ASCEND-MIBCLTMACCESS-MIB
File:
ASCEND-MIBCLTMACCESS-MIB.mib (4652 bytes)
Imported modules
Imported symbols
Defined Types
MibcltmAccessEntry |
|
SEQUENCE |
|
|
|
|
cltmAccess-Index-o |
INTEGER |
|
|
cltmAccess-CltmSlot |
INTEGER |
|
|
cltmAccess-AccessSlot |
INTEGER |
|
|
cltmAccess-AccessPort |
INTEGER |
|
|
cltmAccess-AccessLoop |
INTEGER |
|
|
cltmAccess-AccessMode |
INTEGER |
|
|
cltmAccess-AccessTerminal |
INTEGER |
|
|
cltmAccess-ActivateAccess |
INTEGER |
|
|
cltmAccess-AccessResult |
INTEGER |
|
|
cltmAccess-Action-o |
INTEGER |
|
Defined Values
mibcltmAccessEntry |
1.3.6.1.4.1.529.23.67.1.1 |
A mibcltmAccess entry containing objects that
maps to the parameters of mibcltmAccess profile. |
Status: mandatory |
Access: not-accessible |
OBJECT-TYPE |
|
|
|
|
MibcltmAccessEntry |
|
|
cltmAccess-Index-o |
1.3.6.1.4.1.529.23.67.1.1.1 |
Tok_String |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
cltmAccess-CltmSlot |
1.3.6.1.4.1.529.23.67.1.1.2 |
Identify the CLTM slot within the system. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
anySlot(1), slot1(2), slot2(3), slot3(4), slot4(5), slot5(6), slot6(7), slot7(8), slot10(11), slot11(12), slot12(13), slot13(14), slot14(15), slot15(16), slot16(17) |
|
cltmAccess-AccessSlot |
1.3.6.1.4.1.529.23.67.1.1.3 |
Identify the slot of the copper loop to be accessed. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
anySlot(1), slot1(2), slot2(3), slot3(4), slot4(5), slot5(6), slot6(7), slot7(8), slot10(11), slot11(12), slot12(13), slot13(14), slot14(15), slot15(16), slot16(17) |
|
cltmAccess-AccessPort |
1.3.6.1.4.1.529.23.67.1.1.4 |
Identify the port of the copper loop to be accessed. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
cltmAccess-AccessLoop |
1.3.6.1.4.1.529.23.67.1.1.10 |
Identify the the copper loop to be accessed. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
|
|
cltmAccess-AccessMode |
1.3.6.1.4.1.529.23.67.1.1.5 |
The mode of the CLTM access. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
lookingOut(1), bridged(2) |
|
cltmAccess-AccessTerminal |
1.3.6.1.4.1.529.23.67.1.1.6 |
The tester terminal to access the test copper loop. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
internalTesterTerminal(1), externalTesterTerminal(2), auxiliaryTesterTerminal(3), externalLoop(4) |
|
cltmAccess-ActivateAccess |
1.3.6.1.4.1.529.23.67.1.1.7 |
Activate/Deactivate access. |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
no(1), yes(2) |
|
cltmAccess-AccessResult |
1.3.6.1.4.1.529.23.67.1.1.8 |
The result of activating the copper loop access. |
Status: mandatory |
Access: read-only |
OBJECT-TYPE |
|
|
|
|
INTEGER |
idle(1), accessActivated(2), resourceBusy(3) |
|
cltmAccess-Action-o |
1.3.6.1.4.1.529.23.67.1.1.9 |
Tok_String |
Status: mandatory |
Access: read-write |
OBJECT-TYPE |
|
|
|
|
INTEGER |
noAction(1), createProfile(2), deleteProfile(3) |
|