CifthTemplateEntry |
|
SEQUENCE |
|
|
|
|
cifthTemplateIndex |
CifthTemplateIndex |
|
|
cifthTemplateName |
SnmpAdminString |
|
|
cifthTemplateNotifyHoldDownType |
INTEGER |
|
|
cifthTemplateNotifyHoldDownTime |
Unsigned32 |
|
|
cifthTemplateRowStatus |
RowStatus |
|
CifthThresholdEntry |
|
SEQUENCE |
|
|
|
|
cifthThresholdIndex |
CifthThresholdIndex |
|
|
cifthThresholdDescr |
SnmpAdminString |
|
|
cifthThresholdObject |
OBJECT IDENTIFIER |
|
|
cifthThresholdSeverity |
CifthThresholdSeverity |
|
|
cifthThresholdType |
INTEGER |
|
|
cifthThresholdDirection |
INTEGER |
|
|
cifthThresholdFiredValue |
Integer32 |
|
|
cifthThresholdClearedValue |
Integer32 |
|
|
cifthThresholdSampleInterval |
Unsigned32 |
|
|
cifthThresholdApsSwitchover |
TruthValue |
|
|
cifthThresholdRowStatus |
RowStatus |
|
CifthTemplateIfAssignEntry |
|
SEQUENCE |
|
|
|
|
cifthTemplateIfAssignInterface |
InterfaceIndex |
|
|
cifthTemplateIfAssignOperStatus |
INTEGER |
|
|
cifthTemplateIfAssignRowStatus |
RowStatus |
|
CifthIfThresholdFiredEntry |
|
SEQUENCE |
|
|
|
|
cifthIfThresholdFiredTemplate |
CifthTemplateIndex |
|
|
cifthIfThresholdsFired |
CifthThresholdList |
|
|
cifthIfLastThresholdFired |
CifthThresholdIndex |
|
|
cifthIfThresholdFiredLstChange |
TimeStamp |
|
|
cifthIfThresholdFiredLstSeverity |
CifthThresholdSeverity |
|
|
cifthIfThresholdFiredMaxSeverity |
CifthThresholdSeverity |
|
cifthTemplateEntry |
1.3.6.1.4.1.9.9.218.1.1.3.1 |
An entry describing the general properties of a threshold
template.
The template is created using the cifthTemplateRowStatus
object. Prior to creating an entry in the table, the manager
should obtain a unique value of cifthTemplateIndex by reading
the cifthTemplateIndexNext object. The values of
cifthTemplateName and cifthTemplateNotifyHoldDownType must be
provided before activating the entry.
After creating an entry, thresholds can be defined for the
template by creating entries with the same value of
cifthTemplateIndex in the cifthThresholdTable. The template
can then be assigned to one or more interfaces using the
cifthTemplateIfAssignTable.
Once an entry has been activated, the value of
cifthTemplateName cannot be modified. In order to use a new
value of cifthTemplateName, a new template must be defined.
The values of cifthTemplateNotifyHoldDownType and
cifthTemplateNotifyHoldDownTime may be modified when the entry
is active. See the description clause of
cifthTemplateNotifyHoldDownType for further caveats on
modification of that object. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
CifthTemplateEntry |
|
|
cifthThresholdEntry |
1.3.6.1.4.1.9.9.218.1.1.5.1 |
An entry specifying an interface threshold used in a threshold
template.
The entry is created using the cifthThresholdRowStatus object.
The values of cifthThresholdObject, cifthThresholdSeverity,
cifthThresholdType, and cifthThresholdFiredValue must be
provided before activating the entry. If the value of
cifthTemplateNotifyHoldDownType in the cifthTemplateEntry with
the same value of cifthTemplateIndex is
'fireAndClearThresholds', then the value of
cifthThresholdClearedValue must also be provided before
activating the entry. If the value of cifthThresholdType is
other than 'rateOfIncreaseExponentXIfSpeed', then the value of
cifthThresholdSampleInterval must also be provided before
activating the entry.
The agent should not allow creation of two entries in the table
with the same values of cifthTemplateIndex,
cifthThresholdObject, cifthThresholdSeverity, and
cifthThresholdDirection.
Once an entry has been activated, the values of
cifthThresholdObject, cifthThresholdSeverity,
cifthThresholdType, and cifthThresholdDirection cannot be
modified. In order to use new values of these objects, a new
threshold must be defined. The values of cifthThresholdDescr,
cifthThresholdFiredValue, cifthThresholdClearedValue,
cifthThresholdSampleInterval, and cifthThresholdApsSwitchover
may be modified when the entry is active. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
CifthThresholdEntry |
|
|
cifthTemplateIfAssignEntry |
1.3.6.1.4.1.9.9.218.1.2.2.1 |
An entry describing the assignment of a particular threshold
template to a particular interface. The entry is created using
the cifthTemplateIfAssignRowStatus object. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
CifthTemplateIfAssignEntry |
|
|
cifthTemplateIfAssignOperStatus |
1.3.6.1.4.1.9.9.218.1.2.2.1.2 |
This object indicates whether the threshold template
identified by cifthTemplateIndex is operational on the
interface identified by cifthTemplateIfAssignInterface.
When the value of this object is 'up', this indicates that
the thresholds in this template (identified by
cifthTemplateIndex) are activated on this interface, with the
following exception: If a threshold is defined on an object
that does not have an instance for this interface, then the
threshold is not activated on this interface. If any of the
thresholds are being exceeded, then a corresponding entry
exists in the cifthIfThresholdFiredTable.
When the value of this object is 'down', this indicates that
all thresholds in the template are de-activated on this
interface and there is no corresponding entry in the
cifthIfThresholdFiredTable, regardless of whether any of the
thresholds in the template are being exceeded on this
interface.
One reason for a template not to be operational on an
interface to which it is assigned is when the interface has two
(or more) templates assigned to it that contain thresholds on
the same object with the same severity and direction, i.e.,
thresholds with the same values of cifthThresholdObject,
cifthThresholdSeverity, and cifthThresholdDirection. This may
occur when a template is assigned to the interface, or when a
threshold is added to a template that is already active on the
interface. When this occurs, the implementation may operate on
both (or all) threshold values, or it may take down one (or
more) of the templates on this interface, which is indicated by
changing the value of this object from 'up' to 'down'. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
up(1), down(2) |
|
cifthIfThresholdFiredEntry |
1.3.6.1.4.1.9.9.218.1.3.3.1 |
An entry indicating an interface that currently has one or
more threshold fired conditions based on one template. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
CifthIfThresholdFiredEntry |
|
|