ASCEND-MIBSYS1-MIB

File: ASCEND-MIBSYS1-MIB.mib (23493 bytes)

Imported modules

ASCEND-MIB RFC1155-SMI RFC-1212

Imported symbols

configuration IpAddress OBJECT-TYPE

Defined Types

DisplayString  
OCTET STRING    

MibsystemProfileEntry  
SEQUENCE    
  systemProfile-Index-o INTEGER
  systemProfile-Name DisplayString
  systemProfile-Contact DisplayString
  systemProfile-Location DisplayString
  systemProfile-TermRate INTEGER
  systemProfile-Console INTEGER
  systemProfile-ConsoleSecurity INTEGER
  systemProfile-SystemRmtMgmt INTEGER
  systemProfile-SubAddressMode INTEGER
  systemProfile-SerialSubaddress INTEGER
  systemProfile-LanSubaddress INTEGER
  systemProfile-DmSubaddress INTEGER
  systemProfile-V110Subaddress INTEGER
  systemProfile-UseTrunkGroups INTEGER
  systemProfile-NumDigitsTrunkGroups INTEGER
  systemProfile-AutoLogout INTEGER
  systemProfile-IdleLogout INTEGER
  systemProfile-P50SwitchUsage INTEGER
  systemProfile-oDS0MinRst INTEGER
  systemProfile-MaxSystemDS0Mins INTEGER
  systemProfile-MaxDialoutTime INTEGER
  systemProfile-ParallelDialing INTEGER
  systemProfile-SingleFileIncoming INTEGER
  systemProfile-DelayDualPortDialing INTEGER
  systemProfile-EditNumber DisplayString
  systemProfile-AnalogEncoding INTEGER
  systemProfile-SessionidBase INTEGER
  systemProfile-TOnline INTEGER
  systemProfile-TOnlineMostAvailChan INTEGER
  systemProfile-T302Timer INTEGER
  systemProfile-CallRoutingSortMethod INTEGER
  systemProfile-DigitalCallRoutingSortMethod INTEGER
  systemProfile-ExactMatchCallRouting INTEGER
  systemProfile-ShelfControllerType INTEGER
  systemProfile-MasterShelfController INTEGER
  systemProfile-NewNasPortIdFormat INTEGER
  systemProfile-NasPortFormat INTEGER
  systemProfile-ModemPriTypeOfNumber INTEGER
  systemProfile-ModemPriNumberingPlanId INTEGER
  systemProfile-WanInterface INTEGER
  systemProfile-PermConnUpdMode INTEGER
  systemProfile-UserstatFormat DisplayString
  systemProfile-ControlBusType INTEGER
  systemProfile-BootSrVersion DisplayString
  systemProfile-SysModemProfile-oATAnswerString DisplayString
  systemProfile-CallByCall INTEGER
  systemProfile-Country INTEGER
  systemProfile-PotsDigitTimeout INTEGER
  systemProfile-System8kClock INTEGER
  systemProfile-SupportDbcs INTEGER
  systemProfile-IncCallDistrib INTEGER
  systemProfile-IgnoreLineup INTEGER
  systemProfile-JamFileComponents-JamFile1 DisplayString
  systemProfile-JamFileComponents-JamFile2 DisplayString
  systemProfile-JamFileComponents-JamFile3 DisplayString
  systemProfile-JamFileComponents-JamFile4 DisplayString
  systemProfile-JamFileComponents-JamFile5 DisplayString
  systemProfile-JamFileComponents-JamFile6 DisplayString
  systemProfile-Action-o INTEGER

MibsystemProfile-StatusNumberEntry  
SEQUENCE    
  systemProfile-StatusNumber-Index-o INTEGER
  systemProfile-StatusNumber-Index1-o INTEGER
  systemProfile-StatusNumber DisplayString

Defined Values

mibsystemProfile 1.3.6.1.4.1.529.23.125
OBJECT IDENTIFIER    

mibsystemProfileTable 1.3.6.1.4.1.529.23.125.1
A list of mibsystemProfile profile entries.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MibsystemProfileEntry

mibsystemProfileEntry 1.3.6.1.4.1.529.23.125.1.1
A mibsystemProfile entry containing objects that maps to the parameters of mibsystemProfile profile.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MibsystemProfileEntry  

systemProfile-Index-o 1.3.6.1.4.1.529.23.125.1.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

systemProfile-Name 1.3.6.1.4.1.529.23.125.1.1.2
The name of the system given by the user, a standard null terminated ASCII string.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

systemProfile-Contact 1.3.6.1.4.1.529.23.125.1.1.3
The name of the contact for this device. SNMP readable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

systemProfile-Location 1.3.6.1.4.1.529.23.125.1.1.4
The location of this device. SNMP readable.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

systemProfile-TermRate 1.3.6.1.4.1.529.23.125.1.1.5
The bit rate of the management terminal port, as given above.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER n-300Bps(1), n-1200Bps(2), n-2400Bps(3), n-4800Bps(4), n-9600Bps(5), n-19200Bps(6), n-38400Bps(7), n-57600Bps(8), n-115200Bps(9)  

systemProfile-Console 1.3.6.1.4.1.529.23.125.1.1.6
A MenuType specifying the type of interface to use on the console port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER standard(1), limited(2), mif(3)  

systemProfile-ConsoleSecurity 1.3.6.1.4.1.529.23.125.1.1.7
Serial console security for the control port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER consoleSecurityNone(1), consoleSecurityProfile(2), consoleSecurityAuthSetting(3)  

systemProfile-SystemRmtMgmt 1.3.6.1.4.1.529.23.125.1.1.8
Set true if this system allows remote management.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

systemProfile-SubAddressMode 1.3.6.1.4.1.529.23.125.1.1.9
Selects system wide sub-address support. See mibglob.mdf for details.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noSubaddress(1), routingSubaddress(2), termselSubaddress(3)  

systemProfile-SerialSubaddress 1.3.6.1.4.1.529.23.125.1.1.10
sub-address assigned to serial port connections.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

systemProfile-LanSubaddress 1.3.6.1.4.1.529.23.125.1.1.11
sub-address assigned to sync lan connections.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

systemProfile-DmSubaddress 1.3.6.1.4.1.529.23.125.1.1.12
sub-address assigned to digital modem connections.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

systemProfile-V110Subaddress 1.3.6.1.4.1.529.23.125.1.1.13
sub-address assigned to V.110 rate adaption connections
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

systemProfile-UseTrunkGroups 1.3.6.1.4.1.529.23.125.1.1.14
Enables TrunkGroups for all network lines.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

systemProfile-NumDigitsTrunkGroups 1.3.6.1.4.1.529.23.125.1.1.15
Specify number of digits TrunkGroups support.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

systemProfile-AutoLogout 1.3.6.1.4.1.529.23.125.1.1.16
When TRUE select the default security profile on loss of CD/DTR from the main console port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

systemProfile-IdleLogout 1.3.6.1.4.1.529.23.125.1.1.17
When non-zero select the default security profile after this value of minutes with no keyboard activity.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

systemProfile-P50SwitchUsage 1.3.6.1.4.1.529.23.125.1.1.18
What the P50 switch does.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER switchUnused(1), switchSerialWan(2), switchNumberOfUses(3)  

systemProfile-oDS0MinRst 1.3.6.1.4.1.529.23.125.1.1.19
Has three choices: Off, 24Hr or Monthly. When enabled, the following maxSystemDS0Mins is the high water mark at which all switched connections originating on the system will be taken down.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), daily(2), monthly(3)  

systemProfile-MaxSystemDS0Mins 1.3.6.1.4.1.529.23.125.1.1.20
Sets the high water billing mark at which all originating switched connections are brought down.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

systemProfile-MaxDialoutTime 1.3.6.1.4.1.529.23.125.1.1.21
The max time in Sec, system will wait for Call Setup Complete
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

systemProfile-ParallelDialing 1.3.6.1.4.1.529.23.125.1.1.22
The number of simultaneous DS0 channel outdials the switch allows.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

systemProfile-SingleFileIncoming 1.3.6.1.4.1.529.23.125.1.1.23
Should the calls be treated as a single-file list, or in parallel. PictureTel wants parallel others want single-file.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

systemProfile-DelayDualPortDialing 1.3.6.1.4.1.529.23.125.1.1.24
TRUE if we should delay between dual port calls, FALSE if they should be placed at the same time.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

systemProfile-EditNumber 1.3.6.1.4.1.529.23.125.1.1.25
The menu number of the default edit screen.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

systemProfile-AnalogEncoding 1.3.6.1.4.1.529.23.125.1.1.26
Sets the encoding standard for digitized analog data to either u-Law or A-Law. Universally sets all codecs on the unit to the value selected. Defaults to u-Law for T1, A-Law for E1 interfaces.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER uLaw(1), aLaw(2)  

systemProfile-SessionidBase 1.3.6.1.4.1.529.23.125.1.1.27
The base session ID value
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

systemProfile-TOnline 1.3.6.1.4.1.529.23.125.1.1.28
TRUE if we should route calls to T-Online, FALSE if not.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

systemProfile-TOnlineMostAvailChan 1.3.6.1.4.1.529.23.125.1.1.29
TRUE if T-Online calls are to be routed to NT line with the most available B-channels FALSE if it is based on circular basis.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

systemProfile-T302Timer 1.3.6.1.4.1.529.23.125.1.1.30
Number of milliseconds to wait for additional called number information elements for an incoming T-Online call. Defaults to 1500.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

systemProfile-CallRoutingSortMethod 1.3.6.1.4.1.529.23.125.1.1.31
How to sort the Call Routing table for analog calls.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER itemFirst(1), slotFirst(2)  

systemProfile-DigitalCallRoutingSortMethod 1.3.6.1.4.1.529.23.125.1.1.32
How to sort the Call Routing table for digital calls.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER itemFirst(1), slotFirst(2)  

systemProfile-ExactMatchCallRouting 1.3.6.1.4.1.529.23.125.1.1.33
If yes, the system will search for an exact match of call-route profile parameters when selecting devices. Wildcard matches will be accepted only after all 4 quadrants have been searched. (APX only)
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

systemProfile-ShelfControllerType 1.3.6.1.4.1.529.23.125.1.1.34
Used to define the role of this controller in a single-shelf or multi-shelf system. Note: This variable is not applicable to the APX 8000.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER standalone(1), master(2), slave(3)  

systemProfile-MasterShelfController 1.3.6.1.4.1.529.23.125.1.1.35
Master shelf controller number. This attribute exists only when the shelf-controller-type is SLAVE. Note: This variable is not applicable to the APX 8000.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

systemProfile-NewNasPortIdFormat 1.3.6.1.4.1.529.23.125.1.1.36
Field is deprecated; use the 'nas-port-format' field to specify the NAS port format. Will be used only if 'nas-port-format' is set to 'not-applicable'. TRUE if new NAS port ID format is used, FALSE if old NAS Port ID is used. On the TNT product family the new NAS port ID format is used by default. The old format cannot be used for multi-shelf systems or if any line cards are in a slot greater than the twelfth position.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

systemProfile-NasPortFormat 1.3.6.1.4.1.529.23.125.1.1.59
Specifies NAS-Port-Format used to calculate the NAS-Port-ID. When set to 'not-applicable', indicates that the NAS Port Format is determined by the settings in the 'new-nas-port-id-format' field. Defaults to 'not-applicable'.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER notApplicable(1), n-2455(2), n-655(3), n-122(4), n-1233(5)  

systemProfile-ModemPriTypeOfNumber 1.3.6.1.4.1.529.23.125.1.1.37
PRI Called Party element's Type-Of-Number value for outgoing modem calls.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

systemProfile-ModemPriNumberingPlanId 1.3.6.1.4.1.529.23.125.1.1.38
PRI Called Party element's Numbering-Plan-ID value for outgoing modem calls.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

systemProfile-WanInterface 1.3.6.1.4.1.529.23.125.1.1.39
Sets the type of WAN interface supported: T1-CSU or Serial WAN.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER wanT1(1), wanSwan(2)  

systemProfile-PermConnUpdMode 1.3.6.1.4.1.529.23.125.1.1.40
Enables nonintrusive remote update of permanent connections' configurations. 'Changed' means that only changed connections will be torn down and reestablished, 'All' means all existing permanent connections will be turn down and then reestablished only if they are fetched from the RADIUS server again
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER all(1), changed(2)  

systemProfile-UserstatFormat 1.3.6.1.4.1.529.23.125.1.1.41
Defines the output format of the session listing command 'userstat' and the remote user information protocol 'finger'. The following special characters will be converted to their values for each listed session. The width of each field is indicated in []. %i [10] SessionID, Unique ID assigned to the session. %l [10] Line/Chan, Physical address (shelf.slot.line/chan). %s [11] Slot:Item, shelf:slot:item/logical-item of the host port. %r [11] Tx/Rx Rate, Transmit and receive rates. %d [ 3] Svc, A three-letter code showing the type of service. %a [15] Address, IP address. %u [14] Username, Connection profile name. %c [10] ConnTime, Ammount of time connected in hours:minutes:seconds. %t [10] IdleTime, Ammount of time idle in hours:minutes:seconds. %n [24] Dialed#, Number dialed if known. %f [24] Calling#, Number calling from if known. For example set userstat-format = '%i %l %s %r %d %a %u %c %t %n' would set the format to the factory default value.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

systemProfile-ControlBusType 1.3.6.1.4.1.529.23.125.1.1.42
How to send control bus messages. This attribute exists only when the shelf-controller-type is not SLAVE.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER dpram(1), pbus(2)  

systemProfile-BootSrVersion 1.3.6.1.4.1.529.23.125.1.1.43
Place for tntsrb, the shelf controller boot loader, to provide its version. Boot loader updates the field with its version on every system reset
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

systemProfile-SysModemProfile-oATAnswerString 1.3.6.1.4.1.529.23.125.1.1.44
Allows the user to enter any additional AT commands in the modem answer string.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

systemProfile-CallByCall 1.3.6.1.4.1.529.23.125.1.1.45
PRI Called Party element's Network Specific Facility for Call-by-Call.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

systemProfile-Country 1.3.6.1.4.1.529.23.125.1.1.46
Country in which the system is located.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER argentina(2), australia(3), belgium(4), brazil(23), china(5), costaRica(6), finland(7), france(8), germany(9), hongKong(10), italy(11), japan(12), korea(13), mexico(14), netherlands(15), newZealand(16), singapore(17), spain(18), sweden(19), switzerland(20), uk(21), us(22)  

systemProfile-PotsDigitTimeout 1.3.6.1.4.1.529.23.125.1.1.47
POTS interdigit timeout.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

systemProfile-System8kClock 1.3.6.1.4.1.529.23.125.1.1.48
8KHz clock source for Stinger-10.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER controller(2), limOrTrunkModule(3), bits(4), ami8k(5)  

systemProfile-SupportDbcs 1.3.6.1.4.1.529.23.125.1.1.49
TRUE if we should support DBCS character set, FALSE if not.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

systemProfile-IncCallDistrib 1.3.6.1.4.1.529.23.125.1.1.50
Route incoming calls to first available valid port or the least used among a set of ports.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER firstAvailable(2), fairShare(3)  

systemProfile-IgnoreLineup 1.3.6.1.4.1.529.23.125.1.1.51
If ignore-lineup in line config profile is set to SYSTEM DEFINED, then this will take precedence.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

systemProfile-JamFileComponents-JamFile1 1.3.6.1.4.1.529.23.125.1.1.53
File name of the first JAM file's component
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

systemProfile-JamFileComponents-JamFile2 1.3.6.1.4.1.529.23.125.1.1.54
File name of the second JAM file's component
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

systemProfile-JamFileComponents-JamFile3 1.3.6.1.4.1.529.23.125.1.1.55
File name of the third JAM file's component
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

systemProfile-JamFileComponents-JamFile4 1.3.6.1.4.1.529.23.125.1.1.56
File name of the fourth JAM file's component
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

systemProfile-JamFileComponents-JamFile5 1.3.6.1.4.1.529.23.125.1.1.57
File name of the fifth JAM file's component
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

systemProfile-JamFileComponents-JamFile6 1.3.6.1.4.1.529.23.125.1.1.58
File name of the sixth JAM file's component
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

systemProfile-Action-o 1.3.6.1.4.1.529.23.125.1.1.52
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noAction(1), createProfile(2), deleteProfile(3)  

mibsystemProfile-StatusNumberTable 1.3.6.1.4.1.529.23.125.2
A list of mibsystemProfile__status_number profile entries.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MibsystemProfile-StatusNumberEntry

mibsystemProfile-StatusNumberEntry 1.3.6.1.4.1.529.23.125.2.1
A mibsystemProfile__status_number entry containing objects that maps to the parameters of mibsystemProfile__status_number profile.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MibsystemProfile-StatusNumberEntry  

systemProfile-StatusNumber-Index-o 1.3.6.1.4.1.529.23.125.2.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

systemProfile-StatusNumber-Index1-o 1.3.6.1.4.1.529.23.125.2.1.2
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

systemProfile-StatusNumber 1.3.6.1.4.1.529.23.125.2.1.3
An array of status screen number entries used to specify the default status screen layout.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString