CADANT-DQOS-GATE-MIB

File: CADANT-DQOS-GATE-MIB.mib (46453 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC SNMPv2-CONF
DOCS-QOS3-MIB CADANT-TC CADANT-CMTS-PACKETCABLE-MIB

Imported symbols

MODULE-IDENTITY OBJECT-TYPE Integer32
Unsigned32 TEXTUAL-CONVENTION RowStatus
TruthValue DisplayString MODULE-COMPLIANCE
OBJECT-GROUP docsQosIfDirection InetAddressIPv4or6
cadPCMibObjects

Defined Types

CadDQoSSource  
The origin of the database entry
TEXTUAL-CONVENTION    
  INTEGER snmp(1), configurationFile(2), externalDatabase(3), other(4), policyServer(5), compiledIntoCode(6)  

PCReasonCode  
The reason why a call is being torn down
TEXTUAL-CONVENTION    
  INTEGER noReason(-1), normal(0), resourceReassignment(1), reservationMaintFail(2), deregistration(3), timerT0Expiry(4), timerT1Expiry(5), timerT7Expiry(6), timerT8Expiry(7), newGateForFlows(8), unspecified(127)  

SDPString  
A large (up to 1024 octets) string containing Session Description protocol for the call. Uses the same semantics as DisplayString but allows a larger size to handle the sizes allowable by the SDP protocol (see RFC2327).
TEXTUAL-CONVENTION    
  OCTET STRING Size(0..1024)  

CadDQoSGateEntry  
SEQUENCE    
  cadDQoSGateId Unsigned32
  cadDQoSGateSubscriberID InetAddressIPv4or6
  cadDQoSGateClassifierProtoID Unsigned32
  cadDQoSGateClassifierSrcIP InetAddressIPv4or6
  cadDQoSGateClassifierDestIP InetAddressIPv4or6
  cadDQoSGateClassifierSrcPort Unsigned32
  cadDQoSGateClassifierDestPort Unsigned32
  cadDQoSMgmtGateCommitNotAllowed TruthValue
  cadDQoSGateAutoCommit TruthValue
  cadDQoSGateResourceID Unsigned32
  cadDQoSGateSessionClass INTEGER
  cadDQoSGateDSField Unsigned32
  cadDQoSGateTimerT7 Unsigned32
  cadDQoSGateTimerT8 Unsigned32
  cadDQoSGateReserveRequest TruthValue
  cadDQoSGateCommited TruthValue
  cadDQoSTearFlows PCReasonCode
  cadDQoSSFID Unsigned32
  cadDQoSGateESPDupContent TruthValue
  cadDQoSGateESPSrcCCCIp InetAddressIPv4or6
  cadDQoSGateESPDfCCCIp InetAddressIPv4or6
  cadDQoSGateESPDfCCCPort Unsigned32
  cadDQoSGateESPCCCId Unsigned32
  cadDQoSGateServiceClassName DisplayString
  cadDQoSGateUsSFSchedType Unsigned32
  cadDQoSGateUsNomGrantInterval Unsigned32
  cadDQoSGateUsTolGrantJitter Unsigned32
  cadDQoSGateUsGrantsPerInterval Unsigned32
  cadDQoSGateUsUnsolitedGrantSize Unsigned32
  cadDQoSGateUsReqTransPolicy Unsigned32
  cadDQoSGateUsNomPollingInterval Unsigned32
  cadDQoSGateUsTolPollJitter Unsigned32
  cadDQoSGateUsIpToSOverride Unsigned32
  cadDQoSGateUsMaxConcatBurst Unsigned32
  cadDQoSGateDsTrafficPriority Unsigned32
  cadDQoSGateDsMaxSustainedRate Unsigned32
  cadDQoSGateDsMaxTrafBurst Unsigned32
  cadDQoSGateDsMinReservedTrafRate Unsigned32
  cadDQoSGateDsMinPacketSize Unsigned32
  cadDQoSGateDsMaxLatency Unsigned32

CadDQoSMgmtGateEntry  
SEQUENCE    
  cadDQoSMgmtGateControllerIP InetAddressIPv4or6
  cadDQoSMgmtGateRemoteGateIP InetAddressIPv4or6
  cadDQoSMgmtGateRemoteGatePort Unsigned32
  cadDQoSMgmtGateRemoteGateNoRequireGateOpen TruthValue
  cadDQoSMgmtGateRemoteGateNoSendGateOpen TruthValue
  cadDQoSMgmtGateRemoteGateID Unsigned32
  cadDQoSMgmtGateRemoteGateAlgorithm INTEGER
  cadDQoSMgmtGateRemoteGateSecurityKey OCTET STRING
  cadDQoSMgmtGateEventGenPriRKSIP InetAddressIPv4or6
  cadDQoSMgmtGateEventGenPriRKSPort Unsigned32
  cadDQoSMgmtGateEventGenBatchIndicator TruthValue
  cadDQoSMgmtGateEventGenSecRKSIP InetAddressIPv4or6
  cadDQoSMgmtGateEventGenSecRKSPort Unsigned32
  cadDQoSMgmtGateEventGenBillCorrID Unsigned32
  cadDQoSMgmtGateMediaConnCalledParty DisplayString
  cadDQoSMgmtGateMediaConnRoutingNum DisplayString
  cadDQoSMgmtGateMediaConnChargeNum DisplayString
  cadDQoSMgmtGateMediaConnLocRouteNum DisplayString
  cadDQoSMgmtGateESPDfCDCIP InetAddressIPv4or6
  cadDQoSMgmtGateESPDfCDCPort Unsigned32
  cadDQoSMgmtGateESPDupEvent TruthValue
  cadDQoSMgmtGateSDPStrings SDPString
  cadDQoSMgmtGateState INTEGER
  cadDQoSMgmtGateSource CadDQoSSource

CadDQoSAuthFlowSpecEntry  
SEQUENCE    
  cadDQoSAuthFlowSpecIdx Unsigned32
  cadDQoSAuthFlowSpecBucketDepthb Unsigned32
  cadDQoSAuthFlowSpecBucketRater Unsigned32
  cadDQoSAuthFlowSpecPeakRatep Unsigned32
  cadDQoSAuthFlowSpecMinPolicedUnitm Unsigned32
  cadDQoSAuthFlowSpecMaxPktSizeM Unsigned32
  cadDQoSAuthFlowSpecReservedRateR Unsigned32
  cadDQoSAuthFlowSpecSlackTermS Unsigned32
  cadDQoSAuthFlowSpecSubscriberID InetAddressIPv4or6

Defined Values

cadDQoSMib 1.3.6.1.4.1.4998.1.1.115.1.2
This MIB Module supplies the management objects which are specific to the PacketCable DQoS Gate client of COPS. The objects for the management of the standard COPS protocol reside in RFC2940.
MODULE-IDENTITY    

cadDQoSMibObjects 1.3.6.1.4.1.4998.1.1.115.1.2.1
OBJECT IDENTIFIER    

cadDQoSConfigBase 1.3.6.1.4.1.4998.1.1.115.1.2.1.1
OBJECT IDENTIFIER    

cadDQoSGateTable 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.1
Table of DQoS Gate Data
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CadDQoSGateEntry

cadDQoSGateEntry 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.1.1
This entry contains all of the data (except for the Authorized flow specs) for one Gate.
Status: current Access: not-accessible
OBJECT-TYPE    
  CadDQoSGateEntry  

cadDQoSGateId 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.1.1.1
The GateID is 32 bit identifier that is allocated from the local space at the CMTS where the Gate resides. Up to two gates MAY share the same Gate-ID. Typically, a Gate-ID will identify a single upstream flow and a single downstream flow, and correspond to a single Multi-media session. All gates assigned the same Gate-ID by the CMTS MUST transition together through the cadDQoSGateState.
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

cadDQoSGateSubscriberID 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.1.1.2
The Subscriber-ID identifies the subscriber (cable modem) for this service request. Its main use is to prevent various denial-of-service attacks.
Status: current Access: read-write
OBJECT-TYPE    
  InetAddressIPv4or6  

cadDQoSGateClassifierProtoID 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.1.1.3
protocol ID (see http://www.iana.org/assignments/protocol-numbers) to match in the IP header for the classifier - 0 for no match
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

cadDQoSGateClassifierSrcIP 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.1.1.4
Source IP Address to match in the IP header for the classifier
Status: current Access: read-write
OBJECT-TYPE    
  InetAddressIPv4or6  

cadDQoSGateClassifierDestIP 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.1.1.5
Destination IP Address to match in the IP header for the classifier
Status: current Access: read-write
OBJECT-TYPE    
  InetAddressIPv4or6  

cadDQoSGateClassifierSrcPort 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.1.1.6
Source port number to match in the IP header for the classifier
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

cadDQoSGateClassifierDestPort 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.1.1.7
Source port number to match in the IP header for the classifier
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

cadDQoSMgmtGateCommitNotAllowed 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.1.1.8
If cadDQoSGateSource is policyServer(5), then when this field is TRUE, then the policy is in a transient state and the policy server does not wish for this policy to be committed as it currently exists. Typically, the policy server will amend this policy to be more complete and then set this flag to FALSE.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

cadDQoSGateAutoCommit 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.1.1.9
When this flag is set, resources are immediately activated upon reservation.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

cadDQoSGateResourceID 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.1.1.17
The Resource-ID is a local 32-bit identifier that is allocated at the CMTS where the Gate resides. Any number of gates MAY share a resource-ID, and therefore share a common set of resources, with the restriction that only one of these gates in each direction have resources committed.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

cadDQoSGateSessionClass 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.1.1.18
Session class identifies the proper admission control policy or parameters to be applied for this gate.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER unspecified(0), normalVoIP(1), emergency(2)  

cadDQoSGateDSField 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.1.1.19
Access to the bandwidth and differentiated treatment is provided to packets with the appropriate encoding of bits in the field of the IP header specified for Differentiated Service. This is called the Diffserv code point (DSCP). The DS field also maintains backward compatibility with the present uses of the IP Precedence bits of the IPv4 TOS byte.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..255  

cadDQoSGateTimerT7 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.1.1.20
The CMTS MUST set the Timeout for Admitted QoS Parameters for the service flow to the value specified by this timer. The timeout for Admitted QoS Parameters limits the period of time that the CMTS must hold resources for a service flow's Admitted QoS Parameter Set while they are in excess of its Active QoS Parameter Set. See Appendix C, section C.2.2.5.7 of the DOCSIS RFI for more details on the use of this timer. In order to allow the EMTA to refresh this timer, the CMTS MUST inform the EMTA of the Timeout for Admitted QoS Parameters value in the response (i.e. in the DSA-RSP) to the EMTA's reservation request. The recommended default value of this timer is 200 seconds.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..60000  

cadDQoSGateTimerT8 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.1.1.21
The CMTS MUST set the Timeout for Active QoS Parameters for the service flow to the value specified by this timer. The Timeout for Active QoS Parameters limits the period of time resources remain unused on an active service flow. See Appendix C, section C.2.2.5.6 of the DOCSIS RFI for more details on the use of this timer. In order to allow the EMTA to refresh this timer, the CMTS MUST inform the EMTA of the Timeout for Active QoS Parameters value in the response (i.e. in the DSA-RSP) to the EMTA's reservation request. The default value of this timer is 0, which instructs the CMTS not to poll for activity on the service flow.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..60000  

cadDQoSGateReserveRequest 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.1.1.22
Flag indicating that a reservation request has been received for this gate.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

cadDQoSGateCommited 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.1.1.23
Flag indicating that a reservation request has been received for this gate.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

cadDQoSTearFlows 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.1.1.24
Enumeration indicating whether the Flows for this Gate are to be torn down. If set to anything other than noReason by the CAM, then the flows have been torn down for the reason specified and the gate must update itself. If set to anything other than noReason by the gate state machine, then it is a command to the CAM to tear down and delete the flows.
Status: current Access: read-write
OBJECT-TYPE    
  PCReasonCode  

cadDQoSGateESPDupContent 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.1.1.25
If set, CMTS MUST send a duplicate copy of all packets matching the classifier(s) for this gate to the DF-IP-Address-for-CCC.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

cadDQoSGateESPDfCCCIp 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.1.1.26
DF-IP-Address-for-CCC is the address of the Electronic Surveillance Delivery Function to whom the duplicated call content packets are to be sent.
Status: current Access: read-write
OBJECT-TYPE    
  InetAddressIPv4or6  

cadDQoSGateESPDfCCCPort 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.1.1.27
DF-Port-for-CCC is the port number of the Electronic Surveillance Delivery Function to whom the duplicated call content packets are to be sent.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

cadDQoSSFID 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.1.1.28
Service flow ID for this gate ID and flow direction
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

cadDQoSGateESPCCCId 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.1.1.29
CCC-ID is the call connection channel identifier to be used by the Elecronic Surveillance Delivery Function to correlate call content packets.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

cadDQoSGateESPSrcCCCIp 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.1.1.30
This is the source IP address of packets sent to the Electronic Surveillance Delivery Function to whom the duplicated call content packets are to be sent.
Status: current Access: read-write
OBJECT-TYPE    
  InetAddressIPv4or6  

cadDQoSGateServiceClassName 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.1.1.31
Service Class Name. DOCSIS specifies that the maximum size is 15 printable ASCII characters with a terminating zero. The terminating zero is not represented in this DisplayString syntax object.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(1..15)  

cadDQoSGateUsSFSchedType 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.1.1.32
Upstream Service Flows Scheduling Type (e.g. UGS)
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

cadDQoSGateUsNomGrantInterval 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.1.1.33
Upstream Nominal Grant Interval
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

cadDQoSGateUsTolGrantJitter 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.1.1.34
Upstream Tolerated Grant Jitter
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

cadDQoSGateUsGrantsPerInterval 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.1.1.35
Upstream Grants Per Interval
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

cadDQoSGateUsUnsolitedGrantSize 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.1.1.36
Upstream Unsolicited Grant Size
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

cadDQoSGateUsReqTransPolicy 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.1.1.37
Upstream Request Transmission Policy
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

cadDQoSGateUsNomPollingInterval 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.1.1.38
Upstream Nominal Polling Interval
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

cadDQoSGateUsTolPollJitter 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.1.1.39
Upstream Tolerated Poll Jitter
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

cadDQoSGateUsIpToSOverride 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.1.1.40
Upstream IP Type Of Service Override
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

cadDQoSGateUsMaxConcatBurst 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.1.1.41
Upstream Maximum Concatenated Burst
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

cadDQoSGateDsTrafficPriority 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.1.1.42
Downstream Traffic Priority
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

cadDQoSGateDsMaxSustainedRate 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.1.1.43
Downstream Maximum Sustained Traffic Rate
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

cadDQoSGateDsMaxTrafBurst 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.1.1.44
Downstream Maximum Traffic Burst
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

cadDQoSGateDsMinReservedTrafRate 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.1.1.45
Downstream Minimum Reserved Traffic Rate
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

cadDQoSGateDsMinPacketSize 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.1.1.46
Downstream Minimum Reserved Rate Packet Size
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

cadDQoSGateDsMaxLatency 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.1.1.47
Downstream Maximum Latency
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

cadDQoSMgmtGateTable 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.2
Table of DQoS Gate Data that is not needed on the CAM.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CadDQoSMgmtGateEntry

cadDQoSMgmtGateEntry 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.2.1
This entry contains all of the data (except for the Authorized flow specs) for one Gate.
Status: current Access: not-accessible
OBJECT-TYPE    
  CadDQoSMgmtGateEntry  

cadDQoSMgmtGateControllerIP 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.2.1.1
IP Address of the Gate Controller which sourced this gate. If gate was created from another source, this field is 0.
Status: current Access: read-write
OBJECT-TYPE    
  InetAddressIPv4or6  

cadDQoSMgmtGateRemoteGateIP 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.2.1.2
IP Address for remote Gate coordinator
Status: current Access: read-write
OBJECT-TYPE    
  InetAddressIPv4or6  

cadDQoSMgmtGateRemoteGatePort 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.2.1.3
Port number of remote Gate coordinator
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

cadDQoSMgmtGateRemoteGateNoRequireGateOpen 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.2.1.4
When this flag is set, the CMTS MUST not expect a Gate-Open message from a remote gate coordinator.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

cadDQoSMgmtGateRemoteGateNoSendGateOpen 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.2.1.5
When this flag is set, the CMTS MUST not send a Gate-Open message to a remote gate coordinator.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

cadDQoSMgmtGateRemoteGateID 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.2.1.6
Gate-ID used by remote gate coordinator.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

cadDQoSMgmtGateRemoteGateAlgorithm 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.2.1.7
Authentication algorithm for Gate Coordination messages
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER md5BasedMac(100)  

cadDQoSMgmtGateRemoteGateSecurityKey 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.2.1.8
A variable length key used in producing the authentication check in the gate coordination messages
Status: current Access: read-write
OBJECT-TYPE    
  OCTET STRING Size(0..128)  

cadDQoSMgmtGateEventGenPriRKSIP 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.2.1.9
Primary-Record-Keeping-Server-IP-Address is the address of the record keeper to whom event records are sent.
Status: current Access: read-write
OBJECT-TYPE    
  InetAddressIPv4or6  

cadDQoSMgmtGateEventGenPriRKSPort 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.2.1.10
Primary-Record-Keeping-Server-Port is the port number of the record keeper to whom event records are sent.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

cadDQoSMgmtGateEventGenBatchIndicator 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.2.1.11
If set, the CMTS MUST accumulate event records as part of a batch file and send to Record Keeping Server at periodic intervals. If clear, the CMTS MUST send the event records to the Record Keeping Server in real-time.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

cadDQoSMgmtGateEventGenSecRKSIP 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.2.1.12
Secondary-Record-Keeping-Server-IP-Address is the address of the secondary record keeper to whom records are sent if the primary record keeping server is unavailable.
Status: current Access: read-write
OBJECT-TYPE    
  InetAddressIPv4or6  

cadDQoSMgmtGateEventGenSecRKSPort 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.2.1.13
Secondary-Record-Keeping-Server-Port is the port number of the record keeper to whom event records are sent if the primary record keeping server is unavailable.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

cadDQoSMgmtGateEventGenBillCorrID 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.2.1.14
Billing-Correlation-ID is the identifier assigned by the CMS for all records related to this session.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

cadDQoSMgmtGateMediaConnCalledParty 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.2.1.15
E.164 formatted address specifying the actual dialed digits of the number of the terminating party. This field is a space-padded ASCII character string.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..20)  

cadDQoSMgmtGateMediaConnRoutingNum 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.2.1.16
E.164 formatted address specifying the routable number of the terminating party. This field is a space-padded ASCII character string.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..20)  

cadDQoSMgmtGateMediaConnChargeNum 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.2.1.17
E.164 formatted address specifying the number of the party to be charged. This field is a space-padded ASCII character string.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..20)  

cadDQoSMgmtGateMediaConnLocRouteNum 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.2.1.18
E.164 formatted address for local number portability use. This field is a space-padded ASCII character string.
Status: current Access: read-write
OBJECT-TYPE    
  DisplayString Size(0..20)  

cadDQoSMgmtGateESPDfCDCIP 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.2.1.19
DF-IP-Address-for-CDC is the IP address of the Electronic Surveillance Delivery Function to whom the duplicated event messages are to be sent.
Status: current Access: read-write
OBJECT-TYPE    
  InetAddressIPv4or6  

cadDQoSMgmtGateESPDfCDCPort 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.2.1.20
DF-Port-for-CDC is the port number of the Electronic Surveillance Delivery Function to whom the duplicated event messages are to be sent.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

cadDQoSMgmtGateESPDupEvent 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.2.1.21
If set, CMTS MUST send a duplicate copy of all event messages related to this gate (e.g. QoS-Start, QoS-Stop, and possibly Call-Answer and Call-Disconnect) to the DF-IP-Address-for-CDC.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

cadDQoSMgmtGateSDPStrings 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.2.1.25
SDP-strings is the Session Description (SDP) of the upstream packet stream, followed by a NULL octet, followed by the Session Description (SDP) of the downstream packet stream. Sufficient padding of NULL octets is appended to make the total length a multiple of four octets.
Status: current Access: read-write
OBJECT-TYPE    
  SDPString  

cadDQoSMgmtGateState 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.2.1.26
This is the current state of the Gate as defined in the Gate Transition Diagram of section 5.1.4 of [pkt-sp-dqos-i02-000818]. Allocated - The initial state of a gate created at the request of the GC Authorized - GC has authorized the flow with resource limits defined Reserved - Resources have been reserved for the flow Remote-Committed - Transient state in which remote CMTS has committed the gate and a Gate-Open message has been received by this CMTS Local-Committed - Transient state in which this CMTS has committed the resources for this gate Committed - Resources are being used
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER allocated(1), authorized(2), reserved(3), remoteCommitted(4), localCommitted(5), committed(6)  

cadDQoSMgmtGateSource 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.2.1.27
This object indicates how the policy reached the CMTS. Other means that it originated from a source not identified above.
Status: current Access: read-write
OBJECT-TYPE    
  CadDQoSSource  

cadDQoSAuthFlowSpecTable 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.3
The Authorized flow specification describes the envelope that the data flow is allowed to use. Issues such as subscribed level of service, account state, etc. are components that may affect the authorized envelope. There is a one-to-many mapping between Gates and authorized flow specifications. However, only one authorized flow spec may be in effect at a time for each Gate.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    CadDQoSAuthFlowSpecEntry

cadDQoSAuthFlowSpecEntry 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.3.1
This entry contains one row in the table.
Status: current Access: not-accessible
OBJECT-TYPE    
  CadDQoSAuthFlowSpecEntry  

cadDQoSAuthFlowSpecIdx 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.3.1.1
Index of flow specification within Gate
Status: current Access: not-accessible
OBJECT-TYPE    
  Unsigned32  

cadDQoSAuthFlowSpecBucketDepthb 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.3.1.2
Parameter 'b' in TSpec leaky bucket description. The token bucket size controls the maximum amount of data that the flow can send at the peak rate. More formally, if the token bucket size is 'b' and the token bucket rate is 'r', over any arbitrarily chosen interval T in the life of the flow, the amount of data that the flow sends cannot have exceeded b + (r * T) bytes. The bucket size limits how many credits the flow may store. When the bucket is full, new credits are discarded.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

cadDQoSAuthFlowSpecBucketRater 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.3.1.3
Parameter 'r' in TSpec leaky bucket description. The token bucket rate is the rate at which credits are placed into an imaginary token bucket. For each flow, a separate bucket is maintained. To send a packet over the flow, a host must remove a number of credits equal to the size of the packet from the token bucket. If there are not enough credits, the host must wait until enough credits accumulate in the bucket.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

cadDQoSAuthFlowSpecPeakRatep 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.3.1.4
Parameter 'p' in TSpec leaky bucket description. The maximum transmission rate limits how fast packets may be sent back to back from the host. Consider that if the token bucket is full, it is possible for the flow to send a series of back-to-back packets equal to the size of the token bucket. At all times, 'p' MUST be greater than or equal to the token bucket rate, 'r'.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

cadDQoSAuthFlowSpecMinPolicedUnitm 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.3.1.5
Parameter 'm' in TSpec leaky bucket description. All IP datagrams less than size 'm' will be counted, when policed and tested for conformance to the TSpec, as being of size 'm'. This is the smallest size packet that the source will generate.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

cadDQoSAuthFlowSpecMaxPktSizeM 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.3.1.6
Parameter 'M' in TSpec leaky bucket description. This is the maximum packet size (including IP and header layers) that can be generated by the source.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

cadDQoSAuthFlowSpecReservedRateR 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.3.1.7
Parameter 'R' in RSpec. A service accepting an invocation request may be thought of as entering into a contract to provide the service described by the RSpec as long as the flow's traffic continues to be described by the TSpec. This is the policed, reserved transmission flow rate toward the destination.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

cadDQoSAuthFlowSpecSlackTermS 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.3.1.8
Parameter 'S' in RSpec. This is the maximum amount of slack (in microseconds) that can be added to the inherent delay to produce an acceptable delay bound.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32  

cadDQoSAuthFlowSpecSubscriberID 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.3.1.9
The Subscriber-ID identifies the subscriber (cable modem) for this service request. Its main use is to prevent various denial-of-service attacks.
Status: current Access: read-write
OBJECT-TYPE    
  InetAddressIPv4or6  

cadDQoSTimerT0 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.4
This timer is implemented in the CMTS in the Gate state machine, and limits the period of time that a gate may be allocated without the gate parameters being set. This enables the CMTS to recover the gate-ID resources when the Call Management System fails to complete the signaling sequence for a new session. The default value of this timer is 30 seconds. This timer has a range of 1 to 60 seconds.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 1..60  

cadDQoSTimerT1 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.5
This timer is implemented in the CMTS in the Gate state machine, and limits the period of time that may elapse between the authorization and a commit is performed. This timer is started whenever a Gate is established. This timer is reset whenever a Commit operation is performed on the resources authorized by the gate. Timer-T1 MUST be set to the value given in the GATE-SET message. If the value given in the GATE-SET message is zero, then Timer-T1 MUST be set to a provisionable default value. The default value of this timer is 250 seconds.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..600  

cadDQoSTimerT2 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.6
This timer is implemented in the CMTS in the Gate state machine, and limits the time in the transient states of gate coordination. This timer is long enough to accommodate loss and retransmission of Gate coordination messages, but is short enough to not allow significant theft of service. Timer-T2 MUST be set to the value given in the GATE-SET message. If the value given in the GATE-SET message is zero, then Timer-T2 MUST be set to a provisionable default value. The default value of this default is 2 seconds.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 0..60  

cadDQoSTimerT3 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.7
This timer is implemented in the MTA or CMTS in the handling of RSVP reservations. It controls the total time that can elapse before the RSVP retransmit process gives up without receiving an acknowledgement in the presence of network loss. It is short enough to recover quickly from lost messages and not significantly impact the post-dial delay, but is long enough to allow the CMTS to acknowledge the request and all intermediate routers in the customer network. The default value of this timer is 4 seconds.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 5..50  

cadDQoSTimerT4 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.8
This timer is implemented in the MTA in the handling of COMMIT messages. It controls the retransmission of COMMIT messages that may have been lost by the network. It is short enough to recover quickly from lost commit requests and not significantly impact the post-pickup delay, but is long enough to allow processing of the COMMIT request at the CMTS. The default value of this timer is 500ms.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 1..10  

cadDQoSTimerT5 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.9
This timer is implemented in the CMTS (and CMTS-proxy) in the gate coordination processing. It controls the retransmission of GATE-OPEN and GATE-CLOSE messages that may have been lost by the network. It is short enough to recover quickly from lost gate coordination messages, but long enough to allow processing of the gate coordination message at the CMTS or CMTS-proxy. This timer interacts in the case of GATE-OPEN with Timer-T2, and SHOULD be significantly smaller than Timer-T2. The default value of this timer is 500ms.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 1..10  

cadDQoSTimerT6 1.3.6.1.4.1.4998.1.1.115.1.2.1.1.10
This timer is implemented in the MTA or CMTS in the handling of RSVP reservations. It controls the initial delay used by the RSVP retransmit procedure. The default value of this timer is 500ms.
Status: current Access: read-write
OBJECT-TYPE    
  Unsigned32 1..10