ASCEND-MIBALARM-MIB

File: ASCEND-MIBALARM-MIB.mib (6774 bytes)

Imported modules

ASCEND-MIB RFC1155-SMI RFC-1212

Imported symbols

configuration IpAddress OBJECT-TYPE

Defined Types

DisplayString  
OCTET STRING    

MibalarmProfileEntry  
SEQUENCE    
  alarmProfile-Name DisplayString
  alarmProfile-Enabled INTEGER
  alarmProfile-Event INTEGER
  alarmProfile-PhysicalAddress-Shelf INTEGER
  alarmProfile-PhysicalAddress-Slot INTEGER
  alarmProfile-PhysicalAddress-ItemNumber INTEGER
  alarmProfile-Action-AlarmLedMinor INTEGER
  alarmProfile-Action-AlarmLedMajor INTEGER
  alarmProfile-Action-AlarmRelayMinor INTEGER
  alarmProfile-Action-AlarmRelayMinorDuration INTEGER
  alarmProfile-Action-AlarmRelayMajor INTEGER
  alarmProfile-Action-AlarmRelayMajorDuration INTEGER
  alarmProfile-Action-o INTEGER

Defined Values

mibalarmProfile 1.3.6.1.4.1.529.23.33
OBJECT IDENTIFIER    

mibalarmProfileTable 1.3.6.1.4.1.529.23.33.1
A list of mibalarmProfile profile entries.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  SEQUENCE OF  
    MibalarmProfileEntry

mibalarmProfileEntry 1.3.6.1.4.1.529.23.33.1.1
A mibalarmProfile entry containing objects that maps to the parameters of mibalarmProfile profile.
Status: mandatory Access: not-accessible
OBJECT-TYPE    
  MibalarmProfileEntry  

alarmProfile-Name 1.3.6.1.4.1.529.23.33.1.1.1
The name consists of a null terminated ascii string supplied by the user
Status: mandatory Access: read-only
OBJECT-TYPE    
  DisplayString  

alarmProfile-Enabled 1.3.6.1.4.1.529.23.33.1.1.2
TRUE if the alarm profile is enabled, otherwise FALSE.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER no(1), yes(2)  

alarmProfile-Event 1.3.6.1.4.1.529.23.33.1.1.3
Alarm event type
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER lineStateChange(1), slotStateChange(2), primarySwitchover(3), powerFailure(4), fanFailure(5), secondaryControllerStateChange(6), inputRelayClosed(7), inputRelayOpen(8), lowTemperatureTrigger(9), highTemperatureTrigger(10), dpramCbusFailure(11)  

alarmProfile-PhysicalAddress-Shelf 1.3.6.1.4.1.529.23.33.1.1.4
The number of the shelf that the addressed physical device resides on.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER anyShelf(1), shelf1(2), shelf2(3), shelf3(4), shelf4(5), shelf5(6), shelf6(7), shelf7(8), shelf8(9), shelf9(10)  

alarmProfile-PhysicalAddress-Slot 1.3.6.1.4.1.529.23.33.1.1.5
The number of the slot that the addressed physical device resides on.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER anySlot(1), slot1(2), slot2(3), slot3(4), slot4(5), slot5(6), slot6(7), slot7(8), slot8(9), slot9(10), slot10(11), slot11(12), slot12(13), slot13(14), slot14(15), slot15(16), slot16(17), slot17(18), slot18(19), slot19(20), slot20(21), slot21(22), slot22(23), slot23(24), slot24(25), slot25(26), slot26(27), slot27(28), slot28(29), slot29(30), slot30(31), slot31(32), slot32(33), slot33(34), slot34(35), slot35(36), slot36(37), slot37(38), slot38(39), slot39(40), slot40(41), aLim(55), bLim(56), cLim(57), dLim(58), leftController(49), rightController(50), controller(42), firstControlModule(53), secondControlModule(54), trunkModule1(45), trunkModule2(46), controlModule(51), slotPrimary(59)  

alarmProfile-PhysicalAddress-ItemNumber 1.3.6.1.4.1.529.23.33.1.1.6
A number that specifies an addressable entity within the context of shelf and slot.
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

alarmProfile-Action-AlarmLedMinor 1.3.6.1.4.1.529.23.33.1.1.7
The LED that indicates a minor alarm
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

alarmProfile-Action-AlarmLedMajor 1.3.6.1.4.1.529.23.33.1.1.8
The LED that indicates a major alarm
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

alarmProfile-Action-AlarmRelayMinor 1.3.6.1.4.1.529.23.33.1.1.9
The relay that is set for a minor alarm
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

alarmProfile-Action-AlarmRelayMinorDuration 1.3.6.1.4.1.529.23.33.1.1.10
The duration in seconds for which the minor relay is set
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

alarmProfile-Action-AlarmRelayMajor 1.3.6.1.4.1.529.23.33.1.1.11
The relay that is set for a major alarm
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER off(1), on(2)  

alarmProfile-Action-AlarmRelayMajorDuration 1.3.6.1.4.1.529.23.33.1.1.12
The duration in seconds for which the major relay is set
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER  

alarmProfile-Action-o 1.3.6.1.4.1.529.23.33.1.1.13
Tok_String
Status: mandatory Access: read-write
OBJECT-TYPE    
  INTEGER noAction(1), createProfile(2), deleteProfile(3)