BTI7800-NOTIFICATIONS-MIB

File: BTI7800-NOTIFICATIONS-MIB.mib (73155 bytes)

Imported modules

SNMPv2-SMI SNMPv2-TC

Imported symbols

enterprises MODULE-IDENTITY OBJECT-TYPE
NOTIFICATION-TYPE TEXTUAL-CONVENTION DateAndTime
TruthValue DisplayString

Defined Types

String  
xs:string
TEXTUAL-CONVENTION    
  OCTET STRING  

Severity  
Tok_String
TEXTUAL-CONVENTION    
  INTEGER critical(1), major(2), minor(3), not-alarmed(4), not-reported(5)  

ConditionCode  
Tok_String
TEXTUAL-CONVENTION    
  INTEGER eqptMiss(1), eqptUnkn(2), eqptMism(3), eqptFail(4), eqptDgrd(5), eqptComm(6), upgr(7), lpbk(8), los(9), lof(10), loSync(11), lola(12), lom(13), tim(14), sd(15), bdi(16), pyldMism(17), odtgMism(18), ais-l(19), ms-ais(20), otu-ais(21), odu-ais(22), lck(23), oci(24), highBer(25), lf(26), rf(27), rdi-l(28), ms-rdi(29), oprHighTh(30), oprLowTh(31), optHighTh(32), optLowTh(33), laserTempHighTh(34), laserTempLowTh(35), laserFail(36), cfgUnsupp(37), cfgFail(38), lolightRx(39), lolightTx(40), feim(41), feci(42), contComS(43), contComE(44), loSpecRx(45), tLossRxHt(46), iaocp(47), iaocm(48), iaocb(49), apsd(50), pmi(51), uneqO(52), aisO(53), posRx(54), posTx(55), obros(56), chnDfc(57), replUnitDegrade(58), cnxMea(59), cnxVldTmout(60), posRxHigh(61), posRxLow(62), oprHighFail(63), obrHt(64), apr(65), modTempHighTh(66), modTempLowTh(67), modTempShutdown(68), envTempHighTh(69), envTempLowTh(70), envTempFail(71), envVoltHighTh(72), envVoltLowTh(73), envVoltFail(74), scmNmiDown(75), scmNoNmConn(76), eqptLatchOpen(77), powerAbsent(78), fanSpeedLowTh(79), nonCoLocatedController(80), preFecBerTh(81), firmUpgrdReqd(82), otuBerTh(83), oduBerTh(84), pcsBerTh(85), berTh-s(86), berTh-l(87), rs-berTh(88), ms-berTh(89), oneCableDisconnected(90), envCurrentHighTh(91), envCurrentLowTh(92), prbs(93), forced(94), lockout(95), tLossRxLt(96), omsBdi(97), ochAis(98), ochRdi(99), ochUeq(100), ochOci(101), defRDICCM(102), defMACStatus(103), defRemoteCCM(104), defErrorCCM(105), defXconCCM(106), defBfdDown(107), lf-tx(108), apsData(109), omsAis(110), isisDbOvrld(111), isisXDown(112), isisAdjDown(113), isisAdjRejected(114), rsvpAdjDown(115), diskHighUsage(116), memHighUsage(117), invUnknown(118), airfilterAbsense(119), tx-msais(120), tx-msrdi(121), tx-aisl(122), tx-rdil(123), tx-rf(124), tx-oduAis(125), tx-oduLck(126), tx-oduOci(127), tx-opuCsf(128), firmUpgrdInProg(129), firmUpgrdFail(130), partitionFault(131), oom(132), lolck(133), inventoryUnsupp(134)  

Defined Values

bTI7800-NOTIFICATIONS-MIB 1.3.6.1.4.1.18070.2.9.2
The bti7800-conditions submodule defines the data modeling that supports the retrieval of active alarms and conditions on the BTI7800 system.
MODULE-IDENTITY    

notificationObjects 1.3.6.1.4.1.18070.2.9.2.1
OBJECT IDENTIFIER    

variables 1.3.6.1.4.1.18070.2.9.2.1.1
OBJECT IDENTIFIER    

entityName 1.3.6.1.4.1.18070.2.9.2.1.1.1
The entityName identifies the system-unique name of the entity against which the condition is raised.
Status: current Access: read-write
OBJECT-TYPE    
  String  

code 1.3.6.1.4.1.18070.2.9.2.1.1.2
Identifies the type of condition raised.
Status: current Access: read-write
OBJECT-TYPE    
  ConditionCode  

reportType 1.3.6.1.4.1.18070.2.9.2.1.1.3
If set to non-alarmed, the list entry is a non-alarmed condition. If set to alarmed, the entry is an alarmed condition.
Status: current Access: read-write
OBJECT-TYPE    
  INTEGER non-alarmed(1), alarmed(2)  

timeStamp 1.3.6.1.4.1.18070.2.9.2.1.1.4
The date and time at which the condition became active.
Status: current Access: read-write
OBJECT-TYPE    
  DateAndTime  

severity 1.3.6.1.4.1.18070.2.9.2.1.1.5
The severity level of the condition.
Status: current Access: read-write
OBJECT-TYPE    
  Severity  

serviceAffecting 1.3.6.1.4.1.18070.2.9.2.1.1.6
If true, the condition is known to disrupt the normal service provided by the entity.
Status: current Access: read-write
OBJECT-TYPE    
  TruthValue  

description 1.3.6.1.4.1.18070.2.9.2.1.1.7
Provides a description of the condition raised that may include context specific information.
Status: current Access: read-write
OBJECT-TYPE    
  String  

notifications 1.3.6.1.4.1.18070.2.9.2.1.2
OBJECT IDENTIFIER    

traps 1.3.6.1.4.1.18070.2.9.2.1.2.1
OBJECT IDENTIFIER    

eqptMissRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.1
Equipment Missing Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

eqptMissClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.2
Equipment Missing Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

eqptUnknRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.3
Equipment Unknown Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

eqptUnknClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.4
Equipment Unknown Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

eqptMismRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.5
Equipment Mismatch Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

eqptMismClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.6
Equipment Mismatch Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

eqptFailRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.7
Equipment Failed Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

eqptFailClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.8
Equipment Failed Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

eqptDgrdRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.9
Equipment Degrade Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

eqptDgrdClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.10
Equipment Degrade Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

eqptCommRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.11
Equipment Comms Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

eqptCommClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.12
Equipment Comms Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

upgrRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.13
Upgrade Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

upgrClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.14
Upgrade Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

lpbkRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.15
Loopback Operated Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

lpbkClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.16
Loopback Operated Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

losRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.17
Loss of Signal Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

losClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.18
Loss of Signal Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

lofRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.19
Loss of Frame Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

lofClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.20
Loss of Frame Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

loSyncRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.21
Loss of Synchronization Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

loSyncClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.22
Loss of Synchronization Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

lolaRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.23
Loss of Lane Alignment Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

lolaClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.24
Loss of Lane Alignment Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

lomRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.25
Loss of Multiframe Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

lomClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.26
Loss of Multiframe Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

timRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.27
Trace Identifier Mismatch Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

timClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.28
Trace Identifier Mismatch Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

sdRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.29
Signal Degrade Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

sdClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.30
Signal Degrade Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

bdiRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.31
Backward Defect Indication Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

bdiClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.32
Backward Defect Indication Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

pyldMismRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.33
Payload Mismatch Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

pyldMismClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.34
Payload Mismatch Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

odtgMismRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.35
ODTG Mismatch Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

odtgMismClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.36
ODTG Mismatch Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

ais-lRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.37
Alarm Indication Signal, Line Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

ais-lClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.38
Alarm Indication Signal, Line Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

ms-aisRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.39
Multiplex Section Alarm Indication Signal Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

ms-aisClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.40
Multiplex Section Alarm Indication Signal Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

otu-aisRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.41
OTU Alarm Indication Signal Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

otu-aisClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.42
OTU Alarm Indication Signal Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

odu-aisRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.43
ODU Alarm Indication Signal Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

odu-aisClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.44
ODU Alarm Indication Signal Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

lckRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.45
ODU Locked Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

lckClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.46
ODU Locked Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

ociRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.47
ODU Open Connection Indication Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

ociClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.48
ODU Open Connection Indication Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

highBerRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.49
High Bite Error Ratio Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

highBerClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.50
High Bit Error Ratio Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

lfRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.51
Local Fault Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

lfClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.52
Local Fault Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

rfRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.53
Remote Fault Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

rfClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.54
Remote Fault Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

rdi-lRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.55
Remote Defect Indication, Line Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

rdi-lClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.56
Remote Defect Indication, Line Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

ms-rdiRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.57
Multiplex Section Remote Defect Indication Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

ms-rdiClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.58
Multiplex Section Remote Defect Indication Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

oprHighThRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.59
Optical Power Rx High Threshold Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

oprHighThClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.60
Optical Power Rx High Threshold Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

oprLowThRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.61
Optical Power Rx Low Threshold Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

oprLowThClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.62
Optical Power Rx Low Threshold Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

optHighThRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.63
Optical Power Tx High Threshold Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

optHighThClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.64
Optical Power Tx High Threshold Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

optLowThRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.65
Optical Power Tx Low Threshold Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

optLowThClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.66
Optical Power Tx Low Threshold Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

laserTempHighThRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.67
Tx Laser Above High Temperature Threshold Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

laserTempHighThClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.68
Tx Laser Above High Temperature Threshold Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

laserTempLowThRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.69
Tx Laser Below Low Temperature Threshold Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

laserTempLowThClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.70
Tx Laser Below Low Temperature Threshold Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

laserFailRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.71
Tx Laser Fail Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

laserFailClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.72
Tx Laser Fail Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

cfgUnsuppRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.73
Configuration Unsupported Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

cfgUnsuppClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.74
Configuration Unsupported Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

cfgFailRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.75
Configuration Failure Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

cfgFailClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.76
Configuration Failure Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

lolightRxRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.77
Loss of light, receive Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

lolightRxClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.78
Loss of light, receive Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

lolightTxRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.79
Loss of light, transmit Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

lolightTxClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.80
Loss of light, transmit Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

feimRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.81
Far-end node identification mismatch Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

feimClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.82
Far-end node identification mismatch Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

feciRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.83
Far-end node configuration mismatch Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

feciClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.84
Far-end node configuration mismatch Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

contComSRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.85
Control comms failure, span section Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

contComSClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.86
Control comms failure, span section Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

contComERaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.87
Control comms failure, eqlz. section Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

contComEClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.88
Control comms failure, eqlz. section Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

loSpecRxRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.89
Loss out of specification, receive Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

loSpecRxClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.90
Loss out of specification, receive Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

tLossRxHtRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.91
Loss high threshold exceeded, receive Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

tLossRxHtClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.92
Loss high threshold exceeded, receive Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

iaocpRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.93
Invalid pre-amplifier operating cfg Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

iaocpClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.94
Invalid pre-amplifier operating cfg Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

iaocmRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.95
Invalid mid-amplifier operating cfg Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

iaocmClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.96
Invalid mid-amplifier operating cfg Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

iaocbRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.97
Invalid boost-amp. operating cfg Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

iaocbClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.98
Invalid boost-amp. operating cfg Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

apsdRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.99
Automatic power shutdown Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

apsdClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.100
Automatic power shutdown Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

pmiRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.101
Payload missing indication Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

pmiClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.102
Payload missing indication Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

uneqORaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.103
Optical channel unequipped Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

uneqOClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.104
Optical channel unequipped Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

aisORaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.105
Alarm indication signal, optical Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

aisOClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.106
Alarm indication signal, optical Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

posRxRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.107
Power out of specification, receive Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

posRxClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.108
Power out of specification, receive Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

posTxRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.109
Power out of specification, transmit Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

posTxClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.110
Power out of specification, transmit Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

obrosRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.111
Optical back reflection out of spec Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

obrosClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.112
Optical back reflection out of spec Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

chnDfcRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.113
Channel count deficiency Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

chnDfcClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.114
Channel count deficiency Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

replUnitDegradeRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.115
Replaceable unit degrade Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

replUnitDegradeClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.116
Replaceable unit degrade Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

cnxMeaRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.117
Connection Mismatch Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

cnxMeaClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.118
Connection Mismatch Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

cnxVldTmoutRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.119
Connection Validation Timeout Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

cnxVldTmoutClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.120
Connection Validation Timeout Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

posRxHighRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.121
Receive power out of spec, High Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

posRxHighClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.122
Receive power out of spec, High Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

posRxLowRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.123
Receive power out of spec, Low Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

posRxLowClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.124
Receive power out of spec, Low Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

oprHighFailRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.125
Optical Power Received High Fail Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

oprHighFailClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.126
Optical Power Received High Fail Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

obrHtRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.127
Optical back reflection high threshold exceeded Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

obrHtClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.128
Optical back reflection high threshold exceeded Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

aprRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.129
Automatic Power Reduction Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

aprClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.130
Automatic Power Reduction Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

modTempHighThRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.131
Transceiver Module Above High Temperature Threshold Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

modTempHighThClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.132
Transceiver Module Above High Temperature Threshold Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

modTempLowThRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.133
Transceiver Module Below Low Temperature Threshold Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

modTempLowThClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.134
Transceiver Module Below Low Temperature Threshold Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

modTempShutdownRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.135
Transceiver Module Temperature Shutdown Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

modTempShutdownClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.136
Transceiver Module Temperature Shutdown Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

envTempHighThRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.137
Environment Above High Temperature Threshold Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

envTempHighThClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.138
Environment Above High Temperature Threshold Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

envTempLowThRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.139
Environment Below Low Temperature Threshold Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

envTempLowThClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.140
Environment Below Low Temperature Threshold Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

envTempFailRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.141
Environment temperature failure Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

envTempFailClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.142
Environment temperature failure Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

envVoltHighThRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.143
Environment Above High Voltage Threshold Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

envVoltHighThClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.144
Environment Above High Voltage Threshold Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

envVoltLowThRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.145
Environment Below Low Voltage Threshold Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

envVoltLowThClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.146
Environment Below Low Voltage Threshold Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

envVoltFailRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.147
Environment voltage failure Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

envVoltFailClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.148
Environment voltage failure Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

scmNmiDownRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.149
SCM Network Management Interface down Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

scmNmiDownClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.150
SCM Network Management Interface down Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

scmNoNmConnRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.151
No Network Management Connectivity on both SCMs Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

scmNoNmConnClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.152
No Network Management Connectivity on both SCMs Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

eqptLatchOpenRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.153
Equipment Latch Open Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

eqptLatchOpenClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.154
Equipment Latch Open Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

powerAbsentRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.155
No Power available Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

powerAbsentClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.156
No Power available Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

fanSpeedLowThRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.157
Fan speed below low threshold Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

fanSpeedLowThClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.158
Fan speed below low threshold Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

nonCoLocatedControllerRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.159
Controllers are in different chassis Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

nonCoLocatedControllerClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.160
Controllers are in different chassis Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

preFecBerThRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.161
Pre-FEC Bit Error Ratio Above High Threshold Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

preFecBerThClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.162
Pre-FEC Bit Error Ratio Above High Threshold Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

firmUpgrdReqdRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.163
Firmware Upgrade Required Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

firmUpgrdReqdClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.164
Firmware Upgrade Required Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

otuBerThRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.165
OTU Bit Error Ratio Above High Threshold Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

otuBerThClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.166
OTU Bit Error Ratio Above High Threshold Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

oduBerThRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.167
ODU Bit Error Ratio Above High Threshold Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

oduBerThClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.168
ODU Bit Error Ratio Above High Threshold Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

pcsBerThRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.169
PCS Bit Error Ratio Above High Threshold Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

pcsBerThClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.170
PCS Bit Error Ratio Above High Threshold Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

berTh-sRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.171
Section Level Bit Error Ratio Above High Threshold Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

berTh-sClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.172
Section Level Bit Error Ratio Above High Threshold Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

berTh-lRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.173
Line Level Bit Error Ratio Above High Threshold Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

berTh-lClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.174
Line Level Bit Error Ratio Above High Threshold Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

rs-berThRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.175
Regenerator Section Bit Error Ratio Above High Threshold Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

rs-berThClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.176
Regenerator Section Bit Error Ratio Above High Threshold Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

ms-berThRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.177
Multiplex Section Bit Error Ratio Above High Threshold Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

ms-berThClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.178
Multiplex Section Bit Error Ratio Above High Threshold Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

oneCableDisconnectedRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.179
One Multichassis Cable Disconnected Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

oneCableDisconnectedClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.180
One Multichassis Cable Disconnected Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

envCurrentHighThRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.181
High Current Threshold Required Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

envCurrentHighThClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.182
High Current Threshold Requires Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

envCurrentLowThRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.183
Low Current Threshold Required Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

envCurrentLowThClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.184
Low Current Threshold Requires Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

prbsRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.185
PRBS test active
Status: current Access: read-write
NOTIFICATION-TYPE    

prbsClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.186
PRBS test active cleared
Status: current Access: read-write
NOTIFICATION-TYPE    

forcedRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.187
Forced protection switch Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

forcedClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.188
Forced protection switch Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

defRDICCMRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.189
Receiving RDI from remote MEP Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

defRDICCMClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.190
Receiving RDI from remote MEP Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

defMACStatusRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.191
Port status failure of remote MEP Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

defMACStatusClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.192
Port status failure of remote MEP Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

defRemoteCCMRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.193
Lost connection with remote MEP Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

defRemoteCCMClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.194
Lost connection with remote MEP Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

defErrorCCMRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.195
Receiving invalid CCM packet from remote MEP Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

defErrorCCMClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.196
Receiving invalid CCM packet from remote MEP Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

defXconCCMRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.197
Receiving cross connect CCMs Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

defXconCCMClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.198
Receiving cross connect CCMs Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

defBfdDownRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.199
BFD session down Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

defBfdDownClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.200
BFD session down Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

isisDbOvrldRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.201
ISIS Database Overloaded Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

isisDbOvrldClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.202
ISIS Database Overloaded Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

isisXDownRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.203
ISIS Circuit Down Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

isisXDownClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.204
ISIS Circuit Down Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

isisAdjDownRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.205
ISIS Adjacency Down Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

isisAdjDownClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.206
ISIS Adjacency Down Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

isisAdjRejectedRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.207
ISIS Adjacency Rejected Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

isisAdjRejectedClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.208
ISIS Adjacency Rejected Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

rsvpAdjDownRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.209
RSVP Adjacency Down Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

rsvpAdjDownClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.210
RSVP Adjacency Down Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

diskHighUsageRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.211
Disk High Usage Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

diskHighUsageClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.212
Disk High Usage Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

memHighUsageRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.213
Memory High Usage Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

memHighUsageClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.214
Memory High Usage Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

lockoutRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.215
Lockout protection switch Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

lockoutClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.216
Lockout protection switch Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

invUnknownRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.217
Inventory Unknown raise
Status: current Access: read-write
NOTIFICATION-TYPE    

invUnknownClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.218
Inventory Unknown clear
Status: current Access: read-write
NOTIFICATION-TYPE    

airfilterAbsenseRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.219
AirFilter Absense Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

airfilterAbsenseClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.220
AirFilter Absense Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

firmUpgrdFailRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.221
Shelf manager firmware upgrade failed Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

firmUpgrdFailClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.222
Shelf manager firmware upgrade failed Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

partitionFaultRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.223
Disk partition fault detected Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

partitionFaultClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.224
Disk partition fault detected Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

lolckRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.225
Loss of Lock Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

lolckClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.226
Loss of Lock Clear
Status: current Access: read-write
NOTIFICATION-TYPE    

inventoryUnsuppRaise 1.3.6.1.4.1.18070.2.9.2.1.2.1.227
Inventory Item Unsupported Raise
Status: current Access: read-write
NOTIFICATION-TYPE    

inventoryUnsuppClear 1.3.6.1.4.1.18070.2.9.2.1.2.1.228
Inventory Item Unsupported Clear
Status: current Access: read-write
NOTIFICATION-TYPE