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
CpqSiMonitorEntry |
|
|
cpqSiMonitorIndex |
1.3.6.1.4.1.232.2.2.8.2.1.1 |
A unique index for each video display connected to the system. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..15 |
|
cpqSiMonitorEdidRaw |
1.3.6.1.4.1.232.2.2.8.2.1.2 |
The raw value returned from the video EDID function. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(128) |
|
cpqSiMonitorDesc |
1.3.6.1.4.1.232.2.2.8.2.1.3 |
The manufacturer and model description of the video display. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..255) |
|
cpqSiMonitorManufactureDate |
1.3.6.1.4.1.232.2.2.8.2.1.5 |
The date of manufacture of the video display in the following
format:
field octets contents range
===== ====== ======= =====
1 1-2 year 0..65536
2 3 month 1..12
3 4 day 1..31
4 5 hour 0..23
5 6 minute 0..59
6 7 second 0..60
(use 60 for leap-second)
This field will be set to year = 0 if the agent cannot provide
the date. The date information that is given resolves to a year
and week, so the hour, minute, and second field will be set to 0,
the month and day fields will give the monday of the week of
manufacture. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(7) |
|
cpqSiMonitorHeight |
1.3.6.1.4.1.232.2.2.8.2.1.6 |
The maximum image height of the video display in centimeters |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..255 |
|
cpqSiMonitorWidth |
1.3.6.1.4.1.232.2.2.8.2.1.7 |
The maximum image width of the video display in centimeters |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..255 |
|
cpqSiMonitorMaxHorPixel |
1.3.6.1.4.1.232.2.2.8.2.1.8 |
The number of horizontal pixels in the highest resolution video
mode supported. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65535 |
|
cpqSiMonitorMaxVertPixel |
1.3.6.1.4.1.232.2.2.8.2.1.9 |
The number of vertical pixels in the highest resolution video mode
supported. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65535 |
|
cpqSiMonitorMaxRefreshRate |
1.3.6.1.4.1.232.2.2.8.2.1.10 |
The video refresh rate in Hz of the highest resolution video mode
supported. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65535 |
|
cpqSiMonitorThermalCondition |
1.3.6.1.4.1.232.2.2.8.2.1.12 |
This provides the condition of the monitor's internal temperature.
This value will be one of the following:
other(1)
Monitor thermal fault reporting is not supported by this monitor
or the Insight Agent does not recognize the status. You may
need to upgrade your software.
ok(2)
The internal temperature is within normal limits.
degraded(3)
The internal temperature is outside normal operating range. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
other(1), ok(2), degraded(3) |
|
cpqSiMonitorOperationalCondition |
1.3.6.1.4.1.232.2.2.8.2.1.13 |
This provides the condition of the monitor's operational features.
This condition value will be one of the following:
other(1)
Monitor operational fault reporting is not supported by this
monitor or the Insight Agent does not recognize the status.
You may need to upgrade your software.
ok(2)
The monitor is operating within normal limits.
degraded(3)
The monitor is not functioning within normal operating limits.
At least one of the operational features has become degraded.
failed(4)
The monitor is not functioning within normal operating limits.
At least one of the operational features has failed causing the
monitor to not be usable. The monitor should be replaced. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
other(1), ok(2), degraded(3), failed(4) |
|
cpqSiMonitorStatus |
1.3.6.1.4.1.232.2.2.8.2.1.14 |
This provides the status of the monitor's fault reporting features.
This status value will be one of the following:
other(1)
Monitor fault reporting is not supported by this monitor or the
Insight Agent does not recognize the status. You may need to
upgrade your software.
unknown(2)
The monitor status is unknown because the monitor is
either in power saving mode or it has been turned off.
ok(3)
The monitor is operating within normal limits.
thermalDegraded(4)
The monitor's internal temperature is not functioning within
normal operating limits.
operationalFailure(5)
The monitor is not functioning within normal operating limits.
At least one of the operational features has failed.
The monitor should be replaced. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
other(1), unknown(2), ok(3), thermalDegraded(4), operationalFailure(5) |
|
cpqSiHotPlugSlotSupported |
1.3.6.1.4.1.232.2.2.9.1 |
This value specifies if this system supports the Hot
Pluggable Slot feature. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
other(1), notSupported(2), supported(3) |
|
cpqSiHotPlugSlotCondition |
1.3.6.1.4.1.232.2.2.9.2 |
This value specifies the overall condition of the Hot Plug
Slot feature.
The Hot Plug condition is set as follows:
other(1)
When Hot Plug Slots are not supported or condition is unknown.
ok(2)
If there are no hot plug slots with a condition of degraded
or failed.
degraded(3)
If there are degraded slot entries but none failed.
failed(4)
If there are failed slot entries. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
other(1), ok(2), degraded(3), failed(4) |
|
cpqSiHotPlugSlotChangeCount |
1.3.6.1.4.1.232.2.2.9.3 |
This value will be incremented each time a hot plug event
occurs resulting in a change in the hot plug slot table. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
cpqSiHotPlugSlotEntry |
1.3.6.1.4.1.232.2.2.9.4.1 |
A description of a Hot Plug Slot. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
CpqSiHotPlugSlotEntry |
|
|
cpqSiHotPlugSlotChassis |
1.3.6.1.4.1.232.2.2.9.4.1.1 |
The Chassis where this hot plug slot resides. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..255 |
|
cpqSiHotPlugSlotIndex |
1.3.6.1.4.1.232.2.2.9.4.1.2 |
The slot within the chassis for this hot plug slot. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..255 |
|
cpqSiHotPlugSlotBoardPresent |
1.3.6.1.4.1.232.2.2.9.4.1.3 |
This value indicates whether a board is present(2) in or
absent(3) from the slot. A value of other(1) indicates
the information could not be obtained. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
other(1), present(2), absent(3), presentButSuspended(4) |
|
cpqSiHotPlugSlotPowerState |
1.3.6.1.4.1.232.2.2.9.4.1.4 |
This value is set to powerOn(2) when power is being supplied
to the slot and powerOff(3) when power is not being supplied.
A value of other(1) indicates the information could not be
obtained. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
other(1), powerOn(2), powerOff(3) |
|
cpqSiHotPlugSlotBoardCondition |
1.3.6.1.4.1.232.2.2.9.4.1.5 |
This value specifies the condition of the hot plug slot.
The hot plug condition is set as follows:
other(1)
When the condition could not be determined.
ok(2)
The slot is powered up and operating normally.
degraded(3)
If the board in the slot is not fully functioning.
failed(4)
If the slot is failed for any reason. See the status code
for more information on the failure. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
other(1), ok(2), degraded(3), failed(4) |
|
cpqSiHotPlugSlotErrorStatus |
1.3.6.1.4.1.232.2.2.9.4.1.6 |
This value specifies the status of the hot plug slot.
The hot plug slot status is set as follows:
noError(1)
The slot is operating normally.
generalError(2)
A general error occurred.
wrongRevision(3)
The revision of the replacement adapter was different from
the original adapter.
wrongBoard(4)
The model of the replacement adapter was different from the
original adapter.
cannotConfig(5)
The adapter could not be configured.
powerFault(6)
A power fault occurred for the slot.
unexpectedPowerLoss(7)
Power was unexpectedly lost from the slot.
wrongSpeed(8)
The adapter cannot be run at the current bus speed.
functionlFailure(9)
The adapter is not functioning correctly. This may
be caused by a cabling problem. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
noError(1), generalError(2), wrongRevision(3), wrongBoard(4), cannotConfig(5), powerFault(6), unexpectedPowerLoss(7), wrongSpeed(8), functionalFailure(9) |
|
cpqSiHotPlugSlotHwLocation |
1.3.6.1.4.1.232.2.2.9.4.1.7 |
A text description of the hardware location, on complex
multi SBB hardware only, for the hot plug slot.
A NULL string indicates that the hardware location could not
be determined or is irrelevant. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..255) |
|
cpqSiSystemBatteryOverallCondition |
1.3.6.1.4.1.232.2.2.10.1 |
This value specifies the overall condition of all of the
system batteries.
The following conditions are supported:
other(1)
The system does not use system batteries or the battery
condition is unknown.
ok(2)
All System Batteries are operating OK.
degraded(3)
One or more of the System Batteries has degraded. The
degraded battery will continue to function but should be
replaced.
failed(4)
One of more of the System Batteries has failed. The failed
battery is no longer usable. Action should be taken to replace
the battery. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
other(1), ok(2), degraded(3), failed(4) |
|
cpqSiSysBatteryEntry |
1.3.6.1.4.1.232.2.2.10.2.1 |
A system battery description. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
CpqSiSysBatteryEntry |
|
|
cpqSiSysBatteryIndex |
1.3.6.1.4.1.232.2.2.10.2.1.1 |
A unique index for this battery entry. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65535 |
|
cpqSiSysBatteryAssetTag |
1.3.6.1.4.1.232.2.2.10.2.1.4 |
This is the customer changeable battery identifier that is set
to this system battery's serial number at the time of
manufacture.
The string will be empty if the battery does support
this function. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..255) |
|
cpqSiSysBatteryManufacturer |
1.3.6.1.4.1.232.2.2.10.2.1.5 |
The battery's manufacturer's name.
The string will be empty if the battery does support
this function. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..255) |
|
cpqSiSysBatteryDate |
1.3.6.1.4.1.232.2.2.10.2.1.6 |
The battery's manufacture date.
field octets contents range
===== ====== ======= =====
1 1-2 year 0..65536
2 3 month 1..12
3 4 day 1..31
4 5 hour 0..23
5 6 minute 0..59
6 7 second 0..60
(use 60 for leap-second)
This field will be set to year = 0 if the agent cannot provide
the module date. The hour, minute, and second field will be set
to zero (0) if they are not relevant. The year field is set
with the most significant octet first.
The string will be empty if the battery does support
this function. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(7) |
|
cpqSiSysBatterySmartVersion |
1.3.6.1.4.1.232.2.2.10.2.1.7 |
The Smart Battery Data Specification version number supported by this
battery.
The string will be empty if the system battery does support
this function. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..255) |
|
cpqSiSysBatteryCondition |
1.3.6.1.4.1.232.2.2.10.2.1.8 |
This provides the current condition of this system battery.
The following status values are supported:
other(1)
The battery does not support condition monitoring or
the Insight Agent cannot determine condition.
ok(2)
The battery is operating normally. No user action is
required.
degraded(3)
The battery is degraded. The battery is still usable
but should be replaced.
failed(4)
The battery has failed. The battery is no longer
usable and should be replaced soon. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
other(1), ok(2), degraded(3), failed(4) |
|
cpqSiSysBatteryStatus |
1.3.6.1.4.1.232.2.2.10.2.1.9 |
This provides the current status of the battery.
The following status values are supported:
other(1):
This battery does not support status reporting.
ok(2):
The battery is operating ok.
User Action: No action required.
capacityDegraded(3):
Significant battery degradation has occurred.
The battery can no longer be fully recharged.
User Action:
If using multiple batteries, run the Power
Conservation Utility to identify the battery
location. Contact your System Administrator or
Authorized Reseller to order a replacement
battery.
chargeFault(4):
One or more batteries are not functioning properly.
User Action:
Make sure all batteries are operating in the
recommended temperature range. Check for foreign
objects in the battery slots. Remove and reinsert all
batteries to resume normal battery operation.
Contact your System Administrator or Authorized
Reseller if you are still experiencing problems.
batteryFailure(5):
The battery has failed and must be replaced.
User Action:
Contact your System Administrator or Authorized
Reseller to order a replacement battery. Recycle your
old battery. For proper disposal information, refer
to the documentation that came with your computer. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
other(1), ok(2), capacityDegraded(3), chargeFault(4), batteryFailure(5) |
|
cpqSiSysBatteryChemistry |
1.3.6.1.4.1.232.2.2.10.2.1.10 |
The chemistry of the battery. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
other(1), unknown(2), lead-Acid(3), nickel-Cadmium(4), nickel-Metal-Hydride(5), lithium-Ion(6), zinc-Air(7), lithium-Polymer(8) |
|
cpqSiSysBatteryRemainingCap |
1.3.6.1.4.1.232.2.2.10.2.1.11 |
This is a percentage of the battery's remaining capacity
from its design capacity.
If this attribute is not supported, 65535 is returned. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65535 |
|
cpqSiSysBatteryFirmwareRevision |
1.3.6.1.4.1.232.2.2.10.2.1.12 |
This is the revision level of the firmware on the battery.
If this attribute is not supported, 255 is returned. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..255 |
|
cpqSiSysBatteryHardwareRevision |
1.3.6.1.4.1.232.2.2.10.2.1.13 |
This is the revision level of the hardware on the battery.
If this attribute is not supported, 255 is returned. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..255 |
|
cpqSiSysBatteryFullCap |
1.3.6.1.4.1.232.2.2.10.2.1.14 |
This is the mWatt-Hours of the battery's Full capacity on
the current charge.
If this attribute is not supported, 65535 is returned. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65535 |
|
cpqSiSysBatteryDesignCap |
1.3.6.1.4.1.232.2.2.10.2.1.15 |
This is the mWatt-Hours of the battery's design capacity as
specified by the manufacturer.
If this attribute is not supported, 65535 is returned. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
0..65535 |
|
cpqSiSysBatteryHwLocation |
1.3.6.1.4.1.232.2.2.10.2.1.16 |
A text description of the hardware location, on complex
multi SBB hardware only, for the battery.
A NULL string indicates that the hardware location could not
be determined or is irrelevant. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..255) |
|
cpqSiDockingStationStatus |
1.3.6.1.4.1.232.2.2.11.1 |
This value specifies the connection of the computer
system to a docking station.
The following connection states are supported:
notSupported(1)
This system does not interface to a docking station.
docked(2)
This system is connected to a docking station.
undocked(3)
This system is not connect to a docking station. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
notSupported(1), docked(2), undocked(3) |
|
cpqSiDockingStationSerialNum |
1.3.6.1.4.1.232.2.2.11.2 |
The serial number of the docking station.
The string will be empty if the docking station does not support a
serial or the system does not interface to a docking station. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..255) |
|
cpqSiDockingStationModel |
1.3.6.1.4.1.232.2.2.11.3 |
The model name of the docking station.
The string will be empty if the docking station does not report the
model name or the system does not interface to a docking station. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..255) |
|
cpqSiDockingStationAssetTag |
1.3.6.1.4.1.232.2.2.11.4 |
This is a customer changeable identifier that is set to the docking
station serial number at the time of manufacture.
The string will be empty if the docking station does not report an
asset tag or the system does not interface to a docking station. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..255) |
|
cpqSiFruTable |
1.3.6.1.4.1.232.2.2.12.1 |
Table of Field Replaceable Units of system, providing
inventory and asset control information. This table is
referenced from logical hardware descriptions elsewhere in
the MIB. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
CpqSiFruEntry |
|
cpqSiFruEntry |
1.3.6.1.4.1.232.2.2.12.1.1 |
Each entry represents a Field Replaceable Unit (FRU) of hardware. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
CpqSiFruEntry |
|
|
cpqSiFruIndex |
1.3.6.1.4.1.232.2.2.12.1.1.1 |
A locally-unique index value. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
cpqSiFruType |
1.3.6.1.4.1.232.2.2.12.1.1.2 |
General category of the type of FRU that this is. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
unknown(1), other(2), motherBoard(3), processor(4), memoryCard(5), memoryModule(6), peripheralDevice(7), systemBusBridge(8), powerSupply(9), chassis(10), fan(11), ioCard(12) |
|
cpqSiFruDescr |
1.3.6.1.4.1.232.2.2.12.1.1.3 |
More detailed description of FRU type, if known. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
cpqSiFruRevision |
1.3.6.1.4.1.232.2.2.12.1.1.6 |
Version number of this unit. If artwork level is available, it will
appear as 'Artwork: XXX' following FRU version portion. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
cpqSiFruAssetNo |
1.3.6.1.4.1.232.2.2.12.1.1.9 |
The asset number for this unit. This string may be limited. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
cpqSiFruClass |
1.3.6.1.4.1.232.2.2.12.1.1.10 |
Represents the status category of the unit. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
unknown(1), other(2), currentBoardInSlot(3), priorBoardInSlot(4), parentBoard(5), priorParentBoard(6), priorParentSystem(7) |
|
cpqSiFruSubAssemblyNumber |
1.3.6.1.4.1.232.2.2.12.1.1.12 |
Subassembly containing this FRU. From FRU V5.0. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
cpqSiFruAssemblyNumber |
1.3.6.1.4.1.232.2.2.12.1.1.13 |
Assembly containing this FRU. From FRU V5.0. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
cpqSiFruChassisNumber |
1.3.6.1.4.1.232.2.2.12.1.1.14 |
Chassis containing this FRU. From FRU V5.0. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
cpqSiFruPositionNumber |
1.3.6.1.4.1.232.2.2.12.1.1.15 |
Position in Chassis to help locate FRU. From FRU V5.0. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
cpqSiFruCabinetIDNumber |
1.3.6.1.4.1.232.2.2.12.1.1.16 |
Cabinet number containing this FRU. From FRU V5.0. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
cpqSiFruSiteLocation |
1.3.6.1.4.1.232.2.2.12.1.1.17 |
Site code for system containing this FRU. From FRU V5.0. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
cpqSiFruDiagStatus |
1.3.6.1.4.1.232.2.2.12.1.1.18 |
Use system status values to describe current state of the
FRU. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
unknown(1), ok(2), degraded(3), failed(4), disabled(5) |
|
cpqSiFruExtendedDiagStatus |
1.3.6.1.4.1.232.2.2.12.1.1.19 |
Diagnostic Status value returned by Device Specific
diagnostics. Usually through a diagnostic status register
on the device. See product manual for bit descriptions. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
cpqSiFruCellTablePtr |
1.3.6.1.4.1.232.2.2.12.1.1.20 |
Index for the cell in cpqSeCellTable where this FRU is physically located. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
cpqSiFruIOCTablePtr |
1.3.6.1.4.1.232.2.2.12.1.1.21 |
Index for the I/O Chassis in cpqSeIOCTablePtr where this FRU is physically located |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
cpqSiFruFileId |
1.3.6.1.4.1.232.2.2.12.1.1.22 |
This represents the FRU file identifier |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..255) |
|
cpqSiFruScanRev |
1.3.6.1.4.1.232.2.2.12.1.1.23 |
This represents FRU scan revision |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..255) |
|
cpqSiRackEnclosureMgrEntry |
1.3.6.1.4.1.232.2.2.13.1.1 |
A entry for a rack and/or enclosure based system. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
CpqSiRackEnclosureMgrEntry |
|
|
cpqSiRackEnclosureMgrIndex |
1.3.6.1.4.1.232.2.2.13.1.1.1 |
A locally-unique index value. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
cpqSiRackEnclosureMgrType |
1.3.6.1.4.1.232.2.2.13.1.1.2 |
This value specifies the type of enclosure management.
other(1)
When the type not be determined.
noEnclosureManagement(2)
The server is part of a rack/enclosure managed system, but there
is no dedicated enclosure manager.
enclosureManagement(3)
The server is part of a rack/enclosure managed system with a
dedicated enclosure manager.
onboardAdminManagement(4)
The server is part of a rack/enclosure managed system with a
onboard Administrator. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
other(1), noEnclosureManagement(2), enclosureManagement(3), onboardAdminManagement(4) |
|
cpqSiRackEnclosureMgrIpAddr |
1.3.6.1.4.1.232.2.2.13.1.1.3 |
The IP address of the rack enclosure manager.
The string will be empty if the enclosure does not report the
information or it could not be determined. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
cpqSiRackEnclosureMgrWebLink |
1.3.6.1.4.1.232.2.2.13.1.1.4 |
The web link to the enclosure managers web based management
information for the enclosure.
The string will be empty if the enclosure does not report the
information or it could not be determined. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
cpqSiRackEnclosureMgrCondition |
1.3.6.1.4.1.232.2.2.13.1.1.5 |
The overall condition of the Enclosure. For more detailed
status information, follow the cpqSiEnclosureMgrWebLink through
the Web Management Agent interface.
other(1)
This is the default condition for systems when
cpqSiRackEnclosureMgrType has a value of
noEnclosureManagement(2).
When cpqSiRackEnclosureMgrType has a value of
enclosureManagement(3), this indicates the status of the
enclosure manager could not be determined.
ok(2)
The enclosure manager is in an ok state. Follow the
cpqSiRackEnclosureMgrWebLink link in the Web Management Agents
to manage the enclosure.
degraded(3)
The enclosure manager is in a degraded state. Follow the
cpqSiRackEnclosureMgrWebLink link in the Web Management Agents
to manage the enclosure.
failed(4)
The enclosure manager is in a failed state. Follow the
cpqSiRackEnclosureMgrWebLink link in the Web Management Agents
to manage the enclosure. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
other(1), ok(2), degraded(3), failed(4) |
|
cpqSiRackEnclosureMgrSerialNumber |
1.3.6.1.4.1.232.2.2.13.1.1.6 |
The serial number of the enclosure.
The string will be empty if the enclosure does not report the
information or it could not be determined. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
cpqSiRackEnclosureMgrModel |
1.3.6.1.4.1.232.2.2.13.1.1.7 |
The model name of the enclosure.
The string will be empty if it could not be determined. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
cpqSiRackEnclosureMgrName |
1.3.6.1.4.1.232.2.2.13.1.1.8 |
The name of the enclosure. This name logically groups together the
Blade servers installed in the same enclosure and it is shared
with the other servers in the enclosure.
The string will be empty if it could not be determined. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
cpqSiRackEnclosureMgrFwRev |
1.3.6.1.4.1.232.2.2.13.1.1.9 |
The Firmware revision of the Enclosure Manager/Onboard Administrator.
The string will be empty if it could not be determined. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
cpqSiRackEnclosureMgrUUID |
1.3.6.1.4.1.232.2.2.13.1.1.11 |
The Enclosure unique identifier. The string will be empty
if it could not be determined. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
cpqSiServerBladeEnclosureBayNumber |
1.3.6.1.4.1.232.2.2.14.1 |
This value specifies the enclosure bay number occupied by the blade.
In case of a blade occupying multiple bays, this will be the lowest
enclosure bay number of all the bay numbers occupied by this balde |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
cpqSiServerBladeHeight |
1.3.6.1.4.1.232.2.2.14.2 |
Blade height is the Blade length.
unknown(1)
This indicates it could not be determined.
halfHeightBlade(2)
This indicates a half-height server Blade.
fullHeightBlade(3)
This indicates a full-height server Blade. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
unknown(1), halfHeightBlade(2), fullHeightBlade(3) |
|
cpqSiServerBladeWidth |
1.3.6.1.4.1.232.2.2.14.3 |
Width of the Blade in terms of Enclosure Bays. This pertain to the
Blade side that connects to the enclosure backplane. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
unknown(1), singleWide(2), doubleWide(3) |
|
cpqSiRackName |
1.3.6.1.4.1.232.2.2.15.1 |
The rack name. This name is used to logically group together
enclosures in a rack and it is shared with other enclosures
in the rack.
The string will be empty if it could not be determined. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
cpqSiRackUUID |
1.3.6.1.4.1.232.2.2.15.2 |
The rack unique identifier. The string will be empty
if it could be determined. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
cpqSiMPHostName |
1.3.6.1.4.1.232.2.2.16.1 |
The host name of the Management Processor.
The string will be empty if it could not be determined. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
cpqSiMPHealthStatus |
1.3.6.1.4.1.232.2.2.16.2 |
The health status of the Management Processor. |
Status: optional |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
unknown(1), ok(2), degraded(3), failed(4) |
|
cpqSiHoodRemoved |
2001 |
System hood is removed.
The hood status has been set to removed. The
system's hood is not in a properly installed state. This
situation may result in improper cooling of the system due
to air flow changes caused by the missing hood.
User Action: Replace the cover (hood), ensure the system's cover
is properly installed. Verify the system is in working order. |
TRAP-TYPE |
|
|
|
cpqSiMonitorConditionOK |
2002 |
Fault reporting features have returned to within their normal
operating range for the monitor indicated by cpqSiMonitorIndex.
The monitor's condition has been set to OK.
User Action: None. |
TRAP-TYPE |
|
|
|
cpqSiMonitorConditionDegraded |
2003 |
A fault reporting feature has exceeded normal limits for
the monitor indicated by the cpqSiMonitorIndex. The monitor's
condition is degraded due to the internal temperature exceeding
normal operating limits. The monitor is still useable, but
action should be taken to return the condition to OK.
User Action: Physically check for obstructions to air flow around
the monitor. Check the thermostat in the room that the system
occupies. Allow the monitor to cool by turning off the monitor
for 5 minutes then turn the monitor back on. After the monitor
cools, another alarm indicating an improving condition, such as
Monitor OK, will be issued. |
TRAP-TYPE |
|
|
|
cpqSiMonitorConditionFailed |
2004 |
A fault reporting feature has exceeded normal limits in the
monitor indicated by the cpqSiMonitorIndex. The monitor's
condition has been set to failed due to an operational feature
exceeding normal operating limits. The monitor will not be
useable and should be replaced.
User Action: Make a note of the monitor model number and serial
number. Replace the monitor.
Refer to the appropriate Maintenance and Service Guide for
detailed information on a component replacement. |
TRAP-TYPE |
|
|
|
cpqSiCorrMemErrStatusDegraded |
2005 |
Correctable memory error count has exceeded the threshold for the
memory module indicated by the 'cpqSiMemErrorIndex' variable.
The appropriate cpqSiMemModuleECCStatus has been set to degraded.
User Action: For Desktops, the System Administrator should run
the F10 Diagnostics on this system and select RAM LONG TEST. If
it is determined that a module needs replacing, schedule
maintenance for the system and replace the failed memory module.
Refer to the appropriate Maintenance and Service Guide for detailed
information on a component replacement. |
TRAP-TYPE |
|
|
|
cpqSiCorrMemErrStatusOk |
2006 |
Correctable memory error count is now below the threshold for the
memory module indicated by the 'cpqSiMemErrorIndex' variable. The
appropriate cpqSiMemModuleECCStatus has been set to ok.
User Action: None. |
TRAP-TYPE |
|
|
|
cpqSiMemConfigChange |
2007 |
A memory configuration change has occurred. CpqSiMemConfigChangeData
will indicate which memory modules slots have changed.
User Action: You may want to verify a valid reason for a memory
configuration to have occurred. If system issuing the alert is
a Desktop running NT, the memory configuration change information
is also logged in the NT System Log. |
TRAP-TYPE |
|
|
|
cpqSiHotPlugSlotBoardRemoved |
2008 |
Hot Plug Slot Board Removed.
A Hot Plug Slot Board has been removed from the specified
chassis and slot.
User Action: None. |
TRAP-TYPE |
|
|
|
cpqSiHotPlugSlotBoardInserted |
2009 |
Hot Plug Slot Board Inserted.
A Hot Plug Slot Board has been inserted into the specified
chassis and slot.
User Action: None. |
TRAP-TYPE |
|
|
|
cpqSiHotPlugSlotPowerUpFailed |
2010 |
Hot Plug Slot Board Failed Power-Up.
A Hot Plug Slot Board has failed to power-up in the specified
chassis and slot.
User Action: Insure the board and all cables are installed
correctly and the board type and revision are the same as
the replaced board. |
TRAP-TYPE |
|
|
|
cpqSiSysBatteryFailure |
2011 |
The battery indicated by cpqSiSysBatteryIndex has failed
and must be replaced.
User Action: Contact your System Administrator or
Authorized Reseller to order a replacement battery.
Recycle your old battery. For proper disposal information,
refer to the documentation that came with your computer. |
TRAP-TYPE |
|
|
|
cpqSiSysBatteryChargingDegraded |
2012 |
Significant battery degradation has occurred with battery
indicated by cpqSiSysBatteryIndex. The battery can
no longer be fully recharged.
User Action: If using multiple batteries, run
the Power Conservation Utility to identify the
battery location. Contact your System Administrator
or Authorized Reseller to order a replacement
battery. |
TRAP-TYPE |
|
|
|
cpqSiSysBatteryCalibrationError |
2013 |
Calibration is needed with battery
indicated by cpqSiSysBatteryIndex. The battery can
not correctly indicate capacity.
User Action: Run the Power Conservation Utility. Contact
your System Administrator or Authorized Reseller to
order a replacement battery. |
TRAP-TYPE |
|
|
|