ATT-CNM-DS1-MIB

File: ATT-CNM-DS1-MIB.mib (12768 bytes)

Imported modules

RFC1155-SMI RFC1213-MIB RFC-1212

Imported symbols

enterprises Gauge DisplayString
OBJECT-TYPE

Defined Types

AttCNMds1ConfigEntry  
SEQUENCE    
  attCNMds1ConfigIndex INTEGER
  attCNMds1LineType INTEGER
  attCNMds1ZeroCoding INTEGER
  attCNMds1ErrorsMaxIntervals INTEGER
  attCNMds1ErrorsIntervalLen INTEGER

AttCNMds1StatusEntry  
SEQUENCE    
  attCNMds1StatusIndex INTEGER
  attCNMds1LineStatus INTEGER

AttCNMds1ErrorsEntry  
SEQUENCE    
  attCNMds1ErrorsIndex INTEGER
  attCNMds1ErrorsInterval INTEGER
  attCNMds1ErrorsTimeStamp INTEGER
  attCNMds1ErrorsLocalTime DisplayString
  attCNMds1LCVs Gauge
  attCNMds1LESs Gauge
  attCNMds1LSESs Gauge
  attCNMds1CVs Gauge
  attCNMds1ESs Gauge
  attCNMds1SESs Gauge
  attCNMds1SEFSs Gauge
  attCNMds1UASs Gauge

Defined Values

att-2 1.3.6.1.4.1.74
OBJECT IDENTIFIER    

att-products 1.3.6.1.4.1.74.1
OBJECT IDENTIFIER    

att-mgmt 1.3.6.1.4.1.74.2
OBJECT IDENTIFIER    

att-cnmAgent 1.3.6.1.4.1.74.1.9
OBJECT IDENTIFIER    

att-cnm 1.3.6.1.4.1.74.2.15
OBJECT IDENTIFIER    

att-cnm-ds1 1.3.6.1.4.1.74.2.15.3
OBJECT IDENTIFIER    

attCNMds1ConfigTable 1.3.6.1.4.1.74.2.15.3.1
A list of entries containing configuration information for all DS1 interfaces managed by this system.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AttCNMds1ConfigEntry

attCNMds1ConfigEntry 1.3.6.1.4.1.74.2.15.3.1.1
An entry containing configuration information for a particular DS1 interface.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  AttCNMds1ConfigEntry  

attCNMds1ConfigIndex 1.3.6.1.4.1.74.2.15.3.1.1.1
A unique value for each DS1 interface. The interface identified by a particular value of this index is the same interface as identified by the same value of an attCNMifConfigIndex object instance.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

attCNMds1LineType 1.3.6.1.4.1.74.2.15.3.1.1.2
This variable indicates the variety of DS1 frame format supported by this interface. For SMDS, this variable will have the value ds1ANSI-ESF, denoting that this interface supports the DS1 Extended Super Frame format as specified by ANSI.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER other(1), ds1ESF(2), ds1D4(3), ds1ANSI-ESF(4), ds1G704(5), ds1G704-CRC(6)  

attCNMds1ZeroCoding 1.3.6.1.4.1.74.2.15.3.1.1.3
This variable describes the variety of zero code suppression/substitution used on the DS1 interface.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER ds1JammedBit(1), ds1B8ZS(2), ds1InvertedHDLC(3), ds1HDB3(4), ds1ZBTSI(5)  

attCNMds1ErrorsMaxIntervals 1.3.6.1.4.1.74.2.15.3.1.1.4
This variable identifies the maximum number of measurement intervals supported for the error counts maintained by this DS1 interface in the attCNMds1ErrorsTable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

attCNMds1ErrorsIntervalLen 1.3.6.1.4.1.74.2.15.3.1.1.5
This variable identifies the number of seconds that make up one complete measurement interval for the error counts maintained by this DS1 interface in the attCNMds1ErrorsTable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

attCNMds1StatusTable 1.3.6.1.4.1.74.2.15.3.2
A list of entries containing status information for all DS1 interfaces managed by this system.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AttCNMds1StatusEntry

attCNMds1StatusEntry 1.3.6.1.4.1.74.2.15.3.2.1
An entry containing status information for a particular DS1 interface.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  AttCNMds1StatusEntry  

attCNMds1StatusIndex 1.3.6.1.4.1.74.2.15.3.2.1.1
A unique value for each DS1 interface. The interface identified by a particular value of this index is the same interface as identified by the same value of an attCNMifConfigIndex object instance.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

attCNMds1LineStatus 1.3.6.1.4.1.74.2.15.3.2.1.2
This variable indicates the most Line Status of this interface. This object is a bit map represented as a sum, therefore, it can represent multiple failures (alarms) simultaneously. The various bit positions are: 1 No Alarm Present 2 Yellow Alarm 4 Near End Alarm-Indication-Signal (AIS) 8 Near End Loss-Of-Frame (LOF) 16 Near End Loss-Of-Signal (LOS) For example, for an interface that has LOF and LOS outstanding, this object will have a value of 24.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

attCNMds1ErrorsTable 1.3.6.1.4.1.74.2.15.3.3
A list of entries containing protocol error counts, maintained during the specified measurement interval, for all DS1 interfaces managed by this system.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    AttCNMds1ErrorsEntry

attCNMds1ErrorsEntry 1.3.6.1.4.1.74.2.15.3.3.1
An entry containing protocol error counts, maintained during the specified measurement interval, for a particular DS1 interface.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  AttCNMds1ErrorsEntry  

attCNMds1ErrorsIndex 1.3.6.1.4.1.74.2.15.3.3.1.1
A unique value for each DS1 interface. The interface identified by a particular value of this index is the same interface as identified by the same value of an attCNMifConfigIndex object instance.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

attCNMds1ErrorsInterval 1.3.6.1.4.1.74.2.15.3.3.1.2
This variable identifies the measurement interval number for which the measurement is provided. It is a number between 1 and XX, where 1 identifies the most recently completed measurement interval and XX is the least recently completed measurement interval. The value of XX is specified by the attCNMds1ErrorsMaxIntervals object given in the attCNMds1ConfigTable. The maximum length of each measurement interval is specified by the attCNMds1ErrorsIntervalLen object given in the attCNMds1ConfigTable.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

attCNMds1ErrorsTimeStamp 1.3.6.1.4.1.74.2.15.3.3.1.3
The time stamp corresponding to the end of the specified measurement interval, as measured in seconds from 00:00:00 UTC (Coordinated Universal Time) January 1, 1970. Any fraction is rounded up.
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

attCNMds1ErrorsLocalTime 1.3.6.1.4.1.74.2.15.3.3.1.4
The time stamp corresponding to the end of the specified measurement interval. Any fraction is rounded up. It is given as a printable ASCII string showing the local time at the end of the interval.
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString Size(0..255)  

attCNMds1LCVs 1.3.6.1.4.1.74.2.15.3.3.1.5
The counter associated with the number of Line Code Violations encountered by a DS1 interface during the specified measurement interval. A Line Code Violation is the occurrence of a received Bipolar Violation that is not part of a zero-substitution code. The Bipolar Violation Rate is generally viewed as approximating the Bit Error Rate.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

attCNMds1LESs 1.3.6.1.4.1.74.2.15.3.3.1.6
The counter associated with the number of Line Errored Seconds encountered by a DS1 interface during the specified measurement interval. A Line Errored Second is any second with at least one Line Code Violation.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

attCNMds1LSESs 1.3.6.1.4.1.74.2.15.3.3.1.7
The counter associated with the number of Line Severely Errored Seconds encountered by a DS1 interface during the specified measurement interval. A Line Severely Errored Second is any second with 16 or more Lince Code Violations monitored at the DS1 rate.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

attCNMds1CVs 1.3.6.1.4.1.74.2.15.3.3.1.8
The counter associated with the number of Code Violations encountered by a DS1 interface during the specified measurement interval. A Code Violation is the occurrence of a received CRC-6 code that is not identical to the corresponding locally-calculated code.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

attCNMds1ESs 1.3.6.1.4.1.74.2.15.3.3.1.9
The counter associated with the number of Errored Seconds encountered by a DS1 interface during the specified measurement interval. An Errored Second is any second with at least one Code Violation.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

attCNMds1SESs 1.3.6.1.4.1.74.2.15.3.3.1.10
The counter associated with the number of Severely Errored Seconds encountered by a DS1 interface during the specified measurement interval. A Severely Errored Second is any second with 15 or more Code Violations monitored at the DS1 rate.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

attCNMds1SEFSs 1.3.6.1.4.1.74.2.15.3.3.1.11
The counter associated with the number of Severely Errored Framing Seconds encountered by a DS1 interface during the specified measurement interval. A Severely Errored Framing Second is any second during which one or more Severely Errored Framing (SEF) events occurred.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge  

attCNMds1UASs 1.3.6.1.4.1.74.2.15.3.3.1.12
The counter associated with the number of Unavailable Seconds encountered by a DS1 interface during the specified measurement interval. An Unavailable Second is any second during which the DS1 interface was unavailable to offer service.
Status: mandatory Access: read-only
OBJECT-TYPE    
  Gauge