BRWAVE-RADIO-MIB
File:
BRWAVE-RADIO-MIB.mib (14048 bytes)
Imported modules
Imported symbols
Defined Values
bridgeWave |
1.3.6.1.4.1.6080 |
BridgeWave enterprise OID. |
Status: current |
Access: read-write |
OBJECT-IDENTITY |
|
|
|
brwaveReg |
1.3.6.1.4.1.6080.1 |
Sub-tree for BridgeWave objects registration. |
Status: current |
Access: read-write |
OBJECT-IDENTITY |
|
|
|
brwaveMibs |
1.3.6.1.4.1.6080.1.1 |
Sub-tree to register values assigned to MIB modules
with the MODULES-IDENTITY construct. |
Status: current |
Access: read-write |
OBJECT-IDENTITY |
|
|
|
brwaveModules |
1.3.6.1.4.1.6080.1.2 |
Sub-tree to register unique values assigned to
identify all BridgeWave hardware and software
components of ethernet radio products. |
Status: current |
Access: read-write |
OBJECT-IDENTITY |
|
|
|
brwaveRadioFE60 |
1.3.6.1.4.1.6080.1.2.1 |
Registered System OID for FE60 radio. |
Status: current |
Access: read-write |
OBJECT-IDENTITY |
|
|
|
brwaveRadioGE60 |
1.3.6.1.4.1.6080.1.2.2 |
Registered System OID for GE60 radio. |
Status: current |
Access: read-write |
OBJECT-IDENTITY |
|
|
|
brwaveRadioAR60 |
1.3.6.1.4.1.6080.1.2.3 |
Registered system OID for AdaptiveRate(AR60) radio. |
Status: current |
Access: read-write |
OBJECT-IDENTITY |
|
|
|
brwaveCommon |
1.3.6.1.4.1.6080.2 |
Sub-tree for BridgeWave objects common across products. |
Status: current |
Access: read-write |
OBJECT-IDENTITY |
|
|
|
brwaveBbSn |
1.3.6.1.4.1.6080.2.3 |
Base Band hardware serial number |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
brwaveIfSn |
1.3.6.1.4.1.6080.2.4 |
IF hardware serial number |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
|
|
brwaveTrapCount |
1.3.6.1.4.1.6080.2.6 |
Number of traps generated by unit since start-up.
Rolls back to zero once reached to maximum value. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Unsigned32 |
|
|
brwaveProducts |
1.3.6.1.4.1.6080.3 |
Sub-tree for product specific objects & events |
Status: current |
Access: read-only |
OBJECT-IDENTITY |
|
|
|
brwaveRadio |
1.3.6.1.4.1.6080.3.1 |
Ethernet Radio (FE60/GE60/AR60) obejcts. |
Status: current |
Access: read-only |
OBJECT-IDENTITY |
|
|
|
brwaveRadioFactorySetup |
1.3.6.1.4.1.6080.3.1.2 |
Group of factory setup objects. |
Status: current |
Access: read-only |
OBJECT-IDENTITY |
|
|
|
brwaveRadioTxBand |
1.3.6.1.4.1.6080.3.1.2.1 |
Radio Link Transmit frequency. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
low(1), high(2) |
|
brwaveRadioFactoryRate |
1.3.6.1.4.1.6080.3.1.2.3 |
Factory configured radio link rate. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
adaptRate(1), mbps1000(2), mbps100(3) |
|
brwaveRadioClearStats |
1.3.6.1.4.1.6080.3.1.2.4 |
Clear Statistics, Set value of 1 to clear.
Returns always 0 when read. |
Status: current |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
brwaveRadioStatus |
1.3.6.1.4.1.6080.3.1.3 |
Group of radio status objects. |
Status: current |
Access: read-write |
OBJECT-IDENTITY |
|
|
|
brwaveRadioInVoltage |
1.3.6.1.4.1.6080.3.1.3.1 |
Input voltage. The reading of the unit's input voltage
level in Volts x100. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
brwaveRadioUnitTemperature |
1.3.6.1.4.1.6080.3.1.3.2 |
Unit Temperature. The reading of the temperature sensor
in degrees C x 100. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
brwaveRadioTxTemperature |
1.3.6.1.4.1.6080.3.1.3.3 |
Radio Transmiter Temperature. The reading of the radio
temperature sensor in degrees C x 100. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
brwaveRadioRSL |
1.3.6.1.4.1.6080.3.1.3.4 |
Received Signal Level. The signal level of the received
radio frequency in dBm x 100 |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
brwaveRadioAbsRSL |
1.3.6.1.4.1.6080.3.1.3.6 |
Received Signal Level. The signal level of the received
radio frequency in dBm x 100 |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
brwaveFiberUtilization |
1.3.6.1.4.1.6080.3.1.3.9 |
Link utilization calculated every polling interval. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
brwaveRadioUtilization |
1.3.6.1.4.1.6080.3.1.3.10 |
Link utilization calculated every polling interval. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
brwaveRadioFecError |
1.3.6.1.4.1.6080.3.1.3.11 |
Post and Pre FEC error calculated every polling interval
0 - No Error, 1-Pre FEC Error, 2-Post FEC Error |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
noError(0), preFec(1), postFec(2) |
|
brwaveRadioPostFecFlag |
1.3.6.1.4.1.6080.3.1.3.13 |
Post FEC error Flag every polling interval |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
managerIP |
1.3.6.1.4.1.6080.3.1.9.1.1 |
IP address of NMS station accessing the unit. |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(0..32) |
|
userName |
1.3.6.1.4.1.6080.3.1.9.1.2 |
User accessing the unit. |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
Size(0..32) |
|
brwaveErrorsOverThreshold |
1.3.6.1.4.1.6080.3.1.9.0.1 |
Link has error rate over threshold. |
Status: current |
Access: accessible-for-notify |
NOTIFICATION-TYPE |
|
|
|
brwaveErrorsUnderThreshold |
1.3.6.1.4.1.6080.3.1.9.0.2 |
Link error rate changed from over to under threshold . |
Status: current |
Access: accessible-for-notify |
NOTIFICATION-TYPE |
|
|
|
brwaveUnitTemperatureAbnormal |
1.3.6.1.4.1.6080.3.1.9.0.3 |
Radio unit temperature not in normal operating range.
Normal range is: -20 to +75 degree Centigrade. |
Status: current |
Access: accessible-for-notify |
NOTIFICATION-TYPE |
|
|
|
brwaveUnitTemperatureNormal |
1.3.6.1.4.1.6080.3.1.9.0.4 |
Unit temperature restores from abnormal to normal range. |
Status: current |
Access: accessible-for-notify |
NOTIFICATION-TYPE |
|
|
|
brwaveTxTemperatureAbnormal |
1.3.6.1.4.1.6080.3.1.9.0.5 |
Transmitter temperature is not in normal operating range.
Normal range is: -20 to +75 degree Centigrade. |
Status: current |
Access: accessible-for-notify |
NOTIFICATION-TYPE |
|
|
|
brwaveTxTemperatureNormal |
1.3.6.1.4.1.6080.3.1.9.0.6 |
Transmitter temperature is restored to normal range. |
Status: current |
Access: accessible-for-notify |
NOTIFICATION-TYPE |
|
|
|
brwaveRslNormal |
1.3.6.1.4.1.6080.3.1.9.0.10 |
Received Signal Level is normal. Normal signal level
RSL > -55.00 dBm (Gigabit) and RSL > -59.00 dBm (Fast Ethernet). |
Status: current |
Access: accessible-for-notify |
NOTIFICATION-TYPE |
|
|
|
brwaveRslMinor |
1.3.6.1.4.1.6080.3.1.9.0.11 |
Received Signal Leve droped to the level of minor event.
RSL from -55.00 to -59.00 dBm (GE Radio)
RSL from -59.00 to -65.00 dBm (FE radio). |
Status: current |
Access: accessible-for-notify |
NOTIFICATION-TYPE |
|
|
|
brwaveRslMajor |
1.3.6.1.4.1.6080.3.1.9.0.13 |
RSL droppped to the level of major event.
RSL < -59.00 dBm (GE Radio) or RSL < -65 dBm (FE radio). |
Status: current |
Access: accessible-for-notify |
NOTIFICATION-TYPE |
|
|
|
brwaveConfigChange |
1.3.6.1.4.1.6080.3.1.9.0.26 |
Configuration changes are performed by WEB client. |
Status: current |
Access: accessible-for-notify |
NOTIFICATION-TYPE |
|
|
|
brwaveLoginSuccessfull |
1.3.6.1.4.1.6080.3.1.9.0.27 |
NMS Loged in successfully. |
Status: current |
Access: accessible-for-notify |
NOTIFICATION-TYPE |
|
|
|
brwaveGeToFeSwitch |
1.3.6.1.4.1.6080.3.1.9.0.28 |
Tx Rate switched from GE to FE. |
Status: current |
Access: accessible-for-notify |
NOTIFICATION-TYPE |
|
|
|
brwaveFeToGeSwitch |
1.3.6.1.4.1.6080.3.1.9.0.29 |
Tx Rate switched from FE to GE. |
Status: current |
Access: accessible-for-notify |
NOTIFICATION-TYPE |
|
|
|
brwaveCommonGroup |
1.3.6.1.4.1.6080.3.1.10.1.1 |
Collection of common objects. |
Status: current |
Access: accessible-for-notify |
OBJECT-GROUP |
|
|
|
brwaveFactoryGroup |
1.3.6.1.4.1.6080.3.1.10.1.2 |
Collection of factory setup objects. |
Status: current |
Access: accessible-for-notify |
OBJECT-GROUP |
|
|
|
brwaveStatusGroup |
1.3.6.1.4.1.6080.3.1.10.1.3 |
Collection of status objects. |
Status: current |
Access: accessible-for-notify |
OBJECT-GROUP |
|
|
|