ASCEND-MIBSHDSLNET-MIB

File: ASCEND-MIBSHDSLNET-MIB.mib (20090 bytes)

Imported modules

ASCEND-MIB RFC1155-SMI RFC-1212

Imported symbols

configuration IpAddress OBJECT-TYPE

Defined Types

DisplayString  
OCTET STRING    

MibshdslNetworkProfileEntry  
SEQUENCE    
  shdslNetworkProfile-Shelf-o INTEGER
  shdslNetworkProfile-Slot-o INTEGER
  shdslNetworkProfile-Item-o INTEGER
  shdslNetworkProfile-Name DisplayString
  shdslNetworkProfile-PhysicalAddress-Shelf INTEGER
  shdslNetworkProfile-PhysicalAddress-Slot INTEGER
  shdslNetworkProfile-PhysicalAddress-ItemNumber INTEGER
  shdslNetworkProfile-Enabled INTEGER
  shdslNetworkProfile-SparingMode INTEGER
  shdslNetworkProfile-IgnoreLineup INTEGER
  shdslNetworkProfile-ProfileNumber INTEGER
  shdslNetworkProfile-LineConfig-TrunkGroup INTEGER
  shdslNetworkProfile-LineConfig-NailedGroup INTEGER
  shdslNetworkProfile-LineConfig-VpSwitchingVpi INTEGER
  shdslNetworkProfile-LineConfig-RoutePort-SlotNumber-SlotNumber INTEGER
  shdslNetworkProfile-LineConfig-RoutePort-SlotNumber-ShelfNumber INTEGER
  shdslNetworkProfile-LineConfig-RoutePort-RelativePortNumber-RelativePortNumber INTEGER
  shdslNetworkProfile-LineConfig-Activation INTEGER
  shdslNetworkProfile-LineConfig-CallRouteInfo-Shelf INTEGER
  shdslNetworkProfile-LineConfig-CallRouteInfo-Slot INTEGER
  shdslNetworkProfile-LineConfig-CallRouteInfo-ItemNumber INTEGER
  shdslNetworkProfile-LineConfig-UnitType INTEGER
  shdslNetworkProfile-LineConfig-NtrEnabled INTEGER
  shdslNetworkProfile-LineConfig-ClockSource INTEGER
  shdslNetworkProfile-LineConfig-ClockPriority INTEGER
  shdslNetworkProfile-LineConfig-LoopBack INTEGER
  shdslNetworkProfile-LineConfig-Margin INTEGER
  shdslNetworkProfile-LineConfig-SnextMargin INTEGER
  shdslNetworkProfile-LineConfig-RateMode INTEGER
  shdslNetworkProfile-LineConfig-MinRate INTEGER
  shdslNetworkProfile-LineConfig-MaxRate INTEGER
  shdslNetworkProfile-LineConfig-GshdslStandardNetworkType INTEGER
  shdslNetworkProfile-LineConfig-AnnexbAnfpEnabled INTEGER
  shdslNetworkProfile-LineConfig-GshdslPsdType INTEGER
  shdslNetworkProfile-LineConfig-MasterBindingPort INTEGER
  shdslNetworkProfile-Action-o INTEGER

Defined Values

mibshdslNetworkProfile 1.3.6.1.4.1.529.23.147
OBJECT IDENTIFIER    

mibshdslNetworkProfileTable 1.3.6.1.4.1.529.23.147.1
A list of mibshdslNetworkProfile profile entries.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MibshdslNetworkProfileEntry

mibshdslNetworkProfileEntry 1.3.6.1.4.1.529.23.147.1.1
A mibshdslNetworkProfile entry containing objects that maps to the parameters of mibshdslNetworkProfile profile.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MibshdslNetworkProfileEntry  

shdslNetworkProfile-Shelf-o 1.3.6.1.4.1.529.23.147.1.1.1
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

shdslNetworkProfile-Slot-o 1.3.6.1.4.1.529.23.147.1.1.2
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

shdslNetworkProfile-Item-o 1.3.6.1.4.1.529.23.147.1.1.3
Tok_String
Status: mandatory Access: read-only
OBJECT-TYPE    
  INTEGER  

shdslNetworkProfile-Name 1.3.6.1.4.1.529.23.147.1.1.4
For future use. The current design does not use the name field but instead references Shdsl lines by the physical address; we may in the future support referencing Shdsl lines by name as well as by address. The name consists of a null terminated ascii string supplied by the user; it defaults to the ascii form of the Shdsl line physical address.
Status: mandatory Access: read-write
OBJECT-TYPE    
  DisplayString  

shdslNetworkProfile-PhysicalAddress-Shelf 1.3.6.1.4.1.529.23.147.1.1.5
The number of the shelf that the addressed physical device resides on.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER anyShelf(1), shelf1(2), shelf2(3), shelf3(4), shelf4(5), shelf5(6), shelf6(7), shelf7(8), shelf8(9), shelf9(10)  

shdslNetworkProfile-PhysicalAddress-Slot 1.3.6.1.4.1.529.23.147.1.1.6
The number of the slot that the addressed physical device resides on.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER anySlot(1), slot1(2), slot2(3), slot3(4), slot4(5), slot5(6), slot6(7), slot7(8), slot8(9), slot9(10), slot10(11), slot11(12), slot12(13), slot13(14), slot14(15), slot15(16), slot16(17), slot17(18), slot18(19), slot19(20), slot20(21), slot21(22), slot22(23), slot23(24), slot24(25), slot25(26), slot26(27), slot27(28), slot28(29), slot29(30), slot30(31), slot31(32), slot32(33), slot33(34), slot34(35), slot35(36), slot36(37), slot37(38), slot38(39), slot39(40), slot40(41), aLim(55), bLim(56), cLim(57), dLim(58), leftController(49), rightController(50), controller(42), firstControlModule(53), secondControlModule(54), trunkModule1(45), trunkModule2(46), controlModule(51), slotPrimary(59)  

shdslNetworkProfile-PhysicalAddress-ItemNumber 1.3.6.1.4.1.529.23.147.1.1.7
A number that specifies an addressable entity within the context of shelf and slot.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

shdslNetworkProfile-Enabled 1.3.6.1.4.1.529.23.147.1.1.8
TRUE if the line is enabled, otherwise FALSE.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

shdslNetworkProfile-SparingMode 1.3.6.1.4.1.529.23.147.1.1.9
Port sparing operational mode for this port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER inactive(1), manual(2), automatic(3)  

shdslNetworkProfile-IgnoreLineup 1.3.6.1.4.1.529.23.147.1.1.10
Ignore line up value for this port.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER systemDefined(1), no(2), yes(3)  

shdslNetworkProfile-ProfileNumber 1.3.6.1.4.1.529.23.147.1.1.11
For potential backwards compatibility. The current design consists of one line profile numbered 0.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

shdslNetworkProfile-LineConfig-TrunkGroup 1.3.6.1.4.1.529.23.147.1.1.12
The trunk group to which this line is assigned. 0 means this line is not part of a trunk group.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

shdslNetworkProfile-LineConfig-NailedGroup 1.3.6.1.4.1.529.23.147.1.1.13
A number that identifies the set of lines that makes up a nailed group. 0 means this line is not part of a nailed group.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

shdslNetworkProfile-LineConfig-VpSwitchingVpi 1.3.6.1.4.1.529.23.147.1.1.14
The Vpi to be used for the VP switching. Rest of the valid VPIs in valid vpi-vci-range will be used for the VC switching. Changes in this range will take effect immediately. THE USER SHOULD BE VERY CAREFUL WHILE CHANGING THIS VALUE BECAUSE ALL CONNECTIONS ON THE LIM WHERE THIS PORT BELONGS WILL BE DROPPED IN ORDER TO MAKE THIS NEW VALUE EFFECTIVE IMMEDIATELY.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

shdslNetworkProfile-LineConfig-RoutePort-SlotNumber-SlotNumber 1.3.6.1.4.1.529.23.147.1.1.15
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

shdslNetworkProfile-LineConfig-RoutePort-SlotNumber-ShelfNumber 1.3.6.1.4.1.529.23.147.1.1.16
TNT is a multi shelf system. To minimise the changes required to existing code the shelf number is added to this structure as it will almost always be needed when a slot number is needed.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

shdslNetworkProfile-LineConfig-RoutePort-RelativePortNumber-RelativePortNumber 1.3.6.1.4.1.529.23.147.1.1.17
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

shdslNetworkProfile-LineConfig-Activation 1.3.6.1.4.1.529.23.147.1.1.18
Line activation mode.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER static(1), dsrActive(2), dcdDsrActive(3)  

shdslNetworkProfile-LineConfig-CallRouteInfo-Shelf 1.3.6.1.4.1.529.23.147.1.1.19
The number of the shelf that the addressed physical device resides on.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER anyShelf(1), shelf1(2), shelf2(3), shelf3(4), shelf4(5), shelf5(6), shelf6(7), shelf7(8), shelf8(9), shelf9(10)  

shdslNetworkProfile-LineConfig-CallRouteInfo-Slot 1.3.6.1.4.1.529.23.147.1.1.20
The number of the slot that the addressed physical device resides on.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER anySlot(1), slot1(2), slot2(3), slot3(4), slot4(5), slot5(6), slot6(7), slot7(8), slot8(9), slot9(10), slot10(11), slot11(12), slot12(13), slot13(14), slot14(15), slot15(16), slot16(17), slot17(18), slot18(19), slot19(20), slot20(21), slot21(22), slot22(23), slot23(24), slot24(25), slot25(26), slot26(27), slot27(28), slot28(29), slot29(30), slot30(31), slot31(32), slot32(33), slot33(34), slot34(35), slot35(36), slot36(37), slot37(38), slot38(39), slot39(40), slot40(41), aLim(55), bLim(56), cLim(57), dLim(58), leftController(49), rightController(50), controller(42), firstControlModule(53), secondControlModule(54), trunkModule1(45), trunkModule2(46), controlModule(51), slotPrimary(59)  

shdslNetworkProfile-LineConfig-CallRouteInfo-ItemNumber 1.3.6.1.4.1.529.23.147.1.1.21
A number that specifies an addressable entity within the context of shelf and slot.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

shdslNetworkProfile-LineConfig-UnitType 1.3.6.1.4.1.529.23.147.1.1.22
The Unit Type defines if a line is acting as either a Central Office (COE) or Customer Premise Equipment (CPE). Note that the remote unit needs to be configured opposite to this configureation.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER coe(1), cpe(2)  

shdslNetworkProfile-LineConfig-NtrEnabled 1.3.6.1.4.1.529.23.147.1.1.23
TRUE if NTR functionality is enabled, otherwise FALSE. If the unit-type is COE, it will take the system clock as the input when NTR is enabled and allow the remote CPE port to recover the clock. If the unit-type is CPE, it will allow the port to possibly output the recovered clock as the system clock (if elected, see clock-source and clock-priority fields) when NTR is enabled.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

shdslNetworkProfile-LineConfig-ClockSource 1.3.6.1.4.1.529.23.147.1.1.24
Determine whether the 8KHz clock from the SHDSL line (unit-type has to be CPE and ntr-enabled has to be yes) is eligible to be used as the 8KHz system clock source.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER eligible(1), notEligible(2)  

shdslNetworkProfile-LineConfig-ClockPriority 1.3.6.1.4.1.529.23.147.1.1.25
Clock priority assigned to the SHDSL line. Used to select a particular SHDSL line as the 8KHz system clock source.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER highPriority(2), middlePriority(3), lowPriority(4)  

shdslNetworkProfile-LineConfig-LoopBack 1.3.6.1.4.1.529.23.147.1.1.26
Configuration of different modem loopbacks.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER none(1), analog(2), digital(3)  

shdslNetworkProfile-LineConfig-Margin 1.3.6.1.4.1.529.23.147.1.1.27
Selects a margin range between the signal to noise floor.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER n-0db(1), n-1db(2), n-2db(3), n-3db(4), n-4db(5), n-5db(6), n-6db(7), n-7db(8), n-8db(9), n-9db(10), n-10db(11), disable(17)  

shdslNetworkProfile-LineConfig-SnextMargin 1.3.6.1.4.1.529.23.147.1.1.34
Selects a Snext margin range with a worst-case self next noise model given current loop insertion loss.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER n-0db(1), n-1db(2), n-2db(3), n-3db(4), n-4db(5), n-5db(6), n-6db(7), n-7db(8), n-8db(9), n-9db(10), n-10db(11), n-plus-10db(12), n-plus-9db(13), n-plus-8db(14), n-plus-7db(15), n-plus-6db(16), n-plus-5db(17), n-plus-4db(18), n-plus-3db(19), n-plus-2db(20), n-plus-1db(21), disable(22)  

shdslNetworkProfile-LineConfig-RateMode 1.3.6.1.4.1.529.23.147.1.1.28
Used for G.SHDSL technology. Selects if the modem operates in Fixed or Auto rate mode.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER fixed(1), auto(2)  

shdslNetworkProfile-LineConfig-MinRate 1.3.6.1.4.1.529.23.147.1.1.29
Used for G.SHDSL technology. When the rate-mode is set to Auto, this is the minimum rate the modem will train to.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER n-72000(72001), n-136000(136001), n-200000(200001), n-264000(264001), n-328000(328001), n-392000(392001), n-520000(520001), n-776000(776001), n-1032000(1032001), n-1160000(1160001), n-1288000(1288001), n-1544000(1544001), n-2056000(2056001), n-2312000(2312001)  

shdslNetworkProfile-LineConfig-MaxRate 1.3.6.1.4.1.529.23.147.1.1.30
Used for G.SHDSL technology. When the rate-mode is set to Auto, this is the maximum rate the modem will train to. When the rate-mode is set to Fixed, this is the only rate the mode trains to.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER n-72000(72001), n-136000(136001), n-200000(200001), n-264000(264001), n-328000(328001), n-392000(392001), n-520000(520001), n-776000(776001), n-1032000(1032001), n-1160000(1160001), n-1288000(1288001), n-1544000(1544001), n-2056000(2056001), n-2312000(2312001)  

shdslNetworkProfile-LineConfig-GshdslStandardNetworkType 1.3.6.1.4.1.529.23.147.1.1.31
Per the G.SHDSL Standard G.991.2. This parameter allows selection for the modem to operate either the North American Annex 'A' or European Annex 'B' standard network types. The setting of auto-detect is only valid for CPE to train off of COE Standard Network settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER northAmericanAnnexA(1), europeanAnnexB(2), autoDetect(3)  

shdslNetworkProfile-LineConfig-AnnexbAnfpEnabled 1.3.6.1.4.1.529.23.147.1.1.35
TRUE if Annex B ANFP functionality is enabled, otherwise FALSE. The gshdsl-standard-network-type must be set to European Annex B, and the port cannot be CPE. This field makes the modem perform in Annex B mode, but slightly differently. This is to comply with the UK ANFP requirements and pass the BTexact Technologies PSD measurement technique to meet BT approval. Only enable this field for that test specifically.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

shdslNetworkProfile-LineConfig-GshdslPsdType 1.3.6.1.4.1.529.23.147.1.1.32
Per the G.SHDSL Standard G.911.2. This parameter allows selection for the modem to output a symmetric PSD at all rates or asymmetric PSD's at fixed rates of 776kbps or 1544kbps, for Annex A networks. Annex B networks support fixed rates of 2056kbps or 2304kbps. The setting of auto-detect is only valid for CPE to train off of COE PSD settings.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER symmetric(1), asymmetric776kPsdAnnexA(4), asymmetric1544kPsdAnnexA(5), asymmetric2056kPsdAnnexB(6), asymmetric2312kPsdAnnexB(7), autoDetect(8)  

shdslNetworkProfile-LineConfig-MasterBindingPort 1.3.6.1.4.1.529.23.147.1.1.36
This parameter defines if a port is used as a master or slave for port binding purposes. Only odd ports are configured masters for the binding feature. When the master is enabled, the master port will be bound with the next even port number. Binding two SHDSL ports together will aggregate their bandwidths together. This does not apply to HDSL2 modem technology. Other line configuration rules: 1) Port rate mode needs to be Fixed. 2) The master ports max-rate and rate-mode are used for both ports. 3) Both ports need to be enabled.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

shdslNetworkProfile-Action-o 1.3.6.1.4.1.529.23.147.1.1.33
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noAction(1), createProfile(2), deleteProfile(3)