BAS-SONET-MIB

File: BAS-SONET-MIB.mib (11338 bytes)

Imported modules

SNMPv2-SMI IF-MIB SNMPv2-TC
SNMPv2-CONF BAS-MIB

Imported symbols

MODULE-IDENTITY OBJECT-TYPE Counter32
Integer32 ifIndex TimeStamp
TEXTUAL-CONVENTION OBJECT-GROUP MODULE-COMPLIANCE
basSonet

Defined Types

BasSonetPathEntry  
SEQUENCE    
  basSonetPathB3Err Counter32
  basSonetPathG1Err Counter32
  basSonetPathPais Counter32
  basSonetPathPrdi Counter32
  basSonetPathPlop Counter32
  basSonetPathB3Threshold Integer32
  basSonetPathRxJ1 Integer32
  basSonetPathRxC2 Integer32
  basSonetPathRxG1 Integer32

BasSonetLineEntry  
SEQUENCE    
  basSonetLineTxErr Counter32
  basSonetLineB1Err Counter32
  basSonetLineB2Err Counter32
  basSonetLineM1Err Counter32
  basSonetLineRxFifoOverflow Counter32
  basSonetLineRxAbort Counter32
  basSonetLineRxRunts Counter32
  basSonetLineLoc Counter32
  basSonetLineLof Counter32
  basSonetLineLos Counter32
  basSonetLineLais Counter32
  basSonetLineLrdi Counter32
  basSonetLineB1Threshold Integer32
  basSonetLineB2Threshold Integer32
  basSonetLineSFThreshold Integer32
  basSonetLineSDThreshold Integer32
  basSonetLineLastCleared TimeStamp
  basSonetLineRxK1 Integer32
  basSonetLineRxK2 Integer32
  basSonetLineRxGiants Counter32

Defined Values

basSonetMib 1.3.6.1.4.1.3493.2.20.1
This MIB module defines the configuration and status MIB objects for a Broadband Access System SONET interface.
MODULE-IDENTITY    

basSonetObjects 1.3.6.1.4.1.3493.2.20.1.1
OBJECT IDENTIFIER    

basSonetPathTable 1.3.6.1.4.1.3493.2.20.1.1.1
A table containing SONET Path specific variables for this POS implementation.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    BasSonetPathEntry

basSonetPathEntry 1.3.6.1.4.1.3493.2.20.1.1.1.1
Management information about a particular POS Link.
Status: current Access: not-accessible
OBJECT-TYPE    
  BasSonetPathEntry  

basSonetPathB3Err 1.3.6.1.4.1.3493.2.20.1.1.1.1.1
The number of packets received on this link with B3 bit errors. Bit Interleaved Parity 8 is calculated over all bits in the SPE of each frame.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

basSonetPathG1Err 1.3.6.1.4.1.3493.2.20.1.1.1.1.2
The number of B3 errors that were detected by the remote terminal in its received signal.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

basSonetPathPais 1.3.6.1.4.1.3493.2.20.1.1.1.1.3
The number of times a Path Alarm Indication Signal has been detected. A PAIS occurs if all the H1/H2 pointer bytes in the received SONET frame are 01.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

basSonetPathPrdi 1.3.6.1.4.1.3493.2.20.1.1.1.1.4
The number of times a Path Remote Defect Indication has been detected. A PRDI occurs if bits 5,6 and 7 of the G1 byte received with the same value for 5 onsecutive frames.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

basSonetPathPlop 1.3.6.1.4.1.3493.2.20.1.1.1.1.5
The number of times a Path Loss of Pointer has been detected. A PLOP occurs if all the H1/H2 pointer bytes in the received SONET frame are not all 01 indicating PRDI or the first pair equals 00 and all other pairs equaling 11 indicating normal operation.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

basSonetPathB3Threshold 1.3.6.1.4.1.3493.2.20.1.1.1.1.6
The number of packets received with B3 errors hits this threshold issue an alarm.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 3..9  

basSonetPathRxJ1 1.3.6.1.4.1.3493.2.20.1.1.1.1.7
The first J1 byte received in last packet.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

basSonetPathRxC2 1.3.6.1.4.1.3493.2.20.1.1.1.1.8
C2 byte received in last packet.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

basSonetPathRxG1 1.3.6.1.4.1.3493.2.20.1.1.1.1.9
G1 byte received in last packet.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

basSonetLineTable 1.3.6.1.4.1.3493.2.20.1.1.2
A table containing SONET Line specific variables for this POS implementation.
Status: current Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    BasSonetLineEntry

basSonetLineEntry 1.3.6.1.4.1.3493.2.20.1.1.2.1
Management information about a particular POS Link.
Status: current Access: not-accessible
OBJECT-TYPE    
  BasSonetLineEntry  

basSonetLineTxErr 1.3.6.1.4.1.3493.2.20.1.1.2.1.1
The sum of all transmit errors that caused the packet to not be transmitted. These errors consist of tx fifo error, link layer errors, minimum packet size violations, maximum packet size violations and tx parity errors.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

basSonetLineB1Err 1.3.6.1.4.1.3493.2.20.1.1.2.1.2
The number of packets received on this link with B1 bit errors. Bit Interleaved Parity 8 is calculated over all bytes of each frame.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

basSonetLineB2Err 1.3.6.1.4.1.3493.2.20.1.1.2.1.3
The number of packets received on this link with B2 bit errors. Bit Interleaved Parity 8 is calculated over all bytes of each frame except for the first three rows of the TOH
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

basSonetLineM1Err 1.3.6.1.4.1.3493.2.20.1.1.2.1.4
The number of B2 errors that were detected by the remote terminal in its received signal.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

basSonetLineRxFifoOverflow 1.3.6.1.4.1.3493.2.20.1.1.2.1.5
The number of packets received on this link with an error detected in the receive fifo.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

basSonetLineRxAbort 1.3.6.1.4.1.3493.2.20.1.1.2.1.6
The number of packets received on this link in which the abort sequence is detected.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

basSonetLineRxRunts 1.3.6.1.4.1.3493.2.20.1.1.2.1.7
The number of packets received on this link which are smaller than the minimum packet size.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

basSonetLineLoc 1.3.6.1.4.1.3493.2.20.1.1.2.1.8
The number of times a loss of clock has been detected. LOC occurs if no transitions are detected on the receive SONET clock for 16 periods of the transmit clock..
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

basSonetLineLof 1.3.6.1.4.1.3493.2.20.1.1.2.1.9
The number of times a loss of frame has been detected. LOF occurs if RX_OOF (out-of-frame) is active continuously for 24 consecutive frames (3 ms).
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

basSonetLineLos 1.3.6.1.4.1.3493.2.20.1.1.2.1.10
The number of times a loss of signal has been detected. A LOS indicates to the framer that there is no signal present from the optical receiver.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

basSonetLineLais 1.3.6.1.4.1.3493.2.20.1.1.2.1.11
The number of times a Line Alarm Indication Signal has been detected. A LAIS occurs if the 3 LSBs of K2 are received as '111' for 5 consecutive frames
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

basSonetLineLrdi 1.3.6.1.4.1.3493.2.20.1.1.2.1.12
The number of times a Line Remote Defect Indication has been detected. A LRDI occurs if the 3 LSBs of K2 are not received as '110' for 5 consecutive frames.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32  

basSonetLineB1Threshold 1.3.6.1.4.1.3493.2.20.1.1.2.1.13
The number of packets received with B1 errors hits this threshold issue an alarm.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 3..9  

basSonetLineB2Threshold 1.3.6.1.4.1.3493.2.20.1.1.2.1.14
The number of packets received with B2 errors hits this threshold issue an alarm.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 3..9  

basSonetLineSFThreshold 1.3.6.1.4.1.3493.2.20.1.1.2.1.15
The number of packets received with B2 errors hits this threshold issue a signal fail alarm.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 3..9  

basSonetLineSDThreshold 1.3.6.1.4.1.3493.2.20.1.1.2.1.16
The number of packets received with B2 errors hits this threshold issue a signal degrade alarm.
Status: current Access: read-write
OBJECT-TYPE    
  Integer32 3..9  

basSonetLineLastCleared 1.3.6.1.4.1.3493.2.20.1.1.2.1.17
The value of sysUpTime when these Counter32s were last cleared.
Status: current Access: read-only
OBJECT-TYPE    
  TimeStamp  

basSonetLineRxK1 1.3.6.1.4.1.3493.2.20.1.1.2.1.18
K1 byte received in last packet.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

basSonetLineRxK2 1.3.6.1.4.1.3493.2.20.1.1.2.1.19
K2 byte received in last packet.
Status: current Access: read-only
OBJECT-TYPE    
  Integer32  

basSonetLineRxGiants 1.3.6.1.4.1.3493.2.20.1.1.2.1.20
The number of packets received on this link which are larger than the maximum packet size.
Status: current Access: read-only
OBJECT-TYPE    
  Counter32