CISCOSB-POE-MIB

File: CISCOSB-POE-MIB.mib (13272 bytes)

Imported modules

CISCOSB-MIB SNMPv2-TC SNMPv2-SMI

Imported symbols

switch001 DisplayString TruthValue
OBJECT-TYPE MODULE-IDENTITY

Defined Types

RlPethPsePortEntry  
SEQUENCE    
  rlPethPsePortGroupIndex INTEGER
  rlPethPsePortIndex INTEGER
  rlPethPsePortOutputVoltage INTEGER
  rlPethPsePortOutputCurrent INTEGER
  rlPethPsePortOutputPower INTEGER
  rlPethPsePortPowerLimit INTEGER
  rlPethPsePortStatus INTEGER
  rlPethPsePortStatusDescription DisplayString
  rlPethPsePortOperPowerLimit INTEGER
  rlPethPsePortSupportPoePlus TruthValue
  rlPethPsePortTimeRangeName DisplayString
  rlPethPsePortOperStatus TruthValue
  rlPethPsePortMaxPowerAllocAllowed INTEGER
  rlPethPsePortSupportPoe TruthValue

RlPethMainPseEntry  
SEQUENCE    
  rlPethMainPseGroupIndex INTEGER
  rlPethMainPseSwVersion DisplayString
  rlPethMainPseHwVersion DisplayString
  rlPethMainPseHwType INTEGER
  rlPethMainPsePowerGuardBand INTEGER

RlPethPowerPseEntry  
SEQUENCE    
  rlPethPowerPseGroupIndex INTEGER
  rlPethPowerPsePower INTEGER
  rlPethPowerPseRpsPower INTEGER
  rlPethPowerPsePowerManagementMode INTEGER
  rlPethPowerPsedisconnectMethod INTEGER
  rlPethPowerPseTemperatureSensor INTEGER
  rlPethPowerPseInrushTestEnabled INTEGER
  rlPethPowerPseLegacyDisabled INTEGER

Defined Values

rlPoe 1.3.6.1.4.1.9.6.1.101.108
Add a new field in the PoE MIB to indicate Max power allocation allowed
MODULE-IDENTITY    

rlPethPsePortTable 1.3.6.1.4.1.9.6.1.101.108.1
The table listing additional information for Power Over Ethernet ports.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    RlPethPsePortEntry

rlPethPsePortEntry 1.3.6.1.4.1.9.6.1.101.108.1.1
An entry in the rlPethPsePortTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  RlPethPsePortEntry  

rlPethPsePortGroupIndex 1.3.6.1.4.1.9.6.1.101.108.1.1.1
This variable uniquely identifies the group containing the port to which a power Ethernet PSE is connected. Group means box in the stack, module in a rack and the value 1 MUST be used for non-modular devices. Furthermore, the same value MUST be used in this variable, pethMainPseGroupIndex, and pethNotificationControlGroupIndex to refer to a given box in a stack or module in the rack.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..2147483647  

rlPethPsePortIndex 1.3.6.1.4.1.9.6.1.101.108.1.1.2
This variable uniquely identifies the power Ethernet PSE port within group pethPsePortGroupIndex to which the power Ethernet PSE entry is connected.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..2147483647  

rlPethPsePortOutputVoltage 1.3.6.1.4.1.9.6.1.101.108.1.1.3
This variable indicates on the output voltage level in milli volts from rlPethPsePortIndex.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..2147483647  

rlPethPsePortOutputCurrent 1.3.6.1.4.1.9.6.1.101.108.1.1.4
This variable indicates on the output current level in milli amper from rlPethPsePortIndex.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..2147483647  

rlPethPsePortOutputPower 1.3.6.1.4.1.9.6.1.101.108.1.1.5
This variable indicates on the output power level in milli watts from rlPethPsePortIndex.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..2147483647  

rlPethPsePortPowerLimit 1.3.6.1.4.1.9.6.1.101.108.1.1.6
This variable indicates on the user configured power level in milli watts which is available from rlPethPsePortIndex.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..2147483647  

rlPethPsePortStatus 1.3.6.1.4.1.9.6.1.101.108.1.1.7
This variable indicates on the hardware status of rlPethPsePortIndex.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..2147483647  

rlPethPsePortStatusDescription 1.3.6.1.4.1.9.6.1.101.108.1.1.8
This variable indicates the description of the hardware status of rlPethPsePortIndex.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..80)  

rlPethPsePortOperPowerLimit 1.3.6.1.4.1.9.6.1.101.108.1.1.9
This variable indicates the maximum power level in milli watts which is available from rlPethPsePortIndex.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..2147483647  

rlPethPsePortSupportPoePlus 1.3.6.1.4.1.9.6.1.101.108.1.1.10
This variable indicates if the port supports poe plus.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

rlPethPsePortTimeRangeName 1.3.6.1.4.1.9.6.1.101.108.1.1.11
This variable is used to bind PoE port to time range.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..32)  

rlPethPsePortOperStatus 1.3.6.1.4.1.9.6.1.101.108.1.1.12
This Read-Only variable indicates PoE port current status affected by time range active/inactive and admin status.
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

rlPethPsePortMaxPowerAllocAllowed 1.3.6.1.4.1.9.6.1.101.108.1.1.13
This variable indicates the maximum power allocation allowed per port (including wire power loses) in milli-watts which is available from rlPethPsePortIndex.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..2147483647  

rlPethPsePortSupportPoe 1.3.6.1.4.1.9.6.1.101.108.1.1.14
This variable indicates if the port is a poe port
Status: current Access: read-only
OBJECT-TYPE    
  TruthValue  

rlPethMainPseTable 1.3.6.1.4.1.9.6.1.101.108.2
The table listing additional read - only information for Power Over Ethernet.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    RlPethMainPseEntry

rlPethMainPseEntry 1.3.6.1.4.1.9.6.1.101.108.2.1
An entry in the rlPethMainPseTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  RlPethMainPseEntry  

rlPethMainPseGroupIndex 1.3.6.1.4.1.9.6.1.101.108.2.1.1
This variable uniquely identifies the group containing the port to which a power Ethernet PSE is connected. Group means box in the stack, module in a rack and the value 1 MUST be used for non-modular devices. Furthermore, the same value MUST be used in this variable, pethMainPseGroupIndex, and pethNotificationControlGroupIndex to refer to a given box in a stack or module in the rack.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..2147483647  

rlPethMainPseSwVersion 1.3.6.1.4.1.9.6.1.101.108.2.1.2
This variable identifies the MCU SW version.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..20)  

rlPethMainPseHwVersion 1.3.6.1.4.1.9.6.1.101.108.2.1.3
This variable identifies the MCU HW version.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..20)  

rlPethMainPseHwType 1.3.6.1.4.1.9.6.1.101.108.2.1.4
This variable identifies the MCU HW type (enhanced, plus, none).
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER enhanced(1), plus(2), auto(3), nonPoe(4), enhancedPlus(5)  

rlPethMainPsePowerGuardBand 1.3.6.1.4.1.9.6.1.101.108.2.1.5
This variable identifies the guard band in [W] for not connecting additional ports.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..2147483647  

rlPethPowerPseTable 1.3.6.1.4.1.9.6.1.101.108.3
The table listing additional read-write information for Power Over Ethernet.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    RlPethPowerPseEntry

rlPethPowerPseEntry 1.3.6.1.4.1.9.6.1.101.108.3.1
An entry in the rlPethPowerPseTable.
Status: current Access: not-accessible
OBJECT-TYPE    
  RlPethPowerPseEntry  

rlPethPowerPseGroupIndex 1.3.6.1.4.1.9.6.1.101.108.3.1.1
This variable uniquely identifies the group containing the port to which a power Ethernet PSE is connected. Group means box in the stack, module in a rack and the value 1 MUST be used for non-modular devices. Furthermore, the same value MUST be used in this variable, PethPowerPseGroupIndex, and pethNotificationControlGroupIndex to refer to a given box in a stack or module in the rack.
Status: current Access: not-accessible
OBJECT-TYPE    
  INTEGER 1..8  

rlPethPowerPsePower 1.3.6.1.4.1.9.6.1.101.108.3.1.2
This variable identifies the maximum power in [W] supplied by PSE.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(0), ps1(1), ps2(2), ps3(3)  

rlPethPowerPseRpsPower 1.3.6.1.4.1.9.6.1.101.108.3.1.3
This variable identifies the maximum power in [W] supplied by PSE + RPS.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER none(0), rps1(1), rps2(2), rps3(3)  

rlPethPowerPsePowerManagementMode 1.3.6.1.4.1.9.6.1.101.108.3.1.4
This variable identifies power management mode.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER portlimit(0), classlimit(5), maxlimit(6)  

rlPethPowerPsedisconnectMethod 1.3.6.1.4.1.9.6.1.101.108.3.1.5
This variable identifies disconnect method.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER lowestpriority(0), nextport(1)  

rlPethPowerPseTemperatureSensor 1.3.6.1.4.1.9.6.1.101.108.3.1.6
This variable identifies the pd temperature sensor.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER -200..200  

rlPethPowerPseInrushTestEnabled 1.3.6.1.4.1.9.6.1.101.108.3.1.7
This variable identifies if HW inrush test will be disabled. by default HW inrush test is enabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(0), disabled(1)  

rlPethPowerPseLegacyDisabled 1.3.6.1.4.1.9.6.1.101.108.3.1.8
This variable identifies poe Legacy global configuration mode
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER enabled(0), disabled(1)