AVAYA-ENTITY-MIB
File:
AVAYA-ENTITY-MIB.mib (30018 bytes)
Imported modules
Imported symbols
Defined Types
AvEntPhyItuPerceivedSeverity |
|
ITU perceived severity values |
TEXTUAL-CONVENTION |
|
|
|
|
INTEGER |
cleared(1), indeterminate(2), critical(3), major(4), minor(5), warning(6) |
|
AvEntPhySensorEntry |
|
SEQUENCE |
|
|
|
|
avEntPhySensorHiShutdown |
EntitySensorValue |
|
|
avEntPhySensorHiWarning |
EntitySensorValue |
|
|
avEntPhySensorHiWarningClear |
EntitySensorValue |
|
|
avEntPhySensorLoWarningClear |
EntitySensorValue |
|
|
avEntPhySensorLoWarning |
EntitySensorValue |
|
|
avEntPhySensorLoShutdown |
EntitySensorValue |
|
|
avEntPhySensorEventSupportMask |
OCTET STRING |
|
AvEntPhyUSBDevicesEntry |
|
SEQUENCE |
|
|
|
|
avEntPhyUSBDeviceUSBSupportVersion |
DisplayString |
|
|
avEntPhyUSBDeviceClassCode |
Integer32 |
|
|
avEntPhyUSBDeviceSubClassCode |
Integer32 |
|
|
avEntPhyUSBDeviceProtocol |
Integer32 |
|
|
avEntPhyUSBDeviceVendorId |
OCTET STRING |
|
|
avEntPhyUSBDeviceSpeed |
DisplayString |
|
|
avEntPhyUSBDevicePower |
DisplayString |
|
|
avEntPhyUSBDeviceCurrent |
Integer32 |
|
AvEntPhyUSBMassStorageDevicesEntry |
|
SEQUENCE |
|
|
|
|
avEntPhyUSBMassStorageDeviceFileSystemName |
DisplayString |
|
|
avEntPhyUSBMassStorageDeviceCapacity |
Integer32 |
|
|
avEntPhyUSBMassStorageDeviceFreeMemory |
Integer32 |
|
|
avEntPhyUSBMassStorageDeviceFs |
DisplayString |
|
AvEntPhyChFruEntry |
|
SEQUENCE |
|
|
|
|
avEntPhyChFruOperStat |
INTEGER |
|
|
avEntPhyChFruFault |
INTEGER |
|
Defined Values
avayaEntity |
1.3.6.1.4.1.6889.2.1.99 |
This module defines private extensions for Entity MIB |
MODULE-IDENTITY |
|
|
|
avEntPhySensorTable |
1.3.6.1.4.1.6889.2.1.99.1 |
This table extends entPhySensorTable with thresholds on the sensors. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
AvEntPhySensorEntry |
|
avEntPhySensorEntry |
1.3.6.1.4.1.6889.2.1.99.1.1 |
Thresholds for sensors described in entPhySensorTable.
The Threshold values correspond to entPhySensorValue.
Entries are created in this table by the agent. An entry
for each physical sensor SHOULD be created at the same time
as the associated entPhysicalEntry. An entry SHOULD be
destroyed if the associated entPhysicalEntry is destroyed.
No entry means that no thresholds are defined for the corresponding
sensor |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
AvEntPhySensorEntry |
|
|
avEntPhySensorHiWarning |
1.3.6.1.4.1.6889.2.1.99.1.1.2 |
The system generates a warning event when the sensor reading
rises and crosses this value |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
EntitySensorValue |
|
|
avEntPhySensorLoWarning |
1.3.6.1.4.1.6889.2.1.99.1.1.5 |
The system generates a warning event when the sensor reading
falls and crosses this value |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
EntitySensorValue |
|
|
avEntPhySensorEventSupportMask |
1.3.6.1.4.1.6889.2.1.99.1.1.7 |
A trap and an event is generated upon threshold crossing if the
correspond bit is set. Note that there may be other trap
filtering mechanisms.
0/0: hiShutdown(0)
0/1: hiWarning(1)
0/2: hiWarningClear(2)
0/3: loWarningClear(3)
0/4: loWarning(4)
0/5: loShowdown(5) |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
avEntTraps |
1.3.6.1.4.1.6889.2.1.99.2 |
OBJECT IDENTIFIER |
|
|
|
avEntFanFlt |
1.3.6.1.4.1.6889.2.1.99.2.0.1 |
Fan Fault |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
avEntFanOk |
1.3.6.1.4.1.6889.2.1.99.2.0.2 |
Fan Fault |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
avEnt48vPwrFlt |
1.3.6.1.4.1.6889.2.1.99.2.0.4 |
48V power supply fault |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
avEnt48vPwrFltOk |
1.3.6.1.4.1.6889.2.1.99.2.0.5 |
48V power supply fault clear |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
avEnt5vPwrFlt |
1.3.6.1.4.1.6889.2.1.99.2.0.7 |
5V power supply fault |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
avEnt5vPwrFltOk |
1.3.6.1.4.1.6889.2.1.99.2.0.8 |
5V power supply fault clear |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
avEnt3300mvPwrFlt |
1.3.6.1.4.1.6889.2.1.99.2.0.10 |
3.3V (3300mv) power supply fault |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
avEnt3300mvPwrFltOk |
1.3.6.1.4.1.6889.2.1.99.2.0.11 |
3.3V (3300mv) power supply fault clear |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
avEnt2500mvPwrFlt |
1.3.6.1.4.1.6889.2.1.99.2.0.13 |
2.5V (2500mv) power supply fault |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
avEnt2500mvPwrFltOk |
1.3.6.1.4.1.6889.2.1.99.2.0.14 |
2.5V (2500mv) power supply fault clear |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
avEnt1800mvPwrFlt |
1.3.6.1.4.1.6889.2.1.99.2.0.16 |
1.8V (1800mv) power supply fault |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
avEnt1800mvPwrFltOk |
1.3.6.1.4.1.6889.2.1.99.2.0.17 |
1.8V (1800mv) power supply fault clear |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
avEnt1600mvPwrFlt |
1.3.6.1.4.1.6889.2.1.99.2.0.19 |
1.6V (1600mv) power supply fault |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
avEnt1600mvPwrFltOk |
1.3.6.1.4.1.6889.2.1.99.2.0.20 |
1.6V (1600mv) power supply fault clear |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
avEntAmbientHiTempFlt |
1.3.6.1.4.1.6889.2.1.99.2.0.22 |
Ambient High Temprature fault |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
avEntAmbientHiTempFltOk |
1.3.6.1.4.1.6889.2.1.99.2.0.23 |
Ambient High Temprature clear |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
avEntAmbientLoTempFlt |
1.3.6.1.4.1.6889.2.1.99.2.0.24 |
Ambient Low Temprature fault |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
avEntAmbientLoTempFltOk |
1.3.6.1.4.1.6889.2.1.99.2.0.25 |
Ambient High Temprature clear |
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
avEntPhyUSBDeviceRemovalOnBackupRestoreOperation |
1.3.6.1.4.1.6889.2.1.99.3.0.1 |
The notification is based on usb mass storage device removal during
backup/restore operation to it. If other usb devices are removed during
this operation then no harm/syslog.
|
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
avEntPhyUSBDeviceInsecureRemoval |
1.3.6.1.4.1.6889.2.1.99.3.0.2 |
The notification is based on usb device insecurely removal.
|
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
avEntPhyUSBDevicePowerFailure |
1.3.6.1.4.1.6889.2.1.99.3.0.3 |
The notification is based on usb device lack of power.
For cases as:
a. Connecting device which requires more power then gateway can supply.
b. Connecting USB device to non power hub which has not enough power.
C. Disconnecting power from the USB HUB and there is not enough power to drive
the usb devices.
D. Disconnecting power from a usb device which requires external power.
E. Disconnecting power from USB device and the gateway/USB Hub can not supply
power to it.
|
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
avEntPhyUSBDeviceNotSupported |
1.3.6.1.4.1.6889.2.1.99.3.0.4 |
The notification is based on attaching non supported usb device to the gateway.
The Gateways supports usb mass storage devices based on flash drives that their sub
class is SCSI and their protocol is Bulk Only Transport.
The Gateways supports usb modems that complies to sub class SFF-8020i, MMC-2 (ATAPI)
and protocol Control/Bulk/Interrupt protocol (with no command completion Interrupt).
|
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
avEntPhyUSBDeviceExceedMaxNumber |
1.3.6.1.4.1.6889.2.1.99.3.0.5 |
The notification is based on reaching the max number of usb devices
connected to the gateway.
G250/G350 allows only USB Modem with only one usb mass storage device at the same time.
|
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
avEntPhyUSBFileSystemNotSupported |
1.3.6.1.4.1.6889.2.1.99.3.0.6 |
The notification is based on reaching connecting USB mass storage device with file
system that is not supported.
|
Status: current |
Access: read-only |
NOTIFICATION-TYPE |
|
|
|
avEntPhyUSBDevicesEntry |
1.3.6.1.4.1.6889.2.1.99.3.1.1 |
This table includes extension to entPhysicalTable with usb devices
parameters. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
AvEntPhyUSBDevicesEntry |
|
|
avEntPhyUSBDeviceClassCode |
1.3.6.1.4.1.6889.2.1.99.3.1.1.2 |
The usb device class code.
Value Hex Value Descriptor
1 1 Audio
2 2 CDC-Control
3 3 HID
5 5 Physical
6 6 Image (subclass & protocol must be 1)
7 7 Printer
8 8 Mass-Storage
9 9 HUB
10 A CDC-Data
11 B Chip/Smart Card
13 D Content-Security
14 E Video
220 DC Diagnostic Device (see below for details)
224 E0 Wireless Controller (see below for details)
254 FE Application-Specific (see below for details)
255 FF Vendor-Specific
The G250/G350 supports usb mass storage devices of class code of 0x8
and usb modem with class 0x2.
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
avEntPhyUSBDeviceSubClassCode |
1.3.6.1.4.1.6889.2.1.99.3.1.1.3 |
The usb device subclass code.
USB standard describe the following class codes:
0x01 - RBC (Reduced Block Commands)
0x02 - SFF-8020i, MMC-2 (ATAPI)
0x03 - QIC-157
0x04 - UFI
0x05 - SFF-8070i
0x06 - SCSI
The G250/G350 supports 0x06 - SCSI for USB mass storage devices and
0x2 - SFF-8020i, MMC-2 (ATAPI) for USB modem.
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
avEntPhyUSBDeviceProtocol |
1.3.6.1.4.1.6889.2.1.99.3.1.1.4 |
The usb device protocol code.
0x0 - Control/Bulk/Interrupt protocol (with command completion
Interrupt).
0x1 - Control/Bulk/Interrupt protocol (with no command completion
Interrupt).
0x50 - Bulk Only Transport.
The G250/G350 supports 0x50 protocol for usb mass storage devices and
0x1 for USB modem.
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
avEntPhyUSBDeviceVendorId |
1.3.6.1.4.1.6889.2.1.99.3.1.1.5 |
The USB device vendor HEX-formatted string as it is provided to
the USB host by the USB device |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
OCTET STRING |
|
|
avEntPhyUSBDeviceSpeed |
1.3.6.1.4.1.6889.2.1.99.3.1.1.6 |
The USB device speed.
Possible values: 'Low', 'Full' and 'High'.
G250/G350 supports 'Full' and 'High' |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..64) |
|
avEntPhyUSBDevicePower |
1.3.6.1.4.1.6889.2.1.99.3.1.1.7 |
The USB device power.
Possible values: 'Unknown', 'Self Powered' and 'Bus Powered'.
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..64) |
|
avEntPhyUSBMassStorageDevicesEntry |
1.3.6.1.4.1.6889.2.1.99.3.2.1 |
This table includes extension to entPhysicalTable with usb mass storage
devices parameters. |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
AvEntPhyUSBMassStorageDevicesEntry |
|
|
avEntPhyUSBMassStorageDeviceFileSystemName |
1.3.6.1.4.1.6889.2.1.99.3.2.1.1 |
The usb mass storage device File system name.
An exmaple for one usb mass storage device on the gateway is
mapped to /usbdevice0/.
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..64) |
|
avEntPhyUSBMassStorageDeviceFreeMemory |
1.3.6.1.4.1.6889.2.1.99.3.2.1.3 |
Free memory of USB Mass storage device in KB.
For R/O USB mass storage devices (as CDROM) this value returns 0.
Note that this MIB item shall be updated according backup
operations that may consume memory space.
|
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
Integer32 |
|
|
avEntPhyUSBMassStorageDeviceFs |
1.3.6.1.4.1.6889.2.1.99.3.2.1.4 |
The file system supported by the USB device.
Possible values: 'FAT16' and 'FAT32'. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..64) |
|
avEntPhyProductId |
1.3.6.1.4.1.6889.2.1.99.4.2 |
The Product Id of Avaya Device - 10 characters. |
Status: current |
Access: accessible-for-notify |
OBJECT-TYPE |
|
|
|
|
DisplayString |
Size(0..10) |
|
avEntPhyChFruRemoval |
1.3.6.1.4.1.6889.2.1.99.5.0.1 |
FRU unit was removed from chassis |
Status: current |
Access: accessible-for-notify |
NOTIFICATION-TYPE |
|
|
|
avEntPhyChFruInsertion |
1.3.6.1.4.1.6889.2.1.99.5.0.2 |
FRU unit was inserted into chassis |
Status: current |
Access: accessible-for-notify |
NOTIFICATION-TYPE |
|
|
|
avEntPhyChFruPsuFlt |
1.3.6.1.4.1.6889.2.1.99.5.0.3 |
Power Supply unit failed |
Status: current |
Access: accessible-for-notify |
NOTIFICATION-TYPE |
|
|
|
avEntPhyChFruPsuFltOk |
1.3.6.1.4.1.6889.2.1.99.5.0.4 |
Power Supply unit resumed operation |
Status: current |
Access: accessible-for-notify |
NOTIFICATION-TYPE |
|
|
|
avEntPhyChFruExpansionTestFailure |
1.3.6.1.4.1.6889.2.1.99.5.0.5 |
Cable Test Failure on Expansion module |
Status: current |
Access: accessible-for-notify |
NOTIFICATION-TYPE |
|
|
|
avEntPhyChFruExpansionTestClear |
1.3.6.1.4.1.6889.2.1.99.5.0.6 |
Cable Test Passed OK on Expansion module |
Status: current |
Access: accessible-for-notify |
NOTIFICATION-TYPE |
|
|
|
avEntPhyChFruTable |
1.3.6.1.4.1.6889.2.1.99.5.1 |
Table depicting the status of chassis FRU units such as Power-Supplies and Fan-Tray |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
SEQUENCE OF |
|
|
|
|
AvEntPhyChFruEntry |
|
avEntPhyChFruEntry |
1.3.6.1.4.1.6889.2.1.99.5.1.1 |
Table entry depicting the status of chassis FRU units such as Power-Supplies and Fan-Tray |
Status: current |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
AvEntPhyChFruEntry |
|
|
avEntPhyChFruOperStat |
1.3.6.1.4.1.6889.2.1.99.5.1.1.1 |
Operational status of the chassis FRU unit. |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
ok(1), fault(2), notPresent(3), unknown(255) |
|
avEntPhyChFruFault |
1.3.6.1.4.1.6889.2.1.99.5.1.1.2 |
Description of fault, in case an FRU has failed |
Status: current |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
none(1), mulfunction(2), acFault(3), malfunctionAndAcFault(4), singleFanFault(5), multipleFanFault(6), badExpansionCable(7), unknown(255) |
|
avEntPhyChFruGroup |
1.3.6.1.4.1.6889.2.1.99.5.2 |
avEntPhyChFruGroup |
Status: current |
Access: read-only |
OBJECT-GROUP |
|
|
|