BIANCA-BRICK-POTS-MIB

File: BIANCA-BRICK-POTS-MIB.mib (2339 bytes)

Imported modules

RFC1155-SMI RFC-1212

Imported symbols

Counter OBJECT-TYPE

Defined Types

PotsIfEntry  
SEQUENCE    
  potsSlot INTEGER
  potsUnit INTEGER
  potsType INTEGER
  potsCallWaiting INTEGER
  potsFaxDetection INTEGER

Defined Values

org 1.3
OBJECT IDENTIFIER    

dod 1.3.6
OBJECT IDENTIFIER    

internet 1.3.6.1
OBJECT IDENTIFIER    

private 1.3.6.1.4
OBJECT IDENTIFIER    

enterprises 1.3.6.1.4.1
OBJECT IDENTIFIER    

bintec 1.3.6.1.4.1.272
OBJECT IDENTIFIER    

bibo 1.3.6.1.4.1.272.4
OBJECT IDENTIFIER    

pots 1.3.6.1.4.1.272.4.14
OBJECT IDENTIFIER    

potsIfTable 1.3.6.1.4.1.272.4.14.1
The potsIfTable contains configuration information for the POTS outlets.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    PotsIfEntry

potsIfEntry 1.3.6.1.4.1.272.4.14.1.1
Tok_String
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  PotsIfEntry  

potsSlot 1.3.6.1.4.1.272.4.14.1.1.1
Identification number of the used slot.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..31  

potsUnit 1.3.6.1.4.1.272.4.14.1.1.2
Identification number of the used unit.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER 0..31  

potsType 1.3.6.1.4.1.272.4.14.1.1.3
The type of the connected device on socket a.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER any(1), fax(2), telephony(3), modem(4), disable(5)