ASCEND-MIBSTATICSLOT-MIB

File: ASCEND-MIBSTATICSLOT-MIB.mib (6789 bytes)

Imported modules

ASCEND-MIB RFC1155-SMI RFC-1212

Imported symbols

configuration IpAddress OBJECT-TYPE

Defined Types

DisplayString  
OCTET STRING    

MibmibProfSlotStaticEntry  
SEQUENCE    
  mibProfSlotStatic-Shelf-o INTEGER
  mibProfSlotStatic-Slot-o INTEGER
  mibProfSlotStatic-Item-o INTEGER
  mibProfSlotStatic-Name DisplayString
  mibProfSlotStatic-PhysicalAddress-Shelf INTEGER
  mibProfSlotStatic-PhysicalAddress-Slot INTEGER
  mibProfSlotStatic-PhysicalAddress-ItemNumber INTEGER
  mibProfSlotStatic-AtmParameters-IncomingPriority INTEGER
  mibProfSlotStatic-InterfaceType INTEGER
  mibProfSlotStatic-Action-o INTEGER

Defined Values

mibmibProfSlotStatic 1.3.6.1.4.1.529.23.31
OBJECT IDENTIFIER    

mibmibProfSlotStaticTable 1.3.6.1.4.1.529.23.31.1
A list of mibmibProfSlotStatic profile entries.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MibmibProfSlotStaticEntry

mibmibProfSlotStaticEntry 1.3.6.1.4.1.529.23.31.1.1
A mibmibProfSlotStatic entry containing objects that maps to the parameters of mibmibProfSlotStatic profile.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MibmibProfSlotStaticEntry  

mibProfSlotStatic-Shelf-o 1.3.6.1.4.1.529.23.31.1.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mibProfSlotStatic-Slot-o 1.3.6.1.4.1.529.23.31.1.1.2
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mibProfSlotStatic-Item-o 1.3.6.1.4.1.529.23.31.1.1.3
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

mibProfSlotStatic-Name 1.3.6.1.4.1.529.23.31.1.1.4
For future use. The current design does not use this name attribute but instead references a LIM or CM slot by its profile index; we may in the future support referencing a LIM or CM slot by its name as well as by its physical address. This name attribute consists of a null-terminated ASCII string; is read-only; and defaults to the ASCII form of this LIM or CM slot physical address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

mibProfSlotStatic-PhysicalAddress-Shelf 1.3.6.1.4.1.529.23.31.1.1.5
The number of the shelf that the addressed physical device resides on.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER anyShelf(1), shelf1(2), shelf2(3), shelf3(4), shelf4(5), shelf5(6), shelf6(7), shelf7(8), shelf8(9), shelf9(10)  

mibProfSlotStatic-PhysicalAddress-Slot 1.3.6.1.4.1.529.23.31.1.1.6
The number of the slot that the addressed physical device resides on.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER anySlot(1), slot1(2), slot2(3), slot3(4), slot4(5), slot5(6), slot6(7), slot7(8), slot8(9), slot9(10), slot10(11), slot11(12), slot12(13), slot13(14), slot14(15), slot15(16), slot16(17), slot17(18), slot18(19), slot19(20), slot20(21), slot21(22), slot22(23), slot23(24), slot24(25), slot25(26), slot26(27), slot27(28), slot28(29), slot29(30), slot30(31), slot31(32), slot32(33), slot33(34), slot34(35), slot35(36), slot36(37), slot37(38), slot38(39), slot39(40), slot40(41), aLim(55), bLim(56), cLim(57), dLim(58), leftController(49), rightController(50), controller(42), firstControlModule(53), secondControlModule(54), trunkModule1(45), trunkModule2(46), controlModule(51), slotPrimary(59)  

mibProfSlotStatic-PhysicalAddress-ItemNumber 1.3.6.1.4.1.529.23.31.1.1.7
A number that specifies an addressable entity within the context of shelf and slot.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

mibProfSlotStatic-AtmParameters-IncomingPriority 1.3.6.1.4.1.529.23.31.1.1.8
Specifies the relative priority of ATM cells incoming from this LIM or CM slot. A slot's incoming-priority is used to select the appropriate outgoing queue that is associated with the outgoing port from the internal ATM cell processing engine. All ports on this slot and all ATM service categories share the same incoming-priority. An outgoing port (from the internal ATM cell processing engine) can have multiple queues associated with a given QoS. The incoming-priority is used to select which queue to use among all the queues associated with the given QoS.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER lowPriority(1), highPriority(2)  

mibProfSlotStatic-InterfaceType 1.3.6.1.4.1.529.23.31.1.1.10
Modifying this field does not effect non-hdsl/shdsl cards. All slots are set to 'default' at initialization. g.shdsl is used as 'default' for slots with hdsl2/g.shdsl cards. non-hdsl/shdsl slots default into their card types. The HDSL2 and SHDSL slot cards support HDSL2 or G.SHDSL modem technologies.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER default(1), gShdsl(2), hdsl2(3)  

mibProfSlotStatic-Action-o 1.3.6.1.4.1.529.23.31.1.1.9
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noAction(1), createProfile(2), deleteProfile(3)