CPQNODE-MIB
File:
CPQNODE-MIB.mib (12595 bytes)
Imported modules
Imported symbols
Defined Values
cpqNode |
1.3.6.1.4.1.232.20 |
OBJECT IDENTIFIER |
|
|
|
cpqNodeCart |
1.3.6.1.4.1.232.20.1.1 |
The cart number to index within this chassis when cpqNodeType is CART. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
cpqNodeNode |
1.3.6.1.4.1.232.20.1.2 |
The node number to index within this chassis when cpqNodeType is NODE. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
cpqNodeType |
1.3.6.1.4.1.232.20.1.3 |
Indicates whether the event applies to a cartridge, node or switch. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
cartridge(0), node(1), switch(2), unknown(3) |
|
cpqNodeUUID |
1.3.6.1.4.1.232.20.1.4 |
Cartridge specific Unique Identitifer to indetify where the trap
came from withing the chassis. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..36) |
|
cpqNodeSerial |
1.3.6.1.4.1.232.20.1.5 |
Cartridge specific Serial Number to indetify where the trap
came from withing the chassis. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..20) |
|
cpqNodeMac1 |
1.3.6.1.4.1.232.20.1.6 |
The module date.
field octets contents
===== ====== =======
1 1-2 first byte of mac address
2 3 : separator
3 4-5 2nd byte of mac address
4 6 : separator
5 7-8 3rd byte of mac address
6 9 : separator
7 10-11 4th byte of mac address
8 12 : separator
9 13-14 5th byte of mac address
10 15 : separator
11 16-17 6th byte of mac address
12 18 : separator
First MAC address to identify the node |
Status: deprecated |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
cpqNodeMac2 |
1.3.6.1.4.1.232.20.1.7 |
The module date.
field octets contents
===== ====== =======
1 1-2 first byte of mac address
2 3 : separator
3 4-5 2nd byte of mac address
4 6 : separator
5 7-8 3rd byte of mac address
6 9 : separator
7 10-11 4th byte of mac address
8 12 : separator
9 13-14 5th byte of mac address
10 15 : separator
11 16-17 6th byte of mac address
12 18 : separator
First MAC address to identify the node |
Status: deprecated |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
cpqNodeMac3 |
1.3.6.1.4.1.232.20.1.8 |
The module date.
field octets contents
===== ====== =======
1 1-2 first byte of mac address
2 3 : separator
3 4-5 2nd byte of mac address
4 6 : separator
5 7-8 3rd byte of mac address
6 9 : separator
7 10-11 4th byte of mac address
8 12 : separator
9 13-14 5th byte of mac address
10 15 : separator
11 16-17 6th byte of mac address
12 18 : separator
First MAC address to identify the node |
Status: deprecated |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
cpqNodeMac4 |
1.3.6.1.4.1.232.20.1.9 |
The module date.
field octets contents
===== ====== =======
1 1-2 first byte of mac address
2 3 : separator
3 4-5 2nd byte of mac address
4 6 : separator
5 7-8 3rd byte of mac address
6 9 : separator
7 10-11 4th byte of mac address
8 12 : separator
9 13-14 5th byte of mac address
10 15 : separator
11 16-17 6th byte of mac address
12 18 : separator
First MAC address to identify the node |
Status: deprecated |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
cpqNodeErrorMessage |
1.3.6.1.4.1.232.20.1.10 |
Cartridge specific message defining what the error is. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..128) |
|
cpqNodeTemperatureDegraded |
23001 |
The temperature status has been set to degraded in the
specified chassis and location.
The server's temperature is outside of the normal operating
range. |
TRAP-TYPE |
|
|
|
cpqNodeTemperatureOk |
23002 |
The temperature status has been set to ok in the
specified chassis and location.
The server's temperature has returned to the normal operating
range. |
TRAP-TYPE |
|
|
|
cpqNodeTemperatureFailed |
23003 |
The temperature status has been set to degraded in the
specified chassis and location.
The server's temperature is outside of the normal operating
range. |
TRAP-TYPE |
|
|
|
cpqNodeErrorEvent |
23004 |
An error event has been received from a cartridge. The
details can be found in the error message string. |
TRAP-TYPE |
|
|
|