File: CDM-570L.mib (12375 bytes)

Imported modules

ComtechEFData CDM-570 SNMPv2-CONF
SNMPv2-SMI

Imported symbols

comtechEFData cdm570 cdm570SystemEquipmentID
cdm570AlarmMask cdm570ODU cdm570Alarms
cdm570ODUParams cdm570Conformance OBJECT-GROUP
MODULE-COMPLIANCE NOTIFICATION-GROUP OBJECT-TYPE
NOTIFICATION-TYPE MODULE-IDENTITY

Defined Values

cdm570 1.3.6.1.4.1.6247.24
Module Identity for both CDM-570 L-Band and IF-Band Satellite Modems.
MODULE-IDENTITY    

cdm570LBUCOption 1.3.6.1.4.1.6247.24.1.1.2.7
BUC option, where: 0 = None 1 = 100 watt 2 = 150 watt
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER none(0), buc100watt(1), buc150watt(2)  

cdm570LAlarmMaskBUC 1.3.6.1.4.1.6247.24.1.2.7.9
BUC alarm mask, where: 0 = Unmasked 1 = Masked
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER unmasked(0), masked(1)  

cdm570LAlarmMaskLNB 1.3.6.1.4.1.6247.24.1.2.7.10
LNB alarm mask, where: 0 = Unmasked 1 = Masked
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER unmasked(0), masked(1)  

cdm570LBUC 1.3.6.1.4.1.6247.24.1.2.8.1
OBJECT IDENTIFIER    

cdm570LBUCDCPower 1.3.6.1.4.1.6247.24.1.2.8.1.1
BUC power control, where: 0 = Disable BUC DC Power 1 = Enable BUC DC Power
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(0), enable(1)  

cdm570LBUCFSK 1.3.6.1.4.1.6247.24.1.2.8.1.2
OBJECT IDENTIFIER    

cdm570LBUCComms 1.3.6.1.4.1.6247.24.1.2.8.1.2.1
Enables or disables communication, via the FSK link, with an externally connected Block Up Converted (BUC), where: 0 = Disabled 1 = Enabled
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

cdm570LBUCAddress 1.3.6.1.4.1.6247.24.1.2.8.1.2.2
Indicates the BUC address, between 1 and 15.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 1..15  

cdm570LBUCRFOutput 1.3.6.1.4.1.6247.24.1.2.8.1.2.3
Indicates BUC output enable, where: 0 = Off (output disabled) 1 = On (output enabled)
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(0), on(1)  

cdm570LBUC10MHzReference 1.3.6.1.4.1.6247.24.1.2.8.1.3
Enables or disables the 10 MHz frequency reference to the BUC, where: 0 = Disabled 1 = Enabled
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disabled(0), enabled(1)  

cdm570LBUCAlarm 1.3.6.1.4.1.6247.24.1.2.8.1.4
OBJECT IDENTIFIER    

cdm570LBUCHighCurrentLimit 1.3.6.1.4.1.6247.24.1.2.8.1.4.1
BUC high current limit, between 500 and 4000 mA.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 500..4000  

cdm570LBUCLowCurrentLimit 1.3.6.1.4.1.6247.24.1.2.8.1.4.2
BUC low current limit, between 0 and 3000 mA. BUC low current limit must not exceed BUC high current limit.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0..3000  

cdm570LBUCLO 1.3.6.1.4.1.6247.24.1.2.8.1.5
OBJECT IDENTIFIER    

cdm570LBUCLOFrequency 1.3.6.1.4.1.6247.24.1.2.8.1.5.1
BUC transmit LO frequency in the range of 3000 to 65000 MHz. Setting 0 disables this feature. Terminal Frequency = BUC_LO +/- Tx_Frequency (depending on LO mix).
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0 | 3000..65000  

cdm570LBUCLOMix 1.3.6.1.4.1.6247.24.1.2.8.1.5.2
BUC LO frequency mix, where: 0 = Low-side mix 1 = High-side mix
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER lowSideMix(0), highSideMix(1)  

cdm570LLNB 1.3.6.1.4.1.6247.24.1.2.8.2
OBJECT IDENTIFIER    

cdm570LLNBDCPower 1.3.6.1.4.1.6247.24.1.2.8.2.1
LNB power control, where: 0 = Off 1 = On, 13V LNB voltage 2 = On, 18V LNB voltage 3 = On, 24V LNB voltage
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER off(0), on13volts(1), on18volts(2), on24volts(3)  

cdm570LLNB10MHzReference 1.3.6.1.4.1.6247.24.1.2.8.2.2
LNB 10MHz frequency reference, where: 0 = Disable LNB 10MHz reference 1 = Enable LNB 10MHz reference
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER disable(0), enable(1)  

cdm570LLNBAlarm 1.3.6.1.4.1.6247.24.1.2.8.2.3
OBJECT IDENTIFIER    

cdm570LLNBHighCurrentLimit 1.3.6.1.4.1.6247.24.1.2.8.2.3.1
LNB upper alarm limit for current, between 50 and 600 mA.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 50..600  

cdm570LLNBLowCurrentLimit 1.3.6.1.4.1.6247.24.1.2.8.2.3.2
LNB lower alarm limit for current, between 10 and 400 mA.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 10..400  

cdm570LLNBLO 1.3.6.1.4.1.6247.24.1.2.8.2.4
OBJECT IDENTIFIER    

cdm570LLNBLOFrequency 1.3.6.1.4.1.6247.24.1.2.8.2.4.1
LNB receieve LO frequency, in the range of 3000 to 65000 MHz. Setting a 0 disables the feature. Terminal Frequency = LNB_LO +/- Rx_Frequency (depending on High/Low Mix)
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER 0 | 3000..65000  

cdm570LLNBLOMix 1.3.6.1.4.1.6247.24.1.2.8.2.4.2
LO frequency mix, where: 0 = Low-side mix 1 = High-side mix
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER lowSideMix(0), highSideMix(1)  

cdm570LODUAlarms 1.3.6.1.4.1.6247.24.1.3.1.4
ODU Faults Value Description of status parameter 0 No ODU faults 1 BUC PLL 3 BUC current 5 BUC voltage 7 LNB current 9 LNB voltage 11 BUC temperature 13 BUC checksum
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER noODUfaults(0), bucPLL(1), bucCurrent(3), bucVoltage(5), lnbCurrent(7), lnbVoltage(9), bucTemperature(11), bucChecksum(13)  

cdm570LBUCParams 1.3.6.1.4.1.6247.24.1.3.6.1
OBJECT IDENTIFIER    

cdm570LBUCCurrent 1.3.6.1.4.1.6247.24.1.3.6.1.1
Indicates the value of the BUC current, between 0 and 9999 mA. Units = mA.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..9999  

cdm570LBUCVoltage 1.3.6.1.4.1.6247.24.1.3.6.1.2
Indicates the value ofthe BUC voltage, between 0 and 64 volts in 0.1 volts. Units = 0.1 volts.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..640  

cdm570LBUCTemperature 1.3.6.1.4.1.6247.24.1.3.6.1.3
Indicates the BUC temperature in degrees Celsius. If not available, response is -99. Note: This query is only valid when FSK and BUC power are turned On.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER -99..99  

cdm570LBUCSoftwareVersion 1.3.6.1.4.1.6247.24.1.3.6.1.4
Indicates the BUC software version, between 1 and 15. If not available, response is 0.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0 | 1..15  

cdm570LBUCPLLAlarm 1.3.6.1.4.1.6247.24.1.3.6.1.5
BUC PLL lock state, where: 0 = Locked 1 = Unlocked 9 = Unavailable
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER locked(0), unlocked(1), unavailable(9)  

cdm570LBUCPowerLevel 1.3.6.1.4.1.6247.24.1.3.6.1.6
BUC output power level in 0.1 watts. Units = 0.1 watts. Returns 0 when FSK and BUC power are not enabled.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..999  

cdm570LBUCTerminalTxFrequency 1.3.6.1.4.1.6247.24.1.3.6.1.7
Terminal Tx Frequency = BUC_LO +/- Tx_Frequency (depending on LO mix) Units = 100 Hz Resolution = 100 Hz Returns 0 if BUC LO is zero.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..999999999  

cdm570LLNBParams 1.3.6.1.4.1.6247.24.1.3.6.2
OBJECT IDENTIFIER    

cdm570LLNBCurrent 1.3.6.1.4.1.6247.24.1.3.6.2.1
Indicates the value of the LNB current, between 0 and 999 mA.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..999  

cdm570LLNBVoltage 1.3.6.1.4.1.6247.24.1.3.6.2.2
Indicates the value of the LNB voltage, between 0 and 30 volts. Units = 0.1 volts If not available, response is 0.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..300  

cdm570LLNBTerminalRxFrequency 1.3.6.1.4.1.6247.24.1.3.6.2.3
Terminal Rx frequency = LNB LO +/- Rx_Frequency (depending on LO mix) Units = 100 Hz Resolution = 100 Hz Returns 0 if LNB_LO is zero.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER 0..999999999  

cdm570Notifications 1.3.6.1.4.1.6247.24.2
OBJECT IDENTIFIER    

cdm570NotificationsPrefix 1.3.6.1.4.1.6247.24.2.0
OBJECT IDENTIFIER    

cdm570LODUAlarm 1.3.6.1.4.1.6247.24.2.0.4
CDM-570L BUC and LNB ODU Alarm Trap
Status: current Access: read-only
NOTIFICATION-TYPE    

cdm570LGroups 1.3.6.1.4.1.6247.24.3.3
OBJECT IDENTIFIER    

cdm570LObjectsGroup 1.3.6.1.4.1.6247.24.3.3.1
CDM-570L Objects Group.
Status: current Access: read-only
OBJECT-GROUP    

cdm570LNotificationsGroup 1.3.6.1.4.1.6247.24.3.3.2
CDM-570L Notifications Group.
Status: current Access: read-only
NOTIFICATION-GROUP    

cdm570LCompliances 1.3.6.1.4.1.6247.24.3.4
OBJECT IDENTIFIER    

cdm570LCompliance 1.3.6.1.4.1.6247.24.3.4.1
CDM-570L Compliance.
Status: current Access: read-only
MODULE-COMPLIANCE