BRWAVE-RADIO-MIB

File: BRWAVE-RADIO-MIB.mib (14048 bytes)

Imported modules

IF-MIB SNMPv2-CONF SNMPv2-SMI
SNMPv2-TC

Imported symbols

ifIndex OBJECT-GROUP Integer32
MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-IDENTITY
OBJECT-TYPE Unsigned32 enterprises
DisplayString

Defined Values

brwaveRadioMibModule 1.3.6.1.4.1.6080.1.1.3
Radio MIB module.
MODULE-IDENTITY    

bridgeWave 1.3.6.1.4.1.6080
BridgeWave enterprise OID.
Status: current Access: read-write
OBJECT-IDENTITY    

brwaveReg 1.3.6.1.4.1.6080.1
Sub-tree for BridgeWave objects registration.
Status: current Access: read-write
OBJECT-IDENTITY    

brwaveMibs 1.3.6.1.4.1.6080.1.1
Sub-tree to register values assigned to MIB modules with the MODULES-IDENTITY construct.
Status: current Access: read-write
OBJECT-IDENTITY    

brwaveModules 1.3.6.1.4.1.6080.1.2
Sub-tree to register unique values assigned to identify all BridgeWave hardware and software components of ethernet radio products.
Status: current Access: read-write
OBJECT-IDENTITY    

brwaveRadioFE60 1.3.6.1.4.1.6080.1.2.1
Registered System OID for FE60 radio.
Status: current Access: read-write
OBJECT-IDENTITY    

brwaveRadioGE60 1.3.6.1.4.1.6080.1.2.2
Registered System OID for GE60 radio.
Status: current Access: read-write
OBJECT-IDENTITY    

brwaveRadioAR60 1.3.6.1.4.1.6080.1.2.3
Registered system OID for AdaptiveRate(AR60) radio.
Status: current Access: read-write
OBJECT-IDENTITY    

brwaveCommon 1.3.6.1.4.1.6080.2
Sub-tree for BridgeWave objects common across products.
Status: current Access: read-write
OBJECT-IDENTITY    

brwaveRadioSn 1.3.6.1.4.1.6080.2.1
Radio serial number.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

brwaveUnitModel 1.3.6.1.4.1.6080.2.2
Unit's model.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

brwaveBbSn 1.3.6.1.4.1.6080.2.3
Base Band hardware serial number
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

brwaveIfSn 1.3.6.1.4.1.6080.2.4
IF hardware serial number
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

brwaveMmwSn 1.3.6.1.4.1.6080.2.5
MMW Hardware serial number
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

brwaveTrapCount 1.3.6.1.4.1.6080.2.6
Number of traps generated by unit since start-up. Rolls back to zero once reached to maximum value.
Status: current Access: read-only
OBJECT-TYPE    
  Unsigned32  

brwaveProducts 1.3.6.1.4.1.6080.3
Sub-tree for product specific objects & events
Status: current Access: read-only
OBJECT-IDENTITY    

brwaveRadio 1.3.6.1.4.1.6080.3.1
Ethernet Radio (FE60/GE60/AR60) obejcts.
Status: current Access: read-only
OBJECT-IDENTITY    

brwaveRadioFactorySetup 1.3.6.1.4.1.6080.3.1.2
Group of factory setup objects.
Status: current Access: read-only
OBJECT-IDENTITY    

brwaveRadioTxBand 1.3.6.1.4.1.6080.3.1.2.1
Radio Link Transmit frequency.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER low(1), high(2)  

brwaveRadioFactoryRate 1.3.6.1.4.1.6080.3.1.2.3
Factory configured radio link rate.
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER adaptRate(1), mbps1000(2), mbps100(3)  

brwaveRadioClearStats 1.3.6.1.4.1.6080.3.1.2.4
Clear Statistics, Set value of 1 to clear. Returns always 0 when read.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32  

brwaveRadioStatus 1.3.6.1.4.1.6080.3.1.3
Group of radio status objects.
Status: current Access: read-write
OBJECT-IDENTITY    

brwaveRadioInVoltage 1.3.6.1.4.1.6080.3.1.3.1
Input voltage. The reading of the unit's input voltage level in Volts x100.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

brwaveRadioUnitTemperature 1.3.6.1.4.1.6080.3.1.3.2
Unit Temperature. The reading of the temperature sensor in degrees C x 100.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

brwaveRadioTxTemperature 1.3.6.1.4.1.6080.3.1.3.3
Radio Transmiter Temperature. The reading of the radio temperature sensor in degrees C x 100.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

brwaveRadioRSL 1.3.6.1.4.1.6080.3.1.3.4
Received Signal Level. The signal level of the received radio frequency in dBm x 100
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

brwaveRadioRSLVoltage 1.3.6.1.4.1.6080.3.1.3.5
Received Signal Level measured as Voltage.
Status: current Access: read-only
OBJECT-TYPE    
  DisplayString  

brwaveRadioAbsRSL 1.3.6.1.4.1.6080.3.1.3.6
Received Signal Level. The signal level of the received radio frequency in dBm x 100
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

brwaveRadioRSLVoltageInt 1.3.6.1.4.1.6080.3.1.3.7
Received Signal Level measured as Voltage.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

brwaveCopperUtilization 1.3.6.1.4.1.6080.3.1.3.8
Link utilization calculated every polling interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

brwaveFiberUtilization 1.3.6.1.4.1.6080.3.1.3.9
Link utilization calculated every polling interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

brwaveRadioUtilization 1.3.6.1.4.1.6080.3.1.3.10
Link utilization calculated every polling interval.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

brwaveRadioFecError 1.3.6.1.4.1.6080.3.1.3.11
Post and Pre FEC error calculated every polling interval 0 - No Error, 1-Pre FEC Error, 2-Post FEC Error
Status: current Access: read-only
OBJECT-TYPE    
  INTEGER noError(0), preFec(1), postFec(2)  

brwaveRadioPreFecFlag 1.3.6.1.4.1.6080.3.1.3.12
Pre FEC error flag every polling interval
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

brwaveRadioPostFecFlag 1.3.6.1.4.1.6080.3.1.3.13
Post FEC error Flag every polling interval
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

brwaveRadioLinkRate 1.3.6.1.4.1.6080.3.1.3.14
Radio Link Rate in Mbps.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

brwaveRadioEvents 1.3.6.1.4.1.6080.3.1.9
OBJECT IDENTIFIER    

brwaveRadioEventsV2 1.3.6.1.4.1.6080.3.1.9.0
OBJECT IDENTIFIER    

brwaveRadioTrapObjs 1.3.6.1.4.1.6080.3.1.9.1
OBJECT IDENTIFIER    

managerIP 1.3.6.1.4.1.6080.3.1.9.1.1
IP address of NMS station accessing the unit.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  OCTET STRING Size(0..32)  

userName 1.3.6.1.4.1.6080.3.1.9.1.2
User accessing the unit.
Status: current Access: accessible-for-notify
OBJECT-TYPE    
  OCTET STRING Size(0..32)  

brwaveConformance 1.3.6.1.4.1.6080.3.1.10
OBJECT IDENTIFIER    

brwaveRadioGroups 1.3.6.1.4.1.6080.3.1.10.1
OBJECT IDENTIFIER    

brwaveCompliances 1.3.6.1.4.1.6080.3.1.10.2
OBJECT IDENTIFIER    

brwaveErrorsOverThreshold 1.3.6.1.4.1.6080.3.1.9.0.1
Link has error rate over threshold.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

brwaveErrorsUnderThreshold 1.3.6.1.4.1.6080.3.1.9.0.2
Link error rate changed from over to under threshold .
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

brwaveUnitTemperatureAbnormal 1.3.6.1.4.1.6080.3.1.9.0.3
Radio unit temperature not in normal operating range. Normal range is: -20 to +75 degree Centigrade.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

brwaveUnitTemperatureNormal 1.3.6.1.4.1.6080.3.1.9.0.4
Unit temperature restores from abnormal to normal range.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

brwaveTxTemperatureAbnormal 1.3.6.1.4.1.6080.3.1.9.0.5
Transmitter temperature is not in normal operating range. Normal range is: -20 to +75 degree Centigrade.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

brwaveTxTemperatureNormal 1.3.6.1.4.1.6080.3.1.9.0.6
Transmitter temperature is restored to normal range.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

brwaveInputVoltageAbnormal 1.3.6.1.4.1.6080.3.1.9.0.7
Unit's input voltage is not in normal range. Normal input voltage > 16 Volts.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

brwaveInputVoltageNormal 1.3.6.1.4.1.6080.3.1.9.0.8
Unit's input voltage is restored to normal range.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

brwaveRslNormal 1.3.6.1.4.1.6080.3.1.9.0.10
Received Signal Level is normal. Normal signal level RSL > -55.00 dBm (Gigabit) and RSL > -59.00 dBm (Fast Ethernet).
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

brwaveRslMinor 1.3.6.1.4.1.6080.3.1.9.0.11
Received Signal Leve droped to the level of minor event. RSL from -55.00 to -59.00 dBm (GE Radio) RSL from -59.00 to -65.00 dBm (FE radio).
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

brwaveRslMajor 1.3.6.1.4.1.6080.3.1.9.0.13
RSL droppped to the level of major event. RSL < -59.00 dBm (GE Radio) or RSL < -65 dBm (FE radio).
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

brwaveConfigChange 1.3.6.1.4.1.6080.3.1.9.0.26
Configuration changes are performed by WEB client.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

brwaveLoginSuccessfull 1.3.6.1.4.1.6080.3.1.9.0.27
NMS Loged in successfully.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

brwaveGeToFeSwitch 1.3.6.1.4.1.6080.3.1.9.0.28
Tx Rate switched from GE to FE.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

brwaveFeToGeSwitch 1.3.6.1.4.1.6080.3.1.9.0.29
Tx Rate switched from FE to GE.
Status: current Access: accessible-for-notify
NOTIFICATION-TYPE    

brwaveCommonGroup 1.3.6.1.4.1.6080.3.1.10.1.1
Collection of common objects.
Status: current Access: accessible-for-notify
OBJECT-GROUP    

brwaveFactoryGroup 1.3.6.1.4.1.6080.3.1.10.1.2
Collection of factory setup objects.
Status: current Access: accessible-for-notify
OBJECT-GROUP    

brwaveStatusGroup 1.3.6.1.4.1.6080.3.1.10.1.3
Collection of status objects.
Status: current Access: accessible-for-notify
OBJECT-GROUP