CPQSINFO-MIB

File: CPQSINFO-MIB.mib (143122 bytes)

Imported modules

CPQHOST-MIB RFC1213-MIB RFC-1212
RFC-1215

Imported symbols

compaq DisplayString OBJECT-TYPE
sysName cpqHoTrapFlags TRAP-TYPE

Defined Types

CpqSiOsCommonModuleEntry  
SEQUENCE    
  cpqSiOsCommonModuleIndex INTEGER
  cpqSiOsCommonModuleName DisplayString
  cpqSiOsCommonModuleVersion DisplayString
  cpqSiOsCommonModuleDate OCTET STRING
  cpqSiOsCommonModulePurpose DisplayString

CpqSiVirtualSystemEntry  
SEQUENCE    
  cpqSiVirtualSystemIndex INTEGER
  cpqSiVirtualSystemSerialNumber DisplayString
  cpqSiVirtualSystemUUID DisplayString

CpqSiMemModuleEntry  
SEQUENCE    
  cpqSiMemBoardIndex INTEGER
  cpqSiMemModuleIndex INTEGER
  cpqSiMemModuleSize INTEGER
  cpqSiMemModuleType INTEGER
  cpqSiMemModuleSpeed INTEGER
  cpqSiMemModuleTechnology INTEGER
  cpqSiMemModuleManufacturer DisplayString
  cpqSiMemModulePartNo DisplayString
  cpqSiMemModuleDate OCTET STRING
  cpqSiMemModuleSerialNo DisplayString
  cpqSiMemModuleECCStatus INTEGER
  cpqSiMemModuleHwLocation DisplayString
  cpqSiMemModuleFrequency INTEGER
  cpqSiMemModuleCellTablePtr INTEGER
  cpqSiMemModuleCellStatus INTEGER
  cpqSiMemModulePartNoMfgr DisplayString
  cpqSiMemModuleSerialNoMfgr DisplayString

CpqSiProcMicroPatchEntry  
SEQUENCE    
  cpqSiProcMicroPatchIndex INTEGER
  cpqSiProcMicroPatchId INTEGER
  cpqSiProcMicroPatchDate OCTET STRING
  cpqSiProcMicroPatchFamily OCTET STRING

CpqSiPerfStateEntry  
SEQUENCE    
  cpqSiPerfStateIndex INTEGER
  cpqSiPerfState INTEGER
  cpqSiPerfStateCpuFrequency INTEGER
  cpqSiPerfStateCpuPower INTEGER

CpqSiBoardRevEntry  
SEQUENCE    
  cpqSiBoardRevSlotIndex INTEGER
  cpqSiBoardRevIndex INTEGER
  cpqSiBoardRevId DisplayString
  cpqSiBoardRevCur DisplayString
  cpqSiBoardRevPrev DisplayString
  cpqSiBoardRevHwLocation DisplayString

CpqSiFirmwareRevEntry  
SEQUENCE    
  cpqSiFirmwareRevIndex INTEGER
  cpqSiFirmwareRevDesc DisplayString
  cpqSiFirmwareRevString DisplayString
  cpqSiFirmwareRevCellTablePtr INTEGER
  cpqSiFirmwareLocation DisplayString
  cpqSiFirmwareStatus INTEGER

CpqSiFirmwareCfgEntry  
SEQUENCE    
  cpqSiFirmwareCfgName DisplayString
  cpqSiFirmwareCfgValue DisplayString

CpqSiMonitorEntry  
SEQUENCE    
  cpqSiMonitorIndex INTEGER
  cpqSiMonitorEdidRaw OCTET STRING
  cpqSiMonitorDesc DisplayString
  cpqSiMonitorSerialNumber DisplayString
  cpqSiMonitorManufactureDate OCTET STRING
  cpqSiMonitorHeight INTEGER
  cpqSiMonitorWidth INTEGER
  cpqSiMonitorMaxHorPixel INTEGER
  cpqSiMonitorMaxVertPixel INTEGER
  cpqSiMonitorMaxRefreshRate INTEGER
  cpqSiMonitorManufacturer DisplayString
  cpqSiMonitorThermalCondition INTEGER
  cpqSiMonitorOperationalCondition INTEGER
  cpqSiMonitorStatus INTEGER

CpqSiHotPlugSlotEntry  
SEQUENCE    
  cpqSiHotPlugSlotChassis INTEGER
  cpqSiHotPlugSlotIndex INTEGER
  cpqSiHotPlugSlotBoardPresent INTEGER
  cpqSiHotPlugSlotPowerState INTEGER
  cpqSiHotPlugSlotBoardCondition INTEGER
  cpqSiHotPlugSlotErrorStatus INTEGER
  cpqSiHotPlugSlotHwLocation DisplayString

CpqSiSysBatteryEntry  
SEQUENCE    
  cpqSiSysBatteryIndex INTEGER
  cpqSiSysBatteryModel DisplayString
  cpqSiSysBatterySerialNum DisplayString
  cpqSiSysBatteryAssetTag DisplayString
  cpqSiSysBatteryManufacturer DisplayString
  cpqSiSysBatteryDate OCTET STRING
  cpqSiSysBatterySmartVersion DisplayString
  cpqSiSysBatteryCondition INTEGER
  cpqSiSysBatteryStatus INTEGER
  cpqSiSysBatteryChemistry INTEGER
  cpqSiSysBatteryRemainingCap INTEGER
  cpqSiSysBatteryFirmwareRevision INTEGER
  cpqSiSysBatteryHardwareRevision INTEGER
  cpqSiSysBatteryFullCap INTEGER
  cpqSiSysBatteryDesignCap INTEGER
  cpqSiSysBatteryHwLocation DisplayString

CpqSiFruEntry  
SEQUENCE    
  cpqSiFruIndex INTEGER
  cpqSiFruType INTEGER
  cpqSiFruDescr DisplayString
  cpqSiFruVendor DisplayString
  cpqSiFruPartNumber DisplayString
  cpqSiFruRevision DisplayString
  cpqSiFruFirmwareRevision DisplayString
  cpqSiFruSerialNumber DisplayString
  cpqSiFruAssetNo DisplayString
  cpqSiFruClass INTEGER
  cpqSiFruSlotNumber DisplayString
  cpqSiFruSubAssemblyNumber INTEGER
  cpqSiFruAssemblyNumber INTEGER
  cpqSiFruChassisNumber INTEGER
  cpqSiFruPositionNumber INTEGER
  cpqSiFruCabinetIDNumber INTEGER
  cpqSiFruSiteLocation INTEGER
  cpqSiFruDiagStatus INTEGER
  cpqSiFruExtendedDiagStatus INTEGER
  cpqSiFruCellTablePtr INTEGER
  cpqSiFruIOCTablePtr INTEGER
  cpqSiFruFileId DisplayString
  cpqSiFruScanRev DisplayString

CpqSiRackEnclosureMgrEntry  
SEQUENCE    
  cpqSiRackEnclosureMgrIndex INTEGER
  cpqSiRackEnclosureMgrType INTEGER
  cpqSiRackEnclosureMgrIpAddr DisplayString
  cpqSiRackEnclosureMgrWebLink DisplayString
  cpqSiRackEnclosureMgrCondition INTEGER
  cpqSiRackEnclosureMgrSerialNumber DisplayString
  cpqSiRackEnclosureMgrModel DisplayString
  cpqSiRackEnclosureMgrName DisplayString
  cpqSiRackEnclosureMgrFwRev DisplayString
  cpqSiRackEnclosureMgrProductID DisplayString
  cpqSiRackEnclosureMgrUUID DisplayString

Defined Values

cpqSystemInfo 1.3.6.1.4.1.232.2
OBJECT IDENTIFIER    

cpqSiMibRev 1.3.6.1.4.1.232.2.1
OBJECT IDENTIFIER    

cpqSiComponent 1.3.6.1.4.1.232.2.2
OBJECT IDENTIFIER    

cpqSiInterface 1.3.6.1.4.1.232.2.2.1
OBJECT IDENTIFIER    

cpqSiAsset 1.3.6.1.4.1.232.2.2.2
OBJECT IDENTIFIER    

cpqSiSecurity 1.3.6.1.4.1.232.2.2.3
OBJECT IDENTIFIER    

cpqSiSystemBoard 1.3.6.1.4.1.232.2.2.4
OBJECT IDENTIFIER    

cpqSiBoardRev 1.3.6.1.4.1.232.2.2.5
OBJECT IDENTIFIER    

cpqSiRackServer 1.3.6.1.4.1.232.2.2.6
OBJECT IDENTIFIER    

cpqSiVideo 1.3.6.1.4.1.232.2.2.7
OBJECT IDENTIFIER    

cpqSiMonitor 1.3.6.1.4.1.232.2.2.8
OBJECT IDENTIFIER    

cpqSiHotPlugSlot 1.3.6.1.4.1.232.2.2.9
OBJECT IDENTIFIER    

cpqSiSystemBattery 1.3.6.1.4.1.232.2.2.10
OBJECT IDENTIFIER    

cpqSiDockingStation 1.3.6.1.4.1.232.2.2.11
OBJECT IDENTIFIER    

cpqSiFru 1.3.6.1.4.1.232.2.2.12
OBJECT IDENTIFIER    

cpqSiRackEnclosure 1.3.6.1.4.1.232.2.2.13
OBJECT IDENTIFIER    

cpqSiServerBlade 1.3.6.1.4.1.232.2.2.14
OBJECT IDENTIFIER    

cpqSiRack 1.3.6.1.4.1.232.2.2.15
OBJECT IDENTIFIER    

cpqSiMP 1.3.6.1.4.1.232.2.2.16
OBJECT IDENTIFIER    

cpqSiOsCommon 1.3.6.1.4.1.232.2.2.1.4
OBJECT IDENTIFIER    

cpqSiMibRevMajor 1.3.6.1.4.1.232.2.1.1
The major revision level of the MIB. A change in the major revision level represents a major change in the architecture of the MIB. A change in the major revision level may indicate a significant change in the information supported and/or the meaning of the supported information, correct interpretation of data may require a MIB document with the same major revision level.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

cpqSiMibRevMinor 1.3.6.1.4.1.232.2.1.2
The minor revision level of the MIB. A change in the minor revision level may represent some minor additional support, no changes to any pre-existing information has occurred.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

cpqSiMibCondition 1.3.6.1.4.1.232.2.1.3
The overall condition. This object represents the overall status of the server information represented by this MIB.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), ok(2), degraded(3), failed(4)  

cpqSiOsCommonPollFreq 1.3.6.1.4.1.232.2.2.1.4.1
The Insight Agent's polling frequency. The frequency, in seconds, at which the Insight Agent requests information from the device driver. A frequency of zero (0) indicates that the Insight Agent retrieves the information upon request of a management station, it does not poll the device driver at a specific interval. If the poll frequency is zero (0) all attempts to write to this object will fail. If the poll frequency is non-zero, setting this value will change the polling frequency of the Insight Agent. Setting the poll frequency to zero (0) will always fail, an agent may also choose to fail any request to change the poll frequency to a value that would severely impact system performance.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER 0..65535  

cpqSiOsCommonModuleTable 1.3.6.1.4.1.232.2.2.1.4.2
A table of software modules that provide an interface to the device this MIB describes.
Status: deprecated Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CpqSiOsCommonModuleEntry

cpqSiOsCommonModuleEntry 1.3.6.1.4.1.232.2.2.1.4.2.1
A description of a software module that provides an interface to the device this MIB describes.
Status: deprecated Access: not-accessible
OBJECT-TYPE    
  CpqSiOsCommonModuleEntry  

cpqSiOsCommonModuleIndex 1.3.6.1.4.1.232.2.2.1.4.2.1.1
A unique index for this module description.
Status: deprecated Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

cpqSiOsCommonModuleName 1.3.6.1.4.1.232.2.2.1.4.2.1.2
The module name.
Status: deprecated Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

cpqSiOsCommonModuleVersion 1.3.6.1.4.1.232.2.2.1.4.2.1.3
The module version in XX.YY format. Where XX is the major version number and YY is the minor version number. This field will be a null (size 0) string if the agent cannot provide the module version.
Status: deprecated Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..5)  

cpqSiOsCommonModuleDate 1.3.6.1.4.1.232.2.2.1.4.2.1.4
The module date. field octets contents range ===== ====== ======= ===== 1 1-2 year 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minute 0..59 6 7 second 0..60 (use 60 for leap-second) This field will be set to year = 0 if the agent cannot provide the module date. The hour, minute, and second field will be set to zero (0) if they are not relevant. The year field is set with the most significant octet first.
Status: deprecated Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(7)  

cpqSiOsCommonModulePurpose 1.3.6.1.4.1.232.2.2.1.4.2.1.5
The purpose of the module described in this entry.
Status: deprecated Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

cpqSiSysSerialNum 1.3.6.1.4.1.232.2.2.2.1
The serial number of the physical system unit. The string will be empty if the system does not report the serial number function.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

cpqSiFormFactor 1.3.6.1.4.1.232.2.2.2.2
The form factor of the system. Setting this variable to unknown will fail.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER unknown(1), portable(2), laptop(3), desktop(4), tower(5), mini-tower(6), rack-mount(7)  

cpqSiAssetTag 1.3.6.1.4.1.232.2.2.2.3
The customer changeable identifier that is set to the system serial number at the time of manufacture. The string will be empty if the system does not report this function.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..255)  

cpqSiOwnershipTag 1.3.6.1.4.1.232.2.2.2.4
This is a customer changeable identifier that will be displayed by ROM at POST. This is an 80 byte standard ASCII character string and is Administrator Password protected. An example could be: Property of Hewlett-Packard Company The string should be NULL terminated. This item will be empty if the system does not report this function.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..79)  

cpqSiSysServiceNum 1.3.6.1.4.1.232.2.2.2.5
The service number of the system unit. The string will be empty if the system does not report the system service number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

cpqSiSysProductId 1.3.6.1.4.1.232.2.2.2.6
The product id string of the system unit. The string will be empty if the system does not report the product id.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

cpqSiAssetTagMaxLength 1.3.6.1.4.1.232.2.2.2.7
Maximum allowed size in bytes of the asset tag.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqSiVirtualSystemTable 1.3.6.1.4.1.232.2.2.2.8
A table of virtual system information entries.
Status: optional Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CpqSiVirtualSystemEntry

cpqSiVirtualSystemEntry 1.3.6.1.4.1.232.2.2.2.8.1
A virtual system information table entry.
Status: optional Access: not-accessible
OBJECT-TYPE    
  CpqSiVirtualSystemEntry  

cpqSiVirtualSystemIndex 1.3.6.1.4.1.232.2.2.2.8.1.1
The unique index of the virtual system information entry.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

cpqSiVirtualSystemSerialNumber 1.3.6.1.4.1.232.2.2.2.8.1.2
The HP Virtual Serial Number for the computer system package. The Virtual Serial Number is the system serial number exposed to the operating system when running in an HP Virtual Connect environment. The Virtual Serial Number presented here will correspond to the Virtual UUID at the same index location.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString  

cpqSiVirtualSystemUUID 1.3.6.1.4.1.232.2.2.2.8.1.3
The HP Virtual UUID for the computer system package. The Virtual UUID is the UUID number exposed to the operating system when running in an HP Virtual Connect environment. The Virtual UUID presented here will correspond to the Virtual serial number at the same index location.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString  

cpqSiPowerOnPassword 1.3.6.1.4.1.232.2.2.3.1
The state of the power on password feature.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), disabled(2), enabled(3)  

cpqSiNetServerMode 1.3.6.1.4.1.232.2.2.3.2
The state of the network server mode feature.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), disabled(2), enabled(3)  

cpqSiQuickLockPassword 1.3.6.1.4.1.232.2.2.3.3
The state of the quicklock password feature.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), disabled(2), enabled(3)  

cpqSiQuickBlank 1.3.6.1.4.1.232.2.2.3.4
The state of the quick blank screen feature.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), disabled(2), enabled(3)  

cpqSiDisketteBootControl 1.3.6.1.4.1.232.2.2.3.5
The state of the diskette boot control feature.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), disabled(2), enabled(3)  

cpqSiSerialPortAControl 1.3.6.1.4.1.232.2.2.3.6
The state of the access control for the primary serial port interface embedded in the system board.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), disabled(2), enabled(3)  

cpqSiSerialPortBControl 1.3.6.1.4.1.232.2.2.3.7
The state of the access control for the secondary serial port interface embedded in the system board.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), disabled(2), enabled(3)  

cpqSiParallelPortControl 1.3.6.1.4.1.232.2.2.3.8
The state of the access control for the parallel port interface embedded in the system board.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), disabled(2), enabled(3)  

cpqSiFloppyDiskControl 1.3.6.1.4.1.232.2.2.3.9
The state of the access control for the floppy diskette interface embedded in the system board.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), disabled(2), enabled(3)  

cpqSiFixedDiskControl 1.3.6.1.4.1.232.2.2.3.10
The state of the access control for the fixed disk interface embedded in the system board.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), disabled(2), enabled(3)  

cpqSiHoodRemovedTime 1.3.6.1.4.1.232.2.2.3.11
Last detection of hood removed by Smart Hood Sensor.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

cpqSiHoodSensorConfiguration 1.3.6.1.4.1.232.2.2.3.12
This is the current configuration of the Smart Cover sensor. The following values are currently defined: other(1) Smart Cover sensor is not supported on this system or cannot be determined by the Insight Agent. You may need to upgrade your software. disabled(2) Smart Cover sensor will not detect a hood removal and cpqSiHoodRemovedTime will not be updated. notifyUser(3) Smart Cover sensor will detect a hood removal and will display a message at POST for the user. adminPasswordProtected(4) Smart Cover sensor will detect a hood removal and will display a message at POST for the user to enter the Admin Password. The system will not boot until proper password is entered.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), disabled(2), notifyUser(3), adminPasswordProtected(4)  

cpqSiSmartCoverLockStatus 1.3.6.1.4.1.232.2.2.3.13
This is the current status of the Smart Cover Lock. The following values are currently defined: other(1) Smart Cover Lock is not supported on this system or cannot be determined by the Insight Agent. You may need to upgrade your software. unlocked(2) Smart Cover Lock is not locked. The status will be set to unlocked due to one of the following: 1. The system hood is removed, or 2. There is no administrator password set, or 3. The administrator manually sets status to unlock. locked(3) Smart Cover Lock is locked. The administrator password is required to unlock the hood.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), unlocked(2), locked(3)  

cpqSiUSBPortControl 1.3.6.1.4.1.232.2.2.3.14
The state of the access control for the Universal Serial Bus interface(s) embedded in the system board. other(1) If Status could not be determined. disabled(2) USB interface is disable. enabled(3) USB interface is enable. legacydisabled(4) Legacy USB interface is disabled. externalportdisabled(5) External USB Ports are disabled.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), disabled(2), enabled(3), legacydisabled(4), externalportdisabled(5)  

cpqSiProductId 1.3.6.1.4.1.232.2.2.4.1
The machine product ID. This value indicates the product type of the system board in this system. The value 127 will be given if the machine ID cannot be determined. A value of 127 will also be used for the special case of a machine containing neither EISA nor ISA slots.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

cpqSiProductName 1.3.6.1.4.1.232.2.2.4.2
The machine product name. The name of the machine used in this system.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

cpqSiAuxiliaryInput 1.3.6.1.4.1.232.2.2.4.4
The state of the auxiliary input (pointing) device.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), disabled(2), enabled(3)  

cpqSiMemModuleTable 1.3.6.1.4.1.232.2.2.4.5
A table of memory module descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CpqSiMemModuleEntry

cpqSiMemModuleEntry 1.3.6.1.4.1.232.2.2.4.5.1
A memory module description.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  CpqSiMemModuleEntry  

cpqSiMemBoardIndex 1.3.6.1.4.1.232.2.2.4.5.1.1
The slot in which the memory board or cartridge is installed. A value of 0 indicates memory installed directly on the system board.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

cpqSiMemModuleIndex 1.3.6.1.4.1.232.2.2.4.5.1.2
The memory module number.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

cpqSiMemModuleSize 1.3.6.1.4.1.232.2.2.4.5.1.3
Module memory size in kilobytes. A kilobyte of memory is defined as 1024 bytes. A size of 0 indicates the module is not present.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..2147483647  

cpqSiMemModuleType 1.3.6.1.4.1.232.2.2.4.5.1.4
Type of memory module installed. The value other(1) will be given if the type is not known. The value board(2) will be given if the memory module is permanently mounted (not modular) on a system board or memory expansion board.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), board(2), cpqSingleWidthModule(3), cpqDoubleWidthModule(4), simm(5), pcmcia(6), compaq-specific(7), dimm(8), smallOutlineDimm(9), rimm(10), srimm(11), fb-dimm(12)  

cpqSiMemModuleSpeed 1.3.6.1.4.1.232.2.2.4.5.1.5
Module memory speed in nanoseconds. The value zero (0) will be given if the module speed cannot be determined.
Status: deprecated Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

cpqSiMemModuleTechnology 1.3.6.1.4.1.232.2.2.4.5.1.6
Technology type of memory module installed. The value other(1) will be given if the technology is not known.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), fastPageMode(2), edoPageMode(3), burstEdoPageMode(4), synchronous(5), rdram(6)  

cpqSiMemModuleManufacturer 1.3.6.1.4.1.232.2.2.4.5.1.7
The memory module's manufacturer name. This field will be a null (size 0) string if the manufacturer name is not available.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

cpqSiMemModulePartNo 1.3.6.1.4.1.232.2.2.4.5.1.8
The memory module's manufacturer part number. This field will be a null (size 0) string if the manufacturer part number is not available.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

cpqSiMemModuleDate 1.3.6.1.4.1.232.2.2.4.5.1.9
The memory module date of manufacture. field octets contents range ===== ====== ====================== ======== 1 1-2 year 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minute 0..59 6 7 second 0..60 (use 60 for leap-second) This field will be set to year = 0 if the date of manufacture is not available. The hour, minute, and second fields will always be set to 0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(7)  

cpqSiMemModuleSerialNo 1.3.6.1.4.1.232.2.2.4.5.1.10
The memory module's serial number. This field will be a null (size 0) string if the serial number is not available.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..255)  

cpqSiMemModuleECCStatus 1.3.6.1.4.1.232.2.2.4.5.1.11
This provides the current status of the correctable memory errors for this memory module. The following status values are supported: other(1): ECC is not supported on this memory module. ok(2): The correctable error count is below threshold. degraded(3): The correctable error count has exceeded threshold. degradedModuleIndexUnknown(4): The correctable error count has exceeded threshold. The module index not available.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), ok(2), degraded(3), degradedModuleIndexUnknown(4)  

cpqSiMemModuleHwLocation 1.3.6.1.4.1.232.2.2.4.5.1.12
A text description of the hardware location, on complex multi SBB hardware only, for the memory module. A NULL string indicates that the hardware location could not be determined or is irrelevant.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

cpqSiMemModuleFrequency 1.3.6.1.4.1.232.2.2.4.5.1.13
The memory module frequency in MHz. The value zero (0) will be given if the module frequency cannot be determined.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

cpqSiMemModuleCellTablePtr 1.3.6.1.4.1.232.2.2.4.5.1.14
Index for the cell in cpqSeCellTable where the memory board is installed.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 0..15  

cpqSiMemModuleCellStatus 1.3.6.1.4.1.232.2.2.4.5.1.15
This provides the current status for this memory module. The following status values are supported: other(1): The memory module status is not available ok(2): The memory module is active deconfigured(3): The memory module is not ready
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER other(1), ok(2), deconfigured(3)  

cpqSiMemModulePartNoMfgr 1.3.6.1.4.1.232.2.2.4.5.1.16
The memory module's manufacturer's part number. This field will be a null (size 0) string if the manufacturer part number is not available.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

cpqSiMemModuleSerialNoMfgr 1.3.6.1.4.1.232.2.2.4.5.1.17
The memory module's manufacturer's serial number. This field will be a null (size 0) string if the manufacturer serial number is not available.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

cpqSiSystemId 1.3.6.1.4.1.232.2.2.4.6
The System ID. This value indicates the system ID of the system board in this system. This ID replaces the product ID used in older machines (cpqSiProductId). A value of 7Eh for the cpqSiProductId indicates that the cpqSiSystemId should be used to identify the system. A value of zero (0) indicates that the system ID function is not supported on this machine. In this case, the cpqSiProductId should be used to identify the system.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

cpqSiSystemCpuId 1.3.6.1.4.1.232.2.2.4.7
The System ID : CPU Component. This value indicates the CPU type of the system board in this system. A value of zero (0) indicates that the CPU type cannot be determined.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

cpqSiFlashRomSupport 1.3.6.1.4.1.232.2.2.4.8
This value indicates if this system supports flash upgradable system ROM.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), notSupported(2), supported(3)  

cpqSiQuickTestRomDate 1.3.6.1.4.1.232.2.2.4.9
This value indicates the date of the current quick test ROM image. field octets contents range ===== ====== ======= ===== 1 1-2 year 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minute 0..59 6 7 second 0..60 (use 60 for leap-second) This field will be set to year = 0 if quick test ROM is not present. The hour, minute, and second field will be set to zero (0) if they are not relevant. The year field is set with the most significant octet first.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(7)  

cpqSiReboot 1.3.6.1.4.1.232.2.2.4.10
This object may contain the following values: notAvailable(1) the system does not support the reboot functionality. Setting this object to notAvailable(1) has no effect. available(2) the system supports the both reboot to functionalities. Setting this object to available(2) has no effect. defaultOnlyAvailable(3) the system supports the only the default reboot functionality. Setting this object to available(3) has no effect. rebootToCpqUtils(2693) the system will reboot to the System Utilities if the reboot functionality is available. If possible, the agent will attempt to gracefully shutdown the operating system before performing the reboot. If this functionality is unavailable on this system then all sets will have no effect. rebootToDefault(8115) the system will reboot and allow the default boot process to occur if the reboot functionality is available. If possible, the agent will attempt to gracefully shutdown the operating system before performing the reboot. If this functionality is unavailable on this system then all sets will have no effect. autoShutdown(9037) If possible, the agent will attempt to gracefully shutdown the operating system. The agent will not preform a reboot.
Status: deprecated Access: read-write
OBJECT-TYPE    
  INTEGER notAvailable(1), available(2), defaultOnlyAvailable(3), rebootToCpqUtils(2693), rebootToDefault(8115), autoShutdown(9037)  

cpqSiProcMicroPatchTable 1.3.6.1.4.1.232.2.2.4.11
This table lists the set of processor microcode patches that the system ROM contains. During post, the ROM will apply the appropriate patches to the CPU microcode. Scan this table to ensure that a patch is being applied to a processor.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CpqSiProcMicroPatchEntry

cpqSiProcMicroPatchEntry 1.3.6.1.4.1.232.2.2.4.11.1
An entry describing one microcode patch contained in the system ROM.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  CpqSiProcMicroPatchEntry  

cpqSiProcMicroPatchIndex 1.3.6.1.4.1.232.2.2.4.11.1.1
Index into the microcode patch table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..255  

cpqSiProcMicroPatchId 1.3.6.1.4.1.232.2.2.4.11.1.2
The ID of this particular CPU microcode patch.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqSiProcMicroPatchDate 1.3.6.1.4.1.232.2.2.4.11.1.3
This value indicates the date of this CPU microcode patch. field octets contents range ===== ====== ======= ===== 1 1-2 year 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minute 0..59 6 7 second 0..60 (use 60 for leap-second) NOTE: Year is stored in packed BCD. The most significant part is in the second octet. For example: 1995 would be stored as 0x95 0x19. The hour, minute, and second field will be set to zero (0) if they are not relevant. The year field is set with the most significant octet first.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(7)  

cpqSiProcMicroPatchFamily 1.3.6.1.4.1.232.2.2.4.11.1.4
The valid family/model/step of the processor that this CPU microcode patch applies to. field octets contents range ===== ====== ======= ===== 1 1 CPU Step 0..255 2 2 CPU Model 0..255 3 3 CPU Family 0..255
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(3)  

cpqSiPowerMgmtStatus 1.3.6.1.4.1.232.2.2.4.12
The state of power management.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), disabled(2), enabled(3)  

cpqSiRebootFlags 1.3.6.1.4.1.232.2.2.4.13
The Reboot Flags. This is a collection of flags used to indicate the re-boot options available. This integer is a bitmap, with each bit indicating the availability of an option. If the bit is set to 1, the option is available; otherwise it is not. Multiple options are allowed. NOTE: bit 31 is the most significant bit, bit 0 is the least significant. Status This is a collection of flags. Each bit has the following meaning when it is on (1): Bit 31: Execute Set Bit 30-6: RESERVED Bit 5: Boot to ROM Based Setup Bit 4: RESERVED Bit 3: Boot to OS Bit 2: Boot to Utils Bit 1: Warm Boot Bit 0: Cold Boot
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

cpqSiMemErrorIndex 1.3.6.1.4.1.232.2.2.4.14
Placeholder for memory module number for ECC traps. Represents the number of the memory module for which an ECC status change has occurred. Set to 65535 if module number not available.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

cpqSiMemECCCondition 1.3.6.1.4.1.232.2.2.4.15
This provides the current condition of the correctable memory errors for the entire memory. The following status values are supported: other(1) : ECC is not supported. ok(2) : The correctable error count is below threshold. degraded(3) : The correctable error count has exceeded threshold.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), ok(2), degraded(3)  

cpqSiMemConfigChangeData 1.3.6.1.4.1.232.2.2.4.16
Text string for the memory configuration change trap.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..383)  

cpqSiServerSystemId 1.3.6.1.4.1.232.2.2.4.17
A Server System ID. This value is used to uniquely identify systems via a unique ID on systems that do not support the EISA bus.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..8)  

cpqSiPowerScheme 1.3.6.1.4.1.232.2.2.4.18
The current active power plan or power scheme of the system.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER unsupported(1), other(2), power-saver(3), balanced(4), high-performance(5), user-defined(6)  

cpqSiPowerSchemeName 1.3.6.1.4.1.232.2.2.4.19
The name of current active power plan or power scheme of the system. When cpqSiPowerScheme has a value of user-defined(6), the user defined name can be populated here.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

cpqSiCurrentPerformanceStatePointer 1.3.6.1.4.1.232.2.2.4.20
Pointer to cpqSiPerfStateIndex in cpqSiPerfStateTable to indicate the current performance state of the system.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

cpqSiMinPerformanceState 1.3.6.1.4.1.232.2.2.4.21
The slowest performance state by the selected power state policy.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

cpqSiMaxPerformanceState 1.3.6.1.4.1.232.2.2.4.22
The fastest performance state supported by the selected power state policy.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

cpqSiPerfStateTable 1.3.6.1.4.1.232.2.2.4.23
A table of supported performance states of the system.
Status: optional Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CpqSiPerfStateEntry

cpqSiPerfStateEntry 1.3.6.1.4.1.232.2.2.4.23.1
An entry describing a supported performance state of the system.
Status: optional Access: not-accessible
OBJECT-TYPE    
  CpqSiPerfStateEntry  

cpqSiPerfStateIndex 1.3.6.1.4.1.232.2.2.4.23.1.1
Index into the performance state table. cpqSiCurrentPerformanceStatePointer should point to one of these values.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

cpqSiPerfState 1.3.6.1.4.1.232.2.2.4.23.1.2
Performance state number. A unique number assigned to a performance state instance.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

cpqSiPerfStateCpuFrequency 1.3.6.1.4.1.232.2.2.4.23.1.3
The processor frequency in megahertz for this performance state instance.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 0..2147483647  

cpqSiPerfStateCpuPower 1.3.6.1.4.1.232.2.2.4.23.1.4
The processor power setting in milliwatts for this performance state instance.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER 0..2147483647  

cpqSiTPMmodule 1.3.6.1.4.1.232.2.2.4.24
This field will be populated if TPM module is present in the system board. other(1) No record of TPM exist. absent(2) TPM module is not present in the system. presentEnabled(3) TPM module is present in the system and currently enabled. presentDisabled(4) TPM module is present in the system and currently not enabled.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER other(1), absent(2), presentEnabled(3), presentDisabled(4)  

cpqSiCurRevDate 1.3.6.1.4.1.232.2.2.5.1
The current board revision configuration date in MM/DD/YY format. This is the date that the EISA Configuration Utility was used to define the current configuration. This value will contain 'N/A' if this system does not support this feature.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(8)  

cpqSiPrevRevDate 1.3.6.1.4.1.232.2.2.5.2
The previous board revision configuration date in MM/DD/YY format. This is the date that the EISA Configuration Utility was used to define the previous configuration. This value will contain 'N/A' if this system does not support this feature.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(8)  

cpqSiBoardRevTable 1.3.6.1.4.1.232.2.2.5.3
A table of board revision descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CpqSiBoardRevEntry

cpqSiBoardRevEntry 1.3.6.1.4.1.232.2.2.5.3.1
A board revision description.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  CpqSiBoardRevEntry  

cpqSiBoardRevSlotIndex 1.3.6.1.4.1.232.2.2.5.3.1.1
The slot in which the board described in this entry resides. Zero (0) indicates the system board.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

cpqSiBoardRevIndex 1.3.6.1.4.1.232.2.2.5.3.1.2
A number that uniquely specifies which board in a specific slot is described in this entry. Zero (0) indicates the main board in this slot. Any other number indicates a daughter board or a component of the main board.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

cpqSiBoardRevId 1.3.6.1.4.1.232.2.2.5.3.1.3
A description of the board type. The defined types are: Type ============== System Board Processor n (n = the processor number) Memory n (n = the memory board number) Slot n (n = the slot the board occupies) Other types may be defined at a later date.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..16)  

cpqSiBoardRevCur 1.3.6.1.4.1.232.2.2.5.3.1.4
The current revision for the board described in this entry. This value will be N/A if there is no current revision information.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..8)  

cpqSiBoardRevPrev 1.3.6.1.4.1.232.2.2.5.3.1.5
The revision for the board described in this entry prior to the current configuration. This value will be N/A if there is no previous revision information.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..8)  

cpqSiBoardRevHwLocation 1.3.6.1.4.1.232.2.2.5.3.1.6
A text description of the hardware location, on complex multi SBB hardware only, for the board. A NULL string indicates that the hardware location could not be determined or is irrelevant.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

cpqSiFirmwareRevTable 1.3.6.1.4.1.232.2.2.5.4
A table of firmware revision descriptions.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CpqSiFirmwareRevEntry

cpqSiFirmwareRevEntry 1.3.6.1.4.1.232.2.2.5.4.1
A firmware revision description.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  CpqSiFirmwareRevEntry  

cpqSiFirmwareRevIndex 1.3.6.1.4.1.232.2.2.5.4.1.1
Locally-unique index for this entry.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqSiFirmwareRevDesc 1.3.6.1.4.1.232.2.2.5.4.1.2
Description, e.g. SRM console, ARC console, System BIOS, etc.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cpqSiFirmwareRevString 1.3.6.1.4.1.232.2.2.5.4.1.3
Version number, possibly of the form Vx.y or Vx.y-z.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cpqSiFirmwareRevCellTablePtr 1.3.6.1.4.1.232.2.2.5.4.1.4
Index for the cell in cpqSeCellTable where this firmware is located
Status: deprecated Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqSiFirmwareLocation 1.3.6.1.4.1.232.2.2.5.4.1.5
Description of which board the firmware is located in.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

cpqSiFirmwareStatus 1.3.6.1.4.1.232.2.2.5.4.1.6
The current status for this firmware.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), active(2), inactive(3)  

cpqSiFirmwareCfgTable 1.3.6.1.4.1.232.2.2.5.5
Table of soft switches and symbols maintained by the firmware. May be operating system and/or option-specific and will certainly be system-specific. This list is intended to be easily extensible and support arbitrary datatypes. It includes such switches as powerup options, default dump device, etc. Note - the string comparison for svrFwSymbolName is case insensitive.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CpqSiFirmwareCfgEntry

cpqSiFirmwareCfgEntry 1.3.6.1.4.1.232.2.2.5.5.1
Each entry represents one variable or symbol maintained by or stored by some instance of firmware in the system.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  CpqSiFirmwareCfgEntry  

cpqSiFirmwareCfgName 1.3.6.1.4.1.232.2.2.5.5.1.1
The firmware configuration symbol name as visible from the console.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cpqSiFirmwareCfgValue 1.3.6.1.4.1.232.2.2.5.5.1.2
The firmware configuration symbol value. Null if none or unknown.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cpqSiRackServerShutdownRole 1.3.6.1.4.1.232.2.2.6.1
This entry describes this system's role in a rack-mounted uninterruptible power supply family. The master both communicates with the UPS and derives its power from the UPS. The slave derives its power from the UPS, but does not communicate with it.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER other(1), master(2), slave(3)  

cpqSiRackServerMasterName 1.3.6.1.4.1.232.2.2.6.2
This entry describes the name of the master server in a rack-mounted uninterruptible power supply family. A slave system would communicate with this server to derive UPS status.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..48)  

cpqSiVideoEdidRaw 1.3.6.1.4.1.232.2.2.7.1
The raw value returned from the video EDID function.
Status: deprecated Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(128)  

cpqSiVideoDesc 1.3.6.1.4.1.232.2.2.7.2
The manufacturer and model description of the video display.
Status: deprecated Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

cpqSiVideoSerialNumber 1.3.6.1.4.1.232.2.2.7.3
The serial number of the video display.
Status: deprecated Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..32)  

cpqSiVideoManufactureDate 1.3.6.1.4.1.232.2.2.7.4
The date of manufacture of the video display in the following format: field octets contents range ===== ====== ======= ===== 1 1-2 year 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minute 0..59 6 7 second 0..60 (use 60 for leap-second) This field will be set to year = 0 if the agent cannot provide the date. The date information that is given resolves to a year and week, so the hour, minute, and second field will be set to 0, the month and day fields will give the monday of the week of manufacture.
Status: deprecated Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(7)  

cpqSiVideoHeight 1.3.6.1.4.1.232.2.2.7.5
The maximum image height of the video display in centimeters
Status: deprecated Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

cpqSiVideoWidth 1.3.6.1.4.1.232.2.2.7.6
The maximum image width of the video display in centimeters
Status: deprecated Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

cpqSiVideoMaxHorPixel 1.3.6.1.4.1.232.2.2.7.7
The number of horizontal pixels in the highest resolution video mode supported.
Status: deprecated Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

cpqSiVideoMaxVertPixel 1.3.6.1.4.1.232.2.2.7.8
The number of vertical pixels in the highest resolution video mode supported.
Status: deprecated Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

cpqSiVideoMaxRefreshRate 1.3.6.1.4.1.232.2.2.7.9
The video refresh rate in Hz of the highest resolution video mode supported.
Status: deprecated Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

cpqSiMonitorOverallCondition 1.3.6.1.4.1.232.2.2.8.1
This value specifies the overall condition of the system's monitor(s). The following conditions are supported: other(1) The monitor does not support fault reporting or condition is unknown. ok(2) The monitor is operating OK. degraded(3) The monitor has detected a fault. The monitor is still useable but action should be taken to return the monitor to ok. failed(4) The monitor has detected a fault. The monitor will not be useable. Action should be taken to replace the monitor.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), ok(2), degraded(3), failed(4)  

cpqSiMonitorTable 1.3.6.1.4.1.232.2.2.8.2
A table of all video monitor descriptions connected to this system.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CpqSiMonitorEntry

cpqSiMonitorEntry 1.3.6.1.4.1.232.2.2.8.2.1
A video monitor description.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  CpqSiMonitorEntry  

cpqSiMonitorIndex 1.3.6.1.4.1.232.2.2.8.2.1.1
A unique index for each video display connected to the system.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..15  

cpqSiMonitorEdidRaw 1.3.6.1.4.1.232.2.2.8.2.1.2
The raw value returned from the video EDID function.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(128)  

cpqSiMonitorDesc 1.3.6.1.4.1.232.2.2.8.2.1.3
The manufacturer and model description of the video display.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

cpqSiMonitorSerialNumber 1.3.6.1.4.1.232.2.2.8.2.1.4
The serial number of the video display.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..32)  

cpqSiMonitorManufactureDate 1.3.6.1.4.1.232.2.2.8.2.1.5
The date of manufacture of the video display in the following format: field octets contents range ===== ====== ======= ===== 1 1-2 year 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minute 0..59 6 7 second 0..60 (use 60 for leap-second) This field will be set to year = 0 if the agent cannot provide the date. The date information that is given resolves to a year and week, so the hour, minute, and second field will be set to 0, the month and day fields will give the monday of the week of manufacture.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(7)  

cpqSiMonitorHeight 1.3.6.1.4.1.232.2.2.8.2.1.6
The maximum image height of the video display in centimeters
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

cpqSiMonitorWidth 1.3.6.1.4.1.232.2.2.8.2.1.7
The maximum image width of the video display in centimeters
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

cpqSiMonitorMaxHorPixel 1.3.6.1.4.1.232.2.2.8.2.1.8
The number of horizontal pixels in the highest resolution video mode supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

cpqSiMonitorMaxVertPixel 1.3.6.1.4.1.232.2.2.8.2.1.9
The number of vertical pixels in the highest resolution video mode supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

cpqSiMonitorMaxRefreshRate 1.3.6.1.4.1.232.2.2.8.2.1.10
The video refresh rate in Hz of the highest resolution video mode supported.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

cpqSiMonitorManufacturer 1.3.6.1.4.1.232.2.2.8.2.1.11
The manufacturer of the video display.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

cpqSiMonitorThermalCondition 1.3.6.1.4.1.232.2.2.8.2.1.12
This provides the condition of the monitor's internal temperature. This value will be one of the following: other(1) Monitor thermal fault reporting is not supported by this monitor or the Insight Agent does not recognize the status. You may need to upgrade your software. ok(2) The internal temperature is within normal limits. degraded(3) The internal temperature is outside normal operating range.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), ok(2), degraded(3)  

cpqSiMonitorOperationalCondition 1.3.6.1.4.1.232.2.2.8.2.1.13
This provides the condition of the monitor's operational features. This condition value will be one of the following: other(1) Monitor operational fault reporting is not supported by this monitor or the Insight Agent does not recognize the status. You may need to upgrade your software. ok(2) The monitor is operating within normal limits. degraded(3) The monitor is not functioning within normal operating limits. At least one of the operational features has become degraded. failed(4) The monitor is not functioning within normal operating limits. At least one of the operational features has failed causing the monitor to not be usable. The monitor should be replaced.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), ok(2), degraded(3), failed(4)  

cpqSiMonitorStatus 1.3.6.1.4.1.232.2.2.8.2.1.14
This provides the status of the monitor's fault reporting features. This status value will be one of the following: other(1) Monitor fault reporting is not supported by this monitor or the Insight Agent does not recognize the status. You may need to upgrade your software. unknown(2) The monitor status is unknown because the monitor is either in power saving mode or it has been turned off. ok(3) The monitor is operating within normal limits. thermalDegraded(4) The monitor's internal temperature is not functioning within normal operating limits. operationalFailure(5) The monitor is not functioning within normal operating limits. At least one of the operational features has failed. The monitor should be replaced.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), unknown(2), ok(3), thermalDegraded(4), operationalFailure(5)  

cpqSiHotPlugSlotSupported 1.3.6.1.4.1.232.2.2.9.1
This value specifies if this system supports the Hot Pluggable Slot feature.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), notSupported(2), supported(3)  

cpqSiHotPlugSlotCondition 1.3.6.1.4.1.232.2.2.9.2
This value specifies the overall condition of the Hot Plug Slot feature. The Hot Plug condition is set as follows: other(1) When Hot Plug Slots are not supported or condition is unknown. ok(2) If there are no hot plug slots with a condition of degraded or failed. degraded(3) If there are degraded slot entries but none failed. failed(4) If there are failed slot entries.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), ok(2), degraded(3), failed(4)  

cpqSiHotPlugSlotChangeCount 1.3.6.1.4.1.232.2.2.9.3
This value will be incremented each time a hot plug event occurs resulting in a change in the hot plug slot table.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqSiHotPlugSlotTable 1.3.6.1.4.1.232.2.2.9.4
A list of Hot Plug Slot information entries.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CpqSiHotPlugSlotEntry

cpqSiHotPlugSlotEntry 1.3.6.1.4.1.232.2.2.9.4.1
A description of a Hot Plug Slot.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  CpqSiHotPlugSlotEntry  

cpqSiHotPlugSlotChassis 1.3.6.1.4.1.232.2.2.9.4.1.1
The Chassis where this hot plug slot resides.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

cpqSiHotPlugSlotIndex 1.3.6.1.4.1.232.2.2.9.4.1.2
The slot within the chassis for this hot plug slot.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

cpqSiHotPlugSlotBoardPresent 1.3.6.1.4.1.232.2.2.9.4.1.3
This value indicates whether a board is present(2) in or absent(3) from the slot. A value of other(1) indicates the information could not be obtained.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), present(2), absent(3), presentButSuspended(4)  

cpqSiHotPlugSlotPowerState 1.3.6.1.4.1.232.2.2.9.4.1.4
This value is set to powerOn(2) when power is being supplied to the slot and powerOff(3) when power is not being supplied. A value of other(1) indicates the information could not be obtained.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), powerOn(2), powerOff(3)  

cpqSiHotPlugSlotBoardCondition 1.3.6.1.4.1.232.2.2.9.4.1.5
This value specifies the condition of the hot plug slot. The hot plug condition is set as follows: other(1) When the condition could not be determined. ok(2) The slot is powered up and operating normally. degraded(3) If the board in the slot is not fully functioning. failed(4) If the slot is failed for any reason. See the status code for more information on the failure.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), ok(2), degraded(3), failed(4)  

cpqSiHotPlugSlotErrorStatus 1.3.6.1.4.1.232.2.2.9.4.1.6
This value specifies the status of the hot plug slot. The hot plug slot status is set as follows: noError(1) The slot is operating normally. generalError(2) A general error occurred. wrongRevision(3) The revision of the replacement adapter was different from the original adapter. wrongBoard(4) The model of the replacement adapter was different from the original adapter. cannotConfig(5) The adapter could not be configured. powerFault(6) A power fault occurred for the slot. unexpectedPowerLoss(7) Power was unexpectedly lost from the slot. wrongSpeed(8) The adapter cannot be run at the current bus speed. functionlFailure(9) The adapter is not functioning correctly. This may be caused by a cabling problem.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER noError(1), generalError(2), wrongRevision(3), wrongBoard(4), cannotConfig(5), powerFault(6), unexpectedPowerLoss(7), wrongSpeed(8), functionalFailure(9)  

cpqSiHotPlugSlotHwLocation 1.3.6.1.4.1.232.2.2.9.4.1.7
A text description of the hardware location, on complex multi SBB hardware only, for the hot plug slot. A NULL string indicates that the hardware location could not be determined or is irrelevant.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

cpqSiSystemBatteryOverallCondition 1.3.6.1.4.1.232.2.2.10.1
This value specifies the overall condition of all of the system batteries. The following conditions are supported: other(1) The system does not use system batteries or the battery condition is unknown. ok(2) All System Batteries are operating OK. degraded(3) One or more of the System Batteries has degraded. The degraded battery will continue to function but should be replaced. failed(4) One of more of the System Batteries has failed. The failed battery is no longer usable. Action should be taken to replace the battery.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), ok(2), degraded(3), failed(4)  

cpqSiSysBatteryTable 1.3.6.1.4.1.232.2.2.10.2
A table of System Batteries.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CpqSiSysBatteryEntry

cpqSiSysBatteryEntry 1.3.6.1.4.1.232.2.2.10.2.1
A system battery description.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  CpqSiSysBatteryEntry  

cpqSiSysBatteryIndex 1.3.6.1.4.1.232.2.2.10.2.1.1
A unique index for this battery entry.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

cpqSiSysBatteryModel 1.3.6.1.4.1.232.2.2.10.2.1.2
The model name for this battery.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

cpqSiSysBatterySerialNum 1.3.6.1.4.1.232.2.2.10.2.1.3
The serial number for this battery.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

cpqSiSysBatteryAssetTag 1.3.6.1.4.1.232.2.2.10.2.1.4
This is the customer changeable battery identifier that is set to this system battery's serial number at the time of manufacture. The string will be empty if the battery does support this function.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

cpqSiSysBatteryManufacturer 1.3.6.1.4.1.232.2.2.10.2.1.5
The battery's manufacturer's name. The string will be empty if the battery does support this function.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

cpqSiSysBatteryDate 1.3.6.1.4.1.232.2.2.10.2.1.6
The battery's manufacture date. field octets contents range ===== ====== ======= ===== 1 1-2 year 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minute 0..59 6 7 second 0..60 (use 60 for leap-second) This field will be set to year = 0 if the agent cannot provide the module date. The hour, minute, and second field will be set to zero (0) if they are not relevant. The year field is set with the most significant octet first. The string will be empty if the battery does support this function.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OCTET STRING Size(7)  

cpqSiSysBatterySmartVersion 1.3.6.1.4.1.232.2.2.10.2.1.7
The Smart Battery Data Specification version number supported by this battery. The string will be empty if the system battery does support this function.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

cpqSiSysBatteryCondition 1.3.6.1.4.1.232.2.2.10.2.1.8
This provides the current condition of this system battery. The following status values are supported: other(1) The battery does not support condition monitoring or the Insight Agent cannot determine condition. ok(2) The battery is operating normally. No user action is required. degraded(3) The battery is degraded. The battery is still usable but should be replaced. failed(4) The battery has failed. The battery is no longer usable and should be replaced soon.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), ok(2), degraded(3), failed(4)  

cpqSiSysBatteryStatus 1.3.6.1.4.1.232.2.2.10.2.1.9
This provides the current status of the battery. The following status values are supported: other(1): This battery does not support status reporting. ok(2): The battery is operating ok. User Action: No action required. capacityDegraded(3): Significant battery degradation has occurred. The battery can no longer be fully recharged. User Action: If using multiple batteries, run the Power Conservation Utility to identify the battery location. Contact your System Administrator or Authorized Reseller to order a replacement battery. chargeFault(4): One or more batteries are not functioning properly. User Action: Make sure all batteries are operating in the recommended temperature range. Check for foreign objects in the battery slots. Remove and reinsert all batteries to resume normal battery operation. Contact your System Administrator or Authorized Reseller if you are still experiencing problems. batteryFailure(5): The battery has failed and must be replaced. User Action: Contact your System Administrator or Authorized Reseller to order a replacement battery. Recycle your old battery. For proper disposal information, refer to the documentation that came with your computer.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), ok(2), capacityDegraded(3), chargeFault(4), batteryFailure(5)  

cpqSiSysBatteryChemistry 1.3.6.1.4.1.232.2.2.10.2.1.10
The chemistry of the battery.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), unknown(2), lead-Acid(3), nickel-Cadmium(4), nickel-Metal-Hydride(5), lithium-Ion(6), zinc-Air(7), lithium-Polymer(8)  

cpqSiSysBatteryRemainingCap 1.3.6.1.4.1.232.2.2.10.2.1.11
This is a percentage of the battery's remaining capacity from its design capacity. If this attribute is not supported, 65535 is returned.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

cpqSiSysBatteryFirmwareRevision 1.3.6.1.4.1.232.2.2.10.2.1.12
This is the revision level of the firmware on the battery. If this attribute is not supported, 255 is returned.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

cpqSiSysBatteryHardwareRevision 1.3.6.1.4.1.232.2.2.10.2.1.13
This is the revision level of the hardware on the battery. If this attribute is not supported, 255 is returned.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..255  

cpqSiSysBatteryFullCap 1.3.6.1.4.1.232.2.2.10.2.1.14
This is the mWatt-Hours of the battery's Full capacity on the current charge. If this attribute is not supported, 65535 is returned.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

cpqSiSysBatteryDesignCap 1.3.6.1.4.1.232.2.2.10.2.1.15
This is the mWatt-Hours of the battery's design capacity as specified by the manufacturer. If this attribute is not supported, 65535 is returned.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

cpqSiSysBatteryHwLocation 1.3.6.1.4.1.232.2.2.10.2.1.16
A text description of the hardware location, on complex multi SBB hardware only, for the battery. A NULL string indicates that the hardware location could not be determined or is irrelevant.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

cpqSiDockingStationStatus 1.3.6.1.4.1.232.2.2.11.1
This value specifies the connection of the computer system to a docking station. The following connection states are supported: notSupported(1) This system does not interface to a docking station. docked(2) This system is connected to a docking station. undocked(3) This system is not connect to a docking station.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER notSupported(1), docked(2), undocked(3)  

cpqSiDockingStationSerialNum 1.3.6.1.4.1.232.2.2.11.2
The serial number of the docking station. The string will be empty if the docking station does not support a serial or the system does not interface to a docking station.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

cpqSiDockingStationModel 1.3.6.1.4.1.232.2.2.11.3
The model name of the docking station. The string will be empty if the docking station does not report the model name or the system does not interface to a docking station.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

cpqSiDockingStationAssetTag 1.3.6.1.4.1.232.2.2.11.4
This is a customer changeable identifier that is set to the docking station serial number at the time of manufacture. The string will be empty if the docking station does not report an asset tag or the system does not interface to a docking station.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

cpqSiFruTable 1.3.6.1.4.1.232.2.2.12.1
Table of Field Replaceable Units of system, providing inventory and asset control information. This table is referenced from logical hardware descriptions elsewhere in the MIB.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CpqSiFruEntry

cpqSiFruEntry 1.3.6.1.4.1.232.2.2.12.1.1
Each entry represents a Field Replaceable Unit (FRU) of hardware.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  CpqSiFruEntry  

cpqSiFruIndex 1.3.6.1.4.1.232.2.2.12.1.1.1
A locally-unique index value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqSiFruType 1.3.6.1.4.1.232.2.2.12.1.1.2
General category of the type of FRU that this is.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), other(2), motherBoard(3), processor(4), memoryCard(5), memoryModule(6), peripheralDevice(7), systemBusBridge(8), powerSupply(9), chassis(10), fan(11), ioCard(12)  

cpqSiFruDescr 1.3.6.1.4.1.232.2.2.12.1.1.3
More detailed description of FRU type, if known.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

cpqSiFruVendor 1.3.6.1.4.1.232.2.2.12.1.1.4
Manufacturer name or ID.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cpqSiFruPartNumber 1.3.6.1.4.1.232.2.2.12.1.1.5
Number by which this unit is orderable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cpqSiFruRevision 1.3.6.1.4.1.232.2.2.12.1.1.6
Version number of this unit. If artwork level is available, it will appear as 'Artwork: XXX' following FRU version portion.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cpqSiFruFirmwareRevision 1.3.6.1.4.1.232.2.2.12.1.1.7
The revision of the firmware, if any. Otherwise null.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cpqSiFruSerialNumber 1.3.6.1.4.1.232.2.2.12.1.1.8
The serial number of this unit's instance.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cpqSiFruAssetNo 1.3.6.1.4.1.232.2.2.12.1.1.9
The asset number for this unit. This string may be limited.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

cpqSiFruClass 1.3.6.1.4.1.232.2.2.12.1.1.10
Represents the status category of the unit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), other(2), currentBoardInSlot(3), priorBoardInSlot(4), parentBoard(5), priorParentBoard(6), priorParentSystem(7)  

cpqSiFruSlotNumber 1.3.6.1.4.1.232.2.2.12.1.1.11
Physical slot number of FRU.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cpqSiFruSubAssemblyNumber 1.3.6.1.4.1.232.2.2.12.1.1.12
Subassembly containing this FRU. From FRU V5.0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqSiFruAssemblyNumber 1.3.6.1.4.1.232.2.2.12.1.1.13
Assembly containing this FRU. From FRU V5.0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqSiFruChassisNumber 1.3.6.1.4.1.232.2.2.12.1.1.14
Chassis containing this FRU. From FRU V5.0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqSiFruPositionNumber 1.3.6.1.4.1.232.2.2.12.1.1.15
Position in Chassis to help locate FRU. From FRU V5.0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqSiFruCabinetIDNumber 1.3.6.1.4.1.232.2.2.12.1.1.16
Cabinet number containing this FRU. From FRU V5.0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqSiFruSiteLocation 1.3.6.1.4.1.232.2.2.12.1.1.17
Site code for system containing this FRU. From FRU V5.0.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqSiFruDiagStatus 1.3.6.1.4.1.232.2.2.12.1.1.18
Use system status values to describe current state of the FRU.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), ok(2), degraded(3), failed(4), disabled(5)  

cpqSiFruExtendedDiagStatus 1.3.6.1.4.1.232.2.2.12.1.1.19
Diagnostic Status value returned by Device Specific diagnostics. Usually through a diagnostic status register on the device. See product manual for bit descriptions.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqSiFruCellTablePtr 1.3.6.1.4.1.232.2.2.12.1.1.20
Index for the cell in cpqSeCellTable where this FRU is physically located.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqSiFruIOCTablePtr 1.3.6.1.4.1.232.2.2.12.1.1.21
Index for the I/O Chassis in cpqSeIOCTablePtr where this FRU is physically located
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqSiFruFileId 1.3.6.1.4.1.232.2.2.12.1.1.22
This represents the FRU file identifier
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

cpqSiFruScanRev 1.3.6.1.4.1.232.2.2.12.1.1.23
This represents FRU scan revision
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

cpqSiRackEnclosureMgrTable 1.3.6.1.4.1.232.2.2.13.1
Table of possible rack and/or enclosure based systems.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CpqSiRackEnclosureMgrEntry

cpqSiRackEnclosureMgrEntry 1.3.6.1.4.1.232.2.2.13.1.1
A entry for a rack and/or enclosure based system.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  CpqSiRackEnclosureMgrEntry  

cpqSiRackEnclosureMgrIndex 1.3.6.1.4.1.232.2.2.13.1.1.1
A locally-unique index value.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqSiRackEnclosureMgrType 1.3.6.1.4.1.232.2.2.13.1.1.2
This value specifies the type of enclosure management. other(1) When the type not be determined. noEnclosureManagement(2) The server is part of a rack/enclosure managed system, but there is no dedicated enclosure manager. enclosureManagement(3) The server is part of a rack/enclosure managed system with a dedicated enclosure manager. onboardAdminManagement(4) The server is part of a rack/enclosure managed system with a onboard Administrator.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), noEnclosureManagement(2), enclosureManagement(3), onboardAdminManagement(4)  

cpqSiRackEnclosureMgrIpAddr 1.3.6.1.4.1.232.2.2.13.1.1.3
The IP address of the rack enclosure manager. The string will be empty if the enclosure does not report the information or it could not be determined.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  


cpqSiRackEnclosureMgrCondition 1.3.6.1.4.1.232.2.2.13.1.1.5
The overall condition of the Enclosure. For more detailed status information, follow the cpqSiEnclosureMgrWebLink through the Web Management Agent interface. other(1) This is the default condition for systems when cpqSiRackEnclosureMgrType has a value of noEnclosureManagement(2). When cpqSiRackEnclosureMgrType has a value of enclosureManagement(3), this indicates the status of the enclosure manager could not be determined. ok(2) The enclosure manager is in an ok state. Follow the cpqSiRackEnclosureMgrWebLink link in the Web Management Agents to manage the enclosure. degraded(3) The enclosure manager is in a degraded state. Follow the cpqSiRackEnclosureMgrWebLink link in the Web Management Agents to manage the enclosure. failed(4) The enclosure manager is in a failed state. Follow the cpqSiRackEnclosureMgrWebLink link in the Web Management Agents to manage the enclosure.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), ok(2), degraded(3), failed(4)  

cpqSiRackEnclosureMgrSerialNumber 1.3.6.1.4.1.232.2.2.13.1.1.6
The serial number of the enclosure. The string will be empty if the enclosure does not report the information or it could not be determined.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

cpqSiRackEnclosureMgrModel 1.3.6.1.4.1.232.2.2.13.1.1.7
The model name of the enclosure. The string will be empty if it could not be determined.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString  

cpqSiRackEnclosureMgrName 1.3.6.1.4.1.232.2.2.13.1.1.8
The name of the enclosure. This name logically groups together the Blade servers installed in the same enclosure and it is shared with the other servers in the enclosure. The string will be empty if it could not be determined.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString  

cpqSiRackEnclosureMgrFwRev 1.3.6.1.4.1.232.2.2.13.1.1.9
The Firmware revision of the Enclosure Manager/Onboard Administrator. The string will be empty if it could not be determined.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString  

cpqSiRackEnclosureMgrProductID 1.3.6.1.4.1.232.2.2.13.1.1.10
The Enclosure product identifier. The string will be empty if it could not be determined.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString  

cpqSiRackEnclosureMgrUUID 1.3.6.1.4.1.232.2.2.13.1.1.11
The Enclosure unique identifier. The string will be empty if it could not be determined.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString  

cpqSiServerBladeEnclosureBayNumber 1.3.6.1.4.1.232.2.2.14.1
This value specifies the enclosure bay number occupied by the blade. In case of a blade occupying multiple bays, this will be the lowest enclosure bay number of all the bay numbers occupied by this balde
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER  

cpqSiServerBladeHeight 1.3.6.1.4.1.232.2.2.14.2
Blade height is the Blade length. unknown(1) This indicates it could not be determined. halfHeightBlade(2) This indicates a half-height server Blade. fullHeightBlade(3) This indicates a full-height server Blade.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), halfHeightBlade(2), fullHeightBlade(3)  

cpqSiServerBladeWidth 1.3.6.1.4.1.232.2.2.14.3
Width of the Blade in terms of Enclosure Bays. This pertain to the Blade side that connects to the enclosure backplane.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), singleWide(2), doubleWide(3)  

cpqSiRackName 1.3.6.1.4.1.232.2.2.15.1
The rack name. This name is used to logically group together enclosures in a rack and it is shared with other enclosures in the rack. The string will be empty if it could not be determined.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString  

cpqSiRackUUID 1.3.6.1.4.1.232.2.2.15.2
The rack unique identifier. The string will be empty if it could be determined.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString  

cpqSiMPHostName 1.3.6.1.4.1.232.2.2.16.1
The host name of the Management Processor. The string will be empty if it could not be determined.
Status: optional Access: read-only
OBJECT-TYPE    
  DisplayString  

cpqSiMPHealthStatus 1.3.6.1.4.1.232.2.2.16.2
The health status of the Management Processor.
Status: optional Access: read-only
OBJECT-TYPE    
  INTEGER unknown(1), ok(2), degraded(3), failed(4)  

cpqSiHoodRemoved 2001
System hood is removed. The hood status has been set to removed. The system's hood is not in a properly installed state. This situation may result in improper cooling of the system due to air flow changes caused by the missing hood. User Action: Replace the cover (hood), ensure the system's cover is properly installed. Verify the system is in working order.
TRAP-TYPE    

cpqSiMonitorConditionOK 2002
Fault reporting features have returned to within their normal operating range for the monitor indicated by cpqSiMonitorIndex. The monitor's condition has been set to OK. User Action: None.
TRAP-TYPE    

cpqSiMonitorConditionDegraded 2003
A fault reporting feature has exceeded normal limits for the monitor indicated by the cpqSiMonitorIndex. The monitor's condition is degraded due to the internal temperature exceeding normal operating limits. The monitor is still useable, but action should be taken to return the condition to OK. User Action: Physically check for obstructions to air flow around the monitor. Check the thermostat in the room that the system occupies. Allow the monitor to cool by turning off the monitor for 5 minutes then turn the monitor back on. After the monitor cools, another alarm indicating an improving condition, such as Monitor OK, will be issued.
TRAP-TYPE    

cpqSiMonitorConditionFailed 2004
A fault reporting feature has exceeded normal limits in the monitor indicated by the cpqSiMonitorIndex. The monitor's condition has been set to failed due to an operational feature exceeding normal operating limits. The monitor will not be useable and should be replaced. User Action: Make a note of the monitor model number and serial number. Replace the monitor. Refer to the appropriate Maintenance and Service Guide for detailed information on a component replacement.
TRAP-TYPE    

cpqSiCorrMemErrStatusDegraded 2005
Correctable memory error count has exceeded the threshold for the memory module indicated by the 'cpqSiMemErrorIndex' variable. The appropriate cpqSiMemModuleECCStatus has been set to degraded. User Action: For Desktops, the System Administrator should run the F10 Diagnostics on this system and select RAM LONG TEST. If it is determined that a module needs replacing, schedule maintenance for the system and replace the failed memory module. Refer to the appropriate Maintenance and Service Guide for detailed information on a component replacement.
TRAP-TYPE    

cpqSiCorrMemErrStatusOk 2006
Correctable memory error count is now below the threshold for the memory module indicated by the 'cpqSiMemErrorIndex' variable. The appropriate cpqSiMemModuleECCStatus has been set to ok. User Action: None.
TRAP-TYPE    

cpqSiMemConfigChange 2007
A memory configuration change has occurred. CpqSiMemConfigChangeData will indicate which memory modules slots have changed. User Action: You may want to verify a valid reason for a memory configuration to have occurred. If system issuing the alert is a Desktop running NT, the memory configuration change information is also logged in the NT System Log.
TRAP-TYPE    

cpqSiHotPlugSlotBoardRemoved 2008
Hot Plug Slot Board Removed. A Hot Plug Slot Board has been removed from the specified chassis and slot. User Action: None.
TRAP-TYPE    

cpqSiHotPlugSlotBoardInserted 2009
Hot Plug Slot Board Inserted. A Hot Plug Slot Board has been inserted into the specified chassis and slot. User Action: None.
TRAP-TYPE    

cpqSiHotPlugSlotPowerUpFailed 2010
Hot Plug Slot Board Failed Power-Up. A Hot Plug Slot Board has failed to power-up in the specified chassis and slot. User Action: Insure the board and all cables are installed correctly and the board type and revision are the same as the replaced board.
TRAP-TYPE    

cpqSiSysBatteryFailure 2011
The battery indicated by cpqSiSysBatteryIndex has failed and must be replaced. User Action: Contact your System Administrator or Authorized Reseller to order a replacement battery. Recycle your old battery. For proper disposal information, refer to the documentation that came with your computer.
TRAP-TYPE    

cpqSiSysBatteryChargingDegraded 2012
Significant battery degradation has occurred with battery indicated by cpqSiSysBatteryIndex. The battery can no longer be fully recharged. User Action: If using multiple batteries, run the Power Conservation Utility to identify the battery location. Contact your System Administrator or Authorized Reseller to order a replacement battery.
TRAP-TYPE    

cpqSiSysBatteryCalibrationError 2013
Calibration is needed with battery indicated by cpqSiSysBatteryIndex. The battery can not correctly indicate capacity. User Action: Run the Power Conservation Utility. Contact your System Administrator or Authorized Reseller to order a replacement battery.
TRAP-TYPE