CISCO-WAN-FR-X21-MIB

File: CISCO-WAN-FR-X21-MIB.mib (28303 bytes)

Imported modules

SNMPv2-SMI SNMPv2-CONF BASIS-MIB
CISCOWAN-SMI

Imported symbols

MODULE-IDENTITY OBJECT-TYPE Integer32
MODULE-COMPLIANCE OBJECT-GROUP x21
frPortCnfX21PortGrp ciscoWan

Defined Types

X21CnfGrpEntry  
SEQUENCE    
  x21LineNum Integer32
  x21LineEnable INTEGER
  x21LineType INTEGER
  x21LineRate INTEGER
  x21LineLoopbackCommand INTEGER
  x21LineSendCode INTEGER
  x21LineLoopbackCodeDetection INTEGER
  x21ConnectorType INTEGER
  x21InvertClock INTEGER
  x21LineInterfaceType INTEGER
  x21ClkFrequencyThreshold Integer32
  serialLineRate Integer32
  serialLineRateVariation Integer32

FrPortCnfX21PortGrpEntry  
SEQUENCE    
  x21portNum Integer32
  x21portLineNum Integer32
  x21portRowStatus INTEGER
  x21portFlagsBetweenFrames Integer32
  x21portEqueueServiceRatio Integer32
  x21portSpeed Integer32
  x21portAdmin INTEGER
  x21portType INTEGER
  x21portSvcStatus INTEGER
  x21portSvcInUse INTEGER
  x21portSvcShareLcn INTEGER
  x21portSvcLcnLow Integer32
  x21portSvcLcnHigh Integer32
  x21portSvcDlciLow Integer32
  x21portSvcDlciHigh Integer32
  x21portDeleteSvcs INTEGER
  x21portIngrSvcBandW Integer32
  x21portEgrSvcBandW Integer32

X21AlmCnfGrpEntry  
SEQUENCE    
  x21AlmCnfLineNum Integer32
  x21Severity INTEGER

X21AlmGrpEntry  
SEQUENCE    
  x21AlmLineNum Integer32
  x21LineAlarmState Integer32
  x21LineEIAStatus Integer32
  x21AlarmClrButton INTEGER

Defined Values

ciscoWanFrX21MIB 1.3.6.1.4.1.351.150.49
The MIB module to configure X.21/HSSI physical and logical interfaces. This MIB module also contains alarm configuration of X.21 interfaces. Terminologies Used: HSSI : High Speed Serial Interface. The HSSI defines both electrical and physical interfaces on DTE and DCE devices. It operates at the physical layer of the OSI reference model. This provides high-speed data communication over WAN and LAN links.
MODULE-IDENTITY    

x21CnfGrp 2.1
OBJECT IDENTIFIER    

x21AlmCnfGrp 2.2
OBJECT IDENTIFIER    

x21AlmGrp 2.3
OBJECT IDENTIFIER    

x21CnfGrpTable 2.1.1
The X21 Configuration table. The table size is given by the value of x21LineNumofValidEntries.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    X21CnfGrpEntry

x21CnfGrpEntry 2.1.1.1
An entry in the X21 Configuration table.
Status: current Access: not-accessible
OBJECT-TYPE    
  X21CnfGrpEntry  

x21LineNum 2.1.1.1.1
This object is the identifier of a X.21 interface. FRSM-HS2/HS2B-HSSI supports a range from 1 to 2. FRSM-HS2B-12IN1 supports a range from 1 to 8.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..8  

x21LineEnable 2.1.1.1.2
This variable disables, enables or modifies a line 1 - disable 2 - enable 3 - modify Default is enable.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2), modify(3)  

x21LineType 2.1.1.1.3
This variable indicates the type X21 line type. The line-type affects the clock -- the DCE device always provides the clock and DTE accepts it. dteST is only applicable to V.35 interfaces Default is DTE.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER dte(1), dce(2), dteST(3)  

x21LineRate 2.1.1.1.4
This variable configures the X.21/HSSI/V.35 line-rate. Note that enumerations 51 through 108 are supported only by FRSM-HS2/HS2B card. default is r48Kbps on FRSM-HS2B-12IN1 default is r52Mbps on FRSM-HS2/HS2B-HSSI
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER r48Kbps(1), r56Kbps(2), r64Kbps(3), r112Kbps(4), r128Kbps(5), r168Kbps(6), r192Kbps(7), r224Kbps(8), r256Kbps(9), r280Kbps(10), r320Kbps(11), r336Kbps(12), r384Kbps(13), r392Kbps(14), r448Kbps(15), r512Kbps(16), r768Kbps(17), r1024Kbps(18), r1536Kbps(19), r1544Kbps(20), r1792Kbps(21), r1920Kbps(22), r1984Kbps(23), r2048Kbps(24), r3097Kbps(25), r3157Kbps(26), r4096Kbps(27), r4645Kbps(28), r4736Kbps(29), r6195Kbps(30), r6315Kbps(31), r7744Kbps(32), r7899Kbps(33), r8192Kbps(34), r9289Kbps(35), r9472Kbps(36), r10240Kbps(37), r10890Kbps(38), r11060Kbps(39), r12390Kbps(40), r12630Kbps(41), r13900Kbps(42), r14220Kbps(43), r14340Kbps(44), r15490Kbps(45), r15800Kbps(46), r16380Kbps(47), r20030Kbps(48), r24990Kbps(49), r52Mbps(50), r17370Kbps(51), r18950Kbps(52), r20530Kbps(53), r22100Kbps(54), r23680Kbps(55), r3088Kbps(56), r4632Kbps(57), r6176Kbps(58), r7720Kbps(59), r9264Kbps(60), r10808Kbps(61), r12352Kbps(62), r13896Kbps(63), r15440Kbps(64), r16984Kbps(65), r18528Kbps(66), r20072Kbps(67), r21616Kbps(68), r23160Kbps(69), r24704Kbps(70), r26248Kbps(71), r27792Kbps(72), r29336Kbps(73), r30880Kbps(74), r32424Kbps(75), r33968Kbps(76), r35512Kbps(77), r37056Kbps(78), r38600Kbps(79), r40144Kbps(80), r41688Kbps(81), r43232Kbps(82), r44776Kbps(83), r46320Kbps(84), r47864Kbps(85), r49408Kbps(86), r50952Kbps(87), r6144Kbps(88), r12288Kbps(89), r14336Kbps(90), r16384Kbps(91), r18432Kbps(92), r20480Kbps(93), r22528Kbps(94), r24576Kbps(95), r26624Kbps(96), r28672Kbps(97), r30720Kbps(98), r32768Kbps(99), r34816Kbps(100), r36864Kbps(101), r38912Kbps(102), r40960Kbps(103), r43008Kbps(104), r45056Kbps(105), r47104Kbps(106), r49152Kbps(107), r51200Kbps(108)  

x21LineLoopbackCommand 2.1.1.1.5
This variable represents the loopback state x21NoLoop Not in the loopback state. Normal traffic can be sent x21DiagnosticMetallicLoop Loopbacks the line on the back-card towards the Network. x21DiagnosticFrontcardLoop Loopbacks the line on the frontcard toward the Network. x21RemoteLoop The remote NTU is in the loop back mode. In this state, the FRSM-HS1 is sending the loopback code to remote NTU. Default is x21NoLoop. Note: Before going into one of the loopbacks the state should be x21NoLoop.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER x21NoLoop(1), x21DiagnosticMetallicLoop(2), x21DiagnosticFrontcardLoop(3), x21RemoteLoop(4), v35MetallicLoop(5)  

x21LineSendCode 2.1.1.1.6
This variable indicates what type of code is being sent across the X.21/HSSI interface by the device. The values mean: x21NoCode: No loopback. x21SendLoopACode: Start sending Loop A code. Valid only if the backcard is HSSI and the line-type is DTE. This command loops the line module of the remote device. x21SendLoopBCode: Start sending Loop B code. Valid only if the backcard is HSSI and the line-type is DTE. This command loops the digital section of the remote device. x21SendLocalLoopCode: Start sending CCITT X.21 Loopback Type 3 code. This is valid only if the backcard is X.21 type. x21SendRemoteLoopCode: Start sending CCITT X.21 Loopback Type 2 code. This is valid only if the backcard is X.21 type. x21SendUnLoopCode: Sending a loopback termination request. Valid for both HSSI and X.21 lines. To execute any of the loop-codes the x21LineLoopbackCommand should be set to x21RemoteLoop. Once the x21SendUnLoopCode succeeds the x21LineLoopbackCommand would transition back to x21NoLoop state. Default is x21NoCode.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER x21NoCode(1), x21SendLoopACode(2), x21SendLoopBCode(3), x21SendLocalLoopCode(4), x21SendRemoteLoopCode(5), x21SendUnLoopCode(6)  

x21LineLoopbackCodeDetection 2.1.1.1.7
Enable detection of line Loopback Codes. The loopback detection is implemented only in HSSI DCE mode. Default is codeDetectDisabled.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER codeDetectDisabled(1), codeDetectEnabled(2)  

x21ConnectorType 2.1.1.1.8
back card type This object is not used by FRSM-HS2/HS2B
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER x21Backcard(1), hssiBackcard(2), v35Backcard(3)  

x21InvertClock 2.1.1.1.9
This object configures two options: a) To invert the clock sent by HS1/HS2B with the TX data or not. b) If DCE,to expect the receive clock looped back from DTE or not. If DTE,to loop back the receive clock from DCE or not. nonInvertedAndNotLooped(1)- a)=dont invert, b)=dont expect rcv clock/ dont loop rcv clock invertedAndNotLooped(2) - a)=invert, b)=dont expect rcv clock/ dont loop rcv clock nonInvertedAndLooped(3) - a)=dont invert, b)=expect rcv clock/ loop rcv clock invertedAndLooped(4) - a)=invert, b)=expect rcv clock/ loop rcv clock Enums 1 and 2 are applicable for X.21/HSSI/V.35 interfaces. Enums 3 and 4 are applicable only for V.35. Default for X.21/HSSI is nonInvertedAndNotLooped(1) Default for V.35 is nonInvertedAndLooped(3) This object is not used by FRSM-HS2/FRSM-HS2B-HSSI This object is used by FRSM-HS2B-12IN1 and default values are nonInvertedAndNotLooped(1) for X.21, nonInvertedAndLooped(3) for V.35.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER nonInvertedAndNotLooped(1), invertedAndNotLooped(2), nonInvertedAndLooped(3), invertedAndLooped(4)  

x21LineInterfaceType 2.1.1.1.10
This object indicates serial interface type. Default is hssi(1). This object is not is configurable in FRSM-HS2 and FRSM-HS2B-HSSI. It will be set to hssi(1) by default for these cards This object is configurable in FRSM-H2B-12IN1. Default is v35(3).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER hssi(1), x21(2), v35(3)  

x21ClkFrequencyThreshold 2.1.1.1.11
This object indicates user configurable percentage of clock frequency, which is used by DTE clock monitoring to declare clock rate out of bound alarm. This object is valid only for X.21/v.35/HSSI DTE interfaces. This object is supported by FRSM-HS2 and FRSM-HS2/B
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..5  

serialLineRate 2.1.1.1.12
Line rate for X.21/HSSI/V.35 interfaces in bps. This object is supported only by FRSM-HS2/B card, only multiples of 1000 are accepted. Default is 48Kbps for X.21/V.35 interfaces and 51840Kbps for HSSI interface.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 48000..51840000  

serialLineRateVariation 2.1.1.1.13
This object indicates line rate variation of HSSI/X.21/V.35 DCE interfaces in ppm (parts per million). i.e. clock generated from DCE hardware interface = (serialLineRate +/- (serialLineRateVariation * 10^6)/ serialLineRate) This object is supported only by FRSM-HS2/B card
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..2147483647  

x21LineNumofValidEntries 2.1.2
The number of X.21/HSSI configuration entries (regardless of their current configuration) in the x21ConfigTable table.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..8  

frPortCnfX21PortGrpTable 1.3.6.1.4.1.351.110.5.1.1.1.3.1
The config table is for X.21/HSSI logical port interface
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    FrPortCnfX21PortGrpEntry

frPortCnfX21PortGrpEntry 1.3.6.1.4.1.351.110.5.1.1.1.3.1.1
An entry for logical port.
Status: current Access: not-accessible
OBJECT-TYPE    
  FrPortCnfX21PortGrpEntry  

x21portNum 1.3.6.1.4.1.351.110.5.1.1.1.3.1.1.1
This is logical port number. The HSSI backcard can support upto 3 ports. The X.21 back card can support 4 logical ports.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..4  

x21portLineNum 1.3.6.1.4.1.351.110.5.1.1.1.3.1.1.2
This represents the line number. On FRSM-HS1 the HSSI can support 3 lines and X.21 4 lines.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..4  

x21portRowStatus 1.3.6.1.4.1.351.110.5.1.1.1.3.1.1.3
This variable adds, deletes, or modifies the port 1- add 2 - delete 3 - modify Default is add.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER add(1), del(2), mod(3)  

x21portFlagsBetweenFrames 1.3.6.1.4.1.351.110.5.1.1.1.3.1.1.4
Number of flags transmitted between two consecutive HDLC frames. Default is 1 flag.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..10  

x21portEqueueServiceRatio 1.3.6.1.4.1.351.110.5.1.1.1.3.1.1.5
Number of times queue 1 is serviced for every time queue 2 is serviced. Default is 1.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..15  

x21portSpeed 1.3.6.1.4.1.351.110.5.1.1.1.3.1.1.6
Port speed in kbps. At present it is same as line speed.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..2147483647  

x21portAdmin 1.3.6.1.4.1.351.110.5.1.1.1.3.1.1.7
This object is used for administratively changing the status of the port. Up/down used to up and down the port. Default is the up state.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER up(1), down(2), write-Only(3)  

x21portType 1.3.6.1.4.1.351.110.5.1.1.1.3.1.1.8
This represents port type. The processing of the frames depends on the type of the port.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER frame-relay(1), frFUNI(2), frame-forward(3)  

x21portSvcStatus 1.3.6.1.4.1.351.110.5.1.1.1.3.1.1.9
This represents SVC status.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(1), enable(2)  

x21portSvcInUse 1.3.6.1.4.1.351.110.5.1.1.1.3.1.1.10
This represents port SVC in use.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER not-use(1), in-use(2)  

x21portSvcShareLcn 1.3.6.1.4.1.351.110.5.1.1.1.3.1.1.11
This represents port type.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER port-based(1), card-based(2)  

x21portSvcLcnLow 1.3.6.1.4.1.351.110.5.1.1.1.3.1.1.12
This represents low end of reserved LCN for SVC.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 16..271  

x21portSvcLcnHigh 1.3.6.1.4.1.351.110.5.1.1.1.3.1.1.13
This represents high end of reserved LCN for SVC.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 16..271  

x21portSvcDlciLow 1.3.6.1.4.1.351.110.5.1.1.1.3.1.1.14
This represents low end of reserved DLCI for SVC.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..1023  

x21portSvcDlciHigh 1.3.6.1.4.1.351.110.5.1.1.1.3.1.1.15
This represents high end of reserved DLCI for SVC.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..1023  

x21portDeleteSvcs 1.3.6.1.4.1.351.110.5.1.1.1.3.1.1.16
Setting this object to 1 indicates that all the SVC connections on the given port has to be deleted.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER delete(1), other(2)  

x21portIngrSvcBandW 1.3.6.1.4.1.351.110.5.1.1.1.3.1.1.17
This represents Ingress Bandwidth reserve for SVC.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..2147483647  

x21portEgrSvcBandW 1.3.6.1.4.1.351.110.5.1.1.1.3.1.1.18
This represents Egress Bandwidth reserve for SVC.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..2147483647  

x21AlmCnfGrpTable 2.2.1
The FRSM-HS1/HS2 interface alarm configuration table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    X21AlmCnfGrpEntry

x21AlmCnfGrpEntry 2.2.1.1
An entry in the X.21/HSSI Alarm Configuration table.
Status: current Access: not-accessible
OBJECT-TYPE    
  X21AlmCnfGrpEntry  

x21AlmCnfLineNum 2.2.1.1.1
X.21/HSSI line number. FRSM-HS2/HS2B-HSSI supports a range from 1 to 2. FRSM-HS2B-12IN1 supports a range from 1 to 8.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 1..8  

x21Severity 2.2.1.1.2
This variable is used to setup the severity of LOS(Loss of Signal) or clock mismatch alarm. Whenever the above condition arises, the FRSM-HS1/HS2/HS2B will send the alarm with appropriate status.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER minor(1), major(2), dontcare(3)  

x21AlmGrpTable 2.3.1
The X.21/HSSI interface alarm configuration table.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    X21AlmGrpEntry

x21AlmGrpEntry 2.3.1.1
An entry in the X21 Alarm table
Status: current Access: not-accessible
OBJECT-TYPE    
  X21AlmGrpEntry  

x21AlmLineNum 2.3.1.1.1
This object is the identifier (line number) of a X.21/HSSI interface. The value for this object must be same as the value of x21LineNum.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 1..8  

x21LineAlarmState 2.3.1.1.2
This variable is a bitmap of the X21 Line ALarms on the FRSM-HS1. A value of zero indicates no alarms. Itemized below are the individual bits: BitPosition Alarm ----------- ----- 0 C/I signal is OFF (also used to indicate LOS) 1 Clock rate mismatch (used in DTE mode) 2 Internal Loopback (diagnostic loopback) 3 HSSI Local LoopA (line is in loopback) 4 HSSI Local LoopB (line is in loopback) 5 Remote Loopback (line is transmitting loopcodes) 6 For V35 DTE mode, DCD and CTS both are inactive 7 For V35 DCE mode, RTS is inactive 8 No cable attached to V35 backcard 9 Wrong cable attached to V35 backcard If all the bit-states are 0s: - line is not in alarm, or - line not in loopback, or - line is transmitting any loopback codes.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..1023  

x21LineEIAStatus 2.3.1.1.3
Indicates the status of X.21/HSSI lines: 0x01 -- c-lead high 0x02 -- i-lead high 0x04 -- LC-lead high (valid only for HSSI DCE mode).
Status: current Access: read-only
OBJECT-TYPE    
  Integer32 0..10  

x21AlarmClrButton 2.3.1.1.4
This variable is used to clear all the alarms for the line. 1 = No action 2 = Clear alarm.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER noaction(1), clear(2)  

cwfX21MIBConformance 1.3.6.1.4.1.351.150.49.2
OBJECT IDENTIFIER    

cwfX21MIBGroups 1.3.6.1.4.1.351.150.49.2.1
OBJECT IDENTIFIER    

cwfX21MIBCompliances 1.3.6.1.4.1.351.150.49.2.2
OBJECT IDENTIFIER    

cwfX21Compliance 1.3.6.1.4.1.351.150.49.2.2.1
The compliance statement for objects related to Frame Relay Ports.
Status: current Access: read-write
MODULE-COMPLIANCE    

ciscoWanFrX21PortGroup 1.3.6.1.4.1.351.150.49.2.1.1
The collection of objects which are applicable for X21 ports in frame relay.
Status: current Access: read-write
OBJECT-GROUP    

ciscoWanFrX21LineGroup 1.3.6.1.4.1.351.150.49.2.1.2
The collection of objects which are related to x21 lines.
Status: current Access: read-write
OBJECT-GROUP    

ciscoWanFrX21AlarmConfGroup 1.3.6.1.4.1.351.150.49.2.1.3
The collection of objects which are related to x21 lines.
Status: current Access: read-write
OBJECT-GROUP    

ciscoWanFrX21AlarmGroup 1.3.6.1.4.1.351.150.49.2.1.4
The collection of objects which are related to x21 lines.
Status: current Access: read-write
OBJECT-GROUP