CPQ-TRAPS-MIB
File:
CPQ-TRAPS-MIB.mib (15629 bytes)
Imported modules
Imported symbols
Defined Types
Defined Values
mib-2 |
1.3.6.1.2.1 |
OBJECT IDENTIFIER |
|
|
|
compaq |
1.3.6.1.4.1.232 |
OBJECT IDENTIFIER |
|
|
|
compaq |
1.3.6.1.4.1.232 |
OBJECT IDENTIFIER |
|
|
|
cpqRackAssetEntry |
1.3.6.1.4.1.232.22.2.2.1.1 |
OBJECT IDENTIFIER |
|
|
|
cpqRackUid |
1.3.6.1.4.1.232.22.2.2.1.1.3 |
OBJECT IDENTIFIER |
|
|
|
cpqRackCommonEnclosureEntry |
1.3.6.1.4.1.232.22.2.3.1.1.1 |
OBJECT IDENTIFIER |
|
|
|
cpqRackNetConnectorEntry |
1.3.6.1.4.1.232.22.2.6.1.1.1 |
OBJECT IDENTIFIER |
|
|
|
cpqRackName |
1.3.6.1.4.1.232.22.2.2.1.1.2 |
OBJECT IDENTIFIER |
|
|
|
agentBscSwFileEntry |
1.3.6.1.4.1.232.161.3.1.2.1.1 |
OBJECT IDENTIFIER |
|
|
|
agentSNTP |
1.3.6.1.4.1.232.161.3.1.7 |
OBJECT IDENTIFIER |
|
|
|
agentSwitchFanEntry |
1.3.6.1.4.1.232.161.3.3.3.1.1 |
OBJECT IDENTIFIER |
|
|
|
agentSwitchTempSensorEntry |
1.3.6.1.4.1.232.161.3.3.4.1.1 |
OBJECT IDENTIFIER |
|
|
|
agentSwitchPowerSupplyEntry |
1.3.6.1.4.1.232.161.3.3.2.1.1 |
OBJECT IDENTIFIER |
|
|
|
agentSwitchCubeEntry |
1.3.6.1.4.1.232.161.3.3.1.1.1 |
OBJECT IDENTIFIER |
|
|
|
switchPostSuccess |
161011 |
The switch has successfully completed POST. |
TRAP-TYPE |
|
|
|
switchSNTPServiceUnavailable |
161015 |
A SNTP Server was configured, but no SNTP servers were found. This trap is sent once if SNTP is enabled, a SNTP server is configured, and a SNTP server could not be contacted for 10minutes from the start time. The start time will be defined as when both SNTP was enabled and a SNTP server was configured or when a SNTP server was contacted successfully. |
TRAP-TYPE |
|
|
|
switchFanOk |
161007 |
The switch fan has returned to normal operation. |
TRAP-TYPE |
|
|
|
entConfigChange |
1 |
An entConfigChange notification is generated when the value of entLastChangeTime changes. It can be utilized by an NMS to trigger logical/physical entity table maintenance polls. An agent should not generate more than one entConfigChange 'notification-event' in a given time interval (five seconds is the suggested default). A 'notification-event' is the transmission of a single trap or inform PDU to a list of notification destinations. If additional configuration changes occur within the throttling period, then notification-events for these changes should be suppressed by the agent until the current throttling period expires. At the end of a throttling period, one notification-event should be generated if any configuration changes occurred since the start of the throttling period. In such a case, another throttling period is started right away. An NMS should periodically check the value of entLastChangeTime to detect any missed entConfigChange notification-events, e.g., due to throttling or transmission loss. |
TRAP-TYPE |
|
|
|
switchTempSensorFailed |
161009 |
The switch temperature sensor indicates an over-temperature condition. |
TRAP-TYPE |
|
|
|
switchCubeTypeChange |
161014 |
Trap for connection different cube type. Customer has changed the cube type since the last boot. |
TRAP-TYPE |
|
|
|
switchLocationChange |
161013 |
The switch location has changed. The new location is defined in the variables. The trap will be sent out on the next boot |
TRAP-TYPE |
|
|
|
switchFileInvalid |
161005 |
Invalid firmware or configuration image downloaded. |
TRAP-TYPE |
|
|
|
switchTempSensorOk |
161010 |
The switch temperature sensor indicates temperature has returned to normal. |
TRAP-TYPE |
|
|
|