CPQSERVICE-MIB

File: CPQSERVICE-MIB.mib (20755 bytes)

Imported modules

CPQHOST-MIB RFC1213-MIB RFC1155-SMI
RFC-1212 RFC-1215

Imported symbols

compaq DisplayString IpAddress
OBJECT-TYPE TRAP-TYPE sysName

Defined Values

cpqService 1.3.6.1.4.1.232.164
OBJECT IDENTIFIER    

cpqServiceMibRev 1.3.6.1.4.1.232.164.1
OBJECT IDENTIFIER    

cpqServiceIncident 1.3.6.1.4.1.232.164.2
OBJECT IDENTIFIER    

cpqServiceMibRevMajor 1.3.6.1.4.1.232.164.1.2
The Major Revision level of the MIB. A change in the major revision level represents a major change in the architecture of the MIB. A change in the major revision level may indicate a significant change in the information supported and/or the meaning of the supported information. Correct interpretation of data may require a MIB document with the same major revision level.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 1..65535  

cpqServiceMibRevMinor 1.3.6.1.4.1.232.164.1.1
The Minor Revision level of the MIB. A change in the minor revision level may represent some minor additional support, no changes to any pre-existing information has occurred.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..65535  

cpqServiceIncidentSeverity 1.3.6.1.4.1.232.164.2.1
The severity of the service incident.
Status: deprecated Access: read-only
OBJECT-TYPE    
  INTEGER important(1), informational(2)  

cpqServiceIncidentStatus 1.3.6.1.4.1.232.164.2.2
The status of the service incident.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), intransit(2), delivered(3), undelivered(4), assigned(5), closed(6), submitted-to-ISEE(7)  

cpqServiceIncidentInformation 1.3.6.1.4.1.232.164.2.3
Provides the URL to the event analysis report.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

cpqServiceIncidentEvent 1.3.6.1.4.1.232.164.2.4
Brief description of the event that initiated the service incident.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

cpqServiceIncidentUniqueID 1.3.6.1.4.1.232.164.2.5
Unique Event Analysis Identifier assigned to the incident.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

cpqServiceIncidentTimeofOriginalEvent 1.3.6.1.4.1.232.164.2.6
Time of the original event this service event relates to.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

cpqServiceIncidentSourceSystemName 1.3.6.1.4.1.232.164.2.7
Name of the system this service event relates to.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

cpqServiceIncidentIPAddessOfSource 1.3.6.1.4.1.232.164.2.8
IP Address of the system this service event relates to.
Status: mandatory Access: read-only
OBJECT-TYPE    
  IpAddress  

cpqServiceISEEIncidentInformation 1.3.6.1.4.1.232.164.2.9
This is a URL pointing to the Service Incident status in ISEE if available.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

cpqServiceIncidentIdentifier 1.3.6.1.4.1.232.164.2.10
Service Incident Identifier assigned to the incident report by the ISEE client.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

cpqServiceIncidentReceiveTrapOID 1.3.6.1.4.1.232.164.2.11
The ID of the originally received event.
Status: mandatory Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

cpqServiceIncidentFilterOID 1.3.6.1.4.1.232.164.2.12
The OID of the value that is used by the OSEM filter.
Status: deprecated Access: read-only
OBJECT-TYPE    
  OBJECT IDENTIFIER  

cpqServiceIncidentFilterValue 1.3.6.1.4.1.232.164.2.13
The value contained in the Filter OID.
Status: deprecated Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

cpqServiceRecommendedAction1 1.3.6.1.4.1.232.164.2.14
Recommended action.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

cpqServiceRecommendedAction2 1.3.6.1.4.1.232.164.2.15
Recommended action continued
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

cpqServiceRecommendedAction3 1.3.6.1.4.1.232.164.2.16
Recommended action continued
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

cpqServiceCustomerSelfRepairInstructionURL 1.3.6.1.4.1.232.164.2.17
A URL pointing to additional repair information
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

cpqServiceEventSeverity 1.3.6.1.4.1.232.164.2.18
The severity of the service incident.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER critical(1), major(2), minor(3), warning(4), informational(5)  

cpqServiceAnalyzerSystemName 1.3.6.1.4.1.232.164.2.19
Name of the system this service event was analyzed on.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

cpqServiceFRUList1 1.3.6.1.4.1.232.164.2.20
Replaceable Unit information
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

cpqServiceFRUList2 1.3.6.1.4.1.232.164.2.21
Replaceable Unit information continued
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

cpqServiceFRUList3 1.3.6.1.4.1.232.164.2.22
Replaceable Unit information continued
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

cpqServiceFRUList4 1.3.6.1.4.1.232.164.2.23
Replaceable Unit information continued
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

cpqServiceLocation1 1.3.6.1.4.1.232.164.2.24
Replaceable Unit location
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

cpqServiceLocation2 1.3.6.1.4.1.232.164.2.25
Replaceable Unit location continued
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

cpqServiceInformation 164001
This trap will be sent any time a service incident is logged or updated. A service incident is generated when it is determined that a service event has occurred based upon an analysis of system initiated event traps or an update to a service event has occurred. User Action: None Required
TRAP-TYPE    

cpqService2Information 164002
This event will be sent any time a service incident is reported. A service incident is generated when it is determined that a serviceable event has occurred based upon analysis of system-initiated events. User Action: Refer to the Recommended Action section under the event details section
TRAP-TYPE    

cpqService3Information 164003
This event will be sent any time a service incident is reported. A service incident is generated when it is determined that a serviceable event has occurred based upon analysis of system-initiated events. User Action: Refer to the Recommended Action section under the event details section
TRAP-TYPE